VERTIV-V5-MIB
584 objects
The MIB for Vertiv products
Imported Objects
| SNMP-FRAMEWORK-MIB | SnmpAdminString |
| SNMPv2-MIB | sysName |
| SNMPv2-SMI | enterprises Gauge32 Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-IDENTITY OBJECT-TYPE |
| SNMPv2-TC | DisplayString MacAddress TruthValue |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.21239 | Identityvertiv | The MIB for Vertiv products | ||
| 1.3.6.1.4.1.21239.5 | Nodev5 | |||
| 1.3.6.1.4.1.21239.5.2 | Nodeimd | |||
| 1.3.6.1.4.1.21239.5.2.1 | NodedeviceInfo | |||
| 1.3.6.1.4.1.21239.5.2.1.1 | ScalarproductTitle | read-only | current | Product name |
| 1.3.6.1.4.1.21239.5.2.1.2 | ScalarproductVersion | read-only | current | Product version |
| 1.3.6.1.4.1.21239.5.2.1.3 | ScalarproductFriendlyName | read-only | current | User-assigned name |
| 1.3.6.1.4.1.21239.5.2.1.4 | ScalarproductMacAddress | read-only | current | Product's unique MAC address |
| 1.3.6.1.4.1.21239.5.2.1.6 | ScalardeviceCount | read-only | current | Total number of devices on unit |
| 1.3.6.1.4.1.21239.5.2.1.7 | ScalartemperatureUnits | read-write | current | Current units for temperature/dewpoint values: 0 = Degrees Fahrenheit 1 = Degrees Celsius |
| 1.3.6.1.4.1.21239.5.2.1.8 | ScalarproductModelNumber | read-only | current | Product model number (factory-assigned) |
| 1.3.6.1.4.1.21239.5.2.1.9 | ScalarproductPartNumber | read-only | current | Product part number (factory-assigned) |
| 1.3.6.1.4.1.21239.5.2.1.10 | ScalarproductSerialNumber | read-only | current | Product serial number (factory-assigned) |
| 1.3.6.1.4.1.21239.5.2.1.11 | ScalarproductPlatform | read-only | current | Product platform |
| 1.3.6.1.4.1.21239.5.2.1.12 | ScalarproductHostname | read-only | current | Product hostname |
| 1.3.6.1.4.1.21239.5.2.1.13 | ScalarproductAlarmCount | read-only | current | Number of alarms currently tripped |
| 1.3.6.1.4.1.21239.5.2.1.14 | ScalarproductWarnCount | read-only | current | Number of warnings currently tripped |
| 1.3.6.1.4.1.21239.5.2.1.15 | ScalarproductManufacturer | read-only | current | Product manufacturer |
| 1.3.6.1.4.1.21239.5.2.3 | Nodepdu | |||
| 1.3.6.1.4.1.21239.5.2.3.1 | TablepduMainTable | not-accessible | current | PDU general information |
| 1.3.6.1.4.1.21239.5.2.3.1.1 | RowpduMainEntry | not-accessible | current | Entry in the pduMainTable table: each entry contains an index and other sensor details |
| 1.3.6.1.4.1.21239.5.2.3.1.1.1 | ColumnpduMainIndex | not-accessible | current | Table entry index value |
| 1.3.6.1.4.1.21239.5.2.3.1.1.2 | ColumnpduMainSerial | read-only | current | Serial number |
| 1.3.6.1.4.1.21239.5.2.3.1.1.3 | ColumnpduMainName | read-only | current | PDU name (factory-assigned) |
| 1.3.6.1.4.1.21239.5.2.3.1.1.4 | ColumnpduMainLabel | read-write | current | PDU label (user-defined) |
| 1.3.6.1.4.1.21239.5.2.3.1.1.5 | ColumnpduMainAvail | read-only | current | Device availability: 0 = Unavailable 1 = Available 2 = Partially Unavailable |
| 1.3.6.1.4.1.21239.5.2.3.1.1.6 | ColumnpduMeterType | read-only | current | Current meter type: 0 = Wye 1 = Delta |
| 1.3.6.1.4.1.21239.5.2.3.1.1.7 | ColumnpduTotalName | read-only | current | Total name (factory-assigned) |
| 1.3.6.1.4.1.21239.5.2.3.1.1.8 | ColumnpduTotalLabel | read-write | current | Total label (user-defined) |
| 1.3.6.1.4.1.21239.5.2.3.1.1.9 | ColumnpduTotalRealPower | read-only | current | PDU total real power |
| 1.3.6.1.4.1.21239.5.2.3.1.1.10 | ColumnpduTotalApparentPower | read-only | current | PDU total apparent power |
| 1.3.6.1.4.1.21239.5.2.3.1.1.11 | ColumnpduTotalPowerFactor | read-only | current | PDU total power factor |
| 1.3.6.1.4.1.21239.5.2.3.1.1.12 | ColumnpduTotalEnergy | read-only | current | PDU total accumulated energy in watt-hours |
| 1.3.6.1.4.1.21239.5.2.3.2 | TablepduPhaseTable | not-accessible | current | PDU phases information |
| 1.3.6.1.4.1.21239.5.2.3.2.1 | RowpduPhaseEntry | not-accessible | current | Entry in the pduPhaseTable table: each entry contains an index and other sensor details |
| 1.3.6.1.4.1.21239.5.2.3.2.1.1 | ColumnpduPhaseIndex | not-accessible | current | Table entry index value |
| 1.3.6.1.4.1.21239.5.2.3.2.1.2 | ColumnpduPhaseName | read-only | current | PDU phase name (factory-assigned) |
| 1.3.6.1.4.1.21239.5.2.3.2.1.3 | ColumnpduPhaseLabel | read-write | current | PDU phase label (user-defined) |
| 1.3.6.1.4.1.21239.5.2.3.2.1.4 | ColumnpduPhaseVoltage | read-only | current | PDU phase voltage in tenths of a volt |
| 1.3.6.1.4.1.21239.5.2.3.2.1.8 | ColumnpduPhaseCurrent | read-only | current | PDU phase current reading in hundredths of an amp |
| 1.3.6.1.4.1.21239.5.2.3.2.1.12 | ColumnpduPhaseRealPower | read-only | current | Real power for phase in watts |
| 1.3.6.1.4.1.21239.5.2.3.2.1.13 | ColumnpduPhaseApparentPower | read-only | current | Apparent power for phase in volt-amps |
| 1.3.6.1.4.1.21239.5.2.3.2.1.14 | ColumnpduPhasePowerFactor | read-only | current | Power factor for phase |
| 1.3.6.1.4.1.21239.5.2.3.2.1.15 | ColumnpduPhaseEnergy | read-only | current | Accumulated energy for phase in watt-hours |
| 1.3.6.1.4.1.21239.5.2.3.2.1.17 | ColumnpduPhaseBalance | read-only | current | Phase balance as percent |
| 1.3.6.1.4.1.21239.5.2.3.2.1.19 | ColumnpduPhaseCurrentCrestFactor | read-only | current | Current crest factor for phase, in hundredths |
| 1.3.6.1.4.1.21239.5.2.3.2.1.20 | ColumnpduPhaseResCurrentDetected | read-only | current | Tells if residual current was detected. In normal operation, the value will be false(2). |
| 1.3.6.1.4.1.21239.5.2.3.3 | TablepduBreakerTable | not-accessible | current | PDU breaker information |
| 1.3.6.1.4.1.21239.5.2.3.3.1 | RowpduBreakerEntry | not-accessible | current | Entry in the pduBreakerTable table: each entry contains an index and other sensor details |
| 1.3.6.1.4.1.21239.5.2.3.3.1.1 | ColumnpduBreakerIndex | not-accessible | current | Table entry index value |
| 1.3.6.1.4.1.21239.5.2.3.3.1.2 | ColumnpduBreakerName | read-only | current | PDU breaker name (factory-assigned) |
| 1.3.6.1.4.1.21239.5.2.3.3.1.3 | ColumnpduBreakerLabel | read-write | current | PDU breaker label (user-defined) |
| 1.3.6.1.4.1.21239.5.2.3.3.1.4 | ColumnpduBreakerCurrent | read-only | current | PDU breaker current reading in hundredths of an amp |
| 1.3.6.1.4.1.21239.5.2.3.3.1.8 | ColumnpduBreakerVoltage | read-only | current | PDU breaker voltage in tenths of a volt. This object may not exist on all platforms, due to hardware differences. |
| 1.3.6.1.4.1.21239.5.2.3.3.1.12 | ColumnpduBreakerRealPower | read-only | current | Real power for breaker in watts. This object may not exist on all platforms, due to hardware differences. |
| 1.3.6.1.4.1.21239.5.2.3.3.1.13 | ColumnpduBreakerApparentPower | read-only | current | Apparent power for breaker in volt-amps. This object may not exist on all platforms, due to hardware differences. |
| 1.3.6.1.4.1.21239.5.2.3.3.1.14 | ColumnpduBreakerPowerFactor | read-only | current | Power factor for breaker. This object may not exist on all platforms, due to hardware differences. |
| 1.3.6.1.4.1.21239.5.2.3.3.1.15 | ColumnpduBreakerEnergy | read-only | current | Accumulated energy for breaker in watt-hours. This object may not exist on all platforms, due to hardware differences. |
| 1.3.6.1.4.1.21239.5.2.3.3.1.20 | ColumnpduBreakerResCurrentDetected | read-only | current | Tells if residual current was detected. In normal operation, the value will be false(2). |
| 1.3.6.1.4.1.21239.5.2.3.3.1.21 | ColumnpduBreakerLossOfLoadDetected | read-only | current | Tells if a loss of load was detected. In normal operation, the value will be false(2). |
| 1.3.6.1.4.1.21239.5.2.3.4 | TablepduLineTable | not-accessible | current | PDU line current information |
| 1.3.6.1.4.1.21239.5.2.3.4.1 | RowpduLineEntry | not-accessible | current | Entry in the pduLineTable table: each entry contains an index and other sensor details |
| 1.3.6.1.4.1.21239.5.2.3.4.1.1 | ColumnpduLineIndex | not-accessible | current | Table entry index value |
| 1.3.6.1.4.1.21239.5.2.3.4.1.2 | ColumnpduLineName | read-only | current | PDU line name (factory-assigned) |
| 1.3.6.1.4.1.21239.5.2.3.4.1.3 | ColumnpduLineLabel | read-write | current | PDU line label (user-defined) |
| 1.3.6.1.4.1.21239.5.2.3.4.1.4 | ColumnpduLineCurrent | read-only | current | PDU line current reading in hundredths of an amp |
| 1.3.6.1.4.1.21239.5.2.3.5 | TablepduOutletSwitchTable | not-accessible | current | Data, config and control for outlets with switching |
| 1.3.6.1.4.1.21239.5.2.3.5.1 | RowpduOutletSwitchEntry | not-accessible | current | Entry in the pduOutletSwitchTable table: each entry contains an index and other sensor details |
| 1.3.6.1.4.1.21239.5.2.3.5.1.1 | ColumnpduOutletSwitchIndex | not-accessible | current | Table entry index value |
| 1.3.6.1.4.1.21239.5.2.3.5.1.2 | ColumnpduOutletSwitchName | read-only | current | PDU outlet name (factory-assigned) |
| 1.3.6.1.4.1.21239.5.2.3.5.1.3 | ColumnpduOutletSwitchLabel | read-write | current | PDU outlet label (user-defined) |
| 1.3.6.1.4.1.21239.5.2.3.5.1.4 | ColumnpduOutletSwitchState | read-only | current | Switch state of the outlet: 1 = Outlet is on 2 = Outlet is off 3 = Outlet is on, but will turn off after a delay 4 = Outlet is off, but will turn on after a de… |
| 1.3.6.1.4.1.21239.5.2.3.5.1.5 | ColumnpduOutletSwitchRelayFailure | read-only | current | Tells if the outlet relay has failed. In normal operation, the value will be false(2). |
| 1.3.6.1.4.1.21239.5.2.3.5.1.6 | ColumnpduOutletSwitchControl | read-write | current | Used for manual control of the outlet. If the outlet is in manual mode, this field can be set to one of the following values: 1 = Cancel pending operation 2 = … |
| 1.3.6.1.4.1.21239.5.2.3.5.1.7 | ColumnpduOutletSwitchTimeToAction | read-only | current | Seconds until an outlet state change. The value of pduOutletSwitchState tells what state the outlet will be set, after the delay. |
| 1.3.6.1.4.1.21239.5.2.3.5.1.8 | ColumnpduOutletSwitchOnDelay | read-write | current | Seconds to wait before powering on the outlet, during onAfterDelay(3) operation. Changing this value has no effect on pending actions. |
