MIB Viewer

WEBMON-EDGE-MATRIX-MIB

919 objects
WebMon Edge-Matrix MIB.
Imported Objects
SNMPv2-CONFNOTIFICATION-GROUP OBJECT-GROUP
SNMPv2-SMIenterprises MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-IDENTITY OBJECT-TYPE
SNMPv2-TCTEXTUAL-CONVENTION
OIDNameAccessStatusDescription
1.3.6.1.4.1.994Nodedantel
1.3.6.1.4.1.994.3NodedantelProducts
1.3.6.1.4.1.994.3.4IdentitywebMoncurrentThe parent node representing the WebMon device.
1.3.6.1.4.1.994.3.4.3IdentitymoduleIdentityWebMon Edge-Matrix MIB.
1.3.6.1.4.1.994.3.4.4GroupnotificationGroupcurrentGroup containing all the notification types.
1.3.6.1.4.1.994.3.4.5GroupobjectGroupcurrentGroup containing all the objects.
1.3.6.1.4.1.994.3.4.6IdentitytrapscurrentCategory containing all the traps. Each trap has sibling data nodes that contain the data associated with the most recently sent trap of that particular type. …
1.3.6.1.4.1.994.3.4.6.1IdentityanalogInputscurrentSubtree containing trap and associated data for analog inputs. Analog inputs measure a value. The input always has a live reading, but traps are only sent on e…
1.3.6.1.4.1.994.3.4.6.1.1NotificationanalogEventTrapcurrentNotification sent upon an analog input reading crossing a threshold.
1.3.6.1.4.1.994.3.4.6.1.2ScalaranalogInputDescriptionread-onlycurrentDescription of the analog input.
1.3.6.1.4.1.994.3.4.6.1.3ScalaranalogLiveLevelread-onlycurrentThe level associated with the analogLiveReading for this input.
1.3.6.1.4.1.994.3.4.6.1.5ScalaranalogLiveReadingread-onlycurrentThe reading from the analog input described by analogInputDescription at the time the trap was sent. It is in the units described in analogUnitsOfMeasurement.
1.3.6.1.4.1.994.3.4.6.1.6ScalaranalogUnitsOfMeasurementread-onlycurrentThe units of measurement associated with the analogLiveReading.
1.3.6.1.4.1.994.3.4.6.1.7ScalaranalogLiveStateread-onlycurrentThe state associated with analogLiveReading.
1.3.6.1.4.1.994.3.4.6.1.8ScalaranalogLiveStateDescriptionread-onlycurrentThe description of the range in which the analogLiveReading is.
1.3.6.1.4.1.994.3.4.6.1.9ScalaranalogAlarmStateread-onlycurrentIf true this field indicates the alarmed state. If false this field indicates the not alarmed state.
1.3.6.1.4.1.994.3.4.6.1.101ScalaranalogSourceDescriptionnot-accessiblecurrentDescription of the event source.
1.3.6.1.4.1.994.3.4.6.1.102ScalaranalogSourceIndexnot-accessiblecurrentIndex of the event source.
1.3.6.1.4.1.994.3.4.6.2IdentitydigitalInputscurrentSubtree containing trap and associated data for digital inputs. Digital inputs monitor a binary state. The input is always in one of two states. Traps are sent…
1.3.6.1.4.1.994.3.4.6.2.1NotificationdigitalEventTrapcurrentNotification sent upon change of state on a digital input.
1.3.6.1.4.1.994.3.4.6.2.2ScalardigitalInputDescriptionread-onlycurrentDescription of the digital input.
1.3.6.1.4.1.994.3.4.6.2.3ScalardigitalLiveLevelread-onlycurrentThe level associated with digitalLiveState for this input.
1.3.6.1.4.1.994.3.4.6.2.4ScalardigitalLiveStateread-onlycurrentThe state of the digital input described by digitalInputDescription at the time the trap was sent.
1.3.6.1.4.1.994.3.4.6.2.5ScalardigitalLiveStateDescriptionread-onlycurrentThe description of the digitalLiveState.
1.3.6.1.4.1.994.3.4.6.2.6ScalardigitalAlarmStateread-onlycurrentIf true this field indicates the alarmed state. If false this field indicates the not alarmed state.
1.3.6.1.4.1.994.3.4.6.2.101ScalardigitalSourceDescriptionnot-accessiblecurrentDescription of the event source.
1.3.6.1.4.1.994.3.4.6.2.102ScalardigitalSourceIndexnot-accessiblecurrentIndex of the event source.
1.3.6.1.4.1.994.3.4.6.3IdentityremoteDevicescurrentSubtree containing trap and associated data for monitored remote devices. Remote devices are monitored for network connectivity. The device's live state is alw…
1.3.6.1.4.1.994.3.4.6.3.1NotificationremoteDeviceEventTrapcurrentNotification sent upon change of state of a remote device.
1.3.6.1.4.1.994.3.4.6.3.2ScalarremoteDeviceDescriptionread-onlycurrentDescription of the remote device.
1.3.6.1.4.1.994.3.4.6.3.3ScalarremoteDeviceLiveLevelread-onlycurrentThe level associated with remoteDeviceLiveState.
1.3.6.1.4.1.994.3.4.6.3.4ScalarremoteDeviceLiveStateread-onlycurrentThe state of the remote device described by remoteDeviceDescription at the time the trap was sent. Online indicates connected, offline indicates not connected.
1.3.6.1.4.1.994.3.4.6.3.5ScalarremoteDeviceAlarmStateread-onlycurrentIf true this field indicates the alarmed state. If false this field indicates the not alarmed state.
1.3.6.1.4.1.994.3.4.6.3.101ScalarremoteDeviceSourceDescriptionnot-accessiblecurrentDescription of the event source.
1.3.6.1.4.1.994.3.4.6.3.102ScalarremoteDeviceSourceIndexnot-accessiblecurrentIndex of the event source.
1.3.6.1.4.1.994.3.4.6.4IdentityfaultscurrentSubtree containing trap and associated data for faults. Faults are conditions internal to the WebMon. The only data associated with this trap is a string that …
1.3.6.1.4.1.994.3.4.6.4.1NotificationfaultTrapcurrentNotification sent when a fault is encountered.
1.3.6.1.4.1.994.3.4.6.4.2ScalarfaultDescriptionread-onlycurrentDescription of the condition at the WebMon.
1.3.6.1.4.1.994.3.4.6.4.3ScalarfaultLiveLevelread-onlycurrentThe level associated with faultStateDescription.
1.3.6.1.4.1.994.3.4.6.4.4ScalarfaultStateDescriptionread-onlycurrentThe description of the state of this fault.
1.3.6.1.4.1.994.3.4.6.4.5ScalarfaultAlarmStateread-onlycurrentIf true this field indicates the alarmed state. If false this field indicates the not alarmed state.
1.3.6.1.4.1.994.3.4.6.4.101ScalarfaultSourceDescriptionnot-accessiblecurrentDescription of the event source.
1.3.6.1.4.1.994.3.4.6.4.102ScalarfaultSourceIndexnot-accessiblecurrentIndex of the event source.
1.3.6.1.4.1.994.3.4.7Nodeconfiguration
1.3.6.1.4.1.994.3.4.7.1NodesystemGeneral
1.3.6.1.4.1.994.3.4.7.1.2ScalarsystemGeneralLocationread-writecurrentLocation on the device.
1.3.6.1.4.1.994.3.4.7.1.3ScalarsystemGeneralDescriptionread-writecurrentDescription of the device.
1.3.6.1.4.1.994.3.4.7.1.14ScalarsystemGeneralIpAddressread-writecurrentIP Address of the device. If changed, the new IP address will only take effect after a reset.
1.3.6.1.4.1.994.3.4.7.1.15ScalarsystemGeneralSubnetMaskread-writecurrentSubnet Mask of the device. If changed, the new IP address will only take effect after a reset.
1.3.6.1.4.1.994.3.4.7.1.16ScalarsystemGeneralGatewayAddressread-writecurrentGateway Address of the device. If changed, the new IP address will only take effect after a reset.
1.3.6.1.4.1.994.3.4.7.1.23ScalarsystemGeneralReadPeriodread-writecurrentThe number of minutes until the WebMon resets itself.
1.3.6.1.4.1.994.3.4.7.1.45ScalarsystemGeneralMeasureStyleread-writecurrentDetermines if units are displayed in English or Metric.
1.3.6.1.4.1.994.3.4.7.1.54ScalarsystemGeneralMacAddressread-onlycurrentThe MAC address of the device.
1.3.6.1.4.1.994.3.4.7.1.70ScalarsystemGeneralProductTyperead-onlycurrentDescribes the type of device.
1.3.6.1.4.1.994.3.4.7.1.73ScalarsystemGeneralIPPortNumread-writecurrentIP port number to use when connecting to the web page (HTTP).
1.3.6.1.4.1.994.3.4.7.1.82ScalarsystemGeneralVersionread-onlycurrentThe version of the running software.
1.3.6.1.4.1.994.3.4.7.1.98ScalarsystemGeneralUseResetTimeread-writecurrentIf enabled, the WebMon will reset periodically.
1.3.6.1.4.1.994.3.4.7.1.147ScalarsystemGeneralEthernetTyperead-writecurrentEthernet duplex type of the device. If changed, the new duplex type will only take effect after a reset.
1.3.6.1.4.1.994.3.4.7.1.148ScalarsystemGeneralEthernetRateread-writecurrentEthernet rate of the device. If changed, the new rate will only take effect after a reset.
1.3.6.1.4.1.994.3.4.7.1.149ScalarsystemGeneralContactread-writecurrentSNMP contact information.
1.3.6.1.4.1.994.3.4.7.2TablepTrapTargetTablenot-accessiblecurrentTable for configuration of TrapTarget
1.3.6.1.4.1.994.3.4.7.2.1RowpTrapTargetEntrynot-accessiblecurrentEntry for configuration table of TrapTarget
1.3.6.1.4.1.994.3.4.7.2.1.3ColumnpTrapTargetDescriptionread-writecurrentDescription of the trap target.
1.3.6.1.4.1.994.3.4.7.2.1.10ColumnpTrapTargetConfiguredread-writecurrentDetermines if traps will be sent to trap target with given IP address.
1.3.6.1.4.1.994.3.4.7.2.1.14ColumnpTrapTargetIpAddressread-writecurrentSNMP traps are sent to this IP address.
1.3.6.1.4.1.994.3.4.7.2.1.42ColumnpTrapTargetSnmpVersionread-writecurrentIndicates the version of SNMP trap to use.
1.3.6.1.4.1.994.3.4.7.2.1.73ColumnpTrapTargetIPPortNumread-writecurrentSNMP traps are sent to this network port.
1.3.6.1.4.1.994.3.4.7.2.1.78ColumnpTrapTargetBackupIPAddressread-writecurrentUsed only when dialing out as backup.
1.3.6.1.4.1.994.3.4.7.2.1.125ColumnpTrapTargetUseDialoutread-writecurrentDetermines if traps will be sent only when dialed out.
1.3.6.1.4.1.994.3.4.7.2.1.126ColumnpTrapTargetDialoutTargetread-writecurrentDetermines which target to dial out to when sending traps.
1.3.6.1.4.1.994.3.4.7.2.1.140ColumnpTrapTargetAuthKeyread-writecurrent
1.3.6.1.4.1.994.3.4.7.2.1.141ColumnpTrapTargetPrivKeyread-writecurrent
1.3.6.1.4.1.994.3.4.7.2.1.142ColumnpTrapTargetSNMPAccessread-writecurrent
1.3.6.1.4.1.994.3.4.7.2.1.143ColumnpTrapTargetEngineIDread-writecurrent
1.3.6.1.4.1.994.3.4.7.2.1.999ColumnpTrapTargetIndexread-onlycurrentIndex.
1.3.6.1.4.1.994.3.4.7.3TablepEmailTablenot-accessiblecurrentTable for configuration of Email
1.3.6.1.4.1.994.3.4.7.3.1RowpEmailEntrynot-accessiblecurrentEntry for configuration table of Email
1.3.6.1.4.1.994.3.4.7.3.1.1ColumnpEmailAddressread-writecurrentEmail events will be sent to this address.
1.3.6.1.4.1.994.3.4.7.3.1.3ColumnpEmailDescriptionread-writecurrentDescription of the Email target.
1.3.6.1.4.1.994.3.4.7.3.1.10ColumnpEmailConfiguredread-writecurrentIf set to true, email events will be sent to given address. If set to false, email will not be sent.
1.3.6.1.4.1.994.3.4.7.3.1.999ColumnpEmailIndexread-onlycurrentIndex.
1.3.6.1.4.1.994.3.4.7.5TablepRemoteSensorTablenot-accessiblecurrentTable for configuration of RemoteSensor
1.3.6.1.4.1.994.3.4.7.5.1RowpRemoteSensorEntrynot-accessiblecurrentEntry for configuration table of RemoteSensor
1.3.6.1.4.1.994.3.4.7.5.1.3ColumnpRemoteSensorDescriptionread-writecurrentDescription of the Analog device.
1.3.6.1.4.1.994.3.4.7.5.1.4ColumnpRemoteSensorDesc0read-writecurrentThe description for values between threshold 0 and threshold 1.
1.3.6.1.4.1.994.3.4.7.5.1.5ColumnpRemoteSensorDesc1read-writecurrentThe description for values between threshold 1 and threshold 2.
1.3.6.1.4.1.994.3.4.7.5.1.6ColumnpRemoteSensorDesc2read-writecurrentThe description for values between threshold 2 and threshold 3.
1.3.6.1.4.1.994.3.4.7.5.1.7ColumnpRemoteSensorDesc3read-writecurrentThe description for values between threshold 3 and threshold 4.
1.3.6.1.4.1.994.3.4.7.5.1.8ColumnpRemoteSensorDesc4read-writecurrentThe description for values between threshold 4 and threshold 5.
1.3.6.1.4.1.994.3.4.7.5.1.9ColumnpRemoteSensorDesc5read-writecurrentDescription for a communications failure to the remote analog device.
1.3.6.1.4.1.994.3.4.7.5.1.10ColumnpRemoteSensorConfiguredread-writecurrentIf set to true analog values will be monitored. If set to false no values will be monitored.
1.3.6.1.4.1.994.3.4.7.5.1.11ColumnpRemoteSensorSendEmailread-writecurrentIf set to true an email event will be set when a threshold is crossed. If set to false no email event will be sent.
1.3.6.1.4.1.994.3.4.7.5.1.12ColumnpRemoteSensorSendSNMPTrapread-writecurrentIf set to true an SNMP trap will be set when a threshold is crossed. If set to false no SNMP trap will be sent.
1.3.6.1.4.1.994.3.4.7.5.1.17ColumnpRemoteSensorLevel0read-writecurrentThe level for values between threshold 0 and threshold 1.
1.3.6.1.4.1.994.3.4.7.5.1.18ColumnpRemoteSensorLevel1read-writecurrentThe level for values between threshold 1 and threshold 2.
1.3.6.1.4.1.994.3.4.7.5.1.19ColumnpRemoteSensorLevel2read-writecurrentThe level for values between threshold 2 and threshold 3.
1.3.6.1.4.1.994.3.4.7.5.1.20ColumnpRemoteSensorLevel3read-writecurrentThe level for values between threshold 3 and threshold 4.
1.3.6.1.4.1.994.3.4.7.5.1.21ColumnpRemoteSensorLevel4read-writecurrentThe level for values between threshold 4 and threshold 5.
1.3.6.1.4.1.994.3.4.7.5.1.22ColumnpRemoteSensorLevel5read-writecurrentLevel of a communications failure to the remote analog device.
1.3.6.1.4.1.994.3.4.7.5.1.28ColumnpRemoteSensorThresh0read-writecurrentThis is the maximum analog value.
1.3.6.1.4.1.994.3.4.7.5.1.29ColumnpRemoteSensorThresh1read-writecurrentThis is the first threshold value.
1.3.6.1.4.1.994.3.4.7.5.1.30ColumnpRemoteSensorThresh2read-writecurrentThis is the second threshold value.
1.3.6.1.4.1.994.3.4.7.5.1.31ColumnpRemoteSensorThresh3read-writecurrentThis is the third threshold value.
1.3.6.1.4.1.994.3.4.7.5.1.32ColumnpRemoteSensorThresh4read-writecurrentThis is the fourth threshold value.
1.3.6.1.4.1.994.3.4.7.5.1.33ColumnpRemoteSensorThresh5read-writecurrentThis is the minimum threshold value.
1.3.6.1.4.1.994.3.4.7.5.1.46ColumnpRemoteSensorUnitsread-writecurrentDescription of the units of measurement.
1.3.6.1.4.1.994.3.4.7.5.1.56ColumnpRemoteSensorPollAddressread-writecurrentThe polling address of the analog device.
1.3.6.1.4.1.994.3.4.7.5.1.64ColumnpRemoteSensorLiveDescriptionread-onlycurrentThe description of the current state of the analog device
1.3.6.1.4.1.994.3.4.7.5.1.65ColumnpRemoteSensorLiveLevelread-onlycurrentThe level of the current state of the analog device.
1.3.6.1.4.1.994.3.4.7.5.1.66ColumnpRemoteSensorLiveRawread-onlycurrentThe current reading from the analog device. This value will always be between the threshold 0 and threshold 5 values.
1.3.6.1.4.1.994.3.4.7.5.1.67ColumnpRemoteSensorLiveTimeread-onlycurrentThe time of the last event.
1.3.6.1.4.1.994.3.4.7.5.1.116ColumnpRemoteSensorTL1SIDread-writecurrent(TL1) System ID associated with this item.
1.3.6.1.4.1.994.3.4.7.5.1.117ColumnpRemoteSensorTL1CONDread-writecurrent(TL1) Condition text associated with this item.
1.3.6.1.4.1.994.3.4.7.5.1.118ColumnpRemoteSensorTL1Eqptread-writecurrent(TL1) EQPT field associated with this item.
1.3.6.1.4.1.994.3.4.7.5.1.119ColumnpRemoteSensorTL1Envread-writecurrent(TL1) Environmental field associated with this item.
1.3.6.1.4.1.994.3.4.7.5.1.120ColumnpRemoteSensorTL1Srveffread-writecurrent(TL1) Service Effecting field associated with this item.
1.3.6.1.4.1.994.3.4.7.5.1.121ColumnpRemoteSensorTL1Locnread-writecurrent(TL1) Location field associated with this item.
1.3.6.1.4.1.994.3.4.7.5.1.122ColumnpRemoteSensorTL1Dirnread-writecurrent(TL1) Direction field associated with this item.
1.3.6.1.4.1.994.3.4.7.5.1.144ColumnpRemoteSensorMODBUSCommandread-writecurrentThe polling command for the analog device.
1.3.6.1.4.1.994.3.4.7.5.1.145ColumnpRemoteSensorStartRegisterread-writecurrentThe MODBUS register for the analog device.
1.3.6.1.4.1.994.3.4.7.5.1.999ColumnpRemoteSensorIndexread-onlycurrentIndex.
1.3.6.1.4.1.994.3.4.7.6TablepOnboardSensorTablenot-accessiblecurrentTable for configuration of OnboardSensor
1.3.6.1.4.1.994.3.4.7.6.1RowpOnboardSensorEntrynot-accessiblecurrentEntry for configuration table of OnboardSensor
1.3.6.1.4.1.994.3.4.7.6.1.3ColumnpOnboardSensorDescriptionread-onlycurrentDescription of the onboard sensor input.
1.3.6.1.4.1.994.3.4.7.6.1.4ColumnpOnboardSensorDesc0read-writecurrentThe description for values between threshold 0 and threshold 1.
1.3.6.1.4.1.994.3.4.7.6.1.5ColumnpOnboardSensorDesc1read-writecurrentThe description for values between threshold 1 and threshold 2.
1.3.6.1.4.1.994.3.4.7.6.1.6ColumnpOnboardSensorDesc2read-writecurrentThe description for values between threshold 2 and threshold 3.
1.3.6.1.4.1.994.3.4.7.6.1.7ColumnpOnboardSensorDesc3read-writecurrentThe description for values between threshold 3 and threshold 4.
1.3.6.1.4.1.994.3.4.7.6.1.8ColumnpOnboardSensorDesc4read-writecurrentThe description for values between threshold 4 and threshold 5.
