ThreeParMIB
295 objects
This file specifies management information interface for all HPE 3PAR, Primera, Alletra and GreenLake for Block Storage products. This information is normally used by any management software that utilizes SNMP as management standard. The SNMP agent inside the device provides the specified information.
Imported Objects
| SNMPv2-CONF | AGENT-CAPABILITIES MODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP |
| SNMPv2-SMI | Counter64 enterprises Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-IDENTITY OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DisplayString TEXTUAL-CONVENTION |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.12925 | Identitythreepar | This file specifies management information interface for all HPE 3PAR, Primera, Alletra and GreenLake for Block Storage products. This information is normally … | ||
| 1.3.6.1.4.1.12925.1 | Identityinserv | current | InServ product | |
| 1.3.6.1.4.1.12925.1.1 | NodeinservConf | |||
| 1.3.6.1.4.1.12925.1.1.1 | NodeinservGroups | |||
| 1.3.6.1.4.1.12925.1.1.1.1 | NodealertNotifyGroups | |||
| 1.3.6.1.4.1.12925.1.1.1.1.1 | GroupalertNotifyGroup | current | alertTable columns representing details about an event that may affect system operations and performance. | |
| 1.3.6.1.4.1.12925.1.1.1.1.2 | GroupalertNotifyEventsGroup | current | Contains alertNotify events for system alerts. | |
| 1.3.6.1.4.1.12925.1.1.1.2 | NodestoreServAlertsGroups | |||
| 1.3.6.1.4.1.12925.1.1.1.2.1 | GroupstoreServAlertsGroup | current | alertTable columns representing details about an event that may affect system operations and performance. | |
| 1.3.6.1.4.1.12925.1.1.1.2.2 | GroupstoreServAlertsEvents | current | A collection of events for storeServAlerts | |
| 1.3.6.1.4.1.12925.1.1.1.3 | Nodesnmpv2TrapExtensionGroups | |||
| 1.3.6.1.4.1.12925.1.1.1.3.1 | Groupsnmpv2TrapExtensionObjectsGroup | current | The extra object bindings extending selected standard SNMPv2 traps: managerIP extends the authenticationFailure trap. | |
| 1.3.6.1.4.1.12925.1.1.1.3.2 | Groupsnmpv2TrapExtensionEventsGroup | current | SNMPv2 traps extended with extra object bindings by HPE 3PAR. | |
| 1.3.6.1.4.1.12925.1.1.2 | NodeinservCompls | |||
| 1.3.6.1.4.1.12925.1.1.2.1 | NodealertNotifyCompliances | |||
| 1.3.6.1.4.1.12925.1.1.2.1.1 | CompliancealertNotifyCompliance | current | A collection of objects providing basic notifications for a HPE 3PAR server. | |
| 1.3.6.1.4.1.12925.1.1.2.2 | NodestoreServAlertsCompliances | |||
| 1.3.6.1.4.1.12925.1.1.2.2.1 | CompliancestoreServAlertsCompliance | current | A collection of objects providing basic instrumentation for a HPE 3PAR server. | |
| 1.3.6.1.4.1.12925.1.1.2.3 | Nodesnmpv2TrapExtensionCompliances | |||
| 1.3.6.1.4.1.12925.1.1.2.3.1 | Compliancesnmpv2TrapExtensionCompliance | current | Compliance for SNMPv2 standard traps that are extended by HPE 3PAR. | |
| 1.3.6.1.4.1.12925.1.2 | NodeinservEvents | |||
| 1.3.6.1.4.1.12925.1.2.0 | IdentitystoreServAlerts | current | Named alerts with descriptions | |
| 1.3.6.1.4.1.12925.1.2.0.1 | NotificationactiveVlunLimitExceeded | current | There are currently <num_luns> active VLUNs, which is above the supported limit of <max_luns> active VLUNs | |
| 1.3.6.1.4.1.12925.1.2.0.2 | NotificationfcPortError | current | Port <portnum> Failed (Shutdown Due To Too Many Firmware Cores). | |
| 1.3.6.1.4.1.12925.1.2.0.3 | NotificationportDeviceCountExceeded | current | [[sw_port]], supported device count exceeded for port. | |
| 1.3.6.1.4.1.12925.1.2.0.4 | NotificationdiskPortHasExceededIoErrorThreshold | current | Disk [[sw_port]] has exceeded a threshold tracking IO errors. <count> errors have been seen in one hour. | |
| 1.3.6.1.4.1.12925.1.2.0.5 | NotificationcomponentStateChangeTargetModePortWentOffline | current | Target Mode Port Went Offline; Port <node>:<slot>:<port> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.6 | NotificationcomponentStateChangeTooManyInitiators | current | Too many initiators; Port <node>:<slot>:<port> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.7 | NotificationmetadataInconsistencyInAVv | current | [[vvol]] Volume not started due to metadata inconsistency; manual check required. | |
| 1.3.6.1.4.1.12925.1.2.0.8 | NotificationvlmapCountExceedsThreshold | current | VV <vv_name> (<vv_id>) exceeds vlmap count threshold 80% : AR1 <count> AR5 <count> AR5_SEC <count> USR <count> | |
| 1.3.6.1.4.1.12925.1.2.0.9 | NotificationflashcachePerformanceDegradation | current | Flash Cache I/O times are slow on node: <node>. | |
| 1.3.6.1.4.1.12925.1.2.0.10 | NotificationmetadataInconsistencyInADeduplicationGroup | current | <cpg_name> <cpg_id> Deduplication Group not started due to metadata inconsistency; manual check required. | |
| 1.3.6.1.4.1.12925.1.2.0.11 | NotificationvvUnrecoveredDifError | current | Data Integrity Field (DIF) detected inconsistency for [[vvol]] | |
| 1.3.6.1.4.1.12925.1.2.0.12 | NotificationcomponentStateChangeMaintenanceCheckRequired | current | Maintenance Check Required; Virtual Volume <vv_id>(<vv_name>) Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.13 | NotificationcomponentStateChangeLdsNotStarted | current | LDs Not Started; Virtual Volume <vv_id>(<vv_name>) Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.14 | NotificationcomponentStateChangeCopyFailed | current | Copy Failed; Virtual Volume <vv_id>(<vv_name>) Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.15 | NotificationcomponentStateChangeSnapdataInvalid | current | Snapdata Invalid; Virtual Volume <vv_id>(<vv_name>) Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.16 | NotificationcomponentStateChangeInternalConsistencyError | current | Internal Consistency Error; Virtual Volume <vv_id>(<vv_name>) Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.17 | NotificationcomponentStateChangeNeedsToBeChecked | current | Needs To Be Checked; Virtual Volume <vv_id>(<vv_name>) Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.18 | NotificationcomponentStateChangePreserved | current | Preserved; Virtual Volume <vv_id>(<vv_name>) Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.19 | NotificationcomponentStateChangeInvalid | current | Invalid; Virtual Volume <vv_id>(<vv_name>) Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.20 | NotificationcomponentStateChangeStale | current | Stale; Virtual Volume <vv_id>(<vv_name>) Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.21 | NotificationldskHasFailedSet | current | LD <ld_id>(<ld_name>) row <ld_row> set <ld_set> failed. Internal reason <reason>. | |
