TSL-MIB
47 objects
No module-level DESCRIPTION found.
Imported Objects
| RFC-1212 | OBJECT-TYPE |
| RFC-1215 | TRAP-TYPE |
| RFC1155-SMI | enterprises Opaque |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.6853 | NodetslMIB | |||
| 1.3.6.1.4.1.6853.2 | Nodealarm | |||
| 1.3.6.1.4.1.6853.2.1 | ScalaralarmIdent | read-only | mandatory | Equipment alarms description and version |
| 1.3.6.1.4.1.6853.2.2 | TablealarmTable | not-accessible | mandatory | The table of alarm entries |
| 1.3.6.1.4.1.6853.2.2.1 | RowalarmEntry | not-accessible | mandatory | An alarm entry in the table |
| 1.3.6.1.4.1.6853.2.2.1.1 | ColumnalarmTableIndex | read-only | mandatory | The index into the table |
| 1.3.6.1.4.1.6853.2.2.1.2 | ColumnalarmType | read-only | mandatory | Alarm type |
| 1.3.6.1.4.1.6853.2.2.1.3 | ColumnalarmIndex | read-only | mandatory | Alarm type number |
| 1.3.6.1.4.1.6853.2.2.1.4 | ColumnalarmText | read-write | mandatory | Alarm description |
| 1.3.6.1.4.1.6853.2.2.1.5 | ColumnalarmState | read-only | mandatory | Alarm state |
| 1.3.6.1.4.1.6853.2.2.1.6 | ColumnalarmPolarity | read-write | mandatory | Alarm active polarity (notApplicable for non-gpi alarms) |
| 1.3.6.1.4.1.6853.2.2.1.7 | ColumnalarmData | read-only | optional | Additional alarm data of variable length, according to alarm type. |
| 1.3.6.1.4.1.6853.2.3 | ScalaralarmTotal | read-only | mandatory | The total number of alarms in the table |
| 1.3.6.1.4.1.6853.2.4 | ScalaralarmLocation | read-write | mandatory | The physical location of the equipment generating the alarm |
| 1.3.6.1.4.1.6853.2.5 | ScalaralarmEqptTemp | read-only | optional | Equipment temperature (in degrees Centigrade) |
| 1.3.6.1.4.1.6853.2.6 | ScalaralarmEqptTempHi | read-write | optional | Equipment temperature alarm point (degrees Centigrade) |
| 1.3.6.1.4.1.6853.3 | Nodemdu12 | |||
| 1.3.6.1.4.1.6853.3.1 | Scalarmdu12Ident | read-only | mandatory | Equipment description and version |
| 1.3.6.1.4.1.6853.3.2 | ScalarmduPowerOn | read-write | mandatory | MDU power-on output sequence |
| 1.3.6.1.4.1.6853.3.3 | ScalarmduSeqDelay | read-write | mandatory | Sequential mode delay between outputs |
| 1.3.6.1.4.1.6853.3.4 | TablemduOutputTable | not-accessible | mandatory | Table of output controls |
| 1.3.6.1.4.1.6853.3.4.1 | RowmduOutputEntry | not-accessible | mandatory | An entry in the output table |
| 1.3.6.1.4.1.6853.3.4.1.1 | ColumnmduOutputIndex | read-only | mandatory | Output number |
| 1.3.6.1.4.1.6853.3.4.1.2 | ColumnmduOutputState | read-write | mandatory | MDU Output status |
| 1.3.6.1.4.1.6853.3.4.1.3 | ColumnmduOutputDelay | read-write | mandatory | Output on delay from power on (Delay mode only) |
| 1.3.6.1.4.1.6853.3.4.1.4 | ColumnmduOutputlowerCurrent | read-write | mandatory | Lower current limit for output |
| 1.3.6.1.4.1.6853.3.4.1.5 | ColumnmduOutputupperCurrent | read-write | mandatory | Upper current limit for output |
| 1.3.6.1.4.1.6853.3.4.1.6 | ColumnmduOutputCurrent | read-only | mandatory | Output current |
| 1.3.6.1.4.1.6853.3.4.1.7 | ColumnmduOutputpowerFactor | read-only | mandatory | Output power factor |
| 1.3.6.1.4.1.6853.3.4.1.8 | ColumnmduOutputVA | read-only | mandatory | Output apparent power |
| 1.3.6.1.4.1.6853.3.4.1.9 | ColumnmduOutputWatts | read-only | mandatory | Output real power |
| 1.3.6.1.4.1.6853.3.4.1.10 | ColumnmduOutputCal | read-write | mandatory | Output current measure calibration data |
| 1.3.6.1.4.1.6853.3.5 | ScalarmduPowerStatus | read-only | mandatory | Status of MDU power inlets |
| 1.3.6.1.4.1.6853.3.6 | ScalarmduVoltageCal | read-write | mandatory | Voltage measure calibration data |
| 1.3.6.1.4.1.6853.3.7 | ScalarmduVoltage | read-only | mandatory | Voltage measurement |
| 1.3.6.1.4.1.6853.3.8 | ScalarmduVoltageFloor | read-write | mandatory | Voltage lower limit |
| 1.3.6.1.4.1.6853.3.9 | ScalarmduVoltageLimit | read-write | mandatory | Voltage upper limit |
| 1.3.6.1.4.1.6853.3.10 | ScalarmduTotalCurrent | read-write | mandatory | Total current measurement |
| 1.3.6.1.4.1.6853.3.11 | ScalarmduCurrentLimit | read-write | mandatory | Current total limit |
| 1.3.6.1.4.1.6853.3.12 | ScalarmduAuxRly1 | read-write | mandatory | Auxiliary Relay 1 state |
| 1.3.6.1.4.1.6853.3.13 | ScalarmduAuxRly2 | read-write | mandatory | Auxiliary Relay 2 state |
| 1.3.6.1.4.1.6853.4 | NodealarmTrap | An entry in the alarm table has changed state | ||
| 1.3.6.1.4.1.6853.5 | NodealarmEqptTempHiTrap | The equipment temperature has exceeded the maximum allowed | ||
| 1.3.6.1.4.1.6853.6 | NodealarmEqptTempOkTrap | The equipment temperature is now within limits | ||
| 1.3.6.1.4.1.6853.7 | NodemduPowerStatusTrap | The power input to the MDU has changed state | ||
| 1.3.6.1.4.1.6853.8 | NodemduVoltageStatusTrap | The voltage to the MDU has traversed a limit | ||
| 1.3.6.1.4.1.6853.9 | NodemduTotalCurrentStatusTrap | The total current through the MDU has traversed a limit |