MIB Viewer

TRAPS-COMMON

20 objects
Versa Networks' Enterprise MIB for common TRAP objects
OIDNameAccessStatusDescription
1.3.6.1.4.1.42359.2.2.2.3IdentityversaTrapsCommonVersa Networks' Enterprise MIB for common TRAP objects
1.3.6.1.4.1.42359.2.2.2.3.1NodetrapObjects
1.3.6.1.4.1.42359.2.2.2.3.1.1ScalaralarmIndexnot-accessiblecurrentA unique value, greater than zero, for each alarm. The value for each alarm must remain constant at least from one re-initialization of the entity to the next …
1.3.6.1.4.1.42359.2.2.2.3.1.2ScalaralarmTypeaccessible-for-notifycurrentThis provides an identification of the alarm type. Together with tfAlarmSpecificProblem, this is a unique identification of the alarm. Different managed object…
1.3.6.1.4.1.42359.2.2.2.3.1.3ScalaralarmDeviceaccessible-for-notifycurrentThe name of the managed device. May also be the system itself for self-management alarms. Note that this object is not fine-grained enough to pinpoint the alar…
1.3.6.1.4.1.42359.2.2.2.3.1.4ScalaralarmObjectaccessible-for-notifycurrentName of alarm object within a device based on YANG naming. Note that the granularity must be good enough to guarantee unique alarm states and relevant resource…
1.3.6.1.4.1.42359.2.2.2.3.1.5ScalaralarmObjectOIDaccessible-for-notifycurrentName of alarm object based on SNMP naming. Note that the granularity must be good enough to guarantee unique alarm states and relevant resource identification …
1.3.6.1.4.1.42359.2.2.2.3.1.6ScalaralarmSpecificProblemaccessible-for-notifycurrentThis object is used when the 'tfAlarmType' object cannot uniquely identify the alarm type. Normally, this is not the case, and this leaf is the empty string.
1.3.6.1.4.1.42359.2.2.2.3.1.7ScalaralarmClassaccessible-for-notifycurrentThe severity of the alarm as defined by X.733. Note that this may not be the original severity since the alarm may have changed severity. For cleared alarms, t…
1.3.6.1.4.1.42359.2.2.2.3.1.8ScalaralarmEventTypeaccessible-for-notifycurrentThe event type as defined in X.733/X.736.
1.3.6.1.4.1.42359.2.2.2.3.1.9ScalaralarmProbableCauseaccessible-for-notifycurrentThe probable cause as defined in X.733/X.736.
1.3.6.1.4.1.42359.2.2.2.3.1.10ScalaralarmOrigTimeaccessible-for-notifycurrentTime for alarm raise
1.3.6.1.4.1.42359.2.2.2.3.1.11ScalaralarmTimeaccessible-for-notifycurrentA time stamp of the alarm state change event. Note that this variable represents the last change of the alarm state, like changed severity or additional text. …
1.3.6.1.4.1.42359.2.2.2.3.1.12ScalaralarmSeverityaccessible-for-notifycurrentThe severity of the alarm as defined by X.733. Note that this may not be the original severity since the alarm may have changed severity. For cleared alarms, t…
1.3.6.1.4.1.42359.2.2.2.3.1.13ScalaralarmHasClearaccessible-for-notifycurrentIndicates if the alarm is cleared or not.
1.3.6.1.4.1.42359.2.2.2.3.1.14ScalaralarmTextaccessible-for-notifycurrentA user friendly text describing the alarm. Intended for human consumption.
1.3.6.1.4.1.42359.2.2.2.3.1.15ScalartenantNameaccessible-for-notifycurrentTenant name
1.3.6.1.4.1.42359.2.2.2.3.1.16ScalarthresholdStatusaccessible-for-notifycurrentStatus set/clear
1.3.6.1.4.1.42359.2.2.2.3.1.17ScalarcurrentUtilizationaccessible-for-notifycurrentCurrent utilization in percentage
1.3.6.1.4.1.42359.2.2.2.3.1.18ScalaralarmKeyaccessible-for-notifycurrentThis object can be used as a key to uniquely identify an alarm