MIB Viewer

TERACOM-TCW121-MIB

99 objects
No module-level DESCRIPTION found.
Imported Objects
RFC-1212OBJECT-TYPE
RFC-1215TRAP-TYPE
RFC1155-SMIenterprises IpAddress
RFC1213-MIBDisplayString
OIDNameAccessStatusDescription
1.3.6.1.4.1.38783Nodeteracom
1.3.6.1.4.1.38783.1Nodeproduct
1.3.6.1.4.1.38783.1.1Scalarnameread-onlymandatoryName of product. e.g. teracom.net etc.
1.3.6.1.4.1.38783.1.2Scalarversionread-onlymandatoryVersion string. e.g. 1.0
1.3.6.1.4.1.38783.1.3Scalardateread-onlymandatoryDate of version
1.3.6.1.4.1.38783.2Nodesetup
1.3.6.1.4.1.38783.2.1Nodenetwork
1.3.6.1.4.1.38783.2.1.1ScalardeviceIPAddressread-writemandatoryDevice IP address
1.3.6.1.4.1.38783.2.1.2ScalarsubnetMaskread-writemandatorySubnet Mask
1.3.6.1.4.1.38783.2.1.3Scalargatewayread-writemandatoryGateway IP address
1.3.6.1.4.1.38783.2.1.4ScalardeviceMACAddressread-writemandatoryDevice MAC address
1.3.6.1.4.1.38783.2.1.5ScalardhcpConfigread-writemandatoryDHCP configuration ON/OFF
1.3.6.1.4.1.38783.2.1.6Scalardnsread-writemandatoryDomain Name Server Address
1.3.6.1.4.1.38783.2.1.7ScalarhostNameread-writemandatoryHost Name
1.3.6.1.4.1.38783.2.2Nodevlan
1.3.6.1.4.1.38783.2.2.1ScalarvlanStatusread-writemandatoryVLAN Status ENABLED/DISABLED
1.3.6.1.4.1.38783.2.2.2ScalarvlanIdread-writemandatoryVLAN ID (0-4095)
1.3.6.1.4.1.38783.2.3NodemacFilter
1.3.6.1.4.1.38783.2.3.1ScalarfilterMACAddress1read-onlymandatoryfilter1 MAC address
1.3.6.1.4.1.38783.2.3.2ScalarfilterMACEnable1read-writemandatoryMAC filter 1 Enable ENABLED/DISABLED
1.3.6.1.4.1.38783.2.3.3ScalarfilterMACAddress2read-writemandatoryfilter2 MAC address
1.3.6.1.4.1.38783.2.3.4ScalarfilterMACEnable2read-writemandatoryMAC filter 2 Enable ENABLED/DISABLED
1.3.6.1.4.1.38783.2.3.5ScalarfilterMACAddress3read-writemandatoryfilter3 MAC address
1.3.6.1.4.1.38783.2.3.6ScalarfilterMACEnable3read-writemandatoryMAC filter 3 Enable ENABLED/DISABLED
1.3.6.1.4.1.38783.2.4NodesnmpSetup
1.3.6.1.4.1.38783.2.4.1ScalarsnmpConfigurationread-writemandatorySNMP Configuration ENABLED/DISABLED
1.3.6.1.4.1.38783.2.4.2ScalartrapEnabledread-writemandatoryIndicates if this trap entry is enabled or not.
