MIB Viewer

ThreeParMIB

295 objects
This file specifies management information interface for all HPE 3PAR, Primera, Alletra and GreenLake for Block Storage products. This information is normally used by any management software that utilizes SNMP as management standard. The SNMP agent inside the device provides the specified information.
Imported Objects
SNMPv2-CONFAGENT-CAPABILITIES MODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP
SNMPv2-SMICounter64 enterprises Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-IDENTITY OBJECT-TYPE Unsigned32
SNMPv2-TCDisplayString TEXTUAL-CONVENTION
OIDNameAccessStatusDescription
1.3.6.1.4.1.12925IdentitythreeparThis file specifies management information interface for all HPE 3PAR, Primera, Alletra and GreenLake for Block Storage products. This information is normally …
1.3.6.1.4.1.12925.1IdentityinservcurrentInServ product
1.3.6.1.4.1.12925.1.1NodeinservConf
1.3.6.1.4.1.12925.1.1.1NodeinservGroups
1.3.6.1.4.1.12925.1.1.1.1NodealertNotifyGroups
1.3.6.1.4.1.12925.1.1.1.1.1GroupalertNotifyGroupcurrentalertTable columns representing details about an event that may affect system operations and performance.
1.3.6.1.4.1.12925.1.1.1.1.2GroupalertNotifyEventsGroupcurrentContains alertNotify events for system alerts.
1.3.6.1.4.1.12925.1.1.1.2NodestoreServAlertsGroups
1.3.6.1.4.1.12925.1.1.1.2.1GroupstoreServAlertsGroupcurrentalertTable columns representing details about an event that may affect system operations and performance.
1.3.6.1.4.1.12925.1.1.1.2.2GroupstoreServAlertsEventscurrentA collection of events for storeServAlerts
1.3.6.1.4.1.12925.1.1.1.3Nodesnmpv2TrapExtensionGroups
1.3.6.1.4.1.12925.1.1.1.3.1Groupsnmpv2TrapExtensionObjectsGroupcurrentThe extra object bindings extending selected standard SNMPv2 traps: managerIP extends the authenticationFailure trap.
1.3.6.1.4.1.12925.1.1.1.3.2Groupsnmpv2TrapExtensionEventsGroupcurrentSNMPv2 traps extended with extra object bindings by HPE 3PAR.
1.3.6.1.4.1.12925.1.1.2NodeinservCompls
1.3.6.1.4.1.12925.1.1.2.1NodealertNotifyCompliances
1.3.6.1.4.1.12925.1.1.2.1.1CompliancealertNotifyCompliancecurrentA collection of objects providing basic notifications for a HPE 3PAR server.
1.3.6.1.4.1.12925.1.1.2.2NodestoreServAlertsCompliances
1.3.6.1.4.1.12925.1.1.2.2.1CompliancestoreServAlertsCompliancecurrentA collection of objects providing basic instrumentation for a HPE 3PAR server.
1.3.6.1.4.1.12925.1.1.2.3Nodesnmpv2TrapExtensionCompliances
1.3.6.1.4.1.12925.1.1.2.3.1Compliancesnmpv2TrapExtensionCompliancecurrentCompliance for SNMPv2 standard traps that are extended by HPE 3PAR.
1.3.6.1.4.1.12925.1.2NodeinservEvents
1.3.6.1.4.1.12925.1.2.0IdentitystoreServAlertscurrentNamed alerts with descriptions
1.3.6.1.4.1.12925.1.2.0.1NotificationactiveVlunLimitExceededcurrentThere are currently <num_luns> active VLUNs, which is above the supported limit of <max_luns> active VLUNs
1.3.6.1.4.1.12925.1.2.0.2NotificationfcPortErrorcurrentPort <portnum> Failed (Shutdown Due To Too Many Firmware Cores).
1.3.6.1.4.1.12925.1.2.0.3NotificationportDeviceCountExceededcurrent[[sw_port]], supported device count exceeded for port.
1.3.6.1.4.1.12925.1.2.0.4NotificationdiskPortHasExceededIoErrorThresholdcurrentDisk [[sw_port]] has exceeded a threshold tracking IO errors. <count> errors have been seen in one hour.
1.3.6.1.4.1.12925.1.2.0.5NotificationcomponentStateChangeTargetModePortWentOfflinecurrentTarget Mode Port Went Offline; Port <node>:<slot>:<port> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.6NotificationcomponentStateChangeTooManyInitiatorscurrentToo many initiators; Port <node>:<slot>:<port> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.7NotificationmetadataInconsistencyInAVvcurrent[[vvol]] Volume not started due to metadata inconsistency; manual check required.
1.3.6.1.4.1.12925.1.2.0.8NotificationvlmapCountExceedsThresholdcurrentVV <vv_name> (<vv_id>) exceeds vlmap count threshold 80% : AR1 <count> AR5 <count> AR5_SEC <count> USR <count>
1.3.6.1.4.1.12925.1.2.0.9NotificationflashcachePerformanceDegradationcurrentFlash Cache I/O times are slow on node: <node>.
1.3.6.1.4.1.12925.1.2.0.10NotificationmetadataInconsistencyInADeduplicationGroupcurrent<cpg_name> <cpg_id> Deduplication Group not started due to metadata inconsistency; manual check required.
1.3.6.1.4.1.12925.1.2.0.11NotificationvvUnrecoveredDifErrorcurrentData Integrity Field (DIF) detected inconsistency for [[vvol]]
1.3.6.1.4.1.12925.1.2.0.12NotificationcomponentStateChangeMaintenanceCheckRequiredcurrentMaintenance Check Required; Virtual Volume <vv_id>(<vv_name>) Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.13NotificationcomponentStateChangeLdsNotStartedcurrentLDs Not Started; Virtual Volume <vv_id>(<vv_name>) Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.14NotificationcomponentStateChangeCopyFailedcurrentCopy Failed; Virtual Volume <vv_id>(<vv_name>) Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.15NotificationcomponentStateChangeSnapdataInvalidcurrentSnapdata Invalid; Virtual Volume <vv_id>(<vv_name>) Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.16NotificationcomponentStateChangeInternalConsistencyErrorcurrentInternal Consistency Error; Virtual Volume <vv_id>(<vv_name>) Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.17NotificationcomponentStateChangeNeedsToBeCheckedcurrentNeeds To Be Checked; Virtual Volume <vv_id>(<vv_name>) Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.18NotificationcomponentStateChangePreservedcurrentPreserved; Virtual Volume <vv_id>(<vv_name>) Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.19NotificationcomponentStateChangeInvalidcurrentInvalid; Virtual Volume <vv_id>(<vv_name>) Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.20NotificationcomponentStateChangeStalecurrentStale; Virtual Volume <vv_id>(<vv_name>) Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.21NotificationldskHasFailedSetcurrentLD <ld_id>(<ld_name>) row <ld_row> set <ld_set> failed. Internal reason <reason>.
