UPS2-MIB
80 objects
No module-level DESCRIPTION found.
Imported Objects
| CTRON-MIB-NAMES | ctUPS |
| RFC-1212 | OBJECT-TYPE |
| RFC1213-MIB | DisplayString |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.52.4.1.1.10.1 | NodeupsSystem | |||
| 1.3.6.1.4.1.52.4.1.1.10.1.1 | ScalarupsNumUPSs | read-only | mandatory | The number of UPSs available. |
| 1.3.6.1.4.1.52.4.1.1.10.2 | NodeupsId | |||
| 1.3.6.1.4.1.52.4.1.1.10.2.1 | TableupsIdTable | not-accessible | mandatory | A list of identification table entries. The number of entries is given by the value of upsNumUPSs. |
| 1.3.6.1.4.1.52.4.1.1.10.2.1.1 | RowupsIdEntry | not-accessible | mandatory | An entry containing objects for a particular UPS. |
| 1.3.6.1.4.1.52.4.1.1.10.2.1.1.1 | ColumnupsIndex | read-only | mandatory | A unique value which identifies a particular UPS. |
| 1.3.6.1.4.1.52.4.1.1.10.2.1.1.2 | ColumnupsName | read-write | mandatory | The UPS's name. A maximum of 8 characters may be specified. This object is initialized to the UPS's model name. |
| 1.3.6.1.4.1.52.4.1.1.10.2.1.1.3 | ColumnupsModelType | read-only | mandatory | The UPS's base model type. |
| 1.3.6.1.4.1.52.4.1.1.10.2.1.1.4 | ColumnupsFwVersion | read-only | mandatory | The UPS's firmware version. |
| 1.3.6.1.4.1.52.4.1.1.10.2.1.1.5 | ColumnupsSerialNumber | read-only | mandatory | The UPS's serial number as set at the factory. |
| 1.3.6.1.4.1.52.4.1.1.10.2.1.1.6 | ColumnupsManufDate | read-only | mandatory | The UPS's date of manufacture in the format mm/dd/yy. |
| 1.3.6.1.4.1.52.4.1.1.10.3 | NodeupsBattery | |||
| 1.3.6.1.4.1.52.4.1.1.10.3.1 | TableupsBatteryTable | not-accessible | mandatory | A list of battery table entries. The number of entries is given by the value of upsNumUPSs. |
| 1.3.6.1.4.1.52.4.1.1.10.3.1.1 | RowupsBatteryEntry | not-accessible | mandatory | An entry containing objects for a particular UPS. |
| 1.3.6.1.4.1.52.4.1.1.10.3.1.1.1 | ColumnupsBatteryCapacity | read-only | mandatory | The UPS's remaining battery capacity expressed as a percent of the fully charged condition. The value of this object is the actual percentage * 10 (that is, to… |
| 1.3.6.1.4.1.52.4.1.1.10.3.1.1.2 | ColumnupsBatteryVoltage | read-only | mandatory | The UPS's present battery voltage. The value of this object is the actual voltage * 100 (that is, to determine the actual voltage, divide the value of this obj… |
| 1.3.6.1.4.1.52.4.1.1.10.3.1.1.3 | ColumnupsBatteryTest | read-write | mandatory | This object may be written to initiate testing of the UPS's battery packs. Reading this object will always return a 0. |
| 1.3.6.1.4.1.52.4.1.1.10.3.1.1.4 | ColumnupsBatteryTestResult | read-only | mandatory | The result of the last battery test performed. |
| 1.3.6.1.4.1.52.4.1.1.10.3.1.1.5 | ColumnupsRunTimeCalibration | read-write | mandatory | This object may be written to initiate or terminate the test used to calibrate the returned run time value. This test will only run if battery capacity is 100%… |
| 1.3.6.1.4.1.52.4.1.1.10.3.1.1.6 | ColumnupsEstimatedRunTimeRemaining | read-only | mandatory | The UPS's estimated remaining run time in minutes. The UPS may be queried when operating in the on-line, bypass, or on-battery modes of operation. The run time… |
| 1.3.6.1.4.1.52.4.1.1.10.3.1.1.7 | ColumnupsTransferCause | read-only | mandatory | The reason for the most recent transfer to on-battery operation. |
| 1.3.6.1.4.1.52.4.1.1.10.3.1.1.8 | ColumnupsBatteryTestTime | read-write | mandatory | The frequency of execution of the UPS's automatic battery test. The test may be run immediately upon startup, upon startup and every 7 days thereafter, upon st… |
| 1.3.6.1.4.1.52.4.1.1.10.3.1.1.9 | ColumnupsLowBatteryWarning | read-write | mandatory | The interval between activation of the UPS's low battery alarm warnings and shutdown of the UPS. |
