MIB Viewer

VMWARE-NSX-MIB

1076 objects
In much the same way that server virtualization programmatically creates, snapshots, deletes, and restores software-based virtual machines (VMs), NSX Data Center network virtualization programmatically creates, deletes, and restores software-based virtual networks. With network virtualization, the functional equivalent of a network hypervisor reproduces the complete set of Layer 2 through Layer 7 networking services (for example, switching, routing, access control, firewalling, QoS) in software. As a result, these services can be programmatically assembled in any arbitrary combination, to produce unique, isolated virtual networks in a matter of seconds. For more information about NSX Data Center, please visit: https://docs.vmware.com/en/VMware-NSX-T-Data-Center/
Imported Objects
SNMPv2-CONFMODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP
SNMPv2-SMIMODULE-IDENTITY NOTIFICATION-TYPE OBJECT-IDENTITY OBJECT-TYPE
SNMPv2-TCDateAndTime TEXTUAL-CONVENTION
VMWARE-ROOT-MIBvmwNSXsys
OIDNameAccessStatusDescription
1.3.6.1.4.1.6876.120.1IdentityvmwNSXsysMIBIn much the same way that server virtualization programmatically creates, snapshots, deletes, and restores software-based virtual machines (VMs), NSX Data Cent…
1.3.6.1.4.1.6876.120.1.0IdentityvmwNsxTDataCenterNotificationscurrentAll event notifications from NSX Data Center fall under this oid.
1.3.6.1.4.1.6876.120.1.0.1IdentityvmwNsxTManagerHealthFeaturePrefixcurrentNotifications applicable to the ManagerHealth feature have this OID prefix.
1.3.6.1.4.1.6876.120.1.0.1.0IdentityvmwNsxTManagerHealthFeaturecurrentSub-identifier added to ensure the next-to-last sub-identifier is zero for ManagerHealth feature notifications.
1.3.6.1.4.1.6876.120.1.0.1.0.1NotificationvmwNsxTManagerHealthManagerCPUUsageHighcurrentThe CPU usage on Manager node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above the high threshold value of vmwN…
1.3.6.1.4.1.6876.120.1.0.1.0.2NotificationvmwNsxTManagerHealthManagerCPUUsageHighClearcurrentThe CPU usage on Manager node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which is below the high threshold value of vmwNsxTDat…
1.3.6.1.4.1.6876.120.1.0.1.0.3NotificationvmwNsxTManagerHealthManagerCPUUsageVeryHighcurrentThe CPU usage on Manager node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above the very high threshold value of…
1.3.6.1.4.1.6876.120.1.0.1.0.4NotificationvmwNsxTManagerHealthManagerCPUUsageVeryHighClearcurrentThe CPU usage on Manager node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which is below the very high threshold value of vmwNs…
1.3.6.1.4.1.6876.120.1.0.1.0.5NotificationvmwNsxTManagerHealthManagerMemoryUsageHighcurrentThe memory usage on Manager node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above the high threshold value of v…
1.3.6.1.4.1.6876.120.1.0.1.0.6NotificationvmwNsxTManagerHealthManagerMemoryUsageHighClearcurrentThe memory usage on Manager node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which is below the high threshold value of vmwNsxT…
1.3.6.1.4.1.6876.120.1.0.1.0.7NotificationvmwNsxTManagerHealthManagerMemoryUsageVeryHighcurrentThe memory usage on Manager node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above the very high threshold value…
1.3.6.1.4.1.6876.120.1.0.1.0.8NotificationvmwNsxTManagerHealthManagerMemoryUsageVeryHighClearcurrentThe memory usage on Manager node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which is below the very high threshold value of vm…
1.3.6.1.4.1.6876.120.1.0.1.0.9NotificationvmwNsxTManagerHealthManagerDiskUsageHighcurrentThe disk usage for the Manager node disk partition vmwNsxTDataCenterDiskPartitionName has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above th…
1.3.6.1.4.1.6876.120.1.0.1.0.10NotificationvmwNsxTManagerHealthManagerDiskUsageHighClearcurrentThe disk usage for the Manager node disk partition vmwNsxTDataCenterDiskPartitionName has reached vmwNsxTDataCenterSystemResourceUsage% which is below the high…
1.3.6.1.4.1.6876.120.1.0.1.0.11NotificationvmwNsxTManagerHealthManagerDiskUsageVeryHighcurrentThe disk usage for the Manager node disk partition vmwNsxTDataCenterDiskPartitionName has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above th…
1.3.6.1.4.1.6876.120.1.0.1.0.12NotificationvmwNsxTManagerHealthManagerDiskUsageVeryHighClearcurrentThe disk usage for the Manager node disk partition vmwNsxTDataCenterDiskPartitionName has reached vmwNsxTDataCenterSystemResourceUsage% which is below the very…
1.3.6.1.4.1.6876.120.1.0.1.0.13NotificationvmwNsxTManagerHealthManagerConfigDiskUsageHighcurrentThe disk usage for the Manager node disk partition /config has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above the high threshold value of v…
1.3.6.1.4.1.6876.120.1.0.1.0.14NotificationvmwNsxTManagerHealthManagerConfigDiskUsageHighClearcurrentThe disk usage for the Manager node disk partition /config has reached vmwNsxTDataCenterSystemResourceUsage% which is below the high threshold value of vmwNsxT…
1.3.6.1.4.1.6876.120.1.0.1.0.15NotificationvmwNsxTManagerHealthManagerConfigDiskUsageVeryHighcurrentThe disk usage for the Manager node disk partition /config has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above the very high threshold value…
1.3.6.1.4.1.6876.120.1.0.1.0.16NotificationvmwNsxTManagerHealthManagerConfigDiskUsageVeryHighClearcurrentThe disk usage for the Manager node disk partition /config has reached vmwNsxTDataCenterSystemResourceUsage% which is below the very high threshold value of vm…
1.3.6.1.4.1.6876.120.1.0.1.0.17NotificationvmwNsxTManagerHealthDuplicateIPAddresscurrentManager node vmwNsxTDataCenterEntityId IP address vmwNsxTDataCenterDuplicateIPAddress is currently being used by another device in the network. Action required…
1.3.6.1.4.1.6876.120.1.0.1.0.18NotificationvmwNsxTManagerHealthDuplicateIPAddressClearcurrentThe device using the IP address assigned to Manager node vmwNsxTDataCenterEntityId appears to no longer be using vmwNsxTDataCenterDuplicateIPAddress. Action re…
1.3.6.1.4.1.6876.120.1.0.1.0.19NotificationvmwNsxTManagerHealthOperationsDbDiskUsageHighcurrentThe disk usage for the Manager node disk partition /nonconfig has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above the high threshold value o…
1.3.6.1.4.1.6876.120.1.0.1.0.20NotificationvmwNsxTManagerHealthOperationsDbDiskUsageHighClearcurrentThe disk usage for the Manager node disk partition /nonconfig has reached vmwNsxTDataCenterSystemResourceUsage% which is below the high threshold value of vmwN…
1.3.6.1.4.1.6876.120.1.0.1.0.21NotificationvmwNsxTManagerHealthOperationsDbDiskUsageVeryHighcurrentThe disk usage for the Manager node disk partition /nonconfig has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above the very high threshold va…
1.3.6.1.4.1.6876.120.1.0.1.0.22NotificationvmwNsxTManagerHealthOperationsDbDiskUsageVeryHighClearcurrentThe disk usage for the Manager node disk partition /nonconfig has reached vmwNsxTDataCenterSystemResourceUsage% which is below the very high threshold value of…
1.3.6.1.4.1.6876.120.1.0.1.0.23NotificationvmwNsxTManagerHealthStorageErrorcurrentThe following disk partition on the Manager node vmwNsxTDataCenterEntityId is in read-only mode: vmwNsxTDataCenterDiskPartitionName Action required: Examine th…
1.3.6.1.4.1.6876.120.1.0.1.0.24NotificationvmwNsxTManagerHealthStorageErrorClearcurrentThe following disk partition on the Manager node vmwNsxTDataCenterEntityId has recovered from read-only mode: vmwNsxTDataCenterDiskPartitionName Action require…
1.3.6.1.4.1.6876.120.1.0.1.0.28NotificationvmwNsxTManagerHealthMissingDNSEntryForManagerFQDNcurrentThe DNS configuration for Manager node vmwNsxTDataCenterManagerNodeName (vmwNsxTDataCenterEntityId) is incorrect. The Manager node is dual-stack and/or CA-sign…
1.3.6.1.4.1.6876.120.1.0.1.0.29NotificationvmwNsxTManagerHealthMissingDNSEntryForManagerFQDNClearcurrentThe DNS configuration for Manager node vmwNsxTDataCenterManagerNodeName (vmwNsxTDataCenterEntityId) is correct. Either the Manager node is not dual-stack and C…
1.3.6.1.4.1.6876.120.1.0.1.0.33NotificationvmwNsxTManagerHealthMissingDNSEntryForVipFQDNcurrentIn case of dual stack or CA-signed API certificate for a NSX Manager, virtual IPv4 address vmwNsxTDataCenterIPv4Address and virtual IPv6 address vmwNsxTDataCen…
1.3.6.1.4.1.6876.120.1.0.1.0.34NotificationvmwNsxTManagerHealthMissingDNSEntryForVipFQDNClearcurrentDual stack VIP addresses for Manager node vmwNsxTDataCenterEntityId resolved to same FQDN. Action required: None, receipt of this notification indicates event …
1.3.6.1.4.1.6876.120.1.0.2IdentityvmwNsxTEdgeHealthFeaturePrefixcurrentNotifications applicable to the EdgeHealth feature have this OID prefix.
1.3.6.1.4.1.6876.120.1.0.2.0IdentityvmwNsxTEdgeHealthFeaturecurrentSub-identifier added to ensure the next-to-last sub-identifier is zero for EdgeHealth feature notifications.
1.3.6.1.4.1.6876.120.1.0.2.0.1NotificationvmwNsxTEdgeHealthEdgeCPUUsageHighcurrentThe CPU usage on Edge node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above the high threshold value of vmwNsxT…
1.3.6.1.4.1.6876.120.1.0.2.0.2NotificationvmwNsxTEdgeHealthEdgeCPUUsageHighClearcurrentThe CPU usage on Edge node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which is below the high threshold value of vmwNsxTDataCe…
1.3.6.1.4.1.6876.120.1.0.2.0.3NotificationvmwNsxTEdgeHealthEdgeCPUUsageVeryHighcurrentThe CPU usage on Edge node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above the very high threshold value of vm…
1.3.6.1.4.1.6876.120.1.0.2.0.4NotificationvmwNsxTEdgeHealthEdgeCPUUsageVeryHighClearcurrentThe CPU usage on Edge node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which is below the very high threshold value of vmwNsxTD…
1.3.6.1.4.1.6876.120.1.0.2.0.5NotificationvmwNsxTEdgeHealthEdgeMemoryUsageHighcurrentThe memory usage on Edge node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above the high threshold value of vmwN…
1.3.6.1.4.1.6876.120.1.0.2.0.6NotificationvmwNsxTEdgeHealthEdgeMemoryUsageHighClearcurrentThe memory usage on Edge node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which is below the high threshold value of vmwNsxTDat…
1.3.6.1.4.1.6876.120.1.0.2.0.7NotificationvmwNsxTEdgeHealthEdgeMemoryUsageVeryHighcurrentThe memory usage on Edge node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above the very high threshold value of…
1.3.6.1.4.1.6876.120.1.0.2.0.8NotificationvmwNsxTEdgeHealthEdgeMemoryUsageVeryHighClearcurrentThe memory usage on Edge node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which is below the very high threshold value of vmwNs…
1.3.6.1.4.1.6876.120.1.0.2.0.9NotificationvmwNsxTEdgeHealthEdgeDiskUsageHighcurrentThe disk usage for the Edge node disk partition vmwNsxTDataCenterDiskPartitionName has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above the h…
1.3.6.1.4.1.6876.120.1.0.2.0.10NotificationvmwNsxTEdgeHealthEdgeDiskUsageHighClearcurrentThe disk usage for the Edge node disk partition vmwNsxTDataCenterDiskPartitionName has reached vmwNsxTDataCenterSystemResourceUsage% which is below the high th…
1.3.6.1.4.1.6876.120.1.0.2.0.11NotificationvmwNsxTEdgeHealthEdgeDiskUsageVeryHighcurrentThe disk usage for the Edge node disk partition vmwNsxTDataCenterDiskPartitionName has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above the v…
1.3.6.1.4.1.6876.120.1.0.2.0.12NotificationvmwNsxTEdgeHealthEdgeDiskUsageVeryHighClearcurrentThe disk usage for the Edge node disk partition vmwNsxTDataCenterDiskPartitionName has reached vmwNsxTDataCenterSystemResourceUsage% which is below the very hi…
1.3.6.1.4.1.6876.120.1.0.2.0.17NotificationvmwNsxTEdgeHealthEdgeDatapathCPUHighcurrentThe datapath CPU usage on Edge node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterDatapathResourceUsage% which is at or above the high threshold for a…
1.3.6.1.4.1.6876.120.1.0.2.0.18NotificationvmwNsxTEdgeHealthEdgeDatapathCPUHighClearcurrentThe CPU usage on Edge node vmwNsxTDataCenterEntityId has reached below the high threshold. Action required: None, receipt of this notification indicates event …
1.3.6.1.4.1.6876.120.1.0.2.0.19NotificationvmwNsxTEdgeHealthEdgeDatapathCPUVeryHighcurrentThe datapath CPU usage on Edge node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterDatapathResourceUsage% which is at or above the very high threshold …
1.3.6.1.4.1.6876.120.1.0.2.0.20NotificationvmwNsxTEdgeHealthEdgeDatapathCPUVeryHighClearcurrentThe CPU usage on Edge node vmwNsxTDataCenterEntityId has reached below the very high threshold. Action required: None, receipt of this notification indicates e…
1.3.6.1.4.1.6876.120.1.0.2.0.21NotificationvmwNsxTEdgeHealthEdgeDatapathConfigurationFailurecurrentFailed to enable the datapath on the Edge node after three attempts. Action required: Ensure the Edge node's connectivity to the Manager node is healthy. From …
1.3.6.1.4.1.6876.120.1.0.2.0.22NotificationvmwNsxTEdgeHealthEdgeDatapathConfigurationFailureClearcurrentDatapath on the Edge node has been successfully enabled. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.2.0.23NotificationvmwNsxTEdgeHealthEdgeDatapathCryptodrvDowncurrentEdge node crypto driver vmwNsxTDataCenterEdgeCryptoDrvName is down. Action required: Upgrade the Edge node as needed.
1.3.6.1.4.1.6876.120.1.0.2.0.24NotificationvmwNsxTEdgeHealthEdgeDatapathCryptodrvDownClearcurrentEdge node crypto driver vmwNsxTDataCenterEdgeCryptoDrvName is up. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.2.0.25NotificationvmwNsxTEdgeHealthEdgeDatapathMempoolHighcurrentThe datapath mempool usage for vmwNsxTDataCenterMempoolName on Edge node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which is a…
1.3.6.1.4.1.6876.120.1.0.2.0.26NotificationvmwNsxTEdgeHealthEdgeDatapathMempoolHighClearcurrentThe datapath mempool usage for vmwNsxTDataCenterMempoolName on Edge node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which is b…
1.3.6.1.4.1.6876.120.1.0.2.0.27NotificationvmwNsxTEdgeHealthEdgeGlobalARPTableUsageHighcurrentGlobal ARP table usage on Edge node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterDatapathResourceUsage% which is above the high threshold for over tw…
1.3.6.1.4.1.6876.120.1.0.2.0.28NotificationvmwNsxTEdgeHealthEdgeGlobalARPTableUsageHighClearcurrentGlobal ARP table usage on Edge node vmwNsxTDataCenterEntityId has reached below the high threshold. Action required: None, receipt of this notification indicat…
1.3.6.1.4.1.6876.120.1.0.2.0.29NotificationvmwNsxTEdgeHealthEdgeNICLinkStatusDowncurrentEdge node NIC vmwNsxTDataCenterEdgeNICName link is down. Action required: On the Edge node confirm if the NIC link is physically down by invoking the NSX CLI c…
1.3.6.1.4.1.6876.120.1.0.2.0.30NotificationvmwNsxTEdgeHealthEdgeNICLinkStatusDownClearcurrentEdge node NIC vmwNsxTDataCenterEdgeNICName link is up. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.2.0.31NotificationvmwNsxTEdgeHealthEdgeNICOutOfReceiveBuffercurrentEdge NIC vmwNsxTDataCenterEdgeNICName receive ring buffer has overflowed by vmwNsxTDataCenterRxRingBufferOverflowPercentage% on Edge node vmwNsxTDataCenterEnti…
1.3.6.1.4.1.6876.120.1.0.2.0.32NotificationvmwNsxTEdgeHealthEdgeNICOutOfReceiveBufferClearcurrentEdge NIC vmwNsxTDataCenterEdgeNICName receive ring buffer usage on Edge node vmwNsxTDataCenterEntityId is no longer overflowing. Action required: None, receipt…
1.3.6.1.4.1.6876.120.1.0.2.0.33NotificationvmwNsxTEdgeHealthEdgeNICOutOfTransmitBuffercurrentEdge NIC vmwNsxTDataCenterEdgeNICName transmit ring buffer has overflowed by vmwNsxTDataCenterTxRingBufferOverflowPercentage% on Edge node vmwNsxTDataCenterEnt…
1.3.6.1.4.1.6876.120.1.0.2.0.34NotificationvmwNsxTEdgeHealthEdgeNICOutOfTransmitBufferClearcurrentEdge NIC vmwNsxTDataCenterEdgeNICName transmit ring buffer usage on Edge node vmwNsxTDataCenterEntityId is no longer overflowing. Action required: None, receip…
1.3.6.1.4.1.6876.120.1.0.2.0.37NotificationvmwNsxTEdgeHealthStorageErrorcurrentThe following disk partitions on the Edge node are in read-only mode: vmwNsxTDataCenterDiskPartitionName Action required: Examine the read-only partition to se…
1.3.6.1.4.1.6876.120.1.0.2.0.38NotificationvmwNsxTEdgeHealthStorageErrorClearcurrentThe following disk partitions on the Edge node have recovered from read-only mode: vmwNsxTDataCenterDiskPartitionName Action required: None, receipt of this no…
1.3.6.1.4.1.6876.120.1.0.2.0.45NotificationvmwNsxTEdgeHealthDatapathThreadDeadlockedcurrentEdge node datapath thread vmwNsxTDataCenterEdgeThreadName is deadlocked. Action required: Restart the dataplane service by invoking the NSX CLI command `restar…
1.3.6.1.4.1.6876.120.1.0.2.0.46NotificationvmwNsxTEdgeHealthDatapathThreadDeadlockedClearcurrentEdge node datapath thread vmwNsxTDataCenterEdgeThreadName is free from deadlock. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.2.0.49NotificationvmwNsxTEdgeHealthEdgeDatapathNICThroughputHighcurrentThe datapath NIC throughput for vmwNsxTDataCenterEdgeNICName on Edge node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterNICThroughput% which is at or …
1.3.6.1.4.1.6876.120.1.0.2.0.50NotificationvmwNsxTEdgeHealthEdgeDatapathNICThroughputHighClearcurrentThe datapath NIC throughput for vmwNsxTDataCenterEdgeNICName on Edge node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterNICThroughput% which is below …
1.3.6.1.4.1.6876.120.1.0.2.0.51NotificationvmwNsxTEdgeHealthEdgeDatapathNICThroughputVeryHighcurrentThe datapath NIC throughput for vmwNsxTDataCenterEdgeNICName on Edge node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterNICThroughput% which is at or …
1.3.6.1.4.1.6876.120.1.0.2.0.52NotificationvmwNsxTEdgeHealthEdgeDatapathNICThroughputVeryHighClearcurrentThe datapath NIC throughput for vmwNsxTDataCenterEdgeNICName on Edge node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterNICThroughput% which is below …
1.3.6.1.4.1.6876.120.1.0.2.0.53NotificationvmwNsxTEdgeHealthFailureDomainDowncurrentAll members of failure domain vmwNsxTDataCenterTransportNodeId are down. Action required: 1. On the Edge node identified by vmwNsxTDataCenterTransportNodeId, c…
1.3.6.1.4.1.6876.120.1.0.2.0.54NotificationvmwNsxTEdgeHealthFailureDomainDownClearcurrentAll members of failure domain vmwNsxTDataCenterTransportNodeId are reachable. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.2.0.55NotificationvmwNsxTEdgeHealthMegaFlowCacheHitRateLowcurrentMega Flow Cache hit rate on Edge node vmwNsxTDataCenterEntityId has decreased below the specified threshold of vmwNsxTDataCenterFlowCacheThreshold% for core vm…
1.3.6.1.4.1.6876.120.1.0.2.0.56NotificationvmwNsxTEdgeHealthMegaFlowCacheHitRateLowClearcurrentFlow Cache hit rate is in the normal range. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.2.0.57NotificationvmwNsxTEdgeHealthMicroFlowCacheHitRateLowcurrentMicro Flow Cache hit rate on Edge node vmwNsxTDataCenterEntityId has decreased below the specified threshold of vmwNsxTDataCenterFlowCacheThreshold% for core v…
1.3.6.1.4.1.6876.120.1.0.2.0.58NotificationvmwNsxTEdgeHealthMicroFlowCacheHitRateLowClearcurrentFlow Cache hit rate is in the normal range. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.3IdentityvmwNsxTCertificatesFeaturePrefixcurrentNotifications applicable to the Certificates feature have this OID prefix.
1.3.6.1.4.1.6876.120.1.0.3.0IdentityvmwNsxTCertificatesFeaturecurrentSub-identifier added to ensure the next-to-last sub-identifier is zero for Certificates feature notifications.
1.3.6.1.4.1.6876.120.1.0.3.0.1NotificationvmwNsxTCertificatesCertificateExpirationApproachingcurrentCertificate vmwNsxTDataCenterEntityId is approaching expiration. Action required: Ensure services that are currently using the certificate are updated to use a…
1.3.6.1.4.1.6876.120.1.0.3.0.2NotificationvmwNsxTCertificatesCertificateExpirationApproachingClearcurrentThe expiring certificate vmwNsxTDataCenterEntityId has been removed or is no longer approaching expiration. Action required: None, receipt of this notification…
1.3.6.1.4.1.6876.120.1.0.3.0.3NotificationvmwNsxTCertificatesCertificateExpiredcurrentCertificate vmwNsxTDataCenterEntityId has expired. Action required: Ensure services that are currently using the certificate are updated to use a new, non-expi…
1.3.6.1.4.1.6876.120.1.0.3.0.4NotificationvmwNsxTCertificatesCertificateExpiredClearcurrentThe expired certificate vmwNsxTDataCenterEntityId has been removed or is no longer expired. Action required: None, receipt of this notification indicates event…
1.3.6.1.4.1.6876.120.1.0.3.0.5NotificationvmwNsxTCertificatesCertificateIsAboutToExpirecurrentCertificate vmwNsxTDataCenterEntityId is about to expire. Action required: Ensure services that are currently using the certificate are updated to use a new, n…
1.3.6.1.4.1.6876.120.1.0.3.0.6NotificationvmwNsxTCertificatesCertificateIsAboutToExpireClearcurrentThe expiring certificate vmwNsxTDataCenterEntityId has been removed or is no longer about to expire. Action required: None, receipt of this notification indica…
1.3.6.1.4.1.6876.120.1.0.3.0.7NotificationvmwNsxTCertificatesCABundleUpdateRecommendedcurrentThe trusted CA bundle vmwNsxTDataCenterEntityId was updated more than vmwNsxTDataCenterCABundleAgeThreshold days ago. Update for the trusted CA bundle is recom…
1.3.6.1.4.1.6876.120.1.0.3.0.8NotificationvmwNsxTCertificatesCABundleUpdateRecommendedClearcurrentThe trusted CA bundle vmwNsxTDataCenterEntityId has been removed, updated, or is no longer in use. Action required: None, receipt of this notification indicate…
1.3.6.1.4.1.6876.120.1.0.3.0.9NotificationvmwNsxTCertificatesCABundleUpdateSuggestedcurrentThe trusted CA bundle vmwNsxTDataCenterEntityId was updated more than vmwNsxTDataCenterCABundleAgeThreshold days ago. Update for the trusted CA bundle is sugge…
1.3.6.1.4.1.6876.120.1.0.3.0.10NotificationvmwNsxTCertificatesCABundleUpdateSuggestedClearcurrentThe trusted CA bundle vmwNsxTDataCenterEntityId has been removed, updated, or is no longer in use. Action required: None, receipt of this notification indicate…
1.3.6.1.4.1.6876.120.1.0.3.0.17NotificationvmwNsxTCertificatesTransportNodeCertificateExpirApproachingcurrentCertificate for Transport node vmwNsxTDataCenterEntityId is approaching expiration. Action required: Replace the Transport node vmwNsxTDataCenterEntityId certi…
1.3.6.1.4.1.6876.120.1.0.3.0.18NotificationvmwNsxTCertificatesTransportNodeCertificateExpirApproachingClearcurrentThe expiring certificate for Transport node vmwNsxTDataCenterEntityId has been removed or is no longer approaching expiration. Action required: None, receipt o…
1.3.6.1.4.1.6876.120.1.0.3.0.19NotificationvmwNsxTCertificatesTransportNodeCertificateExpiredcurrentCertificate has expired for Transport node vmwNsxTDataCenterEntityId. Action required: Replace the Transport node vmwNsxTDataCenterEntityId certificate with a …
1.3.6.1.4.1.6876.120.1.0.3.0.20NotificationvmwNsxTCertificatesTransportNodeCertificateExpiredClearcurrentThe expired certificate for Transport node vmwNsxTDataCenterEntityId has been replaced or is no longer expired. Action required: None, receipt of this notifica…
1.3.6.1.4.1.6876.120.1.0.3.0.21NotificationvmwNsxTCertificatesTransportNodeCertificateIsAboutToExpirecurrentCertificate for Transport node vmwNsxTDataCenterEntityId is about to expire. Action required: Replace the Transport node vmwNsxTDataCenterEntityId certificate …
1.3.6.1.4.1.6876.120.1.0.3.0.22NotificationvmwNsxTCertificatesTransportNodeCertificateIsAboutToExpireClearcurrentThe expiring certificate for Transport node vmwNsxTDataCenterEntityId has been removed or is no longer about to expire. Action required: None, receipt of this …
1.3.6.1.4.1.6876.120.1.0.4IdentityvmwNsxTPasswordManagementFeaturePrefixcurrentNotifications applicable to the PasswordManagement feature have this OID prefix.
1.3.6.1.4.1.6876.120.1.0.4.0IdentityvmwNsxTPasswordManagementFeaturecurrentSub-identifier added to ensure the next-to-last sub-identifier is zero for PasswordManagement feature notifications.
1.3.6.1.4.1.6876.120.1.0.4.0.1NotificationvmwNsxTPasswordManagementPasswordExpirationApproachingcurrentThe password for user vmwNsxTDataCenterUsername is approaching expiration in vmwNsxTDataCenterPasswordExpirationDays days. Action required: The password for th…
1.3.6.1.4.1.6876.120.1.0.4.0.2NotificationvmwNsxTPasswordManagementPasswordExpirationApproachingClearcurrentThe password for the user vmwNsxTDataCenterUsername has been changed successfully or is no longer expired or the user is no longer active. Action required: Non…
1.3.6.1.4.1.6876.120.1.0.4.0.3NotificationvmwNsxTPasswordManagementPasswordExpiredcurrentThe password for user vmwNsxTDataCenterUsername has expired. Action required: The password for user vmwNsxTDataCenterUsername must be changed now to access the…
1.3.6.1.4.1.6876.120.1.0.4.0.4NotificationvmwNsxTPasswordManagementPasswordExpiredClearcurrentThe password for user vmwNsxTDataCenterUsername has been changed successfully or is no longer expired or the user is no longer active. Action required: None, r…
1.3.6.1.4.1.6876.120.1.0.4.0.5NotificationvmwNsxTPasswordManagementPasswordIsAboutToExpirecurrentThe password for user vmwNsxTDataCenterUsername is about to expire in vmwNsxTDataCenterPasswordExpirationDays days. Action required: Ensure the password for th…
1.3.6.1.4.1.6876.120.1.0.4.0.6NotificationvmwNsxTPasswordManagementPasswordIsAboutToExpireClearcurrentThe password for the user vmwNsxTDataCenterUsername has been changed successfully or is no longer expired or the user is no longer active. Action required: Non…
1.3.6.1.4.1.6876.120.1.0.5IdentityvmwNsxTLicensesFeaturePrefixcurrentNotifications applicable to the Licenses feature have this OID prefix.
1.3.6.1.4.1.6876.120.1.0.5.0IdentityvmwNsxTLicensesFeaturecurrentSub-identifier added to ensure the next-to-last sub-identifier is zero for Licenses feature notifications.
1.3.6.1.4.1.6876.120.1.0.5.0.1NotificationvmwNsxTLicensesLicenseExpiredcurrentThe vmwNsxTDataCenterLicenseEditionType license key ending with vmwNsxTDataCenterDisplayedLicenseKey, has expired. Action required: Add a new, non-expired lice…
1.3.6.1.4.1.6876.120.1.0.5.0.2NotificationvmwNsxTLicensesLicenseExpiredClearcurrentThe expired vmwNsxTDataCenterLicenseEditionType license key ending with vmwNsxTDataCenterDisplayedLicenseKey, has been removed, updated or is no longer about t…
1.3.6.1.4.1.6876.120.1.0.5.0.3NotificationvmwNsxTLicensesLicenseIsAboutToExpirecurrentThe vmwNsxTDataCenterLicenseEditionType license key ending with vmwNsxTDataCenterDisplayedLicenseKey, is about to expire. Action required: The license is about…
1.3.6.1.4.1.6876.120.1.0.5.0.4NotificationvmwNsxTLicensesLicenseIsAboutToExpireClearcurrentThe expiring vmwNsxTDataCenterLicenseEditionType license key ending with vmwNsxTDataCenterDisplayedLicenseKey, has been removed, updated or is no longer about …
1.3.6.1.4.1.6876.120.1.0.6IdentityvmwNsxTIntelligenceHealthFeaturePrefixcurrentNotifications applicable to the IntelligenceHealth feature have this OID prefix.