| 1.3.6.1.4.1.21239.5.2.3.5.1.9 | ColumnpduOutletSwitchOffDelay | read-write | current | Seconds to wait before powering off the outlet, during offAfterDelay(5) operation. Changing this value has no effect on pending actions. |
| 1.3.6.1.4.1.21239.5.2.3.5.1.10 | ColumnpduOutletSwitchRebootDelay | read-write | current | Seconds to wait before powering off the outlet, during rebootAfterDelay(7) operation. Changing this value has no effect on pending actions. See pduOutletSwitch… |
| 1.3.6.1.4.1.21239.5.2.3.5.1.11 | ColumnpduOutletSwitchRebootHoldDelay | read-write | current | Seconds to hold the outlet off, before powering on the outlet, during rebootAfterDelay(7) operation. Changing this value has no effect on pending actions. See … |
| 1.3.6.1.4.1.21239.5.2.3.5.1.12 | ColumnpduOutletSwitchPoaAction | read-write | current | The outlet is set to this state during power-up. The action can be have one the following values: 1 = Outlet will be turned on 2 = Outlet will stay off 3 = Out… |
| 1.3.6.1.4.1.21239.5.2.3.5.1.13 | ColumnpduOutletSwitchPoaDelay | read-write | current | Seconds to wait before setting the outlet to the pduOutletSwitchPoaAction state. The delay starts at power-up. |
| 1.3.6.1.4.1.21239.5.2.3.6 | TablepduOutletMeterTable | not-accessible | current | Metering data for outlets that support this feature |
| 1.3.6.1.4.1.21239.5.2.3.6.1 | RowpduOutletMeterEntry | not-accessible | current | Entry in the pduOutletMeterTable table: each entry contains an index and other sensor details |
| 1.3.6.1.4.1.21239.5.2.3.6.1.1 | ColumnpduOutletMeterIndex | not-accessible | current | Table entry index value |
| 1.3.6.1.4.1.21239.5.2.3.6.1.2 | ColumnpduOutletMeterName | read-only | current | PDU outlet name (factory-assigned) |
| 1.3.6.1.4.1.21239.5.2.3.6.1.3 | ColumnpduOutletMeterLabel | read-write | current | PDU outlet label (user-defined) |
| 1.3.6.1.4.1.21239.5.2.3.6.1.4 | ColumnpduOutletMeterVoltage | read-only | current | PDU outlet voltage in tenths of a volt |
| 1.3.6.1.4.1.21239.5.2.3.6.1.8 | ColumnpduOutletMeterCurrent | read-only | current | PDU outlet current reading in hundredths of an amp |
| 1.3.6.1.4.1.21239.5.2.3.6.1.12 | ColumnpduOutletMeterRealPower | read-only | current | Real power for outlet in watts |
| 1.3.6.1.4.1.21239.5.2.3.6.1.13 | ColumnpduOutletMeterApparentPower | read-only | current | Apparent power for outlet in volt-amps |
| 1.3.6.1.4.1.21239.5.2.3.6.1.14 | ColumnpduOutletMeterPowerFactor | read-only | current | Power factor for outlet |
| 1.3.6.1.4.1.21239.5.2.3.6.1.15 | ColumnpduOutletMeterEnergy | read-only | current | Accumulated energy for outlet in watt-hours |
| 1.3.6.1.4.1.21239.5.2.3.6.1.16 | ColumnpduOutletMeterReset | read-write | current | Used to reset energy. If read, the value is none(8). It can be set to resetEnergy(1), which sets outlet energy to 0 |
| 1.3.6.1.4.1.21239.5.2.3.6.1.19 | ColumnpduOutletCurrentCrestFactor | read-only | current | Current crest factor for outlet, in hundredths |
| 1.3.6.1.4.1.21239.5.2.3.7 | TablepduResidualCurrentTable | not-accessible | current | Residual current data for PDUs that support this feature |
| 1.3.6.1.4.1.21239.5.2.3.7.1 | RowpduResidualCurrentEntry | not-accessible | current | Entry in the pduResidualCurrentTable table: each entry contains an index and other sensor details |
| 1.3.6.1.4.1.21239.5.2.3.7.1.1 | ColumnpduResidualCurrentIndex | not-accessible | current | Table entry index value |
| 1.3.6.1.4.1.21239.5.2.3.7.1.2 | ColumnpduResidualCurrentName | read-only | current | PDU residual current name (factory-assigned) |
| 1.3.6.1.4.1.21239.5.2.3.7.1.3 | ColumnpduResidualCurrentLabel | read-only | current | PDU residual current label |
| 1.3.6.1.4.1.21239.5.2.3.7.1.4 | ColumnpduResidualCurrentAggregate | read-only | current | PDU residual current aggregate value in milliamps |
| 1.3.6.1.4.1.21239.5.2.3.7.1.5 | ColumnpduResidualCurrentDc | read-only | current | PDU residual current DC value in milliamps |
| 1.3.6.1.4.1.21239.5.2.4 | TabletempSensorTable | not-accessible | current | Remote Temperature (RT) sensor |
| 1.3.6.1.4.1.21239.5.2.4.1 | RowtempSensorEntry | not-accessible | current | Entry in the tempSensorTable table: each entry contains an index and other sensor details |
| 1.3.6.1.4.1.21239.5.2.4.1.1 | ColumntempSensorIndex | not-accessible | current | Table entry index value |
| 1.3.6.1.4.1.21239.5.2.4.1.2 | ColumntempSensorSerial | read-only | current | Serial number |
| 1.3.6.1.4.1.21239.5.2.4.1.3 | ColumntempSensorLabel | read-write | current | User-defined label |
| 1.3.6.1.4.1.21239.5.2.4.1.4 | ColumntempSensorAvail | read-only | current | Device availability: 0 = Unavailable 1 = Available 2 = Partially Unavailable |
| 1.3.6.1.4.1.21239.5.2.4.1.5 | ColumntempSensorTemp | read-only | current | Temperature in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. |
| 1.3.6.1.4.1.21239.5.2.5 | TableairFlowSensorTable | not-accessible | current | Remote Airflow, Humidity, Temperature and Dewpoint (AFHT3) Sensor |
| 1.3.6.1.4.1.21239.5.2.5.1 | RowairFlowSensorEntry | not-accessible | current | Entry in the airFlowSensorTable table: each entry contains an index and other sensor details |
| 1.3.6.1.4.1.21239.5.2.5.1.1 | ColumnairFlowSensorIndex | not-accessible | current | Table entry index value |
| 1.3.6.1.4.1.21239.5.2.5.1.2 | ColumnairFlowSensorSerial | read-only | current | Serial number |
| 1.3.6.1.4.1.21239.5.2.5.1.3 | ColumnairFlowSensorLabel | read-write | current | User-defined label |
| 1.3.6.1.4.1.21239.5.2.5.1.4 | ColumnairFlowSensorAvail | read-only | current | Device availability: 0 = Unavailable 1 = Available 2 = Partially Unavailable |
| 1.3.6.1.4.1.21239.5.2.5.1.5 | ColumnairFlowSensorTemp | read-only | current | Temperature reading in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. |
| 1.3.6.1.4.1.21239.5.2.5.1.6 | ColumnairFlowSensorFlow | read-only | current | Airflow reading. Still air will be less than 20, while rushing air will be around 100. |
| 1.3.6.1.4.1.21239.5.2.5.1.7 | ColumnairFlowSensorHumidity | read-only | current | Humidity reading |
| 1.3.6.1.4.1.21239.5.2.5.1.8 | ColumnairFlowSensorDewPoint | read-only | current | Dewpoint reading in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. |
| 1.3.6.1.4.1.21239.5.2.8 | Tablet3hdSensorTable | not-accessible | current | Remote Temperature x 3, Humidity and Dewpoint Sensor |
| 1.3.6.1.4.1.21239.5.2.8.1 | Rowt3hdSensorEntry | not-accessible | current | Entry in the t3hdSensorTable table: each entry contains an index and other sensor details |
| 1.3.6.1.4.1.21239.5.2.8.1.1 | Columnt3hdSensorIndex | not-accessible | current | Table entry index value |
| 1.3.6.1.4.1.21239.5.2.8.1.2 | Columnt3hdSensorSerial | read-only | current | Serial number |
| 1.3.6.1.4.1.21239.5.2.8.1.3 | Columnt3hdSensorLabel | read-write | current | User-defined label |
| 1.3.6.1.4.1.21239.5.2.8.1.4 | Columnt3hdSensorAvail | read-only | current | Device availability: 0 = Unavailable 1 = Available 2 = Partially Unavailable |
| 1.3.6.1.4.1.21239.5.2.8.1.5 | Columnt3hdSensorIntLabel | read-write | current | Internal label (user-defined) |
| 1.3.6.1.4.1.21239.5.2.8.1.6 | Columnt3hdSensorIntTemp | read-only | current | Internal temperature in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. |
| 1.3.6.1.4.1.21239.5.2.8.1.7 | Columnt3hdSensorIntHumidity | read-only | current | Internal humidity |
| 1.3.6.1.4.1.21239.5.2.8.1.8 | Columnt3hdSensorIntDewPoint | read-only | current | Internal dewpoint in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. |
| 1.3.6.1.4.1.21239.5.2.8.1.9 | Columnt3hdSensorExtAAvail | read-only | current | External A status: 0 = Unavailable 1 = Available |
| 1.3.6.1.4.1.21239.5.2.8.1.10 | Columnt3hdSensorExtALabel | read-write | current | External A label (user-defined) |
| 1.3.6.1.4.1.21239.5.2.8.1.11 | Columnt3hdSensorExtATemp | read-only | current | External A temperature in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. |
| 1.3.6.1.4.1.21239.5.2.8.1.12 | Columnt3hdSensorExtBAvail | read-only | current | External B status: 0 = Unavailable 1 = Available |
| 1.3.6.1.4.1.21239.5.2.8.1.13 | Columnt3hdSensorExtBLabel | read-write | current | External B label (user-defined) |
| 1.3.6.1.4.1.21239.5.2.8.1.14 | Columnt3hdSensorExtBTemp | read-only | current | External B temperature in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. |
| 1.3.6.1.4.1.21239.5.2.9 | TablethdSensorTable | not-accessible | current | Remote Temperature, Humidity, and Dewpoint (THD) Sensor |
| 1.3.6.1.4.1.21239.5.2.9.1 | RowthdSensorEntry | not-accessible | current | Entry in the thdSensorTable table: each entry contains an index and other sensor details |
| 1.3.6.1.4.1.21239.5.2.9.1.1 | ColumnthdSensorIndex | not-accessible | current | Table entry index value |
| 1.3.6.1.4.1.21239.5.2.9.1.2 | ColumnthdSensorSerial | read-only | current | Serial number |
| 1.3.6.1.4.1.21239.5.2.9.1.3 | ColumnthdSensorLabel | read-write | current | User-defined label |
| 1.3.6.1.4.1.21239.5.2.9.1.4 | ColumnthdSensorAvail | read-only | current | Device availability: 0 = Unavailable 1 = Available 2 = Partially Unavailable |
| 1.3.6.1.4.1.21239.5.2.9.1.5 | ColumnthdSensorTemp | read-only | current | Temperature value in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. |
| 1.3.6.1.4.1.21239.5.2.9.1.6 | ColumnthdSensorHumidity | read-only | current | Humidity value |
| 1.3.6.1.4.1.21239.5.2.9.1.7 | ColumnthdSensorDewPoint | read-only | current | Dewpoint value in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. |
| 1.3.6.1.4.1.21239.5.2.11 | Tablea2dSensorTable | not-accessible | current | Analog measurement (A2D) sensor (voltage, current, or dry-contact) |
| 1.3.6.1.4.1.21239.5.2.11.1 | Rowa2dSensorEntry | not-accessible | current | Entry in the a2dSensorTable table: each entry contains an index and other sensor details |
| 1.3.6.1.4.1.21239.5.2.11.1.1 | Columna2dSensorIndex | not-accessible | current | Table entry index value |
| 1.3.6.1.4.1.21239.5.2.11.1.2 | Columna2dSensorSerial | read-only | current | Serial number |