1.3.6.1.4.1.12925.1.2.0.22NotificationldAvailabilityHasReducedcurrentSome Logical Disks (LDs) in the system are running with reduced availability.
1.3.6.1.4.1.12925.1.2.0.23NotificationlogLdRaidSetFailurecurrentLog [[ld]] has a failed raid set: <set_num>. Reason <reason>.
1.3.6.1.4.1.12925.1.2.0.24NotificationdiskMonitorStoppedcurrentpd wwn <pd_wwn> has failed for too long. Disk monitoring has stopped on this disk.
1.3.6.1.4.1.12925.1.2.0.25NotificationsystemReporterPdPerformanceMajorAlertcurrentSystem Reporter threshold alert <pd_str_data> with condition <pd_valstr1> has been satisfied by pd <pd_valstr0> with value(s) <pd_valstr2>.
1.3.6.1.4.1.12925.1.2.0.26NotificationsystemOvertempcurrentSystem shutdown for over temp PDs, TOC quorum loss - <num> TOC drives are at or above their spin down temperatures.
1.3.6.1.4.1.12925.1.2.0.27NotificationdiskOvertempButNotSpundowncurrentPhysical Disk (PD) <pd_id> with World Wide Name (WWN) <pd_wwn> has exceeded its temperature threshold (<disk_temp> C, limit <thres_temp> C) but it could not be…
1.3.6.1.4.1.12925.1.2.0.28NotificationdiskOvertempAndSpundowncurrentPhysical Disk (PD) <pd_id> with World Wide Name (WWN) <pd_wwn> has exceeded its temperature threshold (<disk_temp> C, limit <thres_temp> C) and it has been spu…
1.3.6.1.4.1.12925.1.2.0.29NotificationdiskOvertempButNotSpundownNoDskcurrentPhysical Disk with World Wide Name (WWN) <pd_wwn> has exceeded its temperature threshold (<disk_temp> C, limit <thres_temp> C) but it could not be spundown. Lo…
1.3.6.1.4.1.12925.1.2.0.30NotificationdiskOvertempAndSpundownNoDskcurrentPhysical Disk with World Wide Name (WWN) <pd_wwn> has exceeded its temperature threshold (<disk_temp> C, limit <thres_temp> C) and it has been spundown. Locati…
1.3.6.1.4.1.12925.1.2.0.31NotificationcomponentStateChangeFailedHardware0x00600deX153currentFailed Hardware; Magazine <mag_id> Physical Disk <pd_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.32NotificationcomponentStateChangeMediaFailed0x00600deX156currentMedia Failed; Magazine <mag_id> Physical Disk <pd_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.33NotificationcomponentStateChangeFailedHardware0x00600faX153currentFailed Hardware; Magazine <mag_id> Physical Disk <pd_id> Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.34NotificationcomponentStateChangeMediaFailed0x00600faX156currentMedia Failed; Magazine <mag_id> Physical Disk <pd_id> Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.35NotificationcomponentStateChangeReplaceDrive0x00600faX70currentReplace Drive; Magazine <mag_id> Physical Disk <pd_id> Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.36NotificationdoubleNodeFailurecurrentSystem is not able to recover from double node failure.
1.3.6.1.4.1.12925.1.2.0.37NotificationnodeRecoveryPowerfailEventcurrentNode recovery requires a powerfail to continue
1.3.6.1.4.1.12925.1.2.0.38NotificationlicenseKeyUsageLicenseExpiredcurrentLicense feature <feature_name> has expired. You are in violation of your 3PAR License Agreement.
1.3.6.1.4.1.12925.1.2.0.39NotificationsystemRecoveryNotificationAboutBadVolumecurrentPowerfail recovery could not be performed for volume <prb_vname> with id <prb_vvid>. This may have caused loss of data for that volume. Use checkvv to check an…
1.3.6.1.4.1.12925.1.2.0.40NotificationbatteryStatescurrentBattery states could not be read from the configuration file. System cache is disabled.
1.3.6.1.4.1.12925.1.2.0.41NotificationsystemRecoveryStalledDueToUnstartedVvscurrentSystem recovery stalled due to unstarted vvs. Num vvs: <pfs_num_vvs>.
1.3.6.1.4.1.12925.1.2.0.42NotificationunexpectedEncryptionStateOnNodeDrivecurrentSystem is waiting for the encryption state of nodes <wait_nodes> to become valid. If this state persists, check existing alerts for more information.
1.3.6.1.4.1.12925.1.2.0.43NotificationideDiskErrorNodeShutdowncurrentNode <nid> is being shutdown by the system because it had internal drive errors.
1.3.6.1.4.1.12925.1.2.0.44NotificationideDiskErrorNodeNotShutdowncurrentNode <nid> is not being shutdown by the system even though there are internal drive errors because it is the last node left alive.
1.3.6.1.4.1.12925.1.2.0.45NotificationideDiskErrorNodeNotShutdownLdsCannotBeServedcurrentNode <nid> is not being shutdown by the system even though there are internal drive errors because some LDs cannot be served by the remaining nodes.
1.3.6.1.4.1.12925.1.2.0.46NotificationideDiskErrorNodeRebootcurrentNode <nid> is being rebooted by the system because it had internal drive errors.
1.3.6.1.4.1.12925.1.2.0.47NotificationauthenticationFailurecurrent<number of fails> authentication failures in <n> secs
1.3.6.1.4.1.12925.1.2.0.48NotificationnodeIsOfflinecurrentNode <node_id> is offline
1.3.6.1.4.1.12925.1.2.0.49NotificationmemoryUsageInformationcurrentMemory usage critical: MemTotal: <memtotal>K MemFree: <memfree>K Buffers: <buffers>K Cached: <cached>K SwapCached: <swapcached>K Active: <active>K Inactive: <i…
1.3.6.1.4.1.12925.1.2.0.50NotificationclusterThermalShutdowncurrentNode <Node_ID>, due to high temperature conditions, the storage system is being shutdown.
