VERTIV-V5-MIB

584 objects
The MIB for Vertiv products
Imported Objects
SNMP-FRAMEWORK-MIBSnmpAdminString
SNMPv2-MIBsysName
SNMPv2-SMIenterprises Gauge32 Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-IDENTITY OBJECT-TYPE
SNMPv2-TCDisplayString MacAddress TruthValue
OIDNameAccessStatusDescription
1.3.6.1.4.1.21239IdentityvertivThe MIB for Vertiv products
1.3.6.1.4.1.21239.5Nodev5
1.3.6.1.4.1.21239.5.2Nodeimd
1.3.6.1.4.1.21239.5.2.1NodedeviceInfo
1.3.6.1.4.1.21239.5.2.1.1ScalarproductTitleread-onlycurrentProduct name
1.3.6.1.4.1.21239.5.2.1.2ScalarproductVersionread-onlycurrentProduct version
1.3.6.1.4.1.21239.5.2.1.3ScalarproductFriendlyNameread-onlycurrentUser-assigned name
1.3.6.1.4.1.21239.5.2.1.4ScalarproductMacAddressread-onlycurrentProduct's unique MAC address
1.3.6.1.4.1.21239.5.2.1.6ScalardeviceCountread-onlycurrentTotal number of devices on unit
1.3.6.1.4.1.21239.5.2.1.7ScalartemperatureUnitsread-writecurrentCurrent units for temperature/dewpoint values: 0 = Degrees Fahrenheit 1 = Degrees Celsius
1.3.6.1.4.1.21239.5.2.1.8ScalarproductModelNumberread-onlycurrentProduct model number (factory-assigned)
1.3.6.1.4.1.21239.5.2.1.9ScalarproductPartNumberread-onlycurrentProduct part number (factory-assigned)
1.3.6.1.4.1.21239.5.2.1.10ScalarproductSerialNumberread-onlycurrentProduct serial number (factory-assigned)
1.3.6.1.4.1.21239.5.2.1.11ScalarproductPlatformread-onlycurrentProduct platform
1.3.6.1.4.1.21239.5.2.1.12ScalarproductHostnameread-onlycurrentProduct hostname
1.3.6.1.4.1.21239.5.2.1.13ScalarproductAlarmCountread-onlycurrentNumber of alarms currently tripped
1.3.6.1.4.1.21239.5.2.1.14ScalarproductWarnCountread-onlycurrentNumber of warnings currently tripped
1.3.6.1.4.1.21239.5.2.1.15ScalarproductManufacturerread-onlycurrentProduct manufacturer
1.3.6.1.4.1.21239.5.2.3Nodepdu
1.3.6.1.4.1.21239.5.2.3.1TablepduMainTablenot-accessiblecurrentPDU general information
1.3.6.1.4.1.21239.5.2.3.1.1RowpduMainEntrynot-accessiblecurrentEntry in the pduMainTable table: each entry contains an index and other sensor details
1.3.6.1.4.1.21239.5.2.3.1.1.1ColumnpduMainIndexnot-accessiblecurrentTable entry index value
1.3.6.1.4.1.21239.5.2.3.1.1.2ColumnpduMainSerialread-onlycurrentSerial number
1.3.6.1.4.1.21239.5.2.3.1.1.3ColumnpduMainNameread-onlycurrentPDU name (factory-assigned)
1.3.6.1.4.1.21239.5.2.3.1.1.4ColumnpduMainLabelread-writecurrentPDU label (user-defined)
1.3.6.1.4.1.21239.5.2.3.1.1.5ColumnpduMainAvailread-onlycurrentDevice availability: 0 = Unavailable 1 = Available 2 = Partially Unavailable
1.3.6.1.4.1.21239.5.2.3.1.1.6ColumnpduMeterTyperead-onlycurrentCurrent meter type: 0 = Wye 1 = Delta
1.3.6.1.4.1.21239.5.2.3.1.1.7ColumnpduTotalNameread-onlycurrentTotal name (factory-assigned)
1.3.6.1.4.1.21239.5.2.3.1.1.8ColumnpduTotalLabelread-writecurrentTotal label (user-defined)
1.3.6.1.4.1.21239.5.2.3.1.1.9ColumnpduTotalRealPowerread-onlycurrentPDU total real power
1.3.6.1.4.1.21239.5.2.3.1.1.10ColumnpduTotalApparentPowerread-onlycurrentPDU total apparent power
1.3.6.1.4.1.21239.5.2.3.1.1.11ColumnpduTotalPowerFactorread-onlycurrentPDU total power factor
1.3.6.1.4.1.21239.5.2.3.1.1.12ColumnpduTotalEnergyread-onlycurrentPDU total accumulated energy in watt-hours
1.3.6.1.4.1.21239.5.2.3.2TablepduPhaseTablenot-accessiblecurrentPDU phases information
1.3.6.1.4.1.21239.5.2.3.2.1RowpduPhaseEntrynot-accessiblecurrentEntry in the pduPhaseTable table: each entry contains an index and other sensor details
1.3.6.1.4.1.21239.5.2.3.2.1.1ColumnpduPhaseIndexnot-accessiblecurrentTable entry index value
1.3.6.1.4.1.21239.5.2.3.2.1.2ColumnpduPhaseNameread-onlycurrentPDU phase name (factory-assigned)
1.3.6.1.4.1.21239.5.2.3.2.1.3ColumnpduPhaseLabelread-writecurrentPDU phase label (user-defined)
1.3.6.1.4.1.21239.5.2.3.2.1.4ColumnpduPhaseVoltageread-onlycurrentPDU phase voltage in tenths of a volt
1.3.6.1.4.1.21239.5.2.3.2.1.8ColumnpduPhaseCurrentread-onlycurrentPDU phase current reading in hundredths of an amp
1.3.6.1.4.1.21239.5.2.3.2.1.12ColumnpduPhaseRealPowerread-onlycurrentReal power for phase in watts
1.3.6.1.4.1.21239.5.2.3.2.1.13ColumnpduPhaseApparentPowerread-onlycurrentApparent power for phase in volt-amps
1.3.6.1.4.1.21239.5.2.3.2.1.14ColumnpduPhasePowerFactorread-onlycurrentPower factor for phase
1.3.6.1.4.1.21239.5.2.3.2.1.15ColumnpduPhaseEnergyread-onlycurrentAccumulated energy for phase in watt-hours
1.3.6.1.4.1.21239.5.2.3.2.1.17ColumnpduPhaseBalanceread-onlycurrentPhase balance as percent
1.3.6.1.4.1.21239.5.2.3.2.1.19ColumnpduPhaseCurrentCrestFactorread-onlycurrentCurrent crest factor for phase, in hundredths
1.3.6.1.4.1.21239.5.2.3.2.1.20ColumnpduPhaseResCurrentDetectedread-onlycurrentTells if residual current was detected. In normal operation, the value will be false(2).
1.3.6.1.4.1.21239.5.2.3.3TablepduBreakerTablenot-accessiblecurrentPDU breaker information
1.3.6.1.4.1.21239.5.2.3.3.1RowpduBreakerEntrynot-accessiblecurrentEntry in the pduBreakerTable table: each entry contains an index and other sensor details
1.3.6.1.4.1.21239.5.2.3.3.1.1ColumnpduBreakerIndexnot-accessiblecurrentTable entry index value
1.3.6.1.4.1.21239.5.2.3.3.1.2ColumnpduBreakerNameread-onlycurrentPDU breaker name (factory-assigned)
1.3.6.1.4.1.21239.5.2.3.3.1.3ColumnpduBreakerLabelread-writecurrentPDU breaker label (user-defined)
1.3.6.1.4.1.21239.5.2.3.3.1.4ColumnpduBreakerCurrentread-onlycurrentPDU breaker current reading in hundredths of an amp
1.3.6.1.4.1.21239.5.2.3.3.1.8ColumnpduBreakerVoltageread-onlycurrentPDU breaker voltage in tenths of a volt. This object may not exist on all platforms, due to hardware differences.
1.3.6.1.4.1.21239.5.2.3.3.1.12ColumnpduBreakerRealPowerread-onlycurrentReal power for breaker in watts. This object may not exist on all platforms, due to hardware differences.
1.3.6.1.4.1.21239.5.2.3.3.1.13ColumnpduBreakerApparentPowerread-onlycurrentApparent power for breaker in volt-amps. This object may not exist on all platforms, due to hardware differences.
1.3.6.1.4.1.21239.5.2.3.3.1.14ColumnpduBreakerPowerFactorread-onlycurrentPower factor for breaker. This object may not exist on all platforms, due to hardware differences.
1.3.6.1.4.1.21239.5.2.3.3.1.15ColumnpduBreakerEnergyread-onlycurrentAccumulated energy for breaker in watt-hours. This object may not exist on all platforms, due to hardware differences.
1.3.6.1.4.1.21239.5.2.3.3.1.20ColumnpduBreakerResCurrentDetectedread-onlycurrentTells if residual current was detected. In normal operation, the value will be false(2).
1.3.6.1.4.1.21239.5.2.3.3.1.21ColumnpduBreakerLossOfLoadDetectedread-onlycurrentTells if a loss of load was detected. In normal operation, the value will be false(2).
1.3.6.1.4.1.21239.5.2.3.4TablepduLineTablenot-accessiblecurrentPDU line current information
1.3.6.1.4.1.21239.5.2.3.4.1RowpduLineEntrynot-accessiblecurrentEntry in the pduLineTable table: each entry contains an index and other sensor details
1.3.6.1.4.1.21239.5.2.3.4.1.1ColumnpduLineIndexnot-accessiblecurrentTable entry index value
1.3.6.1.4.1.21239.5.2.3.4.1.2ColumnpduLineNameread-onlycurrentPDU line name (factory-assigned)
1.3.6.1.4.1.21239.5.2.3.4.1.3ColumnpduLineLabelread-writecurrentPDU line label (user-defined)
1.3.6.1.4.1.21239.5.2.3.4.1.4ColumnpduLineCurrentread-onlycurrentPDU line current reading in hundredths of an amp
1.3.6.1.4.1.21239.5.2.3.5TablepduOutletSwitchTablenot-accessiblecurrentData, config and control for outlets with switching
1.3.6.1.4.1.21239.5.2.3.5.1RowpduOutletSwitchEntrynot-accessiblecurrentEntry in the pduOutletSwitchTable table: each entry contains an index and other sensor details
1.3.6.1.4.1.21239.5.2.3.5.1.1ColumnpduOutletSwitchIndexnot-accessiblecurrentTable entry index value
1.3.6.1.4.1.21239.5.2.3.5.1.2ColumnpduOutletSwitchNameread-onlycurrentPDU outlet name (factory-assigned)
1.3.6.1.4.1.21239.5.2.3.5.1.3ColumnpduOutletSwitchLabelread-writecurrentPDU outlet label (user-defined)
1.3.6.1.4.1.21239.5.2.3.5.1.4ColumnpduOutletSwitchStateread-onlycurrentSwitch state of the outlet: 1 = Outlet is on 2 = Outlet is off 3 = Outlet is on, but will turn off after a delay 4 = Outlet is off, but will turn on after a de…
1.3.6.1.4.1.21239.5.2.3.5.1.5ColumnpduOutletSwitchRelayFailureread-onlycurrentTells if the outlet relay has failed. In normal operation, the value will be false(2).
1.3.6.1.4.1.21239.5.2.3.5.1.6ColumnpduOutletSwitchControlread-writecurrentUsed for manual control of the outlet. If the outlet is in manual mode, this field can be set to one of the following values: 1 = Cancel pending operation 2 = …
1.3.6.1.4.1.21239.5.2.3.5.1.7ColumnpduOutletSwitchTimeToActionread-onlycurrentSeconds until an outlet state change. The value of pduOutletSwitchState tells what state the outlet will be set, after the delay.
1.3.6.1.4.1.21239.5.2.3.5.1.8ColumnpduOutletSwitchOnDelayread-writecurrentSeconds to wait before powering on the outlet, during onAfterDelay(3) operation. Changing this value has no effect on pending actions.
1.3.6.1.4.1.21239.5.2.3.5.1.9ColumnpduOutletSwitchOffDelayread-writecurrentSeconds to wait before powering off the outlet, during offAfterDelay(5) operation. Changing this value has no effect on pending actions.
