WebGraph-AnalogIO-57761-US-MIB
292 objects
No module-level DESCRIPTION found.
Imported Objects
| RFC-1212 | OBJECT-TYPE |
| RFC-1215 | TRAP-TYPE |
| RFC1155-SMI | enterprises IpAddress NetworkAddress TimeTicks |
| RFC1213-MIB | DisplayString PhysAddress |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.5040 | Nodewut | |||
| 1.3.6.1.4.1.5040.1 | NodewtComServer | |||
| 1.3.6.1.4.1.5040.1.2 | NodewtWebio | |||
| 1.3.6.1.4.1.5040.1.2.28 | NodewtWebGraphAnalog57761 | |||
| 1.3.6.1.4.1.5040.1.2.28.1 | NodewtWebGraphAnalog57761Inventory | |||
| 1.3.6.1.4.1.5040.1.2.28.1.1 | ScalarwtWebGraphAnalog57761Sensors | read-only | mandatory | Number of sensors |
| 1.3.6.1.4.1.5040.1.2.28.1.2 | TablewtWebGraphAnalog57761SensorTable | not-accessible | mandatory | List of sensors. |
| 1.3.6.1.4.1.5040.1.2.28.1.2.1 | RowwtWebGraphAnalog57761SensorEntry | not-accessible | mandatory | List of sensor numbers. |
| 1.3.6.1.4.1.5040.1.2.28.1.2.1.1 | ColumnwtWebGraphAnalog57761SensorNo | read-only | mandatory | Sensor number. |
| 1.3.6.1.4.1.5040.1.2.28.1.3 | TablewtWebGraphAnalog57761ValuesTable | not-accessible | mandatory | List of measurement values corresponding to the channel numbers. |
| 1.3.6.1.4.1.5040.1.2.28.1.3.1 | RowwtWebGraphAnalog57761ValuesEntry | not-accessible | mandatory | Measurement values of the sensors. |
| 1.3.6.1.4.1.5040.1.2.28.1.3.1.1 | ColumnwtWebGraphAnalog57761Values | read-write | mandatory | Measurement value of the sensor, ASCII. This value will be translated according to the ports settings for the read and write operations. |
| 1.3.6.1.4.1.5040.1.2.28.1.4 | TablewtWebGraphAnalog57761BinaryValuesTable | not-accessible | mandatory | List of binary measurement values corresponding to the channel numbers. |
| 1.3.6.1.4.1.5040.1.2.28.1.4.1 | RowwtWebGraphAnalog57761BinaryValuesEntry | not-accessible | mandatory | Binary measurement values of the sensors. |
| 1.3.6.1.4.1.5040.1.2.28.1.4.1.1 | ColumnwtWebGraphAnalog57761BinaryValues | read-write | mandatory | Binary measurement value of the sensor in 1/1000, signed number, 0x7FFFFFFF indicates an invalid value. This value will be translated according to the ports se… |
| 1.3.6.1.4.1.5040.1.2.28.1.8 | TablewtWebGraphAnalog57761ValuesPointTable | not-accessible | mandatory | List of measurement values corresponding to the channel numbers. |
| 1.3.6.1.4.1.5040.1.2.28.1.8.1 | RowwtWebGraphAnalog57761ValuesPointEntry | not-accessible | mandatory | Measurement values of the sensors. |
| 1.3.6.1.4.1.5040.1.2.28.1.8.1.1 | ColumnwtWebGraphAnalog57761ValuesPoint | read-write | mandatory | Measurement value of the sensor, ASCII. This value will be translated according to the ports settings for the read and write operations. |
| 1.3.6.1.4.1.5040.1.2.28.2 | NodewtWebGraphAnalog57761SessCntrl | |||
| 1.3.6.1.4.1.5040.1.2.28.2.1 | ScalarwtWebGraphAnalog57761SessCntrlPassword | read-write | mandatory | Entering this password opens a session which is ended by writing a 1 to wtWebGraphAnalog57761SessCntrlLogout. When read this variable provides a string of leng… |
| 1.3.6.1.4.1.5040.1.2.28.2.2 | ScalarwtWebGraphAnalog57761SessCntrlConfigMode | read-only | mandatory | When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is… |
| 1.3.6.1.4.1.5040.1.2.28.2.3 | ScalarwtWebGraphAnalog57761SessCntrlLogout | read-write | mandatory | If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters ar… |
| 1.3.6.1.4.1.5040.1.2.28.2.4 | ScalarwtWebGraphAnalog57761SessCntrlAdminPassword | read-write | mandatory | This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid p… |
| 1.3.6.1.4.1.5040.1.2.28.2.5 | ScalarwtWebGraphAnalog57761SessCntrlConfigPassword | read-write | mandatory | This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was ass… |
| 1.3.6.1.4.1.5040.1.2.28.3 | NodewtWebGraphAnalog57761Config | |||
| 1.3.6.1.4.1.5040.1.2.28.3.1 | NodewtWebGraphAnalog57761Device | |||
| 1.3.6.1.4.1.5040.1.2.28.3.1.1 | NodewtWebGraphAnalog57761Text | |||
| 1.3.6.1.4.1.5040.1.2.28.3.1.1.1 | ScalarwtWebGraphAnalog57761DeviceName | read-write | mandatory | Name of the Webio, which is user definable. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.1.2 | ScalarwtWebGraphAnalog57761DeviceText | read-write | mandatory | Description of the Webio, which is user definable. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.1.3 | ScalarwtWebGraphAnalog57761DeviceLocation | read-write | mandatory | Description of the location of the Webio, which is user definable. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.1.4 | ScalarwtWebGraphAnalog57761DeviceContact | read-write | mandatory | Contact address of the system operator of the Webio, which is user definable. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.2 | NodewtWebGraphAnalog57761TimeDate | |||
| 1.3.6.1.4.1.5040.1.2.28.3.1.2.1 | NodewtWebGraphAnalog57761TimeZone | |||
| 1.3.6.1.4.1.5040.1.2.28.3.1.2.1.1 | ScalarwtWebGraphAnalog57761TzOffsetHrs | read-write | mandatory | Offset hours for the time zone (winter time) with respect to UTC. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.2.1.2 | ScalarwtWebGraphAnalog57761TzOffsetMin | read-write | mandatory | Offset minutes for the time zone (winter time) with respect to UTC. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.2.1.3 | ScalarwtWebGraphAnalog57761TzEnable | read-write | mandatory | Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone |
| 1.3.6.1.4.1.5040.1.2.28.3.1.2.1.4 | ScalarwtWebGraphAnalog57761StTzOffsetHrs | read-write | mandatory | Offset hours of the time zone (summer time) with respect to UTC. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.2.1.5 | ScalarwtWebGraphAnalog57761StTzOffsetMin | read-write | mandatory | Offset minutes of the time zone (summer time) with respect to UTC. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.2.1.6 | ScalarwtWebGraphAnalog57761StTzEnable | read-write | mandatory | Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime |
| 1.3.6.1.4.1.5040.1.2.28.3.1.2.1.7 | ScalarwtWebGraphAnalog57761StTzStartMonth | read-write | mandatory | Month in which the change is made from winter time to summer time. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.2.1.8 | ScalarwtWebGraphAnalog57761StTzStartMode | read-write | mandatory | Mode of the day of the week for which the change is made from winter time to summer time. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.2.1.9 | ScalarwtWebGraphAnalog57761StTzStartWday | read-write | mandatory | Day of the week on which the change is made from winter time to summer time |
| 1.3.6.1.4.1.5040.1.2.28.3.1.2.1.10 | ScalarwtWebGraphAnalog57761StTzStartHrs | read-write | mandatory | Hour in which the time zone is changed from winter to summer time with respect to UTC. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.2.1.11 | ScalarwtWebGraphAnalog57761StTzStartMin | read-write | mandatory | Minute in which the time zone is changed from winter to summer time with respect to UTC. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.2.1.12 | ScalarwtWebGraphAnalog57761StTzStopMonth | read-write | mandatory | Month in which the change is made from summer time to winter time. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.2.1.13 | ScalarwtWebGraphAnalog57761StTzStopMode | read-write | mandatory | Mode of the week day on which the change is made from summer time to winter time. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.2.1.14 | ScalarwtWebGraphAnalog57761StTzStopWday | read-write | mandatory | Day of the week on which the change is made from summer time to winter time. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.2.1.15 | ScalarwtWebGraphAnalog57761StTzStopHrs | read-write | mandatory | Hour at which the time zone is changed from summer to winter time with respect to UTC. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.2.1.16 | ScalarwtWebGraphAnalog57761StTzStopMin | read-write | mandatory | Minute at which the time zone is changed from summer to winter time with respect to UTC. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.2.2 | NodewtWebGraphAnalog57761TimeServer | |||
| 1.3.6.1.4.1.5040.1.2.28.3.1.2.2.1 | ScalarwtWebGraphAnalog57761TimeServer1 | read-write | mandatory | IP address or name of the 1st time server in ASCII |
| 1.3.6.1.4.1.5040.1.2.28.3.1.2.2.2 | ScalarwtWebGraphAnalog57761TimeServer2 | read-write | mandatory | IP address or name of the 2nd time server in ASCII |
| 1.3.6.1.4.1.5040.1.2.28.3.1.2.2.3 | ScalarwtWebGraphAnalog57761TsEnable | read-write | mandatory | Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server |
| 1.3.6.1.4.1.5040.1.2.28.3.1.2.2.4 | ScalarwtWebGraphAnalog57761TsSyncTime | read-write | mandatory | Daily synchronisation time with the time server (hour: 0-23). |
| 1.3.6.1.4.1.5040.1.2.28.3.1.2.3 | NodewtWebGraphAnalog57761DeviceClock | |||
| 1.3.6.1.4.1.5040.1.2.28.3.1.2.3.1 | ScalarwtWebGraphAnalog57761ClockHrs | read-write | mandatory | Clock hours taking into account the time zone settings. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.2.3.2 | ScalarwtWebGraphAnalog57761ClockMin | read-write | mandatory | Clock minutes taking into account the time zone settings. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.2.3.3 | ScalarwtWebGraphAnalog57761ClockDay | read-write | mandatory | Date: Day of the month, taking into account the time zone settings. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.2.3.4 | ScalarwtWebGraphAnalog57761ClockMonth | read-write | mandatory | Date: Month, taking into account the time zone settings. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.2.3.5 | ScalarwtWebGraphAnalog57761ClockYear | read-write | mandatory | Date: Year, taking into account the time zone settings. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3 | NodewtWebGraphAnalog57761Basic | |||
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.1 | NodewtWebGraphAnalog57761Network | |||
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.1.1 | ScalarwtWebGraphAnalog57761IpAddress | read-write | mandatory | IP address of the Webio |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.1.2 | ScalarwtWebGraphAnalog57761SubnetMask | read-write | mandatory | Subnet mask of the Webio |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.1.3 | ScalarwtWebGraphAnalog57761Gateway | read-write | mandatory | Gateway of the Webio |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.1.4 | ScalarwtWebGraphAnalog57761DnsServer1 | read-write | mandatory | IP address of the 1st DNS server in ASCII |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.1.5 | ScalarwtWebGraphAnalog57761DnsServer2 | read-write | mandatory | IP address of the 2nd DNS server in ASCII |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.1.6 | ScalarwtWebGraphAnalog57761AddConfig | read-write | mandatory | Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: DHCP disable Bit 0: BOOTP disable |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.2 | NodewtWebGraphAnalog57761HTTP | |||
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.2.1 | ScalarwtWebGraphAnalog57761Startup | read-write | mandatory | Binary coded start page: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: Index.htm Bit 2: Home.htm Bit 3: User.htm Only one page may be selecte… |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.2.2 | ScalarwtWebGraphAnalog57761GetHeaderEnable | read-write | mandatory | If these bits are set, every answer of a short form GET question will be lead by the IP-address and name of the device and/or a HTTP header: Octet 1: unused Oc… |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.2.3 | ScalarwtWebGraphAnalog57761HttpPort | read-write | mandatory | Definition of the standard HTML port (Default: 80). |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.3 | NodewtWebGraphAnalog57761Mail | |||