1.3.6.1.4.1.6876.120.1.0.6.0IdentityvmwNsxTIntelligenceHealthFeaturecurrentSub-identifier added to ensure the next-to-last sub-identifier is zero for IntelligenceHealth feature notifications.
1.3.6.1.4.1.6876.120.1.0.6.0.41NotificationvmwNsxTIntelligenceHealthCPUUsageHighcurrentThe CPU usage on Intelligence node vmwNsxTDataCenterIntelligenceNodeId is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action requ…
1.3.6.1.4.1.6876.120.1.0.6.0.42NotificationvmwNsxTIntelligenceHealthCPUUsageHighClearcurrentThe CPU usage on Intelligence node vmwNsxTDataCenterIntelligenceNodeId is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action requ…
1.3.6.1.4.1.6876.120.1.0.6.0.43NotificationvmwNsxTIntelligenceHealthCPUUsageVeryHighcurrentThe CPU usage on Intelligence node vmwNsxTDataCenterIntelligenceNodeId is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action…
1.3.6.1.4.1.6876.120.1.0.6.0.44NotificationvmwNsxTIntelligenceHealthCPUUsageVeryHighClearcurrentThe CPU usage on Intelligence node vmwNsxTDataCenterIntelligenceNodeId is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action…
1.3.6.1.4.1.6876.120.1.0.6.0.45NotificationvmwNsxTIntelligenceHealthDataDiskPartitionUsageHighcurrentThe disk usage of disk partition /data on Intelligence node vmwNsxTDataCenterIntelligenceNodeId is above the high threshold value of vmwNsxTDataCenterSystemUsa…
1.3.6.1.4.1.6876.120.1.0.6.0.46NotificationvmwNsxTIntelligenceHealthDataDiskPartitionUsageHighClearcurrentThe disk usage of disk partition /data on Intelligence node vmwNsxTDataCenterIntelligenceNodeId is below the high threshold value of vmwNsxTDataCenterSystemUsa…
1.3.6.1.4.1.6876.120.1.0.6.0.47NotificationvmwNsxTIntelligenceHealthDataDiskPartitionUsageVeryHighcurrentThe disk usage of disk partition /data on Intelligence node vmwNsxTDataCenterIntelligenceNodeId is above the very high threshold value of vmwNsxTDataCenterSyst…
1.3.6.1.4.1.6876.120.1.0.6.0.48NotificationvmwNsxTIntelligenceHealthDataDiskPartitionUsageVeryHighClearcurrentThe disk usage of disk partition /data on Intelligence node vmwNsxTDataCenterIntelligenceNodeId is below the very high threshold value of vmwNsxTDataCenterSyst…
1.3.6.1.4.1.6876.120.1.0.6.0.49NotificationvmwNsxTIntelligenceHealthDiskUsageHighcurrentThe disk usage of disk partition vmwNsxTDataCenterDiskPartitionName on Intelligence node vmwNsxTDataCenterIntelligenceNodeId is above the high threshold value …
1.3.6.1.4.1.6876.120.1.0.6.0.50NotificationvmwNsxTIntelligenceHealthDiskUsageHighClearcurrentThe disk usage of disk partition vmwNsxTDataCenterDiskPartitionName on Intelligence node vmwNsxTDataCenterIntelligenceNodeId is below the high threshold value …
1.3.6.1.4.1.6876.120.1.0.6.0.51NotificationvmwNsxTIntelligenceHealthDiskUsageVeryHighcurrentThe disk usage of disk partition vmwNsxTDataCenterDiskPartitionName on Intelligence node vmwNsxTDataCenterIntelligenceNodeId is above the very high threshold v…
1.3.6.1.4.1.6876.120.1.0.6.0.52NotificationvmwNsxTIntelligenceHealthDiskUsageVeryHighClearcurrentThe disk usage of disk partition vmwNsxTDataCenterDiskPartitionName on Intelligence node vmwNsxTDataCenterIntelligenceNodeId is below the very high threshold v…
1.3.6.1.4.1.6876.120.1.0.6.0.53NotificationvmwNsxTIntelligenceHealthMemoryUsageHighcurrentThe memory usage on Intelligence node vmwNsxTDataCenterIntelligenceNodeId is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action r…
1.3.6.1.4.1.6876.120.1.0.6.0.54NotificationvmwNsxTIntelligenceHealthMemoryUsageHighClearcurrentThe memory usage on Intelligence node vmwNsxTDataCenterIntelligenceNodeId is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action r…
1.3.6.1.4.1.6876.120.1.0.6.0.55NotificationvmwNsxTIntelligenceHealthMemoryUsageVeryHighcurrentThe memory usage on Intelligence node vmwNsxTDataCenterIntelligenceNodeId is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Act…
1.3.6.1.4.1.6876.120.1.0.6.0.56NotificationvmwNsxTIntelligenceHealthMemoryUsageVeryHighClearcurrentThe memory usage on Intelligence node vmwNsxTDataCenterIntelligenceNodeId is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Act…
1.3.6.1.4.1.6876.120.1.0.6.0.57NotificationvmwNsxTIntelligenceHealthNodeStatusDegradedcurrentIntelligence node vmwNsxTDataCenterIntelligenceNodeId is degraded. Action required: Invoke the NSX API GET /napp/api/v1/platform/monitor/category/health to che…
1.3.6.1.4.1.6876.120.1.0.6.0.58NotificationvmwNsxTIntelligenceHealthNodeStatusDegradedClearcurrentIntelligence node vmwNsxTDataCenterIntelligenceNodeId is running properly. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.6.0.63NotificationvmwNsxTIntelligenceHealthStorageLatencyHighcurrentThe storage latency of disk partition vmwNsxTDataCenterDiskPartitionName on Intelligence node vmwNsxTDataCenterIntelligenceNodeId is above the high threshold v…
1.3.6.1.4.1.6876.120.1.0.6.0.64NotificationvmwNsxTIntelligenceHealthStorageLatencyHighClearcurrentThe storage latency of disk partition vmwNsxTDataCenterDiskPartitionName on Intelligence node vmwNsxTDataCenterIntelligenceNodeId is below the high threshold v…
1.3.6.1.4.1.6876.120.1.0.7IdentityvmwNsxTInfrastructureCommunicationFeaturePrefixcurrentNotifications applicable to the InfrastructureCommunication feature have this OID prefix.
1.3.6.1.4.1.6876.120.1.0.7.0IdentityvmwNsxTInfrastructureCommunicationFeaturecurrentSub-identifier added to ensure the next-to-last sub-identifier is zero for InfrastructureCommunication feature notifications.
1.3.6.1.4.1.6876.120.1.0.7.0.17NotificationvmwNsxTInfrastructureCommunicationEdgeTunnelsDowncurrentThe overall tunnel status of Edge node vmwNsxTDataCenterEntityId is down. Action required: Invoke the NSX CLI command `get tunnel-ports` to get all tunnel port…
1.3.6.1.4.1.6876.120.1.0.7.0.18NotificationvmwNsxTInfrastructureCommunicationEdgeTunnelsDownClearcurrentThe tunnels of Edge node vmwNsxTDataCenterEntityId have been restored. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.9IdentityvmwNsxTIntelligenceCommunicationFeaturePrefixcurrentNotifications applicable to the IntelligenceCommunication feature have this OID prefix.
1.3.6.1.4.1.6876.120.1.0.9.0IdentityvmwNsxTIntelligenceCommunicationFeaturecurrentSub-identifier added to ensure the next-to-last sub-identifier is zero for IntelligenceCommunication feature notifications.
1.3.6.1.4.1.6876.120.1.0.9.0.7NotificationvmwNsxTIntelligenceCommunicationTNFlowExporterDisconnectedcurrentThe flow exporter on Transport node vmwNsxTDataCenterEntityId is disconnected from the Intelligence node's messaging broker. Data collection is affected. Actio…
1.3.6.1.4.1.6876.120.1.0.9.0.8NotificationvmwNsxTIntelligenceCommunicationTNFlowExporterDisconnectedClearcurrentThe flow exporter on Transport node vmwNsxTDataCenterEntityId has reconnected to the Intelligence node's messaging broker. Action required: None, receipt of th…
1.3.6.1.4.1.6876.120.1.0.10IdentityvmwNsxTCniHealthFeaturePrefixcurrentNotifications applicable to the CniHealth feature have this OID prefix.
1.3.6.1.4.1.6876.120.1.0.10.0IdentityvmwNsxTCniHealthFeaturecurrentSub-identifier added to ensure the next-to-last sub-identifier is zero for CniHealth feature notifications.
1.3.6.1.4.1.6876.120.1.0.10.0.3NotificationvmwNsxTCniHealthHyperbusManagerConnectionDowncurrentHyperbus cannot communicate with the Manager node. Action required: The hyperbus vmkernel interface (vmk50) may be missing. Refer to Knowledge Base article htt…
1.3.6.1.4.1.6876.120.1.0.10.0.4NotificationvmwNsxTCniHealthHyperbusManagerConnectionDownClearcurrentHyperbus can communicate with the Manager node. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.10.0.5NotificationvmwNsxTCniHealthHyperbusManagerConnectionDownOnDPUcurrentHyperbus on DPU vmwNsxTDataCenterDPUId cannot communicate with the Manager node. Action required: The hyperbus vmkernel interface (vmk50) on DPU vmwNsxTDataCen…
1.3.6.1.4.1.6876.120.1.0.10.0.6NotificationvmwNsxTCniHealthHyperbusManagerConnectionDownOnDPUClearcurrentHyperbus on DPU vmwNsxTDataCenterDPUId can communicate with the Manager node. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.11IdentityvmwNsxTNCPHealthFeaturePrefixcurrentNotifications applicable to the NCPHealth feature have this OID prefix.
1.3.6.1.4.1.6876.120.1.0.11.0IdentityvmwNsxTNCPHealthFeaturecurrentSub-identifier added to ensure the next-to-last sub-identifier is zero for NCPHealth feature notifications.
1.3.6.1.4.1.6876.120.1.0.11.0.3NotificationvmwNsxTNCPHealthNCPPluginDowncurrentManager Node has detected the NCP is down or unhealthy. Action required: To find the clusters which are having issues, use the NSX UI and navigate to the Alarm…
1.3.6.1.4.1.6876.120.1.0.11.0.4NotificationvmwNsxTNCPHealthNCPPluginDownClearcurrentManager Node has detected the NCP is up or healthy again. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.12IdentityvmwNsxTNodeAgentsHealthFeaturePrefixcurrentNotifications applicable to the NodeAgentsHealth feature have this OID prefix.
1.3.6.1.4.1.6876.120.1.0.12.0IdentityvmwNsxTNodeAgentsHealthFeaturecurrentSub-identifier added to ensure the next-to-last sub-identifier is zero for NodeAgentsHealth feature notifications.
1.3.6.1.4.1.6876.120.1.0.12.0.3NotificationvmwNsxTNodeAgentsHealthNodeAgentsDowncurrentThe agents running inside the Node VM appear to be down. Action required: For ESX: 1. If Vmk50 is missing, refer to this Knowledge Base article https://kb.vmwa…
1.3.6.1.4.1.6876.120.1.0.12.0.4NotificationvmwNsxTNodeAgentsHealthNodeAgentsDownClearcurrentThe agents inside the Node VM are running. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.12.0.5NotificationvmwNsxTNodeAgentsHealthNodeAgentsDownOnDPUcurrentThe agents running inside the Node VM appear to be down on DPU vmwNsxTDataCenterDPUId. Action required: 1. If Vmk50 on DPU vmwNsxTDataCenterDPUId is missing, r…
1.3.6.1.4.1.6876.120.1.0.12.0.6NotificationvmwNsxTNodeAgentsHealthNodeAgentsDownOnDPUClearcurrentThe agents inside the Node VM are running on DPU vmwNsxTDataCenterDPUId. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.13IdentityvmwNsxTEndpointProtectionFeaturePrefixcurrentNotifications applicable to the EndpointProtection feature have this OID prefix.
1.3.6.1.4.1.6876.120.1.0.13.0IdentityvmwNsxTEndpointProtectionFeaturecurrentSub-identifier added to ensure the next-to-last sub-identifier is zero for EndpointProtection feature notifications.
1.3.6.1.4.1.6876.120.1.0.13.0.1NotificationvmwNsxTEndpointProtectionEAMStatusDowncurrentESX Agent Manager (EAM) service on compute manager vmwNsxTDataCenterEntityId is down. Action required: Start the ESX Agent Manager (EAM) service. SSH into vCen…
1.3.6.1.4.1.6876.120.1.0.13.0.2NotificationvmwNsxTEndpointProtectionEAMStatusDownClearcurrentESX Agent Manager (EAM) service on compute manager vmwNsxTDataCenterEntityId is either up or compute manager vmwNsxTDataCenterEntityId has been removed. Action…
1.3.6.1.4.1.6876.120.1.0.13.0.3NotificationvmwNsxTEndpointProtectionPartnerChannelDowncurrentThe connection between host module and Partner SVM vmwNsxTDataCenterEntityId is down. Action required: Refer to https://kb.vmware.com/s/article/85844 and make …
1.3.6.1.4.1.6876.120.1.0.13.0.4NotificationvmwNsxTEndpointProtectionPartnerChannelDownClearcurrentThe connection between host module and Partner SVM vmwNsxTDataCenterEntityId is up. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.14IdentityvmwNsxTServiceInsertionFeaturePrefixcurrentNotifications applicable to the ServiceInsertion feature have this OID prefix.
1.3.6.1.4.1.6876.120.1.0.14.0IdentityvmwNsxTServiceInsertionFeaturecurrentSub-identifier added to ensure the next-to-last sub-identifier is zero for ServiceInsertion feature notifications.
1.3.6.1.4.1.6876.120.1.0.14.0.7NotificationvmwNsxTServiceInsertionNewHostAddedcurrentNew host added in cluster vmwNsxTDataCentervCenterClusterId and SVM will be deployed. Action required: Check for the VM deployment status and wait till it powe…
1.3.6.1.4.1.6876.120.1.0.14.0.8NotificationvmwNsxTServiceInsertionNewHostAddedClearcurrentNew host added successfully. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.14.0.9NotificationvmwNsxTServiceInsertionServiceDeploymentFailedcurrentThe service deployment vmwNsxTDataCenterEntityId for service vmwNsxTDataCenterServiceName on cluster vmwNsxTDataCentervCenterClusterId has failed. Reason : vmw…
1.3.6.1.4.1.6876.120.1.0.14.0.10NotificationvmwNsxTServiceInsertionServiceDeploymentFailedClearcurrentThe failed service deployment vmwNsxTDataCenterEntityId has been removed. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.14.0.11NotificationvmwNsxTServiceInsertionServiceDeploymentSucceededcurrentThe service deployment vmwNsxTDataCenterEntityId for service vmwNsxTDataCenterServiceName on cluster vmwNsxTDataCentervCenterClusterId has succeeded. Action re…
1.3.6.1.4.1.6876.120.1.0.14.0.12NotificationvmwNsxTServiceInsertionServiceDeploymentSucceededClearcurrentThe service deployment vmwNsxTDataCenterEntityId on cluster vmwNsxTDataCentervCenterClusterId has succeeded, no action needed. Action required: None, receipt o…
1.3.6.1.4.1.6876.120.1.0.14.0.15NotificationvmwNsxTServiceInsertionServiceUndeploymentFailedcurrentThe deletion of service deployment vmwNsxTDataCenterEntityId for service vmwNsxTDataCenterServiceName on cluster vmwNsxTDataCentervCenterClusterId has failed. …
1.3.6.1.4.1.6876.120.1.0.14.0.16NotificationvmwNsxTServiceInsertionServiceUndeploymentFailedClearcurrentThe failed service deployment name vmwNsxTDataCenterEntityId has been removed. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.14.0.17NotificationvmwNsxTServiceInsertionServiceUndeploymentSucceededcurrentThe deletion of service deployment vmwNsxTDataCenterEntityId for service vmwNsxTDataCenterServiceName on cluster vmwNsxTDataCentervCenterClusterId has succeede…
1.3.6.1.4.1.6876.120.1.0.14.0.18NotificationvmwNsxTServiceInsertionServiceUndeploymentSucceededClearcurrentThe deletion of service deployment vmwNsxTDataCenterEntityId on cluster vmwNsxTDataCentervCenterClusterId has succeeded, no action needed. Action required: Non…
1.3.6.1.4.1.6876.120.1.0.14.0.21NotificationvmwNsxTServiceInsertionServiceChainPathDowncurrentService chain path is down on vmwNsxTDataCenterEntityId and traffic flow is impacted. Action required: Perform any corrective action from the KB and check if t…
1.3.6.1.4.1.6876.120.1.0.14.0.22NotificationvmwNsxTServiceInsertionServiceChainPathDownClearcurrentService chain path is up and configured as expected. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.14.0.23NotificationvmwNsxTServiceInsertionSVMHealthStatusDowncurrentThe health check for SVM vmwNsxTDataCenterEntityId for service vmwNsxTDataCenterServiceName is not working correctly on vmwNsxTDataCenterHostnameOrIPAddressWit…
1.3.6.1.4.1.6876.120.1.0.14.0.24NotificationvmwNsxTServiceInsertionSVMHealthStatusDownClearcurrentThe SVM vmwNsxTDataCenterEntityId with wrong state has been removed. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.14.0.25NotificationvmwNsxTServiceInsertionSVMHealthStatusUpcurrentThe health check for SVM vmwNsxTDataCenterEntityId for service vmwNsxTDataCenterServiceName is working correctly on vmwNsxTDataCenterHostnameOrIPAddressWithPor…
1.3.6.1.4.1.6876.120.1.0.14.0.26NotificationvmwNsxTServiceInsertionSVMHealthStatusUpClearcurrentThe SVM vmwNsxTDataCenterEntityId is working correctly, no action needed. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.14.0.27NotificationvmwNsxTServiceInsertionSVMLivenessStateDowncurrentSVM liveness state is down on vmwNsxTDataCenterEntityId and traffic flow is impacted. Action required: Perform any corrective action from the KB and check if t…
1.3.6.1.4.1.6876.120.1.0.14.0.28NotificationvmwNsxTServiceInsertionSVMLivenessStateDownClearcurrentSVM liveness state is up and configured as expected. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.14.0.29NotificationvmwNsxTServiceInsertionServiceInsertionInfraStatusDowncurrentSPF not enabled at port level on host vmwNsxTDataCenterTransportNodeId and the status is down. Reason : vmwNsxTDataCenterFailureReason. Action required: Perfor…
1.3.6.1.4.1.6876.120.1.0.14.0.30NotificationvmwNsxTServiceInsertionServiceInsertionInfraStatusDownClearcurrentService insertion infrastructure status is up and has been correctly enabled on host. Action required: None, receipt of this notification indicates event clear…
1.3.6.1.4.1.6876.120.1.0.15IdentityvmwNsxTVPNFeaturePrefixcurrentNotifications applicable to the VPN feature have this OID prefix.
1.3.6.1.4.1.6876.120.1.0.15.0IdentityvmwNsxTVPNFeaturecurrentSub-identifier added to ensure the next-to-last sub-identifier is zero for VPN feature notifications.
1.3.6.1.4.1.6876.120.1.0.15.0.7NotificationvmwNsxTVPNIPsecPolicyBasedSessionDowncurrentThe policy based IPsec VPN session vmwNsxTDataCenterEntityId is down. Reason: vmwNsxTDataCenterSessionDownReason. Action required: Check IPsec VPN session conf…
1.3.6.1.4.1.6876.120.1.0.15.0.8NotificationvmwNsxTVPNIPsecPolicyBasedSessionDownClearcurrentThe policy based IPsec VPN session vmwNsxTDataCenterEntityId is up. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.15.0.9NotificationvmwNsxTVPNIPsecPolicyBasedTunnelDowncurrentOne or more policy based IPsec VPN tunnels in session vmwNsxTDataCenterEntityId are down. Action required: Check IPsec VPN session configuration and resolve er…
1.3.6.1.4.1.6876.120.1.0.15.0.10NotificationvmwNsxTVPNIPsecPolicyBasedTunnelDownClearcurrentAll policy based IPsec VPN tunnels in session vmwNsxTDataCenterEntityId are up. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.15.0.11NotificationvmwNsxTVPNIPsecRouteBasedSessionDowncurrentThe route based IPsec VPN session vmwNsxTDataCenterEntityId is down. Reason: vmwNsxTDataCenterSessionDownReason. Action required: Check IPsec VPN session confi…
1.3.6.1.4.1.6876.120.1.0.15.0.12NotificationvmwNsxTVPNIPsecRouteBasedSessionDownClearcurrentThe route based IPsec VPN session vmwNsxTDataCenterEntityId is up. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.15.0.13NotificationvmwNsxTVPNIPsecRouteBasedTunnelDowncurrentThe route based IPsec VPN tunnel in session vmwNsxTDataCenterEntityId is down. Reason: vmwNsxTDataCenterTunnelDownReason. Action required: Check IPsec VPN sess…
1.3.6.1.4.1.6876.120.1.0.15.0.14NotificationvmwNsxTVPNIPsecRouteBasedTunnelDownClearcurrentThe route based IPsec VPN tunnel in session vmwNsxTDataCenterEntityId is up. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.15.0.15NotificationvmwNsxTVPNL2VpnSessionDowncurrentThe L2VPN session vmwNsxTDataCenterEntityId is down. Action required: Check L2VPN session status for session down reason and resolve errors based on the reason.
1.3.6.1.4.1.6876.120.1.0.15.0.16NotificationvmwNsxTVPNL2VpnSessionDownClearcurrentThe L2VPN session vmwNsxTDataCenterEntityId is up. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.15.0.17NotificationvmwNsxTVPNIPsecServiceDowncurrentThe IPsec service vmwNsxTDataCenterEntityId is down. Reason: vmwNsxTDataCenterServiceDownReason. Action required: 1. Disable and enable the IPsec service from …
1.3.6.1.4.1.6876.120.1.0.15.0.18NotificationvmwNsxTVPNIPsecServiceDownClearcurrentThe IPsec service vmwNsxTDataCenterEntityId is up. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.16IdentityvmwNsxTAlarmManagementFeaturePrefixcurrentNotifications applicable to the AlarmManagement feature have this OID prefix.
1.3.6.1.4.1.6876.120.1.0.16.0IdentityvmwNsxTAlarmManagementFeaturecurrentSub-identifier added to ensure the next-to-last sub-identifier is zero for AlarmManagement feature notifications.
1.3.6.1.4.1.6876.120.1.0.16.0.1NotificationvmwNsxTAlarmManagementAlarmServiceOverloadedcurrentDue to heavy volume of alarms reported, the alarm service is temporarily overloaded. The NSX UI and GET /api/v1/alarms NSX API have stopped reporting new alarm…
1.3.6.1.4.1.6876.120.1.0.16.0.2NotificationvmwNsxTAlarmManagementAlarmServiceOverloadedClearcurrentThe heavy volume of alarms has subsided and new alarms are being reported again. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.16.0.3NotificationvmwNsxTAlarmManagementHeavyVolumeOfAlarmscurrentDue to heavy volume of vmwNsxTDataCenterEventId alarms, the alarm service has temporarily stopped reporting alarms of this type. The NSX UI and GET /api/v1/ala…
1.3.6.1.4.1.6876.120.1.0.16.0.4NotificationvmwNsxTAlarmManagementHeavyVolumeOfAlarmsClearcurrentThe heavy volume of vmwNsxTDataCenterEventId alarms has subsided and new alarms of this type are being reported again. Action required: None, receipt of this n…
1.3.6.1.4.1.6876.120.1.0.17IdentityvmwNsxTLoadBalancerFeaturePrefixcurrentNotifications applicable to the LoadBalancer feature have this OID prefix.
1.3.6.1.4.1.6876.120.1.0.17.0IdentityvmwNsxTLoadBalancerFeaturecurrentSub-identifier added to ensure the next-to-last sub-identifier is zero for LoadBalancer feature notifications.
1.3.6.1.4.1.6876.120.1.0.17.0.1NotificationvmwNsxTLoadBalancerLBCPUVeryHighcurrentThe CPU usage of load balancer vmwNsxTDataCenterEntityId is very high. The threshold is vmwNsxTDataCenterSystemUsageThreshold%. Action required: If the load ba…
1.3.6.1.4.1.6876.120.1.0.17.0.2NotificationvmwNsxTLoadBalancerLBCPUVeryHighClearcurrentThe CPU usage of load balancer vmwNsxTDataCenterEntityId is low enough. The threshold is vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt…
1.3.6.1.4.1.6876.120.1.0.17.0.3NotificationvmwNsxTLoadBalancerLBEdgeCapacityInUseHighcurrentThe usage of load balancer service in Edge node vmwNsxTDataCenterEntityId is high. The threshold is vmwNsxTDataCenterSystemUsageThreshold%. Action required: If…
1.3.6.1.4.1.6876.120.1.0.17.0.4NotificationvmwNsxTLoadBalancerLBEdgeCapacityInUseHighClearcurrentThe usage of load balancer service in Edge node vmwNsxTDataCenterEntityId is low enough. The threshold is vmwNsxTDataCenterSystemUsageThreshold%. Action requir…
1.3.6.1.4.1.6876.120.1.0.17.0.5NotificationvmwNsxTLoadBalancerLBPoolMemberCapacityInUseVeryHighcurrentThe usage of pool members in Edge node vmwNsxTDataCenterEntityId is very high. The threshold is vmwNsxTDataCenterSystemUsageThreshold%. Action required: Deploy…
1.3.6.1.4.1.6876.120.1.0.17.0.6NotificationvmwNsxTLoadBalancerLBPoolMemberCapacityInUseVeryHighClearcurrentThe usage of pool members in Edge node vmwNsxTDataCenterEntityId is low enough. The threshold is vmwNsxTDataCenterSystemUsageThreshold%. Action required: None,…
1.3.6.1.4.1.6876.120.1.0.17.0.7NotificationvmwNsxTLoadBalancerLBStatusDowncurrentThe centralized load balancer service vmwNsxTDataCenterEntityId is down. Action required: On active Edge node, check load balancer status by invoking the NSX C…
1.3.6.1.4.1.6876.120.1.0.17.0.8NotificationvmwNsxTLoadBalancerLBStatusDownClearcurrentThe centralized load balancer service vmwNsxTDataCenterEntityId is up. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.17.0.9NotificationvmwNsxTLoadBalancerPoolStatusDowncurrentThe load balancer pool vmwNsxTDataCenterEntityId status is down. Action required: Consult the load balancer pool to determine which members are down by invokin…
1.3.6.1.4.1.6876.120.1.0.17.0.10NotificationvmwNsxTLoadBalancerPoolStatusDownClearcurrentThe load balancer pool vmwNsxTDataCenterEntityId status is up Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.17.0.11NotificationvmwNsxTLoadBalancerVirtualServerStatusDowncurrentThe load balancer virtual server vmwNsxTDataCenterEntityId is down. Action required: Consult the load balancer pool to determine its status and verify its conf…
1.3.6.1.4.1.6876.120.1.0.17.0.12NotificationvmwNsxTLoadBalancerVirtualServerStatusDownClearcurrentThe load balancer virtual server vmwNsxTDataCenterEntityId is up. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.17.0.15NotificationvmwNsxTLoadBalancerLBStatusDegradedcurrentThe load balancer service vmwNsxTDataCenterEntityId is degraded. Action required: For centralized load balancer: Check the load balancer status on standby Edge…
1.3.6.1.4.1.6876.120.1.0.17.0.16NotificationvmwNsxTLoadBalancerLBStatusDegradedClearcurrentThe load balancer service vmwNsxTDataCenterEntityId is not degraded. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.17.0.17NotificationvmwNsxTLoadBalancerDLBStatusDowncurrentThe distributed load balancer service vmwNsxTDataCenterEntityId is down. Action required: On ESXi host node, invoke the NSX CLI command `get load-balancer <lb-…
1.3.6.1.4.1.6876.120.1.0.17.0.18NotificationvmwNsxTLoadBalancerDLBStatusDownClearcurrentThe distributed load balancer service vmwNsxTDataCenterEntityId is up. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.17.0.19NotificationvmwNsxTLoadBalancerConfigurationNotRealizedDueToLowMemorycurrentThe load balancer configuration vmwNsxTDataCenterEntityId is not realized, due to high memory usage on Edge node vmwNsxTDataCenterTransportNodeId. Action requi…
1.3.6.1.4.1.6876.120.1.0.17.0.20NotificationvmwNsxTLoadBalancerConfigurationNotRealizedDueToLowMemoryClearcurrentThe load balancer configuration vmwNsxTDataCenterEntityId is realized on vmwNsxTDataCenterTransportNodeId. Action required: None, receipt of this notification …
1.3.6.1.4.1.6876.120.1.0.18IdentityvmwNsxTTransportNodeHealthFeaturePrefixcurrentNotifications applicable to the TransportNodeHealth feature have this OID prefix.
1.3.6.1.4.1.6876.120.1.0.18.0IdentityvmwNsxTTransportNodeHealthFeaturecurrentSub-identifier added to ensure the next-to-last sub-identifier is zero for TransportNodeHealth feature notifications.