| 1.3.6.1.4.1.52.4.1.1.10.4 | NodeupsInput | |||
| 1.3.6.1.4.1.52.4.1.1.10.4.1 | TableupsInputTable | not-accessible | mandatory | A list of input table entries. The number of entries is given by the value of upsNumUPSs. |
| 1.3.6.1.4.1.52.4.1.1.10.4.1.1 | RowupsInputEntry | not-accessible | mandatory | An entry containing objects for a particular UPS. |
| 1.3.6.1.4.1.52.4.1.1.10.4.1.1.1 | ColumnupsInputUtilityVoltage | read-only | mandatory | The UPS's utility voltage version. |
| 1.3.6.1.4.1.52.4.1.1.10.4.1.1.2 | ColumnupsInputVoltage | read-only | mandatory | The UPS's measured utility input voltage. The value of this object is the actual voltage * 10 (that is, to determine the actual voltage, divide the value of th… |
| 1.3.6.1.4.1.52.4.1.1.10.4.1.1.3 | ColumnupsInputFailureSensitivity | read-write | mandatory | The sensitivity of the UPS to rapid changes in utility voltage (e.g., blackouts, spikes, or notches) or abnormal changes in utility frequency. |
| 1.3.6.1.4.1.52.4.1.1.10.4.1.1.4 | ColumnupsInputMaxVoltage | read-only | mandatory | The UPS's maximum input voltage recorded since this object was last read. The value of this object is the actual voltage * 10 (that is, to determine the actual… |
| 1.3.6.1.4.1.52.4.1.1.10.4.1.1.5 | ColumnupsInputMinVoltage | read-only | mandatory | The UPS's minimum input voltage recorded since this object was last read. The value of this object is the actual voltage * 10 (that is, to determine the actual… |
| 1.3.6.1.4.1.52.4.1.1.10.4.1.1.6 | ColumnupsInputFrequency | read-only | mandatory | The UPS's present internal operating frequency in Hz. The value of this object is the actual frequency * 100 (that is, to determine the actual frequency, divid… |
| 1.3.6.1.4.1.52.4.1.1.10.5 | NodeupsOutput | |||
| 1.3.6.1.4.1.52.4.1.1.10.5.1 | TableupsOutputTable | not-accessible | mandatory | A list of output table entries. The number of entries is given by the value of upsNumUPSs. |
| 1.3.6.1.4.1.52.4.1.1.10.5.1.1 | RowupsOutputEntry | not-accessible | mandatory | An entry containing objects for a particular UPS. |
| 1.3.6.1.4.1.52.4.1.1.10.5.1.1.1 | ColumnupsOutputVoltage | read-only | mandatory | The measured UPS output voltage. The value of this object is the actual voltage * 10 (that is, to determine the actual voltage, divide the value of this object… |
| 1.3.6.1.4.1.52.4.1.1.10.5.1.1.2 | ColumnupsOutputUtilityVoltage | read-write | mandatory | The UPS's current on-battery output voltage setting (valid for 220/230/240 Vac version UPSs only). For other version UPSs, reading this object will always retu… |
| 1.3.6.1.4.1.52.4.1.1.10.5.1.1.3 | ColumnupsOutputPower | read-only | mandatory | The UPS's output load represented as a percentage of full rated load in Watts. The value of this object is the actual percentage * 10 (that is, to determine th… |
| 1.3.6.1.4.1.52.4.1.1.10.6 | NodeupsStatus | |||
| 1.3.6.1.4.1.52.4.1.1.10.6.1 | TableupsStatusTable | not-accessible | mandatory | A list of status table entries. The number of entries is given by the value of upsNumUPSs. |
| 1.3.6.1.4.1.52.4.1.1.10.6.1.1 | RowupsStatusEntry | not-accessible | mandatory | An entry containing objects for a particular UPS. |
| 1.3.6.1.4.1.52.4.1.1.10.6.1.1.1 | ColumnupsStatusOperational | read-only | mandatory | This object contains 8 bits of information about the current operational status of the UPS. The bits are encoded as follows: BIT 7: 1=replace battery condition… |
| 1.3.6.1.4.1.52.4.1.1.10.6.1.1.2 | ColumnupsStatusFault | read-only | mandatory | This object contains 8 bits of information about the current fault conditions of the UPS. The bits are encoded as follows: BIT 7: 1=UPS fault - internal temper… |