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.3.1 | ScalarwtWebGraphAnalog57761MailAdName | read-write | mandatory | Device name for mail administration. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.3.2 | ScalarwtWebGraphAnalog57761MailReply | read-write | mandatory | Reply address for the mail server. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.3.3 | ScalarwtWebGraphAnalog57761MailServer | read-write | mandatory | Name or IP address of the mail server. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.3.4 | ScalarwtWebioAn1MailEnable | read-write | mandatory | Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.3.5 | ScalarwtWebGraphAnalog57761MailAuthentication | read-write | mandatory | Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: u… |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.3.6 | ScalarwtWebGraphAnalog57761MailAuthUser | read-write | mandatory | Name of the user to be authenticated. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.3.7 | ScalarwtWebGraphAnalog57761MailAuthPassword | read-write | mandatory | Authentication password. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.3.8 | ScalarwtWebGraphAnalog57761MailPop3Server | read-write | mandatory | Name or Ip-address of the POP3 Servers. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.4 | NodewtWebGraphAnalog57761SNMP | |||
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.4.1 | ScalarwtWebGraphAnalog57761SnmpCommunityStringRead | read-write | mandatory | Community string read only |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.4.2 | ScalarwtWebGraphAnalog57761SnmpCommunityStringReadWrite | read-write | mandatory | Community string read / write |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.4.3 | ScalarwtWebGraphAnalog57761SystemTrapManagerIP | read-write | mandatory | Name or IP address of the TCP server which accepts the system trap. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.4.4 | ScalarwtWebGraphAnalog57761SystemTrapEnable | read-write | mandatory | Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2-7: unused |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.4.5 | ScalarwtWebGraphAnalog57761SnmpEnable | read-write | mandatory | Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compare… |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.4.6 | ScalarwtWebGraphAnalog57761SnmpCommunityStringTrap | read-write | mandatory | Community string send within traps. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.4.7 | ScalarwtWebGraphAnalog57761SnmpSystemTrapManagerPort | read-write | mandatory | Port number of the TCP server which accepts the system trap. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.5 | NodewtWebGraphAnalog57761UDP | |||
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.5.1 | ScalarwtWebGraphAnalog57761UdpPort | read-write | mandatory | Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.5.2 | ScalarwtWebGraphAnalog57761UdpEnable | read-write | mandatory | Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.6 | NodewtWebGraphAnalog57761Syslog | |||
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.6.1 | ScalarwtWebGraphAnalog57761SyslogServerIP | read-write | mandatory | Name or IP address of the Syslog server, which accepts the Syslog messgaes. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.6.2 | ScalarwtWebGraphAnalog57761SyslogServerPort | read-write | mandatory | Portnumber of the Syslog servers, default 514. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.6.3 | ScalarwtWebGraphAnalog57761SyslogSystemMessagesEnable | read-write | mandatory | Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.6.4 | ScalarwtWebGraphAnalog57761SyslogEnable | read-write | mandatory | Set bit 0to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.7 | NodewtWebGraphAnalog57761FTP | |||
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.7.1 | ScalarwtWebGraphAnalog57761FTPServerIP | read-write | mandatory | Name or IP address of the FTP server, which accepts the FTP messages. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.7.2 | ScalarwtWebGraphAnalog57761FTPServerControlPort | read-write | mandatory | Portnumber of the control port of the FTP server, default 21. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.7.3 | ScalarwtWebGraphAnalog57761FTPUserName | read-write | mandatory | FTP Loggin: user name. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.7.4 | ScalarwtWebGraphAnalog57761FTPPassword | read-write | mandatory | FTP Loggin: user password. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.7.5 | ScalarwtWebGraphAnalog57761FTPAccount | read-write | mandatory | FTP Loggin: name of account. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.7.6 | ScalarwtWebGraphAnalog57761FTPOption | read-write | mandatory | Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit … |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.7.7 | ScalarwtWebGraphAnalog57761FTPEnable | read-write | mandatory | Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.8 | NodewtWebGraphAnalog57761Language | |||
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.8.1 | ScalarwtWebGraphAnalog57761LanguageSelect | read-write | mandatory | Language selection: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2-7: unused Bit 1 : English Bit 0 : German |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.9 | NodewtWebGraphAnalog57761Binary | |||
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.9.1 | ScalarwtWebGraphAnalog57761BinaryModeCount | read-only | mandatory | Number of independent binary channels. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.9.2 | TablewtWebGraphAnalog57761BinaryIfTable | not-accessible | mandatory | Table of indices. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.9.2.1 | RowwtWebGraphAnalog57761BinaryIfEntry | not-accessible | mandatory | Indices of the binary channels. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.9.2.1.1 | ColumnwtWebGraphAnalog57761BinaryModeNo | read-only | mandatory | Number of the binary channel. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3 | TablewtWebGraphAnalog57761BinaryTable | not-accessible | mandatory | Table of properties of the binary mode. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1 | RowwtWebGraphAnalog57761BinaryEntry | not-accessible | mandatory | Binary properties. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.1 | ColumnwtWebGraphAnalog57761BinaryOperationMode | read-write | mandatory | Selection of the operation mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: … |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.2 | ColumnwtWebGraphAnalog57761BinaryTcpServerLocalPort | read-write | mandatory | Local TCP port for data exchange in this server mode. This port number must be unique within the device. Reserved port number must not be used (refere to the m… |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.3 | ColumnwtWebGraphAnalog57761BinaryTcpServerInputTrigger | read-write | mandatory | Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rul… |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.4 | ColumnwtWebGraphAnalog57761BinaryTcpServerApplicationMode | read-write | mandatory | Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4… |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.5 | ColumnwtWebGraphAnalog57761BinaryTcpClientLocalPort | read-write | mandatory | Local TCP port for data exchange in this client mode. This port number must be unique within the device. Reserved port number must not be used (refere to the m… |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.6 | ColumnwtWebGraphAnalog57761BinaryTcpClientServerPort | read-write | mandatory | Port number of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting t… |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.7 | ColumnwtWebGraphAnalog57761BinaryTcpClientServerIpAddr | read-write | mandatory | Ip address of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting th… |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.8 | ColumnwtWebGraphAnalog57761BinaryTcpClientServerPassword | read-write | mandatory | Building a connection may be protected by the administrator password of the server. Enter the server password to establish the connection, if a server administ… |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.9 | ColumnwtWebGraphAnalog57761BinaryTcpClientInactivity | read-write | mandatory | Connection timeout in 100ms. If no data are exchanged within the specified time, the device closes the connection to the server. The value 0 deactivates the ti… |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.10 | ColumnwtWebGraphAnalog57761BinaryTcpClientInputTrigger | read-write | mandatory | Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rul… |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.11 | ColumnwtWebGraphAnalog57761BinaryTcpClientInterval | read-write | mandatory | Configurable interval with a 100ms base, in which the Webio device sends data to the configured application. A interval of zero stopps the periodical sending. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.12 | ColumnwtWebGraphAnalog57761BinaryTcpClientApplicationMode | read-write | mandatory | Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4… |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.13 | ColumnwtWebGraphAnalog57761BinaryUdpPeerLocalPort | read-write | mandatory | Local UDP port for data exchange in this peer to peer mode. This port number must be unique within the device. Reserved port number must not be used (refere to… |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.14 | ColumnwtWebGraphAnalog57761BinaryUdpPeerRemotePort | read-write | mandatory | Port number of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when se… |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.15 | ColumnwtWebGraphAnalog57761BinaryUdpPeerRemoteIpAddr | read-write | mandatory | Ip address of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when set… |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.16 | ColumnwtWebGraphAnalog57761BinaryUdpPeerInputTrigger | read-write | mandatory | Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rul… |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.17 | ColumnwtWebGraphAnalog57761BinaryUdpPeerInterval | read-write | mandatory | Configurable interval with a 100ms base, in which the Webio device sends data to the configured remote device. A interval of zero stopps the periodical sending. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.18 | ColumnwtWebGraphAnalog57761BinaryUdpPeerApplicationMode | read-write | mandatory | Selection of the application mode: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unus… |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.19 | ColumnwtWebGraphAnalog57761BinaryConnectedPort | read-only | mandatory | Port number of the remote device, after connection has been established. In case of no connection or missing port informations a zero will be read. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.20 | ColumnwtWebGraphAnalog57761BinaryConnectedIpAddr | read-only | mandatory | IP address of the remote device, after connection has been established. In case of no connection or missing port informations 0.0.0.0 will be read. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.21 | ColumnwtWebGraphAnalog57761BinaryTcpServerClientHttpPort | read-write | mandatory | HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs status informations will be send to this port. Not used at mode Compatible … |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.22 | ColumnwtWebGraphAnalog57761BinaryTcpClientServerHttpPort | read-write | mandatory | HTTP port number of the remote device at TCP Client Mode. In the operating mode Box2Box connection status informations will be exchanged through this port. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.23 | ColumnwtWebGraphAnalog57761BinaryTcpServerHysteresis1 | read-write | mandatory | A change greater than this value initiate a transmission of the corresponding input value. The input 1 must be selected at wtWebGraphAnalog57761BinaryTcpServer… |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.24 | ColumnwtWebGraphAnalog57761BinaryTcpServerHysteresis2 | read-write | mandatory | A change greater than this value initiate a transmission of the corresponding input value. The input 2 must be selected at wtWebGraphAnalog57761BinaryTcpServer… |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.25 | ColumnwtWebGraphAnalog57761BinaryTcpClientHysteresis1 | read-write | mandatory | A change greater than this value initiate a transmission of the corresponding input value. The input 1 must be selected at wtWebGraphAnalog57761BinaryTcpClient… |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.26 | ColumnwtWebGraphAnalog57761BinaryTcpClientHysteresis2 | read-write | mandatory | A change greater than this value initiate a transmission of the corresponding input value. The input 2 must be selected at wtWebGraphAnalog57761BinaryTcpClient… |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.27 | ColumnwtWebGraphAnalog57761BinaryUdpPeerHysteresis1 | read-write | mandatory | A change greater than this value initiate a transmission of the corresponding input value. The input 1 must be selected at wtWebGraphAnalog57761BinaryUdpPeerIn… |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.28 | ColumnwtWebGraphAnalog57761BinaryUdpPeerHysteresis2 | read-write | mandatory | A change greater than this value initiate a transmission of the corresponding input value. The input 2 must be selected at wtWebGraphAnalog57761BinaryUdpPeerIn… |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.29 | ColumnwtWebGraphAnalog57761BinaryTcpClientServerUserName | read-write | mandatory | Building a connection may be protected by a specific user name within the server. Enter the user name to establish the connection, if a user name entry exists. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.12 | NodewtWebGraphAnalog57761MQTT | |||
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.12.1 | ScalarwtWebGraphAnalog57761MQTTEnable | read-write | mandatory | Bit 7 schaltet MQTT frei: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0-6: ungenutzt Bit 7 : MQTT enable |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.12.2 | ScalarwtWebGraphAnalog57761MQTTBrockerIP | read-write | mandatory | Name or IP-address of the MQTT-Server. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.12.3 | ScalarwtWebGraphAnalog57761MQTTUserName | read-write | mandatory | MQTT login user name. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.12.4 | ScalarwtWebGraphAnalog57761MQTTPassword | read-write | mandatory | MQTT login password. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.12.5 | ScalarwtWebGraphAnalog57761MQTTLocalPort | read-write | mandatory | Local port number. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.12.6 | ScalarwtWebGraphAnalog57761MQTTBrokerServerPort | read-write | mandatory | MQTT Server port number. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.12.7 | ScalarwtWebGraphAnalog57761MQTTInterval | read-write | mandatory | Ping intervall, if no data has to be send: time in seconds. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.12.8 | ScalarwtWebGraphAnalog57761MQTTLastWillEnable | read-write | mandatory | Bit 0 activate MQTT LastWill message: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : MQTT Last will enable |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.12.9 | ScalarwtWebGraphAnalog57761MQTTLastWillTopic | read-write | mandatory | MQTT Last Will Topic. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.12.10 | ScalarwtWebGraphAnalog57761MQTTLastWillMsg | read-write | mandatory | MQTT Last Will message. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.12.11 | ScalarwtWebGraphAnalog57761MQTTLastWillQoS | read-write | mandatory | Binary coded MQTT Publish QoS: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: QoS 0 Bit 1: QoS 1 Bit 2: QoS 2 Bit 3-7:unused |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.12.12 | ScalarwtWebGraphAnalog57761MQTTLastWillRetain | read-write | mandatory | Binary coded MQTT Publish Retain properties: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : retain enable Bit 1-7 : unused |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.12.13 | ScalarwtWebGraphAnalog57761MQTTLastWillConnectEnable | read-write | mandatory | Bit 0 activate MQTT LastWill Connect message: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : MQTT Last will connect message e… |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.12.14 | ScalarwtWebGraphAnalog57761MQTTLastWillConnectMsg | read-write | mandatory | MQTT Last Will Connect message will be send with the QoS and Retain settings of the LastWill message. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.13 | NodewtWebGraphAnalog57761REST | |||
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.13.1 | ScalarwtWebGraphAnalog57761RESTEnable | read-write | mandatory | Bit 0 activates REST : Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : REST enable |
| 1.3.6.1.4.1.5040.1.2.28.3.1.3.13.2 | ScalarwtWebGraphAnalog57761RESTDigestAuthEnable | read-write | mandatory | Bit 0 activates Digest-Authentification: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Digest Auth enable |
| 1.3.6.1.4.1.5040.1.2.28.3.1.4 | NodewtWebGraphAnalog57761Datalogger | |||
| 1.3.6.1.4.1.5040.1.2.28.3.1.4.1 | ScalarwtWebGraphAnalog57761LoggerTimebase | read-write | mandatory | Time base of the data logger |
| 1.3.6.1.4.1.5040.1.2.28.3.1.4.2 | ScalarwtWebGraphAnalog57761LoggerSensorSel | read-write | mandatory | Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2-7: unused |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5 | NodewtWebGraphAnalog57761Alarm | |||