| 1.3.6.1.4.1.21239.5.2.11.1.3 | Columna2dSensorLabel | read-write | current | User-defined label |
| 1.3.6.1.4.1.21239.5.2.11.1.4 | Columna2dSensorAvail | read-only | current | Device availability: 0 = Unavailable 1 = Available 2 = Partially Unavailable |
| 1.3.6.1.4.1.21239.5.2.11.1.5 | Columna2dSensorValue | read-only | current | Analog measurement value, within either a user-defined or preset range, depending on a2dSensorMode. |
| 1.3.6.1.4.1.21239.5.2.11.1.6 | Columna2dSensorDisplayValue | read-only | current | For current/voltage modes, the analog value is given as a string. In binary modes, the value is either a2dSensorLowLabel or a2dSensorHighLabel, based on a2dSen… |
| 1.3.6.1.4.1.21239.5.2.11.1.7 | Columna2dSensorMode | read-write | current | Binary modes have two states represented by the values 0 (low) or 1 (high). These correspond to a2dSensorLowLabel and a2dSensorHighLabel. Current and voltage m… |
| 1.3.6.1.4.1.21239.5.2.11.1.8 | Columna2dSensorUnits | read-write | current | The units for the analog value. If a2dSensorMode is customVoltage(9) or customCurrent(11), then this field has a user-defined value. Otherwise, the value is fi… |
| 1.3.6.1.4.1.21239.5.2.11.1.9 | Columna2dSensorMin | read-write | current | Minimum analog value, given as an integer. The analog measurement is scaled to the range a2dSensorMin to a2dSensorMax. If a2dSensorMode is customVoltage(9) or … |
| 1.3.6.1.4.1.21239.5.2.11.1.10 | Columna2dSensorMax | read-write | current | Maximum analog value, given as an integer. The analog measurement is scaled to the range a2dSensorMin to a2dSensorMax. If a2dSensorMode is customVoltage(9) or … |
| 1.3.6.1.4.1.21239.5.2.11.1.11 | Columna2dSensorLowLabel | read-write | current | Label for 0 (low) binary value. This field is only applicable if a2dSensorMode is one of the binary modes. If a2dSensorMode is customBinary(10), then this fiel… |
| 1.3.6.1.4.1.21239.5.2.11.1.12 | Columna2dSensorHighLabel | read-write | current | Label for 1 (high) binary value. The field is only applicable if a2dSensorMode is one of the binary modes. If a2dSensorMode is customBinary(10), then this fiel… |
| 1.3.6.1.4.1.21239.5.2.11.1.13 | Columna2dSensorAnalogLabel | read-write | current | Label for the analog measurement |
| 1.3.6.1.4.1.21239.5.2.12 | TablehumiditySensorTable | not-accessible | current | Remote humidity sensor |
| 1.3.6.1.4.1.21239.5.2.12.1 | RowhumiditySensorEntry | not-accessible | current | Entry in the humiditySensorTable table: each entry contains an index and other sensor details |
| 1.3.6.1.4.1.21239.5.2.12.1.1 | ColumnhumiditySensorIndex | not-accessible | current | Table entry index value |
| 1.3.6.1.4.1.21239.5.2.12.1.2 | ColumnhumiditySensorSerial | read-only | current | Serial number |
| 1.3.6.1.4.1.21239.5.2.12.1.3 | ColumnhumiditySensorLabel | read-write | current | User-defined label |
| 1.3.6.1.4.1.21239.5.2.12.1.4 | ColumnhumiditySensorAvail | read-only | current | Device availability: 0 = Unavailable 1 = Available 2 = Partially Unavailable |
| 1.3.6.1.4.1.21239.5.2.12.1.5 | ColumnhumiditySensorValue | read-only | current | Humidity value |
| 1.3.6.1.4.1.21239.5.2.13 | Tablesn2dSensorTable | not-accessible | current | 2 Door Switch Sensor (SN-2D) |
| 1.3.6.1.4.1.21239.5.2.13.1 | Rowsn2dSensorEntry | not-accessible | current | Entry in the sn2dSensorTable table: each entry contains an index and other sensor details |
| 1.3.6.1.4.1.21239.5.2.13.1.1 | Columnsn2dSensorIndex | not-accessible | current | Table entry index value |
| 1.3.6.1.4.1.21239.5.2.13.1.2 | Columnsn2dSensorSerial | read-only | current | Serial number |
| 1.3.6.1.4.1.21239.5.2.13.1.3 | Columnsn2dSensorLabel | read-write | current | User-defined label |
| 1.3.6.1.4.1.21239.5.2.13.1.4 | Columnsn2dSensorAvail | read-only | current | Device availability: 0 = Unavailable 1 = Available 2 = Partially Unavailable |
| 1.3.6.1.4.1.21239.5.2.13.1.5 | Columnsn2dSensorDoor1Label | read-write | current | Door switch 1 label |
| 1.3.6.1.4.1.21239.5.2.13.1.6 | Columnsn2dSensorDoor1State | read-only | current | Door switch 1 state: 1 = open 2 = closed |
| 1.3.6.1.4.1.21239.5.2.13.1.7 | Columnsn2dSensorDoor1DisplayState | read-only | current | Door switch 1 state given as a string |
| 1.3.6.1.4.1.21239.5.2.13.1.8 | Columnsn2dSensorDoor2Label | read-write | current | Door switch 2 label |
| 1.3.6.1.4.1.21239.5.2.13.1.9 | Columnsn2dSensorDoor2State | read-only | current | Door switch 2 state: 1 = open 2 = closed |
| 1.3.6.1.4.1.21239.5.2.13.1.10 | Columnsn2dSensorDoor2DisplayState | read-only | current | Door switch 2 state given as a string |
| 1.3.6.1.4.1.21239.5.2.30 | Nodecooling | |||
| 1.3.6.1.4.1.21239.5.2.30.1 | Nodevrc | |||
| 1.3.6.1.4.1.21239.5.2.30.1.1 | TablevrcMainTable | not-accessible | current | Table that contains general VRC information |
| 1.3.6.1.4.1.21239.5.2.30.1.1.1 | RowvrcMainEntry | not-accessible | current | Entry in the vrcMainTable: each entry represents a VRC device |
| 1.3.6.1.4.1.21239.5.2.30.1.1.1.1 | ColumnvrcMainIndex | not-accessible | current | Unique id for each entry in the table |
| 1.3.6.1.4.1.21239.5.2.30.1.1.1.2 | ColumnvrcMainSerial | read-only | current | Serial number |
| 1.3.6.1.4.1.21239.5.2.30.1.1.1.3 | ColumnvrcMainName | read-only | current | VRC name (factory-assigned) |
| 1.3.6.1.4.1.21239.5.2.30.1.1.1.4 | ColumnvrcMainLabel | read-write | current | VRC label (user-defined) |
| 1.3.6.1.4.1.21239.5.2.30.1.1.1.5 | ColumnvrcMainAvail | read-only | current | Device availability: 0 = Unavailable 1 = Available 2 = Partially Unavailable |
| 1.3.6.1.4.1.21239.5.2.30.1.2 | TablevrcMainPtTable | not-accessible | current | Table that contains general VRC status |
| 1.3.6.1.4.1.21239.5.2.30.1.2.1 | RowvrcMainPtEntry | not-accessible | current | Entry in the vrcMainPtTable: each entry contains status data for a VRC device |
| 1.3.6.1.4.1.21239.5.2.30.1.2.1.1 | ColumnvrcMainPtIndex | not-accessible | current | Unique id for each entry in the table |
| 1.3.6.1.4.1.21239.5.2.30.1.2.1.2 | ColumnvrcMainPtRunState | read-only | current | VRC run state: 1 = on 2 = off |
| 1.3.6.1.4.1.21239.5.2.30.1.2.1.3 | ColumnvrcMainPtEevOpened | read-only | current | Eev opened value (percent) |
| 1.3.6.1.4.1.21239.5.2.30.1.2.1.4 | ColumnvrcMainPtAlarmNumbers | read-only | current | Alarm numbers value |
| 1.3.6.1.4.1.21239.5.2.30.1.2.1.5 | ColumnvrcMainPtHistoryAlarmNumbers | read-only | current | History alarm numbers value |
| 1.3.6.1.4.1.21239.5.2.30.1.2.1.6 | ColumnvrcMainPtHpAbnRecordCnt | read-only | current | Hp Abnormal record count |
| 1.3.6.1.4.1.21239.5.2.30.1.2.1.7 | ColumnvrcMainPtMonitorBaudrate | read-only | current | Monitor baud rate: 1 = error 2 = 1200 3 = 2400 4 = 4800 5 = 9600 6 = 19200 |
| 1.3.6.1.4.1.21239.5.2.30.1.2.1.8 | ColumnvrcMainPtMonitorAddress | read-only | current | Monitor address |
| 1.3.6.1.4.1.21239.5.2.30.1.2.1.9 | ColumnvrcMainPtLp | read-only | current | Lp status |
| 1.3.6.1.4.1.21239.5.2.30.1.2.1.10 | ColumnvrcMainPtFilterMaintRemind | read-only | current | Filter maintenance reminder status |
| 1.3.6.1.4.1.21239.5.2.30.1.2.1.11 | ColumnvrcMainPtCoolingFlag | read-only | current | Cooling flag |
| 1.3.6.1.4.1.21239.5.2.30.1.2.1.12 | ColumnvrcMainPtFirstOnFlag | read-only | current | First on flag |
| 1.3.6.1.4.1.21239.5.2.30.1.2.1.13 | ColumnvrcMainPtNewAlarmFlag | read-only | current | New alarm flag |
| 1.3.6.1.4.1.21239.5.2.30.1.2.1.14 | ColumnvrcMainPtComAlarmOutState | read-only | current | Common alarm output state |
| 1.3.6.1.4.1.21239.5.2.30.1.2.1.15 | ColumnvrcMainPtHighWaterInput | read-only | current | High water input |
| 1.3.6.1.4.1.21239.5.2.30.1.2.1.16 | ColumnvrcMainPtHighWaterAlarm | read-only | current | High water alarm status |
| 1.3.6.1.4.1.21239.5.2.30.1.2.1.17 | ColumnvrcMainPtWaterUnderFloorAlarm | read-only | current | Water under floor alarm status |
| 1.3.6.1.4.1.21239.5.2.30.1.2.1.18 | ColumnvrcMainPtSwShutDownStatus | read-only | current | Software shutdown status |
| 1.3.6.1.4.1.21239.5.2.30.1.2.1.19 | ColumnvrcMainPtRemoteShutdown | read-only | current | Remote shutdown status |
| 1.3.6.1.4.1.21239.5.2.30.1.2.1.20 | ColumnvrcMainPtRemoteShutDownFlag | read-only | current | Remote shutdown flag |
| 1.3.6.1.4.1.21239.5.2.30.1.2.1.21 | ColumnvrcMainPtRemoteShutDownAlarm | read-only | current | Remote shutdown alarm status |
| 1.3.6.1.4.1.21239.5.2.30.1.2.1.22 | ColumnvrcMainPtHmiShutDownFlag | read-only | current | Hmi shutdown flag |
| 1.3.6.1.4.1.21239.5.2.30.1.2.1.23 | ColumnvrcMainPtLpAlarm | read-only | current | Low pressure alarm status |
| 1.3.6.1.4.1.21239.5.2.30.1.2.1.24 | ColumnvrcMainPtHpAlarm | read-only | current | High pressure alarm status |
| 1.3.6.1.4.1.21239.5.2.30.1.2.1.25 | ColumnvrcMainPtLpFreqAlarm | read-only | current | Low pressure frequently alarm status |
| 1.3.6.1.4.1.21239.5.2.30.1.2.1.26 | ColumnvrcMainPtHpFreqAlarm | read-only | current | High pressure frequently alarm status |
| 1.3.6.1.4.1.21239.5.2.30.1.2.1.27 | ColumnvrcMainPtLpSensorFailAlarm | read-only | current | Low pressure sensor failure alarm status |
| 1.3.6.1.4.1.21239.5.2.30.1.2.1.28 | ColumnvrcMainPtHpSensorFailAlarm | read-only | current | High pressure sensor failure alarm status |
| 1.3.6.1.4.1.21239.5.2.30.1.2.1.29 | ColumnvrcMainPtEevCommFailAlarm | read-only | current | Eev communication failure alarm status |
| 1.3.6.1.4.1.21239.5.2.30.1.3 | TablevrcMainCfgTable | not-accessible | current | Table that contains general VRC configuration |
| 1.3.6.1.4.1.21239.5.2.30.1.3.1 | RowvrcMainCfgEntry | not-accessible | current | Entry in the vrcMainCfgTable: each entry contains general config fields for a VRC device |
| 1.3.6.1.4.1.21239.5.2.30.1.3.1.1 | ColumnvrcMainCfgIndex | not-accessible | current | Unique id for each entry in the table |
| 1.3.6.1.4.1.21239.5.2.30.1.3.1.2 | ColumnvrcMainCfgModelSelect | read-write | current | Model Selection: 1 = TMM-Local 220V 50/60HZ 2 = TMM-Global 208/230V 50/60HZ 3 = TMM-Global 120V 50/60HZ 4 = SC 220V 50/60HZ 5 = 0U 220V 50/60HZ 6 = SS 208/230V… |
