WISI-GTSENSORS-MIB
52 objects
This MIB module represents the various sensors that are installed in a system or standalone unit, such as temperature sensors, power supply voltage/current measurements and fan RPM sensors.
Imported Objects
| SNMPv2-CONF | MODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP |
| SNMPv2-SMI | Counter32 Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DisplayString |
| WISI-GTMODULES-MIB | gtModule |
| WISI-TANGRAM-MIB | gtUnit |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.7465.20.2.9.1.3 | IdentitygtSensorsMIB | This MIB module represents the various sensors that are installed in a system or standalone unit, such as temperature sensors, power supply voltage/current mea… | ||
| 1.3.6.1.4.1.7465.20.2.9.1.3.0 | NodegtSensorsNotifications | |||
| 1.3.6.1.4.1.7465.20.2.9.1.3.0.1 | NotificationgtSensorsNotifyFanPlugin | current | The gtSensorsNotifyFanPlugin notification indicates that a new fan unit has been plugged-in. | |
| 1.3.6.1.4.1.7465.20.2.9.1.3.0.2 | NotificationgtSensorsNotifyFanPlugout | current | The gtSensorsNotifyFanPlugout notification indicates that a fan unit has been plugged-out. | |
| 1.3.6.1.4.1.7465.20.2.9.1.3.0.3 | NotificationgtSensorsNotifyPSUPlugin | current | The gtSensorsNotifyPSUPlugin notification indicates that a new PSU (Power Supply Unit) has been plugged-in. | |
| 1.3.6.1.4.1.7465.20.2.9.1.3.0.4 | NotificationgtSensorsNotifyPSUPlugout | current | The gtSensorsNotifyPSUPlugout notification indicates that a PSU (Power Supply Unit) has been plugged-out. | |
| 1.3.6.1.4.1.7465.20.2.9.1.3.0.5 | NotificationgtSensorsNotifyTemperature | current | The gtSensorsNotifyTemperature notification indicates that temperature on GT11 board is above upper limit. | |
| 1.3.6.1.4.1.7465.20.2.9.1.3.0.6 | NotificationgtSensorsNotifyFanSpeed | current | The gtSensorsNotifyFanSpeed notification indicates that at least one of the fans RPM on fanbay is below lower limit. | |
| 1.3.6.1.4.1.7465.20.2.9.1.3.0.7 | NotificationgtSensorsNotifyPSUCurrent | current | The gtSensorsNotifyPSUCurrent notification indicates that a PSU (Power Supply Unit) output current is out of range limit. | |
| 1.3.6.1.4.1.7465.20.2.9.1.3.0.8 | NotificationgtSensorsNotifyPSUVoltage | current | The gtSensorsNotifyPSUVoltage notification indicates that a PSU (Power Supply Unit) output voltage is out of range limit. | |
| 1.3.6.1.4.1.7465.20.2.9.1.3.0.9 | NotificationgtSensorsNotifyPSUTemperature | current | The gtSensorsNotifyPSUTemperature notification indicates that a PSU (Power Supply Unit) temperature is above upper limit. | |
| 1.3.6.1.4.1.7465.20.2.9.1.3.0.10 | NotificationgtSensorsNotifyPSUTemperatureClear | current | The gtSensorsNotifyPSUTempHighClear notification indicates that a PSU (Power Supply Unit) temperature has decreased below upper limit. | |
| 1.3.6.1.4.1.7465.20.2.9.1.3.0.11 | NotificationgtSensorsNotifyBOARDTemperatureClear | current | The gtSensorsNotifyBOARDTempHighClear notification indicates that temperature on GT11 board has decreased below upper limit | |
| 1.3.6.1.4.1.7465.20.2.9.1.3.0.12 | NotificationgtSensorsNotifyPSUFailure | current | The gtSensorsNotifyPSUFailure notification indicates that a PSU (Power Supply Unit) internal voltage dropped below limit. | |
| 1.3.6.1.4.1.7465.20.2.9.1.3.0.13 | NotificationgtSensorsNotifyPSUFailureClear | current | The gtSensorsNotifyPSUFailureClear notification indicates that a PSU (Power Supply Unit) internal voltage has increased above lower limit. | |