1.3.6.1.4.1.6876.120.1.0.18.0.3NotificationvmwNsxTTransportNodeHealthNVDSUplinkDowncurrentUplink is going down. Action required: Check the physical NICs' status of uplinks on hosts. 1. In the NSX UI navigate to Fabric | Nodes | Transport Nodes | Hos…
1.3.6.1.4.1.6876.120.1.0.18.0.4NotificationvmwNsxTTransportNodeHealthNVDSUplinkDownClearcurrentUplink is going up. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.18.0.5NotificationvmwNsxTTransportNodeHealthLAGMemberDowncurrentLACP reporting member down. Action required: Check the connection status of LAG members on hosts. 1. In the NSX UI navigate to Fabric | Nodes | Transport Nodes…
1.3.6.1.4.1.6876.120.1.0.18.0.6NotificationvmwNsxTTransportNodeHealthLAGMemberDownClearcurrentLACP reporting member up. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.18.0.7NotificationvmwNsxTTransportNodeHealthTransportNodeUplinkDowncurrentUplink is going down. Action required: Check the physical NICs' status of uplinks on hosts. 1. In the NSX UI navigate to Fabric | Nodes | Transport Nodes | Hos…
1.3.6.1.4.1.6876.120.1.0.18.0.8NotificationvmwNsxTTransportNodeHealthTransportNodeUplinkDownClearcurrentUplink is going up. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.18.0.9NotificationvmwNsxTTransportNodeHealthLAGMemberDownOnDPUcurrentLACP on DPU vmwNsxTDataCenterDPUId reporting member down. Action required: Check the connection status of LAG members on DPU vmwNsxTDataCenterDPUId. Find out t…
1.3.6.1.4.1.6876.120.1.0.18.0.10NotificationvmwNsxTTransportNodeHealthLAGMemberDownOnDPUClearcurrentLACP on DPU vmwNsxTDataCenterDPUId reporting member up. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.18.0.11NotificationvmwNsxTTransportNodeHealthTransportNodeUplinkDownOnDPUcurrentUplink on DPU vmwNsxTDataCenterDPUId is going down. Action required: Check the physical NICs' status of uplinks on DPU vmwNsxTDataCenterDPUId. Find out the map…
1.3.6.1.4.1.6876.120.1.0.18.0.12NotificationvmwNsxTTransportNodeHealthTransportNodeUplinkDownOnDPUClearcurrentUplink on DPU vmwNsxTDataCenterDPUId is going up. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.19IdentityvmwNsxTInfrastructureServiceFeaturePrefixcurrentNotifications applicable to the InfrastructureService feature have this OID prefix.
1.3.6.1.4.1.6876.120.1.0.19.0IdentityvmwNsxTInfrastructureServiceFeaturecurrentSub-identifier added to ensure the next-to-last sub-identifier is zero for InfrastructureService feature notifications.
1.3.6.1.4.1.6876.120.1.0.19.0.1NotificationvmwNsxTInfrastructureServiceEdgeServiceStatusChangedcurrentThe service vmwNsxTDataCenterEdgeServiceName changed from vmwNsxTDataCenterPreviousServiceState to vmwNsxTDataCenterCurrentServiceState. vmwNsxTDataCenterServi…
1.3.6.1.4.1.6876.120.1.0.19.0.2NotificationvmwNsxTInfrastructureServiceEdgeServiceStatusChangedClearcurrentThe service vmwNsxTDataCenterEdgeServiceName changed from vmwNsxTDataCenterPreviousServiceState to vmwNsxTDataCenterCurrentServiceState. Action required: None,…
1.3.6.1.4.1.6876.120.1.0.19.0.3NotificationvmwNsxTInfrastructureServiceEdgeServiceStatusDowncurrentThe service vmwNsxTDataCenterEdgeServiceName is down for at least one minute. vmwNsxTDataCenterServiceDownReason Action required: On the Edge node, verify the …
1.3.6.1.4.1.6876.120.1.0.19.0.4NotificationvmwNsxTInfrastructureServiceEdgeServiceStatusDownClearcurrentThe service vmwNsxTDataCenterEdgeServiceName is up. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.19.0.7NotificationvmwNsxTInfrastructureServiceServiceStatusUnknowncurrentThe service vmwNsxTDataCenterServiceName has been unresponsive for 10 seconds. Action required: Verify vmwNsxTDataCenterServiceName service is still running by…
1.3.6.1.4.1.6876.120.1.0.19.0.8NotificationvmwNsxTInfrastructureServiceServiceStatusUnknownClearcurrentThe service vmwNsxTDataCenterServiceName is responsive again. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.19.0.9NotificationvmwNsxTInfrastructureServiceApplicationCrashedcurrentApplication on NSX node vmwNsxTDataCenterNodeDisplayOrHostName has crashed. The number of core files found is vmwNsxTDataCenterCoreDumpCount. Collect the Suppo…
1.3.6.1.4.1.6876.120.1.0.19.0.10NotificationvmwNsxTInfrastructureServiceApplicationCrashedClearcurrentAll core dump files are withdrawn from system. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.19.0.11NotificationvmwNsxTInfrastructureServiceServiceStatusUnknownOnDPUcurrentThe service vmwNsxTDataCenterServiceName on DPU vmwNsxTDataCenterDPUId has been unresponsive for 10 seconds. Action required: Verify vmwNsxTDataCenterServiceNa…
1.3.6.1.4.1.6876.120.1.0.19.0.12NotificationvmwNsxTInfrastructureServiceServiceStatusUnknownOnDPUClearcurrentThe service vmwNsxTDataCenterServiceName on DPU vmwNsxTDataCenterDPUId is responsive again. Action required: None, receipt of this notification indicates event…
1.3.6.1.4.1.6876.120.1.0.19.0.19NotificationvmwNsxTInfrastructureServiceMetricsDeliveryFailurecurrentFailed to deliver metrics from SHA to target vmwNsxTDataCenterMetricsTargetAlias(vmwNsxTDataCenterMetricsTargetAddress:vmwNsxTDataCenterMetricsTargetPort). Act…
1.3.6.1.4.1.6876.120.1.0.19.0.20NotificationvmwNsxTInfrastructureServiceMetricsDeliveryFailureClearcurrentMetrics delivery to target vmwNsxTDataCenterMetricsTargetAlias(vmwNsxTDataCenterMetricsTargetAddress:vmwNsxTDataCenterMetricsTargetPort) recovered. Action requ…
1.3.6.1.4.1.6876.120.1.0.20IdentityvmwNsxTDHCPFeaturePrefixcurrentNotifications applicable to the DHCP feature have this OID prefix.
1.3.6.1.4.1.6876.120.1.0.20.0IdentityvmwNsxTDHCPFeaturecurrentSub-identifier added to ensure the next-to-last sub-identifier is zero for DHCP feature notifications.
1.3.6.1.4.1.6876.120.1.0.20.0.1NotificationvmwNsxTDHCPPoolLeaseAllocationFailedcurrentThe addresses in IP Pool vmwNsxTDataCenterEntityId of DHCP Server vmwNsxTDataCenterDHCPServerId have been exhausted. The last DHCP request has failed and futur…
1.3.6.1.4.1.6876.120.1.0.20.0.2NotificationvmwNsxTDHCPPoolLeaseAllocationFailedClearcurrentIP Pool vmwNsxTDataCenterEntityId of DHCP Server vmwNsxTDataCenterDHCPServerId is no longer exhausted. A lease is successfully allocated to the last DHCP reque…
1.3.6.1.4.1.6876.120.1.0.20.0.3NotificationvmwNsxTDHCPPoolOverloadedcurrentThe DHCP Server vmwNsxTDataCenterDHCPServerId IP Pool vmwNsxTDataCenterEntityId usage is approaching exhaustion with vmwNsxTDataCenterDHCPPoolUsage% IPs alloca…
1.3.6.1.4.1.6876.120.1.0.20.0.4NotificationvmwNsxTDHCPPoolOverloadedClearcurrentThe DHCP Server vmwNsxTDataCenterDHCPServerId IP Pool vmwNsxTDataCenterEntityId has fallen below the high usage threshold. Action required: None, receipt of th…
1.3.6.1.4.1.6876.120.1.0.21IdentityvmwNsxTHighAvailabilityFeaturePrefixcurrentNotifications applicable to the HighAvailability feature have this OID prefix.
1.3.6.1.4.1.6876.120.1.0.21.0IdentityvmwNsxTHighAvailabilityFeaturecurrentSub-identifier added to ensure the next-to-last sub-identifier is zero for HighAvailability feature notifications.
1.3.6.1.4.1.6876.120.1.0.21.0.9NotificationvmwNsxTHighAvailabilityTier0GatewayFailovercurrentThe tier0 gateway vmwNsxTDataCenterEntityId failover from vmwNsxTDataCenterPreviousGatewayState to vmwNsxTDataCenterCurrentGatewayState, service-router vmwNsxT…
1.3.6.1.4.1.6876.120.1.0.21.0.10NotificationvmwNsxTHighAvailabilityTier0GatewayFailoverClearcurrentThe tier0 gateway vmwNsxTDataCenterEntityId is now up. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.21.0.11NotificationvmwNsxTHighAvailabilityTier1GatewayFailovercurrentThe tier1 gateway vmwNsxTDataCenterEntityId failover from vmwNsxTDataCenterPreviousGatewayState to vmwNsxTDataCenterCurrentGatewayState, service-router vmwNsxT…
1.3.6.1.4.1.6876.120.1.0.21.0.12NotificationvmwNsxTHighAvailabilityTier1GatewayFailoverClearcurrentThe tier1 gateway vmwNsxTDataCenterEntityId is now up. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.21.0.13NotificationvmwNsxTHighAvailabilityTier0ServiceGroupFailovercurrentService-group cluster vmwNsxTDataCenterEntityId currently does not have an active instance. It is in state vmwNsxTDataCenterHaState (where 0 is down, 1 is stan…
1.3.6.1.4.1.6876.120.1.0.21.0.14NotificationvmwNsxTHighAvailabilityTier0ServiceGroupFailoverClearcurrentTier0 service-group cluster vmwNsxTDataCenterEntityId now has one active instance on Edge node vmwNsxTDataCenterTransportNodeId. Action required: None, receipt…
1.3.6.1.4.1.6876.120.1.0.21.0.15NotificationvmwNsxTHighAvailabilityTier1ServiceGroupFailovercurrentService-group cluster vmwNsxTDataCenterEntityId currently does not have an active instance. It is in state vmwNsxTDataCenterHaState (where 0 is down, 1 is stan…
1.3.6.1.4.1.6876.120.1.0.21.0.16NotificationvmwNsxTHighAvailabilityTier1ServiceGroupFailoverClearcurrentTier1 service-group cluster vmwNsxTDataCenterEntityId now has one active instance on Edge node vmwNsxTDataCenterTransportNodeId. Action required: None, receipt…
1.3.6.1.4.1.6876.120.1.0.21.0.17NotificationvmwNsxTHighAvailabilityTier0ServiceGroupReducedRedundancycurrentService-group cluster vmwNsxTDataCenterEntityId attached to Tier0 service-router vmwNsxTDataCenterServiceRouterId on Edge node vmwNsxTDataCenterTransportNodeId…
1.3.6.1.4.1.6876.120.1.0.21.0.18NotificationvmwNsxTHighAvailabilityTier0ServiceGroupReducedRedundancyClearcurrentService-group cluster vmwNsxTDataCenterEntityId is in state vmwNsxTDataCenterHaState (where 0 is down, 1 is standby and 2 is active) on Edge node vmwNsxTDataCe…
1.3.6.1.4.1.6876.120.1.0.21.0.19NotificationvmwNsxTHighAvailabilityTier1ServiceGroupReducedRedundancycurrentService-group cluster vmwNsxTDataCenterEntityId attached to Tier1 service-router vmwNsxTDataCenterServiceRouterId on Edge node vmwNsxTDataCenterTransportNodeId…
1.3.6.1.4.1.6876.120.1.0.21.0.20NotificationvmwNsxTHighAvailabilityTier1ServiceGroupReducedRedundancyClearcurrentService-group cluster vmwNsxTDataCenterEntityId is in state vmwNsxTDataCenterHaState (where 0 is down, 1 is standby and 2 is active) on Edge node vmwNsxTDataCe…
1.3.6.1.4.1.6876.120.1.0.22IdentityvmwNsxTCapacityFeaturePrefixcurrentNotifications applicable to the Capacity feature have this OID prefix.
1.3.6.1.4.1.6876.120.1.0.22.0IdentityvmwNsxTCapacityFeaturecurrentSub-identifier added to ensure the next-to-last sub-identifier is zero for Capacity feature notifications.
1.3.6.1.4.1.6876.120.1.0.22.0.1NotificationvmwNsxTCapacityMaximumCapacitycurrentThe number of objects defined in the system for vmwNsxTDataCenterCapacityDisplayName has reached vmwNsxTDataCenterCapacityUsageCount which is above the maximum…
1.3.6.1.4.1.6876.120.1.0.22.0.2NotificationvmwNsxTCapacityMaximumCapacityClearcurrentThe number of objects defined in the system for vmwNsxTDataCenterCapacityDisplayName has reached vmwNsxTDataCenterCapacityUsageCount and is at or below the max…
1.3.6.1.4.1.6876.120.1.0.22.0.3NotificationvmwNsxTCapacityMaximumCapacityThresholdcurrentThe number of objects defined in the system for vmwNsxTDataCenterCapacityDisplayName has reached vmwNsxTDataCenterCapacityUsageCount which is above the maximum…
1.3.6.1.4.1.6876.120.1.0.22.0.4NotificationvmwNsxTCapacityMaximumCapacityThresholdClearcurrentThe number of objects defined in the system for vmwNsxTDataCenterCapacityDisplayName has reached vmwNsxTDataCenterCapacityUsageCount and is at or below the max…
1.3.6.1.4.1.6876.120.1.0.22.0.5NotificationvmwNsxTCapacityMinimumCapacityThresholdcurrentThe number of objects defined in the system for vmwNsxTDataCenterCapacityDisplayName has reached vmwNsxTDataCenterCapacityUsageCount which is above the minimum…
1.3.6.1.4.1.6876.120.1.0.22.0.6NotificationvmwNsxTCapacityMinimumCapacityThresholdClearcurrentThe number of objects defined in the system for vmwNsxTDataCenterCapacityDisplayName has reached vmwNsxTDataCenterCapacityUsageCount and is at or below the min…
1.3.6.1.4.1.6876.120.1.0.24IdentityvmwNsxTAuditLogHealthFeaturePrefixcurrentNotifications applicable to the AuditLogHealth feature have this OID prefix.
1.3.6.1.4.1.6876.120.1.0.24.0IdentityvmwNsxTAuditLogHealthFeaturecurrentSub-identifier added to ensure the next-to-last sub-identifier is zero for AuditLogHealth feature notifications.
1.3.6.1.4.1.6876.120.1.0.24.0.1NotificationvmwNsxTAuditLogHealthAuditLogFileUpdateErrorcurrentAt least one of the monitored log files has read-only permissions or has incorrect user/group ownership on Manager, Global Manager, Edge, Public Cloud Gateway,…
1.3.6.1.4.1.6876.120.1.0.24.0.2NotificationvmwNsxTAuditLogHealthAuditLogFileUpdateErrorClearcurrentAll monitored log files have the correct file permissions and ownership and rsyslog.log exists on Manager, Global Manager, Edge or Public Cloud Gateway nodes. …
1.3.6.1.4.1.6876.120.1.0.24.0.3NotificationvmwNsxTAuditLogHealthRemoteLoggingServerErrorcurrentLog messages to logging server vmwNsxTDataCenterHostnameOrIPAddressWithPort (vmwNsxTDataCenterEntityId) cannot be delivered possibly due to an unresolvable FQD…
1.3.6.1.4.1.6876.120.1.0.24.0.4NotificationvmwNsxTAuditLogHealthRemoteLoggingServerErrorClearcurrentConfiguration for logging server vmwNsxTDataCenterHostnameOrIPAddressWithPort (vmwNsxTDataCenterEntityId) appear correct. Action required: None, receipt of thi…
1.3.6.1.4.1.6876.120.1.0.28IdentityvmwNsxTRoutingFeaturePrefixcurrentNotifications applicable to the Routing feature have this OID prefix.
1.3.6.1.4.1.6876.120.1.0.28.0IdentityvmwNsxTRoutingFeaturecurrentSub-identifier added to ensure the next-to-last sub-identifier is zero for Routing feature notifications.
1.3.6.1.4.1.6876.120.1.0.28.0.1NotificationvmwNsxTRoutingBGPDowncurrentIn Router vmwNsxTDataCenterLrId, BGP neighbor vmwNsxTDataCenterEntityId (vmwNsxTDataCenterBGPNeighborIP) is down. Reason: vmwNsxTDataCenterFailureReason. Actio…
1.3.6.1.4.1.6876.120.1.0.28.0.2NotificationvmwNsxTRoutingBGPDownClearcurrentIn Router vmwNsxTDataCenterLrId, BGP neighbor vmwNsxTDataCenterEntityId (vmwNsxTDataCenterBGPNeighborIP) is up. Action required: None, receipt of this notifica…
1.3.6.1.4.1.6876.120.1.0.28.0.5NotificationvmwNsxTRoutingStaticRoutingRemovedcurrentIn router vmwNsxTDataCenterLrId, static route vmwNsxTDataCenterEntityId (vmwNsxTDataCenterStaticAddress) was removed because BFD was down. Action required: The…
1.3.6.1.4.1.6876.120.1.0.28.0.6NotificationvmwNsxTRoutingStaticRoutingRemovedClearcurrentIn router vmwNsxTDataCenterLrId, static route vmwNsxTDataCenterEntityId (vmwNsxTDataCenterStaticAddress) was re-added as BFD recovered. Action required: None, …
1.3.6.1.4.1.6876.120.1.0.28.0.7NotificationvmwNsxTRoutingBFDDownOnExternalInterfacecurrentIn router vmwNsxTDataCenterLrId, BFD session for peer vmwNsxTDataCenterPeerAddress is down. Action required: 1. Invoke the NSX CLI command `get logical-routers…
1.3.6.1.4.1.6876.120.1.0.28.0.8NotificationvmwNsxTRoutingBFDDownOnExternalInterfaceClearcurrentIn router vmwNsxTDataCenterLrId, BFD session for peer vmwNsxTDataCenterPeerAddress is up. Action required: None, receipt of this notification indicates event c…
1.3.6.1.4.1.6876.120.1.0.28.0.9NotificationvmwNsxTRoutingRoutingDowncurrentAll BGP/BFD sessions are down. Action required: Invoke the NSX CLI command `get logical-routers` to get the tier0 service router and switch to this vrf, then i…
1.3.6.1.4.1.6876.120.1.0.28.0.10NotificationvmwNsxTRoutingRoutingDownClearcurrentAt least one BGP/BFD session up. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.28.0.11NotificationvmwNsxTRoutingOSPFNeighborWentDowncurrentOSPF neighbor vmwNsxTDataCenterPeerAddress moved from full to another state. Action required: 1. Invoke the NSX CLI command `get logical-routers` to get the vr…
1.3.6.1.4.1.6876.120.1.0.28.0.12NotificationvmwNsxTRoutingOSPFNeighborWentDownClearcurrentOSPF neighbor vmwNsxTDataCenterPeerAddress moved to full state. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.28.0.13NotificationvmwNsxTRoutingProxyARPNotConfiguredForServiceIPcurrentProxy ARP for Service IP vmwNsxTDataCenterServiceIP and Service entity vmwNsxTDataCenterEntityId is not configured as the number of ARP proxy entries generated…
1.3.6.1.4.1.6876.120.1.0.28.0.14NotificationvmwNsxTRoutingProxyARPNotConfiguredForServiceIPClearcurrentProxy ARP for Service entity vmwNsxTDataCenterEntityId is generated successfully as the overlap of service IP with subnet of lrport vmwNsxTDataCenterLrportId o…
1.3.6.1.4.1.6876.120.1.0.28.0.39NotificationvmwNsxTRoutingMaximumIPv4PrefixesFromBGPNeighborApproachingcurrentNumber of IPv4 vmwNsxTDataCenterSubsequentAddressFamily prefixes received from vmwNsxTDataCenterBGPNeighborIP reaches vmwNsxTDataCenterPrefixesCountThreshold. …
1.3.6.1.4.1.6876.120.1.0.28.0.40NotificationvmwNsxTRoutingMaximumIPv4PrefixesFromBGPNeighborApproachingClearcurrentNumber of IPv4 vmwNsxTDataCenterSubsequentAddressFamily prefixes received from vmwNsxTDataCenterBGPNeighborIP is within the limit vmwNsxTDataCenterPrefixesCoun…
1.3.6.1.4.1.6876.120.1.0.28.0.41NotificationvmwNsxTRoutingMaximumIPv4PrefixesFromBGPNeighborExceededcurrentNumber of IPv4 vmwNsxTDataCenterSubsequentAddressFamily prefixes received from vmwNsxTDataCenterBGPNeighborIP exceeded the limit defined for this peer of vmwNs…
1.3.6.1.4.1.6876.120.1.0.28.0.42NotificationvmwNsxTRoutingMaximumIPv4PrefixesFromBGPNeighborExceededClearcurrentNumber of IPv4 vmwNsxTDataCenterSubsequentAddressFamily prefixes received from vmwNsxTDataCenterBGPNeighborIP is within the limit vmwNsxTDataCenterPrefixesCoun…
1.3.6.1.4.1.6876.120.1.0.28.0.43NotificationvmwNsxTRoutingMaximumIPv4RouteLimitApproachingcurrentIPv4 routes limit has reached vmwNsxTDataCenterRouteLimitThreshold on Tier0 Gateway and all Tier0 VRFs on Edge node vmwNsxTDataCenterEdgeNode. Action required:…
1.3.6.1.4.1.6876.120.1.0.28.0.44NotificationvmwNsxTRoutingMaximumIPv4RouteLimitApproachingClearcurrentIPv4 routes are within the limit of vmwNsxTDataCenterRouteLimitThreshold on Tier0 Gateway and all Tier0 VRFs on Edge node vmwNsxTDataCenterEdgeNode. Action req…
1.3.6.1.4.1.6876.120.1.0.28.0.45NotificationvmwNsxTRoutingMaximumIPv4RouteLimitExceededcurrentIPv4 routes has exceeded limit of vmwNsxTDataCenterRouteLimitMaximum on Tier0 Gateway and all Tier0 VRFs on Edge node vmwNsxTDataCenterEdgeNode. Action require…
1.3.6.1.4.1.6876.120.1.0.28.0.46NotificationvmwNsxTRoutingMaximumIPv4RouteLimitExceededClearcurrentIPv4 routes are within the limit of vmwNsxTDataCenterRouteLimitMaximum on Tier0 Gateway and all Tier0 VRFs on Edge node vmwNsxTDataCenterEdgeNode. Action requi…
1.3.6.1.4.1.6876.120.1.0.28.0.47NotificationvmwNsxTRoutingMaximumIPv6PrefixesFromBGPNeighborApproachingcurrentNumber of IPv6 vmwNsxTDataCenterSubsequentAddressFamily prefixes received from vmwNsxTDataCenterBGPNeighborIP reaches vmwNsxTDataCenterPrefixesCountThreshold. …
1.3.6.1.4.1.6876.120.1.0.28.0.48NotificationvmwNsxTRoutingMaximumIPv6PrefixesFromBGPNeighborApproachingClearcurrentNumber of IPv6 vmwNsxTDataCenterSubsequentAddressFamily prefixes received from vmwNsxTDataCenterBGPNeighborIP is within the limit vmwNsxTDataCenterPrefixesCoun…
1.3.6.1.4.1.6876.120.1.0.28.0.49NotificationvmwNsxTRoutingMaximumIPv6PrefixesFromBGPNeighborExceededcurrentNumber of IPv6 vmwNsxTDataCenterSubsequentAddressFamily prefixes received from vmwNsxTDataCenterBGPNeighborIP exceeded the limit defined for this peer of vmwNs…
1.3.6.1.4.1.6876.120.1.0.28.0.50NotificationvmwNsxTRoutingMaximumIPv6PrefixesFromBGPNeighborExceededClearcurrentNumber of IPv6 vmwNsxTDataCenterSubsequentAddressFamily prefixes received from vmwNsxTDataCenterBGPNeighborIP is within the limit vmwNsxTDataCenterPrefixesCoun…
1.3.6.1.4.1.6876.120.1.0.28.0.51NotificationvmwNsxTRoutingMaximumIPv6RouteLimitApproachingcurrentIPv6 routes limit has reached vmwNsxTDataCenterRouteLimitThreshold on Tier0 Gateway and all Tier0 VRFs on Edge node vmwNsxTDataCenterEdgeNode. Action required:…
1.3.6.1.4.1.6876.120.1.0.28.0.52NotificationvmwNsxTRoutingMaximumIPv6RouteLimitApproachingClearcurrentIPv6 routes are within the limit of vmwNsxTDataCenterRouteLimitThreshold on Tier0 Gateway and all Tier0 VRFs on Edge node vmwNsxTDataCenterEdgeNode. Action req…
1.3.6.1.4.1.6876.120.1.0.28.0.53NotificationvmwNsxTRoutingMaximumIPv6RouteLimitExceededcurrentIPv6 routes has exceeded limit of vmwNsxTDataCenterRouteLimitMaximum on Tier0 Gateway and all Tier0 VRFs on Edge node vmwNsxTDataCenterEdgeNode. Action require…
1.3.6.1.4.1.6876.120.1.0.28.0.54NotificationvmwNsxTRoutingMaximumIPv6RouteLimitExceededClearcurrentIPv6 routes are within the limit of vmwNsxTDataCenterRouteLimitMaximum on Tier0 Gateway and all Tier0 VRFs on Edge node vmwNsxTDataCenterEdgeNode. Action requi…
1.3.6.1.4.1.6876.120.1.0.30IdentityvmwNsxTDNSFeaturePrefixcurrentNotifications applicable to the DNS feature have this OID prefix.
1.3.6.1.4.1.6876.120.1.0.30.0IdentityvmwNsxTDNSFeaturecurrentSub-identifier added to ensure the next-to-last sub-identifier is zero for DNS feature notifications.
1.3.6.1.4.1.6876.120.1.0.30.0.1NotificationvmwNsxTDNSForwarderDisabledcurrentDNS forwarder vmwNsxTDataCenterEntityId is disabled. Action required: 1. Invoke the NSX CLI command `get dns-forwarders status` to verify if the DNS forwarder …
1.3.6.1.4.1.6876.120.1.0.30.0.2NotificationvmwNsxTDNSForwarderDisabledClearcurrentDNS forwarder vmwNsxTDataCenterEntityId is enabled. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.30.0.3NotificationvmwNsxTDNSForwarderDowncurrentDNS forwarder vmwNsxTDataCenterEntityId is not running. This is impacting the identified DNS Forwarder that is currently enabled. Action required: 1. Invoke th…
1.3.6.1.4.1.6876.120.1.0.30.0.4NotificationvmwNsxTDNSForwarderDownClearcurrentDNS forwarder vmwNsxTDataCenterEntityId is running again. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.30.0.5NotificationvmwNsxTDNSForwarderUpstreamServerTimeoutcurrentDNS forwarder vmwNsxTDataCenterIntentPath(vmwNsxTDataCenterDNSId) did not receive a timely response from upstream server vmwNsxTDataCenterDNSUpstreamIP. Comput…
1.3.6.1.4.1.6876.120.1.0.30.0.6NotificationvmwNsxTDNSForwarderUpstreamServerTimeoutClearcurrentDNS forwarder vmwNsxTDataCenterIntentPath(vmwNsxTDataCenterDNSId) upstream server vmwNsxTDataCenterDNSUpstreamIP is normal. Action required: None, receipt of t…
1.3.6.1.4.1.6876.120.1.0.31IdentityvmwNsxTDistributedFirewallFeaturePrefixcurrentNotifications applicable to the DistributedFirewall feature have this OID prefix.
1.3.6.1.4.1.6876.120.1.0.31.0IdentityvmwNsxTDistributedFirewallFeaturecurrentSub-identifier added to ensure the next-to-last sub-identifier is zero for DistributedFirewall feature notifications.