| 1.3.6.1.4.1.12925.1.2.0.22 | NotificationldAvailabilityHasReduced | current | Some Logical Disks (LDs) in the system are running with reduced availability. | |
| 1.3.6.1.4.1.12925.1.2.0.23 | NotificationlogLdRaidSetFailure | current | Log [[ld]] has a failed raid set: <set_num>. Reason <reason>. | |
| 1.3.6.1.4.1.12925.1.2.0.24 | NotificationdiskMonitorStopped | current | pd wwn <pd_wwn> has failed for too long. Disk monitoring has stopped on this disk. | |
| 1.3.6.1.4.1.12925.1.2.0.25 | NotificationsystemReporterPdPerformanceMajorAlert | current | System Reporter threshold alert <pd_str_data> with condition <pd_valstr1> has been satisfied by pd <pd_valstr0> with value(s) <pd_valstr2>. | |
| 1.3.6.1.4.1.12925.1.2.0.26 | NotificationsystemOvertemp | current | System shutdown for over temp PDs, TOC quorum loss - <num> TOC drives are at or above their spin down temperatures. | |
| 1.3.6.1.4.1.12925.1.2.0.27 | NotificationdiskOvertempButNotSpundown | current | Physical Disk (PD) <pd_id> with World Wide Name (WWN) <pd_wwn> has exceeded its temperature threshold (<disk_temp> C, limit <thres_temp> C) but it could not be… | |
| 1.3.6.1.4.1.12925.1.2.0.28 | NotificationdiskOvertempAndSpundown | current | Physical Disk (PD) <pd_id> with World Wide Name (WWN) <pd_wwn> has exceeded its temperature threshold (<disk_temp> C, limit <thres_temp> C) and it has been spu… | |
| 1.3.6.1.4.1.12925.1.2.0.29 | NotificationdiskOvertempButNotSpundownNoDsk | current | Physical Disk with World Wide Name (WWN) <pd_wwn> has exceeded its temperature threshold (<disk_temp> C, limit <thres_temp> C) but it could not be spundown. Lo… | |
| 1.3.6.1.4.1.12925.1.2.0.30 | NotificationdiskOvertempAndSpundownNoDsk | current | Physical Disk with World Wide Name (WWN) <pd_wwn> has exceeded its temperature threshold (<disk_temp> C, limit <thres_temp> C) and it has been spundown. Locati… | |
| 1.3.6.1.4.1.12925.1.2.0.31 | NotificationcomponentStateChangeFailedHardware0x00600deX153 | current | Failed Hardware; Magazine <mag_id> Physical Disk <pd_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.32 | NotificationcomponentStateChangeMediaFailed0x00600deX156 | current | Media Failed; Magazine <mag_id> Physical Disk <pd_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.33 | NotificationcomponentStateChangeFailedHardware0x00600faX153 | current | Failed Hardware; Magazine <mag_id> Physical Disk <pd_id> Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.34 | NotificationcomponentStateChangeMediaFailed0x00600faX156 | current | Media Failed; Magazine <mag_id> Physical Disk <pd_id> Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.35 | NotificationcomponentStateChangeReplaceDrive0x00600faX70 | current | Replace Drive; Magazine <mag_id> Physical Disk <pd_id> Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.36 | NotificationdoubleNodeFailure | current | System is not able to recover from double node failure. | |
| 1.3.6.1.4.1.12925.1.2.0.37 | NotificationnodeRecoveryPowerfailEvent | current | Node recovery requires a powerfail to continue | |
| 1.3.6.1.4.1.12925.1.2.0.38 | NotificationlicenseKeyUsageLicenseExpired | current | License feature <feature_name> has expired. You are in violation of your 3PAR License Agreement. | |
| 1.3.6.1.4.1.12925.1.2.0.39 | NotificationsystemRecoveryNotificationAboutBadVolume | current | Powerfail recovery could not be performed for volume <prb_vname> with id <prb_vvid>. This may have caused loss of data for that volume. Use checkvv to check an… | |
| 1.3.6.1.4.1.12925.1.2.0.40 | NotificationbatteryStates | current | Battery states could not be read from the configuration file. System cache is disabled. | |
| 1.3.6.1.4.1.12925.1.2.0.41 | NotificationsystemRecoveryStalledDueToUnstartedVvs | current | System recovery stalled due to unstarted vvs. Num vvs: <pfs_num_vvs>. | |
| 1.3.6.1.4.1.12925.1.2.0.42 | NotificationunexpectedEncryptionStateOnNodeDrive | current | System is waiting for the encryption state of nodes <wait_nodes> to become valid. If this state persists, check existing alerts for more information. | |
| 1.3.6.1.4.1.12925.1.2.0.43 | NotificationideDiskErrorNodeShutdown | current | Node <nid> is being shutdown by the system because it had internal drive errors. | |
| 1.3.6.1.4.1.12925.1.2.0.44 | NotificationideDiskErrorNodeNotShutdown | current | Node <nid> is not being shutdown by the system even though there are internal drive errors because it is the last node left alive. | |
| 1.3.6.1.4.1.12925.1.2.0.45 | NotificationideDiskErrorNodeNotShutdownLdsCannotBeServed | current | Node <nid> is not being shutdown by the system even though there are internal drive errors because some LDs cannot be served by the remaining nodes. | |
| 1.3.6.1.4.1.12925.1.2.0.46 | NotificationideDiskErrorNodeReboot | current | Node <nid> is being rebooted by the system because it had internal drive errors. | |
| 1.3.6.1.4.1.12925.1.2.0.47 | NotificationauthenticationFailure | current | <number of fails> authentication failures in <n> secs | |
| 1.3.6.1.4.1.12925.1.2.0.48 | NotificationnodeIsOffline | current | Node <node_id> is offline | |
| 1.3.6.1.4.1.12925.1.2.0.49 | NotificationmemoryUsageInformation | current | Memory usage critical: MemTotal: <memtotal>K MemFree: <memfree>K Buffers: <buffers>K Cached: <cached>K SwapCached: <swapcached>K Active: <active>K Inactive: <i… | |
| 1.3.6.1.4.1.12925.1.2.0.50 | NotificationclusterThermalShutdown | current | Node <Node_ID>, due to high temperature conditions, the storage system is being shutdown. | |
| 1.3.6.1.4.1.12925.1.2.0.51 | NotificationnodeNeedsToShutdown | current | THERMAL SHUTDOWN, node: <node_id> | |
| 1.3.6.1.4.1.12925.1.2.0.52 | NotificationslabMemoryUsageOverLimit | current | SlabUsage:: critical status=<report_status> Totals:: memory=<slab_tot_mem_kb>KB count=<slab_tot_ct> activeCount=<slab_tot_active_ct> largestUseSlabs(count=<sla… | |
| 1.3.6.1.4.1.12925.1.2.0.53 | NotificationsystemReporterCmpPerformanceMajorAlert | current | System Reporter threshold alert <cmp_str_data> with condition <cmp_valstr1> has been satisfied by cmp on node <cmp_valstr0> with value(s) <cmp_valstr2>. | |