1.3.6.1.4.1.21239.5.2.3.5.1.10ColumnpduOutletSwitchRebootDelayread-writecurrentSeconds to wait before powering off the outlet, during rebootAfterDelay(7) operation. Changing this value has no effect on pending actions. See pduOutletSwitch…
1.3.6.1.4.1.21239.5.2.3.5.1.11ColumnpduOutletSwitchRebootHoldDelayread-writecurrentSeconds to hold the outlet off, before powering on the outlet, during rebootAfterDelay(7) operation. Changing this value has no effect on pending actions. See …
1.3.6.1.4.1.21239.5.2.3.5.1.12ColumnpduOutletSwitchPoaActionread-writecurrentThe outlet is set to this state during power-up. The action can be have one the following values: 1 = Outlet will be turned on 2 = Outlet will stay off 3 = Out…
1.3.6.1.4.1.21239.5.2.3.5.1.13ColumnpduOutletSwitchPoaDelayread-writecurrentSeconds to wait before setting the outlet to the pduOutletSwitchPoaAction state. The delay starts at power-up.
1.3.6.1.4.1.21239.5.2.3.6TablepduOutletMeterTablenot-accessiblecurrentMetering data for outlets that support this feature
1.3.6.1.4.1.21239.5.2.3.6.1RowpduOutletMeterEntrynot-accessiblecurrentEntry in the pduOutletMeterTable table: each entry contains an index and other sensor details
1.3.6.1.4.1.21239.5.2.3.6.1.1ColumnpduOutletMeterIndexnot-accessiblecurrentTable entry index value
1.3.6.1.4.1.21239.5.2.3.6.1.2ColumnpduOutletMeterNameread-onlycurrentPDU outlet name (factory-assigned)
1.3.6.1.4.1.21239.5.2.3.6.1.3ColumnpduOutletMeterLabelread-writecurrentPDU outlet label (user-defined)
1.3.6.1.4.1.21239.5.2.3.6.1.4ColumnpduOutletMeterVoltageread-onlycurrentPDU outlet voltage in tenths of a volt
1.3.6.1.4.1.21239.5.2.3.6.1.8ColumnpduOutletMeterCurrentread-onlycurrentPDU outlet current reading in hundredths of an amp
1.3.6.1.4.1.21239.5.2.3.6.1.12ColumnpduOutletMeterRealPowerread-onlycurrentReal power for outlet in watts
1.3.6.1.4.1.21239.5.2.3.6.1.13ColumnpduOutletMeterApparentPowerread-onlycurrentApparent power for outlet in volt-amps
1.3.6.1.4.1.21239.5.2.3.6.1.14ColumnpduOutletMeterPowerFactorread-onlycurrentPower factor for outlet
1.3.6.1.4.1.21239.5.2.3.6.1.15ColumnpduOutletMeterEnergyread-onlycurrentAccumulated energy for outlet in watt-hours
1.3.6.1.4.1.21239.5.2.3.6.1.16ColumnpduOutletMeterResetread-writecurrentUsed to reset energy. If read, the value is none(8). It can be set to resetEnergy(1), which sets outlet energy to 0
1.3.6.1.4.1.21239.5.2.3.6.1.19ColumnpduOutletCurrentCrestFactorread-onlycurrentCurrent crest factor for outlet, in hundredths
1.3.6.1.4.1.21239.5.2.3.7TablepduResidualCurrentTablenot-accessiblecurrentResidual current data for PDUs that support this feature
1.3.6.1.4.1.21239.5.2.3.7.1RowpduResidualCurrentEntrynot-accessiblecurrentEntry in the pduResidualCurrentTable table: each entry contains an index and other sensor details
1.3.6.1.4.1.21239.5.2.3.7.1.1ColumnpduResidualCurrentIndexnot-accessiblecurrentTable entry index value
1.3.6.1.4.1.21239.5.2.3.7.1.2ColumnpduResidualCurrentNameread-onlycurrentPDU residual current name (factory-assigned)
1.3.6.1.4.1.21239.5.2.3.7.1.3ColumnpduResidualCurrentLabelread-onlycurrentPDU residual current label
1.3.6.1.4.1.21239.5.2.3.7.1.4ColumnpduResidualCurrentAggregateread-onlycurrentPDU residual current aggregate value in milliamps
1.3.6.1.4.1.21239.5.2.3.7.1.5ColumnpduResidualCurrentDcread-onlycurrentPDU residual current DC value in milliamps
1.3.6.1.4.1.21239.5.2.4TabletempSensorTablenot-accessiblecurrentRemote Temperature (RT) sensor
1.3.6.1.4.1.21239.5.2.4.1RowtempSensorEntrynot-accessiblecurrentEntry in the tempSensorTable table: each entry contains an index and other sensor details
1.3.6.1.4.1.21239.5.2.4.1.1ColumntempSensorIndexnot-accessiblecurrentTable entry index value
1.3.6.1.4.1.21239.5.2.4.1.2ColumntempSensorSerialread-onlycurrentSerial number
1.3.6.1.4.1.21239.5.2.4.1.3ColumntempSensorLabelread-writecurrentUser-defined label
1.3.6.1.4.1.21239.5.2.4.1.4ColumntempSensorAvailread-onlycurrentDevice availability: 0 = Unavailable 1 = Available 2 = Partially Unavailable
1.3.6.1.4.1.21239.5.2.4.1.5ColumntempSensorTempread-onlycurrentTemperature in tenths of a degree. Units are given by temperatureUnits field in deviceInfo.
1.3.6.1.4.1.21239.5.2.5TableairFlowSensorTablenot-accessiblecurrentRemote Airflow, Humidity, Temperature and Dewpoint (AFHT3) Sensor
1.3.6.1.4.1.21239.5.2.5.1RowairFlowSensorEntrynot-accessiblecurrentEntry in the airFlowSensorTable table: each entry contains an index and other sensor details
1.3.6.1.4.1.21239.5.2.5.1.1ColumnairFlowSensorIndexnot-accessiblecurrentTable entry index value
1.3.6.1.4.1.21239.5.2.5.1.2ColumnairFlowSensorSerialread-onlycurrentSerial number
1.3.6.1.4.1.21239.5.2.5.1.3ColumnairFlowSensorLabelread-writecurrentUser-defined label
1.3.6.1.4.1.21239.5.2.5.1.4ColumnairFlowSensorAvailread-onlycurrentDevice availability: 0 = Unavailable 1 = Available 2 = Partially Unavailable
1.3.6.1.4.1.21239.5.2.5.1.5ColumnairFlowSensorTempread-onlycurrentTemperature reading in tenths of a degree. Units are given by temperatureUnits field in deviceInfo.
1.3.6.1.4.1.21239.5.2.5.1.6ColumnairFlowSensorFlowread-onlycurrentAirflow reading. Still air will be less than 20, while rushing air will be around 100.
1.3.6.1.4.1.21239.5.2.5.1.7ColumnairFlowSensorHumidityread-onlycurrentHumidity reading
1.3.6.1.4.1.21239.5.2.5.1.8ColumnairFlowSensorDewPointread-onlycurrentDewpoint reading in tenths of a degree. Units are given by temperatureUnits field in deviceInfo.
1.3.6.1.4.1.21239.5.2.8Tablet3hdSensorTablenot-accessiblecurrentRemote Temperature x 3, Humidity and Dewpoint Sensor
1.3.6.1.4.1.21239.5.2.8.1Rowt3hdSensorEntrynot-accessiblecurrentEntry in the t3hdSensorTable table: each entry contains an index and other sensor details
1.3.6.1.4.1.21239.5.2.8.1.1Columnt3hdSensorIndexnot-accessiblecurrentTable entry index value
1.3.6.1.4.1.21239.5.2.8.1.2Columnt3hdSensorSerialread-onlycurrentSerial number
1.3.6.1.4.1.21239.5.2.8.1.3Columnt3hdSensorLabelread-writecurrentUser-defined label
1.3.6.1.4.1.21239.5.2.8.1.4Columnt3hdSensorAvailread-onlycurrentDevice availability: 0 = Unavailable 1 = Available 2 = Partially Unavailable
1.3.6.1.4.1.21239.5.2.8.1.5Columnt3hdSensorIntLabelread-writecurrentInternal label (user-defined)
1.3.6.1.4.1.21239.5.2.8.1.6Columnt3hdSensorIntTempread-onlycurrentInternal temperature in tenths of a degree. Units are given by temperatureUnits field in deviceInfo.
1.3.6.1.4.1.21239.5.2.8.1.7Columnt3hdSensorIntHumidityread-onlycurrentInternal humidity
1.3.6.1.4.1.21239.5.2.8.1.8Columnt3hdSensorIntDewPointread-onlycurrentInternal dewpoint in tenths of a degree. Units are given by temperatureUnits field in deviceInfo.
1.3.6.1.4.1.21239.5.2.8.1.9Columnt3hdSensorExtAAvailread-onlycurrentExternal A status: 0 = Unavailable 1 = Available
1.3.6.1.4.1.21239.5.2.8.1.10Columnt3hdSensorExtALabelread-writecurrentExternal A label (user-defined)
1.3.6.1.4.1.21239.5.2.8.1.11Columnt3hdSensorExtATempread-onlycurrentExternal A temperature in tenths of a degree. Units are given by temperatureUnits field in deviceInfo.
1.3.6.1.4.1.21239.5.2.8.1.12Columnt3hdSensorExtBAvailread-onlycurrentExternal B status: 0 = Unavailable 1 = Available
1.3.6.1.4.1.21239.5.2.8.1.13Columnt3hdSensorExtBLabelread-writecurrentExternal B label (user-defined)
1.3.6.1.4.1.21239.5.2.8.1.14Columnt3hdSensorExtBTempread-onlycurrentExternal B temperature in tenths of a degree. Units are given by temperatureUnits field in deviceInfo.
1.3.6.1.4.1.21239.5.2.9TablethdSensorTablenot-accessiblecurrentRemote Temperature, Humidity, and Dewpoint (THD) Sensor
1.3.6.1.4.1.21239.5.2.9.1RowthdSensorEntrynot-accessiblecurrentEntry in the thdSensorTable table: each entry contains an index and other sensor details
1.3.6.1.4.1.21239.5.2.9.1.1ColumnthdSensorIndexnot-accessiblecurrentTable entry index value
1.3.6.1.4.1.21239.5.2.9.1.2ColumnthdSensorSerialread-onlycurrentSerial number
1.3.6.1.4.1.21239.5.2.9.1.3ColumnthdSensorLabelread-writecurrentUser-defined label
1.3.6.1.4.1.21239.5.2.9.1.4ColumnthdSensorAvailread-onlycurrentDevice availability: 0 = Unavailable 1 = Available 2 = Partially Unavailable
1.3.6.1.4.1.21239.5.2.9.1.5ColumnthdSensorTempread-onlycurrentTemperature value in tenths of a degree. Units are given by temperatureUnits field in deviceInfo.
1.3.6.1.4.1.21239.5.2.9.1.6ColumnthdSensorHumidityread-onlycurrentHumidity value
1.3.6.1.4.1.21239.5.2.9.1.7ColumnthdSensorDewPointread-onlycurrentDewpoint value in tenths of a degree. Units are given by temperatureUnits field in deviceInfo.
1.3.6.1.4.1.21239.5.2.11Tablea2dSensorTablenot-accessiblecurrentAnalog measurement (A2D) sensor (voltage, current, or dry-contact)
1.3.6.1.4.1.21239.5.2.11.1Rowa2dSensorEntrynot-accessiblecurrentEntry in the a2dSensorTable table: each entry contains an index and other sensor details
1.3.6.1.4.1.21239.5.2.11.1.1Columna2dSensorIndexnot-accessiblecurrentTable entry index value
1.3.6.1.4.1.21239.5.2.11.1.2Columna2dSensorSerialread-onlycurrentSerial number
1.3.6.1.4.1.21239.5.2.11.1.3Columna2dSensorLabelread-writecurrentUser-defined label
1.3.6.1.4.1.21239.5.2.11.1.4Columna2dSensorAvailread-onlycurrentDevice availability: 0 = Unavailable 1 = Available 2 = Partially Unavailable
1.3.6.1.4.1.21239.5.2.11.1.5Columna2dSensorValueread-onlycurrentAnalog measurement value, within either a user-defined or preset range, depending on a2dSensorMode.