1.3.6.1.4.1.994.3.4.7.6.1.9ColumnpOnboardSensorDesc5read-writecurrentDescription for a communications failure to the sensor.
1.3.6.1.4.1.994.3.4.7.6.1.10ColumnpOnboardSensorConfiguredread-writecurrentIf set to true, the sensor input will be usable. If set to false the sensor input will be ignored.
1.3.6.1.4.1.994.3.4.7.6.1.11ColumnpOnboardSensorSendEmailread-writecurrentIf set to true an email event will be set when a threshold is crossed. If set to false no email event will be sent.
1.3.6.1.4.1.994.3.4.7.6.1.12ColumnpOnboardSensorSendSNMPTrapread-writecurrentIf set to true an SNMP trap will be set when a threshold is crossed. If set to false no SNMP trap will be sent.
1.3.6.1.4.1.994.3.4.7.6.1.17ColumnpOnboardSensorLevel0read-writecurrentThe level for values between threshold 0 and threshold 1.
1.3.6.1.4.1.994.3.4.7.6.1.18ColumnpOnboardSensorLevel1read-writecurrentThe level for values between threshold 1 and threshold 2.
1.3.6.1.4.1.994.3.4.7.6.1.19ColumnpOnboardSensorLevel2read-writecurrentThe level for values between threshold 2 and threshold 3.
1.3.6.1.4.1.994.3.4.7.6.1.20ColumnpOnboardSensorLevel3read-writecurrentThe level for values between threshold 3 and threshold 4.
1.3.6.1.4.1.994.3.4.7.6.1.21ColumnpOnboardSensorLevel4read-writecurrentThe level for values between threshold 4 and threshold 5.
1.3.6.1.4.1.994.3.4.7.6.1.22ColumnpOnboardSensorLevel5read-writecurrentLevel of a communications failure to the sensor.
1.3.6.1.4.1.994.3.4.7.6.1.28ColumnpOnboardSensorThresh0read-onlycurrentThis is the minimun analog value.
1.3.6.1.4.1.994.3.4.7.6.1.29ColumnpOnboardSensorThresh1read-writecurrentThis is the first threshold value.
1.3.6.1.4.1.994.3.4.7.6.1.30ColumnpOnboardSensorThresh2read-writecurrentThis is the second threshold value.
1.3.6.1.4.1.994.3.4.7.6.1.31ColumnpOnboardSensorThresh3read-writecurrentThis is the third threshold value.
1.3.6.1.4.1.994.3.4.7.6.1.32ColumnpOnboardSensorThresh4read-writecurrentThis is the fourth threshold value.
1.3.6.1.4.1.994.3.4.7.6.1.33ColumnpOnboardSensorThresh5read-onlycurrentThis is the maximum threshold value.
1.3.6.1.4.1.994.3.4.7.6.1.46ColumnpOnboardSensorUnitsread-onlycurrentDescription of the units of measurement.
1.3.6.1.4.1.994.3.4.7.6.1.64ColumnpOnboardSensorLiveDescriptionread-onlycurrentThe description of the current state of the onboard sensor
1.3.6.1.4.1.994.3.4.7.6.1.65ColumnpOnboardSensorLiveLevelread-onlycurrentThe level of the current state of the onboard sensor.
1.3.6.1.4.1.994.3.4.7.6.1.66ColumnpOnboardSensorLiveRawread-onlycurrentThe current reading from the onboard sensor. This value will always be between the threshold 0 and threshold 5 values.
1.3.6.1.4.1.994.3.4.7.6.1.67ColumnpOnboardSensorLiveTimeread-onlycurrentThe time of the last event.
1.3.6.1.4.1.994.3.4.7.6.1.116ColumnpOnboardSensorTL1SIDread-writecurrent(TL1) System ID associated with this item.
1.3.6.1.4.1.994.3.4.7.6.1.117ColumnpOnboardSensorTL1CONDread-writecurrent(TL1) Condition text associated with this item.
1.3.6.1.4.1.994.3.4.7.6.1.118ColumnpOnboardSensorTL1Eqptread-writecurrent(TL1) EQPT field associated with this item.
1.3.6.1.4.1.994.3.4.7.6.1.119ColumnpOnboardSensorTL1Envread-writecurrent(TL1) Environmental field associated with this item.
1.3.6.1.4.1.994.3.4.7.6.1.120ColumnpOnboardSensorTL1Srveffread-writecurrent(TL1) Service Effecting field associated with this item.
1.3.6.1.4.1.994.3.4.7.6.1.121ColumnpOnboardSensorTL1Locnread-writecurrent(TL1) Location field associated with this item.
1.3.6.1.4.1.994.3.4.7.6.1.122ColumnpOnboardSensorTL1Dirnread-writecurrent(TL1) Direction field associated with this item.
1.3.6.1.4.1.994.3.4.7.6.1.131ColumnpOnboardSensorSensorTyperead-onlycurrentThe type of sensor.
1.3.6.1.4.1.994.3.4.7.6.1.999ColumnpOnboardSensorIndexread-onlycurrentIndex.
1.3.6.1.4.1.994.3.4.7.7TablepNetDevicesTablenot-accessiblecurrentTable for configuration of NetDevices
1.3.6.1.4.1.994.3.4.7.7.1RowpNetDevicesEntrynot-accessiblecurrentEntry for configuration table of NetDevices
1.3.6.1.4.1.994.3.4.7.7.1.3ColumnpNetDevicesDescriptionread-writecurrentDescription of the network device.
1.3.6.1.4.1.994.3.4.7.7.1.4ColumnpNetDevicesDesc0read-writecurrentText description of online state.
1.3.6.1.4.1.994.3.4.7.7.1.5ColumnpNetDevicesDesc1read-writecurrentText description of offline state.
1.3.6.1.4.1.994.3.4.7.7.1.10ColumnpNetDevicesConfiguredread-writecurrentIf set to true, net device will be pinged, If set to false, no action will be taken.
1.3.6.1.4.1.994.3.4.7.7.1.11ColumnpNetDevicesSendEmailread-writecurrentIf set to true, an email will be sent when a change of state is detected. If set to false, no email will be sent.
1.3.6.1.4.1.994.3.4.7.7.1.12ColumnpNetDevicesSendSNMPTrapread-writecurrentIf set to true, an SNMP trap will be sent when a change of state is detected. If set to false, no SNMP trap will be sent.
1.3.6.1.4.1.994.3.4.7.7.1.14ColumnpNetDevicesIpAddressread-writecurrentThe IP address of the net device to ping.
1.3.6.1.4.1.994.3.4.7.7.1.17ColumnpNetDevicesLevel0read-writecurrentAlarm level associated with the online state.
1.3.6.1.4.1.994.3.4.7.7.1.18ColumnpNetDevicesLevel1read-writecurrentAlarm level associated with the offline state.
1.3.6.1.4.1.994.3.4.7.7.1.64ColumnpNetDevicesLiveDescriptionread-onlycurrentThe description of the current state of the net device
1.3.6.1.4.1.994.3.4.7.7.1.65ColumnpNetDevicesLiveLevelread-onlycurrentThe level of the current state of the net device.
1.3.6.1.4.1.994.3.4.7.7.1.66ColumnpNetDevicesLiveRawread-onlycurrentThe current reading from the net device. This value will always be between the threshold 0 and threshold 5 values.
1.3.6.1.4.1.994.3.4.7.7.1.67ColumnpNetDevicesLiveTimeread-onlycurrentThe time of the last event.
1.3.6.1.4.1.994.3.4.7.7.1.116ColumnpNetDevicesTL1SIDread-writecurrent(TL1) System ID associated with this item.
1.3.6.1.4.1.994.3.4.7.7.1.117ColumnpNetDevicesTL1CONDread-writecurrent(TL1) Condition text associated with this item.
1.3.6.1.4.1.994.3.4.7.7.1.118ColumnpNetDevicesTL1Eqptread-writecurrent(TL1) EQPT field associated with this item.
1.3.6.1.4.1.994.3.4.7.7.1.119ColumnpNetDevicesTL1Envread-writecurrent(TL1) Environmental field associated with this item.
1.3.6.1.4.1.994.3.4.7.7.1.120ColumnpNetDevicesTL1Srveffread-writecurrent(TL1) Service Effecting field associated with this item.
1.3.6.1.4.1.994.3.4.7.7.1.121ColumnpNetDevicesTL1Locnread-writecurrent(TL1) Location field associated with this item.
1.3.6.1.4.1.994.3.4.7.7.1.122ColumnpNetDevicesTL1Dirnread-writecurrent(TL1) Direction field associated with this item.
1.3.6.1.4.1.994.3.4.7.7.1.999ColumnpNetDevicesIndexread-onlycurrentIndex.
1.3.6.1.4.1.994.3.4.7.9TablepAccountsTablenot-accessiblecurrentTable for configuration of Accounts
1.3.6.1.4.1.994.3.4.7.9.1RowpAccountsEntrynot-accessiblecurrentEntry for configuration table of Accounts
1.3.6.1.4.1.994.3.4.7.9.1.10ColumnpAccountsConfiguredread-writecurrentIf set to true, this account can be used to login.
1.3.6.1.4.1.994.3.4.7.9.1.25ColumnpAccountsNameread-writecurrentName associated with this account.
1.3.6.1.4.1.994.3.4.7.9.1.27ColumnpAccountsEncPasswordread-writecurrentPassword for this account. When reading, an encrypted version of password will be displayed. When writing, use plain text.
1.3.6.1.4.1.994.3.4.7.9.1.55ColumnpAccountsUserLevelread-writecurrentThe user level for this account. One of the following masks from each group are used: No FTP access 0x0000 0 FTP read-only 0x0001 1 FTP Full access 0x0003 3 No…
1.3.6.1.4.1.994.3.4.7.9.1.77ColumnpAccountsUnsecuredread-writecurrentAllow secured configuration for SNMP through this account.
1.3.6.1.4.1.994.3.4.7.9.1.140ColumnpAccountsAuthKeyread-writecurrent
1.3.6.1.4.1.994.3.4.7.9.1.141ColumnpAccountsPrivKeyread-writecurrent
1.3.6.1.4.1.994.3.4.7.9.1.142ColumnpAccountsSNMPAccessread-writecurrent
1.3.6.1.4.1.994.3.4.7.9.1.999ColumnpAccountsIndexread-onlycurrentIndex.
1.3.6.1.4.1.994.3.4.7.10Nodecamera
1.3.6.1.4.1.994.3.4.7.10.10ScalarcameraConfiguredread-writecurrentIf set to true, camera view will be used in main webpage. If set to false, camera view will not be used.
1.3.6.1.4.1.994.3.4.7.10.14ScalarcameraIpAddressread-writecurrentIP address of the camera.
1.3.6.1.4.1.994.3.4.7.10.43ScalarcameraCameraStyleread-writecurrentType of camera used.
1.3.6.1.4.1.994.3.4.7.12NodesnmpGeneral
1.3.6.1.4.1.994.3.4.7.12.10ScalarsnmpGeneralConfiguredread-writecurrentResend standing alarms at a given interval
1.3.6.1.4.1.994.3.4.7.12.23ScalarsnmpGeneralReadPeriodread-writecurrentPeriod in minutes between resend of standing alarms
1.3.6.1.4.1.994.3.4.7.12.39ScalarsnmpGeneralGetread-writecurrentGet community name for SNMP.
1.3.6.1.4.1.994.3.4.7.12.40ScalarsnmpGeneralSetread-writecurrentSet community name for SNMP.
1.3.6.1.4.1.994.3.4.7.12.41ScalarsnmpGeneralTrapread-writecurrentTrap community name for SNMP.
1.3.6.1.4.1.994.3.4.7.12.73ScalarsnmpGeneralIPPortNumread-writecurrentSNMP configuration is done on this network port.
1.3.6.1.4.1.994.3.4.7.12.143ScalarsnmpGeneralEngineIDread-onlycurrentSNMP v3 engine ID
1.3.6.1.4.1.994.3.4.7.13NodeemailGeneral
1.3.6.1.4.1.994.3.4.7.13.1ScalaremailGeneralAddressread-writecurrentLogin name to use if logging into email server is true.
1.3.6.1.4.1.994.3.4.7.13.10ScalaremailGeneralConfiguredread-writecurrentIf set to true, the device will log onto the email server before sending and email event. If set to false, the device will not log onto email server.
1.3.6.1.4.1.994.3.4.7.13.14ScalaremailGeneralIpAddressread-writecurrentIP address of email server.
1.3.6.1.4.1.994.3.4.7.13.26ScalaremailGeneralPasswordread-writecurrentPassword to use if logging into email server is true.
1.3.6.1.4.1.994.3.4.7.13.73ScalaremailGeneralIPPortNumread-writecurrentPort number address of email server.
1.3.6.1.4.1.994.3.4.7.14TablepSerialTablenot-accessiblecurrentTable for configuration of Serial
1.3.6.1.4.1.994.3.4.7.14.1RowpSerialEntrynot-accessiblecurrentEntry for configuration table of Serial
1.3.6.1.4.1.994.3.4.7.14.1.3ColumnpSerialDescriptionread-onlycurrentDescription of the serial port.
1.3.6.1.4.1.994.3.4.7.14.1.10ColumnpSerialConfiguredread-writecurrentIf set to true, this serial port will be usable. If set to false the port will not be usable.
1.3.6.1.4.1.994.3.4.7.14.1.14ColumnpSerialIpAddressread-writecurrentIP Address of the target device.
1.3.6.1.4.1.994.3.4.7.14.1.23ColumnpSerialReadPeriodread-writecurrentInactivity timeout (in minutes).
1.3.6.1.4.1.994.3.4.7.14.1.57ColumnpSerialBaudRateread-writecurrentBaud rate of the serial port.
1.3.6.1.4.1.994.3.4.7.14.1.58ColumnpSerialDataBitsread-writecurrentNumber of data bit for the serial port.
1.3.6.1.4.1.994.3.4.7.14.1.59ColumnpSerialParityread-writecurrentParity of the serial port.
1.3.6.1.4.1.994.3.4.7.14.1.60ColumnpSerialStopBitsread-writecurrentNumber of stop bits for the serial port.
1.3.6.1.4.1.994.3.4.7.14.1.61ColumnpSerialProtocolread-writecurrentProtocol the serial port is speaking.
1.3.6.1.4.1.994.3.4.7.14.1.62ColumnpSerialSerialRTSread-writecurrentRequest To Send (RTS) setting for the serial port.
1.3.6.1.4.1.994.3.4.7.14.1.63ColumnpSerialSerialCTSread-writecurrentClear To Send (CTS) setting for the serial port.
1.3.6.1.4.1.994.3.4.7.14.1.68ColumnpSerialPresentread-onlycurrentIf set to true, the serial port exists. If set to false the serial port does not exist.
1.3.6.1.4.1.994.3.4.7.14.1.73ColumnpSerialIPPortNumread-writecurrentIP port number of the target device.
1.3.6.1.4.1.994.3.4.7.14.1.76ColumnpSerialPortTyperead-onlycurrentThe type of serial port.
1.3.6.1.4.1.994.3.4.7.14.1.999ColumnpSerialIndexread-onlycurrentIndex.
1.3.6.1.4.1.994.3.4.7.15TablepSelfTestTablenot-accessiblecurrentTable for configuration of SelfTest
1.3.6.1.4.1.994.3.4.7.15.1RowpSelfTestEntrynot-accessiblecurrentEntry for configuration table of SelfTest
1.3.6.1.4.1.994.3.4.7.15.1.3ColumnpSelfTestDescriptionread-writecurrentDescription of the Power On Self Test (POST).
1.3.6.1.4.1.994.3.4.7.15.1.10ColumnpSelfTestConfiguredread-writecurrentIf set to true, this POST has passed. If set to false, it has failed.
1.3.6.1.4.1.994.3.4.7.15.1.999ColumnpSelfTestIndexread-onlycurrentIndex.
1.3.6.1.4.1.994.3.4.7.16TablepInternalFaultsTablenot-accessiblecurrentTable for configuration of InternalFaults
1.3.6.1.4.1.994.3.4.7.16.1RowpInternalFaultsEntrynot-accessiblecurrentEntry for configuration table of InternalFaults
1.3.6.1.4.1.994.3.4.7.16.1.3ColumnpInternalFaultsDescriptionread-onlycurrentDescription of the internal fault.
1.3.6.1.4.1.994.3.4.7.16.1.4ColumnpInternalFaultsDesc0read-onlycurrentText description of the healthy state.
1.3.6.1.4.1.994.3.4.7.16.1.5ColumnpInternalFaultsDesc1read-onlycurrentText description of a non-normal state.
1.3.6.1.4.1.994.3.4.7.16.1.6ColumnpInternalFaultsDesc2read-onlycurrentText description of a non-normal state.
1.3.6.1.4.1.994.3.4.7.16.1.7ColumnpInternalFaultsDesc3read-onlycurrentText description of a non-normal state.
1.3.6.1.4.1.994.3.4.7.16.1.11ColumnpInternalFaultsSendEmailread-writecurrentIf set to true an email event will be set when a change occurs. If set to false no email event will be sent.
1.3.6.1.4.1.994.3.4.7.16.1.12ColumnpInternalFaultsSendSNMPTrapread-writecurrentIf set to true an SNMP trap will be set when a change occurs. If set to false no SNMP trap will be sent.
1.3.6.1.4.1.994.3.4.7.16.1.17ColumnpInternalFaultsLevel0read-writecurrentAlarm level associated with the healthy state.
1.3.6.1.4.1.994.3.4.7.16.1.18ColumnpInternalFaultsLevel1read-writecurrentAlarm level associated with this non-normal state.
1.3.6.1.4.1.994.3.4.7.16.1.19ColumnpInternalFaultsLevel2read-writecurrentAlarm level associated with this non-normal state.
1.3.6.1.4.1.994.3.4.7.16.1.20ColumnpInternalFaultsLevel3read-writecurrentAlarm level associated with this non-normal state.
1.3.6.1.4.1.994.3.4.7.16.1.23ColumnpInternalFaultsReadPeriodread-writecurrentDwell time required in milliseconds.
1.3.6.1.4.1.994.3.4.7.16.1.50ColumnpInternalFaultsIgnoreOffread-writecurrentIf true, no event is generated for a change to the healty state.
1.3.6.1.4.1.994.3.4.7.16.1.64ColumnpInternalFaultsLiveDescriptionread-onlycurrentThe current condition of the internal fault.
1.3.6.1.4.1.994.3.4.7.16.1.65ColumnpInternalFaultsLiveLevelread-onlycurrentThe current level of the internal fault.
1.3.6.1.4.1.994.3.4.7.16.1.67ColumnpInternalFaultsLiveTimeread-onlycurrentThe time of the fault event.
1.3.6.1.4.1.994.3.4.7.16.1.98ColumnpInternalFaultsUseResetTimeread-onlycurrentWhen true the configured dwell time is used internally.
1.3.6.1.4.1.994.3.4.7.16.1.999ColumnpInternalFaultsIndexread-onlycurrentIndex.
1.3.6.1.4.1.994.3.4.7.17TablepSlotInfoTablenot-accessiblecurrentTable for configuration of SlotInfo
1.3.6.1.4.1.994.3.4.7.17.1RowpSlotInfoEntrynot-accessiblecurrentEntry for configuration table of SlotInfo
1.3.6.1.4.1.994.3.4.7.17.1.3ColumnpSlotInfoDescriptionread-onlycurrentDescription of the slot contents.
1.3.6.1.4.1.994.3.4.7.17.1.35ColumnpSlotInfoRecordread-onlycurrentThe number of records for this slot.
1.3.6.1.4.1.994.3.4.7.17.1.68ColumnpSlotInfoPresentread-onlycurrentIf true indicates a card is in the slot. If false indicates that no card is present in the slot.
1.3.6.1.4.1.994.3.4.7.17.1.69ColumnpSlotInfoSlotIdread-onlycurrentIdentifies the type of card in slot.
1.3.6.1.4.1.994.3.4.7.17.1.999ColumnpSlotInfoIndexread-onlycurrentIndex.