1.3.6.1.4.1.12925.1.2.0.51NotificationnodeNeedsToShutdowncurrentTHERMAL SHUTDOWN, node: <node_id>
1.3.6.1.4.1.12925.1.2.0.52NotificationslabMemoryUsageOverLimitcurrentSlabUsage:: critical status=<report_status> Totals:: memory=<slab_tot_mem_kb>KB count=<slab_tot_ct> activeCount=<slab_tot_active_ct> largestUseSlabs(count=<sla…
1.3.6.1.4.1.12925.1.2.0.53NotificationsystemReporterCmpPerformanceMajorAlertcurrentSystem Reporter threshold alert <cmp_str_data> with condition <cmp_valstr1> has been satisfied by cmp on node <cmp_valstr0> with value(s) <cmp_valstr2>.
1.3.6.1.4.1.12925.1.2.0.54NotificationsystemReporterCpuPerformanceMajorAlertcurrentSystem Reporter threshold alert <cpu_str_data> with condition <cpu_valstr1> has been satisfied by cpu on node <cpu_valstr0> with value(s) <cpu_valstr2>.
1.3.6.1.4.1.12925.1.2.0.55NotificationsystemReporterLinkPerformanceMajorAlertcurrentSystem Reporter threshold alert <link_str_data> with condition <link_valstr1> has been satisfied by link on node <link_valstr0> with value(s) <link_valstr2>.
1.3.6.1.4.1.12925.1.2.0.56NotificationcmpThresholdcurrentCMP usage on node [[hw_node]] has exceeded <threshold>%.
1.3.6.1.4.1.12925.1.2.0.57NotificationsystemReporterCachePerformanceMajorAlertcurrentSystem Reporter threshold alert <cache_str_data> with condition <cache_valstr1> has been satisfied by cache on node <cache_valstr0> with value(s) <cache_valstr…
1.3.6.1.4.1.12925.1.2.0.58NotificationcomponentStateChangeTimeOfDayBatteryFailurecurrentTime-Of-Day Battery Failure; Node <node_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.59NotificationcomponentStateChangeCpuOverheatingcurrentCPU Overheating; Node <node_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.60NotificationcomponentStateChangeNodeOfflineDueToFailure0x01a00deX13currentNode Offline Due to Failure; Node <node_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.61NotificationcomponentStateChangeCpuDead0x01a00deX19currentCPU Dead; Node <node_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.62NotificationcomponentStateChangeNodeFanModule0Failed0x01a00deX25currentNode Fan Module 0 Failed; Node <node_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.63NotificationcomponentStateChangeNodeFanModule0PowerFault0x01a00deX28currentNode Fan Module 0 Power Fault; Node <node_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.64NotificationcomponentStateChangeNodeFanModule0UnderLimitcurrentNode Fan Module 0 Under Limit; Node <node_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.65NotificationcomponentStateChangeNodeThermalStatecurrentNode Thermal State; Node <node_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.66NotificationcomponentStateChangeNodeFanModule1Failed0x01a00deX33currentNode Fan Module 1 Failed; Node <node_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.67NotificationcomponentStateChangeNodeFanModule1PowerFault0x01a00deX35currentNode Fan Module 1 Power Fault; Node <node_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.68NotificationcomponentStateChangeNodeOfflineDueToFailure0x01a00faX13currentNode Offline Due to Failure; Node <node_id> Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.69NotificationcomponentStateChangeCpuDead0x01a00faX19currentCPU Dead; Node <node_id> Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.70NotificationcomponentStateChangeNodeFanModule0Failed0x01a00faX25currentNode Fan Module 0 Failed; Node <node_id> Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.71NotificationcomponentStateChangeNodeFanModule0PowerFault0x01a00faX28currentNode Fan Module 0 Power Fault; Node <node_id> Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.72NotificationcomponentStateChangeUncorrectableMemoryErrorcurrentUncorrectable Memory Error; Node <node_id> Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.73NotificationcomponentStateChangeNodeThermalShutdowncurrentNode Thermal Shutdown; Node <node_id> Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.74NotificationcomponentStateChangeNodeFanModule1Failed0x01a00faX33currentNode Fan Module 1 Failed; Node <node_id> Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.75NotificationcomponentStateChangeNodeFanModule1PowerFault0x01a00faX35currentNode Fan Module 1 Power Fault; Node <node_id> Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.76NotificationcomponentStateChangeMultipleUncorrectableMemoryErrorcurrentMultiple Uncorrectable Memory Error; Node <node_id> Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.77NotificationcomponentStateChangeDcFailed0x01b00faX1currentDC Failed; Node <node_id> Power Supply <power_supply_id> Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.78NotificationcomponentStateChangeOverTemperaturecurrentOver Temperature; Node <node_id> Power Supply <power_supply_id> Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.79NotificationcomponentStateChangeAcFailedcurrentAC Failed; Node <node_id> Power Supply <power_supply_id> Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.80NotificationcomponentStateChangeFanFailed0x01b00faX3currentFan Failed; Node <node_id> Power Supply <power_supply_id> Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.81NotificationcomponentStateChangeTemperatureUnderWarningThreshold0x01e00deX1currentTemperature Under Warning Threshold; Cage <cage_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.82NotificationcomponentStateChangeOperatorsPanelFailedcurrentOperators Panel Failed; Cage <cage_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.83NotificationcomponentStateChangeOperatorsPanelWarningcurrentOperators Panel Warning; Cage <cage_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.84NotificationcomponentStateChangeUnsupportedCagecurrentUnsupported Cage; Cage <cage_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.85NotificationcomponentStateChangeTemperatureUnderWarningThreshold0x01e00faX1currentTemperature Under Warning Threshold; Cage <cage_id> Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.86NotificationcomponentStateChangeTemperatureUnderFailureThresholdcurrentTemperature Under Failure Threshold; Cage <cage_id> Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.87NotificationcomponentStateChangeTemperatureOverWarningThresholdcurrentTemperature Over Warning Threshold; Cage <cage_id> Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.88NotificationcomponentStateChangeInaccessiblecurrentInaccessible; Cage <cage_id> Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.89NotificationcomponentStateChangeTemperatureOverFailureThresholdcurrentTemperature Over Failure Threshold; Cage <cage_id> Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.90NotificationcomponentStateChangePortBypassedcurrentPort Bypassed; Disk <wwn_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.91NotificationcomponentStateChangeNotreadycurrentNotready; Disk <wwn_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.92NotificationcomponentStateChangeMissing0x01f00deX129currentMissing; Disk <wwn_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.93NotificationcomponentStateChangeInvalidConnectionscurrentInvalid connections; Disk <wwn_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.94NotificationcomponentStateChangeNotAvailableForAllocationscurrentNot Available For Allocations; Disk <wwn_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.95NotificationcomponentStateChangeOldFirmwarecurrentOld Firmware; Disk <wwn_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.96NotificationcomponentStateChangeDisabledAPortcurrentDisabled A Port; Disk <wwn_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.97NotificationcomponentStateChangeMissingAPortcurrentMissing A Port; Disk <wwn_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.98NotificationcomponentStateChangeErrorsOnAPortcurrentErrors on A Port; Disk <wwn_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.99NotificationcomponentStateChangeProlongedMissingAPortcurrentProlonged Missing A Port; Disk <wwn_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.100NotificationcomponentStateChangeDisabledBPortcurrentDisabled B Port; Disk <wwn_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.101NotificationcomponentStateChangeMissingBPortcurrentMissing B Port; Disk <wwn_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.102NotificationcomponentStateChangeErrorsOnBPortcurrentErrors on B Port; Disk <wwn_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.103NotificationcomponentStateChangeProlongedMissingBPortcurrentProlonged Missing B Port; Disk <wwn_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.104NotificationcomponentStateChangeOverTemperatureWarningcurrentOver Temperature Warning; Disk <wwn_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.105NotificationcomponentStateChangeOverTemperatureAlertcurrentOver Temperature Alert; Disk <wwn_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.106NotificationcomponentStateChangeInvalidMediacurrentInvalid Media; Disk <wwn_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.107NotificationcomponentStateChangeFailedHardware0x01f00deX153currentFailed Hardware; Disk <wwn_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.108NotificationcomponentStateChangeSmartThresholdExceededcurrentSmart Threshold Exceeded; Disk <wwn_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.109NotificationcomponentStateChangeMultipleChunkletsMediaBadcurrentMultiple Chunklets Media Bad; Disk <wwn_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.110NotificationcomponentStateChangeMediaFailed0x01f00deX156currentMedia Failed; Disk <wwn_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.111NotificationcomponentStateChangeIncreasedErrorCountcurrentIncreased Error Count; Disk <wwn_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.112NotificationcomponentStateChangeDifThresholdExceededcurrentDIF Threshold Exceeded; Disk <wwn_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.113NotificationcomponentStateChangeProlongedNotReadycurrentProlonged Not Ready; Disk <wwn_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.114NotificationcomponentStateChangeNoValidPortscurrentNo Valid Ports; Disk <wwn_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.115NotificationcomponentStateChangeInquiryFailedcurrentInquiry Failed; Disk <wwn_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.116NotificationcomponentStateChangeUnitReadyFailedcurrentUnit Ready Failed; Disk <wwn_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.117NotificationcomponentStateChangeReadCapacityFailedcurrentRead Capacity Failed; Disk <wwn_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.118NotificationcomponentStateChangeWriteLabelFailedcurrentWrite Label Failed; Disk <wwn_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.119NotificationcomponentStateChangeModePageUpdateFailedcurrentMode Page Update Failed; Magazine <mag_id> Physical Disk <pd_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.120NotificationcomponentStateChangeReadLabelFailedcurrentRead Label Failed; Disk <wwn_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.121NotificationcomponentStateChangeMediumFormatCorruptedcurrentMedium Format Corrupted; Disk <wwn_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.122NotificationcomponentStateChangeLowWearLevelRemainingcurrentLow Wear Level Remaining; Disk <wwn_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.123NotificationcomponentStateChangeMiscomparecurrentMiscompare; Disk <wwn_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.124NotificationcomponentStateChangeInvalidCagecurrentInvalid Cage; Disk <wwn_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.125NotificationcomponentStateChangeSlowDrivecurrentSlow Drive; Disk <wwn_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.126NotificationcomponentStateChangeServicingcurrentServicing; Disk <wwn_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.127NotificationcomponentStateChangeDriveErrorBitSetcurrentDrive Error Bit Set; Disk <wwn_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.128NotificationcomponentStateChangeFailedHardware0x01f00faX153currentFailed Hardware; Disk <wwn_id> Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.129NotificationcomponentStateChangeMediaFailed0x01f00faX156currentMedia Failed; Disk <wwn_id> Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.130NotificationcomponentStateChangeReplaceDrive0x01f00faX70currentReplace Drive; Disk <wwn_id> Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.131NotificationinternalErrorInAuthenticationLibrarycurrentAuthentication internal error. Client address <IPaddr> port <port>
1.3.6.1.4.1.12925.1.2.0.132NotificationassertBatteryFailcurrentNode <node_id> PS <power_supply_id> Battery <battery_id>: Battery Failed during battery test.
1.3.6.1.4.1.12925.1.2.0.133NotificationcomponentStateChangeExpiredcurrentExpired; Node <node_id> [Power Supply <power_supply_id>] Battery <battery_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.134NotificationcomponentStateChangeChargingFailedcurrentCharging Failed; Node <node_id> [Power Supply <power_supply_id>] Battery <battery_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.135NotificationcomponentStateChangeInternalErrorcurrentInternal Error; Node <node_id> [Power Supply <power_supply_id>] Battery <battery_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.136NotificationcomponentStateChangeLoadSharingFailedcurrentLoad Sharing Failed; Node <node_id> [Power Supply <power_supply_id>] Battery <battery_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.137NotificationcomponentStateChangeFanFailed0x02200deX6currentFan Failed; Node <node_id> [Power Supply <power_supply_id>] Battery <battery_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.138NotificationcomponentStateChangeDcFailed0x02200deX7currentDC Failed; Node <node_id> [Power Supply <power_supply_id>] Battery <battery_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.139NotificationcomponentStateChangeChargerFailedcurrentCharger Failed; Node <node_id> [Power Supply <power_supply_id>] Battery <battery_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.140NotificationcomponentStateChangeFailedcurrentFailed; Node <node_id> [Power Supply <power_supply_id>] Battery <battery_id> Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.141NotificationportShutdownOnFatalErrorcurrentPort <port_id> shut down: <time_shutdown>
1.3.6.1.4.1.12925.1.2.0.142NotificationhostPortIsDowncurrentHost port (<node>:<slot>:<port>) is down (<reason>)
1.3.6.1.4.1.12925.1.2.0.143NotificationremoteCopyLinkStatuscurrentThe Remote Copy link <remote_copy_link_process_name> has changed its status to <status>
1.3.6.1.4.1.12925.1.2.0.144NotificationreplicationResourceUsageExceededGroupLoggingcurrentRemote copy group <rm_grp_name> with ID <rm_grp_id> has transitioned to logging mode due to resource limitations.