1.3.6.1.4.1.21239.5.2.11.1.6Columna2dSensorDisplayValueread-onlycurrentFor current/voltage modes, the analog value is given as a string. In binary modes, the value is either a2dSensorLowLabel or a2dSensorHighLabel, based on a2dSen…
1.3.6.1.4.1.21239.5.2.11.1.7Columna2dSensorModeread-writecurrentBinary modes have two states represented by the values 0 (low) or 1 (high). These correspond to a2dSensorLowLabel and a2dSensorHighLabel. Current and voltage m…
1.3.6.1.4.1.21239.5.2.11.1.8Columna2dSensorUnitsread-writecurrentThe units for the analog value. If a2dSensorMode is customVoltage(9) or customCurrent(11), then this field has a user-defined value. Otherwise, the value is fi…
1.3.6.1.4.1.21239.5.2.11.1.9Columna2dSensorMinread-writecurrentMinimum analog value, given as an integer. The analog measurement is scaled to the range a2dSensorMin to a2dSensorMax. If a2dSensorMode is customVoltage(9) or …
1.3.6.1.4.1.21239.5.2.11.1.10Columna2dSensorMaxread-writecurrentMaximum analog value, given as an integer. The analog measurement is scaled to the range a2dSensorMin to a2dSensorMax. If a2dSensorMode is customVoltage(9) or …
1.3.6.1.4.1.21239.5.2.11.1.11Columna2dSensorLowLabelread-writecurrentLabel for 0 (low) binary value. This field is only applicable if a2dSensorMode is one of the binary modes. If a2dSensorMode is customBinary(10), then this fiel…
1.3.6.1.4.1.21239.5.2.11.1.12Columna2dSensorHighLabelread-writecurrentLabel for 1 (high) binary value. The field is only applicable if a2dSensorMode is one of the binary modes. If a2dSensorMode is customBinary(10), then this fiel…
1.3.6.1.4.1.21239.5.2.11.1.13Columna2dSensorAnalogLabelread-writecurrentLabel for the analog measurement
1.3.6.1.4.1.21239.5.2.12TablehumiditySensorTablenot-accessiblecurrentRemote humidity sensor
1.3.6.1.4.1.21239.5.2.12.1RowhumiditySensorEntrynot-accessiblecurrentEntry in the humiditySensorTable table: each entry contains an index and other sensor details
1.3.6.1.4.1.21239.5.2.12.1.1ColumnhumiditySensorIndexnot-accessiblecurrentTable entry index value
1.3.6.1.4.1.21239.5.2.12.1.2ColumnhumiditySensorSerialread-onlycurrentSerial number
1.3.6.1.4.1.21239.5.2.12.1.3ColumnhumiditySensorLabelread-writecurrentUser-defined label
1.3.6.1.4.1.21239.5.2.12.1.4ColumnhumiditySensorAvailread-onlycurrentDevice availability: 0 = Unavailable 1 = Available 2 = Partially Unavailable
1.3.6.1.4.1.21239.5.2.12.1.5ColumnhumiditySensorValueread-onlycurrentHumidity value
1.3.6.1.4.1.21239.5.2.13Tablesn2dSensorTablenot-accessiblecurrent2 Door Switch Sensor (SN-2D)
1.3.6.1.4.1.21239.5.2.13.1Rowsn2dSensorEntrynot-accessiblecurrentEntry in the sn2dSensorTable table: each entry contains an index and other sensor details
1.3.6.1.4.1.21239.5.2.13.1.1Columnsn2dSensorIndexnot-accessiblecurrentTable entry index value
1.3.6.1.4.1.21239.5.2.13.1.2Columnsn2dSensorSerialread-onlycurrentSerial number
1.3.6.1.4.1.21239.5.2.13.1.3Columnsn2dSensorLabelread-writecurrentUser-defined label
1.3.6.1.4.1.21239.5.2.13.1.4Columnsn2dSensorAvailread-onlycurrentDevice availability: 0 = Unavailable 1 = Available 2 = Partially Unavailable
1.3.6.1.4.1.21239.5.2.13.1.5Columnsn2dSensorDoor1Labelread-writecurrentDoor switch 1 label
1.3.6.1.4.1.21239.5.2.13.1.6Columnsn2dSensorDoor1Stateread-onlycurrentDoor switch 1 state: 1 = open 2 = closed
1.3.6.1.4.1.21239.5.2.13.1.7Columnsn2dSensorDoor1DisplayStateread-onlycurrentDoor switch 1 state given as a string
1.3.6.1.4.1.21239.5.2.13.1.8Columnsn2dSensorDoor2Labelread-writecurrentDoor switch 2 label
1.3.6.1.4.1.21239.5.2.13.1.9Columnsn2dSensorDoor2Stateread-onlycurrentDoor switch 2 state: 1 = open 2 = closed
1.3.6.1.4.1.21239.5.2.13.1.10Columnsn2dSensorDoor2DisplayStateread-onlycurrentDoor switch 2 state given as a string
1.3.6.1.4.1.21239.5.2.30Nodecooling
1.3.6.1.4.1.21239.5.2.30.1Nodevrc
1.3.6.1.4.1.21239.5.2.30.1.1TablevrcMainTablenot-accessiblecurrentTable that contains general VRC information
1.3.6.1.4.1.21239.5.2.30.1.1.1RowvrcMainEntrynot-accessiblecurrentEntry in the vrcMainTable: each entry represents a VRC device
1.3.6.1.4.1.21239.5.2.30.1.1.1.1ColumnvrcMainIndexnot-accessiblecurrentUnique id for each entry in the table
1.3.6.1.4.1.21239.5.2.30.1.1.1.2ColumnvrcMainSerialread-onlycurrentSerial number
1.3.6.1.4.1.21239.5.2.30.1.1.1.3ColumnvrcMainNameread-onlycurrentVRC name (factory-assigned)
1.3.6.1.4.1.21239.5.2.30.1.1.1.4ColumnvrcMainLabelread-writecurrentVRC label (user-defined)
1.3.6.1.4.1.21239.5.2.30.1.1.1.5ColumnvrcMainAvailread-onlycurrentDevice availability: 0 = Unavailable 1 = Available 2 = Partially Unavailable
1.3.6.1.4.1.21239.5.2.30.1.2TablevrcMainPtTablenot-accessiblecurrentTable that contains general VRC status
1.3.6.1.4.1.21239.5.2.30.1.2.1RowvrcMainPtEntrynot-accessiblecurrentEntry in the vrcMainPtTable: each entry contains status data for a VRC device
1.3.6.1.4.1.21239.5.2.30.1.2.1.1ColumnvrcMainPtIndexnot-accessiblecurrentUnique id for each entry in the table
1.3.6.1.4.1.21239.5.2.30.1.2.1.2ColumnvrcMainPtRunStateread-onlycurrentVRC run state: 1 = on 2 = off
1.3.6.1.4.1.21239.5.2.30.1.2.1.3ColumnvrcMainPtEevOpenedread-onlycurrentEev opened value (percent)
1.3.6.1.4.1.21239.5.2.30.1.2.1.4ColumnvrcMainPtAlarmNumbersread-onlycurrentAlarm numbers value
1.3.6.1.4.1.21239.5.2.30.1.2.1.5ColumnvrcMainPtHistoryAlarmNumbersread-onlycurrentHistory alarm numbers value
1.3.6.1.4.1.21239.5.2.30.1.2.1.6ColumnvrcMainPtHpAbnRecordCntread-onlycurrentHp Abnormal record count
1.3.6.1.4.1.21239.5.2.30.1.2.1.7ColumnvrcMainPtMonitorBaudrateread-onlycurrentMonitor baud rate: 1 = error 2 = 1200 3 = 2400 4 = 4800 5 = 9600 6 = 19200
1.3.6.1.4.1.21239.5.2.30.1.2.1.8ColumnvrcMainPtMonitorAddressread-onlycurrentMonitor address
1.3.6.1.4.1.21239.5.2.30.1.2.1.9ColumnvrcMainPtLpread-onlycurrentLp status
1.3.6.1.4.1.21239.5.2.30.1.2.1.10ColumnvrcMainPtFilterMaintRemindread-onlycurrentFilter maintenance reminder status
1.3.6.1.4.1.21239.5.2.30.1.2.1.11ColumnvrcMainPtCoolingFlagread-onlycurrentCooling flag
1.3.6.1.4.1.21239.5.2.30.1.2.1.12ColumnvrcMainPtFirstOnFlagread-onlycurrentFirst on flag
1.3.6.1.4.1.21239.5.2.30.1.2.1.13ColumnvrcMainPtNewAlarmFlagread-onlycurrentNew alarm flag
1.3.6.1.4.1.21239.5.2.30.1.2.1.14ColumnvrcMainPtComAlarmOutStateread-onlycurrentCommon alarm output state
1.3.6.1.4.1.21239.5.2.30.1.2.1.15ColumnvrcMainPtHighWaterInputread-onlycurrentHigh water input
1.3.6.1.4.1.21239.5.2.30.1.2.1.16ColumnvrcMainPtHighWaterAlarmread-onlycurrentHigh water alarm status
1.3.6.1.4.1.21239.5.2.30.1.2.1.17ColumnvrcMainPtWaterUnderFloorAlarmread-onlycurrentWater under floor alarm status
1.3.6.1.4.1.21239.5.2.30.1.2.1.18ColumnvrcMainPtSwShutDownStatusread-onlycurrentSoftware shutdown status
1.3.6.1.4.1.21239.5.2.30.1.2.1.19ColumnvrcMainPtRemoteShutdownread-onlycurrentRemote shutdown status
1.3.6.1.4.1.21239.5.2.30.1.2.1.20ColumnvrcMainPtRemoteShutDownFlagread-onlycurrentRemote shutdown flag
1.3.6.1.4.1.21239.5.2.30.1.2.1.21ColumnvrcMainPtRemoteShutDownAlarmread-onlycurrentRemote shutdown alarm status
1.3.6.1.4.1.21239.5.2.30.1.2.1.22ColumnvrcMainPtHmiShutDownFlagread-onlycurrentHmi shutdown flag
1.3.6.1.4.1.21239.5.2.30.1.2.1.23ColumnvrcMainPtLpAlarmread-onlycurrentLow pressure alarm status
1.3.6.1.4.1.21239.5.2.30.1.2.1.24ColumnvrcMainPtHpAlarmread-onlycurrentHigh pressure alarm status
1.3.6.1.4.1.21239.5.2.30.1.2.1.25ColumnvrcMainPtLpFreqAlarmread-onlycurrentLow pressure frequently alarm status
1.3.6.1.4.1.21239.5.2.30.1.2.1.26ColumnvrcMainPtHpFreqAlarmread-onlycurrentHigh pressure frequently alarm status
1.3.6.1.4.1.21239.5.2.30.1.2.1.27ColumnvrcMainPtLpSensorFailAlarmread-onlycurrentLow pressure sensor failure alarm status
1.3.6.1.4.1.21239.5.2.30.1.2.1.28ColumnvrcMainPtHpSensorFailAlarmread-onlycurrentHigh pressure sensor failure alarm status
1.3.6.1.4.1.21239.5.2.30.1.2.1.29ColumnvrcMainPtEevCommFailAlarmread-onlycurrentEev communication failure alarm status
1.3.6.1.4.1.21239.5.2.30.1.3TablevrcMainCfgTablenot-accessiblecurrentTable that contains general VRC configuration
1.3.6.1.4.1.21239.5.2.30.1.3.1RowvrcMainCfgEntrynot-accessiblecurrentEntry in the vrcMainCfgTable: each entry contains general config fields for a VRC device
1.3.6.1.4.1.21239.5.2.30.1.3.1.1ColumnvrcMainCfgIndexnot-accessiblecurrentUnique id for each entry in the table
1.3.6.1.4.1.21239.5.2.30.1.3.1.2ColumnvrcMainCfgModelSelectread-writecurrentModel Selection: 1 = TMM-Local 220V 50/60HZ 2 = TMM-Global 208/230V 50/60HZ 3 = TMM-Global 120V 50/60HZ 4 = SC 220V 50/60HZ 5 = 0U 220V 50/60HZ 6 = SS 208/230V…
1.3.6.1.4.1.21239.5.2.30.1.3.1.3ColumnvrcMainCfgSystemTimeYearread-writecurrentSystem time - year
1.3.6.1.4.1.21239.5.2.30.1.3.1.4ColumnvrcMainCfgSystemTimeMonthread-writecurrentSystem time - month
1.3.6.1.4.1.21239.5.2.30.1.3.1.5ColumnvrcMainCfgSystemTimeDayread-writecurrentSystem time - day
1.3.6.1.4.1.21239.5.2.30.1.3.1.6ColumnvrcMainCfgSystemTimeHourread-writecurrentSystem time - hour
1.3.6.1.4.1.21239.5.2.30.1.3.1.7ColumnvrcMainCfgSystemTimeMinread-writecurrentSystem time - minutes
1.3.6.1.4.1.21239.5.2.30.1.3.1.8ColumnvrcMainCfgSystemTimeSecread-writecurrentSystem time - seconds
1.3.6.1.4.1.21239.5.2.30.1.3.1.9ColumnvrcMainCfgEevShtSettingMinread-writecurrentMin Eev sht in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The settable range is determined by the current temperature units. …
1.3.6.1.4.1.21239.5.2.30.1.3.1.10ColumnvrcMainCfgEevShtSettingMaxread-writecurrentMax Eev sht in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The settable range is determined by the current temperature units. …
1.3.6.1.4.1.21239.5.2.30.1.3.1.11ColumnvrcMainCfgEevValveCloseShtread-writecurrentEev valve close sht in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The settable range is determined by the current temperature…
1.3.6.1.4.1.21239.5.2.30.1.3.1.12ColumnvrcMainCfgEevMopPressSettingread-writecurrentEev mop pressure setting in tenths of a bar.
