MIB Viewer

TN-LOOP-PROTECT-MIB

19 objects
The mib module for managing all transition products with Loop protection
OIDNameAccessStatusDescription
1.3.6.1.4.1.868.2.5.22IdentitytnLoopProtectMIBThe mib module for managing all transition products with Loop protection
1.3.6.1.4.1.868.2.5.22.0NodetnLoopProtectNotifications
1.3.6.1.4.1.868.2.5.22.0.1NotificationtnLoopProtectLoopDetectedNotificationcurrentA tnLoopProtectLoopDetectedNotification signifies that a loop has been detected by the loop protection protocol. Additional infomation contains port number ,co…
1.3.6.1.4.1.868.2.5.22.1NodetnLoopProtectObjects
1.3.6.1.4.1.868.2.5.22.1.1NodetnLoopProtectMgmt
1.3.6.1.4.1.868.2.5.22.1.1.1TabletnLoopProtectBaseTablenot-accessiblecurrentThis table is used for configuring global loop protect variables
1.3.6.1.4.1.868.2.5.22.1.1.1.1RowtnLoopProtectBaseEntrynot-accessiblecurrentThis entry contains configuration elements of tnLoopProtectBaseTable
1.3.6.1.4.1.868.2.5.22.1.1.1.1.1ColumntnLoopProtectEnableread-writecurrentIndicates whether the loop protect is enable on this device.
1.3.6.1.4.1.868.2.5.22.1.1.1.1.2ColumntnLoopProtectTxTimeread-writecurrentThe interval in seconds between each loop protection PDU sent on each port. valid values are 1 to 10 seconds,the default value is 5 seconds.
1.3.6.1.4.1.868.2.5.22.1.1.1.1.3ColumntnLoopProtectShutdownTimeread-writecurrentThe period (in seconds) for which a port will be kept disabled in the event of a loop is detected (and the port action shuts down the port). Valid values are 0…
1.3.6.1.4.1.868.2.5.22.1.1.2TabletnLoopProtectPortTablenot-accessiblecurrentThis table is used for configuring loop protect options for each port
1.3.6.1.4.1.868.2.5.22.1.1.2.1RowtnLoopProtectPortEntrynot-accessiblecurrentThis entry contains configuration element of tnLoopProtectBaseTable
1.3.6.1.4.1.868.2.5.22.1.1.2.1.1ColumntnLoopProtectPortEnableread-writecurrentControls whether loop protection is enabled on this switch port.
1.3.6.1.4.1.868.2.5.22.1.1.2.1.2ColumntnLoopProtectPortActionread-writecurrentConfigures the action performed when a loop is detected on a port. Valid values are Shutdown Port(1), Shutdown Port and Log(2) or Log Only(3).
1.3.6.1.4.1.868.2.5.22.1.1.2.1.3ColumntnLoopProtectPortTxModeEnableread-writecurrentControls whether the port is actively generating loop protection PDU's, or whether it is just passively looking for looped PDU's.
1.3.6.1.4.1.868.2.5.22.1.1.2.1.4ColumntnLoopProtectPortLoopCountread-onlycurrentThe number of loops detected on this port.
1.3.6.1.4.1.868.2.5.22.1.1.2.1.5ColumntnLoopProtectPortStatusread-onlycurrentThe status of the port. up(1): the status of the port is up. down(2):the status of the port is down. disable(3):loop is detected in this port and shutdown is t…
1.3.6.1.4.1.868.2.5.22.1.1.2.1.6ColumntnLoopProtectPortLoopDetectedread-onlycurrentIndicates Whether a loop is currently detected on the port.
1.3.6.1.4.1.868.2.5.22.1.1.2.1.7ColumntnLoopProtectPortLastLoopTimeread-onlycurrentThe time of the last loop event detected.