| 1.3.6.1.4.1.52.4.1.1.10.6.1.1.3 | ColumnupsStatusTemp | read-only | mandatory | The UPS's present internal operating temperature in degrees Fahrenheit. The value of this object is the actual temperature * 10 (that is, to determine the actu… |
| 1.3.6.1.4.1.52.4.1.1.10.7 | NodeupsConfig | |||
| 1.3.6.1.4.1.52.4.1.1.10.7.1 | TableupsConfigTable | not-accessible | mandatory | A list of configuration table entries. The number of entries is given by the value of upsNumUPSs. |
| 1.3.6.1.4.1.52.4.1.1.10.7.1.1 | RowupsConfigEntry | not-accessible | mandatory | An entry containing objects for a particular UPS. |
| 1.3.6.1.4.1.52.4.1.1.10.7.1.1.1 | ColumnupsConfigAlarm | read-write | mandatory | The UPS's current audible alarm setting. The alarm may be set to activate immediately upon utility failure and for low battery condition, to activate 30 second… |
| 1.3.6.1.4.1.52.4.1.1.10.7.1.1.2 | ColumnupsConfigRestoreDefaults | read-write | mandatory | This object may be written to force the UPS to restore the factory default settings for most of the UPS's customizable parameters. Reading this object will alw… |
| 1.3.6.1.4.1.52.4.1.1.10.8 | NodeupsExtMeas | |||
| 1.3.6.1.4.1.52.4.1.1.10.8.1 | TableupsExtMeasTable | not-accessible | mandatory | A list of external measurement table entries. The number of entries is the number of available UPSs to which External Measurement Units are attached. |
| 1.3.6.1.4.1.52.4.1.1.10.8.1.1 | RowupsExtMeasEntry | not-accessible | mandatory | An entry containing objects for a particular UPS. |
| 1.3.6.1.4.1.52.4.1.1.10.8.1.1.1 | ColumnupsExtMeasFwVersion | read-only | mandatory | The External Measurement Unit's firmware version letter. |
| 1.3.6.1.4.1.52.4.1.1.10.8.1.1.2 | ColumnupsExtMeasTemp | read-only | mandatory | The local ambient temperature in degrees Fahrenheit as measured by the External Measurement Unit. The value of this object is the actual temperature * 100 (tha… |
| 1.3.6.1.4.1.52.4.1.1.10.8.1.1.3 | ColumnupsExtMeasHumidity | read-only | mandatory | The local ambient relative humidity in percent as measured by the External Measurement Unit. The value of this object is the actual humidity * 10 (that is, to … |
| 1.3.6.1.4.1.52.4.1.1.10.8.1.1.4 | ColumnupsExtMeasAlarmStatus | read-only | mandatory | This object contains 8 bits of information about the current alarm status of the External Measurement Unit. The bits are encoded as follows: BIT 7: 1=Upper tem… |
| 1.3.6.1.4.1.52.4.1.1.10.8.1.1.5 | ColumnupsExtMeasMaxTemp | read-write | mandatory | The upper temperature limit at which an alarm will be sent. |
| 1.3.6.1.4.1.52.4.1.1.10.8.1.1.6 | ColumnupsExtMeasMinTemp | read-write | mandatory | The lower temperature limit at which an alarm will be sent. |
| 1.3.6.1.4.1.52.4.1.1.10.8.1.1.7 | ColumnupsExtMeasMaxHumidity | read-write | mandatory | The upper humidity limit at which an alarm will be sent. |
| 1.3.6.1.4.1.52.4.1.1.10.8.1.1.8 | ColumnupsExtMeasMinHumidity | read-write | mandatory | The lower humidity limit at which an alarm will be sent. |
| 1.3.6.1.4.1.52.4.1.1.10.8.1.1.9 | ColumnupsExtMeasContact1AlarmControl | read-write | mandatory | The alarm enable state for the External Measurement Unit's contact input channel #1. If enabled, an alarm will be sent when contact input channel #1 has change… |
| 1.3.6.1.4.1.52.4.1.1.10.8.1.1.10 | ColumnupsExtMeasContact2AlarmControl | read-write | mandatory | The alarm enable state for the External Measurement Unit's contact input channel #2. If enabled, an alarm will be sent when contact input channel #2 has change… |
| 1.3.6.1.4.1.52.4.1.1.10.8.1.1.11 | ColumnupsExtMeasContact3AlarmControl | read-write | mandatory | The alarm enable state for the External Measurement Unit's contact input channel #3. If enabled, an alarm will be sent when contact input channel #3 has change… |