1.3.6.1.4.1.21239.5.2.30.1.3.1.13ColumnvrcMainCfgLpdtread-writecurrentLow pressure dt in seconds
1.3.6.1.4.1.21239.5.2.30.1.3.1.14ColumnvrcMainCfgDeadBandread-writecurrentDead band in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The settable range is determined by the current temperature units. Ce…
1.3.6.1.4.1.21239.5.2.30.1.3.1.15ColumnvrcMainCfgOnOffSwitchread-writecurrentOn-off switch
1.3.6.1.4.1.21239.5.2.30.1.3.1.16ColumnvrcMainCfgVacuumStateread-writecurrentVacuum state
1.3.6.1.4.1.21239.5.2.30.1.3.1.17ColumnvrcMainCfgControlModeread-writecurrentControl mode: 1 = supply 2 = return
1.3.6.1.4.1.21239.5.2.30.1.3.1.18ColumnvrcMainCfgManualRunEnableread-writecurrentManual run enable
1.3.6.1.4.1.21239.5.2.30.1.3.1.19ColumnvrcMainCfgRemShutdownInputread-writecurrentRemote shutdown input
1.3.6.1.4.1.21239.5.2.30.1.3.1.20ColumnvrcMainCfgMonitorShutDownFlagread-writecurrentMonitor shutdown flag
1.3.6.1.4.1.21239.5.2.30.1.3.1.21ColumnvrcMainCfgFirstOnPasswordread-writecurrentFirst on password value
1.3.6.1.4.1.21239.5.2.30.1.3.1.22ColumnvrcMainCfgFilterMaintSettingread-writecurrentFilter maintenance setting
1.3.6.1.4.1.21239.5.2.30.1.3.1.23ColumnvrcMainCfgFilterMaintRemindTimeread-writecurrentTime between filter maintenance reminders in days
1.3.6.1.4.1.21239.5.2.30.1.3.1.24ColumnvrcMainCfgFilterMaintRemindCtrlread-writecurrentFilter maintenance reminder: 1 = close 2 = suspend 3 = open
1.3.6.1.4.1.21239.5.2.30.1.3.1.25ColumnvrcMainCfgCommonAlarmOutputDirread-writecurrentCommon alarm output direction
1.3.6.1.4.1.21239.5.2.30.1.3.1.26ColumnvrcMainCfgHpAbnAlarmSettingread-writecurrentAbnormal high pressure alarm value in tenths of a bar
1.3.6.1.4.1.21239.5.2.30.1.3.1.27ColumnvrcMainCfgLpAlarmCtrlread-writecurrentLow pressure alarm control: 2 = suspend 3 = open
1.3.6.1.4.1.21239.5.2.30.1.3.1.28ColumnvrcMainCfgHpAlarmCtrlread-writecurrentHigh pressure alarm control: 2 = suspend 3 = open
1.3.6.1.4.1.21239.5.2.30.1.3.1.29ColumnvrcMainCfgLpFreqAlarmCtrlread-writecurrentLow pressure frequently alarm control: 2 = suspend 3 = open
1.3.6.1.4.1.21239.5.2.30.1.3.1.30ColumnvrcMainCfgHpFreqAlarmCtrlread-writecurrentHigh pressure frequently alarm control: 2 = suspend 3 = open
1.3.6.1.4.1.21239.5.2.30.1.3.1.31ColumnvrcMainCfgLpSensorFailAlarmCtrlread-writecurrentLow pressure sensor failure alarm control: 2 = suspend 3 = open
1.3.6.1.4.1.21239.5.2.30.1.3.1.32ColumnvrcMainCfgHpSensorFailAlarmCtrlread-writecurrentHigh pressure sensor failure alarm control: 2 = suspend 3 = open
1.3.6.1.4.1.21239.5.2.30.1.3.1.33ColumnvrcMainCfgHighWaterAlarmCtrlread-writecurrentHigh water alarm control: 1 = close 2 = suspend 3 = open
1.3.6.1.4.1.21239.5.2.30.1.3.1.34ColumnvrcMainCfgRemShutdownAlarmCtrlread-writecurrentRemote shutdown alarm control: 2 = suspend 3 = open
1.3.6.1.4.1.21239.5.2.30.1.3.1.35ColumnvrcMainCfgEevCommFailAlarmCtrlread-writecurrentEev communication failure alarm: 2 = suspend 3 = open
1.3.6.1.4.1.21239.5.2.30.1.4TablevrcOutFanPtTablenot-accessiblecurrentTable that contains VRC out-fan status
1.3.6.1.4.1.21239.5.2.30.1.4.1RowvrcOutFanPtEntrynot-accessiblecurrentEntry in the vrcOutFanPtTable: each entry represents data for a VRC out-fan
1.3.6.1.4.1.21239.5.2.30.1.4.1.1ColumnvrcOutFanPtIndexnot-accessiblecurrentUnique id for each entry in the table
1.3.6.1.4.1.21239.5.2.30.1.4.1.2ColumnvrcOutFanPtNameread-onlycurrentOut-fan name (factory-assigned)
1.3.6.1.4.1.21239.5.2.30.1.4.1.3ColumnvrcOutFanPtSpeedread-onlycurrentFan speed (percent)
1.3.6.1.4.1.21239.5.2.30.1.5TablevrcOutFanCfgTablenot-accessiblecurrentTable used for VRC out-fan configuration
1.3.6.1.4.1.21239.5.2.30.1.5.1RowvrcOutFanCfgEntrynot-accessiblecurrentEntry in the vrcOutFanCfgTable: each entry contains config fields for a VRC out-fan
1.3.6.1.4.1.21239.5.2.30.1.5.1.1ColumnvrcOutFanCfgIndexnot-accessiblecurrentUnique id for each entry in the table
1.3.6.1.4.1.21239.5.2.30.1.5.1.2ColumnvrcOutFanCfgStartPressread-writecurrentOut-fan start pressure in tenths of a bar
1.3.6.1.4.1.21239.5.2.30.1.5.1.3ColumnvrcOutFanCfgPressSettingread-writecurrentOut-fan pressure setting in tenths of a bar
1.3.6.1.4.1.21239.5.2.30.1.5.1.4ColumnvrcOutFanCfgMinPowerVoltageread-writecurrentMin out-fan voltage (percent)
1.3.6.1.4.1.21239.5.2.30.1.5.1.5ColumnvrcOutFanCfgMaxPowerVoltageread-writecurrentMax out-fan voltage (percent)
1.3.6.1.4.1.21239.5.2.30.1.5.1.6ColumnvrcOutFanCfgSpeedread-writecurrentOut-fan speed (percent)
1.3.6.1.4.1.21239.5.2.30.1.6TablevrcInFanPtTablenot-accessiblecurrentTable that contains VRC in-fan status
1.3.6.1.4.1.21239.5.2.30.1.6.1RowvrcInFanPtEntrynot-accessiblecurrentEntry in the vrcInFanPtTable: each entry represents data for a VRC in- fan
1.3.6.1.4.1.21239.5.2.30.1.6.1.1ColumnvrcInFanPtIndexnot-accessiblecurrentUnique id for each entry in the table
1.3.6.1.4.1.21239.5.2.30.1.6.1.2ColumnvrcInFanPtNameread-onlycurrentIn-fan name (factory-assigned)
1.3.6.1.4.1.21239.5.2.30.1.6.1.3ColumnvrcInFanPtRunTimeHoursread-onlycurrentIn-fan run time in hours
1.3.6.1.4.1.21239.5.2.30.1.6.1.4ColumnvrcInFanPtStartStopCountread-onlycurrentIn-fan start/stop count
1.3.6.1.4.1.21239.5.2.30.1.7TablevrcInFanCfgTablenot-accessiblecurrentTable used for VRC in-fan configuration
1.3.6.1.4.1.21239.5.2.30.1.7.1RowvrcInFanCfgEntrynot-accessiblecurrentEntry in the vrcInFanCfgTable: each entry contains config fields for a VRC in-fan
1.3.6.1.4.1.21239.5.2.30.1.7.1.1ColumnvrcInFanCfgIndexnot-accessiblecurrentUnique id for each entry in the table
1.3.6.1.4.1.21239.5.2.30.1.7.1.2ColumnvrcInFanCfgOutputStatusread-writecurrentIn-fan output status
1.3.6.1.4.1.21239.5.2.30.1.7.1.3ColumnvrcInFanCfgLowSpeedStepread-writecurrentIn-fan low speed step in tenths of a percent per second
1.3.6.1.4.1.21239.5.2.30.1.7.1.4ColumnvrcInFanCfgHighSpeedStepread-writecurrentIn-fan high speed step in tenths of a percent per second
1.3.6.1.4.1.21239.5.2.30.1.7.1.5ColumnvrcInFanCfgMinSpeedread-writecurrentMin in-fan speed (percent)
1.3.6.1.4.1.21239.5.2.30.1.7.1.6ColumnvrcInFanCfgStandardSpeedread-writecurrentStandard in-fan speed (percent)
1.3.6.1.4.1.21239.5.2.30.1.7.1.7ColumnvrcInFanCfgMinCfcread-writecurrentMin in-fan cfc (percent)
1.3.6.1.4.1.21239.5.2.30.1.7.1.8ColumnvrcInFanCfgStandardCfcread-writecurrentStandard in-fan cfc (percent)
1.3.6.1.4.1.21239.5.2.30.1.7.1.9ColumnvrcInFanCfgStartDelayread-writecurrentIn-fan start delay in seconds
1.3.6.1.4.1.21239.5.2.30.1.7.1.10ColumnvrcInFanCfgStopDelayread-writecurrentIn-fan stop delay in seconds
1.3.6.1.4.1.21239.5.2.30.1.7.1.11ColumnvrcInFanCfgReduceSpeedDelayread-writecurrentIn-fan reduce speed delay in seconds
1.3.6.1.4.1.21239.5.2.30.1.7.1.12ColumnvrcInFanCfgJumpBand1read-writecurrentIn-fan jump band 1 in tenths of a percent
1.3.6.1.4.1.21239.5.2.30.1.7.1.13ColumnvrcInFanCfgJumpBand2read-writecurrentIn-fan jump band 2 in tenths of a percent
1.3.6.1.4.1.21239.5.2.30.1.7.1.14ColumnvrcInFanCfgJumpBand3read-writecurrentIn-fan jump band 3 in tenths of a percent
1.3.6.1.4.1.21239.5.2.30.1.7.1.15ColumnvrcInFanCfgJumpBand4read-writecurrentIn-fan jump band 4 in tenths of a percent
1.3.6.1.4.1.21239.5.2.30.1.7.1.16ColumnvrcInFanCfgJumpBand5read-writecurrentIn-fan jump band 5 in tenths of a percent
1.3.6.1.4.1.21239.5.2.30.1.7.1.17ColumnvrcInFanCfgJumpFreq1read-writecurrentIn-fan jump frequency 1 in tenths of a percent
1.3.6.1.4.1.21239.5.2.30.1.7.1.18ColumnvrcInFanCfgJumpFreq2read-writecurrentIn-fan jump frequency 2 in tenths of a percent
1.3.6.1.4.1.21239.5.2.30.1.7.1.19ColumnvrcInFanCfgJumpFreq3read-writecurrentIn-fan jump frequency 3 in tenths of a percent
1.3.6.1.4.1.21239.5.2.30.1.7.1.20ColumnvrcInFanCfgJumpFreq4read-writecurrentIn-fan jump frequency 4 in tenths of a percent
1.3.6.1.4.1.21239.5.2.30.1.7.1.21ColumnvrcInFanCfgJumpFreq5read-writecurrentIn-fan jump frequency 5 in tenths of a percent
1.3.6.1.4.1.21239.5.2.30.1.7.1.22ColumnvrcInFanCfgTempPread-writecurrentIn-fan temperature P in tenths of a degree. Units are given by temperatureUnits field in deviceInfo.
