MIB Viewer

WESTERMO-LYNX-MIB

68 objects
This MIB module controls the private part for the Westermo Lynx switch.
Imported Objects
SNMPv2-CONFNOTIFICATION-GROUP OBJECT-GROUP
SNMPv2-SMIIpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE
SNMPv2-TCDisplayString
WESTERMO-OID-MIBproducts
OIDNameAccessStatusDescription
1.3.6.1.4.1.16177.1.2IdentitylynxThis MIB module controls the private part for the Westermo Lynx switch.
1.3.6.1.4.1.16177.1.2.1Nodegeneral
1.3.6.1.4.1.16177.1.2.1.1Scalartemperatureread-onlycurrentRead the temperature on the R200/T200.
1.3.6.1.4.1.16177.1.2.1.2ScalarswVersionread-onlycurrentRead the software version of the managed cpu software on the R200/T200.
1.3.6.1.4.1.16177.1.2.1.3ScalarswVersionBootLoaderread-onlycurrentRead the software version of the baseboard cpu on the R200/T200.
1.3.6.1.4.1.16177.1.2.1.4ScalarhwVersionBoardread-onlycurrentRead the hardware version of the managed cpu board on the R200/T200.
1.3.6.1.4.1.16177.1.2.1.5ScalarhwVersionPldread-onlycurrentRead the hardware version of the baseboard cpu software on the R200/T200.
1.3.6.1.4.1.16177.1.2.1.6ScalarserialNumberread-onlycurrentThe serial number for the switch.
1.3.6.1.4.1.16177.1.2.1.7ScalarbatchIDread-onlycurrentThe batch ID number for the switch.
1.3.6.1.4.1.16177.1.2.1.8ScalarhwConfigread-onlycurrentShows the Flash memory type.
1.3.6.1.4.1.16177.1.2.1.9Scalarresetread-writecurrentReset the lynx.
1.3.6.1.4.1.16177.1.2.1.10ScalarpowerSupplyread-onlycurrentRead the power supply status. The system has redundant power supply possibillites. This mib reads out the status.
1.3.6.1.4.1.16177.1.2.1.11ScalartrapHostAddr1read-writecurrentThe address to the trap host PC in the network.
1.3.6.1.4.1.16177.1.2.1.12ScalartrapHostAddr2read-writecurrentThe address to the trap host PC in the network.
1.3.6.1.4.1.16177.1.2.1.13ScalarreadPasswordread-writecurrentThe read-only community string
1.3.6.1.4.1.16177.1.2.1.14ScalarwritePasswordread-writecurrentThe read/write community string
1.3.6.1.4.1.16177.1.2.1.15GroupportGroupcurrentNetwork port properties.
1.3.6.1.4.1.16177.1.2.1.16GroupmiscGroupcurrentGeneral properties.
1.3.6.1.4.1.16177.1.2.1.17GrouptrapGroupcurrentTraps.
1.3.6.1.4.1.16177.1.2.1.18GroupigmpGroupcurrentIGMP snooping properties.
1.3.6.1.4.1.16177.1.2.2Nodeconfig
1.3.6.1.4.1.16177.1.2.2.1ScalarontPortNumberread-onlycurrentThe number of network ports.
1.3.6.1.4.1.16177.1.2.2.2TableontTablenot-accessiblecurrentA list of configuration entries. The number of entries is given by the value of ifNumber.
1.3.6.1.4.1.16177.1.2.2.2.1RowontEntrynot-accessiblecurrentAn interface entry containing objects at the subnetwork layer and below for a particular interface.
1.3.6.1.4.1.16177.1.2.2.2.1.1ColumnportIndexread-onlycurrentA unique value, greater than zero, for each port.
1.3.6.1.4.1.16177.1.2.2.2.1.2ColumnportEnableread-writecurrentEnables/disables port
1.3.6.1.4.1.16177.1.2.2.2.1.3ColumnportDuplexModeread-writecurrentDuplex mode for port
1.3.6.1.4.1.16177.1.2.2.2.1.4ColumnportAutoNegotiateread-writecurrentEnable/Disable autonegotiation for port
1.3.6.1.4.1.16177.1.2.2.2.1.5ColumnportSpeedread-writecurrentSpeed for port
1.3.6.1.4.1.16177.1.2.2.2.1.6ColumnportAlarmread-writecurrentAdd this port to be included in the STAT group.
1.3.6.1.4.1.16177.1.2.2.2.1.7ColumnportTyperead-onlycurrentShows the port type fibre or copper.
1.3.6.1.4.1.16177.1.2.2.2.1.8ColumntimeSyncFiltersread-writecurrentThis values handles the timesync filters for the port. The filters can be black, blue and red. Not working in release 2.06.
1.3.6.1.4.1.16177.1.2.2.2.1.9ColumnrstpPortTrunkread-writecurrentThis value is used to define the RSTP trunk ports. Not working in release 2.06.
1.3.6.1.4.1.16177.1.2.2.2.1.10ColumnigmpPortTrunkread-writecurrentThis value is used to define the IGMP trunk ports. Not working in release 2.06.
