MIB Viewer

TROPIC-SYNCE-MIB

95 objects
Synchronous Ethernet MIB attributes.
OIDNameAccessStatusDescription
1.3.6.1.4.1.7483.1.1.2.2.4.6IdentitytnSyncEMibModuleofSynchronous Ethernet MIB attributes.
1.3.6.1.4.1.7483.2.2.4.8.1NodetnSyncEConf
1.3.6.1.4.1.7483.2.2.4.8.1.1NodetnSyncEGroups
1.3.6.1.4.1.7483.2.2.4.8.1.1.1GrouptnSyncEGroupcurrent.
1.3.6.1.4.1.7483.2.2.4.8.1.1.2GrouptnSyncELineRefGroupcurrent.
1.3.6.1.4.1.7483.2.2.4.8.1.1.3GrouptnSyncEControlGroupcurrent.
1.3.6.1.4.1.7483.2.2.4.8.1.1.4GrouptnSyncEPortGroupcurrent.
1.3.6.1.4.1.7483.2.2.4.8.1.1.5GrouptnSyncEStationClockGroupcurrent.
1.3.6.1.4.1.7483.2.2.4.8.1.1.6GrouptnSyncEBITSPortGroupcurrent.
1.3.6.1.4.1.7483.2.2.4.8.1.1.7GrouptnWanGroupcurrent.
1.3.6.1.4.1.7483.2.2.4.8.1.1.8GrouptnSyncEPacketswitchControlGroupcurrent.
1.3.6.1.4.1.7483.2.2.4.8.1.2NodetnSyncECompliances
1.3.6.1.4.1.7483.2.2.4.8.1.2.1CompliancetnSyncECompliancecurrent.
1.3.6.1.4.1.7483.2.2.4.8.2NodetnSyncEObjs
1.3.6.1.4.1.7483.2.2.4.8.2.1NodetnSyncEBasics
1.3.6.1.4.1.7483.2.2.4.8.2.1.1TabletnSyncETablenot-accessiblecurrentTable of Sync-E attributes.
1.3.6.1.4.1.7483.2.2.4.8.2.1.1.1RowtnSyncEEntrynot-accessiblecurrent.
1.3.6.1.4.1.7483.2.2.4.8.2.1.1.1.1ColumntnSyncESyncMsgread-createcurrentDetermines if the timing reference selection for system timing uses Synchronization Status Message (SSM) Quality Levels or Enhanced Quality Levels.
1.3.6.1.4.1.7483.2.2.4.8.2.1.1.1.2ColumntnSyncEActiveRefread-onlycurrentThe ID of the association line reference.
1.3.6.1.4.1.7483.2.2.4.8.2.1.1.1.3ColumntnSyncEWTRread-createcurrentThe system timing WTR. Current configurable range: 0 to 12, and 999999.
1.3.6.1.4.1.7483.2.2.4.8.2.1.1.1.4ColumntnSyncESwCmdLineRefread-createcurrentThe third byte represents the switch command: 1 - nocmd 2 - clear 3 - lockout 4 - forceswitch 5 - mannual 6 - auto 7 - clearlockout. The last byte represents t…
1.3.6.1.4.1.7483.2.2.4.8.2.1.1.1.5ColumntnSyncEClkModStateread-onlycurrentThe Sync-E clock mode state.
1.3.6.1.4.1.7483.2.2.4.8.2.1.1.1.6ColumntnSyncESystemQLread-onlycurrentThe value of the system quality level (SSM), shown in following: 31 - not applicable When the NE is in SDH mode: 0 - quality unknown 1 - PRC 2 - SSU_A 3 - SSU_…
1.3.6.1.4.1.7483.2.2.4.8.2.1.1.1.7ColumntnSyncEQLDegradeThresholdread-createcurrentThe threshold value of SSM quality level degradation for systme timing reference. When the NE is in SDH mode: 1 - PRC 2 - SSU_A 3 - SSU_B 4 - SEC - Default 23 …
1.3.6.1.4.1.7483.2.2.4.8.2.1.1.1.8ColumntnSyncECurrentActiveLineRefFreqOffread-onlycurrentThe current frequency offset of the active timing reference.
1.3.6.1.4.1.7483.2.2.4.8.2.1.1.1.9ColumntnSyncEAlmProfNameread-createcurrent.
1.3.6.1.4.1.7483.2.2.4.8.2.1.2TabletnSyncELineRefTablenot-accessiblecurrentTable of VTS map.
1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1RowtnSyncELineRefEntrynot-accessiblecurrent.