| 1.3.6.1.4.1.21239.5.2.30.1.3.1.3 | ColumnvrcMainCfgSystemTimeYear | read-write | current | System time - year |
| 1.3.6.1.4.1.21239.5.2.30.1.3.1.4 | ColumnvrcMainCfgSystemTimeMonth | read-write | current | System time - month |
| 1.3.6.1.4.1.21239.5.2.30.1.3.1.5 | ColumnvrcMainCfgSystemTimeDay | read-write | current | System time - day |
| 1.3.6.1.4.1.21239.5.2.30.1.3.1.6 | ColumnvrcMainCfgSystemTimeHour | read-write | current | System time - hour |
| 1.3.6.1.4.1.21239.5.2.30.1.3.1.7 | ColumnvrcMainCfgSystemTimeMin | read-write | current | System time - minutes |
| 1.3.6.1.4.1.21239.5.2.30.1.3.1.8 | ColumnvrcMainCfgSystemTimeSec | read-write | current | System time - seconds |
| 1.3.6.1.4.1.21239.5.2.30.1.3.1.9 | ColumnvrcMainCfgEevShtSettingMin | read-write | current | Min Eev sht in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The settable range is determined by the current temperature units. … |
| 1.3.6.1.4.1.21239.5.2.30.1.3.1.10 | ColumnvrcMainCfgEevShtSettingMax | read-write | current | Max Eev sht in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The settable range is determined by the current temperature units. … |
| 1.3.6.1.4.1.21239.5.2.30.1.3.1.11 | ColumnvrcMainCfgEevValveCloseSht | read-write | current | Eev valve close sht in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The settable range is determined by the current temperature… |
| 1.3.6.1.4.1.21239.5.2.30.1.3.1.12 | ColumnvrcMainCfgEevMopPressSetting | read-write | current | Eev mop pressure setting in tenths of a bar. |
| 1.3.6.1.4.1.21239.5.2.30.1.3.1.13 | ColumnvrcMainCfgLpdt | read-write | current | Low pressure dt in seconds |
| 1.3.6.1.4.1.21239.5.2.30.1.3.1.14 | ColumnvrcMainCfgDeadBand | read-write | current | Dead band in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The settable range is determined by the current temperature units. Ce… |
| 1.3.6.1.4.1.21239.5.2.30.1.3.1.15 | ColumnvrcMainCfgOnOffSwitch | read-write | current | On-off switch |
| 1.3.6.1.4.1.21239.5.2.30.1.3.1.16 | ColumnvrcMainCfgVacuumState | read-write | current | Vacuum state |
| 1.3.6.1.4.1.21239.5.2.30.1.3.1.17 | ColumnvrcMainCfgControlMode | read-write | current | Control mode: 1 = supply 2 = return |
| 1.3.6.1.4.1.21239.5.2.30.1.3.1.18 | ColumnvrcMainCfgManualRunEnable | read-write | current | Manual run enable |
| 1.3.6.1.4.1.21239.5.2.30.1.3.1.19 | ColumnvrcMainCfgRemShutdownInput | read-write | current | Remote shutdown input |
| 1.3.6.1.4.1.21239.5.2.30.1.3.1.20 | ColumnvrcMainCfgMonitorShutDownFlag | read-write | current | Monitor shutdown flag |
| 1.3.6.1.4.1.21239.5.2.30.1.3.1.21 | ColumnvrcMainCfgFirstOnPassword | read-write | current | First on password value |
| 1.3.6.1.4.1.21239.5.2.30.1.3.1.22 | ColumnvrcMainCfgFilterMaintSetting | read-write | current | Filter maintenance setting |
| 1.3.6.1.4.1.21239.5.2.30.1.3.1.23 | ColumnvrcMainCfgFilterMaintRemindTime | read-write | current | Time between filter maintenance reminders in days |
| 1.3.6.1.4.1.21239.5.2.30.1.3.1.24 | ColumnvrcMainCfgFilterMaintRemindCtrl | read-write | current | Filter maintenance reminder: 1 = close 2 = suspend 3 = open |
| 1.3.6.1.4.1.21239.5.2.30.1.3.1.25 | ColumnvrcMainCfgCommonAlarmOutputDir | read-write | current | Common alarm output direction |
| 1.3.6.1.4.1.21239.5.2.30.1.3.1.26 | ColumnvrcMainCfgHpAbnAlarmSetting | read-write | current | Abnormal high pressure alarm value in tenths of a bar |
| 1.3.6.1.4.1.21239.5.2.30.1.3.1.27 | ColumnvrcMainCfgLpAlarmCtrl | read-write | current | Low pressure alarm control: 2 = suspend 3 = open |
| 1.3.6.1.4.1.21239.5.2.30.1.3.1.28 | ColumnvrcMainCfgHpAlarmCtrl | read-write | current | High pressure alarm control: 2 = suspend 3 = open |
| 1.3.6.1.4.1.21239.5.2.30.1.3.1.29 | ColumnvrcMainCfgLpFreqAlarmCtrl | read-write | current | Low pressure frequently alarm control: 2 = suspend 3 = open |
| 1.3.6.1.4.1.21239.5.2.30.1.3.1.30 | ColumnvrcMainCfgHpFreqAlarmCtrl | read-write | current | High pressure frequently alarm control: 2 = suspend 3 = open |
| 1.3.6.1.4.1.21239.5.2.30.1.3.1.31 | ColumnvrcMainCfgLpSensorFailAlarmCtrl | read-write | current | Low pressure sensor failure alarm control: 2 = suspend 3 = open |
| 1.3.6.1.4.1.21239.5.2.30.1.3.1.32 | ColumnvrcMainCfgHpSensorFailAlarmCtrl | read-write | current | High pressure sensor failure alarm control: 2 = suspend 3 = open |
| 1.3.6.1.4.1.21239.5.2.30.1.3.1.33 | ColumnvrcMainCfgHighWaterAlarmCtrl | read-write | current | High water alarm control: 1 = close 2 = suspend 3 = open |
| 1.3.6.1.4.1.21239.5.2.30.1.3.1.34 | ColumnvrcMainCfgRemShutdownAlarmCtrl | read-write | current | Remote shutdown alarm control: 2 = suspend 3 = open |
| 1.3.6.1.4.1.21239.5.2.30.1.3.1.35 | ColumnvrcMainCfgEevCommFailAlarmCtrl | read-write | current | Eev communication failure alarm: 2 = suspend 3 = open |
| 1.3.6.1.4.1.21239.5.2.30.1.4 | TablevrcOutFanPtTable | not-accessible | current | Table that contains VRC out-fan status |
| 1.3.6.1.4.1.21239.5.2.30.1.4.1 | RowvrcOutFanPtEntry | not-accessible | current | Entry in the vrcOutFanPtTable: each entry represents data for a VRC out-fan |
| 1.3.6.1.4.1.21239.5.2.30.1.4.1.1 | ColumnvrcOutFanPtIndex | not-accessible | current | Unique id for each entry in the table |
| 1.3.6.1.4.1.21239.5.2.30.1.4.1.2 | ColumnvrcOutFanPtName | read-only | current | Out-fan name (factory-assigned) |
| 1.3.6.1.4.1.21239.5.2.30.1.4.1.3 | ColumnvrcOutFanPtSpeed | read-only | current | Fan speed (percent) |
| 1.3.6.1.4.1.21239.5.2.30.1.5 | TablevrcOutFanCfgTable | not-accessible | current | Table used for VRC out-fan configuration |
| 1.3.6.1.4.1.21239.5.2.30.1.5.1 | RowvrcOutFanCfgEntry | not-accessible | current | Entry in the vrcOutFanCfgTable: each entry contains config fields for a VRC out-fan |
| 1.3.6.1.4.1.21239.5.2.30.1.5.1.1 | ColumnvrcOutFanCfgIndex | not-accessible | current | Unique id for each entry in the table |
| 1.3.6.1.4.1.21239.5.2.30.1.5.1.2 | ColumnvrcOutFanCfgStartPress | read-write | current | Out-fan start pressure in tenths of a bar |
| 1.3.6.1.4.1.21239.5.2.30.1.5.1.3 | ColumnvrcOutFanCfgPressSetting | read-write | current | Out-fan pressure setting in tenths of a bar |
| 1.3.6.1.4.1.21239.5.2.30.1.5.1.4 | ColumnvrcOutFanCfgMinPowerVoltage | read-write | current | Min out-fan voltage (percent) |
| 1.3.6.1.4.1.21239.5.2.30.1.5.1.5 | ColumnvrcOutFanCfgMaxPowerVoltage | read-write | current | Max out-fan voltage (percent) |
| 1.3.6.1.4.1.21239.5.2.30.1.5.1.6 | ColumnvrcOutFanCfgSpeed | read-write | current | Out-fan speed (percent) |
| 1.3.6.1.4.1.21239.5.2.30.1.6 | TablevrcInFanPtTable | not-accessible | current | Table that contains VRC in-fan status |
| 1.3.6.1.4.1.21239.5.2.30.1.6.1 | RowvrcInFanPtEntry | not-accessible | current | Entry in the vrcInFanPtTable: each entry represents data for a VRC in- fan |
| 1.3.6.1.4.1.21239.5.2.30.1.6.1.1 | ColumnvrcInFanPtIndex | not-accessible | current | Unique id for each entry in the table |
| 1.3.6.1.4.1.21239.5.2.30.1.6.1.2 | ColumnvrcInFanPtName | read-only | current | In-fan name (factory-assigned) |
| 1.3.6.1.4.1.21239.5.2.30.1.6.1.3 | ColumnvrcInFanPtRunTimeHours | read-only | current | In-fan run time in hours |
| 1.3.6.1.4.1.21239.5.2.30.1.6.1.4 | ColumnvrcInFanPtStartStopCount | read-only | current | In-fan start/stop count |
| 1.3.6.1.4.1.21239.5.2.30.1.7 | TablevrcInFanCfgTable | not-accessible | current | Table used for VRC in-fan configuration |
| 1.3.6.1.4.1.21239.5.2.30.1.7.1 | RowvrcInFanCfgEntry | not-accessible | current | Entry in the vrcInFanCfgTable: each entry contains config fields for a VRC in-fan |
| 1.3.6.1.4.1.21239.5.2.30.1.7.1.1 | ColumnvrcInFanCfgIndex | not-accessible | current | Unique id for each entry in the table |
| 1.3.6.1.4.1.21239.5.2.30.1.7.1.2 | ColumnvrcInFanCfgOutputStatus | read-write | current | In-fan output status |
| 1.3.6.1.4.1.21239.5.2.30.1.7.1.3 | ColumnvrcInFanCfgLowSpeedStep | read-write | current | In-fan low speed step in tenths of a percent per second |
| 1.3.6.1.4.1.21239.5.2.30.1.7.1.4 | ColumnvrcInFanCfgHighSpeedStep | read-write | current | In-fan high speed step in tenths of a percent per second |
| 1.3.6.1.4.1.21239.5.2.30.1.7.1.5 | ColumnvrcInFanCfgMinSpeed | read-write | current | Min in-fan speed (percent) |
| 1.3.6.1.4.1.21239.5.2.30.1.7.1.6 | ColumnvrcInFanCfgStandardSpeed | read-write | current | Standard in-fan speed (percent) |
| 1.3.6.1.4.1.21239.5.2.30.1.7.1.7 | ColumnvrcInFanCfgMinCfc | read-write | current | Min in-fan cfc (percent) |
| 1.3.6.1.4.1.21239.5.2.30.1.7.1.8 | ColumnvrcInFanCfgStandardCfc | read-write | current | Standard in-fan cfc (percent) |
| 1.3.6.1.4.1.21239.5.2.30.1.7.1.9 | ColumnvrcInFanCfgStartDelay | read-write | current | In-fan start delay in seconds |
| 1.3.6.1.4.1.21239.5.2.30.1.7.1.10 | ColumnvrcInFanCfgStopDelay | read-write | current | In-fan stop delay in seconds |
| 1.3.6.1.4.1.21239.5.2.30.1.7.1.11 | ColumnvrcInFanCfgReduceSpeedDelay | read-write | current | In-fan reduce speed delay in seconds |
| 1.3.6.1.4.1.21239.5.2.30.1.7.1.12 | ColumnvrcInFanCfgJumpBand1 | read-write | current | In-fan jump band 1 in tenths of a percent |
| 1.3.6.1.4.1.21239.5.2.30.1.7.1.13 | ColumnvrcInFanCfgJumpBand2 | read-write | current | In-fan jump band 2 in tenths of a percent |
| 1.3.6.1.4.1.21239.5.2.30.1.7.1.14 | ColumnvrcInFanCfgJumpBand3 | read-write | current | In-fan jump band 3 in tenths of a percent |
| 1.3.6.1.4.1.21239.5.2.30.1.7.1.15 | ColumnvrcInFanCfgJumpBand4 | read-write | current | In-fan jump band 4 in tenths of a percent |
| 1.3.6.1.4.1.21239.5.2.30.1.7.1.16 | ColumnvrcInFanCfgJumpBand5 | read-write | current | In-fan jump band 5 in tenths of a percent |
| 1.3.6.1.4.1.21239.5.2.30.1.7.1.17 | ColumnvrcInFanCfgJumpFreq1 | read-write | current | In-fan jump frequency 1 in tenths of a percent |
| 1.3.6.1.4.1.21239.5.2.30.1.7.1.18 | ColumnvrcInFanCfgJumpFreq2 | read-write | current | In-fan jump frequency 2 in tenths of a percent |
| 1.3.6.1.4.1.21239.5.2.30.1.7.1.19 | ColumnvrcInFanCfgJumpFreq3 | read-write | current | In-fan jump frequency 3 in tenths of a percent |
