TEMPAGER-MIB
36 objects
No module-level DESCRIPTION found.
Imported Objects
| RFC-1212 | OBJECT-TYPE |
| RFC-1215 | TRAP-TYPE |
| RFC1155-SMI | Counter enterprises IpAddress TimeTicks |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.20916 | Nodeavtech | |||
| 1.3.6.1.4.1.20916.1 | Nodeproducts | |||
| 1.3.6.1.4.1.20916.1.1 | Nodetempager | |||
| 1.3.6.1.4.1.20916.1.1.1 | Nodealarmstart1-t4 | A alarmstart1 trap signifies that the current temperature on sensor 1 is outside the defined high or low threshold. | ||
| 1.3.6.1.4.1.20916.1.1.1 | Nodesensors | |||
| 1.3.6.1.4.1.20916.1.1.1.1 | Nodetemperature | |||
| 1.3.6.1.4.1.20916.1.1.1.1.1 | Scalartempreading1c | read-only | mandatory | Temperature Sensor 1 (Celsius) |
| 1.3.6.1.4.1.20916.1.1.1.1.2 | Scalartempreading2c | read-only | mandatory | Temperature Sensor 2 (Celsius) |
| 1.3.6.1.4.1.20916.1.1.1.1.3 | Scalartempreading3c | read-only | mandatory | Temperature Sensor 3 (Celsius) |
| 1.3.6.1.4.1.20916.1.1.1.1.4 | Scalartempreading4c | read-only | mandatory | Temperature Sensor 4 (Celsius) |
| 1.3.6.1.4.1.20916.1.1.1.1.5 | Scalartempreading1f | read-only | mandatory | Temperature Sensor 1 (Fahrenheit) |
| 1.3.6.1.4.1.20916.1.1.1.1.6 | Scalartempreading2f | read-only | mandatory | Temperature Sensor 2 (Fahrenheit) |
| 1.3.6.1.4.1.20916.1.1.1.1.7 | Scalartempreading3f | read-only | mandatory | Temperature Sensor 3 (Fahrenheit) |
| 1.3.6.1.4.1.20916.1.1.1.1.8 | Scalartempreading4f | read-only | mandatory | Temperature Sensor 4 (Fahrenheit) |
| 1.3.6.1.4.1.20916.1.1.2 | Nodetempager-snmp-trap | A tempager-snmp-trap indicates that an alarm condition has occurred on the sensor inidcated by the alarmmessage variable. | ||
| 1.3.6.1.4.1.20916.1.1.2 | Nodetraps | |||
| 1.3.6.1.4.1.20916.1.1.2.1 | Scalaralarmtemp1 | read-only | mandatory | Alarm for temperature 1 0 = temperature OK 1 = temperature too high 2 = temperature too low |
| 1.3.6.1.4.1.20916.1.1.2.2 | Scalaralarmtemp2 | read-only | mandatory | Alarm for temperature 2 0 = temperature OK 1 = temperature too high 2 = temperature too low |
| 1.3.6.1.4.1.20916.1.1.2.3 | Scalaralarmtemp3 | read-only | mandatory | Alarm for temperature 3 0 = temperature OK 1 = temperature too high 2 = temperature too low |
| 1.3.6.1.4.1.20916.1.1.2.4 | Scalaralarmtemp4 | read-only | mandatory | Alarm for temperature 4 0 = temperature OK 1 = temperature too high 2 = temperature too low |
| 1.3.6.1.4.1.20916.1.1.2.5 | Scalaralarmmessage | read-write | mandatory | Message string to send with trap messages |
| 1.3.6.1.4.1.20916.1.1.3 | Nodealarmstart2-t4 | A alarmstart2 trap signifies that the current temperature on sensor 2 is outside the defined high or low threshold. | ||
| 1.3.6.1.4.1.20916.1.1.3 | Nodethresholds | |||
| 1.3.6.1.4.1.20916.1.1.3.1 | Scalarupperlimit1 | read-only | mandatory | High temperature threshold for temperature sensor 1 |
| 1.3.6.1.4.1.20916.1.1.3.2 | Scalarlowerlimit1 | read-only | mandatory | Low temperature threshold for temperature sensor 1 |
| 1.3.6.1.4.1.20916.1.1.3.3 | Scalarupperlimit2 | read-only | mandatory | High temperature threshold for temperature sensor 2 |
| 1.3.6.1.4.1.20916.1.1.3.4 | Scalarlowerlimit2 | read-only | mandatory | Low temperature threshold for temperature sensor 2 |
| 1.3.6.1.4.1.20916.1.1.3.5 | Scalarupperlimit3 | read-only | mandatory | High temperature threshold for temperature sensor 3 |
| 1.3.6.1.4.1.20916.1.1.3.6 | Scalarlowerlimit3 | read-only | mandatory | Low temperature threshold for temperature sensor 3 |
| 1.3.6.1.4.1.20916.1.1.3.7 | Scalarupperlimit4 | read-only | mandatory | High temperature threshold for temperature sensor 4 |
| 1.3.6.1.4.1.20916.1.1.3.8 | Scalarlowerlimit4 | read-only | mandatory | Low temperature threshold for temperature sensor 4 |
| 1.3.6.1.4.1.20916.1.1.4 | Nodealarmclear2-t4 | A alarmclear2 trap signifies that the current temperature on sensor 2 has returned to a normal condition and is within the defined high or low threshold. | ||
| 1.3.6.1.4.1.20916.1.1.5 | Nodealarmstart3-t4 | A alarmstart3 trap signifies that the current temperature on sensor 3 is outside the defined high or low threshold. | ||
| 1.3.6.1.4.1.20916.1.1.6 | Nodealarmclear3-t4 | A alarmclear3 trap signifies that the current temperature on sensor 3 has returned to a normal condition and is within the defined high or low threshold. | ||
| 1.3.6.1.4.1.20916.1.1.7 | Nodealarmstart4-t4 | A alarmstart4 trap signifies that the current temperature on sensor 4 is outside the defined high or low threshold. | ||
| 1.3.6.1.4.1.20916.1.1.8 | Nodealarmclear4-t4 | A alarmclear4 trap signifies that the current temperature on sensor 4 has returned to a normal condition and is within the defined high or low threshold. |