1.3.6.1.4.1.6876.120.1.0.31.0.1NotificationvmwNsxTDistributedFirewallDFWCPUUsageVeryHighcurrentThe DFW CPU usage on Transport node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above the very high threshold va…
1.3.6.1.4.1.6876.120.1.0.31.0.2NotificationvmwNsxTDistributedFirewallDFWCPUUsageVeryHighClearcurrentThe DFW CPU usage on Transport node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which is below the very high threshold value of…
1.3.6.1.4.1.6876.120.1.0.31.0.3NotificationvmwNsxTDistributedFirewallDFWMemoryUsageVeryHighcurrentThe DFW Memory usage vmwNsxTDataCenterHeapType on Transport node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which is at or abo…
1.3.6.1.4.1.6876.120.1.0.31.0.4NotificationvmwNsxTDistributedFirewallDFWMemoryUsageVeryHighClearcurrentThe DFW Memory usage vmwNsxTDataCenterHeapType on Transport node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which is below the…
1.3.6.1.4.1.6876.120.1.0.31.0.5NotificationvmwNsxTDistributedFirewallDFWSessionCountHighcurrentThe DFW session count is high on Transport node vmwNsxTDataCenterEntityId, it has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above the thresh…
1.3.6.1.4.1.6876.120.1.0.31.0.6NotificationvmwNsxTDistributedFirewallDFWSessionCountHighClearcurrentThe DFW session count on Transport node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which is below the the threshold value of v…
1.3.6.1.4.1.6876.120.1.0.31.0.7NotificationvmwNsxTDistributedFirewallDFWVmotionFailurecurrentThe DFW vMotion for DFW filter vmwNsxTDataCenterEntityId on destination host vmwNsxTDataCenterTransportNodeName has failed and the port for the entity has been…
1.3.6.1.4.1.6876.120.1.0.31.0.8NotificationvmwNsxTDistributedFirewallDFWVmotionFailureClearcurrentThe DFW configuration for DFW filter vmwNsxTDataCenterEntityId on the destination host vmwNsxTDataCenterTransportNodeName has succeeded and error caused by DFW…
1.3.6.1.4.1.6876.120.1.0.31.0.9NotificationvmwNsxTDistributedFirewallDFWRulesLimitPervNICExceededcurrentThe DFW rules limit for VIF vmwNsxTDataCenterEntityId on destination host vmwNsxTDataCenterTransportNodeName is about to exceed the maximum limit. Action requi…
1.3.6.1.4.1.6876.120.1.0.31.0.10NotificationvmwNsxTDistributedFirewallDFWRulesLimitPervNICExceededClearcurrentThe DFW rules limit for VIF vmwNsxTDataCenterEntityId on the destination host vmwNsxTDataCenterTransportNodeName dropped below maximum limit. Action required: …
1.3.6.1.4.1.6876.120.1.0.31.0.11NotificationvmwNsxTDistributedFirewallDFWRulesLimitPerHostApproachingcurrentThe DFW rules limit for host vmwNsxTDataCenterTransportNodeName is approaching the maximum limit. Action required: Log in into the ESX host vmwNsxTDataCenterTr…
1.3.6.1.4.1.6876.120.1.0.31.0.12NotificationvmwNsxTDistributedFirewallDFWRulesLimitPerHostApproachingClearcurrentThe DFW rules limit for host vmwNsxTDataCenterTransportNodeName dropped below the threshold. Action required: None, receipt of this notification indicates even…
1.3.6.1.4.1.6876.120.1.0.31.0.13NotificationvmwNsxTDistributedFirewallDFWRulesLimitPerHostExceededcurrentThe DFW rules limit for host vmwNsxTDataCenterTransportNodeName is about to exceed the maximum limit. Action required: Log in into the ESX host vmwNsxTDataCent…
1.3.6.1.4.1.6876.120.1.0.31.0.14NotificationvmwNsxTDistributedFirewallDFWRulesLimitPerHostExceededClearcurrentThe DFW rules limit for host vmwNsxTDataCenterTransportNodeName dropped below maximum limit. Action required: None, receipt of this notification indicates even…
1.3.6.1.4.1.6876.120.1.0.31.0.15NotificationvmwNsxTDistributedFirewallDFWRulesLimitPervNICApproachingcurrentThe DFW rules limit for VIF vmwNsxTDataCenterEntityId on destination host vmwNsxTDataCenterTransportNodeName is approaching the maximum limit. Action required:…
1.3.6.1.4.1.6876.120.1.0.31.0.16NotificationvmwNsxTDistributedFirewallDFWRulesLimitPervNICApproachingClearcurrentThe DFW rules limit for VIF vmwNsxTDataCenterEntityId on the destination host vmwNsxTDataCenterTransportNodeName dropped below the threshold. Action required: …
1.3.6.1.4.1.6876.120.1.0.31.0.17NotificationvmwNsxTDistributedFirewallDFWCPUUsageVeryHighOnDPUcurrentThe DFW CPU usage on Transport node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% on DPU vmwNsxTDataCenterDPUId which is at or ab…
1.3.6.1.4.1.6876.120.1.0.31.0.18NotificationvmwNsxTDistributedFirewallDFWCPUUsageVeryHighOnDPUClearcurrentThe DFW CPU usage on Transport node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% on DPU vmwNsxTDataCenterDPUId which is below th…
1.3.6.1.4.1.6876.120.1.0.31.0.19NotificationvmwNsxTDistributedFirewallDFWMemoryUsageVeryHighOnDPUcurrentThe DFW Memory usage vmwNsxTDataCenterHeapType on Transport node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% on DPU vmwNsxTData…
1.3.6.1.4.1.6876.120.1.0.31.0.20NotificationvmwNsxTDistributedFirewallDFWMemoryUsageVeryHighOnDPUClearcurrentThe DFW Memory usage vmwNsxTDataCenterHeapType on Transport node vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% on DPU vmwNsxTData…
1.3.6.1.4.1.6876.120.1.0.31.0.21NotificationvmwNsxTDistributedFirewallDFWFloodLimitWarningcurrentThe DFW flood limit for DFW filter vmwNsxTDataCenterEntityId on host vmwNsxTDataCenterTransportNodeName has reached warning level of 80% of the configured limi…
1.3.6.1.4.1.6876.120.1.0.31.0.22NotificationvmwNsxTDistributedFirewallDFWFloodLimitWarningClearcurrentThe warning flood limit condition for DFW filter vmwNsxTDataCenterEntityId on host vmwNsxTDataCenterTransportNodeName for protocol vmwNsxTDataCenterProtocolNam…
1.3.6.1.4.1.6876.120.1.0.31.0.23NotificationvmwNsxTDistributedFirewallDFWFloodLimitCriticalcurrentThe DFW flood limit for DFW filter vmwNsxTDataCenterEntityId on host vmwNsxTDataCenterTransportNodeName has reached critical level of 98% of the configured lim…
1.3.6.1.4.1.6876.120.1.0.31.0.24NotificationvmwNsxTDistributedFirewallDFWFloodLimitCriticalClearcurrentThe critical flood limit condition for DFW filter vmwNsxTDataCenterEntityId on host vmwNsxTDataCenterTransportNodeName for protocol vmwNsxTDataCenterProtocolNa…
1.3.6.1.4.1.6876.120.1.0.32IdentityvmwNsxTFederationFeaturePrefixcurrentNotifications applicable to the Federation feature have this OID prefix.
1.3.6.1.4.1.6876.120.1.0.32.0IdentityvmwNsxTFederationFeaturecurrentSub-identifier added to ensure the next-to-last sub-identifier is zero for Federation feature notifications.
1.3.6.1.4.1.6876.120.1.0.32.0.1NotificationvmwNsxTFederationRtepBGPDowncurrentRTEP (Remote Tunnel Endpoint) BGP session from source IP vmwNsxTDataCenterBGPSourceIP to remote location vmwNsxTDataCenterRemoteSiteName neighbor IP vmwNsxTDat…
1.3.6.1.4.1.6876.120.1.0.32.0.2NotificationvmwNsxTFederationRtepBGPDownClearcurrentRTEP (Remote Tunnel Endpoint) BGP session from source IP vmwNsxTDataCenterBGPSourceIP to remote location vmwNsxTDataCenterRemoteSiteName neighbor IP vmwNsxTDat…
1.3.6.1.4.1.6876.120.1.0.32.0.3NotificationvmwNsxTFederationLmToLmSynchronizationErrorcurrentThe synchronization between vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) failed for mo…
1.3.6.1.4.1.6876.120.1.0.32.0.4NotificationvmwNsxTFederationLmToLmSynchronizationErrorClearcurrentRemote sites vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) are now synchronized. Action…
1.3.6.1.4.1.6876.120.1.0.32.0.5NotificationvmwNsxTFederationLmToLmSynchronizationWarningcurrentThe synchronization between vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) failed for mo…
1.3.6.1.4.1.6876.120.1.0.32.0.6NotificationvmwNsxTFederationLmToLmSynchronizationWarningClearcurrentRemote locations vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) are now synchronized. Ac…
1.3.6.1.4.1.6876.120.1.0.32.0.7NotificationvmwNsxTFederationRtepConnectivityLostcurrentEdge node vmwNsxTDataCenterTransportNodeName lost RTEP (Remote Tunnel Endpoint) connectivity with remote location vmwNsxTDataCenterRemoteSiteName. Action requi…
1.3.6.1.4.1.6876.120.1.0.32.0.8NotificationvmwNsxTFederationRtepConnectivityLostClearcurrentEdge node vmwNsxTDataCenterTransportNodeName has restored RTEP (Remote Tunnel Endpoint) connectivity with remote location vmwNsxTDataCenterRemoteSiteName. Acti…
1.3.6.1.4.1.6876.120.1.0.32.0.9NotificationvmwNsxTFederationGMToGMSplitBraincurrentMultiple Global Manager nodes are active: vmwNsxTDataCenterActiveGlobalManagers. Only one Global Manager node must be active at any time. Action required: Conf…
1.3.6.1.4.1.6876.120.1.0.32.0.10NotificationvmwNsxTFederationGMToGMSplitBrainClearcurrentGlobal Manager node vmwNsxTDataCenterActiveGlobalManager is the only active Global Manager node now. Action required: None, receipt of this notification indica…
1.3.6.1.4.1.6876.120.1.0.32.0.17NotificationvmwNsxTFederationGMToGMLatencyWarningcurrentLatency is higher than expected between Global Managers vmwNsxTDataCenterFromGMPath and vmwNsxTDataCenterToGMPath. Action required: Check the connectivity from…
1.3.6.1.4.1.6876.120.1.0.32.0.18NotificationvmwNsxTFederationGMToGMLatencyWarningClearcurrentLatency is below expected levels between Global Managers vmwNsxTDataCenterFromGMPath and vmwNsxTDataCenterToGMPath. Action required: None, receipt of this noti…
1.3.6.1.4.1.6876.120.1.0.32.0.19NotificationvmwNsxTFederationGMToGMSynchronizationErrorcurrentActive Global Manager vmwNsxTDataCenterFromGMPath to Standby Global Manager vmwNsxTDataCenterToGMPath cannot synchronize for more than 5 minutes. Action requir…
1.3.6.1.4.1.6876.120.1.0.32.0.20NotificationvmwNsxTFederationGMToGMSynchronizationErrorClearcurrentSynchronization from active Global Manager vmwNsxTDataCenterFromGMPath to standby vmwNsxTDataCenterToGMPath is healthy. Action required: None, receipt of this …
1.3.6.1.4.1.6876.120.1.0.32.0.21NotificationvmwNsxTFederationGMToGMSynchronizationWarningcurrentActive Global Manager vmwNsxTDataCenterFromGMPath to Standby Global Manager vmwNsxTDataCenterToGMPath can not synchronize. Action required: Check the connectiv…
1.3.6.1.4.1.6876.120.1.0.32.0.22NotificationvmwNsxTFederationGMToGMSynchronizationWarningClearcurrentSynchronization from active Global Manager vmwNsxTDataCenterFromGMPath to standby vmwNsxTDataCenterToGMPath is healthy. Action required: None, receipt of this …
1.3.6.1.4.1.6876.120.1.0.32.0.23NotificationvmwNsxTFederationGMToLMSynchronizationErrorcurrentData synchronization between sites vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) failed…
1.3.6.1.4.1.6876.120.1.0.32.0.24NotificationvmwNsxTFederationGMToLMSynchronizationErrorClearcurrentSites vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) are now synchronized for vmwNsxTDat…
1.3.6.1.4.1.6876.120.1.0.32.0.25NotificationvmwNsxTFederationGMToLMSynchronizationWarningcurrentData synchronization between sites vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) failed…
1.3.6.1.4.1.6876.120.1.0.32.0.26NotificationvmwNsxTFederationGMToLMSynchronizationWarningClearcurrentSites vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) are now synchronized for vmwNsxTDat…
1.3.6.1.4.1.6876.120.1.0.32.0.27NotificationvmwNsxTFederationGMToLMLatencyWarningcurrentLatency between sites vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) has reached vmwNsxT…
1.3.6.1.4.1.6876.120.1.0.32.0.28NotificationvmwNsxTFederationGMToLMLatencyWarningClearcurrentLatency between sites vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) has reached vmwNsxT…
1.3.6.1.4.1.6876.120.1.0.32.0.29NotificationvmwNsxTFederationQueueOccupancyThresholdExceededcurrentQueue (vmwNsxTDataCenterQueueName) used for syncing data between sites vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(v…
1.3.6.1.4.1.6876.120.1.0.32.0.30NotificationvmwNsxTFederationQueueOccupancyThresholdExceededClearcurrentQueue (vmwNsxTDataCenterQueueName) used for syncing data between sites vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(v…
1.3.6.1.4.1.6876.120.1.0.32.0.31NotificationvmwNsxTFederationLMRestoreWhileConfigImportInProgresscurrentConfig import from site vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) is in progress. However site vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) is r…
1.3.6.1.4.1.6876.120.1.0.32.0.32NotificationvmwNsxTFederationLMRestoreWhileConfigImportInProgressClearcurrentConfig inconsistency at site vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) is resolved. Action required: None, receipt of this notification indicates even…
1.3.6.1.4.1.6876.120.1.0.33IdentityvmwNsxTDistributedIDSIPSFeaturePrefixcurrentNotifications applicable to the DistributedIDSIPS feature have this OID prefix.
1.3.6.1.4.1.6876.120.1.0.33.0IdentityvmwNsxTDistributedIDSIPSFeaturecurrentSub-identifier added to ensure the next-to-last sub-identifier is zero for DistributedIDSIPS feature notifications.
1.3.6.1.4.1.6876.120.1.0.33.0.3NotificationvmwNsxTDistributedIDSIPSMaxEventsReachedcurrentThe number of intrusion events in the system is vmwNsxTDataCenterIDSEventsCount which is higher than the maximum allowed value vmwNsxTDataCenterMaxIDSEventsAll…
1.3.6.1.4.1.6876.120.1.0.33.0.4NotificationvmwNsxTDistributedIDSIPSMaxEventsReachedClearcurrentThe number of intrusion events in the system is vmwNsxTDataCenterIDSEventsCount which is below the maximum allowed value vmwNsxTDataCenterMaxIDSEventsAllowed. …
1.3.6.1.4.1.6876.120.1.0.33.0.7NotificationvmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageHighcurrentNSX-IDPS engine CPU usage has reached vmwNsxTDataCenterSystemResourceUsage%, which is at or above the high threshold value of 75%. Action required: Consider re…
1.3.6.1.4.1.6876.120.1.0.33.0.8NotificationvmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageHighClearcurrentNSX-IDPS engine CPU usage has reached vmwNsxTDataCenterSystemResourceUsage%, which is below the high threshold value of 75%. Action required: None, receipt of …
1.3.6.1.4.1.6876.120.1.0.33.0.9NotificationvmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageVeryHighcurrentNSX-IDPS engine CPU usage has reached vmwNsxTDataCenterSystemResourceUsage%, which is at or above the very high threshold value of 95%. Action required: Consid…
1.3.6.1.4.1.6876.120.1.0.33.0.10NotificationvmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageVeryHighClearcurrentNSX-IDPS engine CPU usage has reached vmwNsxTDataCenterSystemResourceUsage%, which is below the very high threshold value of 95%. Action required: None, receip…
1.3.6.1.4.1.6876.120.1.0.33.0.13NotificationvmwNsxTDistributedIDSIPSNSXIDPSEngineDowncurrentNSX IDPS is enabled via NSX policy and IDPS rules are configured, but NSX-IDPS engine is down. Action required: 1. Check /var/log/nsx-syslog.log to see if ther…
1.3.6.1.4.1.6876.120.1.0.33.0.14NotificationvmwNsxTDistributedIDSIPSNSXIDPSEngineDownClearcurrentNSX IDPS is in one of the cases below. 1. NSX IDPS is disabled via NSX policy. 2. NSX IDPS engine is enabled, NSX-IDPS engine and vdpi are up, and NSX IDPS has…
1.3.6.1.4.1.6876.120.1.0.33.0.15NotificationvmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageHighcurrentNSX-IDPS engine memory usage has reached vmwNsxTDataCenterSystemResourceUsage%, which is at or above the high threshold value of 75%. Action required: Consider…
1.3.6.1.4.1.6876.120.1.0.33.0.16NotificationvmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageHighClearcurrentNSX-IDPS engine memory usage has reached vmwNsxTDataCenterSystemResourceUsage%, which is below the high threshold value of 75%. Action required: None, receipt …
1.3.6.1.4.1.6876.120.1.0.33.0.17NotificationvmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageMediumHighcurrentNSX-IDPS engine memory usage has reached vmwNsxTDataCenterSystemResourceUsage%, which is at or above the medium high threshold value of 85%. Action required: C…
1.3.6.1.4.1.6876.120.1.0.33.0.18NotificationvmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageMediumHighClearcurrentNSX-IDPS engine memory usage has reached vmwNsxTDataCenterSystemResourceUsage%, which is below the medium high threshold value of 85%. Action required: None, r…
1.3.6.1.4.1.6876.120.1.0.33.0.19NotificationvmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageVeryHighcurrentNSX-IDPS engine memory usage has reached vmwNsxTDataCenterSystemResourceUsage%, which is at or above the very high threshold value of 95%. Action required: Con…
1.3.6.1.4.1.6876.120.1.0.33.0.20NotificationvmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageVeryHighClearcurrentNSX-IDPS engine memory usage has reached vmwNsxTDataCenterSystemResourceUsage%, which is below the very high threshold value of 95%. Action required: None, rec…
1.3.6.1.4.1.6876.120.1.0.33.0.21NotificationvmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageMediumHighcurrentNSX-IDPS engine CPU usage has reached vmwNsxTDataCenterSystemResourceUsage%, which is at or above the medium high threshold value of 85%. Action required: Cons…
1.3.6.1.4.1.6876.120.1.0.33.0.22NotificationvmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageMediumHighClearcurrentNSX-IDPS engine CPU usage has reached vmwNsxTDataCenterSystemResourceUsage%, which is below the medium high threshold value of 85%. Action required: None, rece…
1.3.6.1.4.1.6876.120.1.0.33.0.23NotificationvmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageHighOnDPUcurrentNSX-IDPS engine memory usage has reached vmwNsxTDataCenterSystemResourceUsage%, which is at or above the high threshold value of 75% on DPU vmwNsxTDataCenterDP…
1.3.6.1.4.1.6876.120.1.0.33.0.24NotificationvmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageHighOnDPUClearcurrentNSX-IDPS engine memory usage has reached on DPU vmwNsxTDataCenterDPUId, vmwNsxTDataCenterSystemResourceUsage%, which is below the high threshold value of 75%. …
1.3.6.1.4.1.6876.120.1.0.33.0.31NotificationvmwNsxTDistributedIDSIPSNSXIDPSEngineDownOnDPUcurrentNSX IDPS is enabled via NSX policy and IDPS rules are configured, but NSX-IDPS engine is down on DPU vmwNsxTDataCenterDPUId. Action required: 1. Check /var/log…
1.3.6.1.4.1.6876.120.1.0.33.0.32NotificationvmwNsxTDistributedIDSIPSNSXIDPSEngineDownOnDPUClearcurrentNSX IDPS is in one of the cases below on DPU vmwNsxTDataCenterDPUId. 1. NSX IDPS is disabled via NSX policy. 2. NSX IDPS engine is enabled, NSX-IDPS engine and…
1.3.6.1.4.1.6876.120.1.0.33.0.33NotificationvmwNsxTDistributedIDSIPSNSXIDPSEngineMemUsageMedHighOnDPUcurrentNSX-IDPS engine memory usage has reached vmwNsxTDataCenterSystemResourceUsage%, which is at or above the medium high threshold value of 85% on DPU vmwNsxTDataC…
1.3.6.1.4.1.6876.120.1.0.33.0.34NotificationvmwNsxTDistributedIDSIPSNSXIDPSEngineMemUsageMedHighOnDPUClearcurrentNSX-IDPS engine memory usage has reached on DPU vmwNsxTDataCenterDPUId, vmwNsxTDataCenterSystemResourceUsage%, which is below the medium high threshold value o…
1.3.6.1.4.1.6876.120.1.0.33.0.35NotificationvmwNsxTDistributedIDSIPSNSXIDPSEngineMemUsageVeryHighDPUcurrentNSX-IDPS engine memory usage has reached vmwNsxTDataCenterSystemResourceUsage%, which is at or above the very high threshold value of 95% on DPU vmwNsxTDataCen…
1.3.6.1.4.1.6876.120.1.0.33.0.36NotificationvmwNsxTDistributedIDSIPSNSXIDPSEngineMemUsageVeryHighDPUClearcurrentNSX-IDPS engine memory usage has reached on DPU vmwNsxTDataCenterDPUId, vmwNsxTDataCenterSystemResourceUsage%, which is below the very high threshold value of …
1.3.6.1.4.1.6876.120.1.0.33.0.53NotificationvmwNsxTDistributedIDSIPSIDPSBypassedCPUOversubscribedcurrentThe IDPS engine has insufficient CPU resources and is unable to keep pace with the incoming traffic resulting in the excess traffic being bypassed. For more de…
1.3.6.1.4.1.6876.120.1.0.33.0.54NotificationvmwNsxTDistributedIDSIPSIDPSBypassedCPUOversubscribedClearcurrentThe distributed IDPS engine has adequate CPU resources and is not bypassing any traffic. Action required: None, receipt of this notification indicates event cl…
1.3.6.1.4.1.6876.120.1.0.33.0.55NotificationvmwNsxTDistributedIDSIPSIDPSBypassedNetworkOversubscribedcurrentThe IDPS engine is unable to keep pace with the rate of incoming traffic resulting in the excess traffic being bypassed. For more details, login to the ESX hos…
1.3.6.1.4.1.6876.120.1.0.33.0.56NotificationvmwNsxTDistributedIDSIPSIDPSBypassedNetworkOversubscribedClearcurrentThe distributed IDPS engine is not bypassing any traffic. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.33.0.57NotificationvmwNsxTDistributedIDSIPSIDPSEngineCPUOversubscriptionHighcurrentCPU utilization for the distributed IDPS engine is at or above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Review reas…
1.3.6.1.4.1.6876.120.1.0.33.0.58NotificationvmwNsxTDistributedIDSIPSIDPSEngineCPUOversubscriptionHighClearcurrentCPU utilization for the distributed IDPS engine is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of …
1.3.6.1.4.1.6876.120.1.0.33.0.59NotificationvmwNsxTDistributedIDSIPSIDPSCPUOversubscriptionVeryHighcurrentCPU utilization for the distributed IDPS engine is at or above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Review…
1.3.6.1.4.1.6876.120.1.0.33.0.60NotificationvmwNsxTDistributedIDSIPSIDPSCPUOversubscriptionVeryHighClearcurrentCPU utilization for the distributed IDPS engine is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receip…
1.3.6.1.4.1.6876.120.1.0.33.0.61NotificationvmwNsxTDistributedIDSIPSIDPSDroppedCPUOversubscribedcurrentThe IDPS engine has insufficient CPU resources and is unable to keep pace with the incoming traffic resulting in the excess traffic being dropped. For more det…
1.3.6.1.4.1.6876.120.1.0.33.0.62NotificationvmwNsxTDistributedIDSIPSIDPSDroppedCPUOversubscribedClearcurrentThe distributed IDPS engine has adequate CPU resources and is not dropping any traffic. Action required: None, receipt of this notification indicates event cle…
1.3.6.1.4.1.6876.120.1.0.33.0.63NotificationvmwNsxTDistributedIDSIPSIDPSDroppedNetworkOversubscribedcurrentThe IDPS engine is unable to keep pace with the rate of incoming traffic resulting in the excess traffic being dropped. For more details, login to the ESX host…
1.3.6.1.4.1.6876.120.1.0.33.0.64NotificationvmwNsxTDistributedIDSIPSIDPSDroppedNetworkOversubscribedClearcurrentThe distributed IDPS engine is not dropping any traffic. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.33.0.65NotificationvmwNsxTDistributedIDSIPSIDPSNetworkOversubscriptionHighcurrentNetwork utilization for the distributed IDPS engine is at or above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Review …
1.3.6.1.4.1.6876.120.1.0.33.0.66NotificationvmwNsxTDistributedIDSIPSIDPSNetworkOversubscriptionHighClearcurrentNetwork utilization for the distributed IDPS engine is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt…
1.3.6.1.4.1.6876.120.1.0.33.0.67NotificationvmwNsxTDistributedIDSIPSIDPSNetworkOversubscriptionVeryHighcurrentNetwork utilization for the distributed IDPS engine is at or above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Re…
1.3.6.1.4.1.6876.120.1.0.33.0.68NotificationvmwNsxTDistributedIDSIPSIDPSNetworkOversubscriptionVeryHighClearcurrentNetwork utilization for the distributed IDPS engine is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, re…
1.3.6.1.4.1.6876.120.1.0.35IdentityvmwNsxTCommunicationFeaturePrefixcurrentNotifications applicable to the Communication feature have this OID prefix.
1.3.6.1.4.1.6876.120.1.0.35.0IdentityvmwNsxTCommunicationFeaturecurrentSub-identifier added to ensure the next-to-last sub-identifier is zero for Communication feature notifications.
1.3.6.1.4.1.6876.120.1.0.35.0.1NotificationvmwNsxTCommunicationManagementChannelToTransportNodeDowncurrentManagement channel to Transport Node vmwNsxTDataCenterTransportNodeName (vmwNsxTDataCenterTransportNodeAddress) is down for 5 minutes. Action required: Ensure …
1.3.6.1.4.1.6876.120.1.0.35.0.2NotificationvmwNsxTCommunicationManagementChannelToTransportNodeDownClearcurrentManagement channel to Transport Node vmwNsxTDataCenterTransportNodeName (vmwNsxTDataCenterTransportNodeAddress) is up. Action required: None, receipt of this n…
1.3.6.1.4.1.6876.120.1.0.35.0.3NotificationvmwNsxTCommunicationManagerControlChannelDowncurrentThe communication between the management function and the control function has failed on Manager node vmwNsxTDataCenterManagerNodeName (vmwNsxTDataCenterApplia…
1.3.6.1.4.1.6876.120.1.0.35.0.4NotificationvmwNsxTCommunicationManagerControlChannelDownClearcurrentThe communication between the management function and the control function has been restored on Manager node vmwNsxTDataCenterManagerNodeName (vmwNsxTDataCente…
1.3.6.1.4.1.6876.120.1.0.35.0.5NotificationvmwNsxTCommunicationManagementChannelToTransportNodeDownLgcurrentManagement channel to Transport Node vmwNsxTDataCenterTransportNodeName (vmwNsxTDataCenterTransportNodeAddress) is down for 15 minutes. Action required: Ensure…
1.3.6.1.4.1.6876.120.1.0.35.0.6NotificationvmwNsxTCommunicationManagementChannelToTransportNodeDownLgClearcurrentManagement channel to Transport Node vmwNsxTDataCenterTransportNodeName (vmwNsxTDataCenterTransportNodeAddress) is up. Action required: None, receipt of this n…
1.3.6.1.4.1.6876.120.1.0.35.0.7NotificationvmwNsxTCommunicationControlChannelToManagerNodeDowncurrentThe Transport node vmwNsxTDataCenterEntityId control plane connection to Manager node vmwNsxTDataCenterApplianceAddress is down for at least vmwNsxTDataCenterT…
1.3.6.1.4.1.6876.120.1.0.35.0.8NotificationvmwNsxTCommunicationControlChannelToManagerNodeDownClearcurrentThe Transport node vmwNsxTDataCenterEntityId restores the control plane connection to Manager node vmwNsxTDataCenterApplianceAddress. Action required: None, re…
1.3.6.1.4.1.6876.120.1.0.35.0.9NotificationvmwNsxTCommunicationControlChannelToManagerNodeDownTooLongcurrentThe Transport node vmwNsxTDataCenterEntityId control plane connection to Manager node vmwNsxTDataCenterApplianceAddress is down for at least vmwNsxTDataCenterT…
1.3.6.1.4.1.6876.120.1.0.35.0.10NotificationvmwNsxTCommunicationControlChannelToManagerNodeDownTooLongClearcurrentThe Transport node vmwNsxTDataCenterEntityId restores the control plane connection to Manager node vmwNsxTDataCenterApplianceAddress. Action required: None, re…
1.3.6.1.4.1.6876.120.1.0.35.0.11NotificationvmwNsxTCommunicationControlChannelToTransportNodeDowncurrentController service on Manager node vmwNsxTDataCenterApplianceAddress (vmwNsxTDataCenterCentralControlPlaneId) to Transport node vmwNsxTDataCenterTransportNodeN…
1.3.6.1.4.1.6876.120.1.0.35.0.12NotificationvmwNsxTCommunicationControlChannelToTransportNodeDownClearcurrentController service on Manager node vmwNsxTDataCenterApplianceAddress (vmwNsxTDataCenterCentralControlPlaneId) restores connection to Transport node vmwNsxTData…
1.3.6.1.4.1.6876.120.1.0.35.0.13NotificationvmwNsxTCommunicationManagementChannelToManagerNodeDowncurrentManagement channel to Manager Node vmwNsxTDataCenterManagerNodeId (vmwNsxTDataCenterApplianceAddress) is down for 5 minutes. Action required: Ensure there is n…
1.3.6.1.4.1.6876.120.1.0.35.0.14NotificationvmwNsxTCommunicationManagementChannelToManagerNodeDownClearcurrentManagement channel to Manager Node vmwNsxTDataCenterManagerNodeId (vmwNsxTDataCenterApplianceAddress) is up. Action required: None, receipt of this notificatio…
1.3.6.1.4.1.6876.120.1.0.35.0.17NotificationvmwNsxTCommunicationManagerClusterLatencyHighcurrentThe average network latency between Manager nodes vmwNsxTDataCenterManagerNodeId (vmwNsxTDataCenterApplianceAddress) and vmwNsxTDataCenterRemoteManagerNodeId (…
1.3.6.1.4.1.6876.120.1.0.35.0.18NotificationvmwNsxTCommunicationManagerClusterLatencyHighClearcurrentThe average network latency between Manager nodes vmwNsxTDataCenterManagerNodeId (vmwNsxTDataCenterApplianceAddress) and vmwNsxTDataCenterRemoteManagerNodeId (…
1.3.6.1.4.1.6876.120.1.0.35.0.19NotificationvmwNsxTCommunicationControlChannelToTransportNodeDownLongcurrentController service on Manager node vmwNsxTDataCenterApplianceAddress (vmwNsxTDataCenterCentralControlPlaneId) to Transport node vmwNsxTDataCenterTransportNodeN…
1.3.6.1.4.1.6876.120.1.0.35.0.20NotificationvmwNsxTCommunicationControlChannelToTransportNodeDownLongClearcurrentController service on Manager node vmwNsxTDataCenterApplianceAddress (vmwNsxTDataCenterCentralControlPlaneId) restores connection to Transport node vmwNsxTData…
1.3.6.1.4.1.6876.120.1.0.35.0.21NotificationvmwNsxTCommunicationManagerFQDNLookupFailurecurrentDNS lookup failed for Manager node vmwNsxTDataCenterEntityId with FQDN vmwNsxTDataCenterApplianceFQDN and the publish_fqdns flag was set. Action required: 1. A…
1.3.6.1.4.1.6876.120.1.0.35.0.22NotificationvmwNsxTCommunicationManagerFQDNLookupFailureClearcurrentFQDN lookup succeeded for Manager node vmwNsxTDataCenterEntityId with FQDN vmwNsxTDataCenterApplianceFQDN or the publish_fqdns flag was cleared. Action require…
1.3.6.1.4.1.6876.120.1.0.35.0.23NotificationvmwNsxTCommunicationManagerFQDNReverseLookupFailurecurrentReverse DNS lookup failed for Manager node vmwNsxTDataCenterEntityId with IP address vmwNsxTDataCenterApplianceAddress and the publish_fqdns flag was set. Acti…
1.3.6.1.4.1.6876.120.1.0.35.0.24NotificationvmwNsxTCommunicationManagerFQDNReverseLookupFailureClearcurrentReverse DNS lookup succeeded for Manager node vmwNsxTDataCenterEntityId with IP address vmwNsxTDataCenterApplianceAddress or the publish_fqdns flag was cleared…
1.3.6.1.4.1.6876.120.1.0.35.0.25NotificationvmwNsxTCommunicationManagementChannelToManagerNodeDownLongcurrentManagement channel to Manager Node vmwNsxTDataCenterManagerNodeId (vmwNsxTDataCenterApplianceAddress) is down for 15 minutes. Action required: Ensure there is …
1.3.6.1.4.1.6876.120.1.0.35.0.26NotificationvmwNsxTCommunicationManagementChannelToManagerNodeDownLongClearcurrentManagement channel to Manager Node vmwNsxTDataCenterManagerNodeId (vmwNsxTDataCenterApplianceAddress) is up. Action required: None, receipt of this notificatio…
1.3.6.1.4.1.6876.120.1.0.35.0.29NotificationvmwNsxTCommunicationNetworkLatencyHighcurrentThe average network latency between manager nodes and host vmwNsxTDataCenterTransportNodeName (vmwNsxTDataCenterTransportNodeAddress) is more than 150 ms for 5…
1.3.6.1.4.1.6876.120.1.0.35.0.30NotificationvmwNsxTCommunicationNetworkLatencyHighClearcurrentThe average network latency between manager nodes and host vmwNsxTDataCenterTransportNodeName (vmwNsxTDataCenterTransportNodeAddress) is normal. Action require…
1.3.6.1.4.1.6876.120.1.0.35.0.31NotificationvmwNsxTCommunicationLimitedReachabilityOnDPUcurrentThe vmwNsxTDataCenterVerticalName collector vmwNsxTDataCenterCollectorIP can not be reached via vmknic(s)(stack vmwNsxTDataCenterStackAlias) on DVS vmwNsxTData…
1.3.6.1.4.1.6876.120.1.0.35.0.32NotificationvmwNsxTCommunicationLimitedReachabilityOnDPUClearcurrentThe vmwNsxTDataCenterVerticalName collector vmwNsxTDataCenterCollectorIP can be reached via vmknic(s) (stack vmwNsxTDataCenterStackAlias) on DVS vmwNsxTDataCen…
1.3.6.1.4.1.6876.120.1.0.35.0.33NotificationvmwNsxTCommunicationUnreachableCollectorOnDPUcurrentThe vmwNsxTDataCenterVerticalName collector vmwNsxTDataCenterCollectorIP can not be reached via existing vmknic(s)(stack vmwNsxTDataCenterStackAlias) on any DV…
1.3.6.1.4.1.6876.120.1.0.35.0.34NotificationvmwNsxTCommunicationUnreachableCollectorOnDPUClearcurrentThe vmwNsxTDataCenterVerticalName collector vmwNsxTDataCenterCollectorIP can be reached with existing vmknic(s)(stack vmwNsxTDataCenterStackAlias) now on DPU v…
1.3.6.1.4.1.6876.120.1.0.36IdentityvmwNsxTIdentityFirewallFeaturePrefixcurrentNotifications applicable to the IdentityFirewall feature have this OID prefix.