1.3.6.1.4.1.21239.5.2.30.1.7.1.23ColumnvrcInFanCfgTempIread-writecurrentIn-fan temperature I in seconds
1.3.6.1.4.1.21239.5.2.30.1.7.1.24ColumnvrcInFanCfgTempDread-writecurrentIn-fan temperature D in seconds
1.3.6.1.4.1.21239.5.2.30.1.8TablevrcCompPtTablenot-accessiblecurrentTable that contains VRC compressor status
1.3.6.1.4.1.21239.5.2.30.1.8.1RowvrcCompPtEntrynot-accessiblecurrentEntry in the vrcCompPtTable: each entry represents data for a VRC compressor
1.3.6.1.4.1.21239.5.2.30.1.8.1.1ColumnvrcCompPtIndexnot-accessiblecurrentUnique id for each entry in the table
1.3.6.1.4.1.21239.5.2.30.1.8.1.2ColumnvrcCompPtNameread-onlycurrentCompressor name (factory-assigned)
1.3.6.1.4.1.21239.5.2.30.1.8.1.3ColumnvrcCompPtCapacityread-onlycurrentCompressor capacity value (percent)
1.3.6.1.4.1.21239.5.2.30.1.8.1.4ColumnvrcCompPtRunTimeHoursread-onlycurrentCompressor run time in hours
1.3.6.1.4.1.21239.5.2.30.1.8.1.5ColumnvrcCompPtStartStopCountread-onlycurrentCompressor start/stop count
1.3.6.1.4.1.21239.5.2.30.1.8.1.6ColumnvrcCompPtDriverFaultU00read-onlycurrentCompressor driver fault alarm U00 state
1.3.6.1.4.1.21239.5.2.30.1.8.1.7ColumnvrcCompPtDriverFaultU01read-onlycurrentCompressor driver fault alarm U01 state
1.3.6.1.4.1.21239.5.2.30.1.8.1.8ColumnvrcCompPtDriverFaultU02read-onlycurrentCompressor driver fault alarm U02 state
1.3.6.1.4.1.21239.5.2.30.1.8.1.9ColumnvrcCompPtDriverFaultU03read-onlycurrentCompressor driver fault alarm U03 state
1.3.6.1.4.1.21239.5.2.30.1.8.1.10ColumnvrcCompPtDriverFaultU04read-onlycurrentCompressor driver fault alarm U04 state
1.3.6.1.4.1.21239.5.2.30.1.8.1.11ColumnvrcCompPtDriverFaultU05read-onlycurrentCompressor driver fault alarm U05 state
1.3.6.1.4.1.21239.5.2.30.1.8.1.12ColumnvrcCompPtDriverFaultU06read-onlycurrentCompressor driver fault alarm U06 state
1.3.6.1.4.1.21239.5.2.30.1.8.1.13ColumnvrcCompPtDriverFaultU07read-onlycurrentCompressor driver fault alarm U07 state
1.3.6.1.4.1.21239.5.2.30.1.8.1.14ColumnvrcCompPtDriverFaultU08read-onlycurrentCompressor driver fault alarm U08 state
1.3.6.1.4.1.21239.5.2.30.1.8.1.15ColumnvrcCompPtDriverFaultU09read-onlycurrentCompressor driver fault alarm U09 state
1.3.6.1.4.1.21239.5.2.30.1.8.1.16ColumnvrcCompPtDriverFaultU10read-onlycurrentCompressor driver fault alarm U10 state
1.3.6.1.4.1.21239.5.2.30.1.8.1.17ColumnvrcCompPtDriverFaultU11read-onlycurrentCompressor driver fault alarm U11 state
1.3.6.1.4.1.21239.5.2.30.1.8.1.18ColumnvrcCompPtDriverFaultU12read-onlycurrentCompressor driver fault alarm U12 state
1.3.6.1.4.1.21239.5.2.30.1.8.1.19ColumnvrcCompPtDriverFaultU13read-onlycurrentCompressor driver fault alarm U13 state
1.3.6.1.4.1.21239.5.2.30.1.8.1.20ColumnvrcCompPtDriverFaultU14read-onlycurrentCompressor driver fault alarm U14 state
1.3.6.1.4.1.21239.5.2.30.1.8.1.21ColumnvrcCompPtDriverFaultU15read-onlycurrentCompressor driver fault alarm U15 state
1.3.6.1.4.1.21239.5.2.30.1.8.1.22ColumnvrcCompPtDriverCommFailAlarmread-onlycurrentCompressor driver communication failure alarm state
1.3.6.1.4.1.21239.5.2.30.1.8.1.23ColumnvrcCompPtFaultLockAlarmread-onlycurrentCompressor fault lock alarm state
1.3.6.1.4.1.21239.5.2.30.1.9TablevrcCompCfgTablenot-accessiblecurrentTable used for VRC compressor configuration
1.3.6.1.4.1.21239.5.2.30.1.9.1RowvrcCompCfgEntrynot-accessiblecurrentEntry in the vrcCompCfgTable: each entry contains config fields for a VRC compressor
1.3.6.1.4.1.21239.5.2.30.1.9.1.1ColumnvrcCompCfgIndexnot-accessiblecurrentUnique id for each entry in the table
1.3.6.1.4.1.21239.5.2.30.1.9.1.2ColumnvrcCompCfgOutputStatusread-writecurrentCompressor output status
1.3.6.1.4.1.21239.5.2.30.1.9.1.3ColumnvrcCompCfgOutputDeadBandread-writecurrentCompressor output dead band in tenths of a percent
1.3.6.1.4.1.21239.5.2.30.1.9.1.4ColumnvrcCompCfgCapacityOutputValueread-writecurrentCompressor capacity output (percent)
1.3.6.1.4.1.21239.5.2.30.1.9.1.5ColumnvrcCompCfgMinCapacityread-writecurrentCompressor min capacity (percent)
1.3.6.1.4.1.21239.5.2.30.1.9.1.6ColumnvrcCompCfgStartCapacityread-writecurrentCompressor start capacity (percent)
1.3.6.1.4.1.21239.5.2.30.1.9.1.7ColumnvrcCompCfgStandardCapacityread-writecurrentCompressor standard capacity (percent)
1.3.6.1.4.1.21239.5.2.30.1.9.1.8ColumnvrcCompCfgStartCfcread-writecurrentCompressor start cfc (percent)
1.3.6.1.4.1.21239.5.2.30.1.9.1.9ColumnvrcCompCfgStopCfcread-writecurrentCompressor stop cfc (percent)
1.3.6.1.4.1.21239.5.2.30.1.9.1.10ColumnvrcCompCfgMinRunTimeread-writecurrentCompressor min run time in minutes
1.3.6.1.4.1.21239.5.2.30.1.9.1.11ColumnvrcCompCfgMinStopTimeread-writecurrentCompressor min stop time in minutes
1.3.6.1.4.1.21239.5.2.30.1.9.1.12ColumnvrcCompCfgJumpBand1read-writecurrentCompressor jump band 1 in tenths of a percent
1.3.6.1.4.1.21239.5.2.30.1.9.1.13ColumnvrcCompCfgJumpBand2read-writecurrentCompressor jump band 2 in tenths of a percent
1.3.6.1.4.1.21239.5.2.30.1.9.1.14ColumnvrcCompCfgJumpBand3read-writecurrentCompressor jump band 3 in tenths of a percent
1.3.6.1.4.1.21239.5.2.30.1.9.1.15ColumnvrcCompCfgJumpBand4read-writecurrentCompressor jump band 4 in tenths of a percent
1.3.6.1.4.1.21239.5.2.30.1.9.1.16ColumnvrcCompCfgJumpBand5read-writecurrentCompressor jump band 5 in tenths of a percent
1.3.6.1.4.1.21239.5.2.30.1.9.1.17ColumnvrcCompCfgJumpFreq1read-writecurrentCompressor jump frequency 1 in tenths of a percent
1.3.6.1.4.1.21239.5.2.30.1.9.1.18ColumnvrcCompCfgJumpFreq2read-writecurrentCompressor jump frequency 2 in tenths of a percent
1.3.6.1.4.1.21239.5.2.30.1.9.1.19ColumnvrcCompCfgJumpFreq3read-writecurrentCompressor jump frequency 3 in tenths of a percent
1.3.6.1.4.1.21239.5.2.30.1.9.1.20ColumnvrcCompCfgJumpFreq4read-writecurrentCompressor jump frequency 4 in tenths of a percent
1.3.6.1.4.1.21239.5.2.30.1.9.1.21ColumnvrcCompCfgJumpFreq5read-writecurrentCompressor jump frequency 5 in tenths of a percent
1.3.6.1.4.1.21239.5.2.30.1.9.1.22ColumnvrcCompCfgTempPread-writecurrentCompressor temperature P in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The settable range is determined by the current temper…
1.3.6.1.4.1.21239.5.2.30.1.9.1.23ColumnvrcCompCfgTempIread-writecurrentCompressor temperature I in seconds
1.3.6.1.4.1.21239.5.2.30.1.9.1.24ColumnvrcCompCfgTempDread-writecurrentCompressor temperature D in seconds
1.3.6.1.4.1.21239.5.2.30.1.9.1.25ColumnvrcCompCfgDriverFaultAlmCtrlread-writecurrentCompressor driver fault alarm control: 2 = suspend 3 = open
1.3.6.1.4.1.21239.5.2.30.1.9.1.26ColumnvrcCompCfgDriverCommFailAlmCtrlread-writecurrentCompressor driver communication failure alarm control: 2 = suspend 3 = open
1.3.6.1.4.1.21239.5.2.30.1.9.1.27ColumnvrcCompCfgFaultLockAlmCtrlread-writecurrentCompressor fault lock alarm control: 2 = suspend 3 = open
1.3.6.1.4.1.21239.5.2.30.1.10TablevrcReturnPtTablenot-accessiblecurrentTable that contains VRC return status
1.3.6.1.4.1.21239.5.2.30.1.10.1RowvrcReturnPtEntrynot-accessiblecurrentEntry in the vrcReturnPtTable: each entry represents return data for a VRC
1.3.6.1.4.1.21239.5.2.30.1.10.1.1ColumnvrcReturnPtIndexnot-accessiblecurrentUnique id for each entry in the table
1.3.6.1.4.1.21239.5.2.30.1.10.1.2ColumnvrcReturnPtNameread-onlycurrentReturn name (factory-assigned)
1.3.6.1.4.1.21239.5.2.30.1.10.1.3ColumnvrcReturnPtTempread-onlycurrentReturn temperature value in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The range is determined by the current temperature uni…
1.3.6.1.4.1.21239.5.2.30.1.10.1.4ColumnvrcReturnPtHighTempAlarmread-onlycurrentReturn high temperature alarm state
1.3.6.1.4.1.21239.5.2.30.1.10.1.5ColumnvrcReturnPtTempSensorFailAlarmread-onlycurrentReturn temperature sensor failure alarm state
1.3.6.1.4.1.21239.5.2.30.1.11TablevrcReturnCfgTablenot-accessiblecurrentTable used for VRC return configuration
1.3.6.1.4.1.21239.5.2.30.1.11.1RowvrcReturnCfgEntrynot-accessiblecurrentEntry in the vrcReturnCfgTable: each entry contains config fields for VRC return
1.3.6.1.4.1.21239.5.2.30.1.11.1.1ColumnvrcReturnCfgIndexnot-accessiblecurrentUnique id for each entry in the table
1.3.6.1.4.1.21239.5.2.30.1.11.1.2ColumnvrcReturnCfgOilCycleread-writecurrentReturn oil cycle in tenths of an hour
1.3.6.1.4.1.21239.5.2.30.1.11.1.3ColumnvrcReturnCfgOilRunCapacityread-writecurrentReturn Oil run capacity (percent)
1.3.6.1.4.1.21239.5.2.30.1.11.1.4ColumnvrcReturnCfgOilRunTimeread-writecurrentReturn oil run time in minutes
1.3.6.1.4.1.21239.5.2.30.1.11.1.5ColumnvrcReturnCfgTempCalValueread-writecurrentReturn temperature calibration value in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The settable range is determined by the cu…