1.3.6.1.4.1.12925.1.2.0.145NotificationreplicationResourceUsageExceededGroupStoppedcurrentRemote copy group <rm_grp_name> with ID <rm_grp_id> has been stopped due to resource limitations.
1.3.6.1.4.1.12925.1.2.0.146NotificationreplicationResourcesRestoredGroupTransitionFromLoggingFailurcurrentRemote copy group <rm_grp_name> with ID <rm_grp_id> could not transition out of logging state when replication resources became available, retrying.
1.3.6.1.4.1.12925.1.2.0.147NotificationnoAdminNetworkInterfaceDiscoveredcurrentThe administrative network interface has failed on node [[hw_node]]. The system cannot be managed from this node.
1.3.6.1.4.1.12925.1.2.0.148NotificationtpVvAllocationSizeLimitcurrentThin provisioned VV <name> has reached reserved allocation <limit> of <XX>G (<yy>% of <ZZ>G)
1.3.6.1.4.1.12925.1.2.0.149NotificationsnapshotSpaceAllocationSizeLimitcurrentReserved snapshot space for VV <name> has reached allocation <limit> of <XX>G (<yy>% of <ZZ>G)
1.3.6.1.4.1.12925.1.2.0.150NotificationcpgGrowthLimitcurrentCPG <cpg name> SA space has reached allocation <limit> of <XX>G.
1.3.6.1.4.1.12925.1.2.0.151NotificationtpVvAllocationFailurecurrentThin provisioned VV <name> <unable to> allocate <SA or SD or SD_2> space from CPG <cpg name>
1.3.6.1.4.1.12925.1.2.0.152NotificationsnapshotSpaceAllocationFailurecurrentSnapshot space for VV <VV name> <unable to> allocate <SA or SD or SD_2> space from CPG <cpg name>
1.3.6.1.4.1.12925.1.2.0.153NotificationfcRawSpaceAllocation75AlertcurrentTotal <FC> raw space usage at <ZZ> (above <75>% of total <total>)
1.3.6.1.4.1.12925.1.2.0.154NotificationfcRawSpaceAllocation85AlertcurrentTotal <FC> raw space usage at <ZZ> (above <85>% of total <total>)
1.3.6.1.4.1.12925.1.2.0.155NotificationfcRawSpaceAllocation95AlertcurrentTotal <FC> raw space usage at <ZZ> (above <95>% of total <total>)
1.3.6.1.4.1.12925.1.2.0.156NotificationnlRawSpaceAllocation75AlertcurrentTotal <NL> raw space usage at <space used> (above <75>% of total <total space>)
1.3.6.1.4.1.12925.1.2.0.157NotificationnlRawSpaceAllocation85AlertcurrentTotal <NL> raw space usage at <ZZ> (above <85>% of total <total>)
1.3.6.1.4.1.12925.1.2.0.158NotificationnlRawSpaceAllocation95AlertcurrentTotal <NL> raw space usage at <ZZ> (above <95>% of total <total>)
1.3.6.1.4.1.12925.1.2.0.159NotificationssdRawSpaceAllocation75AlertcurrentTotal <SSD> raw space usage at <ZZ> (above <75>% of total <total>)
1.3.6.1.4.1.12925.1.2.0.160NotificationssdRawSpaceAllocation85AlertcurrentTotal <SSD> raw space usage at <space used> (above <85>% of total <total space>)
1.3.6.1.4.1.12925.1.2.0.161NotificationssdRawSpaceAllocation95AlertcurrentTotal <SSD> raw space usage at <ZZ> (above <95>% of total <total>)
1.3.6.1.4.1.12925.1.2.0.162NotificationpreservedDataLdsAreFullcurrentPreserved data LDs are full. No more preserved data can be handled.
1.3.6.1.4.1.12925.1.2.0.163NotificationcomponentStateChangePowerSupplyFanWarningcurrentPower Supply Fan Warning; Cage <cage_id> Power Supply <power_supply_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.164NotificationcomponentStateChangePowerSupplyOffcurrentPower Supply Off; Cage <cage_id> Power Supply <power_supply_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.165NotificationcomponentStateChangePowerSupplyFailed0x02b00faX1currentPower Supply Failed; Cage <cage_id> Power Supply <power_supply_id> Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.166NotificationcomponentStateChangePowerSupplyFailed0x02b00faX1026currentPower Supply Failed; Cage <cage_id> Power Supply <power_supply_id> Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.167NotificationcomponentStateChangePowerSupplyWarningcurrentPower Supply Warning; Cage <cage_id> Power Supply <power_supply_id> Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.168NotificationcomponentStateChangePowerSupplyFanNotPresentcurrentPower Supply Fan Not Present; Cage <cage_id> Power Supply <power_supply_id> Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.169NotificationcomponentStateChangePowerSupplyFanNotAvailablecurrentPower Supply Fan Not Available; Cage <cage_id> Power Supply <power_supply_id> Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.170NotificationcomponentStateChangePowerSupplyNotAvailablecurrentPower Supply Not Available; Cage <cage_id> Power Supply <power_supply_id> Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.171NotificationcomponentStateChangePowerSupplyAcFailedcurrentPower Supply AC Failed; Cage <cage_id> Power Supply <power_supply_id> Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.172NotificationcomponentStateChangeInterfaceCardFailed0x02d00deX1026currentInterface Card Failed; Cage <cage_id> Interface Card <interface_card_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.173NotificationcomponentStateChangeCpuFirmwareNotCurrentcurrentCPU Firmware Not Current; Cage <cage_id> Interface Card <interface_card_id> Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.174NotificationcomponentStateChangeInterfaceCardFailed0x02d00faX1026currentInterface Card Failed; Cage <cage_id> Interface Card <interface_card_id> Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.175NotificationcomponentStateChangeInterfaceCardWarningcurrentInterface Card Warning; Cage <cage_id> Interface Card <interface_card_id> Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.176NotificationcomponentStateChangeMissing0x03500faX1currentMissing; Cage <cage_id> Magazine <mag_id> Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.177NotificationcomponentStateChangeOffloopPowerSupplyFailurecurrentOffloop, Power Supply Failure; Cage <cage_id> Magazine <mag_id> Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.178NotificationwriteCacheAvailabilitycurrentSystem write cache availability is degraded.