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.1 | ScalarwtWebGraphAnalog57761AlarmCount | read-only | mandatory | Number of independent alarms. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.2 | TablewtWebGraphAnalog57761AlarmIfTable | not-accessible | mandatory | List of alarm indices. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.2.1 | RowwtWebGraphAnalog57761AlarmIfEntry | not-accessible | mandatory | Numbers of the alarms. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.2.1.1 | ColumnwtWebGraphAnalog57761AlarmNo | read-only | mandatory | Alarm number. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3 | TablewtWebGraphAnalog57761AlarmTable | not-accessible | mandatory | List of settings depending on the alarm number. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1 | RowwtWebGraphAnalog57761AlarmEntry | not-accessible | mandatory | Alarm parameters of the individual alarms. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.1 | ColumnwtWebGraphAnalog57761AlarmTrigger | read-write | mandatory | Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: Bit 0: Timer Bit 1: ColdStart Bit 2: WarmStart Octet 4: Bit 0: Sensor 1 Bit 1: Sensor… |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.2 | ColumnwtWebGraphAnalog57761AlarmMin1 | read-write | mandatory | Minimum sensor 1 with maximum 3 decimal places. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.3 | ColumnwtWebGraphAnalog57761AlarmMax1 | read-write | mandatory | Maximum sensor 1 with maximum 3 decimal places. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.4 | ColumnwtWebGraphAnalog57761AlarmHysteresis1 | read-write | mandatory | Reading changes of this size clears the alarm state (MAX-hyst, MIN+hyst.) with maximum 3 decimal places. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.5 | ColumnwtWebGraphAnalog57761AlarmDelay | read-write | mandatory | Alarm will be delayed by setting this time while stable alarm condition occur (time in minutes). |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.6 | ColumnwtWebGraphAnalog57761AlarmInterval | read-write | mandatory | Send interval for alarm messages. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.7 | ColumnwtWebGraphAnalog57761AlarmEnable | read-write | mandatory | Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: TCP Client enable Bit 3: … |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.8 | ColumnwtWebGraphAnalog57761AlarmEMailAddr | read-write | mandatory | E-Mail address for sending the alarm mail to. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.9 | ColumnwtWebGraphAnalog57761AlarmMailSubject | read-write | mandatory | Subject line for alarm mail. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.10 | ColumnwtWebGraphAnalog57761AlarmMailText | read-write | mandatory | Alarm mail text: <Mn> provides the current temperature; n = 1..2. <Z> provides the current time. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.11 | ColumnwtWebGraphAnalog57761AlarmManagerIP | read-write | mandatory | Name or IP address of the SNMP Manager which accepts the trap. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.12 | ColumnwtWebGraphAnalog57761AlarmTrapText | read-write | mandatory | This text is sent in the trap body. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.13 | ColumnwtWebGraphAnalog57761AlarmMailOptions | read-write | mandatory | Binary coded options: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Attach Logger.csv Enable Bit 1 : CSV-Data_since_last_report Bit 2-7: unu… |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.14 | ColumnwtWebGraphAnalog57761AlarmTcpIpAddr | read-write | mandatory | Name or IP address of the TCP server which accepts the trap. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.15 | ColumnwtWebGraphAnalog57761AlarmTcpPort | read-write | mandatory | Port number of the TCP server which accepts the trap. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.16 | ColumnwtWebGraphAnalog57761AlarmTcpText | read-write | mandatory | This text is sent in the TCP trap body. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.17 | ColumnwtWebGraphAnalog57761AlarmClearMailSubject | read-write | mandatory | Subject line for alarm clear mail. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.18 | ColumnwtWebGraphAnalog57761AlarmClearMailText | read-write | mandatory | Alarm clear mail text: <Mn> provides the current temperature; n = 1..2. <Z> provides the current time. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.19 | ColumnwtWebGraphAnalog57761AlarmClearTrapText | read-write | mandatory | This text is sent in the trap body. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.20 | ColumnwtWebGraphAnalog57761AlarmClearTcpText | read-write | mandatory | This text is sent in the TCP trap body. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.21 | ColumnwtWebGraphAnalog57761AlarmMin2 | read-write | mandatory | Minimum sensor 2 with maximum 3 decimal places. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.22 | ColumnwtWebGraphAnalog57761AlarmMax2 | read-write | mandatory | Maximum sensor 2 with maximum 2 decimal places. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.23 | ColumnwtWebGraphAnalog57761AlarmHysteresis2 | read-write | mandatory | Hysterese rel. sensor 2 with maximum 3 decimal places. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.24 | ColumnwtWebGraphAnalog57761AlarmSyslogIpAddr | read-write | mandatory | IP address of the syslog server to which the Webio device should send syslog messages. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.25 | ColumnwtWebGraphAnalog57761AlarmSyslogPort | read-write | mandatory | Port number of the syslog server to which the Webio device should send syslog messages. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.26 | ColumnwtWebGraphAnalog57761AlarmSyslogText | read-write | mandatory | Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.27 | ColumnwtWebGraphAnalog57761AlarmSyslogClearText | read-write | mandatory | Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body of … |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.28 | ColumnwtWebGraphAnalog57761AlarmFtpDataPort | read-write | mandatory | Local data port: 1..65535 or AUTO: the next free port will be assigned. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.29 | ColumnwtWebGraphAnalog57761AlarmFtpFileName | read-write | mandatory | Name of the file including path informations. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.30 | ColumnwtWebGraphAnalog57761AlarmFtpText | read-write | mandatory | Message text to store on the FTP server. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.31 | ColumnwtWebGraphAnalog57761AlarmFtpClearText | read-write | mandatory | Alarm clear message to store on the FTP server. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.32 | ColumnwtWebGraphAnalog57761AlarmFtpOption | read-write | mandatory | Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unu… |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.33 | ColumnwtWebGraphAnalog57761AlarmTimerCron | read-write | mandatory | This entry defines a time window for alarm 1-8 and a activation time for the report. A time window is definied by start and stop time stamp, seperated by a spa… |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.39 | ColumnwtWebGraphAnalog57761AlarmName | read-write | mandatory | Alert name |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.40 | ColumnwtWebGraphAnalog57761AlarmActive | read-write | mandatory | Alert active 1 = ON 0 = OFF |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.61 | ColumnwtWebGraphAnalog57761AlarmHttpReqAuthEnable | read-write | mandatory | Binary coded options, select only one option at the same time: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 1-7: unused Bit 0 : HHTP Request Au… |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.62 | ColumnwtWebGraphAnalog57761AlarmHttpReqAuthUser | read-write | mandatory | HTTP Request: User |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.63 | ColumnwtWebGraphAnalog57761AlarmHttpReqAuthPassword | read-write | mandatory | HTTP Request: Password |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.64 | ColumnwtWebGraphAnalog57761AlarmHttpReqSetUrl | read-write | mandatory | HTTP Request: Set URL |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.65 | ColumnwtWebGraphAnalog57761AlarmHttpReqClearUrl | read-write | mandatory | HTTP Request: Clear URL |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.66 | ColumnwtWebGraphAnalog57761AlarmHttpReqServerPort | read-write | mandatory | HTTP Request: Server Port |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.67 | ColumnwtWebGraphAnalog57761AlarmMqttTopicPath | read-write | mandatory | MQTT Publish: Topic path |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.68 | ColumnwtWebGraphAnalog57761AlarmMqttTopicSetTopic | read-write | mandatory | MQTT Publish: Topic SET message |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.69 | ColumnwtWebGraphAnalog57761AlarmMqttTopicClear | read-write | mandatory | MQTT Publish: Topic CLEAR message |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.70 | ColumnwtWebGraphAnalog57761AlarmSensorLostSelection | read-write | mandatory | Binary coded options: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 1-7: unused Bit 0 : Sensor 0 |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.71 | ColumnwtWebGraphAnalog57761AlarmLimitWindow | read-write | mandatory | If window type is INSIDE the alarm is genereted when the temperature is greater minumum value and lower than maximum value. If window type is OUTSIDE the alarm… |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.76 | ColumnwtWebGraphAnalog57761AlarmSnmpManagerPort | read-write | mandatory | Port number of the SNMP Manager to which the Webio device should send SNMP traps. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.77 | ColumnwtWebGraphAnalog57761AlarmMqttQoS | read-write | mandatory | Binary coded value: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: QoS 0 Bit 1: QoS 1 Bit 2: QoS 2 Bit 3-7:unused |
| 1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.78 | ColumnwtWebGraphAnalog57761AlarmMqttRetain | read-write | mandatory | Binary coded value: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : retain enable Bit 1-7 : unused |
| 1.3.6.1.4.1.5040.1.2.28.3.1.6 | NodewtWebGraphAnalog57761Graphics | |||
| 1.3.6.1.4.1.5040.1.2.28.3.1.6.1 | NodewtWebGraphAnalog57761GraphicsBase | |||
| 1.3.6.1.4.1.5040.1.2.28.3.1.6.1.1 | ScalarwtWebGraphAnalog57761GraphicsBaseEnable | read-write | mandatory | Defines the viewing options of the graphic: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Auto scroll enable Bit 1 : Show table Bit 2 : Show… |
| 1.3.6.1.4.1.5040.1.2.28.3.1.6.1.2 | ScalarwtWebGraphAnalog57761GraphicsBaseWidth | read-write | mandatory | Defines the width of the graphic in pixels. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.6.1.3 | ScalarwtWebGraphAnalog57761GraphicsBaseHeight | read-write | mandatory | Defines the height of the graphic in pixels. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.6.1.4 | ScalarwtWebGraphAnalog57761GraphicsBaseFrameColor | read-write | mandatory | Frame color definition in RGB. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.6.1.5 | ScalarwtWebGraphAnalog57761GraphicsBaseBackgroundColor | read-write | mandatory | Background color definition in RGB. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.6.1.6 | ScalarwtWebGraphAnalog57761GraphicsBasePollingrate | read-write | mandatory | Defines the pollingrate in seconds, which defines the refreshing intervall of the graphic. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.6.2 | NodewtWebGraphAnalog57761GraphicsSelect | |||
| 1.3.6.1.4.1.5040.1.2.28.3.1.6.2.1 | ScalarwtWebGraphAnalog57761GraphicsSelectDisplaySensorSel | read-write | mandatory | Binary coded sensor selection: only selected sensors will be shown in the graphical presentation: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit … |
| 1.3.6.1.4.1.5040.1.2.28.3.1.6.2.2 | ScalarwtWebGraphAnalog57761GraphicsSelectDisplayShowExtrem | read-write | mandatory | Binary coded sensor selection: only selected sensors will be shown with minima and maxima: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sens… |
| 1.3.6.1.4.1.5040.1.2.28.3.1.6.2.3 | TablewtWebGraphAnalog57761SensorColor2Table | not-accessible | mandatory | List of sensor colors for the praphical presentation. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.6.2.3.1 | RowwtWebGraphAnalog57761SensorColor2Entry | not-accessible | mandatory | Numbers of the sensors. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.6.2.3.1.1 | ColumnwtWebGraphAnalog57761GraphicsSensorColor | read-write | mandatory | Color of the sensors at the praphical presention. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.6.2.3.1.2 | ColumnwtWebGraphAnalog57761GraphicsSelectScale | read-write | mandatory | Assignes one of 4 scales to a sensor: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Use Scale 1 Bit 1 : Use Scale 2 Bit 2-7: unused |