1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.1ColumntnSyncELineRefIndexnot-accessiblecurrentThe ifIndex of the line reference table.
1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.2ColumntnSyncELineRefAssignedPortread-createcurrentThe assigned port for the line reference.
1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.3ColumntnSyncELineRefPriorityread-createcurrentLine reference priority. Current configurable range: 0 to 8.
1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.4ColumntnSyncELineRefAdminStateread-createcurrentThe administrative state of the line reference.
1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.5ColumntnSyncELineRefOperStateread-onlycurrentThe operating state of the line reference.
1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.6ColumntnSyncELineLockOutread-onlycurrentIf lock out line reference or not.
1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.7ColumntnSyncELineRefStateread-onlycurrentThe Sync-E line reference state.
1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.8ColumntnSyncELineRefSwStateread-onlycurrentThe Sync-E line reference switch state.
1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.9ColumntnSyncELineRefIncSSMMsgread-onlycurrentThis object indicates the current value of incoming QL on that port. 30 - unstable 31 - not applicable When the NE works in SDH mode: 0 - Unknown 1 - PRC 2 - S…
1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.10ColumntnSyncELineRefIncSSMStatusread-onlycurrentThis object indicates the current status of incoming QL on that port. 0: Valid 1: Invalid 2: Not Supported 3: Not Applicable It's applicable only to the timing…
1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.11ColumntnSyncELineRefIncSSMSuppread-createcurrentEnable or disable the line reference incoming QL processing.
1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.12ColumntnSyncELineRefProvQLread-createcurrentManually provisioned incoming SSM value for the line reference. The value can be: 0 - AUTO When the NE is in SDH mode: 1 - PRC 2 - SSU_A 3 - SSU_B 4 - SEC 5 - …
1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.13ColumntnSyncELineRefAssociatedPortread-createcurrentThe associated physical port of the line reference. This parameter replaces tnSyncELineRefAssignedPort in order to support assigning a line reference to a port…
1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.14ColumntnSyncELineRefPriorityOfStationClockread-createcurrentLine reference priority for the output station clock. Current configurable range: 0 to 8.
1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.15ColumntnSyncELineRefLockOutOfStationClockread-onlycurrentIf lock out the line reference or not for the output station clock.
1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.16ColumntnSyncELineRefSwStateOfStationClockread-onlycurrentThe Sync-E line reference switch state of the output station clock.
1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.17ColumntnSyncELineRefCurrentFreqOffread-onlycurrentThe current frequency offset of the timing reference.
1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.18ColumntnSyncELineRefAlmProfNameread-createcurrent.
1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.19ColumntnSyncELineRefIncExtdQLTLVClockIDread-onlycurrentIncoming Extended QL TLV Clock ID.
1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.20ColumntnSyncELineRefIncExtdQLTLVMixedClockTyperead-onlycurrentIncoming Extended QL TLV Mixed Clock Type Flag.
1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.21ColumntnSyncELineRefIncExtdQLTLVPartialChainread-onlycurrentIncoming Extended QL TLV Partial Chain Flag.
1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.22ColumntnSyncELineRefIncExtdQLTLVNumeEECread-onlycurrentIncoming Extended QL TLV Number of eEEC.
1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.23ColumntnSyncELineRefIncExtdQLTLVNumEECread-onlycurrentIncoming Extended QL TLV Number of EEC.
1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.24ColumntnSyncELineRefProvQLOfStationClockread-createcurrentManually provisioned incoming SSM value of the line reference output timing. The value can be: 0 - AUTO When the NE is in SDH mode: 1 - PRC 2 - SSU_A 3 - SSU_B…
1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.25ColumntnSyncELineRefIncSSMMsgOfStationClockread-onlycurrentThis object indicates the current value of incoming QL for output timing on that port. 30 - unstable 31 - not applicable When the NE works in SDH mode: 0 - Unk…
1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.26ColumntnSyncELineRefIncSSMStatusOfStationClockread-onlycurrentThis object indicates the current status of incoming QL on that port for output timing. 0: Valid 1: Invalid 2: Not Supported 3: Not Applicable It's applicable …
1.3.6.1.4.1.7483.2.2.4.8.2.1.3TabletnSyncEControlTablenot-accessiblecurrentTable of Sync-E Control attributes.
1.3.6.1.4.1.7483.2.2.4.8.2.1.3.1RowtnSyncEControlEntrynot-accessiblecurrent.