1.3.6.1.4.1.994.3.4.7.18TablepSlot1Tablenot-accessiblecurrentTable for configuration of Slot1
1.3.6.1.4.1.994.3.4.7.18.1RowpSlot1Entrynot-accessiblecurrentEntry for configuration table of Slot1
1.3.6.1.4.1.994.3.4.7.18.1.3ColumnpSlot1Descriptionread-writecurrentThis field is used in the following card types: discrete-inputs - Description of the alarm point. discrete-outputs - Description of the control point. serial-p…
1.3.6.1.4.1.994.3.4.7.18.1.4ColumnpSlot1Desc0read-writecurrentThis field is used in the following card types: discrete-inputs - Description of the off state. discrete-outputs - Description when the control point is open. …
1.3.6.1.4.1.994.3.4.7.18.1.5ColumnpSlot1Desc1read-writecurrentThis field is used in the following card types: discrete-inputs - Description of the on state. discrete-outputs - Description when the control point is closed.…
1.3.6.1.4.1.994.3.4.7.18.1.6ColumnpSlot1Desc2read-writecurrentThis field is used in the following card types: onboard-sensors - The description for values between threshold 2 and threshold 3. analog-Inputs - The descripti…
1.3.6.1.4.1.994.3.4.7.18.1.7ColumnpSlot1Desc3read-writecurrentThis field is used in the following card types: onboard-sensors - The description for values between threshold 3 and threshold 4. analog-Inputs - The descripti…
1.3.6.1.4.1.994.3.4.7.18.1.8ColumnpSlot1Desc4read-writecurrentThis field is used in the following card types: onboard-sensors - The description for values between threshold 4 and threshold 5. analog-Inputs - The descripti…
1.3.6.1.4.1.994.3.4.7.18.1.9ColumnpSlot1Desc5read-writecurrentThis field is used in the following card types: analog-Inputs - Description for a communications failure to the sensor. analog-Sensors - Description for a comm…
1.3.6.1.4.1.994.3.4.7.18.1.10ColumnpSlot1Configuredread-writecurrentThis field is used in the following card types: discrete-inputs - If set to true, changes of state will be reported. If set to false, not change of states will…
1.3.6.1.4.1.994.3.4.7.18.1.11ColumnpSlot1SendEmailread-writecurrentThis field is used in the following card types: discrete-inputs - If set to true, an email will be sent on a change of state. If false, no email will be sent. …
1.3.6.1.4.1.994.3.4.7.18.1.12ColumnpSlot1SendSNMPTrapread-writecurrentThis field is used in the following card types: discrete-inputs - If set to true, an SNMP trap will be sent on a change of state. If false, no SNMP trap will b…
1.3.6.1.4.1.994.3.4.7.18.1.14ColumnpSlot1IpAddressread-writecurrentThis field is used in the following card types: serial-ports - IP Address of the target device.
1.3.6.1.4.1.994.3.4.7.18.1.17ColumnpSlot1Level0read-writecurrentThis field is used in the following card types: discrete-inputs - Level of the off state. discrete-outputs - Level of the control point when open. onboard-sens…
1.3.6.1.4.1.994.3.4.7.18.1.18ColumnpSlot1Level1read-writecurrentThis field is used in the following card types: discrete-inputs - Level of the on state. discrete-outputs - Level of the control point when closed. onboard-sen…
1.3.6.1.4.1.994.3.4.7.18.1.19ColumnpSlot1Level2read-writecurrentThis field is used in the following card types: onboard-sensors - The level for values between threshold 2 and threshold 3. analog-Inputs - The level for value…
1.3.6.1.4.1.994.3.4.7.18.1.20ColumnpSlot1Level3read-writecurrentThis field is used in the following card types: onboard-sensors - The level for values between threshold 3 and threshold 4. analog-Inputs - The level for value…
1.3.6.1.4.1.994.3.4.7.18.1.21ColumnpSlot1Level4read-writecurrentThis field is used in the following card types: onboard-sensors - The level for values between threshold 4 and threshold 5. analog-Inputs - The level for value…
1.3.6.1.4.1.994.3.4.7.18.1.22ColumnpSlot1Level5read-writecurrentThis field is used in the following card types: analog-Inputs - Level of a communications failure to the sensor. analog-Sensors - Level of a communications fai…
1.3.6.1.4.1.994.3.4.7.18.1.23ColumnpSlot1ReadPeriodread-writecurrentThis field is used in the following card types: serial-ports - Inactivity timeout (in minutes).
1.3.6.1.4.1.994.3.4.7.18.1.28ColumnpSlot1Thresh0read-onlycurrentThis field is used in the following card types: onboard-sensors - This is the minimun analog value. analog-Inputs - This is the maximum analog value. analog-Se…
1.3.6.1.4.1.994.3.4.7.18.1.29ColumnpSlot1Thresh1read-writecurrentThis field is used in the following card types: onboard-sensors - This is the first threshold value. analog-Inputs - This is the first threshold value. analog-…
1.3.6.1.4.1.994.3.4.7.18.1.30ColumnpSlot1Thresh2read-writecurrentThis field is used in the following card types: onboard-sensors - This is the second threshold value. analog-Inputs - This is the second threshold value. analo…
1.3.6.1.4.1.994.3.4.7.18.1.31ColumnpSlot1Thresh3read-writecurrentThis field is used in the following card types: onboard-sensors - This is the third threshold value. analog-Inputs - This is the third threshold value. analog-…
1.3.6.1.4.1.994.3.4.7.18.1.32ColumnpSlot1Thresh4read-writecurrentThis field is used in the following card types: onboard-sensors - This is the fourth threshold value. analog-Inputs - This is the fourth threshold value. analo…
1.3.6.1.4.1.994.3.4.7.18.1.33ColumnpSlot1Thresh5read-onlycurrentThis field is used in the following card types: onboard-sensors - This is the maximum threshold value. analog-Inputs - This is the minimum threshold value. ana…
1.3.6.1.4.1.994.3.4.7.18.1.44ColumnpSlot1ContactStyleread-writecurrentThis field is used in the following card types: discrete-inputs - Determines the type of contact.
1.3.6.1.4.1.994.3.4.7.18.1.46ColumnpSlot1Unitsread-onlycurrentThis field is used in the following card types: onboard-sensors - Description of the units of measurement. analog-Inputs - Description of the units of measurem…
1.3.6.1.4.1.994.3.4.7.18.1.47ColumnpSlot1OutputModeread-writecurrentThis field is used in the following card types: discrete-outputs - Defines the different ways a control point can be activated.
1.3.6.1.4.1.994.3.4.7.18.1.48ColumnpSlot1OutputStateread-writecurrentThis field is used in the following card types: discrete-outputs - A value of 0 will open the control point. A value of 1 will close the control point.
1.3.6.1.4.1.994.3.4.7.18.1.49ColumnpSlot1OutputAutoread-writecurrentThis field is used in the following card types: discrete-outputs - When this control point is opened, this alarm point will change state to the on state.
1.3.6.1.4.1.994.3.4.7.18.1.57ColumnpSlot1BaudRateread-writecurrentThis field is used in the following card types: serial-ports - Baud rate of the serial port.
1.3.6.1.4.1.994.3.4.7.18.1.58ColumnpSlot1DataBitsread-writecurrentThis field is used in the following card types: serial-ports - Number of data bit for the serial port.
1.3.6.1.4.1.994.3.4.7.18.1.59ColumnpSlot1Parityread-writecurrentThis field is used in the following card types: serial-ports - Parity of the serial port.
1.3.6.1.4.1.994.3.4.7.18.1.60ColumnpSlot1StopBitsread-writecurrentThis field is used in the following card types: serial-ports - Number of stop bits for the serial port.
1.3.6.1.4.1.994.3.4.7.18.1.61ColumnpSlot1Protocolread-writecurrentThis field is used in the following card types: serial-ports - Protocol the serial port is speaking.
1.3.6.1.4.1.994.3.4.7.18.1.62ColumnpSlot1SerialRTSread-writecurrentThis field is used in the following card types: serial-ports - Request To Send (RTS) setting for the serial port.
1.3.6.1.4.1.994.3.4.7.18.1.63ColumnpSlot1SerialCTSread-writecurrentThis field is used in the following card types: serial-ports - Clear To Send (CTS) setting for the serial port.
1.3.6.1.4.1.994.3.4.7.18.1.64ColumnpSlot1LiveDescriptionread-onlycurrentThis field is used in the following card types: discrete-inputs - The current description of the alarm state. onboard-sensors - The description of the current …
1.3.6.1.4.1.994.3.4.7.18.1.65ColumnpSlot1LiveLevelread-onlycurrentThis field is used in the following card types: discrete-inputs - The current level of the alarm. onboard-sensors - The level of the current state of the onboa…
1.3.6.1.4.1.994.3.4.7.18.1.66ColumnpSlot1LiveRawread-onlycurrentThis field is used in the following card types: onboard-sensors - The current reading from the onboard sensor. This value will always be between the threshold …
1.3.6.1.4.1.994.3.4.7.18.1.67ColumnpSlot1LiveTimeread-onlycurrentThis field is used in the following card types: discrete-inputs - The time of the last change of state. onboard-sensors - The time of the last event. analog-In…
1.3.6.1.4.1.994.3.4.7.18.1.68ColumnpSlot1Presentread-onlycurrentThis field is used in the following card types: serial-ports - If set to true, the serial port exists. If set to false the serial port does not exist.
1.3.6.1.4.1.994.3.4.7.18.1.71ColumnpSlot1OutputAutoPkgread-writecurrentThis field is used in the following card types: discrete-outputs - When this control point is opened, this is the package that the alarm point is located.
1.3.6.1.4.1.994.3.4.7.18.1.72ColumnpSlot1VoltageRangeread-onlycurrentThis field is used in the following card types: onboard-sensors - The voltage range. analog-Inputs - The voltage range. analog-Sensors - The voltage range.
1.3.6.1.4.1.994.3.4.7.18.1.73ColumnpSlot1IPPortNumread-writecurrentThis field is used in the following card types: serial-ports - IP port number of the target device.
1.3.6.1.4.1.994.3.4.7.18.1.75ColumnpSlot1IOFormatread-onlycurrentThis field is used in the following card types: discrete-inputs - The io format of discrete inputs. discrete-outputs - The io format of discrete outputs. seria…
1.3.6.1.4.1.994.3.4.7.18.1.76ColumnpSlot1PortTyperead-onlycurrentThis field is used in the following card types: serial-ports - The type of serial port.
1.3.6.1.4.1.994.3.4.7.18.1.116ColumnpSlot1TL1SIDread-writecurrentThis field is used in the following card types: discrete-inputs - discrete-outputs - onboard-sensors - analog-Inputs - analog-Sensors -
1.3.6.1.4.1.994.3.4.7.18.1.117ColumnpSlot1TL1CONDread-writecurrentThis field is used in the following card types: discrete-inputs - discrete-outputs - onboard-sensors - analog-Inputs - analog-Sensors -
1.3.6.1.4.1.994.3.4.7.18.1.118ColumnpSlot1TL1Eqptread-writecurrentThis field is used in the following card types: discrete-inputs - onboard-sensors - analog-Inputs - analog-Sensors -
1.3.6.1.4.1.994.3.4.7.18.1.119ColumnpSlot1TL1Envread-writecurrentThis field is used in the following card types: discrete-inputs - onboard-sensors - analog-Inputs - analog-Sensors -
1.3.6.1.4.1.994.3.4.7.18.1.120ColumnpSlot1TL1Srveffread-writecurrentThis field is used in the following card types: discrete-inputs - onboard-sensors - analog-Inputs - analog-Sensors -
1.3.6.1.4.1.994.3.4.7.18.1.121ColumnpSlot1TL1Locnread-writecurrentThis field is used in the following card types: discrete-inputs - onboard-sensors - analog-Inputs - analog-Sensors -
1.3.6.1.4.1.994.3.4.7.18.1.122ColumnpSlot1TL1Dirnread-writecurrentThis field is used in the following card types: discrete-inputs - onboard-sensors - analog-Inputs - analog-Sensors -
1.3.6.1.4.1.994.3.4.7.18.1.131ColumnpSlot1SensorTyperead-onlycurrentThis field is used in the following card types: onboard-sensors - The type of sensor. analog-Inputs - The type of sensor. analog-Sensors - The type of sensor.
1.3.6.1.4.1.994.3.4.7.18.1.999ColumnpSlot1Indexread-onlycurrentIndex.
1.3.6.1.4.1.994.3.4.7.19TablepSlot2Tablenot-accessiblecurrentTable for configuration of Slot2
1.3.6.1.4.1.994.3.4.7.19.1RowpSlot2Entrynot-accessiblecurrentEntry for configuration table of Slot2
1.3.6.1.4.1.994.3.4.7.19.1.3ColumnpSlot2Descriptionread-writecurrentThis field is used in the following card types: discrete-inputs - Description of the alarm point. discrete-outputs - Description of the control point. serial-p…
1.3.6.1.4.1.994.3.4.7.19.1.4ColumnpSlot2Desc0read-writecurrentThis field is used in the following card types: discrete-inputs - Description of the off state. discrete-outputs - Description when the control point is open. …
1.3.6.1.4.1.994.3.4.7.19.1.5ColumnpSlot2Desc1read-writecurrentThis field is used in the following card types: discrete-inputs - Description of the on state. discrete-outputs - Description when the control point is closed.…
1.3.6.1.4.1.994.3.4.7.19.1.6ColumnpSlot2Desc2read-writecurrentThis field is used in the following card types: onboard-sensors - The description for values between threshold 2 and threshold 3. analog-Inputs - The descripti…
1.3.6.1.4.1.994.3.4.7.19.1.7ColumnpSlot2Desc3read-writecurrentThis field is used in the following card types: onboard-sensors - The description for values between threshold 3 and threshold 4. analog-Inputs - The descripti…
1.3.6.1.4.1.994.3.4.7.19.1.8ColumnpSlot2Desc4read-writecurrentThis field is used in the following card types: onboard-sensors - The description for values between threshold 4 and threshold 5. analog-Inputs - The descripti…
1.3.6.1.4.1.994.3.4.7.19.1.9ColumnpSlot2Desc5read-writecurrentThis field is used in the following card types: analog-Inputs - Description for a communications failure to the sensor. analog-Sensors - Description for a comm…
1.3.6.1.4.1.994.3.4.7.19.1.10ColumnpSlot2Configuredread-writecurrentThis field is used in the following card types: discrete-inputs - If set to true, changes of state will be reported. If set to false, not change of states will…
1.3.6.1.4.1.994.3.4.7.19.1.11ColumnpSlot2SendEmailread-writecurrentThis field is used in the following card types: discrete-inputs - If set to true, an email will be sent on a change of state. If false, no email will be sent. …
1.3.6.1.4.1.994.3.4.7.19.1.12ColumnpSlot2SendSNMPTrapread-writecurrentThis field is used in the following card types: discrete-inputs - If set to true, an SNMP trap will be sent on a change of state. If false, no SNMP trap will b…
1.3.6.1.4.1.994.3.4.7.19.1.14ColumnpSlot2IpAddressread-writecurrentThis field is used in the following card types: serial-ports - IP Address of the target device.
1.3.6.1.4.1.994.3.4.7.19.1.17ColumnpSlot2Level0read-writecurrentThis field is used in the following card types: discrete-inputs - Level of the off state. discrete-outputs - Level of the control point when open. onboard-sens…
1.3.6.1.4.1.994.3.4.7.19.1.18ColumnpSlot2Level1read-writecurrentThis field is used in the following card types: discrete-inputs - Level of the on state. discrete-outputs - Level of the control point when closed. onboard-sen…
1.3.6.1.4.1.994.3.4.7.19.1.19ColumnpSlot2Level2read-writecurrentThis field is used in the following card types: onboard-sensors - The level for values between threshold 2 and threshold 3. analog-Inputs - The level for value…
1.3.6.1.4.1.994.3.4.7.19.1.20ColumnpSlot2Level3read-writecurrentThis field is used in the following card types: onboard-sensors - The level for values between threshold 3 and threshold 4. analog-Inputs - The level for value…
1.3.6.1.4.1.994.3.4.7.19.1.21ColumnpSlot2Level4read-writecurrentThis field is used in the following card types: onboard-sensors - The level for values between threshold 4 and threshold 5. analog-Inputs - The level for value…
1.3.6.1.4.1.994.3.4.7.19.1.22ColumnpSlot2Level5read-writecurrentThis field is used in the following card types: analog-Inputs - Level of a communications failure to the sensor. analog-Sensors - Level of a communications fai…
1.3.6.1.4.1.994.3.4.7.19.1.23ColumnpSlot2ReadPeriodread-writecurrentThis field is used in the following card types: serial-ports - Inactivity timeout (in minutes).
1.3.6.1.4.1.994.3.4.7.19.1.28ColumnpSlot2Thresh0read-onlycurrentThis field is used in the following card types: onboard-sensors - This is the minimun analog value. analog-Inputs - This is the maximum analog value. analog-Se…
1.3.6.1.4.1.994.3.4.7.19.1.29ColumnpSlot2Thresh1read-writecurrentThis field is used in the following card types: onboard-sensors - This is the first threshold value. analog-Inputs - This is the first threshold value. analog-…
1.3.6.1.4.1.994.3.4.7.19.1.30ColumnpSlot2Thresh2read-writecurrentThis field is used in the following card types: onboard-sensors - This is the second threshold value. analog-Inputs - This is the second threshold value. analo…
1.3.6.1.4.1.994.3.4.7.19.1.31ColumnpSlot2Thresh3read-writecurrentThis field is used in the following card types: onboard-sensors - This is the third threshold value. analog-Inputs - This is the third threshold value. analog-…
1.3.6.1.4.1.994.3.4.7.19.1.32ColumnpSlot2Thresh4read-writecurrentThis field is used in the following card types: onboard-sensors - This is the fourth threshold value. analog-Inputs - This is the fourth threshold value. analo…
1.3.6.1.4.1.994.3.4.7.19.1.33ColumnpSlot2Thresh5read-onlycurrentThis field is used in the following card types: onboard-sensors - This is the maximum threshold value. analog-Inputs - This is the minimum threshold value. ana…
1.3.6.1.4.1.994.3.4.7.19.1.44ColumnpSlot2ContactStyleread-writecurrentThis field is used in the following card types: discrete-inputs - Determines the type of contact.
1.3.6.1.4.1.994.3.4.7.19.1.46ColumnpSlot2Unitsread-onlycurrentThis field is used in the following card types: onboard-sensors - Description of the units of measurement. analog-Inputs - Description of the units of measurem…
1.3.6.1.4.1.994.3.4.7.19.1.47ColumnpSlot2OutputModeread-writecurrentThis field is used in the following card types: discrete-outputs - Defines the different ways a control point can be activated.
1.3.6.1.4.1.994.3.4.7.19.1.48ColumnpSlot2OutputStateread-writecurrentThis field is used in the following card types: discrete-outputs - A value of 0 will open the control point. A value of 1 will close the control point.
1.3.6.1.4.1.994.3.4.7.19.1.49ColumnpSlot2OutputAutoread-writecurrentThis field is used in the following card types: discrete-outputs - When this control point is opened, this alarm point will change state to the on state.
1.3.6.1.4.1.994.3.4.7.19.1.57ColumnpSlot2BaudRateread-writecurrentThis field is used in the following card types: serial-ports - Baud rate of the serial port.
1.3.6.1.4.1.994.3.4.7.19.1.58ColumnpSlot2DataBitsread-writecurrentThis field is used in the following card types: serial-ports - Number of data bit for the serial port.
1.3.6.1.4.1.994.3.4.7.19.1.59ColumnpSlot2Parityread-writecurrentThis field is used in the following card types: serial-ports - Parity of the serial port.
1.3.6.1.4.1.994.3.4.7.19.1.60ColumnpSlot2StopBitsread-writecurrentThis field is used in the following card types: serial-ports - Number of stop bits for the serial port.
1.3.6.1.4.1.994.3.4.7.19.1.61ColumnpSlot2Protocolread-writecurrentThis field is used in the following card types: serial-ports - Protocol the serial port is speaking.
1.3.6.1.4.1.994.3.4.7.19.1.62ColumnpSlot2SerialRTSread-writecurrentThis field is used in the following card types: serial-ports - Request To Send (RTS) setting for the serial port.
1.3.6.1.4.1.994.3.4.7.19.1.63ColumnpSlot2SerialCTSread-writecurrentThis field is used in the following card types: serial-ports - Clear To Send (CTS) setting for the serial port.