| 1.3.6.1.4.1.12925.1.2.0.54 | NotificationsystemReporterCpuPerformanceMajorAlert | current | System Reporter threshold alert <cpu_str_data> with condition <cpu_valstr1> has been satisfied by cpu on node <cpu_valstr0> with value(s) <cpu_valstr2>. | |
| 1.3.6.1.4.1.12925.1.2.0.55 | NotificationsystemReporterLinkPerformanceMajorAlert | current | System Reporter threshold alert <link_str_data> with condition <link_valstr1> has been satisfied by link on node <link_valstr0> with value(s) <link_valstr2>. | |
| 1.3.6.1.4.1.12925.1.2.0.56 | NotificationcmpThreshold | current | CMP usage on node [[hw_node]] has exceeded <threshold>%. | |
| 1.3.6.1.4.1.12925.1.2.0.57 | NotificationsystemReporterCachePerformanceMajorAlert | current | System Reporter threshold alert <cache_str_data> with condition <cache_valstr1> has been satisfied by cache on node <cache_valstr0> with value(s) <cache_valstr… | |
| 1.3.6.1.4.1.12925.1.2.0.58 | NotificationcomponentStateChangeTimeOfDayBatteryFailure | current | Time-Of-Day Battery Failure; Node <node_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.59 | NotificationcomponentStateChangeCpuOverheating | current | CPU Overheating; Node <node_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.60 | NotificationcomponentStateChangeNodeOfflineDueToFailure0x01a00deX13 | current | Node Offline Due to Failure; Node <node_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.61 | NotificationcomponentStateChangeCpuDead0x01a00deX19 | current | CPU Dead; Node <node_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.62 | NotificationcomponentStateChangeNodeFanModule0Failed0x01a00deX25 | current | Node Fan Module 0 Failed; Node <node_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.63 | NotificationcomponentStateChangeNodeFanModule0PowerFault0x01a00deX28 | current | Node Fan Module 0 Power Fault; Node <node_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.64 | NotificationcomponentStateChangeNodeFanModule0UnderLimit | current | Node Fan Module 0 Under Limit; Node <node_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.65 | NotificationcomponentStateChangeNodeThermalState | current | Node Thermal State; Node <node_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.66 | NotificationcomponentStateChangeNodeFanModule1Failed0x01a00deX33 | current | Node Fan Module 1 Failed; Node <node_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.67 | NotificationcomponentStateChangeNodeFanModule1PowerFault0x01a00deX35 | current | Node Fan Module 1 Power Fault; Node <node_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.68 | NotificationcomponentStateChangeNodeOfflineDueToFailure0x01a00faX13 | current | Node Offline Due to Failure; Node <node_id> Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.69 | NotificationcomponentStateChangeCpuDead0x01a00faX19 | current | CPU Dead; Node <node_id> Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.70 | NotificationcomponentStateChangeNodeFanModule0Failed0x01a00faX25 | current | Node Fan Module 0 Failed; Node <node_id> Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.71 | NotificationcomponentStateChangeNodeFanModule0PowerFault0x01a00faX28 | current | Node Fan Module 0 Power Fault; Node <node_id> Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.72 | NotificationcomponentStateChangeUncorrectableMemoryError | current | Uncorrectable Memory Error; Node <node_id> Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.73 | NotificationcomponentStateChangeNodeThermalShutdown | current | Node Thermal Shutdown; Node <node_id> Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.74 | NotificationcomponentStateChangeNodeFanModule1Failed0x01a00faX33 | current | Node Fan Module 1 Failed; Node <node_id> Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.75 | NotificationcomponentStateChangeNodeFanModule1PowerFault0x01a00faX35 | current | Node Fan Module 1 Power Fault; Node <node_id> Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.76 | NotificationcomponentStateChangeMultipleUncorrectableMemoryError | current | Multiple Uncorrectable Memory Error; Node <node_id> Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.77 | NotificationcomponentStateChangeDcFailed0x01b00faX1 | current | DC Failed; Node <node_id> Power Supply <power_supply_id> Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.78 | NotificationcomponentStateChangeOverTemperature | current | Over Temperature; Node <node_id> Power Supply <power_supply_id> Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.79 | NotificationcomponentStateChangeAcFailed | current | AC Failed; Node <node_id> Power Supply <power_supply_id> Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.80 | NotificationcomponentStateChangeFanFailed0x01b00faX3 | current | Fan Failed; Node <node_id> Power Supply <power_supply_id> Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.81 | NotificationcomponentStateChangeTemperatureUnderWarningThreshold0x01e00deX1 | current | Temperature Under Warning Threshold; Cage <cage_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.82 | NotificationcomponentStateChangeOperatorsPanelFailed | current | Operators Panel Failed; Cage <cage_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.83 | NotificationcomponentStateChangeOperatorsPanelWarning | current | Operators Panel Warning; Cage <cage_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.84 | NotificationcomponentStateChangeUnsupportedCage | current | Unsupported Cage; Cage <cage_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.85 | NotificationcomponentStateChangeTemperatureUnderWarningThreshold0x01e00faX1 | current | Temperature Under Warning Threshold; Cage <cage_id> Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.86 | NotificationcomponentStateChangeTemperatureUnderFailureThreshold | current | Temperature Under Failure Threshold; Cage <cage_id> Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.87 | NotificationcomponentStateChangeTemperatureOverWarningThreshold | current | Temperature Over Warning Threshold; Cage <cage_id> Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.88 | NotificationcomponentStateChangeInaccessible | current | Inaccessible; Cage <cage_id> Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.89 | NotificationcomponentStateChangeTemperatureOverFailureThreshold | current | Temperature Over Failure Threshold; Cage <cage_id> Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.90 | NotificationcomponentStateChangePortBypassed | current | Port Bypassed; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.91 | NotificationcomponentStateChangeNotready | current | Notready; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.92 | NotificationcomponentStateChangeMissing0x01f00deX129 | current | Missing; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.93 | NotificationcomponentStateChangeInvalidConnections | current | Invalid connections; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.94 | NotificationcomponentStateChangeNotAvailableForAllocations | current | Not Available For Allocations; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.95 | NotificationcomponentStateChangeOldFirmware | current | Old Firmware; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.96 | NotificationcomponentStateChangeDisabledAPort | current | Disabled A Port; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.97 | NotificationcomponentStateChangeMissingAPort | current | Missing A Port; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.98 | NotificationcomponentStateChangeErrorsOnAPort | current | Errors on A Port; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.99 | NotificationcomponentStateChangeProlongedMissingAPort | current | Prolonged Missing A Port; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.100 | NotificationcomponentStateChangeDisabledBPort | current | Disabled B Port; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.101 | NotificationcomponentStateChangeMissingBPort | current | Missing B Port; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.102 | NotificationcomponentStateChangeErrorsOnBPort | current | Errors on B Port; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.103 | NotificationcomponentStateChangeProlongedMissingBPort | current | Prolonged Missing B Port; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.104 | NotificationcomponentStateChangeOverTemperatureWarning | current | Over Temperature Warning; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.105 | NotificationcomponentStateChangeOverTemperatureAlert | current | Over Temperature Alert; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.106 | NotificationcomponentStateChangeInvalidMedia | current | Invalid Media; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.107 | NotificationcomponentStateChangeFailedHardware0x01f00deX153 | current | Failed Hardware; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.108 | NotificationcomponentStateChangeSmartThresholdExceeded | current | Smart Threshold Exceeded; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.109 | NotificationcomponentStateChangeMultipleChunkletsMediaBad | current | Multiple Chunklets Media Bad; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.110 | NotificationcomponentStateChangeMediaFailed0x01f00deX156 | current | Media Failed; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.111 | NotificationcomponentStateChangeIncreasedErrorCount | current | Increased Error Count; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.112 | NotificationcomponentStateChangeDifThresholdExceeded | current | DIF Threshold Exceeded; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.113 | NotificationcomponentStateChangeProlongedNotReady | current | Prolonged Not Ready; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.114 | NotificationcomponentStateChangeNoValidPorts | current | No Valid Ports; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.115 | NotificationcomponentStateChangeInquiryFailed | current | Inquiry Failed; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.116 | NotificationcomponentStateChangeUnitReadyFailed | current | Unit Ready Failed; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.117 | NotificationcomponentStateChangeReadCapacityFailed | current | Read Capacity Failed; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.118 | NotificationcomponentStateChangeWriteLabelFailed | current | Write Label Failed; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.119 | NotificationcomponentStateChangeModePageUpdateFailed | current | Mode Page Update Failed; Magazine <mag_id> Physical Disk <pd_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.120 | NotificationcomponentStateChangeReadLabelFailed | current | Read Label Failed; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.121 | NotificationcomponentStateChangeMediumFormatCorrupted | current | Medium Format Corrupted; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.122 | NotificationcomponentStateChangeLowWearLevelRemaining | current | Low Wear Level Remaining; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.123 | NotificationcomponentStateChangeMiscompare | current | Miscompare; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.124 | NotificationcomponentStateChangeInvalidCage | current | Invalid Cage; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.125 | NotificationcomponentStateChangeSlowDrive | current | Slow Drive; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.126 | NotificationcomponentStateChangeServicing | current | Servicing; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.127 | NotificationcomponentStateChangeDriveErrorBitSet | current | Drive Error Bit Set; Disk <wwn_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.128 | NotificationcomponentStateChangeFailedHardware0x01f00faX153 | current | Failed Hardware; Disk <wwn_id> Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.129 | NotificationcomponentStateChangeMediaFailed0x01f00faX156 | current | Media Failed; Disk <wwn_id> Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.130 | NotificationcomponentStateChangeReplaceDrive0x01f00faX70 | current | Replace Drive; Disk <wwn_id> Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.131 | NotificationinternalErrorInAuthenticationLibrary | current | Authentication internal error. Client address <IPaddr> port <port> | |
| 1.3.6.1.4.1.12925.1.2.0.132 | NotificationassertBatteryFail | current | Node <node_id> PS <power_supply_id> Battery <battery_id>: Battery Failed during battery test. | |
