TN-LOOP-PROTECT-MIB
19 objects
The mib module for managing all transition products with Loop protection
Imported Objects
| ENTITY-MIB | entPhysicalIndex |
| IF-MIB | ifIndex |
| SNMPv2-CONF | MODULE-COMPLIANCE OBJECT-GROUP |
| SNMPv2-SMI | MODULE-IDENTITY OBJECT-TYPE |
| SNMPv2-TC | DateAndTime DisplayString TimeStamp TruthValue |
| TRANSITION-SMI | tnProducts |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.868.2.5.22 | IdentitytnLoopProtectMIB | The mib module for managing all transition products with Loop protection | ||
| 1.3.6.1.4.1.868.2.5.22.0 | NodetnLoopProtectNotifications | |||
| 1.3.6.1.4.1.868.2.5.22.0.1 | NotificationtnLoopProtectLoopDetectedNotification | current | A tnLoopProtectLoopDetectedNotification signifies that a loop has been detected by the loop protection protocol. Additional infomation contains port number ,co… | |
| 1.3.6.1.4.1.868.2.5.22.1 | NodetnLoopProtectObjects | |||
| 1.3.6.1.4.1.868.2.5.22.1.1 | NodetnLoopProtectMgmt | |||
| 1.3.6.1.4.1.868.2.5.22.1.1.1 | TabletnLoopProtectBaseTable | not-accessible | current | This table is used for configuring global loop protect variables |
| 1.3.6.1.4.1.868.2.5.22.1.1.1.1 | RowtnLoopProtectBaseEntry | not-accessible | current | This entry contains configuration elements of tnLoopProtectBaseTable |
| 1.3.6.1.4.1.868.2.5.22.1.1.1.1.1 | ColumntnLoopProtectEnable | read-write | current | Indicates whether the loop protect is enable on this device. |
| 1.3.6.1.4.1.868.2.5.22.1.1.1.1.2 | ColumntnLoopProtectTxTime | read-write | current | The interval in seconds between each loop protection PDU sent on each port. valid values are 1 to 10 seconds,the default value is 5 seconds. |
| 1.3.6.1.4.1.868.2.5.22.1.1.1.1.3 | ColumntnLoopProtectShutdownTime | read-write | current | The period (in seconds) for which a port will be kept disabled in the event of a loop is detected (and the port action shuts down the port). Valid values are 0… |
| 1.3.6.1.4.1.868.2.5.22.1.1.2 | TabletnLoopProtectPortTable | not-accessible | current | This table is used for configuring loop protect options for each port |
| 1.3.6.1.4.1.868.2.5.22.1.1.2.1 | RowtnLoopProtectPortEntry | not-accessible | current | This entry contains configuration element of tnLoopProtectBaseTable |
| 1.3.6.1.4.1.868.2.5.22.1.1.2.1.1 | ColumntnLoopProtectPortEnable | read-write | current | Controls whether loop protection is enabled on this switch port. |
| 1.3.6.1.4.1.868.2.5.22.1.1.2.1.2 | ColumntnLoopProtectPortAction | read-write | current | Configures the action performed when a loop is detected on a port. Valid values are Shutdown Port(1), Shutdown Port and Log(2) or Log Only(3). |
| 1.3.6.1.4.1.868.2.5.22.1.1.2.1.3 | ColumntnLoopProtectPortTxModeEnable | read-write | current | Controls whether the port is actively generating loop protection PDU's, or whether it is just passively looking for looped PDU's. |
| 1.3.6.1.4.1.868.2.5.22.1.1.2.1.4 | ColumntnLoopProtectPortLoopCount | read-only | current | The number of loops detected on this port. |
| 1.3.6.1.4.1.868.2.5.22.1.1.2.1.5 | ColumntnLoopProtectPortStatus | read-only | current | The status of the port. up(1): the status of the port is up. down(2):the status of the port is down. disable(3):loop is detected in this port and shutdown is t… |
| 1.3.6.1.4.1.868.2.5.22.1.1.2.1.6 | ColumntnLoopProtectPortLoopDetected | read-only | current | Indicates Whether a loop is currently detected on the port. |
| 1.3.6.1.4.1.868.2.5.22.1.1.2.1.7 | ColumntnLoopProtectPortLastLoopTime | read-only | current | The time of the last loop event detected. |