1.3.6.1.4.1.38783.2.4.3ScalartrapReceiverIPAddressread-writemandatoryTrap receiver IP address
1.3.6.1.4.1.38783.2.4.4ScalartrapCommunityread-writemandatoryTrap community to be used by agent to send trap
1.3.6.1.4.1.38783.2.4.5ScalartrapIntervalread-writemandatoryTrap Interval
1.3.6.1.4.1.38783.2.4.6ScalarmaxNumberOfTrapsread-writemandatoryMax Number of Traps
1.3.6.1.4.1.38783.2.5Nodesensor1
1.3.6.1.4.1.38783.2.5.1Nodetemperature1
1.3.6.1.4.1.38783.2.5.1.1Scalartemperature1Minread-writemandatoryTemperature minimum
1.3.6.1.4.1.38783.2.5.1.2Scalartemperature1Maxread-writemandatoryTemperature maximum
1.3.6.1.4.1.38783.2.5.1.3Scalartemperature1Hystread-writemandatoryTemperature hysteresis
1.3.6.1.4.1.38783.2.5.1.4Scalartemperature1Actionread-writemandatoryTemperature Action
1.3.6.1.4.1.38783.2.5.2Nodehumidity1
1.3.6.1.4.1.38783.2.5.2.1Scalarhumidity1Minread-writemandatoryHumidity minimum
1.3.6.1.4.1.38783.2.5.2.2Scalarhumidity1Maxread-writemandatoryHumidity maximum
1.3.6.1.4.1.38783.2.5.2.3Scalarhumidity1Hystread-writemandatoryHumidity hysteresis
1.3.6.1.4.1.38783.2.5.2.4Scalarhumidity1Actionread-writemandatoryHumidity Action
1.3.6.1.4.1.38783.2.6Nodesensor2
1.3.6.1.4.1.38783.2.6.1Nodetemperature2
1.3.6.1.4.1.38783.2.6.1.1Scalartemperature2Minread-writemandatoryTemperature minimum
1.3.6.1.4.1.38783.2.6.1.2Scalartemperature2Maxread-writemandatoryTemperature maximum
1.3.6.1.4.1.38783.2.6.1.3Scalartemperature2Hystread-writemandatoryTemperature hysteresis
1.3.6.1.4.1.38783.2.6.1.4Scalartemperature2Actionread-writemandatoryTemperature Action
1.3.6.1.4.1.38783.2.6.2Nodehumidity2
1.3.6.1.4.1.38783.2.6.2.1Scalarhumidity2Minread-writemandatoryHumidity minimum
1.3.6.1.4.1.38783.2.6.2.2Scalarhumidity2Maxread-writemandatoryHumidity maximum
1.3.6.1.4.1.38783.2.6.2.3Scalarhumidity2Hystread-writemandatoryHumidity hysteresis
1.3.6.1.4.1.38783.2.6.2.4Scalarhumidity2Actionread-writemandatoryHumidity Action
1.3.6.1.4.1.38783.2.7NodeanalogInput
1.3.6.1.4.1.38783.2.7.1Nodeinput1
1.3.6.1.4.1.38783.2.7.1.1Scalarvoltage1Minread-writemandatoryVoltage minimum
1.3.6.1.4.1.38783.2.7.1.2Scalarvoltage1Maxread-writemandatoryVoltage maximum
1.3.6.1.4.1.38783.2.7.1.3Scalarvoltage1Hystread-writemandatoryVoltage hysteresis
1.3.6.1.4.1.38783.2.7.1.4Scalarvoltage1Actionread-writemandatoryVoltage Action
1.3.6.1.4.1.38783.2.7.1.5Scalarvoltage1Rangeread-writemandatoryVoltage Range
1.3.6.1.4.1.38783.2.7.2Nodeinput2
1.3.6.1.4.1.38783.2.7.2.1Scalarvoltage2Minread-writemandatoryVoltage minimum
1.3.6.1.4.1.38783.2.7.2.2Scalarvoltage2Maxread-writemandatoryVoltage maximum
1.3.6.1.4.1.38783.2.7.2.3Scalarvoltage2Hystread-writemandatoryVoltage hysteresis
1.3.6.1.4.1.38783.2.7.2.4Scalarvoltage2Actionread-writemandatoryVoltage Action