1.3.6.1.4.1.21239.5.2.30.1.11.1.6ColumnvrcReturnCfgTempSettingread-writecurrentReturn temperature setting in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The settable range is determined by the current temp…
1.3.6.1.4.1.21239.5.2.30.1.11.1.7ColumnvrcReturnCfgHighTempAlarmValueread-writecurrentReturn high temperature alarm value in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The settable range is determined by the cur…
1.3.6.1.4.1.21239.5.2.30.1.11.1.8ColumnvrcReturnCfgHighTempAlarmCtrlread-writecurrentReturn high temperature alarm control: 1 = close 2 = suspend 3 = open
1.3.6.1.4.1.21239.5.2.30.1.11.1.9ColumnvrcReturnCfgTempSensFailAlmCtrlread-writecurrentReturn temperature sensor failure alarm control: 1 = close 2 = suspend 3 = open
1.3.6.1.4.1.21239.5.2.30.1.12TablevrcSupplyPtTablenot-accessiblecurrentTable that contains VRC supply status
1.3.6.1.4.1.21239.5.2.30.1.12.1RowvrcSupplyPtEntrynot-accessiblecurrentEntry in the vrcSupplyPtTable: each entry represents supply data for a VRC
1.3.6.1.4.1.21239.5.2.30.1.12.1.1ColumnvrcSupplyPtIndexnot-accessiblecurrentUnique id for each entry in the table
1.3.6.1.4.1.21239.5.2.30.1.12.1.2ColumnvrcSupplyPtNameread-onlycurrentSupply name (factory-assigned)
1.3.6.1.4.1.21239.5.2.30.1.12.1.3ColumnvrcSupplyPtTempread-onlycurrentSupply temperature value in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The range is determined by the current temperature uni…
1.3.6.1.4.1.21239.5.2.30.1.12.1.4ColumnvrcSupplyPtLowTempAlarmread-onlycurrentSupply low temperature alarm state
1.3.6.1.4.1.21239.5.2.30.1.12.1.5ColumnvrcSupplyPtHighTempAlarmread-onlycurrentSupply high temperature alarm state
1.3.6.1.4.1.21239.5.2.30.1.12.1.6ColumnvrcSupplyPtTempSensorFailAlarmread-onlycurrentSupply temperature sensor failure alarm state
1.3.6.1.4.1.21239.5.2.30.1.13TablevrcSupplyCfgTablenot-accessiblecurrentTable used for VRC supply configuration
1.3.6.1.4.1.21239.5.2.30.1.13.1RowvrcSupplyCfgEntrynot-accessiblecurrentEntry in the vrcSupplyCfgTable: each entry contains config fields for a VRC supply
1.3.6.1.4.1.21239.5.2.30.1.13.1.1ColumnvrcSupplyCfgIndexnot-accessiblecurrentUnique id for each entry in the table
1.3.6.1.4.1.21239.5.2.30.1.13.1.2ColumnvrcSupplyCfgTempCalValueread-writecurrentSupply temperature calibration value in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The settable range is determined by the cu…
1.3.6.1.4.1.21239.5.2.30.1.13.1.3ColumnvrcSupplyCfgTempSettingread-writecurrentSupply temperature setting in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The settable range is determined by the current temp…
1.3.6.1.4.1.21239.5.2.30.1.13.1.4ColumnvrcSupplyCfgLowTempAlarmValueread-writecurrentSupply low temperature alarm value in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The settable range is determined by the curr…
1.3.6.1.4.1.21239.5.2.30.1.13.1.5ColumnvrcSupplyCfgHighTempAlarmValueread-writecurrentSupply high temperature alarm value in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The settable range is determined by the cur…
1.3.6.1.4.1.21239.5.2.30.1.13.1.6ColumnvrcSupplyCfgLowTempAlmCtrlread-writecurrentSupply low temperature alarm control: 1 = close 2 = suspend 3 = open
1.3.6.1.4.1.21239.5.2.30.1.13.1.7ColumnvrcSupplyCfgHighTempAlmCtrlread-writecurrentSupply high temperature alarm control: 1 = close 2 = suspend 3 = open
1.3.6.1.4.1.21239.5.2.30.1.13.1.8ColumnvrcSupplyCfgTempSensFailAlmCtrlread-writecurrentSupply temperature sensor failure alarm control: 1 = close 2 = suspend 3 = open
1.3.6.1.4.1.21239.5.2.30.1.14TablevrcPowerPtTablenot-accessiblecurrentTable that contains VRC power status
1.3.6.1.4.1.21239.5.2.30.1.14.1RowvrcPowerPtEntrynot-accessiblecurrentEntry in the vrcPowerPtTable: each entry represents power data for a VRC
1.3.6.1.4.1.21239.5.2.30.1.14.1.1ColumnvrcPowerPtIndexnot-accessiblecurrentUnique id for each entry in the table
1.3.6.1.4.1.21239.5.2.30.1.14.1.2ColumnvrcPowerPtNameread-onlycurrentPower name (factory-assigned)
1.3.6.1.4.1.21239.5.2.30.1.14.1.3ColumnvrcPowerPtVoltageread-onlycurrentPower voltage measurement in tenths of a volt
1.3.6.1.4.1.21239.5.2.30.1.14.1.4ColumnvrcPowerPtFrequencyread-onlycurrentPower frequency measurement in tenths of hertz
1.3.6.1.4.1.21239.5.2.30.1.14.1.5ColumnvrcPowerPtLowVoltageAlarmread-onlycurrentPower low voltage alarm state
1.3.6.1.4.1.21239.5.2.30.1.14.1.6ColumnvrcPowerPtHighVoltageAlarmread-onlycurrentPower high voltage alarm state
1.3.6.1.4.1.21239.5.2.30.1.14.1.7ColumnvrcPowerPtLossOfPhasePowerAlarmread-onlycurrentPhase power loss alarm state
1.3.6.1.4.1.21239.5.2.30.1.14.1.8ColumnvrcPowerPtLossOfPowerAlarmread-onlycurrentPower loss alarm state
1.3.6.1.4.1.21239.5.2.30.1.14.1.9ColumnvrcPowerPtFrequencyErrorAlarmread-onlycurrentPower frequency error alarm state
1.3.6.1.4.1.21239.5.2.30.1.15TablevrcPowerCfgTablenot-accessiblecurrentTable used for VRC power configuration
1.3.6.1.4.1.21239.5.2.30.1.15.1RowvrcPowerCfgEntrynot-accessiblecurrentEntry in the vrcPowerCfgTable: each entry contains config fields for VRC power
1.3.6.1.4.1.21239.5.2.30.1.15.1.1ColumnvrcPowerCfgIndexnot-accessiblecurrentUnique id for each entry in the table
1.3.6.1.4.1.21239.5.2.30.1.15.1.2ColumnvrcPowerCfgLowVoltageSettingread-writecurrentPower low voltage setting in volts
1.3.6.1.4.1.21239.5.2.30.1.15.1.3ColumnvrcPowerCfgHighVoltageSettingread-writecurrentPower high voltage setting in volts
1.3.6.1.4.1.21239.5.2.30.1.15.1.4ColumnvrcPowerCfgLowVoltageAlarmCtrlread-writecurrentPower low voltage alarm control: 1 = close 2 = suspend 3 = open
1.3.6.1.4.1.21239.5.2.30.1.15.1.5ColumnvrcPowerCfgHighVoltageAlarmCtrlread-writecurrentPower high voltage alarm control: 1 = close 2 = suspend 3 = open
1.3.6.1.4.1.21239.5.2.30.1.15.1.6ColumnvrcPowerCfgLossOfPowerAlarmCtrlread-writecurrentPower loss alarm control: 1 = close 2 = suspend 3 = open
1.3.6.1.4.1.21239.5.2.30.1.15.1.7ColumnvrcPowerCfgFreqErrorAlarmCtrlread-writecurrentPower frequency error alarm control: 1 = close 2 = suspend 3 = open
1.3.6.1.4.1.21239.5.2.30.1.16TablevrcOutdoorPtTablenot-accessiblecurrentTable that contains VRC outdoor status
1.3.6.1.4.1.21239.5.2.30.1.16.1RowvrcOutdoorPtEntrynot-accessiblecurrentEntry in the vrcOutdoorPtTable: each entry represents data for a VRC outdoor
1.3.6.1.4.1.21239.5.2.30.1.16.1.1ColumnvrcOutdoorPtIndexnot-accessiblecurrentUnique id for each entry in the table
1.3.6.1.4.1.21239.5.2.30.1.16.1.2ColumnvrcOutdoorPtNameread-onlycurrentOutdoor name (factory-assigned)
1.3.6.1.4.1.21239.5.2.30.1.16.1.3ColumnvrcOutdoorPtTempread-onlycurrentOutdoor temperature value in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The range is determined by the current temperature un…
1.3.6.1.4.1.21239.5.2.30.1.18TablevrcDischPtTablenot-accessiblecurrentTable that contains VRC discharge status
1.3.6.1.4.1.21239.5.2.30.1.18.1RowvrcDischPtEntrynot-accessiblecurrentEntry in the vrcDischPtTable: each entry represents discharge data for a VRC
1.3.6.1.4.1.21239.5.2.30.1.18.1.1ColumnvrcDischPtIndexnot-accessiblecurrentUnique id for each entry in the table
1.3.6.1.4.1.21239.5.2.30.1.18.1.2ColumnvrcDischPtNameread-onlycurrentDischarge name (factory-assigned)
1.3.6.1.4.1.21239.5.2.30.1.18.1.3ColumnvrcDischPtTempread-writecurrentDischarge temperature value in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The range is determined by the current temperature …
1.3.6.1.4.1.21239.5.2.30.1.18.1.4ColumnvrcDischPtPressureread-writecurrentDischarge air pressure value in tenths of a bar
1.3.6.1.4.1.21239.5.2.30.1.18.1.5ColumnvrcDischPtHighTempAlarmread-onlycurrentDischarge high temperature alarm state
1.3.6.1.4.1.21239.5.2.30.1.18.1.6ColumnvrcDischPtHighTempFreqAlarmread-onlycurrentDischarge high temperature frequently alarm state
1.3.6.1.4.1.21239.5.2.30.1.18.1.7ColumnvrcDischPtTempSensorFailAlarmread-onlycurrentDischarge temperature sensor failure alarm state
1.3.6.1.4.1.21239.5.2.30.1.19TablevrcDischCfgTablenot-accessiblecurrentTable used for VRC discharge configuration
1.3.6.1.4.1.21239.5.2.30.1.19.1RowvrcDischCfgEntrynot-accessiblecurrentEntry in the vrcDischCfgTable: each entry contains config fields for VRC discharge
1.3.6.1.4.1.21239.5.2.30.1.19.1.1ColumnvrcDischCfgIndexnot-accessiblecurrentUnique id for each entry in the table
1.3.6.1.4.1.21239.5.2.30.1.19.1.2ColumnvrcDischCfgTempCalValueread-writecurrentDischarge temperature calibration value in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The settable range is determined by the…