| 1.3.6.1.4.1.7465.20.2.9.1.3.1 | NodegtSensorsObjects | |||
| 1.3.6.1.4.1.7465.20.2.9.1.3.1.1 | ScalargtNumTemps | read-only | current | The gtNumTemps entity represents the number of temperature sensors within the GT01/GN50 rack unit. The related entries are provided by gtTempsTable. |
| 1.3.6.1.4.1.7465.20.2.9.1.3.1.2 | TablegtTempsTable | not-accessible | current | The gtTempsTable table contains a list of all temperature sensors within the GT01/GN50 rack unit. The number of entries is provided by gtNumTemps. |
| 1.3.6.1.4.1.7465.20.2.9.1.3.1.2.1 | RowgtTempsEntry | not-accessible | current | The gtTempsEntry table entry represents a temperature sensors within the GT01/GN50 rack unit. The number of entries is provided by gtNumTemps. |
| 1.3.6.1.4.1.7465.20.2.9.1.3.1.2.1.1 | ColumngtTemp | not-accessible | current | The gtTemp entity represents the numeric index of a temperature sensors within the GT01/GN50 rack unit. |
| 1.3.6.1.4.1.7465.20.2.9.1.3.1.2.1.2 | ColumngtTempName | read-only | current | The gtTempName entity represents the symbolic name of a temperature sensors within the GT01/GN50 rack unit. |
| 1.3.6.1.4.1.7465.20.2.9.1.3.1.2.1.3 | ColumngtTempValue | read-only | current | The gtTempValue entity represents the measured value of a temperature sensors within the GT01/GN50 rack unit. |
| 1.3.6.1.4.1.7465.20.2.9.1.3.1.3 | ScalargtNumFans | read-only | current | The gtNumFans entity represents the number of cooling fans within the GT01/GN50 rack unit. The related entries are provided by gtFansTable. |
| 1.3.6.1.4.1.7465.20.2.9.1.3.1.4 | TablegtFansTable | not-accessible | current | The gtFansTable table contains a list of all cooling fans within the GT01/GN50 rack unit. The number of entries is provided by gtNumFans. |
| 1.3.6.1.4.1.7465.20.2.9.1.3.1.4.1 | RowgtFansEntry | not-accessible | current | The gtFansEntry table entry represents an cooling fan within the GT01/GN50 rack unit. The number of entries is provided by gtNumFans. |
| 1.3.6.1.4.1.7465.20.2.9.1.3.1.4.1.1 | ColumngtFan | not-accessible | current | The gtFan entity represents the numeric index of a cooling fan within the GT01/GN50 rack unit. |
| 1.3.6.1.4.1.7465.20.2.9.1.3.1.4.1.2 | ColumngtFanName | read-only | current | The gtFanName entity represents the symbolic name of a cooling fan within the GT01/GN50 rack unit. |
| 1.3.6.1.4.1.7465.20.2.9.1.3.1.4.1.3 | ColumngtFanControl | read-only | current | The gtFanControl entity represents the RPM setting of a cooling fan within the GT01/GN50 rack unit. |
| 1.3.6.1.4.1.7465.20.2.9.1.3.1.4.1.4 | ColumngtFanSpeed | read-only | current | The gtFanSpeed entity represents the revolutions per minute of a cooling fan within the GT01/GN50 rack unit. |
| 1.3.6.1.4.1.7465.20.2.9.1.3.1.4.1.5 | ColumngtFanUptime | read-only | current | The gtFanUptime entity represents the current uptime of a cooling fan within the GT01/GN50 rack unit. |
| 1.3.6.1.4.1.7465.20.2.9.1.3.1.4.1.6 | ColumngtFanLifetime | read-only | current | The gtFanLifetime entity represents the accumulated lifetime of a cooling fan within the GT01/GN50 rack unit. |
| 1.3.6.1.4.1.7465.20.2.9.1.3.1.5 | ScalargtNumPSUs | read-only | current | The gtNumPSUs entity represents the number of power supply units within the GT01/GN50 rack unit. The related entries are provided by gtPSUsTable. |