1.3.6.1.4.1.994.3.4.7.19.1.64ColumnpSlot2LiveDescriptionread-onlycurrentThis field is used in the following card types: discrete-inputs - The current description of the alarm state. onboard-sensors - The description of the current …
1.3.6.1.4.1.994.3.4.7.19.1.65ColumnpSlot2LiveLevelread-onlycurrentThis field is used in the following card types: discrete-inputs - The current level of the alarm. onboard-sensors - The level of the current state of the onboa…
1.3.6.1.4.1.994.3.4.7.19.1.66ColumnpSlot2LiveRawread-onlycurrentThis field is used in the following card types: onboard-sensors - The current reading from the onboard sensor. This value will always be between the threshold …
1.3.6.1.4.1.994.3.4.7.19.1.67ColumnpSlot2LiveTimeread-onlycurrentThis field is used in the following card types: discrete-inputs - The time of the last change of state. onboard-sensors - The time of the last event. analog-In…
1.3.6.1.4.1.994.3.4.7.19.1.68ColumnpSlot2Presentread-onlycurrentThis field is used in the following card types: serial-ports - If set to true, the serial port exists. If set to false the serial port does not exist.
1.3.6.1.4.1.994.3.4.7.19.1.71ColumnpSlot2OutputAutoPkgread-writecurrentThis field is used in the following card types: discrete-outputs - When this control point is opened, this is the package that the alarm point is located.
1.3.6.1.4.1.994.3.4.7.19.1.72ColumnpSlot2VoltageRangeread-onlycurrentThis field is used in the following card types: onboard-sensors - The voltage range. analog-Inputs - The voltage range. analog-Sensors - The voltage range.
1.3.6.1.4.1.994.3.4.7.19.1.73ColumnpSlot2IPPortNumread-writecurrentThis field is used in the following card types: serial-ports - IP port number of the target device.
1.3.6.1.4.1.994.3.4.7.19.1.75ColumnpSlot2IOFormatread-onlycurrentThis field is used in the following card types: discrete-inputs - The io format of discrete inputs. discrete-outputs - The io format of discrete outputs. seria…
1.3.6.1.4.1.994.3.4.7.19.1.76ColumnpSlot2PortTyperead-onlycurrentThis field is used in the following card types: serial-ports - The type of serial port.
1.3.6.1.4.1.994.3.4.7.19.1.116ColumnpSlot2TL1SIDread-writecurrentThis field is used in the following card types: discrete-inputs - discrete-outputs - onboard-sensors - analog-Inputs - analog-Sensors -
1.3.6.1.4.1.994.3.4.7.19.1.117ColumnpSlot2TL1CONDread-writecurrentThis field is used in the following card types: discrete-inputs - discrete-outputs - onboard-sensors - analog-Inputs - analog-Sensors -
1.3.6.1.4.1.994.3.4.7.19.1.118ColumnpSlot2TL1Eqptread-writecurrentThis field is used in the following card types: discrete-inputs - onboard-sensors - analog-Inputs - analog-Sensors -
1.3.6.1.4.1.994.3.4.7.19.1.119ColumnpSlot2TL1Envread-writecurrentThis field is used in the following card types: discrete-inputs - onboard-sensors - analog-Inputs - analog-Sensors -
1.3.6.1.4.1.994.3.4.7.19.1.120ColumnpSlot2TL1Srveffread-writecurrentThis field is used in the following card types: discrete-inputs - onboard-sensors - analog-Inputs - analog-Sensors -
1.3.6.1.4.1.994.3.4.7.19.1.121ColumnpSlot2TL1Locnread-writecurrentThis field is used in the following card types: discrete-inputs - onboard-sensors - analog-Inputs - analog-Sensors -
1.3.6.1.4.1.994.3.4.7.19.1.122ColumnpSlot2TL1Dirnread-writecurrentThis field is used in the following card types: discrete-inputs - onboard-sensors - analog-Inputs - analog-Sensors -
1.3.6.1.4.1.994.3.4.7.19.1.131ColumnpSlot2SensorTyperead-onlycurrentThis field is used in the following card types: onboard-sensors - The type of sensor. analog-Inputs - The type of sensor. analog-Sensors - The type of sensor.
1.3.6.1.4.1.994.3.4.7.19.1.999ColumnpSlot2Indexread-onlycurrentIndex.
1.3.6.1.4.1.994.3.4.7.20TablepSlot3Tablenot-accessiblecurrentTable for configuration of Slot3
1.3.6.1.4.1.994.3.4.7.20.1RowpSlot3Entrynot-accessiblecurrentEntry for configuration table of Slot3
1.3.6.1.4.1.994.3.4.7.20.1.3ColumnpSlot3Descriptionread-writecurrentThis field is used in the following card types: discrete-inputs - Description of the alarm point. discrete-outputs - Description of the control point. serial-p…
1.3.6.1.4.1.994.3.4.7.20.1.4ColumnpSlot3Desc0read-writecurrentThis field is used in the following card types: discrete-inputs - Description of the off state. discrete-outputs - Description when the control point is open. …
1.3.6.1.4.1.994.3.4.7.20.1.5ColumnpSlot3Desc1read-writecurrentThis field is used in the following card types: discrete-inputs - Description of the on state. discrete-outputs - Description when the control point is closed.…
1.3.6.1.4.1.994.3.4.7.20.1.6ColumnpSlot3Desc2read-writecurrentThis field is used in the following card types: onboard-sensors - The description for values between threshold 2 and threshold 3. analog-Inputs - The descripti…
1.3.6.1.4.1.994.3.4.7.20.1.7ColumnpSlot3Desc3read-writecurrentThis field is used in the following card types: onboard-sensors - The description for values between threshold 3 and threshold 4. analog-Inputs - The descripti…
1.3.6.1.4.1.994.3.4.7.20.1.8ColumnpSlot3Desc4read-writecurrentThis field is used in the following card types: onboard-sensors - The description for values between threshold 4 and threshold 5. analog-Inputs - The descripti…
1.3.6.1.4.1.994.3.4.7.20.1.9ColumnpSlot3Desc5read-writecurrentThis field is used in the following card types: analog-Inputs - Description for a communications failure to the sensor. analog-Sensors - Description for a comm…
1.3.6.1.4.1.994.3.4.7.20.1.10ColumnpSlot3Configuredread-writecurrentThis field is used in the following card types: discrete-inputs - If set to true, changes of state will be reported. If set to false, not change of states will…
1.3.6.1.4.1.994.3.4.7.20.1.11ColumnpSlot3SendEmailread-writecurrentThis field is used in the following card types: discrete-inputs - If set to true, an email will be sent on a change of state. If false, no email will be sent. …
1.3.6.1.4.1.994.3.4.7.20.1.12ColumnpSlot3SendSNMPTrapread-writecurrentThis field is used in the following card types: discrete-inputs - If set to true, an SNMP trap will be sent on a change of state. If false, no SNMP trap will b…
1.3.6.1.4.1.994.3.4.7.20.1.14ColumnpSlot3IpAddressread-writecurrentThis field is used in the following card types: serial-ports - IP Address of the target device.
1.3.6.1.4.1.994.3.4.7.20.1.17ColumnpSlot3Level0read-writecurrentThis field is used in the following card types: discrete-inputs - Level of the off state. discrete-outputs - Level of the control point when open. onboard-sens…
1.3.6.1.4.1.994.3.4.7.20.1.18ColumnpSlot3Level1read-writecurrentThis field is used in the following card types: discrete-inputs - Level of the on state. discrete-outputs - Level of the control point when closed. onboard-sen…
1.3.6.1.4.1.994.3.4.7.20.1.19ColumnpSlot3Level2read-writecurrentThis field is used in the following card types: onboard-sensors - The level for values between threshold 2 and threshold 3. analog-Inputs - The level for value…
1.3.6.1.4.1.994.3.4.7.20.1.20ColumnpSlot3Level3read-writecurrentThis field is used in the following card types: onboard-sensors - The level for values between threshold 3 and threshold 4. analog-Inputs - The level for value…
1.3.6.1.4.1.994.3.4.7.20.1.21ColumnpSlot3Level4read-writecurrentThis field is used in the following card types: onboard-sensors - The level for values between threshold 4 and threshold 5. analog-Inputs - The level for value…
1.3.6.1.4.1.994.3.4.7.20.1.22ColumnpSlot3Level5read-writecurrentThis field is used in the following card types: analog-Inputs - Level of a communications failure to the sensor. analog-Sensors - Level of a communications fai…
1.3.6.1.4.1.994.3.4.7.20.1.23ColumnpSlot3ReadPeriodread-writecurrentThis field is used in the following card types: serial-ports - Inactivity timeout (in minutes).
1.3.6.1.4.1.994.3.4.7.20.1.28ColumnpSlot3Thresh0read-onlycurrentThis field is used in the following card types: onboard-sensors - This is the minimun analog value. analog-Inputs - This is the maximum analog value. analog-Se…
1.3.6.1.4.1.994.3.4.7.20.1.29ColumnpSlot3Thresh1read-writecurrentThis field is used in the following card types: onboard-sensors - This is the first threshold value. analog-Inputs - This is the first threshold value. analog-…
1.3.6.1.4.1.994.3.4.7.20.1.30ColumnpSlot3Thresh2read-writecurrentThis field is used in the following card types: onboard-sensors - This is the second threshold value. analog-Inputs - This is the second threshold value. analo…
1.3.6.1.4.1.994.3.4.7.20.1.31ColumnpSlot3Thresh3read-writecurrentThis field is used in the following card types: onboard-sensors - This is the third threshold value. analog-Inputs - This is the third threshold value. analog-…
1.3.6.1.4.1.994.3.4.7.20.1.32ColumnpSlot3Thresh4read-writecurrentThis field is used in the following card types: onboard-sensors - This is the fourth threshold value. analog-Inputs - This is the fourth threshold value. analo…
1.3.6.1.4.1.994.3.4.7.20.1.33ColumnpSlot3Thresh5read-onlycurrentThis field is used in the following card types: onboard-sensors - This is the maximum threshold value. analog-Inputs - This is the minimum threshold value. ana…
1.3.6.1.4.1.994.3.4.7.20.1.44ColumnpSlot3ContactStyleread-writecurrentThis field is used in the following card types: discrete-inputs - Determines the type of contact.
1.3.6.1.4.1.994.3.4.7.20.1.46ColumnpSlot3Unitsread-onlycurrentThis field is used in the following card types: onboard-sensors - Description of the units of measurement. analog-Inputs - Description of the units of measurem…
1.3.6.1.4.1.994.3.4.7.20.1.47ColumnpSlot3OutputModeread-writecurrentThis field is used in the following card types: discrete-outputs - Defines the different ways a control point can be activated.
1.3.6.1.4.1.994.3.4.7.20.1.48ColumnpSlot3OutputStateread-writecurrentThis field is used in the following card types: discrete-outputs - A value of 0 will open the control point. A value of 1 will close the control point.
1.3.6.1.4.1.994.3.4.7.20.1.49ColumnpSlot3OutputAutoread-writecurrentThis field is used in the following card types: discrete-outputs - When this control point is opened, this alarm point will change state to the on state.
1.3.6.1.4.1.994.3.4.7.20.1.57ColumnpSlot3BaudRateread-writecurrentThis field is used in the following card types: serial-ports - Baud rate of the serial port.
1.3.6.1.4.1.994.3.4.7.20.1.58ColumnpSlot3DataBitsread-writecurrentThis field is used in the following card types: serial-ports - Number of data bit for the serial port.
1.3.6.1.4.1.994.3.4.7.20.1.59ColumnpSlot3Parityread-writecurrentThis field is used in the following card types: serial-ports - Parity of the serial port.
1.3.6.1.4.1.994.3.4.7.20.1.60ColumnpSlot3StopBitsread-writecurrentThis field is used in the following card types: serial-ports - Number of stop bits for the serial port.
1.3.6.1.4.1.994.3.4.7.20.1.61ColumnpSlot3Protocolread-writecurrentThis field is used in the following card types: serial-ports - Protocol the serial port is speaking.
1.3.6.1.4.1.994.3.4.7.20.1.62ColumnpSlot3SerialRTSread-writecurrentThis field is used in the following card types: serial-ports - Request To Send (RTS) setting for the serial port.
1.3.6.1.4.1.994.3.4.7.20.1.63ColumnpSlot3SerialCTSread-writecurrentThis field is used in the following card types: serial-ports - Clear To Send (CTS) setting for the serial port.
1.3.6.1.4.1.994.3.4.7.20.1.64ColumnpSlot3LiveDescriptionread-onlycurrentThis field is used in the following card types: discrete-inputs - The current description of the alarm state. onboard-sensors - The description of the current …
1.3.6.1.4.1.994.3.4.7.20.1.65ColumnpSlot3LiveLevelread-onlycurrentThis field is used in the following card types: discrete-inputs - The current level of the alarm. onboard-sensors - The level of the current state of the onboa…
1.3.6.1.4.1.994.3.4.7.20.1.66ColumnpSlot3LiveRawread-onlycurrentThis field is used in the following card types: onboard-sensors - The current reading from the onboard sensor. This value will always be between the threshold …
1.3.6.1.4.1.994.3.4.7.20.1.67ColumnpSlot3LiveTimeread-onlycurrentThis field is used in the following card types: discrete-inputs - The time of the last change of state. onboard-sensors - The time of the last event. analog-In…
1.3.6.1.4.1.994.3.4.7.20.1.68ColumnpSlot3Presentread-onlycurrentThis field is used in the following card types: serial-ports - If set to true, the serial port exists. If set to false the serial port does not exist.
1.3.6.1.4.1.994.3.4.7.20.1.71ColumnpSlot3OutputAutoPkgread-writecurrentThis field is used in the following card types: discrete-outputs - When this control point is opened, this is the package that the alarm point is located.
1.3.6.1.4.1.994.3.4.7.20.1.72ColumnpSlot3VoltageRangeread-onlycurrentThis field is used in the following card types: onboard-sensors - The voltage range. analog-Inputs - The voltage range. analog-Sensors - The voltage range.
1.3.6.1.4.1.994.3.4.7.20.1.73ColumnpSlot3IPPortNumread-writecurrentThis field is used in the following card types: serial-ports - IP port number of the target device.
1.3.6.1.4.1.994.3.4.7.20.1.75ColumnpSlot3IOFormatread-onlycurrentThis field is used in the following card types: discrete-inputs - The io format of discrete inputs. discrete-outputs - The io format of discrete outputs. seria…
1.3.6.1.4.1.994.3.4.7.20.1.76ColumnpSlot3PortTyperead-onlycurrentThis field is used in the following card types: serial-ports - The type of serial port.
1.3.6.1.4.1.994.3.4.7.20.1.116ColumnpSlot3TL1SIDread-writecurrentThis field is used in the following card types: discrete-inputs - discrete-outputs - onboard-sensors - analog-Inputs - analog-Sensors -
1.3.6.1.4.1.994.3.4.7.20.1.117ColumnpSlot3TL1CONDread-writecurrentThis field is used in the following card types: discrete-inputs - discrete-outputs - onboard-sensors - analog-Inputs - analog-Sensors -
1.3.6.1.4.1.994.3.4.7.20.1.118ColumnpSlot3TL1Eqptread-writecurrentThis field is used in the following card types: discrete-inputs - onboard-sensors - analog-Inputs - analog-Sensors -
1.3.6.1.4.1.994.3.4.7.20.1.119ColumnpSlot3TL1Envread-writecurrentThis field is used in the following card types: discrete-inputs - onboard-sensors - analog-Inputs - analog-Sensors -
1.3.6.1.4.1.994.3.4.7.20.1.120ColumnpSlot3TL1Srveffread-writecurrentThis field is used in the following card types: discrete-inputs - onboard-sensors - analog-Inputs - analog-Sensors -
1.3.6.1.4.1.994.3.4.7.20.1.121ColumnpSlot3TL1Locnread-writecurrentThis field is used in the following card types: discrete-inputs - onboard-sensors - analog-Inputs - analog-Sensors -
1.3.6.1.4.1.994.3.4.7.20.1.122ColumnpSlot3TL1Dirnread-writecurrentThis field is used in the following card types: discrete-inputs - onboard-sensors - analog-Inputs - analog-Sensors -
1.3.6.1.4.1.994.3.4.7.20.1.131ColumnpSlot3SensorTyperead-onlycurrentThis field is used in the following card types: onboard-sensors - The type of sensor. analog-Inputs - The type of sensor. analog-Sensors - The type of sensor.
1.3.6.1.4.1.994.3.4.7.20.1.999ColumnpSlot3Indexread-onlycurrentIndex.
1.3.6.1.4.1.994.3.4.7.21TablepSlot4Tablenot-accessiblecurrentTable for configuration of Slot4
1.3.6.1.4.1.994.3.4.7.21.1RowpSlot4Entrynot-accessiblecurrentEntry for configuration table of Slot4
1.3.6.1.4.1.994.3.4.7.21.1.3ColumnpSlot4Descriptionread-writecurrentThis field is used in the following card types: discrete-inputs - Description of the alarm point. discrete-outputs - Description of the control point. serial-p…
1.3.6.1.4.1.994.3.4.7.21.1.4ColumnpSlot4Desc0read-writecurrentThis field is used in the following card types: discrete-inputs - Description of the off state. discrete-outputs - Description when the control point is open. …
1.3.6.1.4.1.994.3.4.7.21.1.5ColumnpSlot4Desc1read-writecurrentThis field is used in the following card types: discrete-inputs - Description of the on state. discrete-outputs - Description when the control point is closed.…
1.3.6.1.4.1.994.3.4.7.21.1.6ColumnpSlot4Desc2read-writecurrentThis field is used in the following card types: onboard-sensors - The description for values between threshold 2 and threshold 3. analog-Inputs - The descripti…
1.3.6.1.4.1.994.3.4.7.21.1.7ColumnpSlot4Desc3read-writecurrentThis field is used in the following card types: onboard-sensors - The description for values between threshold 3 and threshold 4. analog-Inputs - The descripti…
1.3.6.1.4.1.994.3.4.7.21.1.8ColumnpSlot4Desc4read-writecurrentThis field is used in the following card types: onboard-sensors - The description for values between threshold 4 and threshold 5. analog-Inputs - The descripti…
1.3.6.1.4.1.994.3.4.7.21.1.9ColumnpSlot4Desc5read-writecurrentThis field is used in the following card types: analog-Inputs - Description for a communications failure to the sensor. analog-Sensors - Description for a comm…
1.3.6.1.4.1.994.3.4.7.21.1.10ColumnpSlot4Configuredread-writecurrentThis field is used in the following card types: discrete-inputs - If set to true, changes of state will be reported. If set to false, not change of states will…
1.3.6.1.4.1.994.3.4.7.21.1.11ColumnpSlot4SendEmailread-writecurrentThis field is used in the following card types: discrete-inputs - If set to true, an email will be sent on a change of state. If false, no email will be sent. …
1.3.6.1.4.1.994.3.4.7.21.1.12ColumnpSlot4SendSNMPTrapread-writecurrentThis field is used in the following card types: discrete-inputs - If set to true, an SNMP trap will be sent on a change of state. If false, no SNMP trap will b…
1.3.6.1.4.1.994.3.4.7.21.1.14ColumnpSlot4IpAddressread-writecurrentThis field is used in the following card types: serial-ports - IP Address of the target device.
1.3.6.1.4.1.994.3.4.7.21.1.17ColumnpSlot4Level0read-writecurrentThis field is used in the following card types: discrete-inputs - Level of the off state. discrete-outputs - Level of the control point when open. onboard-sens…
1.3.6.1.4.1.994.3.4.7.21.1.18ColumnpSlot4Level1read-writecurrentThis field is used in the following card types: discrete-inputs - Level of the on state. discrete-outputs - Level of the control point when closed. onboard-sen…
1.3.6.1.4.1.994.3.4.7.21.1.19ColumnpSlot4Level2read-writecurrentThis field is used in the following card types: onboard-sensors - The level for values between threshold 2 and threshold 3. analog-Inputs - The level for value…
1.3.6.1.4.1.994.3.4.7.21.1.20ColumnpSlot4Level3read-writecurrentThis field is used in the following card types: onboard-sensors - The level for values between threshold 3 and threshold 4. analog-Inputs - The level for value…
1.3.6.1.4.1.994.3.4.7.21.1.21ColumnpSlot4Level4read-writecurrentThis field is used in the following card types: onboard-sensors - The level for values between threshold 4 and threshold 5. analog-Inputs - The level for value…
1.3.6.1.4.1.994.3.4.7.21.1.22ColumnpSlot4Level5read-writecurrentThis field is used in the following card types: analog-Inputs - Level of a communications failure to the sensor. analog-Sensors - Level of a communications fai…
1.3.6.1.4.1.994.3.4.7.21.1.23ColumnpSlot4ReadPeriodread-writecurrentThis field is used in the following card types: serial-ports - Inactivity timeout (in minutes).