| 1.3.6.1.4.1.12925.1.2.0.133 | NotificationcomponentStateChangeExpired | current | Expired; Node <node_id> [Power Supply <power_supply_id>] Battery <battery_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.134 | NotificationcomponentStateChangeChargingFailed | current | Charging Failed; Node <node_id> [Power Supply <power_supply_id>] Battery <battery_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.135 | NotificationcomponentStateChangeInternalError | current | Internal Error; Node <node_id> [Power Supply <power_supply_id>] Battery <battery_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.136 | NotificationcomponentStateChangeLoadSharingFailed | current | Load Sharing Failed; Node <node_id> [Power Supply <power_supply_id>] Battery <battery_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.137 | NotificationcomponentStateChangeFanFailed0x02200deX6 | current | Fan Failed; Node <node_id> [Power Supply <power_supply_id>] Battery <battery_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.138 | NotificationcomponentStateChangeDcFailed0x02200deX7 | current | DC Failed; Node <node_id> [Power Supply <power_supply_id>] Battery <battery_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.139 | NotificationcomponentStateChangeChargerFailed | current | Charger Failed; Node <node_id> [Power Supply <power_supply_id>] Battery <battery_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.140 | NotificationcomponentStateChangeFailed | current | Failed; Node <node_id> [Power Supply <power_supply_id>] Battery <battery_id> Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.141 | NotificationportShutdownOnFatalError | current | Port <port_id> shut down: <time_shutdown> | |
| 1.3.6.1.4.1.12925.1.2.0.142 | NotificationhostPortIsDown | current | Host port (<node>:<slot>:<port>) is down (<reason>) | |
| 1.3.6.1.4.1.12925.1.2.0.143 | NotificationremoteCopyLinkStatus | current | The Remote Copy link <remote_copy_link_process_name> has changed its status to <status> | |
| 1.3.6.1.4.1.12925.1.2.0.144 | NotificationreplicationResourceUsageExceededGroupLogging | current | Remote copy group <rm_grp_name> with ID <rm_grp_id> has transitioned to logging mode due to resource limitations. | |
| 1.3.6.1.4.1.12925.1.2.0.145 | NotificationreplicationResourceUsageExceededGroupStopped | current | Remote copy group <rm_grp_name> with ID <rm_grp_id> has been stopped due to resource limitations. | |
| 1.3.6.1.4.1.12925.1.2.0.146 | NotificationreplicationResourcesRestoredGroupTransitionFromLoggingFailur | current | Remote copy group <rm_grp_name> with ID <rm_grp_id> could not transition out of logging state when replication resources became available, retrying. | |
| 1.3.6.1.4.1.12925.1.2.0.147 | NotificationnoAdminNetworkInterfaceDiscovered | current | The administrative network interface has failed on node [[hw_node]]. The system cannot be managed from this node. | |
| 1.3.6.1.4.1.12925.1.2.0.148 | NotificationtpVvAllocationSizeLimit | current | Thin provisioned VV <name> has reached reserved allocation <limit> of <XX>G (<yy>% of <ZZ>G) | |
| 1.3.6.1.4.1.12925.1.2.0.149 | NotificationsnapshotSpaceAllocationSizeLimit | current | Reserved snapshot space for VV <name> has reached allocation <limit> of <XX>G (<yy>% of <ZZ>G) | |
| 1.3.6.1.4.1.12925.1.2.0.150 | NotificationcpgGrowthLimit | current | CPG <cpg name> SA space has reached allocation <limit> of <XX>G. | |
| 1.3.6.1.4.1.12925.1.2.0.151 | NotificationtpVvAllocationFailure | current | Thin provisioned VV <name> <unable to> allocate <SA or SD or SD_2> space from CPG <cpg name> | |
| 1.3.6.1.4.1.12925.1.2.0.152 | NotificationsnapshotSpaceAllocationFailure | current | Snapshot space for VV <VV name> <unable to> allocate <SA or SD or SD_2> space from CPG <cpg name> | |
| 1.3.6.1.4.1.12925.1.2.0.153 | NotificationfcRawSpaceAllocation75Alert | current | Total <FC> raw space usage at <ZZ> (above <75>% of total <total>) | |
| 1.3.6.1.4.1.12925.1.2.0.154 | NotificationfcRawSpaceAllocation85Alert | current | Total <FC> raw space usage at <ZZ> (above <85>% of total <total>) | |
| 1.3.6.1.4.1.12925.1.2.0.155 | NotificationfcRawSpaceAllocation95Alert | current | Total <FC> raw space usage at <ZZ> (above <95>% of total <total>) | |
| 1.3.6.1.4.1.12925.1.2.0.156 | NotificationnlRawSpaceAllocation75Alert | current | Total <NL> raw space usage at <space used> (above <75>% of total <total space>) | |
| 1.3.6.1.4.1.12925.1.2.0.157 | NotificationnlRawSpaceAllocation85Alert | current | Total <NL> raw space usage at <ZZ> (above <85>% of total <total>) | |
| 1.3.6.1.4.1.12925.1.2.0.158 | NotificationnlRawSpaceAllocation95Alert | current | Total <NL> raw space usage at <ZZ> (above <95>% of total <total>) | |
| 1.3.6.1.4.1.12925.1.2.0.159 | NotificationssdRawSpaceAllocation75Alert | current | Total <SSD> raw space usage at <ZZ> (above <75>% of total <total>) | |
| 1.3.6.1.4.1.12925.1.2.0.160 | NotificationssdRawSpaceAllocation85Alert | current | Total <SSD> raw space usage at <space used> (above <85>% of total <total space>) | |
| 1.3.6.1.4.1.12925.1.2.0.161 | NotificationssdRawSpaceAllocation95Alert | current | Total <SSD> raw space usage at <ZZ> (above <95>% of total <total>) | |
| 1.3.6.1.4.1.12925.1.2.0.162 | NotificationpreservedDataLdsAreFull | current | Preserved data LDs are full. No more preserved data can be handled. | |
| 1.3.6.1.4.1.12925.1.2.0.163 | NotificationcomponentStateChangePowerSupplyFanWarning | current | Power Supply Fan Warning; Cage <cage_id> Power Supply <power_supply_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.164 | NotificationcomponentStateChangePowerSupplyOff | current | Power Supply Off; Cage <cage_id> Power Supply <power_supply_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.165 | NotificationcomponentStateChangePowerSupplyFailed0x02b00faX1 | current | Power Supply Failed; Cage <cage_id> Power Supply <power_supply_id> Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.166 | NotificationcomponentStateChangePowerSupplyFailed0x02b00faX1026 | current | Power Supply Failed; Cage <cage_id> Power Supply <power_supply_id> Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.167 | NotificationcomponentStateChangePowerSupplyWarning | current | Power Supply Warning; Cage <cage_id> Power Supply <power_supply_id> Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.168 | NotificationcomponentStateChangePowerSupplyFanNotPresent | current | Power Supply Fan Not Present; Cage <cage_id> Power Supply <power_supply_id> Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.169 | NotificationcomponentStateChangePowerSupplyFanNotAvailable | current | Power Supply Fan Not Available; Cage <cage_id> Power Supply <power_supply_id> Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.170 | NotificationcomponentStateChangePowerSupplyNotAvailable | current | Power Supply Not Available; Cage <cage_id> Power Supply <power_supply_id> Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.171 | NotificationcomponentStateChangePowerSupplyAcFailed | current | Power Supply AC Failed; Cage <cage_id> Power Supply <power_supply_id> Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.172 | NotificationcomponentStateChangeInterfaceCardFailed0x02d00deX1026 | current | Interface Card Failed; Cage <cage_id> Interface Card <interface_card_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.173 | NotificationcomponentStateChangeCpuFirmwareNotCurrent | current | CPU Firmware Not Current; Cage <cage_id> Interface Card <interface_card_id> Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.174 | NotificationcomponentStateChangeInterfaceCardFailed0x02d00faX1026 | current | Interface Card Failed; Cage <cage_id> Interface Card <interface_card_id> Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.175 | NotificationcomponentStateChangeInterfaceCardWarning | current | Interface Card Warning; Cage <cage_id> Interface Card <interface_card_id> Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.176 | NotificationcomponentStateChangeMissing0x03500faX1 | current | Missing; Cage <cage_id> Magazine <mag_id> Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.177 | NotificationcomponentStateChangeOffloopPowerSupplyFailure | current | Offloop, Power Supply Failure; Cage <cage_id> Magazine <mag_id> Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.178 | NotificationwriteCacheAvailability | current | System write cache availability is degraded. | |
| 1.3.6.1.4.1.12925.1.2.0.179 | NotificationcomponentStateChangeVolumeUnsyncedRequiresAFullResyncSinceLd | current | Volume Unsynced - requires a full resync since ldck is in progress; Remote Copy Volume <volume_id>(<volume_name>) Degraded (<list of: State String {State Value… | |
| 1.3.6.1.4.1.12925.1.2.0.180 | NotificationcomponentStateChangeResyncSnapshotBecameStaleFullSyncRequire | current | Resync Snapshot Became Stale - full sync required; Remote Copy Volume <volume_id>(<volume_name>) Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.181 | NotificationcomponentStateChangeVolumeGroupUnsyncedDidNotTakeSnapshotsWh | current | Volume Group Unsynced - did not take snapshots while stopping group; Remote Copy Volume <volume_id>(<volume_name>) Degraded (<list of: State String {State Valu… | |
| 1.3.6.1.4.1.12925.1.2.0.182 | NotificationcomponentStateChangeVolumeUnsyncedSecondaryVolumeWasNotMarke | current | Volume Unsynced - secondary volume was not marked as in-sync; Remote Copy Volume <volume_id>(<volume_name>) Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.183 | NotificationcomponentStateChangeVolumeUnsyncedVolumeWasUnavailableWhenGr | current | Volume Unsynced - volume was unavailable when group was stopped; Remote Copy Volume <volume_id>(<volume_name>) Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.184 | NotificationcomponentStateChangeVolumeUnsyncedNodeOrSysmgrFailure | current | Volume Unsynced - node or sysmgr failure; Remote Copy Volume <volume_id>(<volume_name>) Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.185 | NotificationcomponentStateChangeVolumeUnsyncedPromoteOfSnapshotFailed | current | Volume Unsynced - promote of snapshot failed; Remote Copy Volume <volume_id>(<volume_name>) Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.186 | NotificationcomponentStateChangeVolumeUnsyncedCouldNotTakeSnapshotDuring | current | Volume Unsynced - could not take snapshot during sysmgr startup; Remote Copy Volume <volume_id>(<volume_name>) Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.187 | NotificationcomponentStateChangeWriteToSecondaryVolumeFailed | current | Write To Secondary Volume Failed; Remote Copy Volume <volume_id>(<volume_name>) Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.188 | NotificationcomponentStateChangeSyncFailed | current | Sync Failed; Remote Copy Volume <volume_id>(<volume_name>) Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.189 | NotificationcomponentStateChangeSyncFailedCouldNotTakeLocalSnapshots | current | Sync Failed - could not take local snapshots; Remote Copy Volume Group <group_id>(<group_name>) Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.190 | NotificationcomponentStateChangeSyncFailedCouldNotTakeRemoteSnapshots | current | Sync Failed - could not take remote snapshots; Remote Copy Volume Group <group_id>(<group_name>) Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.191 | NotificationcomponentStateChangeSyncFailedCouldNotCommunicateWithTarget | current | Sync Failed - could not communicate with target; Remote Copy Volume Group <group_id>(<group_name>) Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.192 | NotificationcomponentStateChangeSyncFailedSynchronizationSnapshotHasBeen | current | Sync Failed - synchronization snapshot has been deleted; Remote Copy Volume Group <group_id>(<group_name>) Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.193 | NotificationcomponentStateChangeResyncFailedResynchronizationSnapshotHas | current | Resync Failed - resynchronization snapshot has been deleted; Remote Copy Volume Group <group_id>(<group_name>) Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.194 | NotificationcomponentStateChangeNotAllVolumesInGroupAreInSync | current | Not All Volumes In Group Are In Sync; Remote Copy Volume Group <group_id>(<group_name>) Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.195 | NotificationcomponentStateChangeResyncFailedVolumeIsCurrentlySyncing | current | Resync Failed - volume is currently syncing; Remote Copy Volume Group <group_id>(<group_name>) Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.196 | NotificationcomponentStateChangeAllLinksToTargetAreDown | current | All Links To Target Are Down; Remote Copy Target <target_id>(<target_name>) Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.197 | NotificationcomponentStateChangeNotAllConnectionsAreUp | current | Not All Connections Are Up; Remote Copy Link <link_id>(<link_name>) Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.198 | NotificationcomponentStateChangeDownDueToSendErrorOrMissingHeartbeat | current | Down Due To Send Error Or Missing Heartbeat; Remote Copy Link <link_id>(<link_name>) Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.199 | NotificationcomponentStateChangeMultipleLinkDownErrorsWithin24Hours | current | Multiple Link Down Errors Within 24 Hours; Remote Copy Link <link_id>(<link_name>) Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.200 | NotificationcomponentStateChangeLinkHasBeenDownForMoreThan4Hours | current | Link Has Been Down For More Than 4 Hours; Remote Copy Link <link_id>(<link_name>) Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.201 | NotificationfreeNodeDiskSpaceLow | current | Node <nid> free disk space is below acceptable limits: root <free_space>MB altroot <alt_space>MB common <comm_space>MB. | |