1.3.6.1.4.1.6876.120.1.0.36.0IdentityvmwNsxTIdentityFirewallFeaturecurrentSub-identifier added to ensure the next-to-last sub-identifier is zero for IdentityFirewall feature notifications.
1.3.6.1.4.1.6876.120.1.0.36.0.1NotificationvmwNsxTIdentityFirewallConnectivityToLDAPServerLostcurrentThe connectivity to LDAP server vmwNsxTDataCenterLDAPServer is lost. Action required: Check 1. The LDAP server is reachable from NSX nodes. 2. The LDAP server …
1.3.6.1.4.1.6876.120.1.0.36.0.2NotificationvmwNsxTIdentityFirewallConnectivityToLDAPServerLostClearcurrentThe connectivity to LDAP server vmwNsxTDataCenterLDAPServer is restored. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.36.0.3NotificationvmwNsxTIdentityFirewallErrorInDeltaSynccurrentErrors occurred while performing delta sync with vmwNsxTDataCenterDirectoryDomain. Action required: 1. Check if there are any connectivity to LDAP server lost …
1.3.6.1.4.1.6876.120.1.0.36.0.4NotificationvmwNsxTIdentityFirewallErrorInDeltaSyncClearcurrentNo errors occurred while performing delta sync with vmwNsxTDataCenterDirectoryDomain. Action required: None, receipt of this notification indicates event clear…
1.3.6.1.4.1.6876.120.1.0.38IdentityvmwNsxTIPAMFeaturePrefixcurrentNotifications applicable to the IPAM feature have this OID prefix.
1.3.6.1.4.1.6876.120.1.0.38.0IdentityvmwNsxTIPAMFeaturecurrentSub-identifier added to ensure the next-to-last sub-identifier is zero for IPAM feature notifications.
1.3.6.1.4.1.6876.120.1.0.38.0.1NotificationvmwNsxTIPAMIPBlockUsageVeryHighcurrentIP block usage of vmwNsxTDataCenterIntentPath is very high. IP block nearing its total capacity, creation of subnet using IP block might fail. Action required:…
1.3.6.1.4.1.6876.120.1.0.38.0.2NotificationvmwNsxTIPAMIPBlockUsageVeryHighClearcurrentIP block usage of vmwNsxTDataCenterIntentPath is below threshold level. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.38.0.3NotificationvmwNsxTIPAMIPPoolUsageVeryHighcurrentIP pool usage of vmwNsxTDataCenterIntentPath is very high. Creation of entity/service depends on IP being allocated from IP pool might fail. Action required: R…
1.3.6.1.4.1.6876.120.1.0.38.0.4NotificationvmwNsxTIPAMIPPoolUsageVeryHighClearcurrentIP pool usage of vmwNsxTDataCenterIntentPath is normal now. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.39IdentityvmwNsxTGatewayFirewallFeaturePrefixcurrentNotifications applicable to the GatewayFirewall feature have this OID prefix.
1.3.6.1.4.1.6876.120.1.0.39.0IdentityvmwNsxTGatewayFirewallFeaturecurrentSub-identifier added to ensure the next-to-last sub-identifier is zero for GatewayFirewall feature notifications.
1.3.6.1.4.1.6876.120.1.0.39.0.21NotificationvmwNsxTGatewayFirewallICMPFlowCountExceededcurrentGateway firewall flow table usage for ICMP traffic on logical router vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterFirewallICMPFlowUsage% which is at …
1.3.6.1.4.1.6876.120.1.0.39.0.22NotificationvmwNsxTGatewayFirewallICMPFlowCountExceededClearcurrentGateway firewall flow table usage on logical router vmwNsxTDataCenterEntityId has reached below the high threshold value of vmwNsxTDataCenterSystemUsageThresho…
1.3.6.1.4.1.6876.120.1.0.39.0.23NotificationvmwNsxTGatewayFirewallICMPFlowCountHighcurrentGateway firewall flow table usage for ICMP on logical router vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterFirewallICMPFlowUsage% which is at or above…
1.3.6.1.4.1.6876.120.1.0.39.0.24NotificationvmwNsxTGatewayFirewallICMPFlowCountHighClearcurrentGateway firewall flow table usage for ICMP on logical router vmwNsxTDataCenterEntityId has reached below the high threshold value of vmwNsxTDataCenterSystemUsa…
1.3.6.1.4.1.6876.120.1.0.39.0.25NotificationvmwNsxTGatewayFirewallIPFlowCountExceededcurrentGateway firewall flow table usage for IP traffic on logical router vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterFirewallIPFlowUsage% which is at or a…
1.3.6.1.4.1.6876.120.1.0.39.0.26NotificationvmwNsxTGatewayFirewallIPFlowCountExceededClearcurrentGateway firewall flow table usage on logical router vmwNsxTDataCenterEntityId has reached below the high threshold value of vmwNsxTDataCenterSystemUsageThresho…
1.3.6.1.4.1.6876.120.1.0.39.0.27NotificationvmwNsxTGatewayFirewallIPFlowCountHighcurrentGateway firewall flow table usage for IP on logical router vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterFirewallIPFlowUsage% which is at or above the…
1.3.6.1.4.1.6876.120.1.0.39.0.28NotificationvmwNsxTGatewayFirewallIPFlowCountHighClearcurrentGateway firewall flow table usage for non IP flows on logical router vmwNsxTDataCenterEntityId has reached below the high threshold value of vmwNsxTDataCenterS…
1.3.6.1.4.1.6876.120.1.0.39.0.29NotificationvmwNsxTGatewayFirewallTcpHalfOpenFlowCountExceededcurrentGateway firewall flow table usage for TCP half-open traffic on logical router vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterFirewallHalfopenFlowUsage%…
1.3.6.1.4.1.6876.120.1.0.39.0.30NotificationvmwNsxTGatewayFirewallTcpHalfOpenFlowCountExceededClearcurrentGateway firewall flow table usage on logical router vmwNsxTDataCenterEntityId has reached below the high threshold value of vmwNsxTDataCenterSystemUsageThresho…
1.3.6.1.4.1.6876.120.1.0.39.0.31NotificationvmwNsxTGatewayFirewallTcpHalfOpenFlowCountHighcurrentGateway firewall flow table usage for TCP on logical router vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterFirewallHalfopenFlowUsage% which is at or ab…
1.3.6.1.4.1.6876.120.1.0.39.0.32NotificationvmwNsxTGatewayFirewallTcpHalfOpenFlowCountHighClearcurrentGateway firewall flow table usage for TCP half-open on logical router vmwNsxTDataCenterEntityId has reached below the high threshold value of vmwNsxTDataCenter…
1.3.6.1.4.1.6876.120.1.0.39.0.33NotificationvmwNsxTGatewayFirewallUDPFlowCountExceededcurrentGateway firewall flow table usage for UDP traffic on logical router vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterFirewallUDPFlowUsage% which is at or…
1.3.6.1.4.1.6876.120.1.0.39.0.34NotificationvmwNsxTGatewayFirewallUDPFlowCountExceededClearcurrentGateway firewall flow table usage on logical router vmwNsxTDataCenterEntityId has reached below the high threshold. Action required: None, receipt of this noti…
1.3.6.1.4.1.6876.120.1.0.39.0.35NotificationvmwNsxTGatewayFirewallUDPFlowCountHighcurrentGateway firewall flow table usage for UDP on logical router vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterFirewallUDPFlowUsage% which is at or above t…
1.3.6.1.4.1.6876.120.1.0.39.0.36NotificationvmwNsxTGatewayFirewallUDPFlowCountHighClearcurrentGateway firewall flow table usage for UDP on logical router vmwNsxTDataCenterEntityId has reached below the high threshold. Action required: None, receipt of t…
1.3.6.1.4.1.6876.120.1.0.40IdentityvmwNsxTClusteringFeaturePrefixcurrentNotifications applicable to the Clustering feature have this OID prefix.
1.3.6.1.4.1.6876.120.1.0.40.0IdentityvmwNsxTClusteringFeaturecurrentSub-identifier added to ensure the next-to-last sub-identifier is zero for Clustering feature notifications.
1.3.6.1.4.1.6876.120.1.0.40.0.1NotificationvmwNsxTClusteringClusterDegradedcurrentGroup member vmwNsxTDataCenterManagerNodeId of service vmwNsxTDataCenterGroupType is down. Action required: 1. Invoke the NSX CLI command 'get cluster status' …
1.3.6.1.4.1.6876.120.1.0.40.0.2NotificationvmwNsxTClusteringClusterDegradedClearcurrentGroup member vmwNsxTDataCenterManagerNodeId of vmwNsxTDataCenterGroupType is up. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.40.0.3NotificationvmwNsxTClusteringClusterUnavailablecurrentAll group members vmwNsxTDataCenterManagerNodeIDS of service vmwNsxTDataCenterGroupType are down. Action required: 1. Ensure the service for vmwNsxTDataCenterG…
1.3.6.1.4.1.6876.120.1.0.40.0.4NotificationvmwNsxTClusteringClusterUnavailableClearcurrentAll group members vmwNsxTDataCenterManagerNodeIDS of service vmwNsxTDataCenterGroupType are up. Action required: None, receipt of this notification indicates e…
1.3.6.1.4.1.6876.120.1.0.41IdentityvmwNsxTNSXApplicationPlatformCommunicationFeaturePrefixcurrentNotifications applicable to the NSXApplicationPlatformCommunication feature have this OID prefix.
1.3.6.1.4.1.6876.120.1.0.41.0IdentityvmwNsxTNSXApplicationPlatformCommunicationFeaturecurrentSub-identifier added to ensure the next-to-last sub-identifier is zero for NSXApplicationPlatformCommunication feature notifications.
1.3.6.1.4.1.6876.120.1.0.41.0.1NotificationvmwNsxTNSXApplicationPlatformCommunicationMgrDisconnectedcurrentThe NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is disconnected from the NSX management cluster. Action required: Check whether the manager…
1.3.6.1.4.1.6876.120.1.0.41.0.2NotificationvmwNsxTNSXApplicationPlatformCommunicationMgrDisconnectedClearcurrentThe NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is reconnected to the NSX management cluster. Action required: None, receipt of this notifi…
1.3.6.1.4.1.6876.120.1.0.41.0.7NotificationvmwNsxTNSXApplicationPlatformCommunicationDelayInOverflowcurrentThe number of pending messages in the messaging topic Over Flow is above the pending message threshold of vmwNsxTDataCenterNappMessagingLAGThreshold. Action re…
1.3.6.1.4.1.6876.120.1.0.41.0.8NotificationvmwNsxTNSXApplicationPlatformCommunicationDelayInOverflowClearcurrentThe number of pending messages in the messaging topic Over Flow is below the pending message threshold of vmwNsxTDataCenterNappMessagingLAGThreshold. Action re…
1.3.6.1.4.1.6876.120.1.0.41.0.11NotificationvmwNsxTNSXApplicationPlatformCommunicationDelayInRawflowcurrentThe number of pending messages in the messaging topic Raw Flow is above the pending message threshold of vmwNsxTDataCenterNappMessagingLAGThreshold. Action req…
1.3.6.1.4.1.6876.120.1.0.41.0.12NotificationvmwNsxTNSXApplicationPlatformCommunicationDelayInRawflowClearcurrentThe number of pending messages in the messaging topic Raw Flow is below the pending message threshold of vmwNsxTDataCenterNappMessagingLAGThreshold. Action req…
1.3.6.1.4.1.6876.120.1.0.41.0.13NotificationvmwNsxTNSXApplicationPlatformCommunicationExpDisconnectedcurrentThe flow exporter on Transport node vmwNsxTDataCenterEntityId is disconnected from the NSX Application Platform cluster's messaging broker. Data collection is …
1.3.6.1.4.1.6876.120.1.0.41.0.14NotificationvmwNsxTNSXApplicationPlatformCommunicationExpDisconnectedClearcurrentThe flow exporter on Transport node vmwNsxTDataCenterEntityId has reconnected to the NSX Application Platform cluster's messaging broker. Action required: None…
1.3.6.1.4.1.6876.120.1.0.41.0.17NotificationvmwNsxTNSXApplicationPlatformCommunicationExpDisconnectDPUcurrentThe flow exporter on Transport node vmwNsxTDataCenterEntityId DPU vmwNsxTDataCenterDPUId is disconnected from the Intelligence node's messaging broker. Data co…
1.3.6.1.4.1.6876.120.1.0.41.0.18NotificationvmwNsxTNSXApplicationPlatformCommunicationExpDisconnectDPUClearcurrentThe flow exporter on Transport node vmwNsxTDataCenterEntityId DPU vmwNsxTDataCenterDPUId has reconnected to the Intelligence node's messaging broker. Action re…
1.3.6.1.4.1.6876.120.1.0.42IdentityvmwNsxTMTUCheckFeaturePrefixcurrentNotifications applicable to the MTUCheck feature have this OID prefix.
1.3.6.1.4.1.6876.120.1.0.42.0IdentityvmwNsxTMTUCheckFeaturecurrentSub-identifier added to ensure the next-to-last sub-identifier is zero for MTUCheck feature notifications.
1.3.6.1.4.1.6876.120.1.0.42.0.1NotificationvmwNsxTMTUCheckMTUMismatchWithinTransportZonecurrentMTU configuration mismatch between Transport Nodes (ESXi, KVM and Edge) attached to the same Transport Zone. MTU values on all switches attached to the same Tr…
1.3.6.1.4.1.6876.120.1.0.42.0.2NotificationvmwNsxTMTUCheckMTUMismatchWithinTransportZoneClearcurrentAll MTU values between Transport Nodes attached to the same Transport Zone are consistent now. Action required: None, receipt of this notification indicates ev…
1.3.6.1.4.1.6876.120.1.0.42.0.3NotificationvmwNsxTMTUCheckGlobalRouterMTUTooBigcurrentThe global router MTU configuration is bigger than MTU of switches in overlay Transport Zone which connects to Tier0 or Tier1. Global router MTU value should b…
1.3.6.1.4.1.6876.120.1.0.42.0.4NotificationvmwNsxTMTUCheckGlobalRouterMTUTooBigClearcurrentThe global router MTU is less than the MTU of overlay Transport Zone now. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.43IdentityvmwNsxTNSXApplicationPlatformHealthFeaturePrefixcurrentNotifications applicable to the NSXApplicationPlatformHealth feature have this OID prefix.
1.3.6.1.4.1.6876.120.1.0.43.0IdentityvmwNsxTNSXApplicationPlatformHealthFeaturecurrentSub-identifier added to ensure the next-to-last sub-identifier is zero for NSXApplicationPlatformHealth feature notifications.
1.3.6.1.4.1.6876.120.1.0.43.0.1NotificationvmwNsxTNSXApplicationPlatformHealthAnalyticsCPUUsageHighcurrentThe CPU usage of Analytics service is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out all services or the …
1.3.6.1.4.1.6876.120.1.0.43.0.2NotificationvmwNsxTNSXApplicationPlatformHealthAnalyticsCPUUsageHighClearcurrentThe CPU usage of Analytics service is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notifica…
1.3.6.1.4.1.6876.120.1.0.43.0.3NotificationvmwNsxTNSXApplicationPlatformHealthAnalyticsCPUUsageVeryHicurrentThe CPU usage of Analytics service is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out all services or…
1.3.6.1.4.1.6876.120.1.0.43.0.4NotificationvmwNsxTNSXApplicationPlatformHealthAnalyticsCPUUsageVeryHiClearcurrentThe CPU usage of Analytics service is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this not…
1.3.6.1.4.1.6876.120.1.0.43.0.5NotificationvmwNsxTNSXApplicationPlatformHealthAnalyticsDiskUsageHighcurrentThe disk usage of Analytics service is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Clean up files not needed. Sc…
1.3.6.1.4.1.6876.120.1.0.43.0.6NotificationvmwNsxTNSXApplicationPlatformHealthAnalyticsDiskUsageHighClearcurrentThe disk usage of Analytics service is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notific…
1.3.6.1.4.1.6876.120.1.0.43.0.7NotificationvmwNsxTNSXApplicationPlatformHealthAnalyticsDiskUsageVeryHicurrentThe disk usage of Analytics service is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Clean up files not neede…
1.3.6.1.4.1.6876.120.1.0.43.0.8NotificationvmwNsxTNSXApplicationPlatformHealthAnalyticsDiskUsageVeryHiClearcurrentThe disk usage of Analytics service is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this no…
1.3.6.1.4.1.6876.120.1.0.43.0.9NotificationvmwNsxTNSXApplicationPlatformHealthAnalyticsMemoryUsageHighcurrentThe memory usage of Analytics service is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out all services or t…
1.3.6.1.4.1.6876.120.1.0.43.0.10NotificationvmwNsxTNSXApplicationPlatformHealthAnalyticsMemoryUsageHighClearcurrentThe memory usage of Analytics service is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notif…
1.3.6.1.4.1.6876.120.1.0.43.0.11NotificationvmwNsxTNSXApplicationPlatformHealthAnalyticsMemUsageVeryHicurrentThe memory usage of Analytics service is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out all services…
1.3.6.1.4.1.6876.120.1.0.43.0.12NotificationvmwNsxTNSXApplicationPlatformHealthAnalyticsMemUsageVeryHiClearcurrentThe memory usage of Analytics service is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this …
1.3.6.1.4.1.6876.120.1.0.43.0.13NotificationvmwNsxTNSXApplicationPlatformHealthClusterCPUUsageHighcurrentThe CPU usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. A…
1.3.6.1.4.1.6876.120.1.0.43.0.14NotificationvmwNsxTNSXApplicationPlatformHealthClusterCPUUsageHighClearcurrentThe CPU usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. A…
1.3.6.1.4.1.6876.120.1.0.43.0.15NotificationvmwNsxTNSXApplicationPlatformHealthClusterCPUUsageVeryHighcurrentThe CPU usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshol…
1.3.6.1.4.1.6876.120.1.0.43.0.16NotificationvmwNsxTNSXApplicationPlatformHealthClusterCPUUsageVeryHighClearcurrentThe CPU usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshol…
1.3.6.1.4.1.6876.120.1.0.43.0.17NotificationvmwNsxTNSXApplicationPlatformHealthClusterDiskUsageHighcurrentThe disk usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. …
1.3.6.1.4.1.6876.120.1.0.43.0.18NotificationvmwNsxTNSXApplicationPlatformHealthClusterDiskUsageHighClearcurrentThe disk usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. …
1.3.6.1.4.1.6876.120.1.0.43.0.19NotificationvmwNsxTNSXApplicationPlatformHealthClusterDiskUsageVeryHighcurrentThe disk usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is above the very high threshold value of vmwNsxTDataCenterSystemUsageThresho…
1.3.6.1.4.1.6876.120.1.0.43.0.20NotificationvmwNsxTNSXApplicationPlatformHealthClusterDiskUsageVeryHighClearcurrentThe disk usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is below the very high threshold value of vmwNsxTDataCenterSystemUsageThresho…
1.3.6.1.4.1.6876.120.1.0.43.0.21NotificationvmwNsxTNSXApplicationPlatformHealthClusterMemoryUsageHighcurrentThe memory usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%…
1.3.6.1.4.1.6876.120.1.0.43.0.22NotificationvmwNsxTNSXApplicationPlatformHealthClusterMemoryUsageHighClearcurrentThe memory usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%…
1.3.6.1.4.1.6876.120.1.0.43.0.23NotificationvmwNsxTNSXApplicationPlatformHealthClusterMemUsageVeryHicurrentThe memory usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is above the very high threshold value of vmwNsxTDataCenterSystemUsageThres…
1.3.6.1.4.1.6876.120.1.0.43.0.24NotificationvmwNsxTNSXApplicationPlatformHealthClusterMemUsageVeryHiClearcurrentThe memory usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is below the very high threshold value of vmwNsxTDataCenterSystemUsageThres…
1.3.6.1.4.1.6876.120.1.0.43.0.31NotificationvmwNsxTNSXApplicationPlatformHealthConfigDbCPUUsageHicurrentThe CPU usage of Configuration Database service is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out all ser…
1.3.6.1.4.1.6876.120.1.0.43.0.32NotificationvmwNsxTNSXApplicationPlatformHealthConfigDbCPUUsageHiClearcurrentThe CPU usage of Configuration Database service is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of …
1.3.6.1.4.1.6876.120.1.0.43.0.33NotificationvmwNsxTNSXApplicationPlatformHealthConfigDbCPUUsageVeryHicurrentThe CPU usage of Configuration Database service is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out al…
1.3.6.1.4.1.6876.120.1.0.43.0.34NotificationvmwNsxTNSXApplicationPlatformHealthConfigDbCPUUsageVeryHiClearcurrentThe CPU usage of Configuration Database service is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receip…
1.3.6.1.4.1.6876.120.1.0.43.0.35NotificationvmwNsxTNSXApplicationPlatformHealthConfigDbDiskUsageHighcurrentThe disk usage of Configuration Database service is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Clean up files n…
1.3.6.1.4.1.6876.120.1.0.43.0.36NotificationvmwNsxTNSXApplicationPlatformHealthConfigDbDiskUsageHighClearcurrentThe disk usage of Configuration Database service is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of…
1.3.6.1.4.1.6876.120.1.0.43.0.37NotificationvmwNsxTNSXApplicationPlatformHealthConfigDbDiskUsageVeryHicurrentThe disk usage of Configuration Database service is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Clean up fi…
1.3.6.1.4.1.6876.120.1.0.43.0.38NotificationvmwNsxTNSXApplicationPlatformHealthConfigDbDiskUsageVeryHiClearcurrentThe disk usage of Configuration Database service is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, recei…
1.3.6.1.4.1.6876.120.1.0.43.0.39NotificationvmwNsxTNSXApplicationPlatformHealthConfigDbMemUsageVeryHighcurrentThe memory usage of Configuration Database service is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out…
1.3.6.1.4.1.6876.120.1.0.43.0.40NotificationvmwNsxTNSXApplicationPlatformHealthConfigDbMemUsageVeryHighClearcurrentThe memory usage of Configuration Database service is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, rec…
1.3.6.1.4.1.6876.120.1.0.43.0.41NotificationvmwNsxTNSXApplicationPlatformHealthDatastoreCPUUsageHighcurrentThe CPU usage of Data Storage service is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out all services or t…
1.3.6.1.4.1.6876.120.1.0.43.0.42NotificationvmwNsxTNSXApplicationPlatformHealthDatastoreCPUUsageHighClearcurrentThe CPU usage of Data Storage service is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notif…
1.3.6.1.4.1.6876.120.1.0.43.0.43NotificationvmwNsxTNSXApplicationPlatformHealthDatastoreCPUUsageVeryHicurrentThe CPU usage of Data Storage service is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out all services…
1.3.6.1.4.1.6876.120.1.0.43.0.44NotificationvmwNsxTNSXApplicationPlatformHealthDatastoreCPUUsageVeryHiClearcurrentThe CPU usage of Data Storage service is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this …
1.3.6.1.4.1.6876.120.1.0.43.0.45NotificationvmwNsxTNSXApplicationPlatformHealthDatastoreDiskUsageHighcurrentThe disk usage of Data Storage service is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out or scale up the …
1.3.6.1.4.1.6876.120.1.0.43.0.46NotificationvmwNsxTNSXApplicationPlatformHealthDatastoreDiskUsageHighClearcurrentThe disk usage of Data Storage service is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this noti…
1.3.6.1.4.1.6876.120.1.0.43.0.47NotificationvmwNsxTNSXApplicationPlatformHealthDatastoreDiskUsageVeryHicurrentThe disk usage of Data Storage service is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out or scale up…
1.3.6.1.4.1.6876.120.1.0.43.0.48NotificationvmwNsxTNSXApplicationPlatformHealthDatastoreDiskUsageVeryHiClearcurrentThe disk usage of Data Storage service is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this…
1.3.6.1.4.1.6876.120.1.0.43.0.49NotificationvmwNsxTNSXApplicationPlatformHealthDatastoreMemoryUsageHighcurrentThe memory usage of Data Storage service is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out all services o…
1.3.6.1.4.1.6876.120.1.0.43.0.50NotificationvmwNsxTNSXApplicationPlatformHealthDatastoreMemoryUsageHighClearcurrentThe memory usage of Data Storage service is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this no…
1.3.6.1.4.1.6876.120.1.0.43.0.51NotificationvmwNsxTNSXApplicationPlatformHealthDatastoreMemUsageVeryHicurrentThe memory usage of Data Storage service is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out all servi…
1.3.6.1.4.1.6876.120.1.0.43.0.52NotificationvmwNsxTNSXApplicationPlatformHealthDatastoreMemUsageVeryHiClearcurrentThe memory usage of Data Storage service is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of th…
1.3.6.1.4.1.6876.120.1.0.43.0.53NotificationvmwNsxTNSXApplicationPlatformHealthMessagingCPUUsageHighcurrentThe CPU usage of Messaging service is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out all services or the …
1.3.6.1.4.1.6876.120.1.0.43.0.54NotificationvmwNsxTNSXApplicationPlatformHealthMessagingCPUUsageHighClearcurrentThe CPU usage of Messaging service is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notifica…
1.3.6.1.4.1.6876.120.1.0.43.0.55NotificationvmwNsxTNSXApplicationPlatformHealthMessagingCPUUsageVeryHicurrentThe CPU usage of Messaging service is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out all services or…
1.3.6.1.4.1.6876.120.1.0.43.0.56NotificationvmwNsxTNSXApplicationPlatformHealthMessagingCPUUsageVeryHiClearcurrentThe CPU usage of Messaging service is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this not…
1.3.6.1.4.1.6876.120.1.0.43.0.57NotificationvmwNsxTNSXApplicationPlatformHealthMessagingDiskUsageHighcurrentThe disk usage of Messaging service is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Clean up files not needed. Sc…
1.3.6.1.4.1.6876.120.1.0.43.0.58NotificationvmwNsxTNSXApplicationPlatformHealthMessagingDiskUsageHighClearcurrentThe disk usage of Messaging service is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notific…
1.3.6.1.4.1.6876.120.1.0.43.0.59NotificationvmwNsxTNSXApplicationPlatformHealthMessagingDiskUsageVeryHicurrentThe disk usage of Messaging service is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Clean up files not neede…
1.3.6.1.4.1.6876.120.1.0.43.0.60NotificationvmwNsxTNSXApplicationPlatformHealthMessagingDiskUsageVeryHiClearcurrentThe disk usage of Messaging service is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this no…
1.3.6.1.4.1.6876.120.1.0.43.0.61NotificationvmwNsxTNSXApplicationPlatformHealthMessagingMemoryUsageHighcurrentThe memory usage of Messaging service is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out all services or t…
1.3.6.1.4.1.6876.120.1.0.43.0.62NotificationvmwNsxTNSXApplicationPlatformHealthMessagingMemoryUsageHighClearcurrentThe memory usage of Messaging service is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notif…
1.3.6.1.4.1.6876.120.1.0.43.0.63NotificationvmwNsxTNSXApplicationPlatformHealthMessagingMemUsageVeryHicurrentThe memory usage of Messaging service is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out all services…
1.3.6.1.4.1.6876.120.1.0.43.0.64NotificationvmwNsxTNSXApplicationPlatformHealthMessagingMemUsageVeryHiClearcurrentThe memory usage of Messaging service is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this …
1.3.6.1.4.1.6876.120.1.0.43.0.65NotificationvmwNsxTNSXApplicationPlatformHealthNodeCPUUsageHighcurrentThe CPU usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Actio…
1.3.6.1.4.1.6876.120.1.0.43.0.66NotificationvmwNsxTNSXApplicationPlatformHealthNodeCPUUsageHighClearcurrentThe CPU usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Actio…
1.3.6.1.4.1.6876.120.1.0.43.0.67NotificationvmwNsxTNSXApplicationPlatformHealthNodeCPUUsageVeryHighcurrentThe CPU usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. …
1.3.6.1.4.1.6876.120.1.0.43.0.68NotificationvmwNsxTNSXApplicationPlatformHealthNodeCPUUsageVeryHighClearcurrentThe CPU usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. …
1.3.6.1.4.1.6876.120.1.0.43.0.69NotificationvmwNsxTNSXApplicationPlatformHealthNodeDiskUsageHighcurrentThe disk usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Acti…
1.3.6.1.4.1.6876.120.1.0.43.0.70NotificationvmwNsxTNSXApplicationPlatformHealthNodeDiskUsageHighClearcurrentThe disk usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Acti…
1.3.6.1.4.1.6876.120.1.0.43.0.71NotificationvmwNsxTNSXApplicationPlatformHealthNodeDiskUsageVeryHighcurrentThe disk usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.…
1.3.6.1.4.1.6876.120.1.0.43.0.72NotificationvmwNsxTNSXApplicationPlatformHealthNodeDiskUsageVeryHighClearcurrentThe disk usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.…
1.3.6.1.4.1.6876.120.1.0.43.0.73NotificationvmwNsxTNSXApplicationPlatformHealthNodeMemoryUsageHighcurrentThe memory usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Ac…
1.3.6.1.4.1.6876.120.1.0.43.0.74NotificationvmwNsxTNSXApplicationPlatformHealthNodeMemoryUsageHighClearcurrentThe memory usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Ac…
1.3.6.1.4.1.6876.120.1.0.43.0.75NotificationvmwNsxTNSXApplicationPlatformHealthNodeMemoryUsageVeryHighcurrentThe memory usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold…
1.3.6.1.4.1.6876.120.1.0.43.0.76NotificationvmwNsxTNSXApplicationPlatformHealthNodeMemoryUsageVeryHighClearcurrentThe memory usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold…
1.3.6.1.4.1.6876.120.1.0.43.0.77NotificationvmwNsxTNSXApplicationPlatformHealthNodeStatusDegradedcurrentNSX Application Platform node vmwNsxTDataCenterNappNodeName is degraded. Action required: In the NSX UI, navigate to System | NSX Application Platform | Resour…
1.3.6.1.4.1.6876.120.1.0.43.0.78NotificationvmwNsxTNSXApplicationPlatformHealthNodeStatusDegradedClearcurrentNSX Application Platform node vmwNsxTDataCenterNappNodeName is running properly. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.43.0.79NotificationvmwNsxTNSXApplicationPlatformHealthNodeStatusDowncurrentNSX Application Platform node vmwNsxTDataCenterNappNodeName is not running. Action required: In the NSX UI, navigate to System | NSX Application Platform | Res…
1.3.6.1.4.1.6876.120.1.0.43.0.80NotificationvmwNsxTNSXApplicationPlatformHealthNodeStatusDownClearcurrentNSX Application Platform node vmwNsxTDataCenterNappNodeName is running properly. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.43.0.81NotificationvmwNsxTNSXApplicationPlatformHealthPlatformCPUUsageHighcurrentThe CPU usage of Platform Services service is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out all services.