1.3.6.1.4.1.994.3.4.7.21.1.28ColumnpSlot4Thresh0read-onlycurrentThis field is used in the following card types: onboard-sensors - This is the minimun analog value. analog-Inputs - This is the maximum analog value. analog-Se…
1.3.6.1.4.1.994.3.4.7.21.1.29ColumnpSlot4Thresh1read-writecurrentThis field is used in the following card types: onboard-sensors - This is the first threshold value. analog-Inputs - This is the first threshold value. analog-…
1.3.6.1.4.1.994.3.4.7.21.1.30ColumnpSlot4Thresh2read-writecurrentThis field is used in the following card types: onboard-sensors - This is the second threshold value. analog-Inputs - This is the second threshold value. analo…
1.3.6.1.4.1.994.3.4.7.21.1.31ColumnpSlot4Thresh3read-writecurrentThis field is used in the following card types: onboard-sensors - This is the third threshold value. analog-Inputs - This is the third threshold value. analog-…
1.3.6.1.4.1.994.3.4.7.21.1.32ColumnpSlot4Thresh4read-writecurrentThis field is used in the following card types: onboard-sensors - This is the fourth threshold value. analog-Inputs - This is the fourth threshold value. analo…
1.3.6.1.4.1.994.3.4.7.21.1.33ColumnpSlot4Thresh5read-onlycurrentThis field is used in the following card types: onboard-sensors - This is the maximum threshold value. analog-Inputs - This is the minimum threshold value. ana…
1.3.6.1.4.1.994.3.4.7.21.1.44ColumnpSlot4ContactStyleread-writecurrentThis field is used in the following card types: discrete-inputs - Determines the type of contact.
1.3.6.1.4.1.994.3.4.7.21.1.46ColumnpSlot4Unitsread-onlycurrentThis field is used in the following card types: onboard-sensors - Description of the units of measurement. analog-Inputs - Description of the units of measurem…
1.3.6.1.4.1.994.3.4.7.21.1.47ColumnpSlot4OutputModeread-writecurrentThis field is used in the following card types: discrete-outputs - Defines the different ways a control point can be activated.
1.3.6.1.4.1.994.3.4.7.21.1.48ColumnpSlot4OutputStateread-writecurrentThis field is used in the following card types: discrete-outputs - A value of 0 will open the control point. A value of 1 will close the control point.
1.3.6.1.4.1.994.3.4.7.21.1.49ColumnpSlot4OutputAutoread-writecurrentThis field is used in the following card types: discrete-outputs - When this control point is opened, this alarm point will change state to the on state.
1.3.6.1.4.1.994.3.4.7.21.1.57ColumnpSlot4BaudRateread-writecurrentThis field is used in the following card types: serial-ports - Baud rate of the serial port.
1.3.6.1.4.1.994.3.4.7.21.1.58ColumnpSlot4DataBitsread-writecurrentThis field is used in the following card types: serial-ports - Number of data bit for the serial port.
1.3.6.1.4.1.994.3.4.7.21.1.59ColumnpSlot4Parityread-writecurrentThis field is used in the following card types: serial-ports - Parity of the serial port.
1.3.6.1.4.1.994.3.4.7.21.1.60ColumnpSlot4StopBitsread-writecurrentThis field is used in the following card types: serial-ports - Number of stop bits for the serial port.
1.3.6.1.4.1.994.3.4.7.21.1.61ColumnpSlot4Protocolread-writecurrentThis field is used in the following card types: serial-ports - Protocol the serial port is speaking.
1.3.6.1.4.1.994.3.4.7.21.1.62ColumnpSlot4SerialRTSread-writecurrentThis field is used in the following card types: serial-ports - Request To Send (RTS) setting for the serial port.
1.3.6.1.4.1.994.3.4.7.21.1.63ColumnpSlot4SerialCTSread-writecurrentThis field is used in the following card types: serial-ports - Clear To Send (CTS) setting for the serial port.
1.3.6.1.4.1.994.3.4.7.21.1.64ColumnpSlot4LiveDescriptionread-onlycurrentThis field is used in the following card types: discrete-inputs - The current description of the alarm state. onboard-sensors - The description of the current …
1.3.6.1.4.1.994.3.4.7.21.1.65ColumnpSlot4LiveLevelread-onlycurrentThis field is used in the following card types: discrete-inputs - The current level of the alarm. onboard-sensors - The level of the current state of the onboa…
1.3.6.1.4.1.994.3.4.7.21.1.66ColumnpSlot4LiveRawread-onlycurrentThis field is used in the following card types: onboard-sensors - The current reading from the onboard sensor. This value will always be between the threshold …
1.3.6.1.4.1.994.3.4.7.21.1.67ColumnpSlot4LiveTimeread-onlycurrentThis field is used in the following card types: discrete-inputs - The time of the last change of state. onboard-sensors - The time of the last event. analog-In…
1.3.6.1.4.1.994.3.4.7.21.1.68ColumnpSlot4Presentread-onlycurrentThis field is used in the following card types: serial-ports - If set to true, the serial port exists. If set to false the serial port does not exist.
1.3.6.1.4.1.994.3.4.7.21.1.71ColumnpSlot4OutputAutoPkgread-writecurrentThis field is used in the following card types: discrete-outputs - When this control point is opened, this is the package that the alarm point is located.
1.3.6.1.4.1.994.3.4.7.21.1.72ColumnpSlot4VoltageRangeread-onlycurrentThis field is used in the following card types: onboard-sensors - The voltage range. analog-Inputs - The voltage range. analog-Sensors - The voltage range.
1.3.6.1.4.1.994.3.4.7.21.1.73ColumnpSlot4IPPortNumread-writecurrentThis field is used in the following card types: serial-ports - IP port number of the target device.
1.3.6.1.4.1.994.3.4.7.21.1.75ColumnpSlot4IOFormatread-onlycurrentThis field is used in the following card types: discrete-inputs - The io format of discrete inputs. discrete-outputs - The io format of discrete outputs. seria…
1.3.6.1.4.1.994.3.4.7.21.1.76ColumnpSlot4PortTyperead-onlycurrentThis field is used in the following card types: serial-ports - The type of serial port.
1.3.6.1.4.1.994.3.4.7.21.1.116ColumnpSlot4TL1SIDread-writecurrentThis field is used in the following card types: discrete-inputs - discrete-outputs - onboard-sensors - analog-Inputs - analog-Sensors -
1.3.6.1.4.1.994.3.4.7.21.1.117ColumnpSlot4TL1CONDread-writecurrentThis field is used in the following card types: discrete-inputs - discrete-outputs - onboard-sensors - analog-Inputs - analog-Sensors -
1.3.6.1.4.1.994.3.4.7.21.1.118ColumnpSlot4TL1Eqptread-writecurrentThis field is used in the following card types: discrete-inputs - onboard-sensors - analog-Inputs - analog-Sensors -
1.3.6.1.4.1.994.3.4.7.21.1.119ColumnpSlot4TL1Envread-writecurrentThis field is used in the following card types: discrete-inputs - onboard-sensors - analog-Inputs - analog-Sensors -
1.3.6.1.4.1.994.3.4.7.21.1.120ColumnpSlot4TL1Srveffread-writecurrentThis field is used in the following card types: discrete-inputs - onboard-sensors - analog-Inputs - analog-Sensors -
1.3.6.1.4.1.994.3.4.7.21.1.121ColumnpSlot4TL1Locnread-writecurrentThis field is used in the following card types: discrete-inputs - onboard-sensors - analog-Inputs - analog-Sensors -
1.3.6.1.4.1.994.3.4.7.21.1.122ColumnpSlot4TL1Dirnread-writecurrentThis field is used in the following card types: discrete-inputs - onboard-sensors - analog-Inputs - analog-Sensors -
1.3.6.1.4.1.994.3.4.7.21.1.131ColumnpSlot4SensorTyperead-onlycurrentThis field is used in the following card types: onboard-sensors - The type of sensor. analog-Inputs - The type of sensor. analog-Sensors - The type of sensor.
1.3.6.1.4.1.994.3.4.7.21.1.999ColumnpSlot4Indexread-onlycurrentIndex.
1.3.6.1.4.1.994.3.4.7.22TablepSlot5Tablenot-accessiblecurrentTable for configuration of Slot5
1.3.6.1.4.1.994.3.4.7.22.1RowpSlot5Entrynot-accessiblecurrentEntry for configuration table of Slot5
1.3.6.1.4.1.994.3.4.7.22.1.3ColumnpSlot5Descriptionread-writecurrentThis field is used in the following card types: discrete-inputs - Description of the alarm point. discrete-outputs - Description of the control point. serial-p…
1.3.6.1.4.1.994.3.4.7.22.1.4ColumnpSlot5Desc0read-writecurrentThis field is used in the following card types: discrete-inputs - Description of the off state. discrete-outputs - Description when the control point is open. …
1.3.6.1.4.1.994.3.4.7.22.1.5ColumnpSlot5Desc1read-writecurrentThis field is used in the following card types: discrete-inputs - Description of the on state. discrete-outputs - Description when the control point is closed.…
1.3.6.1.4.1.994.3.4.7.22.1.6ColumnpSlot5Desc2read-writecurrentThis field is used in the following card types: onboard-sensors - The description for values between threshold 2 and threshold 3. analog-Inputs - The descripti…
1.3.6.1.4.1.994.3.4.7.22.1.7ColumnpSlot5Desc3read-writecurrentThis field is used in the following card types: onboard-sensors - The description for values between threshold 3 and threshold 4. analog-Inputs - The descripti…
1.3.6.1.4.1.994.3.4.7.22.1.8ColumnpSlot5Desc4read-writecurrentThis field is used in the following card types: onboard-sensors - The description for values between threshold 4 and threshold 5. analog-Inputs - The descripti…
1.3.6.1.4.1.994.3.4.7.22.1.9ColumnpSlot5Desc5read-writecurrentThis field is used in the following card types: analog-Inputs - Description for a communications failure to the sensor. analog-Sensors - Description for a comm…
1.3.6.1.4.1.994.3.4.7.22.1.10ColumnpSlot5Configuredread-writecurrentThis field is used in the following card types: discrete-inputs - If set to true, changes of state will be reported. If set to false, not change of states will…
1.3.6.1.4.1.994.3.4.7.22.1.11ColumnpSlot5SendEmailread-writecurrentThis field is used in the following card types: discrete-inputs - If set to true, an email will be sent on a change of state. If false, no email will be sent. …
1.3.6.1.4.1.994.3.4.7.22.1.12ColumnpSlot5SendSNMPTrapread-writecurrentThis field is used in the following card types: discrete-inputs - If set to true, an SNMP trap will be sent on a change of state. If false, no SNMP trap will b…
1.3.6.1.4.1.994.3.4.7.22.1.14ColumnpSlot5IpAddressread-writecurrentThis field is used in the following card types: serial-ports - IP Address of the target device.
1.3.6.1.4.1.994.3.4.7.22.1.17ColumnpSlot5Level0read-writecurrentThis field is used in the following card types: discrete-inputs - Level of the off state. discrete-outputs - Level of the control point when open. onboard-sens…
1.3.6.1.4.1.994.3.4.7.22.1.18ColumnpSlot5Level1read-writecurrentThis field is used in the following card types: discrete-inputs - Level of the on state. discrete-outputs - Level of the control point when closed. onboard-sen…
1.3.6.1.4.1.994.3.4.7.22.1.19ColumnpSlot5Level2read-writecurrentThis field is used in the following card types: onboard-sensors - The level for values between threshold 2 and threshold 3. analog-Inputs - The level for value…
1.3.6.1.4.1.994.3.4.7.22.1.20ColumnpSlot5Level3read-writecurrentThis field is used in the following card types: onboard-sensors - The level for values between threshold 3 and threshold 4. analog-Inputs - The level for value…
1.3.6.1.4.1.994.3.4.7.22.1.21ColumnpSlot5Level4read-writecurrentThis field is used in the following card types: onboard-sensors - The level for values between threshold 4 and threshold 5. analog-Inputs - The level for value…
1.3.6.1.4.1.994.3.4.7.22.1.22ColumnpSlot5Level5read-writecurrentThis field is used in the following card types: analog-Inputs - Level of a communications failure to the sensor. analog-Sensors - Level of a communications fai…
1.3.6.1.4.1.994.3.4.7.22.1.23ColumnpSlot5ReadPeriodread-writecurrentThis field is used in the following card types: serial-ports - Inactivity timeout (in minutes).
1.3.6.1.4.1.994.3.4.7.22.1.28ColumnpSlot5Thresh0read-onlycurrentThis field is used in the following card types: onboard-sensors - This is the minimun analog value. analog-Inputs - This is the maximum analog value. analog-Se…
1.3.6.1.4.1.994.3.4.7.22.1.29ColumnpSlot5Thresh1read-writecurrentThis field is used in the following card types: onboard-sensors - This is the first threshold value. analog-Inputs - This is the first threshold value. analog-…
1.3.6.1.4.1.994.3.4.7.22.1.30ColumnpSlot5Thresh2read-writecurrentThis field is used in the following card types: onboard-sensors - This is the second threshold value. analog-Inputs - This is the second threshold value. analo…
1.3.6.1.4.1.994.3.4.7.22.1.31ColumnpSlot5Thresh3read-writecurrentThis field is used in the following card types: onboard-sensors - This is the third threshold value. analog-Inputs - This is the third threshold value. analog-…
1.3.6.1.4.1.994.3.4.7.22.1.32ColumnpSlot5Thresh4read-writecurrentThis field is used in the following card types: onboard-sensors - This is the fourth threshold value. analog-Inputs - This is the fourth threshold value. analo…
1.3.6.1.4.1.994.3.4.7.22.1.33ColumnpSlot5Thresh5read-onlycurrentThis field is used in the following card types: onboard-sensors - This is the maximum threshold value. analog-Inputs - This is the minimum threshold value. ana…
1.3.6.1.4.1.994.3.4.7.22.1.44ColumnpSlot5ContactStyleread-writecurrentThis field is used in the following card types: discrete-inputs - Determines the type of contact.
1.3.6.1.4.1.994.3.4.7.22.1.46ColumnpSlot5Unitsread-onlycurrentThis field is used in the following card types: onboard-sensors - Description of the units of measurement. analog-Inputs - Description of the units of measurem…
1.3.6.1.4.1.994.3.4.7.22.1.47ColumnpSlot5OutputModeread-writecurrentThis field is used in the following card types: discrete-outputs - Defines the different ways a control point can be activated.
1.3.6.1.4.1.994.3.4.7.22.1.48ColumnpSlot5OutputStateread-writecurrentThis field is used in the following card types: discrete-outputs - A value of 0 will open the control point. A value of 1 will close the control point.
1.3.6.1.4.1.994.3.4.7.22.1.49ColumnpSlot5OutputAutoread-writecurrentThis field is used in the following card types: discrete-outputs - When this control point is opened, this alarm point will change state to the on state.
1.3.6.1.4.1.994.3.4.7.22.1.57ColumnpSlot5BaudRateread-writecurrentThis field is used in the following card types: serial-ports - Baud rate of the serial port.
1.3.6.1.4.1.994.3.4.7.22.1.58ColumnpSlot5DataBitsread-writecurrentThis field is used in the following card types: serial-ports - Number of data bit for the serial port.
1.3.6.1.4.1.994.3.4.7.22.1.59ColumnpSlot5Parityread-writecurrentThis field is used in the following card types: serial-ports - Parity of the serial port.
1.3.6.1.4.1.994.3.4.7.22.1.60ColumnpSlot5StopBitsread-writecurrentThis field is used in the following card types: serial-ports - Number of stop bits for the serial port.
1.3.6.1.4.1.994.3.4.7.22.1.61ColumnpSlot5Protocolread-writecurrentThis field is used in the following card types: serial-ports - Protocol the serial port is speaking.
1.3.6.1.4.1.994.3.4.7.22.1.62ColumnpSlot5SerialRTSread-writecurrentThis field is used in the following card types: serial-ports - Request To Send (RTS) setting for the serial port.
1.3.6.1.4.1.994.3.4.7.22.1.63ColumnpSlot5SerialCTSread-writecurrentThis field is used in the following card types: serial-ports - Clear To Send (CTS) setting for the serial port.
1.3.6.1.4.1.994.3.4.7.22.1.64ColumnpSlot5LiveDescriptionread-onlycurrentThis field is used in the following card types: discrete-inputs - The current description of the alarm state. onboard-sensors - The description of the current …
1.3.6.1.4.1.994.3.4.7.22.1.65ColumnpSlot5LiveLevelread-onlycurrentThis field is used in the following card types: discrete-inputs - The current level of the alarm. onboard-sensors - The level of the current state of the onboa…
1.3.6.1.4.1.994.3.4.7.22.1.66ColumnpSlot5LiveRawread-onlycurrentThis field is used in the following card types: onboard-sensors - The current reading from the onboard sensor. This value will always be between the threshold …
1.3.6.1.4.1.994.3.4.7.22.1.67ColumnpSlot5LiveTimeread-onlycurrentThis field is used in the following card types: discrete-inputs - The time of the last change of state. onboard-sensors - The time of the last event. analog-In…
1.3.6.1.4.1.994.3.4.7.22.1.68ColumnpSlot5Presentread-onlycurrentThis field is used in the following card types: serial-ports - If set to true, the serial port exists. If set to false the serial port does not exist.
1.3.6.1.4.1.994.3.4.7.22.1.71ColumnpSlot5OutputAutoPkgread-writecurrentThis field is used in the following card types: discrete-outputs - When this control point is opened, this is the package that the alarm point is located.
1.3.6.1.4.1.994.3.4.7.22.1.72ColumnpSlot5VoltageRangeread-onlycurrentThis field is used in the following card types: onboard-sensors - The voltage range. analog-Inputs - The voltage range. analog-Sensors - The voltage range.
1.3.6.1.4.1.994.3.4.7.22.1.73ColumnpSlot5IPPortNumread-writecurrentThis field is used in the following card types: serial-ports - IP port number of the target device.
1.3.6.1.4.1.994.3.4.7.22.1.75ColumnpSlot5IOFormatread-onlycurrentThis field is used in the following card types: discrete-inputs - The io format of discrete inputs. discrete-outputs - The io format of discrete outputs. seria…
1.3.6.1.4.1.994.3.4.7.22.1.76ColumnpSlot5PortTyperead-onlycurrentThis field is used in the following card types: serial-ports - The type of serial port.
1.3.6.1.4.1.994.3.4.7.22.1.116ColumnpSlot5TL1SIDread-writecurrentThis field is used in the following card types: discrete-inputs - discrete-outputs - onboard-sensors - analog-Inputs - analog-Sensors -
1.3.6.1.4.1.994.3.4.7.22.1.117ColumnpSlot5TL1CONDread-writecurrentThis field is used in the following card types: discrete-inputs - discrete-outputs - onboard-sensors - analog-Inputs - analog-Sensors -
1.3.6.1.4.1.994.3.4.7.22.1.118ColumnpSlot5TL1Eqptread-writecurrentThis field is used in the following card types: discrete-inputs - onboard-sensors - analog-Inputs - analog-Sensors -
1.3.6.1.4.1.994.3.4.7.22.1.119ColumnpSlot5TL1Envread-writecurrentThis field is used in the following card types: discrete-inputs - onboard-sensors - analog-Inputs - analog-Sensors -
1.3.6.1.4.1.994.3.4.7.22.1.120ColumnpSlot5TL1Srveffread-writecurrentThis field is used in the following card types: discrete-inputs - onboard-sensors - analog-Inputs - analog-Sensors -
1.3.6.1.4.1.994.3.4.7.22.1.121ColumnpSlot5TL1Locnread-writecurrentThis field is used in the following card types: discrete-inputs - onboard-sensors - analog-Inputs - analog-Sensors -
1.3.6.1.4.1.994.3.4.7.22.1.122ColumnpSlot5TL1Dirnread-writecurrentThis field is used in the following card types: discrete-inputs - onboard-sensors - analog-Inputs - analog-Sensors -
1.3.6.1.4.1.994.3.4.7.22.1.131ColumnpSlot5SensorTyperead-onlycurrentThis field is used in the following card types: onboard-sensors - The type of sensor. analog-Inputs - The type of sensor. analog-Sensors - The type of sensor.