| 1.3.6.1.4.1.21239.5.2.30.1.7.1.20 | ColumnvrcInFanCfgJumpFreq4 | read-write | current | In-fan jump frequency 4 in tenths of a percent |
| 1.3.6.1.4.1.21239.5.2.30.1.7.1.21 | ColumnvrcInFanCfgJumpFreq5 | read-write | current | In-fan jump frequency 5 in tenths of a percent |
| 1.3.6.1.4.1.21239.5.2.30.1.7.1.22 | ColumnvrcInFanCfgTempP | read-write | current | In-fan temperature P in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. |
| 1.3.6.1.4.1.21239.5.2.30.1.7.1.23 | ColumnvrcInFanCfgTempI | read-write | current | In-fan temperature I in seconds |
| 1.3.6.1.4.1.21239.5.2.30.1.7.1.24 | ColumnvrcInFanCfgTempD | read-write | current | In-fan temperature D in seconds |
| 1.3.6.1.4.1.21239.5.2.30.1.8 | TablevrcCompPtTable | not-accessible | current | Table that contains VRC compressor status |
| 1.3.6.1.4.1.21239.5.2.30.1.8.1 | RowvrcCompPtEntry | not-accessible | current | Entry in the vrcCompPtTable: each entry represents data for a VRC compressor |
| 1.3.6.1.4.1.21239.5.2.30.1.8.1.1 | ColumnvrcCompPtIndex | not-accessible | current | Unique id for each entry in the table |
| 1.3.6.1.4.1.21239.5.2.30.1.8.1.2 | ColumnvrcCompPtName | read-only | current | Compressor name (factory-assigned) |
| 1.3.6.1.4.1.21239.5.2.30.1.8.1.3 | ColumnvrcCompPtCapacity | read-only | current | Compressor capacity value (percent) |
| 1.3.6.1.4.1.21239.5.2.30.1.8.1.4 | ColumnvrcCompPtRunTimeHours | read-only | current | Compressor run time in hours |
| 1.3.6.1.4.1.21239.5.2.30.1.8.1.5 | ColumnvrcCompPtStartStopCount | read-only | current | Compressor start/stop count |
| 1.3.6.1.4.1.21239.5.2.30.1.8.1.6 | ColumnvrcCompPtDriverFaultU00 | read-only | current | Compressor driver fault alarm U00 state |
| 1.3.6.1.4.1.21239.5.2.30.1.8.1.7 | ColumnvrcCompPtDriverFaultU01 | read-only | current | Compressor driver fault alarm U01 state |
| 1.3.6.1.4.1.21239.5.2.30.1.8.1.8 | ColumnvrcCompPtDriverFaultU02 | read-only | current | Compressor driver fault alarm U02 state |
| 1.3.6.1.4.1.21239.5.2.30.1.8.1.9 | ColumnvrcCompPtDriverFaultU03 | read-only | current | Compressor driver fault alarm U03 state |
| 1.3.6.1.4.1.21239.5.2.30.1.8.1.10 | ColumnvrcCompPtDriverFaultU04 | read-only | current | Compressor driver fault alarm U04 state |
| 1.3.6.1.4.1.21239.5.2.30.1.8.1.11 | ColumnvrcCompPtDriverFaultU05 | read-only | current | Compressor driver fault alarm U05 state |
| 1.3.6.1.4.1.21239.5.2.30.1.8.1.12 | ColumnvrcCompPtDriverFaultU06 | read-only | current | Compressor driver fault alarm U06 state |
| 1.3.6.1.4.1.21239.5.2.30.1.8.1.13 | ColumnvrcCompPtDriverFaultU07 | read-only | current | Compressor driver fault alarm U07 state |
| 1.3.6.1.4.1.21239.5.2.30.1.8.1.14 | ColumnvrcCompPtDriverFaultU08 | read-only | current | Compressor driver fault alarm U08 state |
| 1.3.6.1.4.1.21239.5.2.30.1.8.1.15 | ColumnvrcCompPtDriverFaultU09 | read-only | current | Compressor driver fault alarm U09 state |
| 1.3.6.1.4.1.21239.5.2.30.1.8.1.16 | ColumnvrcCompPtDriverFaultU10 | read-only | current | Compressor driver fault alarm U10 state |
| 1.3.6.1.4.1.21239.5.2.30.1.8.1.17 | ColumnvrcCompPtDriverFaultU11 | read-only | current | Compressor driver fault alarm U11 state |
| 1.3.6.1.4.1.21239.5.2.30.1.8.1.18 | ColumnvrcCompPtDriverFaultU12 | read-only | current | Compressor driver fault alarm U12 state |
| 1.3.6.1.4.1.21239.5.2.30.1.8.1.19 | ColumnvrcCompPtDriverFaultU13 | read-only | current | Compressor driver fault alarm U13 state |
| 1.3.6.1.4.1.21239.5.2.30.1.8.1.20 | ColumnvrcCompPtDriverFaultU14 | read-only | current | Compressor driver fault alarm U14 state |
| 1.3.6.1.4.1.21239.5.2.30.1.8.1.21 | ColumnvrcCompPtDriverFaultU15 | read-only | current | Compressor driver fault alarm U15 state |
| 1.3.6.1.4.1.21239.5.2.30.1.8.1.22 | ColumnvrcCompPtDriverCommFailAlarm | read-only | current | Compressor driver communication failure alarm state |
| 1.3.6.1.4.1.21239.5.2.30.1.8.1.23 | ColumnvrcCompPtFaultLockAlarm | read-only | current | Compressor fault lock alarm state |
| 1.3.6.1.4.1.21239.5.2.30.1.9 | TablevrcCompCfgTable | not-accessible | current | Table used for VRC compressor configuration |
| 1.3.6.1.4.1.21239.5.2.30.1.9.1 | RowvrcCompCfgEntry | not-accessible | current | Entry in the vrcCompCfgTable: each entry contains config fields for a VRC compressor |
| 1.3.6.1.4.1.21239.5.2.30.1.9.1.1 | ColumnvrcCompCfgIndex | not-accessible | current | Unique id for each entry in the table |
| 1.3.6.1.4.1.21239.5.2.30.1.9.1.2 | ColumnvrcCompCfgOutputStatus | read-write | current | Compressor output status |
| 1.3.6.1.4.1.21239.5.2.30.1.9.1.3 | ColumnvrcCompCfgOutputDeadBand | read-write | current | Compressor output dead band in tenths of a percent |
| 1.3.6.1.4.1.21239.5.2.30.1.9.1.4 | ColumnvrcCompCfgCapacityOutputValue | read-write | current | Compressor capacity output (percent) |
| 1.3.6.1.4.1.21239.5.2.30.1.9.1.5 | ColumnvrcCompCfgMinCapacity | read-write | current | Compressor min capacity (percent) |
| 1.3.6.1.4.1.21239.5.2.30.1.9.1.6 | ColumnvrcCompCfgStartCapacity | read-write | current | Compressor start capacity (percent) |
| 1.3.6.1.4.1.21239.5.2.30.1.9.1.7 | ColumnvrcCompCfgStandardCapacity | read-write | current | Compressor standard capacity (percent) |
| 1.3.6.1.4.1.21239.5.2.30.1.9.1.8 | ColumnvrcCompCfgStartCfc | read-write | current | Compressor start cfc (percent) |
| 1.3.6.1.4.1.21239.5.2.30.1.9.1.9 | ColumnvrcCompCfgStopCfc | read-write | current | Compressor stop cfc (percent) |
| 1.3.6.1.4.1.21239.5.2.30.1.9.1.10 | ColumnvrcCompCfgMinRunTime | read-write | current | Compressor min run time in minutes |
| 1.3.6.1.4.1.21239.5.2.30.1.9.1.11 | ColumnvrcCompCfgMinStopTime | read-write | current | Compressor min stop time in minutes |
| 1.3.6.1.4.1.21239.5.2.30.1.9.1.12 | ColumnvrcCompCfgJumpBand1 | read-write | current | Compressor jump band 1 in tenths of a percent |
| 1.3.6.1.4.1.21239.5.2.30.1.9.1.13 | ColumnvrcCompCfgJumpBand2 | read-write | current | Compressor jump band 2 in tenths of a percent |
| 1.3.6.1.4.1.21239.5.2.30.1.9.1.14 | ColumnvrcCompCfgJumpBand3 | read-write | current | Compressor jump band 3 in tenths of a percent |
| 1.3.6.1.4.1.21239.5.2.30.1.9.1.15 | ColumnvrcCompCfgJumpBand4 | read-write | current | Compressor jump band 4 in tenths of a percent |
| 1.3.6.1.4.1.21239.5.2.30.1.9.1.16 | ColumnvrcCompCfgJumpBand5 | read-write | current | Compressor jump band 5 in tenths of a percent |
| 1.3.6.1.4.1.21239.5.2.30.1.9.1.17 | ColumnvrcCompCfgJumpFreq1 | read-write | current | Compressor jump frequency 1 in tenths of a percent |
| 1.3.6.1.4.1.21239.5.2.30.1.9.1.18 | ColumnvrcCompCfgJumpFreq2 | read-write | current | Compressor jump frequency 2 in tenths of a percent |
| 1.3.6.1.4.1.21239.5.2.30.1.9.1.19 | ColumnvrcCompCfgJumpFreq3 | read-write | current | Compressor jump frequency 3 in tenths of a percent |
| 1.3.6.1.4.1.21239.5.2.30.1.9.1.20 | ColumnvrcCompCfgJumpFreq4 | read-write | current | Compressor jump frequency 4 in tenths of a percent |
| 1.3.6.1.4.1.21239.5.2.30.1.9.1.21 | ColumnvrcCompCfgJumpFreq5 | read-write | current | Compressor jump frequency 5 in tenths of a percent |
| 1.3.6.1.4.1.21239.5.2.30.1.9.1.22 | ColumnvrcCompCfgTempP | read-write | current | Compressor temperature P in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The settable range is determined by the current temper… |
| 1.3.6.1.4.1.21239.5.2.30.1.9.1.23 | ColumnvrcCompCfgTempI | read-write | current | Compressor temperature I in seconds |
| 1.3.6.1.4.1.21239.5.2.30.1.9.1.24 | ColumnvrcCompCfgTempD | read-write | current | Compressor temperature D in seconds |
| 1.3.6.1.4.1.21239.5.2.30.1.9.1.25 | ColumnvrcCompCfgDriverFaultAlmCtrl | read-write | current | Compressor driver fault alarm control: 2 = suspend 3 = open |
| 1.3.6.1.4.1.21239.5.2.30.1.9.1.26 | ColumnvrcCompCfgDriverCommFailAlmCtrl | read-write | current | Compressor driver communication failure alarm control: 2 = suspend 3 = open |
| 1.3.6.1.4.1.21239.5.2.30.1.9.1.27 | ColumnvrcCompCfgFaultLockAlmCtrl | read-write | current | Compressor fault lock alarm control: 2 = suspend 3 = open |
| 1.3.6.1.4.1.21239.5.2.30.1.10 | TablevrcReturnPtTable | not-accessible | current | Table that contains VRC return status |
| 1.3.6.1.4.1.21239.5.2.30.1.10.1 | RowvrcReturnPtEntry | not-accessible | current | Entry in the vrcReturnPtTable: each entry represents return data for a VRC |
| 1.3.6.1.4.1.21239.5.2.30.1.10.1.1 | ColumnvrcReturnPtIndex | not-accessible | current | Unique id for each entry in the table |
| 1.3.6.1.4.1.21239.5.2.30.1.10.1.2 | ColumnvrcReturnPtName | read-only | current | Return name (factory-assigned) |
| 1.3.6.1.4.1.21239.5.2.30.1.10.1.3 | ColumnvrcReturnPtTemp | read-only | current | Return temperature value in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The range is determined by the current temperature uni… |
| 1.3.6.1.4.1.21239.5.2.30.1.10.1.4 | ColumnvrcReturnPtHighTempAlarm | read-only | current | Return high temperature alarm state |
| 1.3.6.1.4.1.21239.5.2.30.1.10.1.5 | ColumnvrcReturnPtTempSensorFailAlarm | read-only | current | Return temperature sensor failure alarm state |
| 1.3.6.1.4.1.21239.5.2.30.1.11 | TablevrcReturnCfgTable | not-accessible | current | Table used for VRC return configuration |
| 1.3.6.1.4.1.21239.5.2.30.1.11.1 | RowvrcReturnCfgEntry | not-accessible | current | Entry in the vrcReturnCfgTable: each entry contains config fields for VRC return |
| 1.3.6.1.4.1.21239.5.2.30.1.11.1.1 | ColumnvrcReturnCfgIndex | not-accessible | current | Unique id for each entry in the table |
| 1.3.6.1.4.1.21239.5.2.30.1.11.1.2 | ColumnvrcReturnCfgOilCycle | read-write | current | Return oil cycle in tenths of an hour |
| 1.3.6.1.4.1.21239.5.2.30.1.11.1.3 | ColumnvrcReturnCfgOilRunCapacity | read-write | current | Return Oil run capacity (percent) |
| 1.3.6.1.4.1.21239.5.2.30.1.11.1.4 | ColumnvrcReturnCfgOilRunTime | read-write | current | Return oil run time in minutes |
| 1.3.6.1.4.1.21239.5.2.30.1.11.1.5 | ColumnvrcReturnCfgTempCalValue | read-write | current | Return temperature calibration value in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The settable range is determined by the cu… |