1.3.6.1.4.1.12925.1.2.0.179NotificationcomponentStateChangeVolumeUnsyncedRequiresAFullResyncSinceLdcurrentVolume Unsynced - requires a full resync since ldck is in progress; Remote Copy Volume <volume_id>(<volume_name>) Degraded (<list of: State String {State Value…
1.3.6.1.4.1.12925.1.2.0.180NotificationcomponentStateChangeResyncSnapshotBecameStaleFullSyncRequirecurrentResync Snapshot Became Stale - full sync required; Remote Copy Volume <volume_id>(<volume_name>) Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.181NotificationcomponentStateChangeVolumeGroupUnsyncedDidNotTakeSnapshotsWhcurrentVolume Group Unsynced - did not take snapshots while stopping group; Remote Copy Volume <volume_id>(<volume_name>) Degraded (<list of: State String {State Valu…
1.3.6.1.4.1.12925.1.2.0.182NotificationcomponentStateChangeVolumeUnsyncedSecondaryVolumeWasNotMarkecurrentVolume Unsynced - secondary volume was not marked as in-sync; Remote Copy Volume <volume_id>(<volume_name>) Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.183NotificationcomponentStateChangeVolumeUnsyncedVolumeWasUnavailableWhenGrcurrentVolume Unsynced - volume was unavailable when group was stopped; Remote Copy Volume <volume_id>(<volume_name>) Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.184NotificationcomponentStateChangeVolumeUnsyncedNodeOrSysmgrFailurecurrentVolume Unsynced - node or sysmgr failure; Remote Copy Volume <volume_id>(<volume_name>) Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.185NotificationcomponentStateChangeVolumeUnsyncedPromoteOfSnapshotFailedcurrentVolume Unsynced - promote of snapshot failed; Remote Copy Volume <volume_id>(<volume_name>) Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.186NotificationcomponentStateChangeVolumeUnsyncedCouldNotTakeSnapshotDuringcurrentVolume Unsynced - could not take snapshot during sysmgr startup; Remote Copy Volume <volume_id>(<volume_name>) Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.187NotificationcomponentStateChangeWriteToSecondaryVolumeFailedcurrentWrite To Secondary Volume Failed; Remote Copy Volume <volume_id>(<volume_name>) Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.188NotificationcomponentStateChangeSyncFailedcurrentSync Failed; Remote Copy Volume <volume_id>(<volume_name>) Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.189NotificationcomponentStateChangeSyncFailedCouldNotTakeLocalSnapshotscurrentSync Failed - could not take local snapshots; Remote Copy Volume Group <group_id>(<group_name>) Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.190NotificationcomponentStateChangeSyncFailedCouldNotTakeRemoteSnapshotscurrentSync Failed - could not take remote snapshots; Remote Copy Volume Group <group_id>(<group_name>) Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.191NotificationcomponentStateChangeSyncFailedCouldNotCommunicateWithTargetcurrentSync Failed - could not communicate with target; Remote Copy Volume Group <group_id>(<group_name>) Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.192NotificationcomponentStateChangeSyncFailedSynchronizationSnapshotHasBeencurrentSync Failed - synchronization snapshot has been deleted; Remote Copy Volume Group <group_id>(<group_name>) Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.193NotificationcomponentStateChangeResyncFailedResynchronizationSnapshotHascurrentResync Failed - resynchronization snapshot has been deleted; Remote Copy Volume Group <group_id>(<group_name>) Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.194NotificationcomponentStateChangeNotAllVolumesInGroupAreInSynccurrentNot All Volumes In Group Are In Sync; Remote Copy Volume Group <group_id>(<group_name>) Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.195NotificationcomponentStateChangeResyncFailedVolumeIsCurrentlySyncingcurrentResync Failed - volume is currently syncing; Remote Copy Volume Group <group_id>(<group_name>) Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.196NotificationcomponentStateChangeAllLinksToTargetAreDowncurrentAll Links To Target Are Down; Remote Copy Target <target_id>(<target_name>) Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.197NotificationcomponentStateChangeNotAllConnectionsAreUpcurrentNot All Connections Are Up; Remote Copy Link <link_id>(<link_name>) Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.198NotificationcomponentStateChangeDownDueToSendErrorOrMissingHeartbeatcurrentDown Due To Send Error Or Missing Heartbeat; Remote Copy Link <link_id>(<link_name>) Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.199NotificationcomponentStateChangeMultipleLinkDownErrorsWithin24HourscurrentMultiple Link Down Errors Within 24 Hours; Remote Copy Link <link_id>(<link_name>) Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.200NotificationcomponentStateChangeLinkHasBeenDownForMoreThan4HourscurrentLink Has Been Down For More Than 4 Hours; Remote Copy Link <link_id>(<link_name>) Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.201NotificationfreeNodeDiskSpaceLowcurrentNode <nid> free disk space is below acceptable limits: root <free_space>MB altroot <alt_space>MB common <comm_space>MB.
1.3.6.1.4.1.12925.1.2.0.202NotificationnodeDriveIsEncryptedButEncryptionIsNotEnabledOnTheSystemcurrentNode drive for node <hw_node> drive <driveid> with WWN <sw_wwn> has encryption enabled, but encryption is not enabled on the system.
1.3.6.1.4.1.12925.1.2.0.203NotificationencryptionIsEnabledOnTheSystemButTheNodeDriveIsNotEncryptedcurrentNode drive for node <hw_node> drive <driveid> with WWN <sw_wwn> is not encrypted, but encryption is enabled on the system.
1.3.6.1.4.1.12925.1.2.0.204NotificationunableToDoIOToTheNodeDrivecurrentUnable to do I/O to the node drive for node <hw_node> drive <driveid> with WWN <sw_wwn>.