1.3.6.1.4.1.6876.120.1.0.43.0.82NotificationvmwNsxTNSXApplicationPlatformHealthPlatformCPUUsageHighClearcurrentThe CPU usage of Platform Services service is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this …
1.3.6.1.4.1.6876.120.1.0.43.0.83NotificationvmwNsxTNSXApplicationPlatformHealthPlatformCPUUsageVeryHighcurrentThe CPU usage of Platform Services service is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out all ser…
1.3.6.1.4.1.6876.120.1.0.43.0.84NotificationvmwNsxTNSXApplicationPlatformHealthPlatformCPUUsageVeryHighClearcurrentThe CPU usage of Platform Services service is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of …
1.3.6.1.4.1.6876.120.1.0.43.0.85NotificationvmwNsxTNSXApplicationPlatformHealthPlatformDiskUsageHighcurrentThe disk usage of Platform Services service is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Clean up files not ne…
1.3.6.1.4.1.6876.120.1.0.43.0.86NotificationvmwNsxTNSXApplicationPlatformHealthPlatformDiskUsageHighClearcurrentThe disk usage of Platform Services service is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this…
1.3.6.1.4.1.6876.120.1.0.43.0.87NotificationvmwNsxTNSXApplicationPlatformHealthPlatformDiskUsageVeryHicurrentThe disk usage of Platform Services service is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Clean up files n…
1.3.6.1.4.1.6876.120.1.0.43.0.88NotificationvmwNsxTNSXApplicationPlatformHealthPlatformDiskUsageVeryHiClearcurrentThe disk usage of Platform Services service is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of…
1.3.6.1.4.1.6876.120.1.0.43.0.89NotificationvmwNsxTNSXApplicationPlatformHealthPlatformMemoryUsageHighcurrentThe memory usage of Platform Services service is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out all servi…
1.3.6.1.4.1.6876.120.1.0.43.0.90NotificationvmwNsxTNSXApplicationPlatformHealthPlatformMemoryUsageHighClearcurrentThe memory usage of Platform Services service is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of th…
1.3.6.1.4.1.6876.120.1.0.43.0.91NotificationvmwNsxTNSXApplicationPlatformHealthPlatformMemUsageVeryHicurrentThe memory usage of Platform Services service is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out all …
1.3.6.1.4.1.6876.120.1.0.43.0.92NotificationvmwNsxTNSXApplicationPlatformHealthPlatformMemUsageVeryHiClearcurrentThe memory usage of Platform Services service is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt …
1.3.6.1.4.1.6876.120.1.0.43.0.93NotificationvmwNsxTNSXApplicationPlatformHealthServiceStatusDegradedcurrentService vmwNsxTDataCenterNappServiceName is degraded. The service may still be able to reach a quorum while pods associated with vmwNsxTDataCenterNappServiceNa…
1.3.6.1.4.1.6876.120.1.0.43.0.94NotificationvmwNsxTNSXApplicationPlatformHealthServiceStatusDegradedClearcurrentService vmwNsxTDataCenterNappServiceName is running properly. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.43.0.95NotificationvmwNsxTNSXApplicationPlatformHealthServiceStatusDowncurrentService vmwNsxTDataCenterNappServiceName is not running. Action required: In the NSX UI, navigate to System | NSX Application Platform | Core Services to check…
1.3.6.1.4.1.6876.120.1.0.43.0.96NotificationvmwNsxTNSXApplicationPlatformHealthServiceStatusDownClearcurrentService vmwNsxTDataCenterNappServiceName is running properly. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.43.0.97NotificationvmwNsxTNSXApplicationPlatformHealthMetricsCPUUsageHighcurrentThe CPU usage of Metrics service is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out all services.
1.3.6.1.4.1.6876.120.1.0.43.0.98NotificationvmwNsxTNSXApplicationPlatformHealthMetricsCPUUsageHighClearcurrentThe CPU usage of Metrics service is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notificati…
1.3.6.1.4.1.6876.120.1.0.43.0.99NotificationvmwNsxTNSXApplicationPlatformHealthMetricsCPUUsageVeryHighcurrentThe CPU usage of Metrics service is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out all services.
1.3.6.1.4.1.6876.120.1.0.43.0.100NotificationvmwNsxTNSXApplicationPlatformHealthMetricsCPUUsageVeryHighClearcurrentThe CPU usage of Metrics service is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notif…
1.3.6.1.4.1.6876.120.1.0.43.0.101NotificationvmwNsxTNSXApplicationPlatformHealthMetricsDiskUsageHicurrentThe disk usage of Metrics service is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Clean up files not needed. Scal…
1.3.6.1.4.1.6876.120.1.0.43.0.102NotificationvmwNsxTNSXApplicationPlatformHealthMetricsDiskUsageHiClearcurrentThe disk usage of Metrics service is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notificat…
1.3.6.1.4.1.6876.120.1.0.43.0.103NotificationvmwNsxTNSXApplicationPlatformHealthMetricsDiskUsageVeryHighcurrentThe disk usage of Metrics service is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Clean up files not needed.…
1.3.6.1.4.1.6876.120.1.0.43.0.104NotificationvmwNsxTNSXApplicationPlatformHealthMetricsDiskUsageVeryHighClearcurrentThe disk usage of Metrics service is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this noti…
1.3.6.1.4.1.6876.120.1.0.43.0.105NotificationvmwNsxTNSXApplicationPlatformHealthMetricsMemUasgeHicurrentThe memory usage of Metrics service is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out all services.
1.3.6.1.4.1.6876.120.1.0.43.0.106NotificationvmwNsxTNSXApplicationPlatformHealthMetricsMemUasgeHiClearcurrentThe memory usage of Metrics service is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this notific…
1.3.6.1.4.1.6876.120.1.0.43.0.107NotificationvmwNsxTNSXApplicationPlatformHealthMetricsMemUsageVeryHighcurrentThe memory usage of Metrics service is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out all services.
1.3.6.1.4.1.6876.120.1.0.43.0.108NotificationvmwNsxTNSXApplicationPlatformHealthMetricsMemUsageVeryHighClearcurrentThe memory usage of Metrics service is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt of this no…
1.3.6.1.4.1.6876.120.1.0.43.0.109NotificationvmwNsxTNSXApplicationPlatformHealthConfigDbMemUsageHighcurrentThe memory usage of Configuration Database service is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: Scale out all …
1.3.6.1.4.1.6876.120.1.0.43.0.110NotificationvmwNsxTNSXApplicationPlatformHealthConfigDbMemUsageHighClearcurrentThe memory usage of Configuration Database service is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. Action required: None, receipt …
1.3.6.1.4.1.6876.120.1.0.43.0.117NotificationvmwNsxTNSXApplicationPlatformHealthNappStatusDegradedcurrentNSX Application Platform cluster vmwNsxTDataCenterNappClusterId overall status is degraded. Action required: Get more information from alarms of nodes and serv…
1.3.6.1.4.1.6876.120.1.0.43.0.118NotificationvmwNsxTNSXApplicationPlatformHealthNappStatusDegradedClearcurrentNSX Application Platform cluster vmwNsxTDataCenterNappClusterId is running properly. Action required: None, receipt of this notification indicates event cleare…
1.3.6.1.4.1.6876.120.1.0.43.0.119NotificationvmwNsxTNSXApplicationPlatformHealthNappStatusDowncurrentNSX Application Platform cluster vmwNsxTDataCenterNappClusterId overall status is down. Action required: Get more information from alarms of nodes and services.
1.3.6.1.4.1.6876.120.1.0.43.0.120NotificationvmwNsxTNSXApplicationPlatformHealthNappStatusDownClearcurrentNSX Application Platform cluster vmwNsxTDataCenterNappClusterId is running properly. Action required: None, receipt of this notification indicates event cleare…
1.3.6.1.4.1.6876.120.1.0.45IdentityvmwNsxTEdgeFeaturePrefixcurrentNotifications applicable to the Edge feature have this OID prefix.
1.3.6.1.4.1.6876.120.1.0.45.0IdentityvmwNsxTEdgeFeaturecurrentSub-identifier added to ensure the next-to-last sub-identifier is zero for Edge feature notifications.
1.3.6.1.4.1.6876.120.1.0.45.0.1NotificationvmwNsxTEdgeEdgeNodeSettingsAndvSphereSettingsAreChangedcurrentThe Edge node vmwNsxTDataCenterEntityId settings and vSphere configuration are changed and does not match the policy intent configuration. The Edge node config…
1.3.6.1.4.1.6876.120.1.0.45.0.2NotificationvmwNsxTEdgeEdgeNodeSettingsAndvSphereSettingsAreChangedClearcurrentEdge node vmwNsxTDataCenterEntityId node settings and vSphere settings are consistent with policy intent now. Action required: None, receipt of this notificati…
1.3.6.1.4.1.6876.120.1.0.45.0.3NotificationvmwNsxTEdgeEdgeNodeSettingsMismatchcurrentThe Edge node vmwNsxTDataCenterEntityId settings configuration does not match the policy intent configuration. The Edge node configuration visible to user on U…
1.3.6.1.4.1.6876.120.1.0.45.0.4NotificationvmwNsxTEdgeEdgeNodeSettingsMismatchClearcurrentEdge node vmwNsxTDataCenterEntityId node settings are consistent with policy intent now. Action required: None, receipt of this notification indicates event cl…
1.3.6.1.4.1.6876.120.1.0.45.0.5NotificationvmwNsxTEdgeEdgeVmvSphereSettingsMismatchcurrentThe Edge node vmwNsxTDataCenterEntityId configuration on vSphere does not match the policy intent configuration. The Edge node configuration visible to user on…
1.3.6.1.4.1.6876.120.1.0.45.0.6NotificationvmwNsxTEdgeEdgeVmvSphereSettingsMismatchClearcurrentEdge node vmwNsxTDataCenterEntityId VM vSphere settings are consistent with policy intent now. Action required: None, receipt of this notification indicates ev…
1.3.6.1.4.1.6876.120.1.0.45.0.7NotificationvmwNsxTEdgeEdgevSphereLocationMismatchcurrentThe Edge node vmwNsxTDataCenterEntityId has been moved using vMotion. The Edge node vmwNsxTDataCenterEntityId, the configuration on vSphere does not match the …
1.3.6.1.4.1.6876.120.1.0.45.0.8NotificationvmwNsxTEdgeEdgevSphereLocationMismatchClearcurrentEdge node vmwNsxTDataCenterEntityId node vSphere settings are consistent with policy intent now. Action required: None, receipt of this notification indicates …
1.3.6.1.4.1.6876.120.1.0.45.0.9NotificationvmwNsxTEdgeEdgeVMPresentInNSXInventoryNotPresentInvCentercurrentThe VM vmwNsxTDataCenterPolicyEdgeVMName with moref id vmwNsxTDataCenterVMMorefId corresponding to the Edge Transport node vmwNsxTDataCenterEntityId vSphere pl…
1.3.6.1.4.1.6876.120.1.0.45.0.10NotificationvmwNsxTEdgeEdgeVMPresentInNSXInventoryNotPresentInvCenterClearcurrentEdge node vmwNsxTDataCenterEntityId with VM moref id vmwNsxTDataCenterVMMorefId is present in both NSX inventory and vCenter. Action required: None, receipt of…
1.3.6.1.4.1.6876.120.1.0.45.0.11NotificationvmwNsxTEdgeEdgeVMNotPresentInBothNSXInventoryAndvCentercurrentThe VM vmwNsxTDataCenterPolicyEdgeVMName with moref id vmwNsxTDataCenterVMMorefId corresponding to the Edge Transport node vmwNsxTDataCenterEntityId vSphere pl…
1.3.6.1.4.1.6876.120.1.0.45.0.12NotificationvmwNsxTEdgeEdgeVMNotPresentInBothNSXInventoryAndvCenterClearcurrentEdge node vmwNsxTDataCenterEntityId with VM moref id vmwNsxTDataCenterVMMorefId is present in both NSX inventory and vCenter. Action required: None, receipt of…
1.3.6.1.4.1.6876.120.1.0.45.0.13NotificationvmwNsxTEdgeFailedToDeleteTheOldVMInvCenterDuringRedeploycurrentFailed to power off and delete the Edge node vmwNsxTDataCenterEntityId VM with moref id vmwNsxTDataCenterVMMorefId in vCenter during Redeploy operation. A new …
1.3.6.1.4.1.6876.120.1.0.45.0.14NotificationvmwNsxTEdgeFailedToDeleteTheOldVMInvCenterDuringRedeployClearcurrentEdge node vmwNsxTDataCenterEntityId with stale VM moref id vmwNsxTDataCenterVMMorefId is not found anymore in both NSX inventory and vCenter. New deployed VM w…
1.3.6.1.4.1.6876.120.1.0.45.0.15NotificationvmwNsxTEdgeEdgeHardwareVersionMismatchcurrentThe Edge node vmwNsxTDataCenterTransportNodeName in Edge cluster vmwNsxTDataCenterEdgeClusterName has a hardware version vmwNsxTDataCenterEdgeTNHwVersion, whic…
1.3.6.1.4.1.6876.120.1.0.45.0.16NotificationvmwNsxTEdgeEdgeHardwareVersionMismatchClearcurrentThe Edge node vmwNsxTDataCenterTransportNodeName hardware version mismatch is resolved now. Action required: None, receipt of this notification indicates event…
1.3.6.1.4.1.6876.120.1.0.46IdentityvmwNsxTNATFeaturePrefixcurrentNotifications applicable to the NAT feature have this OID prefix.
1.3.6.1.4.1.6876.120.1.0.46.0IdentityvmwNsxTNATFeaturecurrentSub-identifier added to ensure the next-to-last sub-identifier is zero for NAT feature notifications.
1.3.6.1.4.1.6876.120.1.0.46.0.1NotificationvmwNsxTNATSNATPortUsageOnGatewayIsHighcurrentSNAT ports usage on logical router vmwNsxTDataCenterEntityId for SNAT IP vmwNsxTDataCenterSNATIPAddress has reached the high threshold value of vmwNsxTDataCent…
1.3.6.1.4.1.6876.120.1.0.46.0.2NotificationvmwNsxTNATSNATPortUsageOnGatewayIsHighClearcurrentSNAT ports usage on logical router vmwNsxTDataCenterEntityId for SNAT IP vmwNsxTDataCenterSNATIPAddress has reached below the high threshold value of vmwNsxTDa…
1.3.6.1.4.1.6876.120.1.0.47IdentityvmwNsxTPhysicalServerFeaturePrefixcurrentNotifications applicable to the PhysicalServer feature have this OID prefix.
1.3.6.1.4.1.6876.120.1.0.47.0IdentityvmwNsxTPhysicalServerFeaturecurrentSub-identifier added to ensure the next-to-last sub-identifier is zero for PhysicalServer feature notifications.
1.3.6.1.4.1.6876.120.1.0.47.0.1NotificationvmwNsxTPhysicalServerPhysicalServerInstallFailedcurrentPhysical Server vmwNsxTDataCenterTransportNodeName (vmwNsxTDataCenterEntityId) installation failed. Action required: Navigate to System > Fabric > Nodes > Host…
1.3.6.1.4.1.6876.120.1.0.47.0.2NotificationvmwNsxTPhysicalServerPhysicalServerInstallFailedClearcurrentPhysical Server vmwNsxTDataCenterTransportNodeName (vmwNsxTDataCenterEntityId) installation completed. Action required: None, receipt of this notification indi…
1.3.6.1.4.1.6876.120.1.0.47.0.3NotificationvmwNsxTPhysicalServerPhysicalServerUninstallFailedcurrentPhysical Server vmwNsxTDataCenterTransportNodeName (vmwNsxTDataCenterEntityId) uninstallation failed. Action required: Navigate to System > Fabric > Nodes > Ho…
1.3.6.1.4.1.6876.120.1.0.47.0.4NotificationvmwNsxTPhysicalServerPhysicalServerUninstallFailedClearcurrentPhysical Server vmwNsxTDataCenterTransportNodeName (vmwNsxTDataCenterEntityId) uninstallation completed. Action required: None, receipt of this notification in…
1.3.6.1.4.1.6876.120.1.0.47.0.5NotificationvmwNsxTPhysicalServerPhysicalServerUpgradeFailedcurrentPhysical Server vmwNsxTDataCenterTransportNodeName (vmwNsxTDataCenterEntityId) upgrade failed. Action required: Navigate to System > Upgrade and resolve the er…
1.3.6.1.4.1.6876.120.1.0.47.0.6NotificationvmwNsxTPhysicalServerPhysicalServerUpgradeFailedClearcurrentPhysical Server vmwNsxTDataCenterTransportNodeName (vmwNsxTDataCenterEntityId) upgrade completed. Action required: None, receipt of this notification indicates…
1.3.6.1.4.1.6876.120.1.0.48IdentityvmwNsxTMalwarePreventionHealthFeaturePrefixcurrentNotifications applicable to the MalwarePreventionHealth feature have this OID prefix.
1.3.6.1.4.1.6876.120.1.0.48.0IdentityvmwNsxTMalwarePreventionHealthFeaturecurrentSub-identifier added to ensure the next-to-last sub-identifier is zero for MalwarePreventionHealth feature notifications.
1.3.6.1.4.1.6876.120.1.0.48.0.1NotificationvmwNsxTMalwarePreventionHealthAnalystAPIServiceUnreachablecurrentService vmwNsxTDataCenterMpsServiceName is degraded on NSX Application Platform. It is unable to communicate with analyst_api service. Inspected file verdicts …
1.3.6.1.4.1.6876.120.1.0.48.0.2NotificationvmwNsxTMalwarePreventionHealthAnalystAPIServiceUnreachableClearcurrentService vmwNsxTDataCenterMpsServiceName is running properly on NSX Application Platform. Action required: None, receipt of this notification indicates event cl…
1.3.6.1.4.1.6876.120.1.0.48.0.3NotificationvmwNsxTMalwarePreventionHealthDatabaseUnreachablecurrentService vmwNsxTDataCenterMpsServiceName is degraded on NSX Application Platform. It is unable to communicate with Malware Prevention database. Action required:…
1.3.6.1.4.1.6876.120.1.0.48.0.4NotificationvmwNsxTMalwarePreventionHealthDatabaseUnreachableClearcurrentService vmwNsxTDataCenterMpsServiceName is running properly on NSX Application Platform. Action required: None, receipt of this notification indicates event cl…
1.3.6.1.4.1.6876.120.1.0.48.0.5NotificationvmwNsxTMalwarePreventionHealthFileExtractSvcUnreachablecurrentService vmwNsxTDataCenterMpsServiceName is degraded on vmwNsxTDataCenterTransportNodeName. Unable to communicate with file extraction functionality. All file e…
1.3.6.1.4.1.6876.120.1.0.48.0.6NotificationvmwNsxTMalwarePreventionHealthFileExtractSvcUnreachableClearcurrentService vmwNsxTDataCenterMpsServiceName is running properly on vmwNsxTDataCenterTransportNodeName. Action required: None, receipt of this notification indicate…
1.3.6.1.4.1.6876.120.1.0.48.0.7NotificationvmwNsxTMalwarePreventionHealthNTICSRepSvcUnreachablecurrentService vmwNsxTDataCenterMpsServiceName is degraded on NSX Application Platform. It is unable to communicate with NTICS reputation service. Inspected file repu…
1.3.6.1.4.1.6876.120.1.0.48.0.8NotificationvmwNsxTMalwarePreventionHealthNTICSRepSvcUnreachableClearcurrentService vmwNsxTDataCenterMpsServiceName is running properly on NSX Application Platform. Action required: None, receipt of this notification indicates event cl…
1.3.6.1.4.1.6876.120.1.0.48.0.9NotificationvmwNsxTMalwarePreventionHealthServiceStatusDowncurrentService vmwNsxTDataCenterMpsServiceName is not running on vmwNsxTDataCenterTransportNodeName. Action required: 1. On the Edge node identified by vmwNsxTDataCen…
1.3.6.1.4.1.6876.120.1.0.48.0.10NotificationvmwNsxTMalwarePreventionHealthServiceStatusDownClearcurrentService vmwNsxTDataCenterMpsServiceName is running properly on vmwNsxTDataCenterTransportNodeName. Action required: None, receipt of this notification indicate…
1.3.6.1.4.1.6876.120.1.0.49IdentityvmwNsxTEdgeClusterFeaturePrefixcurrentNotifications applicable to the EdgeCluster feature have this OID prefix.
1.3.6.1.4.1.6876.120.1.0.49.0IdentityvmwNsxTEdgeClusterFeaturecurrentSub-identifier added to ensure the next-to-last sub-identifier is zero for EdgeCluster feature notifications.
1.3.6.1.4.1.6876.120.1.0.49.0.5NotificationvmwNsxTEdgeClusterEdgeClusterMemberRelocateFailurecurrentThe operation on Edge cluster vmwNsxTDataCenterEdgeClusterId to relocate all service context failed for Edge cluster member index vmwNsxTDataCenterMemberIndexI…
1.3.6.1.4.1.6876.120.1.0.49.0.6NotificationvmwNsxTEdgeClusterEdgeClusterMemberRelocateFailureClearcurrentEdge node with vmwNsxTDataCenterTransportNodeId relocation failure has been resolved now. Action required: None, receipt of this notification indicates event c…
1.3.6.1.4.1.6876.120.1.0.50IdentityvmwNsxTVMCAppFeaturePrefixcurrentNotifications applicable to the VMCApp feature have this OID prefix.
1.3.6.1.4.1.6876.120.1.0.50.0IdentityvmwNsxTVMCAppFeaturecurrentSub-identifier added to ensure the next-to-last sub-identifier is zero for VMCApp feature notifications.
1.3.6.1.4.1.6876.120.1.0.50.0.1NotificationvmwNsxTVMCAppTransitConnectFailurecurrentTransit Connect related configuration is not fully correctly realized. Possible issues could be failing to retrieve provider information or some transient prov…
1.3.6.1.4.1.6876.120.1.0.50.0.2NotificationvmwNsxTVMCAppTransitConnectFailureClearcurrentTransit Connect failure is remediated. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.51IdentityvmwNsxTTEPHealthFeaturePrefixcurrentNotifications applicable to the TEPHealth feature have this OID prefix.
1.3.6.1.4.1.6876.120.1.0.51.0IdentityvmwNsxTTEPHealthFeaturecurrentSub-identifier added to ensure the next-to-last sub-identifier is zero for TEPHealth feature notifications.