1.3.6.1.4.1.7483.2.2.4.8.2.1.3.1.1ColumntnSyncEControlEECEnableread-createcurrentenable - The Synchronous Ethernet is supported for the pack and the synchronization attributes can be configured. disable - The Synchronous Ethernet is not sup…
1.3.6.1.4.1.7483.2.2.4.8.2.1.4TabletnSyncEPortTablenot-accessiblecurrentTable of Sync-E Port attributes.
1.3.6.1.4.1.7483.2.2.4.8.2.1.4.1RowtnSyncEPortEntrynot-accessiblecurrent.
1.3.6.1.4.1.7483.2.2.4.8.2.1.4.1.1ColumntnSyncEOprModeread-createcurrentThe port Synchronous Ethernet Operation Mode. When the port is in SYNC mode, recovered clock of its input signal can be selected as a reference clock to the sy…
1.3.6.1.4.1.7483.2.2.4.8.2.1.4.1.2ColumntnSyncEOutgoingForceSsmTransread-createcurrentThe port SSM/Quality Level Transmission value. The value can be: In SDH mode - act, prc, ssua, ssub, sec, dnu, ePRTC, PRTC, ePRC, eSEC, none; In sonet mode - a…
1.3.6.1.4.1.7483.2.2.4.8.2.1.5TabletnSyncEStationClockTablenot-accessiblecurrentTable of Sync-E station clock attributes.
1.3.6.1.4.1.7483.2.2.4.8.2.1.5.1RowtnSyncEStationClockEntrynot-accessiblecurrent.
1.3.6.1.4.1.7483.2.2.4.8.2.1.5.1.1ColumntnSyncEStationClockSyncMsgread-createcurrentDetermines if the timing reference selection for station clock timing uses Synchronization Status Message (SSM) Quality Levels or Enhanced Quality Levels.
1.3.6.1.4.1.7483.2.2.4.8.2.1.5.1.2ColumntnSyncEStationClockActiveRefread-onlycurrentThe ID of the association line reference.
1.3.6.1.4.1.7483.2.2.4.8.2.1.5.1.3ColumntnSyncEStationClockWTRread-createcurrentThe station clock timing WTR. Current configurable range: 0 to 12, and 999999.
1.3.6.1.4.1.7483.2.2.4.8.2.1.5.1.4ColumntnSyncEStationClockSwCmdLineRefread-createcurrentThe third byte represents the switch command: 1 - nocmd 2 - clear 3 - lockout 4 - forceswitch 5 - mannual 6 - auto 7 - clearlockout. The last byte represents t…
1.3.6.1.4.1.7483.2.2.4.8.2.1.5.1.5ColumntnSyncEStationClockSystemQLread-onlycurrentThe value of the system quality level (SSM) for the output timing clock, shown in following: 31 - not applicable When the NE is in SDH mode: 0 - quality unknow…
1.3.6.1.4.1.7483.2.2.4.8.2.1.5.1.6ColumntnSyncEStationClockQLThresholdread-createcurrentSpecifies the threshold value for the quality level i.e., SSM value for squelching the output towards timing output. If the quality value of the current select…
1.3.6.1.4.1.7483.2.2.4.8.2.1.5.1.7ColumntnSyncEStationClockOutSelread-createcurrentSpecifies which signal is selected for the output station clock: OUTTIM - Output is selected from output timing selection process SETG - Output is selected fro…
1.3.6.1.4.1.7483.2.2.4.8.2.1.5.1.8ColumntnSyncEStationClockAlmProfNameread-createcurrent.
1.3.6.1.4.1.7483.2.2.4.8.2.1.6TabletnSyncEBITSPortTablenot-accessiblecurrentTable of BITS port attributes.
1.3.6.1.4.1.7483.2.2.4.8.2.1.6.1RowtnSyncEBITSPortEntrynot-accessiblecurrent.
1.3.6.1.4.1.7483.2.2.4.8.2.1.6.1.1ColumntnSyncEBITSPortDirectionread-createcurrentIndicate the direction of the BITS port.