1.3.6.1.4.1.16177.1.2.2.2.1.12ColumnremovePortTagread-writecurrentThis value is used to define which port that will remove the vlan tag before the packets is send out. Not working in release 2.06.
1.3.6.1.4.1.16177.1.2.2.2.1.13ColumnvlanIdread-writecurrentThis value is used define the vlan id number for each vlan id. Each row represents a color: 1: white 2: red 3: blue 4: green 5: yellow 6: brown 7: pink
1.3.6.1.4.1.16177.1.2.2.2.1.14ColumnvlanPrioread-writecurrentThis value is used define the vlan priority number for each vlan id. The first vlan is the same as white vlan, vlan 2 = red vlan, vlan 3 = blue vlan, vlan 4 = …
1.3.6.1.4.1.16177.1.2.2.2.1.15ColumnportVlanColorsread-writecurrentThis value is used to give extra vlan values for this port. The values can be white, red, blue, green, brown, yellow or pink, separated by whitespace.
1.3.6.1.4.1.16177.1.2.2.2.1.16ColumnvlanDefaultColorread-writecurrentDefault VLAN color for this port.
1.3.6.1.4.1.16177.1.2.2.2.1.17ColumnigmpColorread-writecurrentIGMP port color.
1.3.6.1.4.1.16177.1.2.2.2.1.18ColumnrstpPortStatusread-writecurrentRSTP port status
1.3.6.1.4.1.16177.1.2.2.2.1.19ColumnlinkStatusread-writecurrentport link status
1.3.6.1.4.1.16177.1.2.2.3Scalarsnmpread-writecurrentEnable/disable the SNMP function.
1.3.6.1.4.1.16177.1.2.2.4Scalarfrntread-writecurrentEnable/disable the FRNTv0 function.
1.3.6.1.4.1.16177.1.2.2.5ScalarfrntPortsread-writecurrentConfigure the FRNTv0 ports. Not working in release 2.06.
1.3.6.1.4.1.16177.1.2.2.6Scalardhcpread-writecurrentEnable/disable the DHCP function.
1.3.6.1.4.1.16177.1.2.2.7ScalarenableVlanread-writecurrentSet the VLAN functions on the switch. Not working in release 2.06.
1.3.6.1.4.1.16177.1.2.2.8ScalaripAddressread-writecurrentThe IPv4 Address of the switch. This value is changed after reset.
1.3.6.1.4.1.16177.1.2.2.9ScalaripNetMaskread-writecurrentThe IPv4 Subnet mask of the switch. This value is changed after reset.
1.3.6.1.4.1.16177.1.2.2.10ScalardefaultGatewayread-writecurrentAddress of the switch default gateway. This value is changed after reset.
1.3.6.1.4.1.16177.1.2.2.11ScalardhcpRelayAgentread-writecurrentEnable/disable the DHCP Relay Agent function.
1.3.6.1.4.1.16177.1.2.2.12ScalardhcpRelayAgentServer1read-writecurrentThe DHCP Relay Agents Primary DHCP Server
1.3.6.1.4.1.16177.1.2.2.13ScalardhcpRelayAgentServer2read-writecurrentThe DHCP Relay Agents Secondary DHCP Server
1.3.6.1.4.1.16177.1.2.2.14Scalarrstpread-writecurrentEnable/disable RSTP / STP.
1.3.6.1.4.1.16177.1.2.5Nodeigmp
1.3.6.1.4.1.16177.1.2.5.1Scalarsnoopingread-writecurrentEnable/disable IGMP snooping.
1.3.6.1.4.1.16177.1.2.5.2Scalarautomoderead-writecurrentIGMP Snooping Automode
1.3.6.1.4.1.16177.1.2.5.3Scalarquerierread-writecurrentIGMP Querier
1.3.6.1.4.1.16177.1.2.5.4Scalarstopfilterread-writecurrentMulticast stop filter.
1.3.6.1.4.1.16177.1.2.5.6Scalarquerytimeoutread-writecurrentIGMP Query timeout.
1.3.6.1.4.1.16177.1.2.6Nodestat
1.3.6.1.4.1.16177.1.2.6.1ScalarstatusCoderead-onlycurrentRead out a summary from the status code from the status registers. Any error in port alarms masked against port link status, DC relays or frnt will return 2.
1.3.6.1.4.1.16177.1.2.6.2ScalarenableStatusTrapread-writecurrentEnable or disable status relay trap message.
1.3.6.1.4.1.16177.1.2.7NodeprivTraps
1.3.6.1.4.1.16177.1.2.7.1NotificationstatWarningcurrentStatus warning.
1.3.6.1.4.1.16177.1.2.7.2NotificationstatNoWarningcurrentStatus warning.
1.3.6.1.4.1.16177.1.2.7.3NotificationlinkUpChangeWarningcurrentLink up notification.
1.3.6.1.4.1.16177.1.2.7.4NotificationlinkDownChangeWarningcurrentLink down notification.