1.3.6.1.4.1.994.3.4.7.22.1.999ColumnpSlot5Indexread-onlycurrentIndex.
1.3.6.1.4.1.994.3.4.7.23TablepSlot6Tablenot-accessiblecurrentTable for configuration of Slot6
1.3.6.1.4.1.994.3.4.7.23.1RowpSlot6Entrynot-accessiblecurrentEntry for configuration table of Slot6
1.3.6.1.4.1.994.3.4.7.23.1.3ColumnpSlot6Descriptionread-writecurrentThis field is used in the following card types: discrete-inputs - Description of the alarm point. discrete-outputs - Description of the control point. serial-p…
1.3.6.1.4.1.994.3.4.7.23.1.4ColumnpSlot6Desc0read-writecurrentThis field is used in the following card types: discrete-inputs - Description of the off state. discrete-outputs - Description when the control point is open. …
1.3.6.1.4.1.994.3.4.7.23.1.5ColumnpSlot6Desc1read-writecurrentThis field is used in the following card types: discrete-inputs - Description of the on state. discrete-outputs - Description when the control point is closed.…
1.3.6.1.4.1.994.3.4.7.23.1.6ColumnpSlot6Desc2read-writecurrentThis field is used in the following card types: onboard-sensors - The description for values between threshold 2 and threshold 3. analog-Inputs - The descripti…
1.3.6.1.4.1.994.3.4.7.23.1.7ColumnpSlot6Desc3read-writecurrentThis field is used in the following card types: onboard-sensors - The description for values between threshold 3 and threshold 4. analog-Inputs - The descripti…
1.3.6.1.4.1.994.3.4.7.23.1.8ColumnpSlot6Desc4read-writecurrentThis field is used in the following card types: onboard-sensors - The description for values between threshold 4 and threshold 5. analog-Inputs - The descripti…
1.3.6.1.4.1.994.3.4.7.23.1.9ColumnpSlot6Desc5read-writecurrentThis field is used in the following card types: analog-Inputs - Description for a communications failure to the sensor. analog-Sensors - Description for a comm…
1.3.6.1.4.1.994.3.4.7.23.1.10ColumnpSlot6Configuredread-writecurrentThis field is used in the following card types: discrete-inputs - If set to true, changes of state will be reported. If set to false, not change of states will…
1.3.6.1.4.1.994.3.4.7.23.1.11ColumnpSlot6SendEmailread-writecurrentThis field is used in the following card types: discrete-inputs - If set to true, an email will be sent on a change of state. If false, no email will be sent. …
1.3.6.1.4.1.994.3.4.7.23.1.12ColumnpSlot6SendSNMPTrapread-writecurrentThis field is used in the following card types: discrete-inputs - If set to true, an SNMP trap will be sent on a change of state. If false, no SNMP trap will b…
1.3.6.1.4.1.994.3.4.7.23.1.14ColumnpSlot6IpAddressread-writecurrentThis field is used in the following card types: serial-ports - IP Address of the target device.
1.3.6.1.4.1.994.3.4.7.23.1.17ColumnpSlot6Level0read-writecurrentThis field is used in the following card types: discrete-inputs - Level of the off state. discrete-outputs - Level of the control point when open. onboard-sens…
1.3.6.1.4.1.994.3.4.7.23.1.18ColumnpSlot6Level1read-writecurrentThis field is used in the following card types: discrete-inputs - Level of the on state. discrete-outputs - Level of the control point when closed. onboard-sen…
1.3.6.1.4.1.994.3.4.7.23.1.19ColumnpSlot6Level2read-writecurrentThis field is used in the following card types: onboard-sensors - The level for values between threshold 2 and threshold 3. analog-Inputs - The level for value…
1.3.6.1.4.1.994.3.4.7.23.1.20ColumnpSlot6Level3read-writecurrentThis field is used in the following card types: onboard-sensors - The level for values between threshold 3 and threshold 4. analog-Inputs - The level for value…
1.3.6.1.4.1.994.3.4.7.23.1.21ColumnpSlot6Level4read-writecurrentThis field is used in the following card types: onboard-sensors - The level for values between threshold 4 and threshold 5. analog-Inputs - The level for value…
1.3.6.1.4.1.994.3.4.7.23.1.22ColumnpSlot6Level5read-writecurrentThis field is used in the following card types: analog-Inputs - Level of a communications failure to the sensor. analog-Sensors - Level of a communications fai…
1.3.6.1.4.1.994.3.4.7.23.1.23ColumnpSlot6ReadPeriodread-writecurrentThis field is used in the following card types: serial-ports - Inactivity timeout (in minutes).
1.3.6.1.4.1.994.3.4.7.23.1.28ColumnpSlot6Thresh0read-onlycurrentThis field is used in the following card types: onboard-sensors - This is the minimun analog value. analog-Inputs - This is the maximum analog value. analog-Se…
1.3.6.1.4.1.994.3.4.7.23.1.29ColumnpSlot6Thresh1read-writecurrentThis field is used in the following card types: onboard-sensors - This is the first threshold value. analog-Inputs - This is the first threshold value. analog-…
1.3.6.1.4.1.994.3.4.7.23.1.30ColumnpSlot6Thresh2read-writecurrentThis field is used in the following card types: onboard-sensors - This is the second threshold value. analog-Inputs - This is the second threshold value. analo…
1.3.6.1.4.1.994.3.4.7.23.1.31ColumnpSlot6Thresh3read-writecurrentThis field is used in the following card types: onboard-sensors - This is the third threshold value. analog-Inputs - This is the third threshold value. analog-…
1.3.6.1.4.1.994.3.4.7.23.1.32ColumnpSlot6Thresh4read-writecurrentThis field is used in the following card types: onboard-sensors - This is the fourth threshold value. analog-Inputs - This is the fourth threshold value. analo…
1.3.6.1.4.1.994.3.4.7.23.1.33ColumnpSlot6Thresh5read-onlycurrentThis field is used in the following card types: onboard-sensors - This is the maximum threshold value. analog-Inputs - This is the minimum threshold value. ana…
1.3.6.1.4.1.994.3.4.7.23.1.44ColumnpSlot6ContactStyleread-writecurrentThis field is used in the following card types: discrete-inputs - Determines the type of contact.
1.3.6.1.4.1.994.3.4.7.23.1.46ColumnpSlot6Unitsread-onlycurrentThis field is used in the following card types: onboard-sensors - Description of the units of measurement. analog-Inputs - Description of the units of measurem…
1.3.6.1.4.1.994.3.4.7.23.1.47ColumnpSlot6OutputModeread-writecurrentThis field is used in the following card types: discrete-outputs - Defines the different ways a control point can be activated.
1.3.6.1.4.1.994.3.4.7.23.1.48ColumnpSlot6OutputStateread-writecurrentThis field is used in the following card types: discrete-outputs - A value of 0 will open the control point. A value of 1 will close the control point.
1.3.6.1.4.1.994.3.4.7.23.1.49ColumnpSlot6OutputAutoread-writecurrentThis field is used in the following card types: discrete-outputs - When this control point is opened, this alarm point will change state to the on state.
1.3.6.1.4.1.994.3.4.7.23.1.57ColumnpSlot6BaudRateread-writecurrentThis field is used in the following card types: serial-ports - Baud rate of the serial port.
1.3.6.1.4.1.994.3.4.7.23.1.58ColumnpSlot6DataBitsread-writecurrentThis field is used in the following card types: serial-ports - Number of data bit for the serial port.
1.3.6.1.4.1.994.3.4.7.23.1.59ColumnpSlot6Parityread-writecurrentThis field is used in the following card types: serial-ports - Parity of the serial port.
1.3.6.1.4.1.994.3.4.7.23.1.60ColumnpSlot6StopBitsread-writecurrentThis field is used in the following card types: serial-ports - Number of stop bits for the serial port.
1.3.6.1.4.1.994.3.4.7.23.1.61ColumnpSlot6Protocolread-writecurrentThis field is used in the following card types: serial-ports - Protocol the serial port is speaking.
1.3.6.1.4.1.994.3.4.7.23.1.62ColumnpSlot6SerialRTSread-writecurrentThis field is used in the following card types: serial-ports - Request To Send (RTS) setting for the serial port.
1.3.6.1.4.1.994.3.4.7.23.1.63ColumnpSlot6SerialCTSread-writecurrentThis field is used in the following card types: serial-ports - Clear To Send (CTS) setting for the serial port.
1.3.6.1.4.1.994.3.4.7.23.1.64ColumnpSlot6LiveDescriptionread-onlycurrentThis field is used in the following card types: discrete-inputs - The current description of the alarm state. onboard-sensors - The description of the current …
1.3.6.1.4.1.994.3.4.7.23.1.65ColumnpSlot6LiveLevelread-onlycurrentThis field is used in the following card types: discrete-inputs - The current level of the alarm. onboard-sensors - The level of the current state of the onboa…
1.3.6.1.4.1.994.3.4.7.23.1.66ColumnpSlot6LiveRawread-onlycurrentThis field is used in the following card types: onboard-sensors - The current reading from the onboard sensor. This value will always be between the threshold …
1.3.6.1.4.1.994.3.4.7.23.1.67ColumnpSlot6LiveTimeread-onlycurrentThis field is used in the following card types: discrete-inputs - The time of the last change of state. onboard-sensors - The time of the last event. analog-In…
1.3.6.1.4.1.994.3.4.7.23.1.68ColumnpSlot6Presentread-onlycurrentThis field is used in the following card types: serial-ports - If set to true, the serial port exists. If set to false the serial port does not exist.
1.3.6.1.4.1.994.3.4.7.23.1.71ColumnpSlot6OutputAutoPkgread-writecurrentThis field is used in the following card types: discrete-outputs - When this control point is opened, this is the package that the alarm point is located.
1.3.6.1.4.1.994.3.4.7.23.1.72ColumnpSlot6VoltageRangeread-onlycurrentThis field is used in the following card types: onboard-sensors - The voltage range. analog-Inputs - The voltage range. analog-Sensors - The voltage range.
1.3.6.1.4.1.994.3.4.7.23.1.73ColumnpSlot6IPPortNumread-writecurrentThis field is used in the following card types: serial-ports - IP port number of the target device.
1.3.6.1.4.1.994.3.4.7.23.1.75ColumnpSlot6IOFormatread-onlycurrentThis field is used in the following card types: discrete-inputs - The io format of discrete inputs. discrete-outputs - The io format of discrete outputs. seria…
1.3.6.1.4.1.994.3.4.7.23.1.76ColumnpSlot6PortTyperead-onlycurrentThis field is used in the following card types: serial-ports - The type of serial port.
1.3.6.1.4.1.994.3.4.7.23.1.116ColumnpSlot6TL1SIDread-writecurrentThis field is used in the following card types: discrete-inputs - discrete-outputs - onboard-sensors - analog-Inputs - analog-Sensors -
1.3.6.1.4.1.994.3.4.7.23.1.117ColumnpSlot6TL1CONDread-writecurrentThis field is used in the following card types: discrete-inputs - discrete-outputs - onboard-sensors - analog-Inputs - analog-Sensors -
1.3.6.1.4.1.994.3.4.7.23.1.118ColumnpSlot6TL1Eqptread-writecurrentThis field is used in the following card types: discrete-inputs - onboard-sensors - analog-Inputs - analog-Sensors -
1.3.6.1.4.1.994.3.4.7.23.1.119ColumnpSlot6TL1Envread-writecurrentThis field is used in the following card types: discrete-inputs - onboard-sensors - analog-Inputs - analog-Sensors -
1.3.6.1.4.1.994.3.4.7.23.1.120ColumnpSlot6TL1Srveffread-writecurrentThis field is used in the following card types: discrete-inputs - onboard-sensors - analog-Inputs - analog-Sensors -
1.3.6.1.4.1.994.3.4.7.23.1.121ColumnpSlot6TL1Locnread-writecurrentThis field is used in the following card types: discrete-inputs - onboard-sensors - analog-Inputs - analog-Sensors -
1.3.6.1.4.1.994.3.4.7.23.1.122ColumnpSlot6TL1Dirnread-writecurrentThis field is used in the following card types: discrete-inputs - onboard-sensors - analog-Inputs - analog-Sensors -
1.3.6.1.4.1.994.3.4.7.23.1.131ColumnpSlot6SensorTyperead-onlycurrentThis field is used in the following card types: onboard-sensors - The type of sensor. analog-Inputs - The type of sensor. analog-Sensors - The type of sensor.
1.3.6.1.4.1.994.3.4.7.23.1.999ColumnpSlot6Indexread-onlycurrentIndex.
1.3.6.1.4.1.994.3.4.7.24TablepNetPortsTablenot-accessiblecurrentTable for configuration of NetPorts
1.3.6.1.4.1.994.3.4.7.24.1RowpNetPortsEntrynot-accessiblecurrentEntry for configuration table of NetPorts
1.3.6.1.4.1.994.3.4.7.24.1.3ColumnpNetPortsDescriptionread-onlycurrentDescription of the static network ports.
1.3.6.1.4.1.994.3.4.7.24.1.23ColumnpNetPortsReadPeriodread-writecurrentInactivity timeout (in minutes).
1.3.6.1.4.1.994.3.4.7.24.1.73ColumnpNetPortsIPPortNumread-writecurrentIP port number to use when connecting to this network port.
1.3.6.1.4.1.994.3.4.7.24.1.999ColumnpNetPortsIndexread-onlycurrentIndex.
1.3.6.1.4.1.994.3.4.7.25NodewirelessModem
1.3.6.1.4.1.994.3.4.7.25.78ScalarwirelessModemBackupIPAddressread-onlycurrentWireless Modem IP Address.
1.3.6.1.4.1.994.3.4.7.25.81ScalarwirelessModemTimeread-writecurrentWireless modem 24 hour reset time (hh:mm:ss)
1.3.6.1.4.1.994.3.4.7.25.96ScalarwirelessModemTransmitread-writecurrentThe string that will be sent to the modem.
1.3.6.1.4.1.994.3.4.7.25.97ScalarwirelessModemUseWirelessNetworkread-writecurrentDetermines if modem tries to connect to wireless network.
1.3.6.1.4.1.994.3.4.7.25.98ScalarwirelessModemUseResetTimeread-writecurrentDetermines if the modem resets at reset time.
1.3.6.1.4.1.994.3.4.7.25.99ScalarwirelessModemResponseWaitTimeread-writecurrentResponse Timeout (s)
1.3.6.1.4.1.994.3.4.7.25.115ScalarwirelessModemSecondaryread-writecurrentDetermines if the modem can use accept a dynamic (local) IP.
1.3.6.1.4.1.994.3.4.7.26NodewebmonSecurity
1.3.6.1.4.1.994.3.4.7.26.55ScalarwebmonSecurityUserLevelread-writecurrentThis is the default user level. Anyone who has access to this device will have these permissions without logging in. One of the following masks from each group…
1.3.6.1.4.1.994.3.4.7.26.77ScalarwebmonSecurityUnsecuredread-writecurrentAllow unsecured configuration for SNMP.
1.3.6.1.4.1.994.3.4.7.27NodedateTime
1.3.6.1.4.1.994.3.4.7.27.10ScalardateTimeConfiguredread-writecurrentDetermines whether or not NTP will be used to set system time.
1.3.6.1.4.1.994.3.4.7.27.14ScalardateTimeIpAddressread-writecurrentTime Server IP Address
1.3.6.1.4.1.994.3.4.7.27.53ScalardateTimeDaylightSavingread-writecurrentDetermines if Daylight Savings is automatically adjusted.
1.3.6.1.4.1.994.3.4.7.27.80ScalardateTimeDateread-writecurrentThis is the system date.
1.3.6.1.4.1.994.3.4.7.27.81ScalardateTimeTimeread-writecurrentThis is the system time.
1.3.6.1.4.1.994.3.4.7.27.88ScalardateTimeNegOffsetread-writecurrentTrue if a negative offset from UTC is desired
1.3.6.1.4.1.994.3.4.7.27.89ScalardateTimeUTCOffsetread-writecurrentTime offset of local time compared to UTC
1.3.6.1.4.1.994.3.4.7.28TablepDCMProtocolTablenot-accessiblecurrentTable for configuration of DCMProtocol
1.3.6.1.4.1.994.3.4.7.28.1RowpDCMProtocolEntrynot-accessiblecurrentEntry for configuration table of DCMProtocol
1.3.6.1.4.1.994.3.4.7.28.1.3ColumnpDCMProtocolDescriptionread-onlycurrentDescription of the input device that DCM will poll.
1.3.6.1.4.1.994.3.4.7.28.1.10ColumnpDCMProtocolConfiguredread-writecurrentIf set to true, this input will be polled in DCM. If set to false, it will not be polled.
1.3.6.1.4.1.994.3.4.7.28.1.83ColumnpDCMProtocolBaseDCMAddressread-writecurrentBase DCM address for this input device.
1.3.6.1.4.1.994.3.4.7.28.1.999ColumnpDCMProtocolIndexread-onlycurrentIndex.
1.3.6.1.4.1.994.3.4.7.29TablepdialOutTablenot-accessiblecurrentTable for configuration of dialOut
1.3.6.1.4.1.994.3.4.7.29.1RowpdialOutEntrynot-accessiblecurrentEntry for configuration table of dialOut
1.3.6.1.4.1.994.3.4.7.29.1.10ColumnpdialOutConfiguredread-writecurrentDetermines whether or not dial ou will be used to send SNMP traps.
1.3.6.1.4.1.994.3.4.7.29.1.25ColumnpdialOutNameread-writecurrentDial out Username
1.3.6.1.4.1.994.3.4.7.29.1.26ColumnpdialOutPasswordread-writecurrentPassword to use when dialing out
1.3.6.1.4.1.994.3.4.7.29.1.79ColumnpdialOutDialOutNumberread-writecurrentNumber to dial for dial out
1.3.6.1.4.1.994.3.4.7.29.1.999ColumnpdialOutIndexread-onlycurrentIndex.
1.3.6.1.4.1.994.3.4.7.30TablepderivedDiscreteTablenot-accessiblecurrentTable for configuration of derivedDiscrete
1.3.6.1.4.1.994.3.4.7.30.1RowpderivedDiscreteEntrynot-accessiblecurrentEntry for configuration table of derivedDiscrete
1.3.6.1.4.1.994.3.4.7.30.1.3ColumnpderivedDiscreteDescriptionread-writecurrentDescription of the derived alarm point.
1.3.6.1.4.1.994.3.4.7.30.1.4ColumnpderivedDiscreteDesc0read-writecurrentDescription of the off state.
1.3.6.1.4.1.994.3.4.7.30.1.5ColumnpderivedDiscreteDesc1read-writecurrentDescription of the on state.
1.3.6.1.4.1.994.3.4.7.30.1.10ColumnpderivedDiscreteConfiguredread-writecurrentIf set to true, changes of state will be reported. If set to false, not change of states will be reported.
1.3.6.1.4.1.994.3.4.7.30.1.11ColumnpderivedDiscreteSendEmailread-writecurrentIf set to true, an email will be sent on a change of state. If false, no email will be sent.
1.3.6.1.4.1.994.3.4.7.30.1.12ColumnpderivedDiscreteSendSNMPTrapread-writecurrentIf set to true, an SNMP trap will be sent on a change of state. If false, no SNMP trap will be sent.
1.3.6.1.4.1.994.3.4.7.30.1.17ColumnpderivedDiscreteLevel0read-writecurrentLevel of the off state.
1.3.6.1.4.1.994.3.4.7.30.1.18ColumnpderivedDiscreteLevel1read-writecurrentLevel of the on state.