1.3.6.1.4.1.6876.120.1.0.51.0.1NotificationvmwNsxTTEPHealthFaultyTEPcurrentTEP:vmwNsxTDataCenterVtepName of VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId. Overlay workloads using this TEP will face ne…
1.3.6.1.4.1.6876.120.1.0.51.0.2NotificationvmwNsxTTEPHealthFaultyTEPClearcurrentTEP:vmwNsxTDataCenterVtepName of VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId is healthy. Action required: None, receipt of …
1.3.6.1.4.1.6876.120.1.0.51.0.3NotificationvmwNsxTTEPHealthFaultyTEPOnDPUcurrentTEP:vmwNsxTDataCenterVtepName of VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId on DPU vmwNsxTDataCenterDPUId. Overlay workloa…
1.3.6.1.4.1.6876.120.1.0.51.0.4NotificationvmwNsxTTEPHealthFaultyTEPOnDPUClearcurrentTEP:vmwNsxTDataCenterVtepName of VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId on DPU vmwNsxTDataCenterDPUId is healthy. Acti…
1.3.6.1.4.1.6876.120.1.0.51.0.5NotificationvmwNsxTTEPHealthTEPAutorecoverFailurecurrentAuto Recover for TEP:vmwNsxTDataCenterVtepName of VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId failed. Overlay workloads usi…
1.3.6.1.4.1.6876.120.1.0.51.0.6NotificationvmwNsxTTEPHealthTEPAutorecoverFailureClearcurrentAuto Recover for TEP:vmwNsxTDataCenterVtepName of VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId is cleared. Action required: …
1.3.6.1.4.1.6876.120.1.0.51.0.7NotificationvmwNsxTTEPHealthTEPAutorecoverFailureOnDPUcurrentAuto Recover for TEP:vmwNsxTDataCenterVtepName of VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId on DPU vmwNsxTDataCenterDPUId…
1.3.6.1.4.1.6876.120.1.0.51.0.8NotificationvmwNsxTTEPHealthTEPAutorecoverFailureOnDPUClearcurrentAuto Recover for TEP:vmwNsxTDataCenterVtepName of VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId on DPU vmwNsxTDataCenterDPUId…
1.3.6.1.4.1.6876.120.1.0.51.0.9NotificationvmwNsxTTEPHealthTEPAutorecoverSuccesscurrentAuto Recover for TEP:vmwNsxTDataCenterVtepName of VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId is successful. Action require…
1.3.6.1.4.1.6876.120.1.0.51.0.10NotificationvmwNsxTTEPHealthTEPAutorecoverSuccessClearcurrentAuto Recover for TEP:vmwNsxTDataCenterVtepName of VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId is cleared. Action required: …
1.3.6.1.4.1.6876.120.1.0.51.0.11NotificationvmwNsxTTEPHealthTEPAutorecoverSuccessOnDPUcurrentAuto Recover for TEP:vmwNsxTDataCenterVtepName of VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId. on DPU vmwNsxTDataCenterDPUI…
1.3.6.1.4.1.6876.120.1.0.51.0.12NotificationvmwNsxTTEPHealthTEPAutorecoverSuccessOnDPUClearcurrentAuto Recover for TEP:vmwNsxTDataCenterVtepName of VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId. on DPU vmwNsxTDataCenterDPUI…
1.3.6.1.4.1.6876.120.1.0.51.0.13NotificationvmwNsxTTEPHealthTEPHaActivatedcurrentTEP HA activated for TEP:vmwNsxTDataCenterVtepName of VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId. Action required: Enable …
1.3.6.1.4.1.6876.120.1.0.51.0.14NotificationvmwNsxTTEPHealthTEPHaActivatedClearcurrentTEP HA cleared for TEP:vmwNsxTDataCenterVtepName of VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId. Action required: None, rec…
1.3.6.1.4.1.6876.120.1.0.51.0.15NotificationvmwNsxTTEPHealthTEPHaActivatedOnDPUcurrentTEP HA activated for TEP:vmwNsxTDataCenterVtepName of VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId on DPU vmwNsxTDataCenterD…
1.3.6.1.4.1.6876.120.1.0.51.0.16NotificationvmwNsxTTEPHealthTEPHaActivatedOnDPUClearcurrentTEP HA cleared for TEP:vmwNsxTDataCenterVtepName of VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId on DPU vmwNsxTDataCenterDPU…
1.3.6.1.4.1.6876.120.1.0.53IdentityvmwNsxTPolicyConstraintFeaturePrefixcurrentNotifications applicable to the PolicyConstraint feature have this OID prefix.
1.3.6.1.4.1.6876.120.1.0.53.0IdentityvmwNsxTPolicyConstraintFeaturecurrentSub-identifier added to ensure the next-to-last sub-identifier is zero for PolicyConstraint feature notifications.
1.3.6.1.4.1.6876.120.1.0.53.0.1NotificationvmwNsxTPolicyConstraintCreationCountLimitReachedcurrentEntity count for type vmwNsxTDataCenterConstraintType in vmwNsxTDataCenterConstraintTypePath is currently at vmwNsxTDataCenterCurrentCount which reached the ma…
1.3.6.1.4.1.6876.120.1.0.53.0.2NotificationvmwNsxTPolicyConstraintCreationCountLimitReachedClearcurrentvmwNsxTDataCenterConstraintType Count is below threshold. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.54IdentityvmwNsxTGroupsFeaturePrefixcurrentNotifications applicable to the Groups feature have this OID prefix.
1.3.6.1.4.1.6876.120.1.0.54.0IdentityvmwNsxTGroupsFeaturecurrentSub-identifier added to ensure the next-to-last sub-identifier is zero for Groups feature notifications.
1.3.6.1.4.1.6876.120.1.0.54.0.3NotificationvmwNsxTGroupsGroupSizeLimitExceededcurrentGroup vmwNsxTDataCenterGroupId has at least vmwNsxTDataCenterGroupSize translated elements which is at or greater than the maximum numbers limit of vmwNsxTData…
1.3.6.1.4.1.6876.120.1.0.54.0.4NotificationvmwNsxTGroupsGroupSizeLimitExceededClearcurrentTotal number of elements in group vmwNsxTDataCenterGroupId is below the maximum limit of vmwNsxTDataCenterGroupMaxNumberLimit. Action required: None, receipt o…
1.3.6.1.4.1.6876.120.1.0.56IdentityvmwNsxTSecurityComplianceFeaturePrefixcurrentNotifications applicable to the SecurityCompliance feature have this OID prefix.
1.3.6.1.4.1.6876.120.1.0.56.0IdentityvmwNsxTSecurityComplianceFeaturecurrentSub-identifier added to ensure the next-to-last sub-identifier is zero for SecurityCompliance feature notifications.
1.3.6.1.4.1.6876.120.1.0.56.0.1NotificationvmwNsxTSecurityCompliancePollEAL4NonCompliancecurrentOne of the EAL4+ compliance requirements is being violated. That means the NSX configuration is currently non-compliant with regards to EAL4+. Action required:…
1.3.6.1.4.1.6876.120.1.0.56.0.2NotificationvmwNsxTSecurityCompliancePollEAL4NonComplianceClearcurrentThe EAL4+ compliance issues have all been resolved. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.56.0.3NotificationvmwNsxTSecurityCompliancePollNDcPPNonCompliancecurrentOne of the NDcPP compliance requirements is being violated. That means the NSX configuration is currently non-compliant with regards to NDcPP. Action required:…
1.3.6.1.4.1.6876.120.1.0.56.0.4NotificationvmwNsxTSecurityCompliancePollNDcPPNonComplianceClearcurrentThe NDcPP compliance issues have all been resolved. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.56.0.5NotificationvmwNsxTSecurityComplianceTriggerEAL4NonCompliancecurrentOne of the EAL4+ compliance requirements is being violated. That means the NSX status is currently non-compliant with regards to EAL4+. Action required: Run th…
1.3.6.1.4.1.6876.120.1.0.56.0.6NotificationvmwNsxTSecurityComplianceTriggerEAL4NonComplianceClearcurrentThe EAL4+ compliance issues have all been resolved. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.0.56.0.7NotificationvmwNsxTSecurityComplianceTriggerNDcPPNonCompliancecurrentOne of the NDcPP compliance requirements is being violated. That means the NSX status is currently non-compliant with regards to NDcPP. Action required: Run th…
1.3.6.1.4.1.6876.120.1.0.56.0.8NotificationvmwNsxTSecurityComplianceTriggerNDcPPNonComplianceClearcurrentThe NDcPP compliance issues have all been resolved. Action required: None, receipt of this notification indicates event cleared.
1.3.6.1.4.1.6876.120.1.1IdentityvmwNsxTDataCenterDatacurrentAll variables that are sent in NSX Data Center event notifications fall under this oid.
1.3.6.1.4.1.6876.120.1.1.1ScalarvmwNsxTDataCenterTimestampaccessible-for-notifycurrentThe timestamp when the NSX Data Center event occurred.
1.3.6.1.4.1.6876.120.1.1.2ScalarvmwNsxTDataCenterFeatureNameaccessible-for-notifycurrentThe NSX Data Center feature ID associated with the event.
1.3.6.1.4.1.6876.120.1.1.3ScalarvmwNsxTDataCenterEventTypeaccessible-for-notifycurrentThe name of the NSX Data Center event.
1.3.6.1.4.1.6876.120.1.1.4ScalarvmwNsxTDataCenterEventSeverityaccessible-for-notifycurrentThe severity of the NSX Data Center event.
1.3.6.1.4.1.6876.120.1.1.5ScalarvmwNsxTDataCenterNodeIdaccessible-for-notifycurrentThe node ID from where a NSX Data Center event was emitted.
1.3.6.1.4.1.6876.120.1.1.6ScalarvmwNsxTDataCenterNodeTypeaccessible-for-notifycurrentThe type of node from where a NSX Data Center event was emitted.
1.3.6.1.4.1.6876.120.1.1.21ScalarvmwNsxTDataCenterEntityIdaccessible-for-notifycurrentThe ID of a NSX Data Center entity an event pertains to. The event description field provides additional details of the entity. For example the ID can be for a…
1.3.6.1.4.1.6876.120.1.1.22ScalarvmwNsxTDataCenterSystemResourceUsageaccessible-for-notifycurrentThe CPU, memory, or disk usage percentage of an NSX appliance. The value is an integer between 0 and 100.
1.3.6.1.4.1.6876.120.1.1.23ScalarvmwNsxTDataCenterDiskPartitionNameaccessible-for-notifycurrentThe name of a disk partition in an NSX appliance. For example, the name for the /tmp partition is '/tmp'.
1.3.6.1.4.1.6876.120.1.1.24ScalarvmwNsxTDataCenterLicenseEditionTypeaccessible-for-notifycurrentThe edition type of an NSX license. For example, the type for an NSX evaluation license is 'NSX Data Center Evaluation'.
1.3.6.1.4.1.6876.120.1.1.25ScalarvmwNsxTDataCenterApplianceAddressaccessible-for-notifycurrentThe NSX appliance's IP address. The value is an IPv4 address.
1.3.6.1.4.1.6876.120.1.1.26ScalarvmwNsxTDataCenterCurrentGatewayStateaccessible-for-notifycurrentThe current gateway state. The value could be 0, 1 or 2 where 0 is down, 1 is standby and 2 is active
1.3.6.1.4.1.6876.120.1.1.27ScalarvmwNsxTDataCenterCurrentServiceStateaccessible-for-notifycurrentThe current service state. The value could be start/stop/restart/crashed.
1.3.6.1.4.1.6876.120.1.1.28ScalarvmwNsxTDataCenterDatapathResourceUsageaccessible-for-notifycurrentThe CPU, memory, or disk usage percentage of the datapath on a NSX appliance. The value is an integer between 0 and 100.
1.3.6.1.4.1.6876.120.1.1.29ScalarvmwNsxTDataCenterDHCPPoolUsageaccessible-for-notifycurrentThe usage of a DHCP pool. The value is an integer between 0 and 100.
1.3.6.1.4.1.6876.120.1.1.30ScalarvmwNsxTDataCenterEdgeServiceNameaccessible-for-notifycurrentThe name of the service running on the Edge node.
1.3.6.1.4.1.6876.120.1.1.31ScalarvmwNsxTDataCenterFailureReasonaccessible-for-notifycurrentThe detailed reason of any module failure like BGP down, IKE down, etc.
1.3.6.1.4.1.6876.120.1.1.32ScalarvmwNsxTDataCenterPreviousGatewayStateaccessible-for-notifycurrentThe previous gateway state. The value could be 0, 1 or 2 where 0 is down, 1 is standby and 2 is active
1.3.6.1.4.1.6876.120.1.1.33ScalarvmwNsxTDataCenterPreviousServiceStateaccessible-for-notifycurrentThe previous service state. The value could be start/stop/restart/crashed.
1.3.6.1.4.1.6876.120.1.1.34ScalarvmwNsxTDataCenterSystemUsageThresholdaccessible-for-notifycurrentThe configured threshold value for the CPU, memory, or disk usage percentage of an NSX appliance. The value is an integer between 0 and 100.
1.3.6.1.4.1.6876.120.1.1.35ScalarvmwNsxTDataCenterUsernameaccessible-for-notifycurrentThe name of a user in an NSX appliance.
1.3.6.1.4.1.6876.120.1.1.36ScalarvmwNsxTDataCenterDHCPServerIdaccessible-for-notifycurrentThe UUID of a DHCP server.
1.3.6.1.4.1.6876.120.1.1.37ScalarvmwNsxTDataCenterServiceNameaccessible-for-notifycurrentThe name of the service running in an NSX appliance.
1.3.6.1.4.1.6876.120.1.1.38ScalarvmwNsxTDataCenterIntelligenceNodeIdaccessible-for-notifycurrentThe node ID of an NSX Intelligence node.
1.3.6.1.4.1.6876.120.1.1.39ScalarvmwNsxTDataCenterHostnameOrIPAddressWithPortaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.40ScalarvmwNsxTDataCenterEventIdaccessible-for-notifycurrentThe event identifier.
1.3.6.1.4.1.6876.120.1.1.41ScalarvmwNsxTDataCenterActiveGlobalManageraccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.42ScalarvmwNsxTDataCenterActiveGlobalManagersaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.43ScalarvmwNsxTDataCenterSessionDownReasonaccessible-for-notifycurrentDown reason of the IPsec VPN session.
1.3.6.1.4.1.6876.120.1.1.44ScalarvmwNsxTDataCenterManagerNodeNameaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.45ScalarvmwNsxTDataCenterTransportNodeAddressaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.46ScalarvmwNsxTDataCenterTransportNodeNameaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.47ScalarvmwNsxTDataCenterCentralControlPlaneIdaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.48ScalarvmwNsxTDataCenterTunnelDownReasonaccessible-for-notifycurrentDown reason of the IPsec VPN tunnel.
1.3.6.1.4.1.6876.120.1.1.49ScalarvmwNsxTDataCenterHeapTypeaccessible-for-notifycurrentHeap type information for DFW memory usage like vsip-attr, vsip-flow, vsip-fqdni, etc.
1.3.6.1.4.1.6876.120.1.1.50ScalarvmwNsxTDataCenterMempoolNameaccessible-for-notifycurrentName of a memory pool.
1.3.6.1.4.1.6876.120.1.1.51ScalarvmwNsxTDataCenterPasswordExpirationDaysaccessible-for-notifycurrentThe number of days left before expiration of the password of an NSX appliance user. The value is an integer greater than 0.
1.3.6.1.4.1.6876.120.1.1.52ScalarvmwNsxTDataCenterBGPNeighborIPaccessible-for-notifycurrentIP address of BGP Neighbor. This could be either IPv4 or IPv6 address.
1.3.6.1.4.1.6876.120.1.1.53ScalarvmwNsxTDataCenterLDAPServeraccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.54ScalarvmwNsxTDataCenterPeerAddressaccessible-for-notifycurrentIP address of BFD peer.
1.3.6.1.4.1.6876.120.1.1.55ScalarvmwNsxTDataCenterMaxIDSEventsAllowedaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.56ScalarvmwNsxTDataCenterStaticAddressaccessible-for-notifycurrentA Static IP address.
1.3.6.1.4.1.6876.120.1.1.57ScalarvmwNsxTDataCenterDuplicateIPAddressaccessible-for-notifycurrentDuplicate IP address.
1.3.6.1.4.1.6876.120.1.1.58ScalarvmwNsxTDataCenterCapacityDisplayNameaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.59ScalarvmwNsxTDataCenterCapacityUsageCountaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.60ScalarvmwNsxTDataCenterEdgeNICNameaccessible-for-notifycurrentThe name of the NIC whose link is down or which faced tx/rx ring buffer overflow.
1.3.6.1.4.1.6876.120.1.1.61ScalarvmwNsxTDataCenterRxRingBufferOverflowPercentageaccessible-for-notifycurrentThe NIC's receive descriptor ring buffer on a NSX Edge or Gateway node has no space left to accomodate new incoming packets and there is a significant drop due…
1.3.6.1.4.1.6876.120.1.1.62ScalarvmwNsxTDataCenterTxRingBufferOverflowPercentageaccessible-for-notifycurrentThe NIC's transmit descriptor ring buffer on a NSX Edge or Gateway node has no space left to accomodate new outgoing packets and there is a significant drop du…
1.3.6.1.4.1.6876.120.1.1.63ScalarvmwNsxTDataCenterSrIdaccessible-for-notifycurrentService Router UUID.
1.3.6.1.4.1.6876.120.1.1.64ScalarvmwNsxTDataCenterIDSEventsCountaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.65ScalarvmwNsxTDataCenterRemoteSiteNameaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.66ScalarvmwNsxTDataCenterBGPSourceIPaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.67ScalarvmwNsxTDataCenterRemoteSiteIdaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.68ScalarvmwNsxTDataCenterSiteIdaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.69ScalarvmwNsxTDataCenterSiteNameaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.70ScalarvmwNsxTDataCenterLrIdaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.71ScalarvmwNsxTDataCenterRxMissesaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.72ScalarvmwNsxTDataCenterRxProcessedaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.73ScalarvmwNsxTDataCenterTxMissesaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.74ScalarvmwNsxTDataCenterTxProcessedaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.75ScalarvmwNsxTDataCenterLrportIdaccessible-for-notifycurrentLogical Router Port UUID.
1.3.6.1.4.1.6876.120.1.1.77ScalarvmwNsxTDataCenterServiceIPaccessible-for-notifycurrentThe Ip configured for the service running in an NSX appliance.
1.3.6.1.4.1.6876.120.1.1.80ScalarvmwNsxTDataCenterRemoteManagerNodeIdaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.81ScalarvmwNsxTDataCenterDirectoryDomainaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.82ScalarvmwNsxTDataCenterTimeoutInMinutesaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.83ScalarvmwNsxTDataCenterMaxCapacityThresholdaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.84ScalarvmwNsxTDataCenterMinCapacityThresholdaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.85ScalarvmwNsxTDataCenterMaxSupportedCapacityCountaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.86ScalarvmwNsxTDataCenterLatencySourceaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.87ScalarvmwNsxTDataCenterLatencyThresholdaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.88ScalarvmwNsxTDataCenterLatencyValueaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.89ScalarvmwNsxTDataCenterApplianceFQDNaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.90ScalarvmwNsxTDataCenterRemoteApplianceAddressaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.91ScalarvmwNsxTDataCenterManagerNodeIdaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.92ScalarvmwNsxTDataCenterDisplayedLicenseKeyaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.93ScalarvmwNsxTDataCenterEdgeThreadNameaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.94ScalarvmwNsxTDataCenterIntentPathaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.95ScalarvmwNsxTDataCenterFirewallHalfopenFlowUsageaccessible-for-notifycurrentFirewall TCP half-open connection usage.
1.3.6.1.4.1.6876.120.1.1.96ScalarvmwNsxTDataCenterFirewallICMPFlowUsageaccessible-for-notifycurrentFirewall ICMP connection usage.
1.3.6.1.4.1.6876.120.1.1.97ScalarvmwNsxTDataCenterServiceDownReasonaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.98ScalarvmwNsxTDataCenterFirewallUDPFlowUsageaccessible-for-notifycurrentFirewall UDP connection usage.
1.3.6.1.4.1.6876.120.1.1.99ScalarvmwNsxTDataCenterFirewallIPFlowUsageaccessible-for-notifycurrentFirewall IP connection usage.
1.3.6.1.4.1.6876.120.1.1.100ScalarvmwNsxTDataCenterDNSIdaccessible-for-notifycurrentDNS forwarder identifier.
1.3.6.1.4.1.6876.120.1.1.101ScalarvmwNsxTDataCenterDNSUpstreamIPaccessible-for-notifycurrentDNS forwarder upstream server IP address.
1.3.6.1.4.1.6876.120.1.1.121ScalarvmwNsxTDataCenterCABundleAgeThresholdaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.122ScalarvmwNsxTDataCenterAPICollectionPathaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.123ScalarvmwNsxTDataCenterEdgeNodeSettingMismatchReasonaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.124ScalarvmwNsxTDataCenterEdgeVMvSphereSettingsMismatchReasonaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.125ScalarvmwNsxTDataCenterFirewallSNATPortsUsageaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.126ScalarvmwNsxTDataCenterEdgevSphereLocationMismatchReasonaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.127ScalarvmwNsxTDataCenterEdgeNodeAndvSphereSettingsMismatchReasonaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.128ScalarvmwNsxTDataCenterSNATIPAddressaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.129ScalarvmwNsxTDataCenterNappClusterIdaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.130ScalarvmwNsxTDataCenterNappMessagingLAGThresholdaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.131ScalarvmwNsxTDataCenterNappNodeIdaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.132ScalarvmwNsxTDataCenterNappServiceNameaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.133ScalarvmwNsxTDataCenterFlowIdentifieraccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.134ScalarvmwNsxTDataCenterSyncIssueReasonaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.135ScalarvmwNsxTDataCenterQueueNameaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.136ScalarvmwNsxTDataCenterQueueSizeaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.137ScalarvmwNsxTDataCenterQueueSizeThresholdaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.138ScalarvmwNsxTDataCenterGroupTypeaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.139ScalarvmwNsxTDataCenterManagerNodeIDSaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.140ScalarvmwNsxTDataCenterServiceRouterIdaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.141ScalarvmwNsxTDataCenterTransportNodeIdaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.142ScalarvmwNsxTDataCenterFromGMPathaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.143ScalarvmwNsxTDataCenterToGMPathaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.144ScalarvmwNsxTDataCenterNICThroughputaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.145ScalarvmwNsxTDataCenterNICThroughputThresholdaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.146ScalarvmwNsxTDataCenterEdgeCryptoDrvNameaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.147ScalarvmwNsxTDataCenterNappNodeNameaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.148ScalarvmwNsxTDataCenterNewVMMorefIdaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.149ScalarvmwNsxTDataCenterPolicyEdgeVMNameaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.150ScalarvmwNsxTDataCenterVMMorefIdaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.171ScalarvmwNsxTDataCenterDPUIdaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.172ScalarvmwNsxTDataCenterEdgeNodeaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.173ScalarvmwNsxTDataCenterPrefixesCountMaxaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.174ScalarvmwNsxTDataCenterPrefixesCountThresholdaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.175ScalarvmwNsxTDataCenterRouteLimitMaximumaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.176ScalarvmwNsxTDataCenterRouteLimitThresholdaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.177ScalarvmwNsxTDataCenterSubsequentAddressFamilyaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.179ScalarvmwNsxTDataCentervCenterClusterIdaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.180ScalarvmwNsxTDataCenterMpsServiceNameaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.182ScalarvmwNsxTDataCenterMemberIndexIdaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.184ScalarvmwNsxTDataCenterEdgeClusterIdaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.185ScalarvmwNsxTDataCenterCoreDumpCountaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.186ScalarvmwNsxTDataCenterNodeDisplayOrHostNameaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.187ScalarvmwNsxTDataCenterNSXEdgeTNNameaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.188ScalarvmwNsxTDataCenterNSXESXTNNameaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.189ScalarvmwNsxTDataCenterCollectorIPaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.190ScalarvmwNsxTDataCenterDvsAliasaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.191ScalarvmwNsxTDataCenterStackAliasaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.192ScalarvmwNsxTDataCenterVerticalNameaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.195ScalarvmwNsxTDataCenterEdgeClusterHighestHwVersionaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.196ScalarvmwNsxTDataCenterEdgeTNHwVersionaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.197ScalarvmwNsxTDataCenterEdgeClusterNameaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.220ScalarvmwNsxTDataCenterHaStateaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.221ScalarvmwNsxTDataCenterHaState2accessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.222ScalarvmwNsxTDataCenterTransportNodeId2accessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.223ScalarvmwNsxTDataCenterDvsNameaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.224ScalarvmwNsxTDataCenterVtepFaultReasonaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.225ScalarvmwNsxTDataCenterVtepNameaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.226ScalarvmwNsxTDataCenterMetricsTargetAddressaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.227ScalarvmwNsxTDataCenterMetricsTargetAliasaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.228ScalarvmwNsxTDataCenterMetricsTargetPortaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.229ScalarvmwNsxTDataCenterIPv4Addressaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.230ScalarvmwNsxTDataCenterIPv6Addressaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.231ScalarvmwNsxTDataCenterConstraintLimitaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.232ScalarvmwNsxTDataCenterConstraintTypeaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.233ScalarvmwNsxTDataCenterCurrentCountaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.234ScalarvmwNsxTDataCenterGroupIdaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.235ScalarvmwNsxTDataCenterGroupMaxNumberLimitaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.236ScalarvmwNsxTDataCenterGroupSizeaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.237ScalarvmwNsxTDataCenterIPCountaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.238ScalarvmwNsxTDataCenterLrpCountaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.239ScalarvmwNsxTDataCenterLspCountaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.240ScalarvmwNsxTDataCenterMacCountaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.241ScalarvmwNsxTDataCenterSidCountaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.244ScalarvmwNsxTDataCenterTNCountaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.245ScalarvmwNsxTDataCenterVifCountaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.246ScalarvmwNsxTDataCenterVMCountaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.247ScalarvmwNsxTDataCenterCoreIdaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.248ScalarvmwNsxTDataCenterFlowCacheThresholdaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.249ScalarvmwNsxTDataCenterNSXaaSServiceNameaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.250ScalarvmwNsxTDataCenterProtocolNameaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.1.251ScalarvmwNsxTDataCenterConstraintTypePathaccessible-for-notifycurrentThis value is not expected to be empty.
1.3.6.1.4.1.6876.120.1.2NodevmwNsxTDataCenterConformance
1.3.6.1.4.1.6876.120.1.2.1NodevmwNsxTDataCenterCompliances
1.3.6.1.4.1.6876.120.1.2.1.1CompliancevmwNsxTDataCenterBasicCompliancedeprecatedThe compliance statement for entities which implement VMWARE-NSX-MIB.
1.3.6.1.4.1.6876.120.1.2.1.2CompliancevmwNsxTDataCenterBasicCompliance2deprecatedThe compliance statement for entities which implement VMWARE-NSX-MIB.
1.3.6.1.4.1.6876.120.1.2.1.3CompliancevmwNsxTDataCenterBasicCompliance3deprecatedThe compliance statement for entities which implement VMWARE-NSX-MIB.
1.3.6.1.4.1.6876.120.1.2.1.4CompliancevmwNsxTDataCenterBasicCompliance4deprecatedThe compliance statement for entities which implement VMWARE-NSX-MIB.
1.3.6.1.4.1.6876.120.1.2.1.5CompliancevmwNsxTDataCenterBasicCompliance5deprecatedThe compliance statement for entities which implement VMWARE-NSX-MIB.
1.3.6.1.4.1.6876.120.1.2.1.6CompliancevmwNsxTDataCenterBasicCompliance6deprecatedThe compliance statement for entities which implement VMWARE-NSX-MIB.
1.3.6.1.4.1.6876.120.1.2.1.7CompliancevmwNsxTDataCenterBasicCompliance7deprecatedThe compliance statement for entities which implement VMWARE-NSX-MIB.
1.3.6.1.4.1.6876.120.1.2.1.8CompliancevmwNsxTDataCenterBasicCompliance8deprecatedThe compliance statement for entities which implement VMWARE-NSX-MIB.
1.3.6.1.4.1.6876.120.1.2.1.9CompliancevmwNsxTDataCenterBasicCompliance9deprecatedThe compliance statement for entities which implement VMWARE-NSX-MIB.
1.3.6.1.4.1.6876.120.1.2.1.10CompliancevmwNsxTDataCenterBasicCompliance10deprecatedThe compliance statement for entities which implement VMWARE-NSX-MIB.
1.3.6.1.4.1.6876.120.1.2.1.11CompliancevmwNsxTDataCenterBasicCompliance11deprecatedThe compliance statement for entities which implement VMWARE-NSX-MIB.
1.3.6.1.4.1.6876.120.1.2.1.12CompliancevmwNsxTDataCenterBasicCompliance12deprecatedThe compliance statement for entities which implement VMWARE-NSX-MIB.
1.3.6.1.4.1.6876.120.1.2.1.13CompliancevmwNsxTDataCenterBasicCompliance13deprecatedThe compliance statement for entities which implement VMWARE-NSX-MIB.
1.3.6.1.4.1.6876.120.1.2.1.14CompliancevmwNsxTDataCenterBasicCompliance14currentThe compliance statement for entities which implement VMWARE-NSX-MIB.
1.3.6.1.4.1.6876.120.1.2.2NodevmwNsxTDataCenterSMIBGroups
1.3.6.1.4.1.6876.120.1.2.2.1GroupvmwNsxTDataCenterNotificationInfoGroupcurrentThese objects provide details in NSX Data Center event notifications.
1.3.6.1.4.1.6876.120.1.2.2.2GroupvmwNsxTDataCenterNotificationGroupcurrentGroup of objects describing event notifications emitted by NSX Data Center.
1.3.6.1.4.1.6876.120.1.2.2.3GroupvmwNsxTDataCenterNotificationInfoGroup2currentThese objects provide details in NSX Data Center event notifications.
1.3.6.1.4.1.6876.120.1.2.2.4GroupvmwNsxTDataCenterNotificationGroup2currentGroup of objects describing event notifications emitted by NSX Data Center.
1.3.6.1.4.1.6876.120.1.2.2.5GroupvmwNsxTDataCenterNotificationInfoGroup3currentThese objects provide details in NSX Data Center event notifications.
1.3.6.1.4.1.6876.120.1.2.2.6GroupvmwNsxTDataCenterNotificationGroup3currentGroup of objects describing event notifications emitted by NSX Data Center.
1.3.6.1.4.1.6876.120.1.2.2.7GroupvmwNsxTDataCenterNotificationInfoGroup4currentThese objects provide details in NSX Data Center event notifications.
1.3.6.1.4.1.6876.120.1.2.2.8GroupvmwNsxTDataCenterNotificationGroup4currentGroup of objects describing event notifications emitted by NSX Data Center.
1.3.6.1.4.1.6876.120.1.2.2.10GroupvmwNsxTDataCenterNotificationGroup5currentGroup of objects describing event notifications emitted by NSX Data Center.
1.3.6.1.4.1.6876.120.1.2.2.11GroupvmwNsxTDataCenterNotificationInfoGroup6currentThese objects provide details in NSX Data Center event notifications.
1.3.6.1.4.1.6876.120.1.2.2.12GroupvmwNsxTDataCenterNotificationGroup6currentGroup of objects describing event notifications emitted by NSX Data Center.
1.3.6.1.4.1.6876.120.1.2.2.13GroupvmwNsxTDataCenterNotificationInfoGroup7currentThese objects provide details in NSX Data Center event notifications.
1.3.6.1.4.1.6876.120.1.2.2.14GroupvmwNsxTDataCenterNotificationGroup7currentGroup of objects describing event notifications emitted by NSX Data Center.
1.3.6.1.4.1.6876.120.1.2.2.15GroupvmwNsxTDataCenterNotificationInfoGroup8currentThese objects provide details in NSX Data Center event notifications.
1.3.6.1.4.1.6876.120.1.2.2.16GroupvmwNsxTDataCenterNotificationGroup8currentGroup of objects describing event notifications emitted by NSX Data Center.