1.3.6.1.4.1.7483.2.2.4.8.2.1.6.1.2ColumntnSyncEBITSPortSignalTyperead-createcurrentSpecify the signal type for the BITS interface: 0 - 2MHz 1 - unframed E1 2 - framed E1 without SSM 3 - framed E1 with SSM 4 - DS1 SF 5 - DS1 ESF. In SDH mode, …
1.3.6.1.4.1.7483.2.2.4.8.2.1.6.1.3ColumntnSyncEBITSPortSaBitread-createcurrentSpecifies the Sa bit location used to carry the SSM information. This parameter is only applicable when tnSyncEBITSPortSignalType = 3 (framed E1 with SSM)
1.3.6.1.4.1.7483.2.2.4.8.2.1.6.1.4ColumntnSyncEBITSPortOutputSSMTransread-createcurrentThe port SSM/Quality Level Transmission value. The value can be: In SDH mode - act, prc, ssua, ssub, sec, dnu, none; In sonet mode - act, stu, prs, st2, sts3e,…
1.3.6.1.4.1.7483.2.2.4.8.2.1.6.1.5ColumntnSyncEBITSPortOutputAISModeread-createcurrentSpecifies which signal is inserted for the timing output port if the output signal is squelched. The parameter is only applicable for output port types support…
1.3.6.1.4.1.7483.2.2.4.8.2.1.6.1.6ColumntnSyncEBITSPortLineImpedanceread-createcurrentNominal line impedance. When in SDH mode, imp75ohms or imp120ohms could be used and the default is imp120ohms. When in ONET mode, imp100ohms could be used and …
1.3.6.1.4.1.7483.2.2.4.8.2.1.6.1.7ColumntnSyncEBITSPortLineCoderead-createcurrentLine code. This attribute is applicable when tnSyncEBITSPortSignalType is DS1 SF or DS1 ESF.
1.3.6.1.4.1.7483.2.2.4.8.2.1.6.1.8ColumntnSyncEBITSPortLboread-createcurrentLine equalization value for the BITS output port, taking one of the following values: - lbo: no compensation - lbo1: 0 to 133 feet - lbo2: 133 to 266 feet - lb…
1.3.6.1.4.1.7483.2.2.4.8.2.1.6.1.9ColumntnSyncEBITSPortAlmProfNameread-createcurrentAlarm profile for BITs port
1.3.6.1.4.1.7483.2.2.4.8.2.1.7TabletnWanTablenot-accessiblecurrentTable of Wan attributes.
1.3.6.1.4.1.7483.2.2.4.8.2.1.7.1RowtnWanEntrynot-accessiblecurrent.
1.3.6.1.4.1.7483.2.2.4.8.2.1.7.1.1ColumntnWanAlmProfNameread-createcurrent.
1.3.6.1.4.1.7483.2.2.4.8.2.1.7.1.2ColumntnWanSyncEOprModeread-createcurrentThe Synchronous Ethernet Operation Mode. When in SYNC mode, recovered clock of its input signal can be selected as a reference clock to the system clock.When i…
1.3.6.1.4.1.7483.2.2.4.8.2.1.7.1.3ColumntnWanSyncEOutgoingForceSsmTransread-createcurrentThe port SSM/Quality Level Transmission value. The value can be: In SDH mode - act, prc, ssua, ssub, sec, dnu, ePRTC, PRTC, ePRC, eSEC, none. In SONET mode - a…
1.3.6.1.4.1.7483.2.2.4.8.2.1.7.1.4ColumntnWanAdminStatusread-createcurrentWan administrative state. It may be used to suppress the alarms or disable consequent actions on the WAN entity.
1.3.6.1.4.1.7483.2.2.4.8.2.1.7.1.5ColumntnWanOperStatusread-onlycurrentoperational state of WAN entity
1.3.6.1.4.1.7483.2.2.4.8.2.1.7.1.6ColumntnWanStateQualifierread-onlycurrentIndicates the state qualifier (i.e., the secondary state) of the WAN state.
1.3.6.1.4.1.7483.2.2.4.8.2.1.7.1.7ColumntnWanOperationalCapabilityread-onlycurrentThe partiallyEnabled(3) state means an abnormal state.
1.3.6.1.4.1.7483.2.2.4.8.2.1.7.1.8ColumntnWanDescriptionread-createcurrentWan Description.
1.3.6.1.4.1.7483.2.2.4.8.2.1.8TabletnSyncEPacketswitchControlTablenot-accessiblecurrentTable of Sync-E Control attributes for a packetswitch. This table provides the same functionality as tnSyncEControlTable, but requires a switchid as an index
1.3.6.1.4.1.7483.2.2.4.8.2.1.8.1RowtnSyncEPacketswitchControlEntrynot-accessiblecurrent.
1.3.6.1.4.1.7483.2.2.4.8.2.1.8.1.1ColumntnSyncEPacketswitchControlEECEnableread-createcurrentenable - Synchronous Ethernet is supported for the packetswitch and the synchronization attributes can be configured. disable - Synchronous Ethernet is not sup…