1.3.6.1.4.1.21239.5.2.30.1.19.1.3ColumnvrcDischCfgPressCalValueread-writecurrentDischarge pressure calibration value in tenths of a bar
1.3.6.1.4.1.21239.5.2.30.1.19.1.4ColumnvrcDischCfgHighTempAlmCtrlread-writecurrentDischarge high temperature alarm control: 2 = suspend 3 = open
1.3.6.1.4.1.21239.5.2.30.1.19.1.5ColumnvrcDischCfgHighTempFreqAlmCtrlread-writecurrentDischarge high temperature frequenctly alarm control: 2 = suspend 3 = open
1.3.6.1.4.1.21239.5.2.30.1.19.1.6ColumnvrcDischCfgTempSensFailAlmCtrlread-writecurrentDischarge temperature sensor failure alarm control: 2 = suspend 3 = open
1.3.6.1.4.1.21239.5.2.30.1.20TablevrcSuctPtTablenot-accessiblecurrentTable that contains VRC suction status
1.3.6.1.4.1.21239.5.2.30.1.20.1RowvrcSuctPtEntrynot-accessiblecurrentEntry in the vrcSuctPtTable: each entry represents suction data for a VRC
1.3.6.1.4.1.21239.5.2.30.1.20.1.1ColumnvrcSuctPtIndexnot-accessiblecurrentUnique id for each entry in the table
1.3.6.1.4.1.21239.5.2.30.1.20.1.2ColumnvrcSuctPtNameread-onlycurrentSuction name (factory-assigned)
1.3.6.1.4.1.21239.5.2.30.1.20.1.3ColumnvrcSuctPtTempread-onlycurrentSuction temperature in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The range is determined by the current temperature units. C…
1.3.6.1.4.1.21239.5.2.30.1.20.1.4ColumnvrcSuctPtPressureread-onlycurrentSuction air pressure in tenths of a bar
1.3.6.1.4.1.21239.5.2.30.1.20.1.5ColumnvrcSuctPtSuperHeatTempread-onlycurrentSuction super heat temperature in tenths of a degree. Units are given by temperatureUnits field in deviceInfo. The range is determined by the current temperatu…
1.3.6.1.4.1.21239.5.2.30.1.20.1.6ColumnvrcSuctPtTempSensorFailAlarmread-onlycurrentSuction temperature sensor failure alarm state
1.3.6.1.4.1.21239.5.2.30.1.21TablevrcSuctCfgTablenot-accessiblecurrentTable used for VRC suction configuration
1.3.6.1.4.1.21239.5.2.30.1.21.1RowvrcSuctCfgEntrynot-accessiblecurrentEntry in the vrcSuctCfgTable: each entry contains config fields for VRC suction
1.3.6.1.4.1.21239.5.2.30.1.21.1.1ColumnvrcSuctCfgIndexnot-accessiblecurrentUnique id for each entry in the table
1.3.6.1.4.1.21239.5.2.30.1.21.1.2ColumnvrcSuctCfgPressCalValueread-writecurrentSuction pressure calibration value in tenths of a bar
1.3.6.1.4.1.21239.5.2.30.1.21.1.3ColumnvrcSuctCfgTempSensFailAlmCtrlread-writecurrentSuction temperature sensor failure alarm control: 2 = suspend 3 = open
1.3.6.1.4.1.21239.5.2.32767Nodetrap
1.3.6.1.4.1.21239.5.2.32767.0NodetrapPrefix
1.3.6.1.4.1.21239.5.2.32767.0.10101NotificationinternalTestNOTIFYcurrentTest SNMP Trap
1.3.6.1.4.1.21239.5.2.32767.0.10305NotificationpduMainAvailNOTIFYcurrentPDU availability trap
1.3.6.1.4.1.21239.5.2.32767.0.10309NotificationpduTotalRealPowerNOTIFYcurrentPDU total real power trap
1.3.6.1.4.1.21239.5.2.32767.0.10310NotificationpduTotalApparentPowerNOTIFYcurrentPDU total apparent power trap
1.3.6.1.4.1.21239.5.2.32767.0.10311NotificationpduTotalPowerFactorNOTIFYcurrentPDU total power factor trap
1.3.6.1.4.1.21239.5.2.32767.0.10312NotificationpduTotalEnergyNOTIFYcurrentPDU total energy trap
1.3.6.1.4.1.21239.5.2.32767.0.10324NotificationpduPhaseVoltageNOTIFYcurrentPDU phase voltage trap
1.3.6.1.4.1.21239.5.2.32767.0.10328NotificationpduPhaseCurrentNOTIFYcurrentPDU phase current trap
1.3.6.1.4.1.21239.5.2.32767.0.10332NotificationpduPhaseRealPowerNOTIFYcurrentPDU phase real power trap
1.3.6.1.4.1.21239.5.2.32767.0.10333NotificationpduPhaseApparentPowerNOTIFYcurrentPDU phase apparent power trap
1.3.6.1.4.1.21239.5.2.32767.0.10334NotificationpduPhasePowerFactorNOTIFYcurrentPDU phase power factor trap
1.3.6.1.4.1.21239.5.2.32767.0.10335NotificationpduPhaseEnergyNOTIFYcurrentPDU phase energy trap
1.3.6.1.4.1.21239.5.2.32767.0.10337NotificationpduPhaseBalanceNOTIFYcurrentPDU phase balance trap
1.3.6.1.4.1.21239.5.2.32767.0.10339NotificationpduPhaseCurrentCrestFactorNOTIFYcurrentPDU phase current crest factor trap
1.3.6.1.4.1.21239.5.2.32767.0.10354NotificationpduBreakerCurrentNOTIFYcurrentPDU breaker current trap
1.3.6.1.4.1.21239.5.2.32767.0.10358NotificationpduBreakerVoltageNOTIFYcurrentPDU breaker voltage trap
1.3.6.1.4.1.21239.5.2.32767.0.10362NotificationpduBreakerRealPowerNOTIFYcurrentPDU breaker real power trap
1.3.6.1.4.1.21239.5.2.32767.0.10363NotificationpduBreakerApparentPowerNOTIFYcurrentPDU breaker apparent power trap
1.3.6.1.4.1.21239.5.2.32767.0.10364NotificationpduBreakerPowerFactorNOTIFYcurrentPDU breaker power factor trap
1.3.6.1.4.1.21239.5.2.32767.0.10365NotificationpduBreakerEnergyNOTIFYcurrentPDU breaker energy trap
1.3.6.1.4.1.21239.5.2.32767.0.10374NotificationpduLineCurrentNOTIFYcurrentPDU line current trap
1.3.6.1.4.1.21239.5.2.32767.0.10385NotificationpduOutletMeterVoltageNOTIFYcurrentPDU outlet voltage trap
1.3.6.1.4.1.21239.5.2.32767.0.10389NotificationpduOutletMeterCurrentNOTIFYcurrentPDU outlet current trap
1.3.6.1.4.1.21239.5.2.32767.0.10393NotificationpduOutletMeterRealPowerNOTIFYcurrentPDU outlet real power trap
1.3.6.1.4.1.21239.5.2.32767.0.10394NotificationpduOutletMeterApparentPowerNOTIFYcurrentPDU outlet apparent power trap
1.3.6.1.4.1.21239.5.2.32767.0.10395NotificationpduOutletMeterPowerFactorNOTIFYcurrentPDU outlet power factor trap
1.3.6.1.4.1.21239.5.2.32767.0.10396NotificationpduOutletMeterEnergyNOTIFYcurrentPDU outlet energy trap
1.3.6.1.4.1.21239.5.2.32767.0.10400NotificationpduOutletCurrentCrestFactorNOTIFYcurrentPDU outlet current crest factor trap
1.3.6.1.4.1.21239.5.2.32767.0.10404NotificationtempSensorAvailNOTIFYcurrentRT availability trap
1.3.6.1.4.1.21239.5.2.32767.0.10405NotificationtempSensorTempNOTIFYcurrentRT temperature trap
1.3.6.1.4.1.21239.5.2.32767.0.10504NotificationairFlowSensorAvailNOTIFYcurrentAFHT3 availability trap
1.3.6.1.4.1.21239.5.2.32767.0.10505NotificationairFlowSensorTempNOTIFYcurrentAFHT3 temperature trap
1.3.6.1.4.1.21239.5.2.32767.0.10506NotificationairFlowSensorFlowNOTIFYcurrentAFHT3 airflow trap
1.3.6.1.4.1.21239.5.2.32767.0.10507NotificationairFlowSensorHumidityNOTIFYcurrentAFHT3 humidity trap
1.3.6.1.4.1.21239.5.2.32767.0.10508NotificationairFlowSensorDewPointNOTIFYcurrentAFHT3 dewpoint trap
1.3.6.1.4.1.21239.5.2.32767.0.10804Notificationt3hdSensorAvailNOTIFYcurrentT3HD availability trap
1.3.6.1.4.1.21239.5.2.32767.0.10806Notificationt3hdSensorIntTempNOTIFYcurrentT3HD Internal temperature trap
1.3.6.1.4.1.21239.5.2.32767.0.10807Notificationt3hdSensorIntHumidityNOTIFYcurrentT3HD Internal humidity trap
1.3.6.1.4.1.21239.5.2.32767.0.10808Notificationt3hdSensorIntDewPointNOTIFYcurrentT3HD Internal dewpoint trap
1.3.6.1.4.1.21239.5.2.32767.0.10811Notificationt3hdSensorExtATempNOTIFYcurrentT3HD External A temperature trap
1.3.6.1.4.1.21239.5.2.32767.0.10814Notificationt3hdSensorExtBTempNOTIFYcurrentT3HD External B temperature trap
1.3.6.1.4.1.21239.5.2.32767.0.10904NotificationthdSensorAvailNOTIFYcurrentTHD availability trap
1.3.6.1.4.1.21239.5.2.32767.0.10905NotificationthdSensorTempNOTIFYcurrentTHD temperature trap
1.3.6.1.4.1.21239.5.2.32767.0.10906NotificationthdSensorHumidityNOTIFYcurrentTHD humidity trap
1.3.6.1.4.1.21239.5.2.32767.0.10907NotificationthdSensorDewPointNOTIFYcurrentTHD dewpoint trap
1.3.6.1.4.1.21239.5.2.32767.0.11104Notificationa2dSensorAvailNOTIFYcurrentA2D availability trap
1.3.6.1.4.1.21239.5.2.32767.0.11105Notificationa2dSensorValueNOTIFYcurrentA2D measurement trap
1.3.6.1.4.1.21239.5.2.32767.0.11204NotificationhumiditySensorAvailNOTIFYcurrentRemote humidity availability trap
1.3.6.1.4.1.21239.5.2.32767.0.11205NotificationhumiditySensorValueNOTIFYcurrentRemote humidity value trap
1.3.6.1.4.1.21239.5.2.32767.0.11304Notificationsn2dSensorAvailNOTIFYcurrentSN-2D availability trap
1.3.6.1.4.1.21239.5.2.32767.0.11306Notificationsn2dSensorDoor1StateNOTIFYcurrentSN-2D Door switch 1 state trap
1.3.6.1.4.1.21239.5.2.32767.0.11309Notificationsn2dSensorDoor2StateNOTIFYcurrentSN-2D Door switch 2 state trap
1.3.6.1.4.1.21239.5.2.32767.0.12004NotificationpduResidualCurrentAggregateNOTIFYcurrentPDU residual current aggregate trap
1.3.6.1.4.1.21239.5.2.32767.0.12005NotificationpduResidualCurrentDcNOTIFYcurrentPDU residual current DC trap
1.3.6.1.4.1.21239.5.2.32767.0.13001NotificationvrcMainAvailNOTIFYcurrentVRC availability trap
1.3.6.1.4.1.21239.5.2.32767.0.13002NotificationvrcOutFanPtSpeedNOTIFYcurrentVRC out-fan speed trap
1.3.6.1.4.1.21239.5.2.32767.0.13003NotificationvrcCompPtCapacityNOTIFYcurrentVRC compressor capacity trap
1.3.6.1.4.1.21239.5.2.32767.0.13004NotificationvrcReturnPtTempNOTIFYcurrentVRC return temperature trap