1.3.6.1.4.1.12925.1.2.0.205NotificationsyslogNodeDriveFailureMessageMonitoringcurrent[[hw_node]] syslog received dual boot drive failure message. Problem exists on device: <nodedrivesdxdev_name>, on sata port: <nodedrivesataport_name>
1.3.6.1.4.1.12925.1.2.0.206NotificationperiodicProcMdstatMonitoringDetectedDegradedNodeDriveRaidcurrent[[hw_node]] /proc/mdstat detected degraded node drive raid. Problem exists on device: <nodedrivesdxdev_name>, on sata port: <nodedrivesataport_name>
1.3.6.1.4.1.12925.1.2.0.207NotificationprocessNameAppearsUnresponsivecurrent<name> appears to be unresponsive.
1.3.6.1.4.1.12925.1.2.0.208NotificationprocessEventHandlingAppearsUnresponsivecurrent<name> event handling appears to be unresponsive.
1.3.6.1.4.1.12925.1.2.0.209NotificationpatrolDataCacheDimmUerrcurrentNode <node_id>, Data Cache DIMM <dimm_id> is failing. Uncorrectable Error.
1.3.6.1.4.1.12925.1.2.0.210NotificationcontrolCacheDimmTemperaturecurrentNode <node_id> Control Cache DIMM <dimm_id> overheating (<temp> C).
1.3.6.1.4.1.12925.1.2.0.211NotificationcomponentStateChangeCageBatteryEndOfLifecurrentCage Battery End of Life; Cage <cage_id> Cage Battery <battery_id> Degraded (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.212NotificationcomponentStateChangeCageBatteryFailedcurrentCage Battery Failed; Cage <cage_id> Cage Battery <battery_id> Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.213NotificationcomponentStateChangeCageBatteryNotPresentcurrentCage Battery Not Present; Cage <cage_id> Cage Battery <battery_id> Failed (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.214NotificationcomponentStateChangeNodeControlCacheDimmFailurecurrentNode Control Cache DIMM Failure; Node <node_id>, Contol_Cache_DIMM failed, <DIMM_INFO> (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.215NotificationcomponentStateChangeNodeDataCacheDimmFailurecurrentNode Data Cache DIMM Failure; Node <node_id>, Data_Cache_DIMM failed, <DIMM_INFO> (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.216NotificationcomponentStateChangeNodeIdeDriveFailurecurrentNode IDE Drive Failure; Node <node_id>, IDE_DRIVE failed, Instance: <dev_num> (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.217NotificationcomponentStateChangeNodeHbaFailurecurrentNode HBA Failure; Node <node_id>, HBA failed, Instance: <dev_num> (<list of: State String {State Value}>)
1.3.6.1.4.1.12925.1.2.0.218NotificationsedIsFromTheWrongSystemcurrentA self-encrypting drive with WWN <sw_wwn> belongs to another system: <name>
1.3.6.1.4.1.12925.1.2.0.219NotificationsedHasTheWrongKeycurrentA self-encrypting drive with WWN <sw_wwn> has an unrecognized encryption key
1.3.6.1.4.1.12925.1.2.0.220NotificationsedIsPresentButEncryptionIsNotEnabledcurrentA self-encrypting drive with WWN <sw_wwn> is encrypted, but encryption is not enabled on the system.
1.3.6.1.4.1.12925.1.2.0.221NotificationlkmIsInAnUnknownStatecurrentThe local Key Manager is in an invalid state
1.3.6.1.4.1.12925.1.2.0.222NotificationnodesvrUnresponsiveDuringDarsvrStartupcurrentThe encryption management service is unavailable due to excessive failures getting encryption status from nodesvr during darsvr startup. If encryption is enabl…
1.3.6.1.4.1.12925.1.2.0.223NotificationnodesvrUnresponsiveDuringFipsvrStartupcurrentThe encryption management service is unavailable due to excessive failures getting encryption status from nodesvr during fipsvr startup. If encryption is enabl…
1.3.6.1.4.1.12925.1.2.0.224NotificationfipsvrUnableToStartInFipsModecurrentThe encryption management service is unavailable because fipsvr failed to start up in FIPS mode. If encryption is enabled on this system, drive replacement is …
1.3.6.1.4.1.12925.1.2.0.225NotificationfailedToSuccessfullyCommunicateWithEkmAtStartupcurrentThe encryption management service is unavailable because communication failed to the External Key Manager during startup. If encryption is enabled on this syst…
1.3.6.1.4.1.12925.1.2.0.9999NotificationcheckSnmpAlertcurrentcheck snmp test alert
1.3.6.1.4.1.12925.1.3NodeinservGeneric
1.3.6.1.4.1.12925.1.3.1ScalarmanagerIpaccessible-for-notifycurrentThe IP address of the SNMP manager from which the SNMP authentication failure trap originated.
1.3.6.1.4.1.12925.1.4IdentityinservAgentCapscurrentInServ agent profile
1.3.6.1.4.1.12925.1.4.1ComplianceinservAgentCapabilityread-onlycurrentHPE 3PAR agent capability. Please note that the HPE 3PAR agent supports snmpObsoleteGroup in SNMPv2-MIB instead of snmpGroup.
1.3.6.1.4.1.12925.1.4.2ComplianceinservAgentCapabilityV02read-onlycurrentHPE 3PAR agent capability. Please note that the HPE 3PAR agent supports snmpObsoleteGroup in SNMPv2-MIB instead of snmpGroup.
1.3.6.1.4.1.12925.1.7TablealertTablenot-accessiblecurrentContains critical information in notifications sent to SNMP managers. This information is translated from alerts generated by the system.
1.3.6.1.4.1.12925.1.7.1RowalertEntrynot-accessiblecurrentRow Description
1.3.6.1.4.1.12925.1.7.1.1Columnindexread-onlycurrentIndex to access entries in alert table. However, the table is empty most of the time because the entry is deleted after sending the trap
1.3.6.1.4.1.12925.1.7.1.2Columnseverityread-onlycurrentSeverity of the alert. The enumeration is borrowed from Common Information Model (CIM): 0 - fatal: indicates an error occurred, but it's too late to take any a…
1.3.6.1.4.1.12925.1.7.1.3ColumntimeOccurredread-onlycurrentThe local time and date when the alert occurred. The format is '%Y-%m-%d %H:%M:%S %Z'. Where: %Y - year including century, %m - two digit month, %d - two digit…
1.3.6.1.4.1.12925.1.7.1.4ColumnnodeIDread-onlycurrentThe node the alert was posted on. The node number starts from 0. The maximum number of node is 32.