1.3.6.1.4.1.994.3.4.7.30.1.64ColumnpderivedDiscreteLiveDescriptionread-onlycurrentThe current description of the alarm state.
1.3.6.1.4.1.994.3.4.7.30.1.65ColumnpderivedDiscreteLiveLevelread-onlycurrentThe current level of the alarm.
1.3.6.1.4.1.994.3.4.7.30.1.67ColumnpderivedDiscreteLiveTimeread-onlycurrentThe time of the last change of state.
1.3.6.1.4.1.994.3.4.7.30.1.90ColumnpderivedDiscreteElementAPkgread-writecurrentPackage where the alarm point is located for element A.
1.3.6.1.4.1.994.3.4.7.30.1.91ColumnpderivedDiscreteElementAPointread-writecurrentAlarm point for element A.
1.3.6.1.4.1.994.3.4.7.30.1.92ColumnpderivedDiscreteElementBPkgread-writecurrentPackage where the alarm point is located for element B.
1.3.6.1.4.1.994.3.4.7.30.1.93ColumnpderivedDiscreteElementBPointread-writecurrentAlarm point for element B.
1.3.6.1.4.1.994.3.4.7.30.1.94ColumnpderivedDiscreteDiscreteFormularead-writecurrentThe formula that will be used to compute the derived alarm.
1.3.6.1.4.1.994.3.4.7.30.1.116ColumnpderivedDiscreteTL1SIDread-writecurrent(TL1) System ID associated with this item.
1.3.6.1.4.1.994.3.4.7.30.1.117ColumnpderivedDiscreteTL1CONDread-writecurrent(TL1) Condition text associated with this item.
1.3.6.1.4.1.994.3.4.7.30.1.118ColumnpderivedDiscreteTL1Eqptread-writecurrent(TL1) EQPT field associated with this item.
1.3.6.1.4.1.994.3.4.7.30.1.119ColumnpderivedDiscreteTL1Envread-writecurrent(TL1) Environmental field associated with this item.
1.3.6.1.4.1.994.3.4.7.30.1.120ColumnpderivedDiscreteTL1Srveffread-writecurrent(TL1) Service Effecting field associated with this item.
1.3.6.1.4.1.994.3.4.7.30.1.121ColumnpderivedDiscreteTL1Locnread-writecurrent(TL1) Location field associated with this item.
1.3.6.1.4.1.994.3.4.7.30.1.122ColumnpderivedDiscreteTL1Dirnread-writecurrent(TL1) Direction field associated with this item.
1.3.6.1.4.1.994.3.4.7.30.1.999ColumnpderivedDiscreteIndexread-onlycurrentIndex.
1.3.6.1.4.1.994.3.4.7.31Nodelicense
1.3.6.1.4.1.994.3.4.7.31.3ScalarlicenseDescriptionread-onlycurrentThis describes the status of the license
1.3.6.1.4.1.994.3.4.7.31.84ScalarlicenseLicenseKeyread-writecurrentThis is the License Key.
1.3.6.1.4.1.994.3.4.7.31.85ScalarlicenseExpiresread-onlycurrentThis is the date the current License will expire.
1.3.6.1.4.1.994.3.4.7.31.124ScalarlicenseAllowTL1read-onlycurrentThis describes the status of TL1 support in the license
1.3.6.1.4.1.994.3.4.7.32Tablepe2aHostTablenot-accessiblecurrentTable for configuration of e2aHost
1.3.6.1.4.1.994.3.4.7.32.1Rowpe2aHostEntrynot-accessiblecurrentEntry for configuration table of e2aHost
1.3.6.1.4.1.994.3.4.7.32.1.3Columnpe2aHostDescriptionread-writecurrentDescription of the connection.
1.3.6.1.4.1.994.3.4.7.32.1.10Columnpe2aHostConfiguredread-writecurrentIf set to true, this route will be used by E2A.
1.3.6.1.4.1.994.3.4.7.32.1.14Columnpe2aHostIpAddressread-writecurrentThe IP address of the remote device.
1.3.6.1.4.1.994.3.4.7.32.1.17Columnpe2aHostLevel0read-writecurrentAlarm level associated with the online state.
1.3.6.1.4.1.994.3.4.7.32.1.18Columnpe2aHostLevel1read-writecurrentAlarm level associated with the offline state.
1.3.6.1.4.1.994.3.4.7.32.1.19Columnpe2aHostLevel2read-writecurrentAlarm level associated with the connecting state.
1.3.6.1.4.1.994.3.4.7.32.1.37Columnpe2aHostRosterIDread-writecurrentSerial port number to use when connecting to WebMon.
1.3.6.1.4.1.994.3.4.7.32.1.56Columnpe2aHostPollAddressread-writecurrentThe E2A address of the remote device.
1.3.6.1.4.1.994.3.4.7.32.1.73Columnpe2aHostIPPortNumread-writecurrentIP port number to use when connecting to the remote device.
1.3.6.1.4.1.994.3.4.7.32.1.116Columnpe2aHostTL1SIDread-writecurrent(TL1) System ID associated with this item.
1.3.6.1.4.1.994.3.4.7.32.1.117Columnpe2aHostTL1CONDread-writecurrent(TL1) Condition text associated with this item.
1.3.6.1.4.1.994.3.4.7.32.1.118Columnpe2aHostTL1Eqptread-writecurrent(TL1) EQPT field associated with this item.
1.3.6.1.4.1.994.3.4.7.32.1.119Columnpe2aHostTL1Envread-writecurrent(TL1) Environmental field associated with this item.
1.3.6.1.4.1.994.3.4.7.32.1.120Columnpe2aHostTL1Srveffread-writecurrent(TL1) Service Effecting field associated with this item.
1.3.6.1.4.1.994.3.4.7.32.1.121Columnpe2aHostTL1Locnread-writecurrent(TL1) Location field associated with this item.
1.3.6.1.4.1.994.3.4.7.32.1.122Columnpe2aHostTL1Dirnread-writecurrent(TL1) Direction field associated with this item.
1.3.6.1.4.1.994.3.4.7.32.1.999Columnpe2aHostIndexread-onlycurrentIndex.
1.3.6.1.4.1.994.3.4.7.33TablepderivedAnalogTablenot-accessiblecurrentTable for configuration of derivedAnalog
1.3.6.1.4.1.994.3.4.7.33.1RowpderivedAnalogEntrynot-accessiblecurrentEntry for configuration table of derivedAnalog
1.3.6.1.4.1.994.3.4.7.33.1.3ColumnpderivedAnalogDescriptionread-writecurrentDescription of the derived alarm point.
1.3.6.1.4.1.994.3.4.7.33.1.4ColumnpderivedAnalogDesc0read-writecurrentThe description for derived values between threshold 0 and threshold 1.
1.3.6.1.4.1.994.3.4.7.33.1.5ColumnpderivedAnalogDesc1read-writecurrentThe description for derived values between threshold 1 and threshold 2.
1.3.6.1.4.1.994.3.4.7.33.1.6ColumnpderivedAnalogDesc2read-writecurrentThe description for derived values between threshold 2 and threshold 3.
1.3.6.1.4.1.994.3.4.7.33.1.7ColumnpderivedAnalogDesc3read-writecurrentThe description for derived values between threshold 3 and threshold 4.
1.3.6.1.4.1.994.3.4.7.33.1.8ColumnpderivedAnalogDesc4read-writecurrentThe description for derived values between threshold 4 and threshold 5.
1.3.6.1.4.1.994.3.4.7.33.1.10ColumnpderivedAnalogConfiguredread-writecurrentIf set to true, changes of state will be reported. If set to false, not change of states will be reported.
1.3.6.1.4.1.994.3.4.7.33.1.11ColumnpderivedAnalogSendEmailread-writecurrentIf set to true, an email will be sent on a change of state. If false, no email will be sent.
1.3.6.1.4.1.994.3.4.7.33.1.12ColumnpderivedAnalogSendSNMPTrapread-writecurrentIf set to true, an SNMP trap will be sent on a change of state. If false, no SNMP trap will be sent.
1.3.6.1.4.1.994.3.4.7.33.1.17ColumnpderivedAnalogLevel0read-writecurrentThe level for derived values between threshold 0 and threshold 1.
1.3.6.1.4.1.994.3.4.7.33.1.18ColumnpderivedAnalogLevel1read-writecurrentThe level for derived values between threshold 1 and threshold 2.
1.3.6.1.4.1.994.3.4.7.33.1.19ColumnpderivedAnalogLevel2read-writecurrentThe level for derived values between threshold 2 and threshold 3.
1.3.6.1.4.1.994.3.4.7.33.1.20ColumnpderivedAnalogLevel3read-writecurrentThe level for derived values between threshold 3 and threshold 4.
1.3.6.1.4.1.994.3.4.7.33.1.21ColumnpderivedAnalogLevel4read-writecurrentThe level for derived values between threshold 4 and threshold 5.
1.3.6.1.4.1.994.3.4.7.33.1.28ColumnpderivedAnalogThresh0read-writecurrentThis is the maximum analog derived value.
1.3.6.1.4.1.994.3.4.7.33.1.29ColumnpderivedAnalogThresh1read-writecurrentThis is the first threshold derived value.
1.3.6.1.4.1.994.3.4.7.33.1.30ColumnpderivedAnalogThresh2read-writecurrentThis is the second threshold derived value.
1.3.6.1.4.1.994.3.4.7.33.1.31ColumnpderivedAnalogThresh3read-writecurrentThis is the third threshold derived value.
1.3.6.1.4.1.994.3.4.7.33.1.32ColumnpderivedAnalogThresh4read-writecurrentThis is the fourth threshold derived value.
1.3.6.1.4.1.994.3.4.7.33.1.33ColumnpderivedAnalogThresh5read-writecurrentThis is the minimum threshold derived value.
1.3.6.1.4.1.994.3.4.7.33.1.46ColumnpderivedAnalogUnitsread-writecurrentDescription of the units of measurement.
1.3.6.1.4.1.994.3.4.7.33.1.64ColumnpderivedAnalogLiveDescriptionread-onlycurrentThe current description of the alarm state.
1.3.6.1.4.1.994.3.4.7.33.1.65ColumnpderivedAnalogLiveLevelread-onlycurrentThe current level of the alarm.
1.3.6.1.4.1.994.3.4.7.33.1.66ColumnpderivedAnalogLiveRawread-onlycurrentThe current derived reading from the analog devices. This value will alwaysbe between the threshold 0 and threshold 5 values.
1.3.6.1.4.1.994.3.4.7.33.1.67ColumnpderivedAnalogLiveTimeread-onlycurrentThe time of the last change of state.
1.3.6.1.4.1.994.3.4.7.33.1.90ColumnpderivedAnalogElementAPkgread-writecurrentPackage where the alarm point is located for element A.
1.3.6.1.4.1.994.3.4.7.33.1.91ColumnpderivedAnalogElementAPointread-writecurrentAlarm point for element A.
1.3.6.1.4.1.994.3.4.7.33.1.92ColumnpderivedAnalogElementBPkgread-writecurrentPackage where the alarm point is located for element B.
1.3.6.1.4.1.994.3.4.7.33.1.93ColumnpderivedAnalogElementBPointread-writecurrentAlarm point for element B.
1.3.6.1.4.1.994.3.4.7.33.1.95ColumnpderivedAnalogFormularead-writecurrentThe formula that will be used to compute the derived alarm.
1.3.6.1.4.1.994.3.4.7.33.1.116ColumnpderivedAnalogTL1SIDread-writecurrent(TL1) System ID associated with this item.
1.3.6.1.4.1.994.3.4.7.33.1.117ColumnpderivedAnalogTL1CONDread-writecurrent(TL1) Condition text associated with this item.
1.3.6.1.4.1.994.3.4.7.33.1.118ColumnpderivedAnalogTL1Eqptread-writecurrent(TL1) EQPT field associated with this item.
1.3.6.1.4.1.994.3.4.7.33.1.119ColumnpderivedAnalogTL1Envread-writecurrent(TL1) Environmental field associated with this item.
1.3.6.1.4.1.994.3.4.7.33.1.120ColumnpderivedAnalogTL1Srveffread-writecurrent(TL1) Service Effecting field associated with this item.
1.3.6.1.4.1.994.3.4.7.33.1.121ColumnpderivedAnalogTL1Locnread-writecurrent(TL1) Location field associated with this item.
1.3.6.1.4.1.994.3.4.7.33.1.122ColumnpderivedAnalogTL1Dirnread-writecurrent(TL1) Direction field associated with this item.
1.3.6.1.4.1.994.3.4.7.33.1.999ColumnpderivedAnalogIndexread-onlycurrentIndex.
1.3.6.1.4.1.994.3.4.7.34TablepgpsTablenot-accessiblecurrentTable for configuration of gps
1.3.6.1.4.1.994.3.4.7.34.1RowpgpsEntrynot-accessiblecurrentEntry for configuration table of gps
1.3.6.1.4.1.994.3.4.7.34.1.3ColumnpgpsDescriptionread-onlycurrentDescription of the onboard device.
1.3.6.1.4.1.994.3.4.7.34.1.4ColumnpgpsDesc0read-writecurrentThe description for values between threshold 0 and threshold 1.
1.3.6.1.4.1.994.3.4.7.34.1.5ColumnpgpsDesc1read-writecurrentThe description for values between threshold 1 and threshold 2.
1.3.6.1.4.1.994.3.4.7.34.1.6ColumnpgpsDesc2read-writecurrentThe description for values between threshold 2 and threshold 3.
1.3.6.1.4.1.994.3.4.7.34.1.7ColumnpgpsDesc3read-writecurrentThe description for values between threshold 3 and threshold 4.
1.3.6.1.4.1.994.3.4.7.34.1.8ColumnpgpsDesc4read-writecurrentThe description for values between threshold 4 and threshold 5.
1.3.6.1.4.1.994.3.4.7.34.1.10ColumnpgpsConfiguredread-writecurrentIf set to true, the onboard sensors will be used. If set to false the will be ignored.
1.3.6.1.4.1.994.3.4.7.34.1.11ColumnpgpsSendEmailread-writecurrentIf set to true an email event will be set when a threshold is crossed. If set to false no email event will be sent.
1.3.6.1.4.1.994.3.4.7.34.1.12ColumnpgpsSendSNMPTrapread-writecurrentIf set to true an SNMP trap will be set when a threshold is crossed. If set to false no SNMP trap will be sent.
1.3.6.1.4.1.994.3.4.7.34.1.17ColumnpgpsLevel0read-writecurrentThe level for values between threshold 0 and threshold 1.
1.3.6.1.4.1.994.3.4.7.34.1.18ColumnpgpsLevel1read-writecurrentThe level for values between threshold 1 and threshold 2.
1.3.6.1.4.1.994.3.4.7.34.1.19ColumnpgpsLevel2read-writecurrentThe level for values between threshold 2 and threshold 3.
1.3.6.1.4.1.994.3.4.7.34.1.20ColumnpgpsLevel3read-writecurrentThe level for values between threshold 3 and threshold 4.
1.3.6.1.4.1.994.3.4.7.34.1.21ColumnpgpsLevel4read-writecurrentThe level for values between threshold 4 and threshold 5.
1.3.6.1.4.1.994.3.4.7.34.1.28ColumnpgpsThresh0read-onlycurrentThis is the minimun analog value.
1.3.6.1.4.1.994.3.4.7.34.1.29ColumnpgpsThresh1read-writecurrentThis is the first threshold value.
1.3.6.1.4.1.994.3.4.7.34.1.30ColumnpgpsThresh2read-writecurrentThis is the second threshold value.
1.3.6.1.4.1.994.3.4.7.34.1.31ColumnpgpsThresh3read-writecurrentThis is the third threshold value.
1.3.6.1.4.1.994.3.4.7.34.1.32ColumnpgpsThresh4read-writecurrentThis is the fourth threshold value.
1.3.6.1.4.1.994.3.4.7.34.1.33ColumnpgpsThresh5read-onlycurrentThis is the maximum threshold value.
1.3.6.1.4.1.994.3.4.7.34.1.46ColumnpgpsUnitsread-onlycurrentDescription of the units of measurement.
1.3.6.1.4.1.994.3.4.7.34.1.64ColumnpgpsLiveDescriptionread-onlycurrentThe description of the current state of the onboard sensor
1.3.6.1.4.1.994.3.4.7.34.1.65ColumnpgpsLiveLevelread-onlycurrentThe level of the current state of the onboard sensor.
1.3.6.1.4.1.994.3.4.7.34.1.66ColumnpgpsLiveRawread-onlycurrentThe current reading from the onboard sensor. This value will always be between the threshold 0 and threshold 5 values.
1.3.6.1.4.1.994.3.4.7.34.1.67ColumnpgpsLiveTimeread-onlycurrentThe time of the last event.
1.3.6.1.4.1.994.3.4.7.34.1.116ColumnpgpsTL1SIDread-writecurrent(TL1) System ID associated with this item.
1.3.6.1.4.1.994.3.4.7.34.1.117ColumnpgpsTL1CONDread-writecurrent(TL1) Condition text associated with this item.
1.3.6.1.4.1.994.3.4.7.34.1.118ColumnpgpsTL1Eqptread-writecurrent(TL1) EQPT field associated with this item.
1.3.6.1.4.1.994.3.4.7.34.1.119ColumnpgpsTL1Envread-writecurrent(TL1) Environmental field associated with this item.
1.3.6.1.4.1.994.3.4.7.34.1.120ColumnpgpsTL1Srveffread-writecurrent(TL1) Service Effecting field associated with this item.
1.3.6.1.4.1.994.3.4.7.34.1.121ColumnpgpsTL1Locnread-writecurrent(TL1) Location field associated with this item.
1.3.6.1.4.1.994.3.4.7.34.1.122ColumnpgpsTL1Dirnread-writecurrent(TL1) Direction field associated with this item.
1.3.6.1.4.1.994.3.4.7.34.1.999ColumnpgpsIndexread-onlycurrentIndex.
1.3.6.1.4.1.994.3.4.7.35TablepportRedirectTablenot-accessiblecurrentTable for configuration of portRedirect
1.3.6.1.4.1.994.3.4.7.35.1RowpportRedirectEntrynot-accessiblecurrentEntry for configuration table of portRedirect
1.3.6.1.4.1.994.3.4.7.35.1.3ColumnpportRedirectDescriptionread-writecurrentDescription of the connection.
1.3.6.1.4.1.994.3.4.7.35.1.10ColumnpportRedirectConfiguredread-writecurrentIf set to true, this route will be allowed.
1.3.6.1.4.1.994.3.4.7.35.1.14ColumnpportRedirectIpAddressread-writecurrentThe IP address of the remote device.
1.3.6.1.4.1.994.3.4.7.35.1.23ColumnpportRedirectReadPeriodread-writecurrentInactivity timeout (in minutes).
1.3.6.1.4.1.994.3.4.7.35.1.37ColumnpportRedirectRosterIDread-writecurrentIP port number to use when connecting to the remote device.
1.3.6.1.4.1.994.3.4.7.35.1.73ColumnpportRedirectIPPortNumread-writecurrentIP port number to use when connecting to WebMon.
1.3.6.1.4.1.994.3.4.7.35.1.999ColumnpportRedirectIndexread-onlycurrentIndex.
1.3.6.1.4.1.994.3.4.7.36TablepscheduleATablenot-accessiblecurrentTable for configuration of scheduleA
1.3.6.1.4.1.994.3.4.7.36.1RowpscheduleAEntrynot-accessiblecurrentEntry for configuration table of scheduleA
1.3.6.1.4.1.994.3.4.7.36.1.102ColumnpscheduleADayOfWeekread-onlycurrentThe day of the week
1.3.6.1.4.1.994.3.4.7.36.1.103ColumnpscheduleAConfiguredStateread-writecurrentThe state of the schedule at the beginning of the day.
1.3.6.1.4.1.994.3.4.7.36.1.104ColumnpscheduleAConfigured1read-writecurrentThe state of the schedule between time markers 1 and 2.
1.3.6.1.4.1.994.3.4.7.36.1.105ColumnpscheduleAConfigured2read-writecurrentThe state of the schedule between time markers 2 and 3.