| 1.3.6.1.4.1.12925.1.2.0.202 | NotificationnodeDriveIsEncryptedButEncryptionIsNotEnabledOnTheSystem | current | Node drive for node <hw_node> drive <driveid> with WWN <sw_wwn> has encryption enabled, but encryption is not enabled on the system. | |
| 1.3.6.1.4.1.12925.1.2.0.203 | NotificationencryptionIsEnabledOnTheSystemButTheNodeDriveIsNotEncrypted | current | Node drive for node <hw_node> drive <driveid> with WWN <sw_wwn> is not encrypted, but encryption is enabled on the system. | |
| 1.3.6.1.4.1.12925.1.2.0.204 | NotificationunableToDoIOToTheNodeDrive | current | Unable to do I/O to the node drive for node <hw_node> drive <driveid> with WWN <sw_wwn>. | |
| 1.3.6.1.4.1.12925.1.2.0.205 | NotificationsyslogNodeDriveFailureMessageMonitoring | current | [[hw_node]] syslog received dual boot drive failure message. Problem exists on device: <nodedrivesdxdev_name>, on sata port: <nodedrivesataport_name> | |
| 1.3.6.1.4.1.12925.1.2.0.206 | NotificationperiodicProcMdstatMonitoringDetectedDegradedNodeDriveRaid | current | [[hw_node]] /proc/mdstat detected degraded node drive raid. Problem exists on device: <nodedrivesdxdev_name>, on sata port: <nodedrivesataport_name> | |
| 1.3.6.1.4.1.12925.1.2.0.207 | NotificationprocessNameAppearsUnresponsive | current | <name> appears to be unresponsive. | |
| 1.3.6.1.4.1.12925.1.2.0.208 | NotificationprocessEventHandlingAppearsUnresponsive | current | <name> event handling appears to be unresponsive. | |
| 1.3.6.1.4.1.12925.1.2.0.209 | NotificationpatrolDataCacheDimmUerr | current | Node <node_id>, Data Cache DIMM <dimm_id> is failing. Uncorrectable Error. | |
| 1.3.6.1.4.1.12925.1.2.0.210 | NotificationcontrolCacheDimmTemperature | current | Node <node_id> Control Cache DIMM <dimm_id> overheating (<temp> C). | |
| 1.3.6.1.4.1.12925.1.2.0.211 | NotificationcomponentStateChangeCageBatteryEndOfLife | current | Cage Battery End of Life; Cage <cage_id> Cage Battery <battery_id> Degraded (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.212 | NotificationcomponentStateChangeCageBatteryFailed | current | Cage Battery Failed; Cage <cage_id> Cage Battery <battery_id> Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.213 | NotificationcomponentStateChangeCageBatteryNotPresent | current | Cage Battery Not Present; Cage <cage_id> Cage Battery <battery_id> Failed (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.214 | NotificationcomponentStateChangeNodeControlCacheDimmFailure | current | Node Control Cache DIMM Failure; Node <node_id>, Contol_Cache_DIMM failed, <DIMM_INFO> (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.215 | NotificationcomponentStateChangeNodeDataCacheDimmFailure | current | Node Data Cache DIMM Failure; Node <node_id>, Data_Cache_DIMM failed, <DIMM_INFO> (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.216 | NotificationcomponentStateChangeNodeIdeDriveFailure | current | Node IDE Drive Failure; Node <node_id>, IDE_DRIVE failed, Instance: <dev_num> (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.217 | NotificationcomponentStateChangeNodeHbaFailure | current | Node HBA Failure; Node <node_id>, HBA failed, Instance: <dev_num> (<list of: State String {State Value}>) | |
| 1.3.6.1.4.1.12925.1.2.0.218 | NotificationsedIsFromTheWrongSystem | current | A self-encrypting drive with WWN <sw_wwn> belongs to another system: <name> | |
| 1.3.6.1.4.1.12925.1.2.0.219 | NotificationsedHasTheWrongKey | current | A self-encrypting drive with WWN <sw_wwn> has an unrecognized encryption key | |
| 1.3.6.1.4.1.12925.1.2.0.220 | NotificationsedIsPresentButEncryptionIsNotEnabled | current | A self-encrypting drive with WWN <sw_wwn> is encrypted, but encryption is not enabled on the system. | |
| 1.3.6.1.4.1.12925.1.2.0.221 | NotificationlkmIsInAnUnknownState | current | The local Key Manager is in an invalid state | |
| 1.3.6.1.4.1.12925.1.2.0.222 | NotificationnodesvrUnresponsiveDuringDarsvrStartup | current | The encryption management service is unavailable due to excessive failures getting encryption status from nodesvr during darsvr startup. If encryption is enabl… | |
| 1.3.6.1.4.1.12925.1.2.0.223 | NotificationnodesvrUnresponsiveDuringFipsvrStartup | current | The encryption management service is unavailable due to excessive failures getting encryption status from nodesvr during fipsvr startup. If encryption is enabl… | |
| 1.3.6.1.4.1.12925.1.2.0.224 | NotificationfipsvrUnableToStartInFipsMode | current | The encryption management service is unavailable because fipsvr failed to start up in FIPS mode. If encryption is enabled on this system, drive replacement is … | |
| 1.3.6.1.4.1.12925.1.2.0.225 | NotificationfailedToSuccessfullyCommunicateWithEkmAtStartup | current | The encryption management service is unavailable because communication failed to the External Key Manager during startup. If encryption is enabled on this syst… | |
| 1.3.6.1.4.1.12925.1.2.0.9999 | NotificationcheckSnmpAlert | current | check snmp test alert | |
| 1.3.6.1.4.1.12925.1.3 | NodeinservGeneric | |||
| 1.3.6.1.4.1.12925.1.3.1 | ScalarmanagerIp | accessible-for-notify | current | The IP address of the SNMP manager from which the SNMP authentication failure trap originated. |
| 1.3.6.1.4.1.12925.1.4 | IdentityinservAgentCaps | current | InServ agent profile | |
| 1.3.6.1.4.1.12925.1.4.1 | ComplianceinservAgentCapability | read-only | current | HPE 3PAR agent capability. Please note that the HPE 3PAR agent supports snmpObsoleteGroup in SNMPv2-MIB instead of snmpGroup. |
| 1.3.6.1.4.1.12925.1.4.2 | ComplianceinservAgentCapabilityV02 | read-only | current | HPE 3PAR agent capability. Please note that the HPE 3PAR agent supports snmpObsoleteGroup in SNMPv2-MIB instead of snmpGroup. |
| 1.3.6.1.4.1.12925.1.7 | TablealertTable | not-accessible | current | Contains critical information in notifications sent to SNMP managers. This information is translated from alerts generated by the system. |