1.3.6.1.4.1.6876.120.1.2.2.17GroupvmwNsxTDataCenterNotificationInfoGroup9currentThese objects provide details in NSX Data Center event notifications.
1.3.6.1.4.1.6876.120.1.2.2.18GroupvmwNsxTDataCenterNotificationGroup9currentGroup of objects describing event notifications emitted by NSX Data Center.
1.3.6.1.4.1.6876.120.1.2.2.19GroupvmwNsxTDataCenterNotificationInfoGroup10currentThese objects provide details in NSX Data Center event notifications.
1.3.6.1.4.1.6876.120.1.2.2.20GroupvmwNsxTDataCenterNotificationGroup10currentGroup of objects describing event notifications emitted by NSX Data Center.
1.3.6.1.4.1.6876.120.1.2.2.21GroupvmwNsxTDataCenterNotificationInfoGroup11currentThese objects provide details in NSX-T Data Center event notifications.
1.3.6.1.4.1.6876.120.1.2.2.22GroupvmwNsxTDataCenterNotificationGroup11currentGroup of objects describing event notifications emitted by NSX-T Data Center.
1.3.6.1.4.1.6876.120.1.2.2.23GroupvmwNsxTDataCenterNotificationInfoGroup12currentThese objects provide details in NSX-T Data Center event notifications.
1.3.6.1.4.1.6876.120.1.2.2.24GroupvmwNsxTDataCenterNotificationGroup12currentGroup of objects describing event notifications emitted by NSX-T Data Center.
1.3.6.1.4.1.6876.120.1.2.2.25GroupvmwNsxTDataCenterNotificationInfoGroup13currentThese objects provide details in NSX-T Data Center event notifications.
1.3.6.1.4.1.6876.120.1.2.2.26GroupvmwNsxTDataCenterNotificationGroup13currentGroup of objects describing event notifications emitted by NSX-T Data Center.
1.3.6.1.4.1.6876.120.1.2.2.27GroupvmwNsxTDataCenterNotificationInfoGroup14currentThese objects provide details in NSX-T Data Center event notifications.
1.3.6.1.4.1.6876.120.1.2.2.28GroupvmwNsxTDataCenterNotificationGroup14currentGroup of objects describing event notifications emitted by NSX-T Data Center.
Type Definitions
NameSyntaxStatusDescription
VmwNsxTDataCenterActiveGlobalManagersTypeOCTET STRING (SIZE (0..256))currentA comma delimited list of identifiers for the active Global Manager nodes.
VmwNsxTDataCenterActiveGlobalManagerTypeOCTET STRING (SIZE (0..256))currentThe identifier for the active Global Manager node.
VmwNsxTDataCenterAPICollectionPathTypeOCTET STRING (SIZE (0..256))currentThe API path of the collection containing entity_id.
VmwNsxTDataCenterApplianceAddressTypeOCTET STRING (SIZE (0..256))currentThe NSX appliance's IP address. The value is an IPv4 address.
VmwNsxTDataCenterApplianceFQDNTypeOCTET STRING (SIZE (0..256))currentThe NSX appliance's fully qualified domain name.
VmwNsxTDataCenterBGPNeighborIPTypeOCTET STRING (SIZE (0..256))currentIP address of BGP Neighbor. This could be either IPv4 or IPv6 address.
VmwNsxTDataCenterBGPSourceIPTypeOCTET STRING (SIZE (0..256))currentSource IP address of BGP session. This could be either an IPv4 address in dotted-decimal format or an IPv6 address in IPv6 address format.
VmwNsxTDataCenterCABundleAgeThresholdTypeOCTET STRING (SIZE (0..256))currentThe age threshold in days for the CA bundle.
VmwNsxTDataCenterCapacityDisplayNameTypeOCTET STRING (SIZE (0..256))currentDisplay name of type on capacity dashboard.
VmwNsxTDataCenterCapacityUsageCountTypeOCTET STRING (SIZE (0..256))currentCurrent usage count of capacity usage type.
VmwNsxTDataCenterCentralControlPlaneIdTypeOCTET STRING (SIZE (0..256))currentThe UUID of a NSX centrol control plane.
VmwNsxTDataCenterCollectorIPTypeOCTET STRING (SIZE (0..256))currentExternal OPS collector IP address for OPS features.
VmwNsxTDataCenterConstraintLimitTypeOCTET STRING (SIZE (0..256))currentValue of constraint limit.
VmwNsxTDataCenterConstraintTypePathTypeOCTET STRING (SIZE (0..256))currentPath prefix of constraint resource.
VmwNsxTDataCenterConstraintTypeTypeOCTET STRING (SIZE (0..256))currentType of constraint resource.
VmwNsxTDataCenterCoreDumpCountTypeOCTET STRING (SIZE (0..256))currentThe number of core dump file generated in system.
VmwNsxTDataCenterCoreIdTypeOCTET STRING (SIZE (0..256))currentString to identify the core on which event is triggered.
VmwNsxTDataCenterCurrentCountTypeOCTET STRING (SIZE (0..256))currentCurrent count of object.
VmwNsxTDataCenterCurrentGatewayStateTypeOCTET STRING (SIZE (0..256))currentThe current gateway state. The value could be 0, 1 or 2 where 0 is down, 1 is standby and 2 is active
VmwNsxTDataCenterCurrentServiceStateTypeOCTET STRING (SIZE (0..256))currentThe current service state. The value could be start/stop/restart/crashed.
VmwNsxTDataCenterDatapathResourceUsageTypeOCTET STRING (SIZE (0..256))currentThe CPU, memory, or disk usage percentage of the datapath on a NSX appliance. The value is an integer between 0 and 100.
VmwNsxTDataCenterDHCPPoolUsageTypeOCTET STRING (SIZE (0..256))currentThe usage of a DHCP pool. The value is an integer between 0 and 100.
VmwNsxTDataCenterDHCPServerIdTypeOCTET STRING (SIZE (0..256))currentThe UUID of a DHCP server.
VmwNsxTDataCenterDirectoryDomainTypeOCTET STRING (SIZE (0..256))currentThe name of a directory domain.
VmwNsxTDataCenterDiskPartitionNameTypeOCTET STRING (SIZE (0..256))currentThe name of a disk partition in an NSX appliance. For example, the name for the /tmp partition is '/tmp'.
VmwNsxTDataCenterDisplayedLicenseKeyTypeOCTET STRING (SIZE (0..256))currentThe last 5 characters of the license key of an NSX license.
VmwNsxTDataCenterDNSIdTypeOCTET STRING (SIZE (0..256))currentThe DNS forwarder identifier.
VmwNsxTDataCenterDNSUpstreamIPTypeOCTET STRING (SIZE (0..256))currentIP address of one DNS forwarder upstream server.
VmwNsxTDataCenterDPUIdTypeOCTET STRING (SIZE (0..256))currentData processing unit identifier.
VmwNsxTDataCenterDuplicateIPAddressTypeOCTET STRING (SIZE (0..256))currentDuplicate IP address.
VmwNsxTDataCenterDvsAliasTypeOCTET STRING (SIZE (0..256))currentDVS name to indicate given DVS.
VmwNsxTDataCenterDvsNameTypeOCTET STRING (SIZE (0..256))currentThe ESXi DVS name.
VmwNsxTDataCenterEdgeClusterHighestHwVersionTypeOCTET STRING (SIZE (0..256))currentString containing highest hardware version of Edge Transport Node in edge cluster.
VmwNsxTDataCenterEdgeClusterIdTypeOCTET STRING (SIZE (0..256))currentString representing the edge cluster ID.
VmwNsxTDataCenterEdgeClusterNameTypeOCTET STRING (SIZE (0..256))currentString containing Edge cluster display name.
VmwNsxTDataCenterEdgeCryptoDrvNameTypeOCTET STRING (SIZE (0..256))currentName of the edge crypto driver.
VmwNsxTDataCenterEdgeNICNameTypeOCTET STRING (SIZE (0..256))currentThe name of the NIC whose link is down or which faced tx/rx ring buffer overflow.
VmwNsxTDataCenterEdgeNodeAndvSphereSettingsMismatchReasonTypeOCTET STRING (SIZE (0..256))currentString containing Policy/MP intent of Edge transport node settings and vSphere deployment configuration that differs from corresponding Edge transport node settings on Edge NSX CLI and Edge transport node configuration …
VmwNsxTDataCenterEdgeNodeSettingMismatchReasonTypeOCTET STRING (SIZE (0..256))currentString containing Policy/MP intent of Edge transport node settings that differs from corresponding Edge transport node settings on Edge NSX CLI.
VmwNsxTDataCenterEdgeNodeTypeOCTET STRING (SIZE (0..256))currentString representing the Edge node UUID.
VmwNsxTDataCenterEdgeServiceNameTypeOCTET STRING (SIZE (0..256))currentThe name of the service running on the Edge node.
VmwNsxTDataCenterEdgeThreadNameTypeOCTET STRING (SIZE (0..256))currentThe name of the Edge node thread.
VmwNsxTDataCenterEdgeTNHwVersionTypeOCTET STRING (SIZE (0..256))currentString containing hardware version of Edge Transport Node.
VmwNsxTDataCenterEdgeVMvSphereSettingsMismatchReasonTypeOCTET STRING (SIZE (0..256))currentString containing Policy/MP intent of Edge transport node vSphere deployment configuration that differs from corresponding Edge transport node configuration on vSphere.
VmwNsxTDataCenterEdgevSphereLocationMismatchReasonTypeOCTET STRING (SIZE (0..256))currentString containing Policy/MP intent of vSphere deployment configuration that differs from corresponding Edge transport node configuration on vSphere when vMotion happens for Edge node.
VmwNsxTDataCenterEntityIdTypeOCTET STRING (SIZE (0..256))currentThe ID of a NSX Data Center entity an event pertains to. The event description field provides additional details of the entity. For example the ID can be for a specific Load Balancer rule as reported by the NSX API GET …
VmwNsxTDataCenterEventIdTypeOCTET STRING (SIZE (0..256))currentThe event identifier.
VmwNsxTDataCenterEventTypeTypeOCTET STRING (SIZE (0..256))currentThe name of the NSX Data Center event. The complete set of events are reported by the NSX API GET /api/v1/events.
VmwNsxTDataCenterFailureReasonTypeOCTET STRING (SIZE (0..256))currentThe detailed reason of any module failure like BGP down, IKE down, etc.
VmwNsxTDataCenterFeatureIdTypeINTEGER { managerHealth(1), edgeHealth(2), certificates(3), passwordManagement(4), licenses(5), intelligenceHealth(6), infrastructureCommunication(7), intelligenceCommunication(9), cniHealth(10), ncpHealth(11), nodeAgentsHealth(12), endpointProtection(13), serviceInsertion(14), vpn(15), alarmManagement(16), loadBalancer(17), transportNodeHealth(18), infrastructureService(19), dhcp(20), highAvailability(21), capacity(22), auditLogHealth(24), routing(28), dns(30), distributedFirewall(31), federation(32), distributedIdsIps(33), communication(35), identityFirewall(36), ipam(38), gatewayFirewall(39), clustering(40), nsxApplicationPlatformCommunication(41), mtuCheck(42), nsxApplicationPlatformHealth(43), edge(45), nat(46), physicalServer(47), malwarePreventionHealth(48), edgeCluster(49), vmcApp(50), tepHealth(51), policyConstraint(53), groups(54), securityCompliance(56), nsxaasHealth(58) }currentThe NSX Data Center feature ID associated with the event. For example, this value identifies the feature is managerHealth, edgeHealth, loadBalancer, etc.
VmwNsxTDataCenterFirewallHalfopenFlowUsageTypeOCTET STRING (SIZE (0..256))currentCurrent firewall TCP half-open connection usage percentage of max supported value. The value is an integer between 0 and 100.
VmwNsxTDataCenterFirewallICMPFlowUsageTypeOCTET STRING (SIZE (0..256))currentCurrent firewall ICMP connection usage percentage of max supported value. The value is an integer between 0 and 100.
VmwNsxTDataCenterFirewallIPFlowUsageTypeOCTET STRING (SIZE (0..256))currentCurrent firewall IP connection usage percentage of max supported value. The value is an integer between 0 and 100.
VmwNsxTDataCenterFirewallSNATPortsUsageTypeOCTET STRING (SIZE (0..256))currentCurrent firewall SNAT ports usage percentage of max supported value. The value is an integer between 0 and 100.
VmwNsxTDataCenterFirewallUDPFlowUsageTypeOCTET STRING (SIZE (0..256))currentCurrent firewall UDP connection usage percentage of max supported value. The value is an integer between 0 and 100.
VmwNsxTDataCenterFlowCacheThresholdTypeOCTET STRING (SIZE (0..256))currentString to identify the flow cache threshold.
VmwNsxTDataCenterFlowIdentifierTypeOCTET STRING (SIZE (0..256))currentA flow identifier indicating the direction of flow of data which is one of following. - GM_2_LM - LM_2_GM_NOTIFICATION - LM_2_GM_ONBOARD_CONFIG
VmwNsxTDataCenterFromGMPathTypeOCTET STRING (SIZE (0..256))currentPolicy path of the Global Manager.
VmwNsxTDataCenterGroupIdTypeOCTET STRING (SIZE (0..256))currentThe group UUID.
VmwNsxTDataCenterGroupMaxNumberLimitTypeOCTET STRING (SIZE (0..256))currentMaximum number of group elements supported.
VmwNsxTDataCenterGroupSizeTypeOCTET STRING (SIZE (0..256))currentTotal number of group elements.
VmwNsxTDataCenterGroupTypeTypeOCTET STRING (SIZE (0..256))currentThe group type of a GMLE cluster.
VmwNsxTDataCenterHaState2TypeOCTET STRING (SIZE (0..256))currentThe current high-availability state. The value could be active/standby/down.
VmwNsxTDataCenterHaStateTypeOCTET STRING (SIZE (0..256))currentThe current high-availability state. The value could be active/standby/down.
VmwNsxTDataCenterHeapTypeTypeOCTET STRING (SIZE (0..256))currentHeap type information for DFW memory usage like vsip-attr, vsip-flow, vsip-fqdni, etc.
VmwNsxTDataCenterHostnameOrIPAddressWithPortTypeOCTET STRING (SIZE (0..256))currentHostname or ip address with port of logging server.
VmwNsxTDataCenterIDSEventsCountTypeOCTET STRING (SIZE (0..256))currentCount of the IDS events in the system currently.
VmwNsxTDataCenterIntelligenceNodeIdTypeOCTET STRING (SIZE (0..256))currentThe node ID of an NSX Intelligence node.
VmwNsxTDataCenterIntentPathTypeOCTET STRING (SIZE (0..256))currentThe policy intent path.
VmwNsxTDataCenterIPCountTypeOCTET STRING (SIZE (0..256))currentNumber of IP sets inside one group.
VmwNsxTDataCenterIPv4AddressTypeOCTET STRING (SIZE (0..256))currentName of IPv4 address in dual stack.
VmwNsxTDataCenterIPv6AddressTypeOCTET STRING (SIZE (0..256))currentName of IPv6 address in dual stack.
VmwNsxTDataCenterLatencySourceTypeOCTET STRING (SIZE (0..256))currentThe source of reported latency.
VmwNsxTDataCenterLatencyThresholdTypeOCTET STRING (SIZE (0..256))currentThreshold value of reported IO latency.
VmwNsxTDataCenterLatencyValueTypeOCTET STRING (SIZE (0..256))currentValue of reported IO latency.
VmwNsxTDataCenterLDAPServerTypeOCTET STRING (SIZE (0..256))currentThe name or IP address of a LDAP server.
VmwNsxTDataCenterLicenseEditionTypeTypeOCTET STRING (SIZE (0..256))currentThe edition type of an NSX license. For example, the type for an NSX evaluation license is 'NSX Data Center Evaluation'.
VmwNsxTDataCenterLrIdTypeOCTET STRING (SIZE (0..256))currentLogical Router UUID.
VmwNsxTDataCenterLrpCountTypeOCTET STRING (SIZE (0..256))currentNumber of logical router port inside one group.
VmwNsxTDataCenterLrportIdTypeOCTET STRING (SIZE (0..256))currentLogical Router Port UUID.
VmwNsxTDataCenterLspCountTypeOCTET STRING (SIZE (0..256))currentNumber of logical switch port inside one group.
VmwNsxTDataCenterMacCountTypeOCTET STRING (SIZE (0..256))currentNumber of MAC sets inside one group.
VmwNsxTDataCenterManagerNodeIDSTypeOCTET STRING (SIZE (0..256))currentA comma delimited list of identifiers for the Manager nodes.
VmwNsxTDataCenterManagerNodeIdTypeOCTET STRING (SIZE (0..256))currentThe Manager node UUID.
VmwNsxTDataCenterManagerNodeNameTypeOCTET STRING (SIZE (0..256))currentThe display name of a NSX Manager node.
VmwNsxTDataCenterMaxCapacityThresholdTypeOCTET STRING (SIZE (0..256))currentMaximum threshold defined for capacity usage type.
VmwNsxTDataCenterMaxIDSEventsAllowedTypeOCTET STRING (SIZE (0..256))currentThe maximum number of IDS events that are allowed in the system, anything beyond this would be purged at regular intervals.
VmwNsxTDataCenterMaxSupportedCapacityCountTypeOCTET STRING (SIZE (0..256))currentMaximum supported count for capacity usage type.
VmwNsxTDataCenterMemberIndexIdTypeOCTET STRING (SIZE (0..256))currentString representing member index ID.
VmwNsxTDataCenterMempoolNameTypeOCTET STRING (SIZE (0..256))currentName of a memory pool.
VmwNsxTDataCenterMetricsTargetAddressTypeOCTET STRING (SIZE (0..256))currentIP address of specified target metrics being delivered to.
VmwNsxTDataCenterMetricsTargetAliasTypeOCTET STRING (SIZE (0..256))currentAlias of specified target metrics being delivered to.
VmwNsxTDataCenterMetricsTargetPortTypeOCTET STRING (SIZE (0..256))currentListen port of specified target metrics being delivered to.
VmwNsxTDataCenterMinCapacityThresholdTypeOCTET STRING (SIZE (0..256))currentMinimum threshold defined for capacity usage type.
VmwNsxTDataCenterMpsServiceNameTypeOCTET STRING (SIZE (0..256))currentThe service name of an NSX Malware Prevention service.
VmwNsxTDataCenterNappClusterIdTypeOCTET STRING (SIZE (0..256))currentThe cluster ID of the NSX Application Platform cluster.
VmwNsxTDataCenterNappMessagingLAGThresholdTypeOCTET STRING (SIZE (0..256))currentThe configured threshold value for the number of pending messages in an NSX Application Platform messaging topic.
VmwNsxTDataCenterNappNodeIdTypeOCTET STRING (SIZE (0..256))currentThe node ID of an NSX Application Platform node.
VmwNsxTDataCenterNappNodeNameTypeOCTET STRING (SIZE (0..256))currentThe node name of an NSX Application Platform node.
VmwNsxTDataCenterNappServiceNameTypeOCTET STRING (SIZE (0..256))currentThe service name of an NSX Application Platform service.
VmwNsxTDataCenterNewVMMorefIdTypeOCTET STRING (SIZE (0..256))currentString containing Edge VM moref details corresponding to Policy/MP intent vSphere deployment configuration.
VmwNsxTDataCenterNICThroughputThresholdTypeOCTET STRING (SIZE (0..256))currentThe NIC throughput threshold, as a percentage. The value is an integer between 0 and 100.
VmwNsxTDataCenterNICThroughputTypeOCTET STRING (SIZE (0..256))currentThe NIC throughput, as a percentage. The value is an integer between 0 and 100.
VmwNsxTDataCenterNodeDisplayOrHostNameTypeOCTET STRING (SIZE (0..256))currentDisplay name or Host name of NSX node.
VmwNsxTDataCenterNodeIdTypeOCTET STRING (SIZE (0..256))currentThe node ID from where a NSX Data Center event was emitted. A node ID can be for a cluster node as reported by the NSX API GET /api/v1/cluster. Or a node ID can be for a transport node as reported by the NSX API GET /ap…
VmwNsxTDataCenterNodeTypeTypeINTEGER { manager(0), edge(1), esx(2), kvm(3), publiccloudgateway(4), intelligence(5), autonomousedge(6), globalmanager(7) }currentThe type of node from where a NSX Data Center event was emitted.
VmwNsxTDataCenterNSXaaSServiceNameTypeOCTET STRING (SIZE (0..256))currentThe name of the service running in NSXaaS.
VmwNsxTDataCenterNSXEdgeTNNameTypeOCTET STRING (SIZE (0..256))currentThe display name of a NSX Edge Transport node.
VmwNsxTDataCenterNSXESXTNNameTypeOCTET STRING (SIZE (0..256))currentThe display name of a NSX Host Transport node.
VmwNsxTDataCenterPasswordExpirationDaysTypeOCTET STRING (SIZE (0..256))currentThe number of days left before expiration of the password of an NSX appliance user. The value is an integer greater than 0.
VmwNsxTDataCenterPeerAddressTypeOCTET STRING (SIZE (0..256))currentIP address of BFD peer.
VmwNsxTDataCenterPolicyEdgeVMNameTypeOCTET STRING (SIZE (0..256))currentString containing Edge VM name corresponding to Policy/MP intent vSphere deployment configuration.
VmwNsxTDataCenterPrefixesCountMaxTypeOCTET STRING (SIZE (0..256))currentMaximum value of prefix count of BGP neighbor.
VmwNsxTDataCenterPrefixesCountThresholdTypeOCTET STRING (SIZE (0..256))currentThreshold Value of prefix count of BGP neighbor.
VmwNsxTDataCenterPreviousGatewayStateTypeOCTET STRING (SIZE (0..256))currentThe previous gateway state. The value could be 0, 1 or 2 where 0 is down, 1 is standby and 2 is active
VmwNsxTDataCenterPreviousServiceStateTypeOCTET STRING (SIZE (0..256))currentThe previous service state. The value could be start/stop/restart/crashed.
VmwNsxTDataCenterProtocolNameTypeOCTET STRING (SIZE (0..256))currentString containing network protocol.
VmwNsxTDataCenterQueueNameTypeOCTET STRING (SIZE (0..256))currentThe name of the queue used to synchronize data between two sites.
VmwNsxTDataCenterQueueSizeThresholdTypeOCTET STRING (SIZE (0..256))currentMaximum threshold value of reported queue size.
VmwNsxTDataCenterQueueSizeTypeOCTET STRING (SIZE (0..256))currentThe occupancy size of queue used to synchronize data between two sites.
VmwNsxTDataCenterRemoteApplianceAddressTypeOCTET STRING (SIZE (0..256))currentThe remote NSX appliance's IP address. The value is an IPv4 address.
VmwNsxTDataCenterRemoteManagerNodeIdTypeOCTET STRING (SIZE (0..256))currentThe remote Manager node UUID.
VmwNsxTDataCenterRemoteSiteIdTypeOCTET STRING (SIZE (0..256))currentThe identifier for a remote site.
VmwNsxTDataCenterRemoteSiteNameTypeOCTET STRING (SIZE (0..256))currentName of a remote site in federation. For more information on remote sites and an overview of the federation feature, refer to: https://docs.vmware.com/en/VMware-NSX-T-Data-Center/3.0/administration/GUID-D5B6DC79-6733-44…
VmwNsxTDataCenterRouteLimitMaximumTypeOCTET STRING (SIZE (0..256))currentString representing maximum limit for routes.
VmwNsxTDataCenterRouteLimitThresholdTypeOCTET STRING (SIZE (0..256))currentString representing threshold limit for routes.
VmwNsxTDataCenterRxMissesTypeOCTET STRING (SIZE (0..256))currentThe number of packets missed while receiving due to rx ring buffer being full.
VmwNsxTDataCenterRxProcessedTypeOCTET STRING (SIZE (0..256))currentThe number of successful incoming packets while polling for rx buffer full event.
VmwNsxTDataCenterRxRingBufferOverflowPercentageTypeOCTET STRING (SIZE (0..256))currentThe NIC's receive descriptor ring buffer on a NSX Edge or Gateway node has no space left to accomodate new incoming packets and there is a significant drop due to it. The value is a float between 0 to 100 describing the…
VmwNsxTDataCenterServiceDownReasonTypeOCTET STRING (SIZE (0..256))currentReason service is down.
VmwNsxTDataCenterServiceIPTypeOCTET STRING (SIZE (0..256))currentThe IP configured for the service running in an NSX appliance in dotted-decimal format.
VmwNsxTDataCenterServiceNameTypeOCTET STRING (SIZE (0..256))currentThe name of the service running in an NSX appliance.
VmwNsxTDataCenterServiceRouterIdTypeOCTET STRING (SIZE (0..256))currentThe ID of a service-router that is part of a tier0 or tier1 gateway spanning one or more edges
VmwNsxTDataCenterSessionDownReasonTypeOCTET STRING (SIZE (0..256))currentDown reason of the IPsec VPN session.
VmwNsxTDataCenterSeverityTypeINTEGER { emergency(0), alert(1), critical(2), error(3), warning(4), notice(5), informational(6), debug(7) }currentThe severity of the NSX Data Center event. Currently only the critical(2), error(3), warning(4) and informational(6) levels are used, but the other levels may be used in future releases.
VmwNsxTDataCenterSidCountTypeOCTET STRING (SIZE (0..256))currentNumber of security IDs inside one group.
VmwNsxTDataCenterSiteIdTypeOCTET STRING (SIZE (0..256))currentThe identifier for a local site.
VmwNsxTDataCenterSiteNameTypeOCTET STRING (SIZE (0..256))currentName of a local site in federation. For more information on local sites and an overview of the federation feature, refer to: https://docs.vmware.com/en/VMware-NSX-T-Data-Center/3.0/administration/GUID-D5B6DC79-6733-44A7…
VmwNsxTDataCenterSNATIPAddressTypeOCTET STRING (SIZE (0..256))currentThe SNAT IP address which ran out of port threshold.
VmwNsxTDataCenterSrIdTypeOCTET STRING (SIZE (0..256))currentService Router UUID.
VmwNsxTDataCenterStackAliasTypeOCTET STRING (SIZE (0..256))currentStack name specified for given vmknic.
VmwNsxTDataCenterStaticAddressTypeOCTET STRING (SIZE (0..256))currentA Static IP address.
VmwNsxTDataCenterSubsequentAddressFamilyTypeOCTET STRING (SIZE (0..256))currentString representing subsequent address family (Unicast or Multicast).
VmwNsxTDataCenterSyncIssueReasonTypeOCTET STRING (SIZE (0..256))currentA reason for data synchronization issue.
VmwNsxTDataCenterSystemResourceUsageTypeOCTET STRING (SIZE (0..256))currentThe CPU, memory, or disk usage percentage of an NSX appliance. The value is an integer between 0 and 100.
VmwNsxTDataCenterSystemUsageThresholdTypeOCTET STRING (SIZE (0..256))currentThe configured threshold value for the CPU, memory, or disk usage percentage of an NSX appliance. The value is an integer between 0 and 100.
VmwNsxTDataCenterTimeoutInMinutesTypeOCTET STRING (SIZE (0..256))currentTimeout value in minutes.
VmwNsxTDataCenterTNCountTypeOCTET STRING (SIZE (0..256))currentNumber of Transport Nodes inside one group.
VmwNsxTDataCenterToGMPathTypeOCTET STRING (SIZE (0..256))currentPolicy path of the Global Manager.
VmwNsxTDataCenterTransportNodeAddressTypeOCTET STRING (SIZE (0..256))currentThe IP address of a NSX Transport node.
VmwNsxTDataCenterTransportNodeId2TypeOCTET STRING (SIZE (0..256))currentThe Transport node UUID.
VmwNsxTDataCenterTransportNodeIdTypeOCTET STRING (SIZE (0..256))currentThe Transport node UUID.
VmwNsxTDataCenterTransportNodeNameTypeOCTET STRING (SIZE (0..256))currentThe display name of a NSX Transport node.
VmwNsxTDataCenterTunnelDownReasonTypeOCTET STRING (SIZE (0..256))currentDown reason of the IPsec VPN tunnel.
VmwNsxTDataCenterTxMissesTypeOCTET STRING (SIZE (0..256))currentThe number of packets missed while transmitting due to tx ring buffer being full.
VmwNsxTDataCenterTxProcessedTypeOCTET STRING (SIZE (0..256))currentThe number of successful outgoing packets while polling for tx buffer full event.
VmwNsxTDataCenterTxRingBufferOverflowPercentageTypeOCTET STRING (SIZE (0..256))currentThe NIC's transmit descriptor ring buffer on a NSX Edge or Gateway node has no space left to accomodate new outgoing packets and there is a significant drop due to it. The value is a float between 0 to 100 describing th…
VmwNsxTDataCenterUsernameTypeOCTET STRING (SIZE (0..256))currentThe name of a user in an NSX appliance.
VmwNsxTDataCentervCenterClusterIdTypeOCTET STRING (SIZE (0..256))currentCluster identifier in the Virtual Center.
VmwNsxTDataCenterVerticalNameTypeOCTET STRING (SIZE (0..256))currentName of OPS vertical on DPU.
VmwNsxTDataCenterVifCountTypeOCTET STRING (SIZE (0..256))currentNumber of VIFs inside one group.
VmwNsxTDataCenterVMCountTypeOCTET STRING (SIZE (0..256))currentNumber of VMs inside one group.
VmwNsxTDataCenterVMMorefIdTypeOCTET STRING (SIZE (0..256))currentString containing Edge VM moref details corresponding to Policy/MP intent vSphere deployment configuration.
VmwNsxTDataCenterVtepFaultReasonTypeOCTET STRING (SIZE (0..256))currentThe VTEP fault reason.
VmwNsxTDataCenterVtepNameTypeOCTET STRING (SIZE (0..256))currentThe ESXi VTEP name.