| 1.3.6.1.4.1.21239.5.2.30.1.11.1.6 | ColumnvrcReturnCfgTempSetting | read-write | current | Return temperature setting in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The settable range is determined by the current temp… |
| 1.3.6.1.4.1.21239.5.2.30.1.11.1.7 | ColumnvrcReturnCfgHighTempAlarmValue | read-write | current | Return high temperature alarm value in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The settable range is determined by the cur… |
| 1.3.6.1.4.1.21239.5.2.30.1.11.1.8 | ColumnvrcReturnCfgHighTempAlarmCtrl | read-write | current | Return high temperature alarm control: 1 = close 2 = suspend 3 = open |
| 1.3.6.1.4.1.21239.5.2.30.1.11.1.9 | ColumnvrcReturnCfgTempSensFailAlmCtrl | read-write | current | Return temperature sensor failure alarm control: 1 = close 2 = suspend 3 = open |
| 1.3.6.1.4.1.21239.5.2.30.1.12 | TablevrcSupplyPtTable | not-accessible | current | Table that contains VRC supply status |
| 1.3.6.1.4.1.21239.5.2.30.1.12.1 | RowvrcSupplyPtEntry | not-accessible | current | Entry in the vrcSupplyPtTable: each entry represents supply data for a VRC |
| 1.3.6.1.4.1.21239.5.2.30.1.12.1.1 | ColumnvrcSupplyPtIndex | not-accessible | current | Unique id for each entry in the table |
| 1.3.6.1.4.1.21239.5.2.30.1.12.1.2 | ColumnvrcSupplyPtName | read-only | current | Supply name (factory-assigned) |
| 1.3.6.1.4.1.21239.5.2.30.1.12.1.3 | ColumnvrcSupplyPtTemp | read-only | current | Supply temperature value in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The range is determined by the current temperature uni… |
| 1.3.6.1.4.1.21239.5.2.30.1.12.1.4 | ColumnvrcSupplyPtLowTempAlarm | read-only | current | Supply low temperature alarm state |
| 1.3.6.1.4.1.21239.5.2.30.1.12.1.5 | ColumnvrcSupplyPtHighTempAlarm | read-only | current | Supply high temperature alarm state |
| 1.3.6.1.4.1.21239.5.2.30.1.12.1.6 | ColumnvrcSupplyPtTempSensorFailAlarm | read-only | current | Supply temperature sensor failure alarm state |
| 1.3.6.1.4.1.21239.5.2.30.1.13 | TablevrcSupplyCfgTable | not-accessible | current | Table used for VRC supply configuration |
| 1.3.6.1.4.1.21239.5.2.30.1.13.1 | RowvrcSupplyCfgEntry | not-accessible | current | Entry in the vrcSupplyCfgTable: each entry contains config fields for a VRC supply |
| 1.3.6.1.4.1.21239.5.2.30.1.13.1.1 | ColumnvrcSupplyCfgIndex | not-accessible | current | Unique id for each entry in the table |
| 1.3.6.1.4.1.21239.5.2.30.1.13.1.2 | ColumnvrcSupplyCfgTempCalValue | read-write | current | Supply temperature calibration value in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The settable range is determined by the cu… |
| 1.3.6.1.4.1.21239.5.2.30.1.13.1.3 | ColumnvrcSupplyCfgTempSetting | read-write | current | Supply temperature setting in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The settable range is determined by the current temp… |
| 1.3.6.1.4.1.21239.5.2.30.1.13.1.4 | ColumnvrcSupplyCfgLowTempAlarmValue | read-write | current | Supply low temperature alarm value in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The settable range is determined by the curr… |
| 1.3.6.1.4.1.21239.5.2.30.1.13.1.5 | ColumnvrcSupplyCfgHighTempAlarmValue | read-write | current | Supply high temperature alarm value in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The settable range is determined by the cur… |
| 1.3.6.1.4.1.21239.5.2.30.1.13.1.6 | ColumnvrcSupplyCfgLowTempAlmCtrl | read-write | current | Supply low temperature alarm control: 1 = close 2 = suspend 3 = open |
| 1.3.6.1.4.1.21239.5.2.30.1.13.1.7 | ColumnvrcSupplyCfgHighTempAlmCtrl | read-write | current | Supply high temperature alarm control: 1 = close 2 = suspend 3 = open |
| 1.3.6.1.4.1.21239.5.2.30.1.13.1.8 | ColumnvrcSupplyCfgTempSensFailAlmCtrl | read-write | current | Supply temperature sensor failure alarm control: 1 = close 2 = suspend 3 = open |
| 1.3.6.1.4.1.21239.5.2.30.1.14 | TablevrcPowerPtTable | not-accessible | current | Table that contains VRC power status |
| 1.3.6.1.4.1.21239.5.2.30.1.14.1 | RowvrcPowerPtEntry | not-accessible | current | Entry in the vrcPowerPtTable: each entry represents power data for a VRC |
| 1.3.6.1.4.1.21239.5.2.30.1.14.1.1 | ColumnvrcPowerPtIndex | not-accessible | current | Unique id for each entry in the table |
| 1.3.6.1.4.1.21239.5.2.30.1.14.1.2 | ColumnvrcPowerPtName | read-only | current | Power name (factory-assigned) |
| 1.3.6.1.4.1.21239.5.2.30.1.14.1.3 | ColumnvrcPowerPtVoltage | read-only | current | Power voltage measurement in tenths of a volt |
| 1.3.6.1.4.1.21239.5.2.30.1.14.1.4 | ColumnvrcPowerPtFrequency | read-only | current | Power frequency measurement in tenths of hertz |
| 1.3.6.1.4.1.21239.5.2.30.1.14.1.5 | ColumnvrcPowerPtLowVoltageAlarm | read-only | current | Power low voltage alarm state |
| 1.3.6.1.4.1.21239.5.2.30.1.14.1.6 | ColumnvrcPowerPtHighVoltageAlarm | read-only | current | Power high voltage alarm state |
| 1.3.6.1.4.1.21239.5.2.30.1.14.1.7 | ColumnvrcPowerPtLossOfPhasePowerAlarm | read-only | current | Phase power loss alarm state |
| 1.3.6.1.4.1.21239.5.2.30.1.14.1.8 | ColumnvrcPowerPtLossOfPowerAlarm | read-only | current | Power loss alarm state |
| 1.3.6.1.4.1.21239.5.2.30.1.14.1.9 | ColumnvrcPowerPtFrequencyErrorAlarm | read-only | current | Power frequency error alarm state |
| 1.3.6.1.4.1.21239.5.2.30.1.15 | TablevrcPowerCfgTable | not-accessible | current | Table used for VRC power configuration |
| 1.3.6.1.4.1.21239.5.2.30.1.15.1 | RowvrcPowerCfgEntry | not-accessible | current | Entry in the vrcPowerCfgTable: each entry contains config fields for VRC power |
| 1.3.6.1.4.1.21239.5.2.30.1.15.1.1 | ColumnvrcPowerCfgIndex | not-accessible | current | Unique id for each entry in the table |
| 1.3.6.1.4.1.21239.5.2.30.1.15.1.2 | ColumnvrcPowerCfgLowVoltageSetting | read-write | current | Power low voltage setting in volts |
| 1.3.6.1.4.1.21239.5.2.30.1.15.1.3 | ColumnvrcPowerCfgHighVoltageSetting | read-write | current | Power high voltage setting in volts |
| 1.3.6.1.4.1.21239.5.2.30.1.15.1.4 | ColumnvrcPowerCfgLowVoltageAlarmCtrl | read-write | current | Power low voltage alarm control: 1 = close 2 = suspend 3 = open |
| 1.3.6.1.4.1.21239.5.2.30.1.15.1.5 | ColumnvrcPowerCfgHighVoltageAlarmCtrl | read-write | current | Power high voltage alarm control: 1 = close 2 = suspend 3 = open |
| 1.3.6.1.4.1.21239.5.2.30.1.15.1.6 | ColumnvrcPowerCfgLossOfPowerAlarmCtrl | read-write | current | Power loss alarm control: 1 = close 2 = suspend 3 = open |
| 1.3.6.1.4.1.21239.5.2.30.1.15.1.7 | ColumnvrcPowerCfgFreqErrorAlarmCtrl | read-write | current | Power frequency error alarm control: 1 = close 2 = suspend 3 = open |
| 1.3.6.1.4.1.21239.5.2.30.1.16 | TablevrcOutdoorPtTable | not-accessible | current | Table that contains VRC outdoor status |
| 1.3.6.1.4.1.21239.5.2.30.1.16.1 | RowvrcOutdoorPtEntry | not-accessible | current | Entry in the vrcOutdoorPtTable: each entry represents data for a VRC outdoor |
| 1.3.6.1.4.1.21239.5.2.30.1.16.1.1 | ColumnvrcOutdoorPtIndex | not-accessible | current | Unique id for each entry in the table |
| 1.3.6.1.4.1.21239.5.2.30.1.16.1.2 | ColumnvrcOutdoorPtName | read-only | current | Outdoor name (factory-assigned) |
| 1.3.6.1.4.1.21239.5.2.30.1.16.1.3 | ColumnvrcOutdoorPtTemp | read-only | current | Outdoor temperature value in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The range is determined by the current temperature un… |
| 1.3.6.1.4.1.21239.5.2.30.1.18 | TablevrcDischPtTable | not-accessible | current | Table that contains VRC discharge status |
| 1.3.6.1.4.1.21239.5.2.30.1.18.1 | RowvrcDischPtEntry | not-accessible | current | Entry in the vrcDischPtTable: each entry represents discharge data for a VRC |
| 1.3.6.1.4.1.21239.5.2.30.1.18.1.1 | ColumnvrcDischPtIndex | not-accessible | current | Unique id for each entry in the table |
| 1.3.6.1.4.1.21239.5.2.30.1.18.1.2 | ColumnvrcDischPtName | read-only | current | Discharge name (factory-assigned) |
| 1.3.6.1.4.1.21239.5.2.30.1.18.1.3 | ColumnvrcDischPtTemp | read-write | current | Discharge temperature value in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The range is determined by the current temperature … |
| 1.3.6.1.4.1.21239.5.2.30.1.18.1.4 | ColumnvrcDischPtPressure | read-write | current | Discharge air pressure value in tenths of a bar |
| 1.3.6.1.4.1.21239.5.2.30.1.18.1.5 | ColumnvrcDischPtHighTempAlarm | read-only | current | Discharge high temperature alarm state |
| 1.3.6.1.4.1.21239.5.2.30.1.18.1.6 | ColumnvrcDischPtHighTempFreqAlarm | read-only | current | Discharge high temperature frequently alarm state |
| 1.3.6.1.4.1.21239.5.2.30.1.18.1.7 | ColumnvrcDischPtTempSensorFailAlarm | read-only | current | Discharge temperature sensor failure alarm state |
| 1.3.6.1.4.1.21239.5.2.30.1.19 | TablevrcDischCfgTable | not-accessible | current | Table used for VRC discharge configuration |
| 1.3.6.1.4.1.21239.5.2.30.1.19.1 | RowvrcDischCfgEntry | not-accessible | current | Entry in the vrcDischCfgTable: each entry contains config fields for VRC discharge |
| 1.3.6.1.4.1.21239.5.2.30.1.19.1.1 | ColumnvrcDischCfgIndex | not-accessible | current | Unique id for each entry in the table |
| 1.3.6.1.4.1.21239.5.2.30.1.19.1.2 | ColumnvrcDischCfgTempCalValue | read-write | current | Discharge temperature calibration value in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The settable range is determined by the… |
| 1.3.6.1.4.1.21239.5.2.30.1.19.1.3 | ColumnvrcDischCfgPressCalValue | read-write | current | Discharge pressure calibration value in tenths of a bar |
| 1.3.6.1.4.1.21239.5.2.30.1.19.1.4 | ColumnvrcDischCfgHighTempAlmCtrl | read-write | current | Discharge high temperature alarm control: 2 = suspend 3 = open |
| 1.3.6.1.4.1.21239.5.2.30.1.19.1.5 | ColumnvrcDischCfgHighTempFreqAlmCtrl | read-write | current | Discharge high temperature frequenctly alarm control: 2 = suspend 3 = open |
| 1.3.6.1.4.1.21239.5.2.30.1.19.1.6 | ColumnvrcDischCfgTempSensFailAlmCtrl | read-write | current | Discharge temperature sensor failure alarm control: 2 = suspend 3 = open |