| 1.3.6.1.4.1.52.4.1.1.10.8.1.1.12 | ColumnupsExtMeasContact4AlarmControl | read-write | mandatory | The alarm enable state for the External Measurement Unit's contact input channel #4. If enabled, an alarm will be sent when contact input channel #4 has change… |
| 1.3.6.1.4.1.52.4.1.1.10.8.1.1.13 | ColumnupsExtMeasMaxTempAlarmControl | read-write | mandatory | The alarm enable state for the External Measurement Unit's upper temperature limit. If enabled, an alarm will be sent when the ambient temperature rises above … |
| 1.3.6.1.4.1.52.4.1.1.10.8.1.1.14 | ColumnupsExtMeasMinTempAlarmControl | read-write | mandatory | The alarm enable state for the External Measurement Unit's lower temperature limit. If enabled, an alarm will be sent when the ambient temperature falls below … |
| 1.3.6.1.4.1.52.4.1.1.10.8.1.1.15 | ColumnupsExtMeasMaxHumidityAlarmControl | read-write | mandatory | The alarm enable state for the External Measurement Unit's upper humidity limit. If enabled, an alarm will be sent when the ambient relative humidity rises abo… |
| 1.3.6.1.4.1.52.4.1.1.10.8.1.1.16 | ColumnupsExtMeasMinHumidityAlarmControl | read-write | mandatory | The alarm enable state for the External Measurement Unit's lower humidity limit. If enabled, an alarm will be sent when the ambient relative humidity falls bel… |
| 1.3.6.1.4.1.52.4.1.1.10.9 | NodeupsAddlFuncs | |||
| 1.3.6.1.4.1.52.4.1.1.10.9.1 | TableupsAddlFuncsTable | not-accessible | mandatory | A list of additional functions table entries. The number of entries is the number of available UPSs which are capable of supporting these additional functions. |
| 1.3.6.1.4.1.52.4.1.1.10.9.1.1 | RowupsAddlFuncsEntry | not-accessible | mandatory | An entry containing objects for a particular UPS. |
| 1.3.6.1.4.1.52.4.1.1.10.9.1.1.1 | ColumnupsAddlFuncsNumBatteryPacks | read-only | mandatory | The number of battery pack units connected to the UPS. |
| 1.3.6.1.4.1.52.4.1.1.10.9.1.1.2 | ColumnupsAddlFuncsNumBadBatteryPacks | read-only | mandatory | The number of bad (faulty) battery pack units connected to the UPS. |
| 1.3.6.1.4.1.52.4.1.1.10.9.1.1.3 | ColumnupsAddlFuncsOutputCurrent | read-only | mandatory | The true rms load current drawn from the UPS. The value of this object is the actual amperage * 100 (that is, to determine the actual amperage, divide the valu… |
| 1.3.6.1.4.1.52.4.1.1.10.9.1.1.4 | ColumnupsAddlFuncsOutputApparentPower | read-only | mandatory | The UPS's output load represented as a percentage of full rated load in Volt-Amps. The value of this object is the actual percentage * 10 (that is, to determin… |
| 1.3.6.1.4.1.52.4.1.1.10.9.1.1.5 | ColumnupsAddlFuncsStatusOperational | read-only | mandatory | This object contains 8 bits of information about the current operational status of the UPS. The bits are encoded as follows: BIT 7: 1=UPS ready to power load u… |
| 1.3.6.1.4.1.52.4.1.1.10.9.1.1.6 | ColumnupsAddlFuncsStatusFault | read-only | mandatory | This object contains 8 bits of information about the current fault conditions of the UPS. The bits are encoded as follows: BIT 7: reserved for future use BIT 6… |
| 1.3.6.1.4.1.52.4.1.1.10.9.1.1.7 | ColumnupsAddlFuncsConfigPassword | read-write | mandatory | The password that controls access to the UPS's LCD display. A maximum of 4 characters may be entered. |
| 1.3.6.1.4.1.52.4.1.1.10.9.1.1.8 | ColumnupsAddlFuncsConfigDisable | read-write | mandatory | This object may be written to immediately shut down the UPS, requiring a manual reset. Reading this object will always return a 0. |
| 1.3.6.1.4.1.52.4.1.1.10.9.1.1.9 | ColumnupsAddlFuncsConfigBypass | read-write | mandatory | This object may be written to cause the UPS to transfer to or from the bypass mode. Reading this object will always return a 0. |