| 1.3.6.1.4.1.7465.20.2.9.1.3.1.6 | TablegtPSUsTable | not-accessible | current | The gtPSUsTable table contains a list of all power supply units within the GT01/GN50 rack unit. The number of entries is provided by gtNumPSUs. |
| 1.3.6.1.4.1.7465.20.2.9.1.3.1.6.1 | RowgtPSUsEntry | not-accessible | current | The gtPSUsEntry table entry represents a power supply unit within the GT01/GN50 rack unit. The number of entries is provided by gtNumPSUs. |
| 1.3.6.1.4.1.7465.20.2.9.1.3.1.6.1.1 | ColumngtPSU | not-accessible | current | The gtPSU entity represents the numeric index of a power supply unit within the GT01/GN50 rack unit. |
| 1.3.6.1.4.1.7465.20.2.9.1.3.1.6.1.2 | ColumngtPSUName | read-only | current | The gtPSUName entity represents the symbolic name of a power supply unit within the GT01/GN50 rack unit. |
| 1.3.6.1.4.1.7465.20.2.9.1.3.1.6.1.3 | ColumngtPSUPower | read-only | current | The gtPSUPower entity represents the maximum output of a power supply unit within the GT01/GN50 rack unit. |
| 1.3.6.1.4.1.7465.20.2.9.1.3.1.6.1.4 | ColumngtPSUCurrent | read-only | current | The gtPSUCurrent entity represents the output current of a power supply unit within the GT01/GN50 rack unit. |
| 1.3.6.1.4.1.7465.20.2.9.1.3.1.6.1.5 | ColumngtPSUVoltageInt | read-only | current | The gtPSUVoltageInt entity represents the internal voltage of a power supply unit within the GT01/GN50 rack unit. |
| 1.3.6.1.4.1.7465.20.2.9.1.3.1.6.1.6 | ColumngtPSUVoltageOR | read-only | current | The gtPSUVoltageOR entity represents the OR voltage drop of a power supply unit within the GT01/GN50 rack unit. |
| 1.3.6.1.4.1.7465.20.2.9.1.3.1.6.1.7 | ColumngtPSUVoltageExt | read-only | current | The gtPSUVoltageExt entity represents the external voltage of a power supply unit within the GT01/GN50 rack unit. |
| 1.3.6.1.4.1.7465.20.2.9.1.3.1.6.1.8 | ColumngtPSUTemperature | read-only | current | The gtPSUTemperature entity represents the temperature of a power supply unit within the GT01/GN50 rack unit. |
| 1.3.6.1.4.1.7465.20.2.9.1.3.2 | NodegtSensorsConformance | |||
| 1.3.6.1.4.1.7465.20.2.9.1.3.2.1 | NodegtSensorsCompliances | |||
| 1.3.6.1.4.1.7465.20.2.9.1.3.2.1.1 | CompliancegtSensorsMIBCompliance | current | The compliance statement for GTSENSORSv2 entities which implement the GTSENSORSv2 MIB. | |
| 1.3.6.1.4.1.7465.20.2.9.1.3.2.2 | NodegtSensorsGroups | |||
| 1.3.6.1.4.1.7465.20.2.9.1.3.2.2.1 | GroupgtSensorsV1Group | current | The gtSensorsV1Group group is mandatory only for those GTSENSORSv2 entities which also implement GTSENSORSv1. | |
| 1.3.6.1.4.1.7465.20.2.9.1.3.2.2.2 | GroupgtSensorsSystemGroup | current | The gtSensorsSystemGroup group defines GTSENSORSv2 entities which are mandatory. | |
| 1.3.6.1.4.1.7465.20.2.9.1.3.2.2.3 | GroupgtSensorsStatsGroup | current | The gtSensorsStatsGroup group defines GTSENSORSv2 entities which provide statistical information. | |
| 1.3.6.1.4.1.7465.20.2.9.1.3.2.2.4 | GroupgtSensorsTrapGroup | current | The gtSensorsTrapGroup group defines GTSENSORSv2 trap objects which are mandatory. | |
| 1.3.6.1.4.1.7465.20.2.9.1.3.2.2.5 | GroupgtSensorsSetGroup | current | The gtSensorsSetGroup group defines GTSENSORSv2 entities which can be set the manager. | |
| 1.3.6.1.4.1.7465.20.2.9.1.3.2.2.6 | GroupgtSensorsBasicNotificationsGroup | current | The gtSensorsBasicNotificationsGroup group defines GTSENSORSv2 notification objects which are mandatory. |