1.3.6.1.4.1.38783.2.7.2.5Scalarvoltage2Rangeread-writemandatoryVoltage Range
1.3.6.1.4.1.38783.2.8NodedigitalInput
1.3.6.1.4.1.38783.2.8.1ScalardigitalInput1Actionread-writemandatoryDigital Input1 Action
1.3.6.1.4.1.38783.2.8.2ScalardigitalInput2Actionread-writemandatoryDigital Input1 Action
1.3.6.1.4.1.38783.2.9Noderelay
1.3.6.1.4.1.38783.2.9.1Scalarrelay1ControledByread-writemandatoryRelay1 Control Item
1.3.6.1.4.1.38783.2.9.2Scalarrelay2ControledByread-writemandatoryRelay2 Control Item
1.3.6.1.4.1.38783.2.9.3ScalarrelayPulseWidthread-writemandatoryRelay Pulse Width
1.3.6.1.4.1.38783.2.10Noderecipients
1.3.6.1.4.1.38783.2.10.1Scalarrecipient1EmailAddressread-writemandatoryRecipient1's e-mail address
1.3.6.1.4.1.38783.3NodemonitorNcontrol
1.3.6.1.4.1.38783.3.1ScalardigitalInput1Stateread-onlymandatoryDigital1 Input State
1.3.6.1.4.1.38783.3.2ScalardigitalInput2Stateread-onlymandatoryDigital2 Input State
1.3.6.1.4.1.38783.3.3Scalarrelay1Stateread-writemandatoryRelay1 State
1.3.6.1.4.1.38783.3.4Scalarrelay1Pulseread-writemandatoryRelay1 Pulse
1.3.6.1.4.1.38783.3.5Scalarrelay2Stateread-writemandatoryRelay2 State
1.3.6.1.4.1.38783.3.6Scalarrelay2Pulseread-writemandatoryRelay2 Pulse
1.3.6.1.4.1.38783.3.7Scalarvoltage1x10Intread-onlymandatoryVoltage1 x10 in Integer format
1.3.6.1.4.1.38783.3.8Scalarvoltage2x10Intread-onlymandatoryVoltage2 x10 in Integer format
1.3.6.1.4.1.38783.3.9Scalartemp1x10Intread-onlymandatoryTemperature1 x10 in Integer format
1.3.6.1.4.1.38783.3.10Scalartemp2x10Intread-onlymandatoryTemperature2 x10 in Integer format
1.3.6.1.4.1.38783.3.11Scalarhumi1x10Intread-onlymandatoryHumidity1 x10 in Integer format
1.3.6.1.4.1.38783.3.12Scalarhumi2x10Intread-onlymandatoryHumidity2 x10 in Integer format
1.3.6.1.4.1.38783.3.13ScalarconfigurationSavedread-writemandatoryConfiguration save status SAVED/UNSAVED
1.3.6.1.4.1.38783.3.14ScalarrestartDeviceread-writemandatoryRestart Device
1.3.6.1.4.1.38783.101NodetrcDigitalInput1StateThis trap is sent each time when Digital Input 1 changes its state
1.3.6.1.4.1.38783.102NodetrcDigitalInput2StateThis trap is sent each time when Digital Input 1 changes its state
1.3.6.1.4.1.38783.103NodetrcVoltage1x10IntThe voltage measured on Analog Input 1 entered alarm condition
1.3.6.1.4.1.38783.104NodetrcVoltage2x10IntThe voltage measured on Analog Input 2 entered alarm condition
1.3.6.1.4.1.38783.105NodetrcTemp1x10IntTemperature 1 entered alarm condition
1.3.6.1.4.1.38783.106NodetrcTemp2x10IntTemperature 2 entered alarm condition
1.3.6.1.4.1.38783.107NodetrcHumi1x10IntHumidity 1 entered alarm condition
1.3.6.1.4.1.38783.108NodetrcHumi2x10IntHumidity 2 entered alarm condition
1.3.6.1.4.1.38783.109NodetrcRestartDeviceDevice restart