| 1.3.6.1.4.1.21239.5.2.30.1.20 | TablevrcSuctPtTable | not-accessible | current | Table that contains VRC suction status |
| 1.3.6.1.4.1.21239.5.2.30.1.20.1 | RowvrcSuctPtEntry | not-accessible | current | Entry in the vrcSuctPtTable: each entry represents suction data for a VRC |
| 1.3.6.1.4.1.21239.5.2.30.1.20.1.1 | ColumnvrcSuctPtIndex | not-accessible | current | Unique id for each entry in the table |
| 1.3.6.1.4.1.21239.5.2.30.1.20.1.2 | ColumnvrcSuctPtName | read-only | current | Suction name (factory-assigned) |
| 1.3.6.1.4.1.21239.5.2.30.1.20.1.3 | ColumnvrcSuctPtTemp | read-only | current | Suction temperature in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The range is determined by the current temperature units. C… |
| 1.3.6.1.4.1.21239.5.2.30.1.20.1.4 | ColumnvrcSuctPtPressure | read-only | current | Suction air pressure in tenths of a bar |
| 1.3.6.1.4.1.21239.5.2.30.1.20.1.5 | ColumnvrcSuctPtSuperHeatTemp | read-only | current | Suction super heat temperature in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The range is determined by the current temperatu… |
| 1.3.6.1.4.1.21239.5.2.30.1.20.1.6 | ColumnvrcSuctPtTempSensorFailAlarm | read-only | current | Suction temperature sensor failure alarm state |
| 1.3.6.1.4.1.21239.5.2.30.1.21 | TablevrcSuctCfgTable | not-accessible | current | Table used for VRC suction configuration |
| 1.3.6.1.4.1.21239.5.2.30.1.21.1 | RowvrcSuctCfgEntry | not-accessible | current | Entry in the vrcSuctCfgTable: each entry contains config fields for VRC suction |
| 1.3.6.1.4.1.21239.5.2.30.1.21.1.1 | ColumnvrcSuctCfgIndex | not-accessible | current | Unique id for each entry in the table |
| 1.3.6.1.4.1.21239.5.2.30.1.21.1.2 | ColumnvrcSuctCfgPressCalValue | read-write | current | Suction pressure calibration value in tenths of a bar |
| 1.3.6.1.4.1.21239.5.2.30.1.21.1.3 | ColumnvrcSuctCfgTempSensFailAlmCtrl | read-write | current | Suction temperature sensor failure alarm control: 2 = suspend 3 = open |
| 1.3.6.1.4.1.21239.5.2.32767 | Nodetrap | |||
| 1.3.6.1.4.1.21239.5.2.32767.0 | NodetrapPrefix | |||
| 1.3.6.1.4.1.21239.5.2.32767.0.10101 | NotificationinternalTestNOTIFY | current | Test SNMP Trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.10305 | NotificationpduMainAvailNOTIFY | current | PDU availability trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.10309 | NotificationpduTotalRealPowerNOTIFY | current | PDU total real power trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.10310 | NotificationpduTotalApparentPowerNOTIFY | current | PDU total apparent power trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.10311 | NotificationpduTotalPowerFactorNOTIFY | current | PDU total power factor trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.10312 | NotificationpduTotalEnergyNOTIFY | current | PDU total energy trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.10324 | NotificationpduPhaseVoltageNOTIFY | current | PDU phase voltage trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.10328 | NotificationpduPhaseCurrentNOTIFY | current | PDU phase current trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.10332 | NotificationpduPhaseRealPowerNOTIFY | current | PDU phase real power trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.10333 | NotificationpduPhaseApparentPowerNOTIFY | current | PDU phase apparent power trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.10334 | NotificationpduPhasePowerFactorNOTIFY | current | PDU phase power factor trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.10335 | NotificationpduPhaseEnergyNOTIFY | current | PDU phase energy trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.10337 | NotificationpduPhaseBalanceNOTIFY | current | PDU phase balance trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.10339 | NotificationpduPhaseCurrentCrestFactorNOTIFY | current | PDU phase current crest factor trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.10354 | NotificationpduBreakerCurrentNOTIFY | current | PDU breaker current trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.10358 | NotificationpduBreakerVoltageNOTIFY | current | PDU breaker voltage trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.10362 | NotificationpduBreakerRealPowerNOTIFY | current | PDU breaker real power trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.10363 | NotificationpduBreakerApparentPowerNOTIFY | current | PDU breaker apparent power trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.10364 | NotificationpduBreakerPowerFactorNOTIFY | current | PDU breaker power factor trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.10365 | NotificationpduBreakerEnergyNOTIFY | current | PDU breaker energy trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.10374 | NotificationpduLineCurrentNOTIFY | current | PDU line current trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.10385 | NotificationpduOutletMeterVoltageNOTIFY | current | PDU outlet voltage trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.10389 | NotificationpduOutletMeterCurrentNOTIFY | current | PDU outlet current trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.10393 | NotificationpduOutletMeterRealPowerNOTIFY | current | PDU outlet real power trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.10394 | NotificationpduOutletMeterApparentPowerNOTIFY | current | PDU outlet apparent power trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.10395 | NotificationpduOutletMeterPowerFactorNOTIFY | current | PDU outlet power factor trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.10396 | NotificationpduOutletMeterEnergyNOTIFY | current | PDU outlet energy trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.10400 | NotificationpduOutletCurrentCrestFactorNOTIFY | current | PDU outlet current crest factor trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.10404 | NotificationtempSensorAvailNOTIFY | current | RT availability trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.10405 | NotificationtempSensorTempNOTIFY | current | RT temperature trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.10504 | NotificationairFlowSensorAvailNOTIFY | current | AFHT3 availability trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.10505 | NotificationairFlowSensorTempNOTIFY | current | AFHT3 temperature trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.10506 | NotificationairFlowSensorFlowNOTIFY | current | AFHT3 airflow trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.10507 | NotificationairFlowSensorHumidityNOTIFY | current | AFHT3 humidity trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.10508 | NotificationairFlowSensorDewPointNOTIFY | current | AFHT3 dewpoint trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.10804 | Notificationt3hdSensorAvailNOTIFY | current | T3HD availability trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.10806 | Notificationt3hdSensorIntTempNOTIFY | current | T3HD Internal temperature trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.10807 | Notificationt3hdSensorIntHumidityNOTIFY | current | T3HD Internal humidity trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.10808 | Notificationt3hdSensorIntDewPointNOTIFY | current | T3HD Internal dewpoint trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.10811 | Notificationt3hdSensorExtATempNOTIFY | current | T3HD External A temperature trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.10814 | Notificationt3hdSensorExtBTempNOTIFY | current | T3HD External B temperature trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.10904 | NotificationthdSensorAvailNOTIFY | current | THD availability trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.10905 | NotificationthdSensorTempNOTIFY | current | THD temperature trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.10906 | NotificationthdSensorHumidityNOTIFY | current | THD humidity trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.10907 | NotificationthdSensorDewPointNOTIFY | current | THD dewpoint trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.11104 | Notificationa2dSensorAvailNOTIFY | current | A2D availability trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.11105 | Notificationa2dSensorValueNOTIFY | current | A2D measurement trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.11204 | NotificationhumiditySensorAvailNOTIFY | current | Remote humidity availability trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.11205 | NotificationhumiditySensorValueNOTIFY | current | Remote humidity value trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.11304 | Notificationsn2dSensorAvailNOTIFY | current | SN-2D availability trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.11306 | Notificationsn2dSensorDoor1StateNOTIFY | current | SN-2D Door switch 1 state trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.11309 | Notificationsn2dSensorDoor2StateNOTIFY | current | SN-2D Door switch 2 state trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.12004 | NotificationpduResidualCurrentAggregateNOTIFY | current | PDU residual current aggregate trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.12005 | NotificationpduResidualCurrentDcNOTIFY | current | PDU residual current DC trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.13001 | NotificationvrcMainAvailNOTIFY | current | VRC availability trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.13002 | NotificationvrcOutFanPtSpeedNOTIFY | current | VRC out-fan speed trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.13003 | NotificationvrcCompPtCapacityNOTIFY | current | VRC compressor capacity trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.13004 | NotificationvrcReturnPtTempNOTIFY | current | VRC return temperature trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.13005 | NotificationvrcSupplyPtTempNOTIFY | current | VRC supply temperature trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.13006 | NotificationvrcPowerPtVoltageNOTIFY | current | VRC power voltage trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.13007 | NotificationvrcPowerPtFrequencyNOTIFY | current | VRC power frequency trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.13008 | NotificationvrcOutdoorPtTempNOTIFY | current | VRC outdoor temperature trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.13009 | NotificationvrcDischPtTempNOTIFY | current | VRC discharge temperature trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.13010 | NotificationvrcDischPtPressureNOTIFY | current | VRC discharge pressure trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.13011 | NotificationvrcSuctPtTempNOTIFY | current | VRC suction temperature trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.13012 | NotificationvrcSuctPtPressureNOTIFY | current | VRC suction pressure trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.20305 | NotificationpduMainAvailCLEAR | current | PDU availability clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.20309 | NotificationpduTotalRealPowerCLEAR | current | PDU total real power clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.20310 | NotificationpduTotalApparentPowerCLEAR | current | PDU total apparent power clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.20311 | NotificationpduTotalPowerFactorCLEAR | current | PDU total power factor clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.20312 | NotificationpduTotalEnergyCLEAR | current | PDU total energy clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.20324 | NotificationpduPhaseVoltageCLEAR | current | PDU phase voltage clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.20328 | NotificationpduPhaseCurrentCLEAR | current | PDU phase current clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.20332 | NotificationpduPhaseRealPowerCLEAR | current | PDU phase real power clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.20333 | NotificationpduPhaseApparentPowerCLEAR | current | PDU phase apparent power clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.20334 | NotificationpduPhasePowerFactorCLEAR | current | PDU phase power factor clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.20335 | NotificationpduPhaseEnergyCLEAR | current | PDU phase energy clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.20337 | NotificationpduPhaseBalanceCLEAR | current | PDU phase balance clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.20339 | NotificationpduPhaseCurrentCrestFactorCLEAR | current | PDU phase current crest factor clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.20354 | NotificationpduBreakerCurrentCLEAR | current | PDU breaker current clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.20358 | NotificationpduBreakerVoltageCLEAR | current | PDU breaker voltage clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.20362 | NotificationpduBreakerRealPowerCLEAR | current | PDU breaker real power clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.20363 | NotificationpduBreakerApparentPowerCLEAR | current | PDU breaker apparent power clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.20364 | NotificationpduBreakerPowerFactorCLEAR | current | PDU breaker power factor clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.20365 | NotificationpduBreakerEnergyCLEAR | current | PDU breaker energy clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.20374 | NotificationpduLineCurrentCLEAR | current | PDU line current clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.20385 | NotificationpduOutletMeterVoltageCLEAR | current | PDU outlet voltage clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.20389 | NotificationpduOutletMeterCurrentCLEAR | current | PDU outlet current clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.20393 | NotificationpduOutletMeterRealPowerCLEAR | current | PDU outlet real power clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.20394 | NotificationpduOutletMeterApparentPowerCLEAR | current | PDU outlet apparent power clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.20395 | NotificationpduOutletMeterPowerFactorCLEAR | current | PDU outlet power factor clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.20396 | NotificationpduOutletMeterEnergyCLEAR | current | PDU outlet energy clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.20400 | NotificationpduOutletCurrentCrestFactorCLEAR | current | PDU outlet current crest factor clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.20404 | NotificationtempSensorAvailCLEAR | current | RT availability clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.20405 | NotificationtempSensorTempCLEAR | current | RT temperature clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.20504 | NotificationairFlowSensorAvailCLEAR | current | AFHT3 availability clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.20505 | NotificationairFlowSensorTempCLEAR | current | AFHT3 temperature clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.20506 | NotificationairFlowSensorFlowCLEAR | current | AFHT3 airflow clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.20507 | NotificationairFlowSensorHumidityCLEAR | current | AFHT3 humidity clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.20508 | NotificationairFlowSensorDewPointCLEAR | current | AFHT3 dewpoint clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.20804 | Notificationt3hdSensorAvailCLEAR | current | T3HD availability clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.20806 | Notificationt3hdSensorIntTempCLEAR | current | T3HD Internal temperature clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.20807 | Notificationt3hdSensorIntHumidityCLEAR | current | T3HD Internal humidity clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.20808 | Notificationt3hdSensorIntDewPointCLEAR | current | T3HD Internal dewpoint clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.20811 | Notificationt3hdSensorExtATempCLEAR | current | T3HD External A temperature clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.20814 | Notificationt3hdSensorExtBTempCLEAR | current | T3HD External B temperature clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.20904 | NotificationthdSensorAvailCLEAR | current | THD availability clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.20905 | NotificationthdSensorTempCLEAR | current | THD temperature clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.20906 | NotificationthdSensorHumidityCLEAR | current | THD humidity clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.20907 | NotificationthdSensorDewPointCLEAR | current | THD dewpoint clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.21104 | Notificationa2dSensorAvailCLEAR | current | A2D availability clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.21105 | Notificationa2dSensorValueCLEAR | current | A2D measurement clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.21204 | NotificationhumiditySensorAvailCLEAR | current | Remote humidity availability clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.21205 | NotificationhumiditySensorValueCLEAR | current | Remote humidity value clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.21304 | Notificationsn2dSensorAvailCLEAR | current | SN-2D availability clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.21306 | Notificationsn2dSensorDoor1StateCLEAR | current | SN-2D Door switch 1 state clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.21309 | Notificationsn2dSensorDoor2StateCLEAR | current | SN-2D Door switch 2 state clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.22004 | NotificationpduResidualCurrentAggregateCLEAR | current | PDU residual current aggregate clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.22005 | NotificationpduResidualCurrentDcCLEAR | current | PDU residual current DC clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.23001 | NotificationvrcMainAvailCLEAR | current | VRC availability clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.23002 | NotificationvrcOutFanPtSpeedCLEAR | current | VRC out-fan speed clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.23003 | NotificationvrcCompPtCapacityCLEAR | current | VRC compressor capacity clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.23004 | NotificationvrcReturnPtTempCLEAR | current | VRC return temperature clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.23005 | NotificationvrcSupplyPtTempCLEAR | current | VRC supply temperature clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.23006 | NotificationvrcPowerPtVoltageCLEAR | current | VRC power voltage clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.23007 | NotificationvrcPowerPtFrequencyCLEAR | current | VRC power frequency clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.23008 | NotificationvrcOutdoorPtTempCLEAR | current | VRC outdoor temperature clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.23009 | NotificationvrcDischPtTempCLEAR | current | VRC discharge temperature clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.23010 | NotificationvrcDischPtPressureCLEAR | current | VRC discharge pressure clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.23011 | NotificationvrcSuctPtTempCLEAR | current | VRC suction temperature clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.0.23012 | NotificationvrcSuctPtPressureCLEAR | current | VRC suction pressure clear trap | |
| 1.3.6.1.4.1.21239.5.2.32767.1 | NodetrapObj | |||
| 1.3.6.1.4.1.21239.5.2.32767.1.1 | ScalartrapSeverity | accessible-for-notify | current | Indicates the severity of the trap: 0 = None 1 = Warning 2 = Alarm |
| 1.3.6.1.4.1.21239.5.2.32767.1.2 | ScalartrapThreshType | accessible-for-notify | current | Only sent for threshold alarms. Identifies the threshold type: 1 = Low 2 = High |
| 1.3.6.1.4.1.21239.42 | Nodecommon | |||
| 1.3.6.1.4.1.21239.42.1 | Nodeidentity | |||
| 1.3.6.1.4.1.21239.42.1.15 | Identityr05 | current | Value given for sysObjectID on R-Series units | |
| 1.3.6.1.4.1.21239.42.1.53 | Identityi03 | current | Value given for sysObjectID on IMD3 units |