1.3.6.1.4.1.12925.1.7.1.5Columncomponentread-onlycurrentThe component which the event applies to; for example, power supply, SCSI disk, BIOS, cage etc...
1.3.6.1.4.1.12925.1.7.1.6Columndetailsread-onlycurrentAdditional detailed description of the alert. The detail may include things like disk number, cage number the alert applies to.
1.3.6.1.4.1.12925.1.7.1.7Columnidread-onlycurrentUnique ID that identifies the instance of an alert. This is a unique number that is generated each time an alert is generated by the system.
1.3.6.1.4.1.12925.1.7.1.8ColumnmessageCoderead-onlycurrentMessage code is assigned to a particular event type, and is encoded as a 32-bit number in the following way: The MSB 8 bits are reserved. The next 8 bits repre…
1.3.6.1.4.1.12925.1.7.1.9Columnstateread-onlycurrentThis provides information about the state of the alert. new - new alert generated by the system acknowledged - an administrator has acknowledged the alert but …
1.3.6.1.4.1.12925.1.7.1.10ColumnserialNumberread-onlycurrentThe serial-number of the HPE 3PAR InServ system
1.3.6.1.4.1.12925.1.7.1.11ColumncatalogKeyread-onlycurrentThe extension of the message code. It's used for the lookup of HPGT information.
1.3.6.1.4.1.12925.1.7.1.12ColumndetailedMessageread-onlycurrentThe extension of the details. It provides more specific details of error condition.
1.3.6.1.4.1.12925.1.7.1.13Columntierread-onlycurrentThe event tier. It provides more details on the type of event.
1.3.6.1.4.1.12925.1.7.1.14ColumnsparePartNumberread-onlycurrentThe spare part number from events in the Hardware replacement or Hardware check tiers.
1.3.6.1.4.1.12925.1.7.1.15ColumnsysNameread-onlycurrentThe name of the storage system.
1.3.6.1.4.1.12925.1.8NotificationalertNotifycurrentAlert notification contains details about an event that may affect system operations and performance. The details include all columns defined in alertTable.
1.3.6.1.4.1.12925.1.9NodecpuStatsMIB
1.3.6.1.4.1.12925.1.9.1NodecpuStatsComplianceGroups
1.3.6.1.4.1.12925.1.9.1.1GroupnodeCpuStatsGroupcurrentnodeCpuStatsTable columns representing the overall cpu statistics for each node
1.3.6.1.4.1.12925.1.9.1.2GroupcpuStatsGroupcurrentcpuStatsTable columns representing the statistics for each cpu in a node
1.3.6.1.4.1.12925.1.9.2NodecpuStatsCompliances
1.3.6.1.4.1.12925.1.9.2.1CompliancecpuStatsCompliancecurrentA collection of objects providing basic instrumentation for a HPE 3PAR server.
1.3.6.1.4.1.12925.1.9.3NodecpuStatsObjs
1.3.6.1.4.1.12925.1.9.3.1TablenodeCpuStatsTablenot-accessiblecurrentThe nodeCpuStatsTable contains overall CPU related statistics for each node in a HPE 3PAR StoreServe system.
1.3.6.1.4.1.12925.1.9.3.1.1RownodeCpuStatsEntrynot-accessiblecurrentAn entry in the nodeCpuStatsTable.
1.3.6.1.4.1.12925.1.9.3.1.1.1ColumnnodeCpuStatsIndexnot-accessiblecurrent3PAR Node ID plus 1.
1.3.6.1.4.1.12925.1.9.3.1.1.2ColumnnodeCpuStatsNsread-onlycurrentNode nano seconds when stats were read.
1.3.6.1.4.1.12925.1.9.3.1.1.3ColumnnodeCpuStatsNumCpusread-onlycurrentNumber of CPUs in the node.
1.3.6.1.4.1.12925.1.9.3.1.1.4ColumnnodeCpuStatsInteruptsread-onlycurrentTotal number of interrupts serviced on the node since boot time.
1.3.6.1.4.1.12925.1.9.3.1.1.5ColumnnodeCpuStatsContextSwitchesread-onlycurrentTotal number of context switches across all CPUs on the node since boot time.
1.3.6.1.4.1.12925.1.9.3.1.1.6ColumnnodeCpuStatsBootTimeread-onlycurrentTime in the epoch when the node was booted. The epoch started at midnight on January 1 1970 UTC.
1.3.6.1.4.1.12925.1.9.3.1.1.7ColumnnodeCpuStatsProcsread-onlycurrentTotal number of processes created since the node was booted.
1.3.6.1.4.1.12925.1.9.3.2TablecpuStatsTablenot-accessiblecurrentThe cpuStatsTable contains statistics for each CPU in a node in a HPE 3PAR StoreServe system.
1.3.6.1.4.1.12925.1.9.3.2.1RowcpuStatsEntrynot-accessiblecurrentAn entry in the cpuStatsTable.
1.3.6.1.4.1.12925.1.9.3.2.1.1ColumncpuStatsIndexnot-accessiblecurrentThe index of the CPU starting at 1.
1.3.6.1.4.1.12925.1.9.3.2.1.2ColumncpuStatsUserread-onlycurrentTotal time spent executing user processes on the cpu since the node booted.
1.3.6.1.4.1.12925.1.9.3.2.1.3ColumncpuStatsSysread-onlycurrentTotal time spend executing system threads on the cpu since the node booted.
1.3.6.1.4.1.12925.1.9.3.2.1.4ColumncpuStatsIdleread-onlycurrentTotal idle time on the cpu since the node booted.
1.3.6.1.4.1.12925.1.9.3.2.1.5ColumncpuStatsNodeNsread-onlycurrentNode nano seconds when stats were read.
Type Definitions
NameSyntaxStatusDescription
ThreeparLongDisplayStringOCTET STRING inserv OBJECT-IDENTITY STATUS current DESCRIPTION "InServ product" ::= { threepar 1 }currentUse this textual convention for display string that can be longer than 255 characters, since DisplayString is defined in SNMPv2-TC as having a maximum size of only 255. A size range will have to be specified when using …