1.3.6.1.4.1.21239.5.2.32767.0.13005NotificationvrcSupplyPtTempNOTIFYcurrentVRC supply temperature trap
1.3.6.1.4.1.21239.5.2.32767.0.13006NotificationvrcPowerPtVoltageNOTIFYcurrentVRC power voltage trap
1.3.6.1.4.1.21239.5.2.32767.0.13007NotificationvrcPowerPtFrequencyNOTIFYcurrentVRC power frequency trap
1.3.6.1.4.1.21239.5.2.32767.0.13008NotificationvrcOutdoorPtTempNOTIFYcurrentVRC outdoor temperature trap
1.3.6.1.4.1.21239.5.2.32767.0.13009NotificationvrcDischPtTempNOTIFYcurrentVRC discharge temperature trap
1.3.6.1.4.1.21239.5.2.32767.0.13010NotificationvrcDischPtPressureNOTIFYcurrentVRC discharge pressure trap
1.3.6.1.4.1.21239.5.2.32767.0.13011NotificationvrcSuctPtTempNOTIFYcurrentVRC suction temperature trap
1.3.6.1.4.1.21239.5.2.32767.0.13012NotificationvrcSuctPtPressureNOTIFYcurrentVRC suction pressure trap
1.3.6.1.4.1.21239.5.2.32767.0.20305NotificationpduMainAvailCLEARcurrentPDU availability clear trap
1.3.6.1.4.1.21239.5.2.32767.0.20309NotificationpduTotalRealPowerCLEARcurrentPDU total real power clear trap
1.3.6.1.4.1.21239.5.2.32767.0.20310NotificationpduTotalApparentPowerCLEARcurrentPDU total apparent power clear trap
1.3.6.1.4.1.21239.5.2.32767.0.20311NotificationpduTotalPowerFactorCLEARcurrentPDU total power factor clear trap
1.3.6.1.4.1.21239.5.2.32767.0.20312NotificationpduTotalEnergyCLEARcurrentPDU total energy clear trap
1.3.6.1.4.1.21239.5.2.32767.0.20324NotificationpduPhaseVoltageCLEARcurrentPDU phase voltage clear trap
1.3.6.1.4.1.21239.5.2.32767.0.20328NotificationpduPhaseCurrentCLEARcurrentPDU phase current clear trap
1.3.6.1.4.1.21239.5.2.32767.0.20332NotificationpduPhaseRealPowerCLEARcurrentPDU phase real power clear trap
1.3.6.1.4.1.21239.5.2.32767.0.20333NotificationpduPhaseApparentPowerCLEARcurrentPDU phase apparent power clear trap
1.3.6.1.4.1.21239.5.2.32767.0.20334NotificationpduPhasePowerFactorCLEARcurrentPDU phase power factor clear trap
1.3.6.1.4.1.21239.5.2.32767.0.20335NotificationpduPhaseEnergyCLEARcurrentPDU phase energy clear trap
1.3.6.1.4.1.21239.5.2.32767.0.20337NotificationpduPhaseBalanceCLEARcurrentPDU phase balance clear trap
1.3.6.1.4.1.21239.5.2.32767.0.20339NotificationpduPhaseCurrentCrestFactorCLEARcurrentPDU phase current crest factor clear trap
1.3.6.1.4.1.21239.5.2.32767.0.20354NotificationpduBreakerCurrentCLEARcurrentPDU breaker current clear trap
1.3.6.1.4.1.21239.5.2.32767.0.20358NotificationpduBreakerVoltageCLEARcurrentPDU breaker voltage clear trap
1.3.6.1.4.1.21239.5.2.32767.0.20362NotificationpduBreakerRealPowerCLEARcurrentPDU breaker real power clear trap
1.3.6.1.4.1.21239.5.2.32767.0.20363NotificationpduBreakerApparentPowerCLEARcurrentPDU breaker apparent power clear trap
1.3.6.1.4.1.21239.5.2.32767.0.20364NotificationpduBreakerPowerFactorCLEARcurrentPDU breaker power factor clear trap
1.3.6.1.4.1.21239.5.2.32767.0.20365NotificationpduBreakerEnergyCLEARcurrentPDU breaker energy clear trap
1.3.6.1.4.1.21239.5.2.32767.0.20374NotificationpduLineCurrentCLEARcurrentPDU line current clear trap
1.3.6.1.4.1.21239.5.2.32767.0.20385NotificationpduOutletMeterVoltageCLEARcurrentPDU outlet voltage clear trap
1.3.6.1.4.1.21239.5.2.32767.0.20389NotificationpduOutletMeterCurrentCLEARcurrentPDU outlet current clear trap
1.3.6.1.4.1.21239.5.2.32767.0.20393NotificationpduOutletMeterRealPowerCLEARcurrentPDU outlet real power clear trap
1.3.6.1.4.1.21239.5.2.32767.0.20394NotificationpduOutletMeterApparentPowerCLEARcurrentPDU outlet apparent power clear trap
1.3.6.1.4.1.21239.5.2.32767.0.20395NotificationpduOutletMeterPowerFactorCLEARcurrentPDU outlet power factor clear trap
1.3.6.1.4.1.21239.5.2.32767.0.20396NotificationpduOutletMeterEnergyCLEARcurrentPDU outlet energy clear trap
1.3.6.1.4.1.21239.5.2.32767.0.20400NotificationpduOutletCurrentCrestFactorCLEARcurrentPDU outlet current crest factor clear trap
1.3.6.1.4.1.21239.5.2.32767.0.20404NotificationtempSensorAvailCLEARcurrentRT availability clear trap
1.3.6.1.4.1.21239.5.2.32767.0.20405NotificationtempSensorTempCLEARcurrentRT temperature clear trap
1.3.6.1.4.1.21239.5.2.32767.0.20504NotificationairFlowSensorAvailCLEARcurrentAFHT3 availability clear trap
1.3.6.1.4.1.21239.5.2.32767.0.20505NotificationairFlowSensorTempCLEARcurrentAFHT3 temperature clear trap
1.3.6.1.4.1.21239.5.2.32767.0.20506NotificationairFlowSensorFlowCLEARcurrentAFHT3 airflow clear trap
1.3.6.1.4.1.21239.5.2.32767.0.20507NotificationairFlowSensorHumidityCLEARcurrentAFHT3 humidity clear trap
1.3.6.1.4.1.21239.5.2.32767.0.20508NotificationairFlowSensorDewPointCLEARcurrentAFHT3 dewpoint clear trap
1.3.6.1.4.1.21239.5.2.32767.0.20804Notificationt3hdSensorAvailCLEARcurrentT3HD availability clear trap
1.3.6.1.4.1.21239.5.2.32767.0.20806Notificationt3hdSensorIntTempCLEARcurrentT3HD Internal temperature clear trap
1.3.6.1.4.1.21239.5.2.32767.0.20807Notificationt3hdSensorIntHumidityCLEARcurrentT3HD Internal humidity clear trap
1.3.6.1.4.1.21239.5.2.32767.0.20808Notificationt3hdSensorIntDewPointCLEARcurrentT3HD Internal dewpoint clear trap
1.3.6.1.4.1.21239.5.2.32767.0.20811Notificationt3hdSensorExtATempCLEARcurrentT3HD External A temperature clear trap
1.3.6.1.4.1.21239.5.2.32767.0.20814Notificationt3hdSensorExtBTempCLEARcurrentT3HD External B temperature clear trap
1.3.6.1.4.1.21239.5.2.32767.0.20904NotificationthdSensorAvailCLEARcurrentTHD availability clear trap
1.3.6.1.4.1.21239.5.2.32767.0.20905NotificationthdSensorTempCLEARcurrentTHD temperature clear trap
1.3.6.1.4.1.21239.5.2.32767.0.20906NotificationthdSensorHumidityCLEARcurrentTHD humidity clear trap
1.3.6.1.4.1.21239.5.2.32767.0.20907NotificationthdSensorDewPointCLEARcurrentTHD dewpoint clear trap
1.3.6.1.4.1.21239.5.2.32767.0.21104Notificationa2dSensorAvailCLEARcurrentA2D availability clear trap
1.3.6.1.4.1.21239.5.2.32767.0.21105Notificationa2dSensorValueCLEARcurrentA2D measurement clear trap
1.3.6.1.4.1.21239.5.2.32767.0.21204NotificationhumiditySensorAvailCLEARcurrentRemote humidity availability clear trap
1.3.6.1.4.1.21239.5.2.32767.0.21205NotificationhumiditySensorValueCLEARcurrentRemote humidity value clear trap
1.3.6.1.4.1.21239.5.2.32767.0.21304Notificationsn2dSensorAvailCLEARcurrentSN-2D availability clear trap
1.3.6.1.4.1.21239.5.2.32767.0.21306Notificationsn2dSensorDoor1StateCLEARcurrentSN-2D Door switch 1 state clear trap
1.3.6.1.4.1.21239.5.2.32767.0.21309Notificationsn2dSensorDoor2StateCLEARcurrentSN-2D Door switch 2 state clear trap
1.3.6.1.4.1.21239.5.2.32767.0.22004NotificationpduResidualCurrentAggregateCLEARcurrentPDU residual current aggregate clear trap
1.3.6.1.4.1.21239.5.2.32767.0.22005NotificationpduResidualCurrentDcCLEARcurrentPDU residual current DC clear trap
1.3.6.1.4.1.21239.5.2.32767.0.23001NotificationvrcMainAvailCLEARcurrentVRC availability clear trap
1.3.6.1.4.1.21239.5.2.32767.0.23002NotificationvrcOutFanPtSpeedCLEARcurrentVRC out-fan speed clear trap
1.3.6.1.4.1.21239.5.2.32767.0.23003NotificationvrcCompPtCapacityCLEARcurrentVRC compressor capacity clear trap
1.3.6.1.4.1.21239.5.2.32767.0.23004NotificationvrcReturnPtTempCLEARcurrentVRC return temperature clear trap
1.3.6.1.4.1.21239.5.2.32767.0.23005NotificationvrcSupplyPtTempCLEARcurrentVRC supply temperature clear trap
1.3.6.1.4.1.21239.5.2.32767.0.23006NotificationvrcPowerPtVoltageCLEARcurrentVRC power voltage clear trap
1.3.6.1.4.1.21239.5.2.32767.0.23007NotificationvrcPowerPtFrequencyCLEARcurrentVRC power frequency clear trap
1.3.6.1.4.1.21239.5.2.32767.0.23008NotificationvrcOutdoorPtTempCLEARcurrentVRC outdoor temperature clear trap
1.3.6.1.4.1.21239.5.2.32767.0.23009NotificationvrcDischPtTempCLEARcurrentVRC discharge temperature clear trap
1.3.6.1.4.1.21239.5.2.32767.0.23010NotificationvrcDischPtPressureCLEARcurrentVRC discharge pressure clear trap
1.3.6.1.4.1.21239.5.2.32767.0.23011NotificationvrcSuctPtTempCLEARcurrentVRC suction temperature clear trap
1.3.6.1.4.1.21239.5.2.32767.0.23012NotificationvrcSuctPtPressureCLEARcurrentVRC suction pressure clear trap
1.3.6.1.4.1.21239.5.2.32767.1NodetrapObj
1.3.6.1.4.1.21239.5.2.32767.1.1ScalartrapSeverityaccessible-for-notifycurrentIndicates the severity of the trap: 0 = None 1 = Warning 2 = Alarm
1.3.6.1.4.1.21239.5.2.32767.1.2ScalartrapThreshTypeaccessible-for-notifycurrentOnly sent for threshold alarms. Identifies the threshold type: 1 = Low 2 = High
1.3.6.1.4.1.21239.42Nodecommon
1.3.6.1.4.1.21239.42.1Nodeidentity
1.3.6.1.4.1.21239.42.1.15Identityr05currentValue given for sysObjectID on R-Series units
1.3.6.1.4.1.21239.42.1.53Identityi03currentValue given for sysObjectID on IMD3 units