1.3.6.1.4.1.994.3.4.7.36.1.106ColumnpscheduleAConfigured3read-writecurrentThe state of the schedule between time markers 3 and 4.
1.3.6.1.4.1.994.3.4.7.36.1.107ColumnpscheduleAConfigured4read-writecurrentThe state of the schedule at the end of the day.
1.3.6.1.4.1.994.3.4.7.36.1.108ColumnpscheduleATime0read-onlycurrentTime marker 0, the beginning of the day.
1.3.6.1.4.1.994.3.4.7.36.1.109ColumnpscheduleATime1read-writecurrentTime marker 1.
1.3.6.1.4.1.994.3.4.7.36.1.110ColumnpscheduleATime2read-writecurrentTime marker 2.
1.3.6.1.4.1.994.3.4.7.36.1.111ColumnpscheduleATime3read-writecurrentTime marker 3.
1.3.6.1.4.1.994.3.4.7.36.1.112ColumnpscheduleATime4read-writecurrentTime marker 4.
1.3.6.1.4.1.994.3.4.7.36.1.113ColumnpscheduleATime5read-onlycurrentTime marker 5, the end of the day.
1.3.6.1.4.1.994.3.4.7.36.1.999ColumnpscheduleAIndexread-onlycurrentIndex.
1.3.6.1.4.1.994.3.4.7.37TablepscheduleBTablenot-accessiblecurrentTable for configuration of scheduleB
1.3.6.1.4.1.994.3.4.7.37.1RowpscheduleBEntrynot-accessiblecurrentEntry for configuration table of scheduleB
1.3.6.1.4.1.994.3.4.7.37.1.102ColumnpscheduleBDayOfWeekread-onlycurrentThe day of the week
1.3.6.1.4.1.994.3.4.7.37.1.103ColumnpscheduleBConfiguredStateread-writecurrentThe state of the schedule at the beginning of the day.
1.3.6.1.4.1.994.3.4.7.37.1.104ColumnpscheduleBConfigured1read-writecurrentThe state of the schedule between time markers 1 and 2.
1.3.6.1.4.1.994.3.4.7.37.1.105ColumnpscheduleBConfigured2read-writecurrentThe state of the schedule between time markers 2 and 3.
1.3.6.1.4.1.994.3.4.7.37.1.106ColumnpscheduleBConfigured3read-writecurrentThe state of the schedule between time markers 3 and 4.
1.3.6.1.4.1.994.3.4.7.37.1.107ColumnpscheduleBConfigured4read-writecurrentThe state of the schedule at the end of the day.
1.3.6.1.4.1.994.3.4.7.37.1.108ColumnpscheduleBTime0read-onlycurrentTime marker 0, the beginning of the day.
1.3.6.1.4.1.994.3.4.7.37.1.109ColumnpscheduleBTime1read-writecurrentTime marker 1.
1.3.6.1.4.1.994.3.4.7.37.1.110ColumnpscheduleBTime2read-writecurrentTime marker 2.
1.3.6.1.4.1.994.3.4.7.37.1.111ColumnpscheduleBTime3read-writecurrentTime marker 3.
1.3.6.1.4.1.994.3.4.7.37.1.112ColumnpscheduleBTime4read-writecurrentTime marker 4.
1.3.6.1.4.1.994.3.4.7.37.1.113ColumnpscheduleBTime5read-onlycurrentTime marker 5, the end of the day.
1.3.6.1.4.1.994.3.4.7.37.1.999ColumnpscheduleBIndexread-onlycurrentIndex.
1.3.6.1.4.1.994.3.4.7.38TablepscheduleCTablenot-accessiblecurrentTable for configuration of scheduleC
1.3.6.1.4.1.994.3.4.7.38.1RowpscheduleCEntrynot-accessiblecurrentEntry for configuration table of scheduleC
1.3.6.1.4.1.994.3.4.7.38.1.102ColumnpscheduleCDayOfWeekread-onlycurrentThe day of the week
1.3.6.1.4.1.994.3.4.7.38.1.103ColumnpscheduleCConfiguredStateread-writecurrentThe state of the schedule at the beginning of the day.
1.3.6.1.4.1.994.3.4.7.38.1.104ColumnpscheduleCConfigured1read-writecurrentThe state of the schedule between time markers 1 and 2.
1.3.6.1.4.1.994.3.4.7.38.1.105ColumnpscheduleCConfigured2read-writecurrentThe state of the schedule between time markers 2 and 3.
1.3.6.1.4.1.994.3.4.7.38.1.106ColumnpscheduleCConfigured3read-writecurrentThe state of the schedule between time markers 3 and 4.
1.3.6.1.4.1.994.3.4.7.38.1.107ColumnpscheduleCConfigured4read-writecurrentThe state of the schedule at the end of the day.
1.3.6.1.4.1.994.3.4.7.38.1.108ColumnpscheduleCTime0read-onlycurrentTime marker 0, the beginning of the day.
1.3.6.1.4.1.994.3.4.7.38.1.109ColumnpscheduleCTime1read-writecurrentTime marker 1.
1.3.6.1.4.1.994.3.4.7.38.1.110ColumnpscheduleCTime2read-writecurrentTime marker 2.
1.3.6.1.4.1.994.3.4.7.38.1.111ColumnpscheduleCTime3read-writecurrentTime marker 3.
1.3.6.1.4.1.994.3.4.7.38.1.112ColumnpscheduleCTime4read-writecurrentTime marker 4.
1.3.6.1.4.1.994.3.4.7.38.1.113ColumnpscheduleCTime5read-onlycurrentTime marker 5, the end of the day.
1.3.6.1.4.1.994.3.4.7.38.1.999ColumnpscheduleCIndexread-onlycurrentIndex.
1.3.6.1.4.1.994.3.4.7.39TablepscheduleDTablenot-accessiblecurrentTable for configuration of scheduleD
1.3.6.1.4.1.994.3.4.7.39.1RowpscheduleDEntrynot-accessiblecurrentEntry for configuration table of scheduleD
1.3.6.1.4.1.994.3.4.7.39.1.102ColumnpscheduleDDayOfWeekread-onlycurrentThe day of the week
1.3.6.1.4.1.994.3.4.7.39.1.103ColumnpscheduleDConfiguredStateread-writecurrentThe state of the schedule at the beginning of the day.
1.3.6.1.4.1.994.3.4.7.39.1.104ColumnpscheduleDConfigured1read-writecurrentThe state of the schedule between time markers 1 and 2.
1.3.6.1.4.1.994.3.4.7.39.1.105ColumnpscheduleDConfigured2read-writecurrentThe state of the schedule between time markers 2 and 3.
1.3.6.1.4.1.994.3.4.7.39.1.106ColumnpscheduleDConfigured3read-writecurrentThe state of the schedule between time markers 3 and 4.
1.3.6.1.4.1.994.3.4.7.39.1.107ColumnpscheduleDConfigured4read-writecurrentThe state of the schedule at the end of the day.
1.3.6.1.4.1.994.3.4.7.39.1.108ColumnpscheduleDTime0read-onlycurrentTime marker 0, the beginning of the day.
1.3.6.1.4.1.994.3.4.7.39.1.109ColumnpscheduleDTime1read-writecurrentTime marker 1.
1.3.6.1.4.1.994.3.4.7.39.1.110ColumnpscheduleDTime2read-writecurrentTime marker 2.
1.3.6.1.4.1.994.3.4.7.39.1.111ColumnpscheduleDTime3read-writecurrentTime marker 3.
1.3.6.1.4.1.994.3.4.7.39.1.112ColumnpscheduleDTime4read-writecurrentTime marker 4.
1.3.6.1.4.1.994.3.4.7.39.1.113ColumnpscheduleDTime5read-onlycurrentTime marker 5, the end of the day.
1.3.6.1.4.1.994.3.4.7.39.1.999ColumnpscheduleDIndexread-onlycurrentIndex.
1.3.6.1.4.1.994.3.4.7.40Nodetl1Settings
1.3.6.1.4.1.994.3.4.7.40.123Scalartl1SettingsTL1Issueread-writecurrent(TL1) TL1 issue associated with this device.
1.3.6.1.4.1.994.3.4.7.41TablepDCPFProtocolTablenot-accessiblecurrentTable for configuration of DCPFProtocol
1.3.6.1.4.1.994.3.4.7.41.1RowpDCPFProtocolEntrynot-accessiblecurrentEntry for configuration table of DCPFProtocol
1.3.6.1.4.1.994.3.4.7.41.1.3ColumnpDCPFProtocolDescriptionread-onlycurrentDescription of the input device that DCPF will poll.
1.3.6.1.4.1.994.3.4.7.41.1.10ColumnpDCPFProtocolConfiguredread-writecurrentIf set to true, this input will be polled in DCPF. If set to false, it will not be polled.
1.3.6.1.4.1.994.3.4.7.41.1.127ColumnpDCPFProtocolBaseDCPFDisplayread-writecurrentBase DCPF display for this input device.
1.3.6.1.4.1.994.3.4.7.41.1.999ColumnpDCPFProtocolIndexread-onlycurrentIndex.
1.3.6.1.4.1.994.3.4.7.42NodedcpfSettings
1.3.6.1.4.1.994.3.4.7.42.128ScalardcpfSettingsDCPFAddressread-writecurrentBase DCPF Address.
1.3.6.1.4.1.994.3.4.7.43TablepTABSProtocolTablenot-accessiblecurrentTable for configuration of TABSProtocol
1.3.6.1.4.1.994.3.4.7.43.1RowpTABSProtocolEntrynot-accessiblecurrentEntry for configuration table of TABSProtocol
1.3.6.1.4.1.994.3.4.7.43.1.3ColumnpTABSProtocolDescriptionread-onlycurrentDescription of the input device that TABS will poll.
1.3.6.1.4.1.994.3.4.7.43.1.10ColumnpTABSProtocolConfiguredread-writecurrentIf set to true, this input will be polled in TABS. If set to false, it will not be polled.
1.3.6.1.4.1.994.3.4.7.43.1.129ColumnpTABSProtocolBaseTABSDisplayread-writecurrentBase TABS display for this input device.
1.3.6.1.4.1.994.3.4.7.43.1.999ColumnpTABSProtocolIndexread-onlycurrentIndex.
1.3.6.1.4.1.994.3.4.7.44NodetabsSettings
1.3.6.1.4.1.994.3.4.7.44.130ScalartabsSettingsTABSAddressread-writecurrentBase TABS Address.
1.3.6.1.4.1.994.3.4.7.45TablepsnmpCommandsTablenot-accessiblecurrentTable for configuration of snmpCommands
1.3.6.1.4.1.994.3.4.7.45.1RowpsnmpCommandsEntrynot-accessiblecurrentEntry for configuration table of snmpCommands
1.3.6.1.4.1.994.3.4.7.45.1.3ColumnpsnmpCommandsDescriptionread-writecurrentName for this SNMP command.
1.3.6.1.4.1.994.3.4.7.45.1.10ColumnpsnmpCommandsConfiguredread-writecurrentIf set to true, this command will be sent for matching events. If set to false, it will not be sent.
1.3.6.1.4.1.994.3.4.7.45.1.14ColumnpsnmpCommandsIpAddressread-writecurrentTarget (receiver) IP address of this SNMP command.
1.3.6.1.4.1.994.3.4.7.45.1.39ColumnpsnmpCommandsGetread-writecurrentSNMP community used with this command.
1.3.6.1.4.1.994.3.4.7.45.1.42ColumnpsnmpCommandsSnmpVersionread-writecurrentSNMP version to be used with this command.
1.3.6.1.4.1.994.3.4.7.45.1.49ColumnpsnmpCommandsOutputAutoread-writecurrentSource alarm point for this SNMP command.
1.3.6.1.4.1.994.3.4.7.45.1.71ColumnpsnmpCommandsOutputAutoPkgread-writecurrentPackage where the source alarm point is located.
1.3.6.1.4.1.994.3.4.7.45.1.73ColumnpsnmpCommandsIPPortNumread-writecurrentTarget (receiver) IP port of this SNMP command.
1.3.6.1.4.1.994.3.4.7.45.1.132ColumnpsnmpCommandsOIDread-writecurrentTarget OID used with this command
1.3.6.1.4.1.994.3.4.7.45.1.134ColumnpsnmpCommandsSNMPVarbindTyperead-writecurrentType of value sent to target, if this is a set command.
1.3.6.1.4.1.994.3.4.7.45.1.135ColumnpsnmpCommandsTextNormalread-writecurrentValue sent to target for normal condition for a set command.
1.3.6.1.4.1.994.3.4.7.45.1.136ColumnpsnmpCommandsTextCriticalread-writecurrentValue sent to target for critical condition for a set command.
1.3.6.1.4.1.994.3.4.7.45.1.137ColumnpsnmpCommandsTextMajorread-writecurrentValue sent to target for major condition for a set command.
1.3.6.1.4.1.994.3.4.7.45.1.138ColumnpsnmpCommandsTextMinorread-writecurrentValue sent to target for minor condition for a set command.
1.3.6.1.4.1.994.3.4.7.45.1.139ColumnpsnmpCommandsTextStatusread-writecurrentValue sent to target for status condition for a set command.
1.3.6.1.4.1.994.3.4.7.45.1.999ColumnpsnmpCommandsIndexread-onlycurrentIndex.
1.3.6.1.4.1.994.3.4.7.46NodebattMon
1.3.6.1.4.1.994.3.4.7.46.10ScalarbattMonConfiguredread-writecurrentIf set to true, this command will be sent for matching events. If set to false, it will not be sent.
1.3.6.1.4.1.994.3.4.7.46.49ScalarbattMonOutputAutoread-writecurrentSource alarm point for this SNMP command.
1.3.6.1.4.1.994.3.4.7.46.71ScalarbattMonOutputAutoPkgread-writecurrentPackage where the source alarm point is located.
1.3.6.1.4.1.994.3.4.7.999GroupconfigObjectGroupcurrentDescription.
1.3.6.1.4.1.994.3.4.8Nodetriggers
1.3.6.1.4.1.994.3.4.8.1ScalarresetDeviceread-writecurrentSetting this item to true will cause a reset of the device. Setting this item to false will have no effect.
1.3.6.1.4.1.994.3.4.8.2ScalarcommitAccountChangesread-writecurrentSetting this item to true will cause any user account changes to go into effect immediatly. Setting this item to false will have no effect.
1.3.6.1.4.1.994.3.4.8.3ScalarresendEventsread-writecurrentSetting this item to true will cause the device to resend traps for any standing alarms. Setting this item to false will have no effect.
Type Definitions
NameSyntaxStatusDescription
AnalogStateINTEGER { highHigh(0), high(1), medium(2), low(3), lowLow(4) }currentDefines states for an analog input.
BaudRateINTEGER { baud-300(300), baud-600(600), baud-1200(1200), baud-2400(2400), baud-4800(4800), baud-9600(9600), baud-19200(19200), baud-28800(28800), baud-38400(38400) }currentDefines baud rates for serial communication.
BooleanINTEGER { false(0), true(1) }currentA type with only two states.
CameraStyleINTEGER { d-link-dcs1000(0), sony-snc-rz30n(1), axis-2100(2), d-link-dcs2000(3), d-link-dcs5300(4), axis-210(5), axis-m1103(6) }currentDefines the different types of IP cameras supported.
ConfiguredINTEGER { not-in-use(0), always-in-use(1), schedule-a(2), schedule-b(3), schedule-c(4), schedule-d(5) }currentIn use
ConfiguredStateINTEGER { disabled(0), enabled(1) }current
ConnectivityStateINTEGER { online(0), offline(1) }currentUsed for the state of a connection.
ContactStyleINTEGER { dry-contact(0), wet-contact(1) }currentDefines the different types of discrete alarm contacts.
DataBitsINTEGER { data-bits-7(7), data-bits-8(8) }currentDefines the number of data bits in a byte for serial communication.
DayOfWeekINTEGER { sunday(0), monday(1), tuesday(2), wednesday(3), thursday(4), friday(5), saturday(6) }currentDay of the week
DescriptionStringOCTET STRING (SIZE (0..80))currentA character string used for descriptions.
DigitalStateINTEGER { off(0), on(1) }currentA type with only two states, used specifically to represent the state of a digital reading.
DiscreteFormulaINTEGER { a-and-b(0), not-a-and-b(1), a-and-not-b(2), not-a-and-not-b(3), a-or-b(4), not-a-or-b(5), a-or-not-b(6), not-a-or-not-b(7), a-xor-b(8), not-a-xor-b(9), a-xor-not-b(10), not-a-xor-not-b(11) }currentDefines the type of formula used for derived discretes.
EthernetRateINTEGER { allow-100-mbps(0), force-10-mbps(1) }currentEthernet Rate
EthernetTypeINTEGER { allow-full-duplex(0), force-half-duplex(1) }currentEthernet Type
IOFormatINTEGER { single-pin(0), single-pin-with-ground(1), two-pins(2), two-pins-with-ground(3), two-pins-right-to-left(4), three-pins(5), three-pins-right-to-left(6), rj(7), onboard-built-in(8) }currentDefines the physical pin layout of slot cards.
LevelINTEGER { normal(0), critical(1), major(2), minor(3), status(4) }currentDescribes a priority or level.
MeasureStyleINTEGER { english(0), metric(1) }currentDefines state of measurement style English or Metic.
MODBUSCommandINTEGER { read-holding-register(3), read-input-register(4) }currentFunction code
OutputModeINTEGER { manual(0), automatic(1) }currentDefines the different ways a control point can be activated.
OutputStateINTEGER { open(0), closed(1) }currentDefines states for an output.
ParityINTEGER { none(0), even-parity(1), odd-parity(2) }currentDefines the parity for serial communication.
PortTypeINTEGER { not-present(0), rs-232(1), rs-485(2), dialup(3), iden(4), e2a(5), cdma(6), gps(7), edge(8), t202(9) }currentDefines the type of serial port.
ProductTypeINTEGER { webmon-edge(0), webmon-matrix(1) }currentDefines the type of device.
ProtocolINTEGER { none(0), command-line(1), modbus-interrogation(2), configuration-transfer(3), ip-switchboard(4), terminal-server(5), user-login(6), modem-mode(7), ppp-server(8), dcm-responder(9), ascii-log-single-line(10), e2a-host(11), gps-reader(12), port-redirect(13), sensor-reader(14), tl1-responder(15), dcpf-responder(16), lcd-protocol(17), tabs-responder(18), configuration-menu(19) }currentDefines different protocols used for communication.
SensorTypeINTEGER { raw(0), temperature(1), humidity(2) }currentSensor Type
SerialCTSINTEGER { cts-ignore(0), cts-require(1) }currentDefines the different CTS states for serial communication.
SerialRTSINTEGER { rts-never-on(0), rts-always-on(1), rts-on-for-transmit(2) }currentDefines the different RTS states for serial communication.
SlotIdINTEGER { empty(0), discrete-inputs(1), discrete-outputs(2), serial-ports(3), onboard-sensors(4), analog-inputs(5), switch-ports(6), sensor-inputs(7) }currentDefines the different types of slot types available.
SNMPAccessINTEGER { noauthnopriv(0), authnopriv-md5(1), authpriv-md5(2), authnopriv-sha(3), authpriv-sha(4) }currentAuth/Priv type
SNMPCommandTypeINTEGER { get(160), set(163) }currentCommand type
SNMPVarbindTypeINTEGER { integer(2), string(4) }currentValue type
SnmpVersionINTEGER { snmpv1(0), snmpv2c(1), snmpv3(2), snmpv2c-inform(3), snmpv3-inform(4) }currentDefines which version of SNMP is used for traps.
StopBitsINTEGER { stop-bit-1(1), stop-bits-2(2) }currentDefines the number of stop bits in a byte for serial communication.
TL1DirnINTEGER { blank(0), trmt(1), rcv(2), na(3) }currentDirection
TL1IssueINTEGER { issue-3(3), issue-5(5) }currentTL1 Issue
TL1LocnINTEGER { blank(0), nend(1), fend(2), line(3) }currentLocation
TL1SrveffINTEGER { blank(0), sa(1), nsa(2) }currentService Effecting
UseDialoutINTEGER { never(0), always(1), as-backup(2) }currentUse Dialout
VoltageRangeINTEGER { plus-minus-100-volts(100), sensor-port(5) }currentDefines the valid voltage ranges.