| 1.3.6.1.4.1.12925.1.7.1 | RowalertEntry | not-accessible | current | Row Description |
| 1.3.6.1.4.1.12925.1.7.1.1 | Columnindex | read-only | current | Index to access entries in alert table. However, the table is empty most of the time because the entry is deleted after sending the trap |
| 1.3.6.1.4.1.12925.1.7.1.2 | Columnseverity | read-only | current | Severity of the alert. The enumeration is borrowed from Common Information Model (CIM): 0 - fatal: indicates an error occurred, but it's too late to take any a… |
| 1.3.6.1.4.1.12925.1.7.1.3 | ColumntimeOccurred | read-only | current | The local time and date when the alert occurred. The format is '%Y-%m-%d %H:%M:%S %Z'. Where: %Y - year including century, %m - two digit month, %d - two digit… |
| 1.3.6.1.4.1.12925.1.7.1.4 | ColumnnodeID | read-only | current | The node the alert was posted on. The node number starts from 0. The maximum number of node is 32. |
| 1.3.6.1.4.1.12925.1.7.1.5 | Columncomponent | read-only | current | The component which the event applies to; for example, power supply, SCSI disk, BIOS, cage etc... |
| 1.3.6.1.4.1.12925.1.7.1.6 | Columndetails | read-only | current | Additional detailed description of the alert. The detail may include things like disk number, cage number the alert applies to. |
| 1.3.6.1.4.1.12925.1.7.1.7 | Columnid | read-only | current | Unique ID that identifies the instance of an alert. This is a unique number that is generated each time an alert is generated by the system. |
| 1.3.6.1.4.1.12925.1.7.1.8 | ColumnmessageCode | read-only | current | Message code is assigned to a particular event type, and is encoded as a 32-bit number in the following way: The MSB 8 bits are reserved. The next 8 bits repre… |
| 1.3.6.1.4.1.12925.1.7.1.9 | Columnstate | read-only | current | This provides information about the state of the alert. new - new alert generated by the system acknowledged - an administrator has acknowledged the alert but … |
| 1.3.6.1.4.1.12925.1.7.1.10 | ColumnserialNumber | read-only | current | The serial-number of the HPE 3PAR InServ system |
| 1.3.6.1.4.1.12925.1.7.1.11 | ColumncatalogKey | read-only | current | The extension of the message code. It's used for the lookup of HPGT information. |
| 1.3.6.1.4.1.12925.1.7.1.12 | ColumndetailedMessage | read-only | current | The extension of the details. It provides more specific details of error condition. |
| 1.3.6.1.4.1.12925.1.7.1.13 | Columntier | read-only | current | The event tier. It provides more details on the type of event. |
| 1.3.6.1.4.1.12925.1.7.1.14 | ColumnsparePartNumber | read-only | current | The spare part number from events in the Hardware replacement or Hardware check tiers. |
| 1.3.6.1.4.1.12925.1.7.1.15 | ColumnsysName | read-only | current | The name of the storage system. |
| 1.3.6.1.4.1.12925.1.8 | NotificationalertNotify | current | Alert notification contains details about an event that may affect system operations and performance. The details include all columns defined in alertTable. | |
| 1.3.6.1.4.1.12925.1.9 | NodecpuStatsMIB | |||
| 1.3.6.1.4.1.12925.1.9.1 | NodecpuStatsComplianceGroups | |||
| 1.3.6.1.4.1.12925.1.9.1.1 | GroupnodeCpuStatsGroup | current | nodeCpuStatsTable columns representing the overall cpu statistics for each node | |
| 1.3.6.1.4.1.12925.1.9.1.2 | GroupcpuStatsGroup | current | cpuStatsTable columns representing the statistics for each cpu in a node | |
| 1.3.6.1.4.1.12925.1.9.2 | NodecpuStatsCompliances | |||
| 1.3.6.1.4.1.12925.1.9.2.1 | CompliancecpuStatsCompliance | current | A collection of objects providing basic instrumentation for a HPE 3PAR server. | |
| 1.3.6.1.4.1.12925.1.9.3 | NodecpuStatsObjs | |||
| 1.3.6.1.4.1.12925.1.9.3.1 | TablenodeCpuStatsTable | not-accessible | current | The nodeCpuStatsTable contains overall CPU related statistics for each node in a HPE 3PAR StoreServe system. |
| 1.3.6.1.4.1.12925.1.9.3.1.1 | RownodeCpuStatsEntry | not-accessible | current | An entry in the nodeCpuStatsTable. |
| 1.3.6.1.4.1.12925.1.9.3.1.1.1 | ColumnnodeCpuStatsIndex | not-accessible | current | 3PAR Node ID plus 1. |
| 1.3.6.1.4.1.12925.1.9.3.1.1.2 | ColumnnodeCpuStatsNs | read-only | current | Node nano seconds when stats were read. |
| 1.3.6.1.4.1.12925.1.9.3.1.1.3 | ColumnnodeCpuStatsNumCpus | read-only | current | Number of CPUs in the node. |
| 1.3.6.1.4.1.12925.1.9.3.1.1.4 | ColumnnodeCpuStatsInterupts | read-only | current | Total number of interrupts serviced on the node since boot time. |
| 1.3.6.1.4.1.12925.1.9.3.1.1.5 | ColumnnodeCpuStatsContextSwitches | read-only | current | Total number of context switches across all CPUs on the node since boot time. |
| 1.3.6.1.4.1.12925.1.9.3.1.1.6 | ColumnnodeCpuStatsBootTime | read-only | current | Time in the epoch when the node was booted. The epoch started at midnight on January 1 1970 UTC. |
| 1.3.6.1.4.1.12925.1.9.3.1.1.7 | ColumnnodeCpuStatsProcs | read-only | current | Total number of processes created since the node was booted. |
| 1.3.6.1.4.1.12925.1.9.3.2 | TablecpuStatsTable | not-accessible | current | The cpuStatsTable contains statistics for each CPU in a node in a HPE 3PAR StoreServe system. |
| 1.3.6.1.4.1.12925.1.9.3.2.1 | RowcpuStatsEntry | not-accessible | current | An entry in the cpuStatsTable. |
| 1.3.6.1.4.1.12925.1.9.3.2.1.1 | ColumncpuStatsIndex | not-accessible | current | The index of the CPU starting at 1. |
| 1.3.6.1.4.1.12925.1.9.3.2.1.2 | ColumncpuStatsUser | read-only | current | Total time spent executing user processes on the cpu since the node booted. |
| 1.3.6.1.4.1.12925.1.9.3.2.1.3 | ColumncpuStatsSys | read-only | current | Total time spend executing system threads on the cpu since the node booted. |
| 1.3.6.1.4.1.12925.1.9.3.2.1.4 | ColumncpuStatsIdle | read-only | current | Total idle time on the cpu since the node booted. |
| 1.3.6.1.4.1.12925.1.9.3.2.1.5 | ColumncpuStatsNodeNs | read-only | current | Node nano seconds when stats were read. |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| ThreeparLongDisplayString | OCTET STRING inserv OBJECT-IDENTITY STATUS current DESCRIPTION "InServ product" ::= { threepar 1 } | current | Use this textual convention for display string that can be longer than 255 characters, since DisplayString is defined in SNMPv2-TC as having a maximum size of only 255. A size range will have to be specified when using … |