MIB Viewer

TEMPAGER3E-MIB

22 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.20916Nodeavtech
1.3.6.1.4.1.20916.1Nodeproducts
1.3.6.1.4.1.20916.1.7NodeTEMPAGER3E
1.3.6.1.4.1.20916.1.7.1Nodesensors
1.3.6.1.4.1.20916.1.7.1.1Nodeinternal
1.3.6.1.4.1.20916.1.7.1.1.1Nodetemperature
1.3.6.1.4.1.20916.1.7.1.1.1.1Scalarinternal-tempcread-onlymandatoryThe internal temperature reading in Celsius. Because the SNMP Protocol does not support floating point numbers, values are scaled by 100 and should be divided …
1.3.6.1.4.1.20916.1.7.1.1.1.2Scalarinternal-tempfread-onlymandatoryThe internal temperature reading in Fahrenheit. Because the SNMP Protocol does not support floating point numbers, values are scaled by 100 and should be divid…
1.3.6.1.4.1.20916.1.7.1.2Nodedigital
1.3.6.1.4.1.20916.1.7.1.2.1Nodedigital-sen1
1.3.6.1.4.1.20916.1.7.1.2.1.1Scalardigital-sen1-1read-onlymandatoryIf this sensor is a Temperature or Temp/Humidity sensor, this value represents the current temperature in Celsius. If this sensor is a Digital Power Sensor, th…
1.3.6.1.4.1.20916.1.7.1.2.1.2Scalardigital-sen1-2read-onlymandatoryIf this sensor is a Temperature or Temp/Humidity sensor, this value represents the current temperature in Fahrenheit. If this sensor is a Digital Power Sensor,…
1.3.6.1.4.1.20916.1.7.1.2.1.3Scalardigital-sen1-3read-onlymandatoryIf this sensor is a Temp/Humidity sensor, this value represents the current relative humidity in % Relative Humidity. If this sensor is a Digital Power Sensor,…
1.3.6.1.4.1.20916.1.7.1.2.1.4Scalardigital-sen1-4read-onlymandatoryIf this sensor is a Temperature or Temp/Humidity sensor, this value represents the current heat index in Fahrenheit. If this sensor is a Digital Power Sensor, …
1.3.6.1.4.1.20916.1.7.1.2.2Nodedigital-sen2
1.3.6.1.4.1.20916.1.7.1.2.2.1Scalardigital-sen2-1read-onlymandatoryIf this sensor is a Temperature or Temp/Humidity sensor, this value represents the current temperature in Celsius. If this sensor is a Digital Power Sensor, th…
1.3.6.1.4.1.20916.1.7.1.2.2.2Scalardigital-sen2-2read-onlymandatoryIf this sensor is a Temperature or Temp/Humidity sensor, this value represents the current temperature in Fahrenheit. If this sensor is a Digital Power Sensor,…
1.3.6.1.4.1.20916.1.7.1.2.2.3Scalardigital-sen2-3read-onlymandatoryIf this sensor is a Temp/Humidity sensor, this value represents the current relative humidity in % Relative Humidity. If this sensor is a Digital Power Sensor,…
1.3.6.1.4.1.20916.1.7.1.2.2.4Scalardigital-sen2-4read-onlymandatoryIf this sensor is a Temperature or Temp/Humidity sensor, this value represents the current heat index in Fahrenheit. If this sensor is a Digital Power Sensor, …
1.3.6.1.4.1.20916.1.7.2Nodetempager3e-snmp-trapA tempager3e-snmp-trap indicates that an alarm condition has occurred on the sensor indicated by the alarmmessage variable.
1.3.6.1.4.1.20916.1.7.2Nodetraps
1.3.6.1.4.1.20916.1.7.2.1Scalaralarmmessageread-onlymandatoryLast Alarm Message