| 1.3.6.1.4.1.5040.1.2.28.3.1.6.3 | NodewtWebGraphAnalog57761GraphicsScale | |||
| 1.3.6.1.4.1.5040.1.2.28.3.1.6.3.1 | ScalarwtWebGraphAnalog57761GraphicsScaleAutoScaleEnable | read-write | mandatory | Select the Auto Scale Mode: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Scale 1 Auto scale enable Bit 1 : Scale 2 Auto scale enable Bit 2-… |
| 1.3.6.1.4.1.5040.1.2.28.3.1.6.3.2 | ScalarwtWebGraphAnalog57761GraphicsScaleAutoFitEnable | read-write | mandatory | Select the Auto Fit Mode:: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Scale 1 Auto fit enable Bit 1 : Scale 2 Auto fit enable Bit 2-7: un… |
| 1.3.6.1.4.1.5040.1.2.28.3.1.6.3.3 | ScalarwtWebGraphAnalog57761GraphicsScale1Min | read-only | mandatory | Scale 1: Minimum. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.6.3.4 | ScalarwtWebGraphAnalog57761GraphicsScale2Min | read-only | mandatory | Scale 2: Minimum. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.6.3.7 | ScalarwtWebGraphAnalog57761GraphicsScale1Max | read-only | mandatory | Scale 1: Maximum. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.6.3.8 | ScalarwtWebGraphAnalog57761GraphicsScale2Max | read-only | mandatory | Scale 2: Maximum. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.6.3.11 | ScalarwtWebGraphAnalog57761GraphicsScale1Unit | read-only | mandatory | Scale 1: Unit. |
| 1.3.6.1.4.1.5040.1.2.28.3.1.6.3.12 | ScalarwtWebGraphAnalog57761GraphicsScale2Unit | read-only | mandatory | Scale 2: Unit. |
| 1.3.6.1.4.1.5040.1.2.28.3.2 | NodewtWebGraphAnalog57761Ports | |||
| 1.3.6.1.4.1.5040.1.2.28.3.2.1 | TablewtWebGraphAnalog57761PortTable | not-accessible | mandatory | List of settings depending on the sensor number. |
| 1.3.6.1.4.1.5040.1.2.28.3.2.1.1 | RowwtWebGraphAnalog57761PortEntry | not-accessible | mandatory | Sensor parameters for the individual sensors. |
| 1.3.6.1.4.1.5040.1.2.28.3.2.1.1.1 | ColumnwtWebGraphAnalog57761PortName | read-write | mandatory | Name of the sensor. |
| 1.3.6.1.4.1.5040.1.2.28.3.2.1.1.2 | ColumnwtWebGraphAnalog57761PortText | read-write | mandatory | Description of the sensor. |
| 1.3.6.1.4.1.5040.1.2.28.3.2.1.1.3 | ColumnwtWebGraphAnalog57761PortOffset1 | read-write | mandatory | Offset calibration: Offset in degrees with maximum 3 decimal places at set point 1. |
| 1.3.6.1.4.1.5040.1.2.28.3.2.1.1.4 | ColumnwtWebGraphAnalog57761SetPoint1 | read-write | mandatory | Offset calibration: Reference set point 1 in degrees with maximum 3 decimal places. |
| 1.3.6.1.4.1.5040.1.2.28.3.2.1.1.5 | ColumnwtWebGraphAnalog57761PortOffset2 | read-write | mandatory | Offset calibration: Offset in degrees with maximum 3 decimal places at set point 2. |
| 1.3.6.1.4.1.5040.1.2.28.3.2.1.1.6 | ColumnwtWebGraphAnalog57761SetPoint2 | read-write | mandatory | Offset calibration: Reference set point 2 in degrees with maximum 3 decimal places. |
| 1.3.6.1.4.1.5040.1.2.28.3.2.1.1.7 | ColumnwtWebGraphAnalog57761PortComment | read-write | mandatory | Offset calibration: informations of date, name of operator, reference devices. |
| 1.3.6.1.4.1.5040.1.2.28.3.2.1.1.8 | ColumnwtWebGraphAnalog57761PortSensorSelect | read-write | mandatory | Binary coded options for sensor 1: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : 0-20mA (default) Bit 1 : 4-20mA Bit 2 : Disconnect Bit 3-7:… |
| 1.3.6.1.4.1.5040.1.2.28.3.2.1.1.9 | ColumnwtWebGraphAnalog57761PortUnit | read-write | mandatory | User scale: displayed unit. |
| 1.3.6.1.4.1.5040.1.2.28.3.2.1.1.10 | ColumnwtWebGraphAnalog57761PortScale0 | read-write | mandatory | User scale: displayed value in 1/1000 at 0% full scale range. Range: -999999.999 to 999999.999 |
| 1.3.6.1.4.1.5040.1.2.28.3.2.1.1.11 | ColumnwtWebGraphAnalog57761PortScale100 | read-write | mandatory | User scale: displayed value in 1/1000 at 100% full scale range. Range: -999999.999 to 999999.999 |
| 1.3.6.1.4.1.5040.1.2.28.3.2.1.1.12 | ColumnwtWebGraphAnalog57761PortOutputMode | read-write | mandatory | This binary coded output mode defines the individual operation mode for any output. More than one mode must not be selected. If an output mode is selected, Bit… |
| 1.3.6.1.4.1.5040.1.2.28.3.2.1.1.13 | ColumnwtWebGraphAnalog57761PortInputMode | read-write | mandatory | This binary coded input mode defines the individual operation mode for any input. More than one mode must not be selected. If an input mode is selected, Bit 5 … |
| 1.3.6.1.4.1.5040.1.2.28.3.2.1.1.16 | ColumnwtWebGraphAnalog57761PortPresetValue | read-write | mandatory | This value will be set after reset or initialisation. |
| 1.3.6.1.4.1.5040.1.2.28.3.3 | NodewtWebGraphAnalog57761Manufact | |||
| 1.3.6.1.4.1.5040.1.2.28.3.3.1 | ScalarwtWebGraphAnalog57761MfName | read-write | mandatory | Manufacturer company name |
| 1.3.6.1.4.1.5040.1.2.28.3.3.2 | ScalarwtWebGraphAnalog57761MfAddr | read-write | mandatory | Manufacturer address. |
| 1.3.6.1.4.1.5040.1.2.28.3.3.3 | ScalarwtWebGraphAnalog57761MfHotline | read-write | mandatory | Manufacturer hotline. |
| 1.3.6.1.4.1.5040.1.2.28.3.3.4 | ScalarwtWebGraphAnalog57761MfInternet | read-write | mandatory | Manufacturer Internet address. |
| 1.3.6.1.4.1.5040.1.2.28.3.3.5 | ScalarwtWebGraphAnalog57761MfDeviceTyp | read-write | mandatory | Manufacturer device name (model number). |
| 1.3.6.1.4.1.5040.1.2.28.3.3.6 | ScalarwtWebGraphAnalog57761MfOrderNo | read-write | mandatory | Manufacturer part number. |
| 1.3.6.1.4.1.5040.1.2.28.4 | NodewtWebGraphAnalog57761Diag | |||
| 1.3.6.1.4.1.5040.1.2.28.4.1 | ScalarwtWebGraphAnalog57761DiagErrorCount | read-only | mandatory | Number of entries in the error memory. |
| 1.3.6.1.4.1.5040.1.2.28.4.2 | ScalarwtWebGraphAnalog57761DiagBinaryError | read-only | mandatory | Error causes coded bit-by-bit. |
| 1.3.6.1.4.1.5040.1.2.28.4.3 | ScalarwtWebGraphAnalog57761DiagErrorIndex | read-write | mandatory | The value of this variable is used as an index to read an error massege from wtWebGraphAnalog57761DiagErrorMessage. Errors are numbered from 1 to wtWebGraphAna… |
| 1.3.6.1.4.1.5040.1.2.28.4.4 | ScalarwtWebGraphAnalog57761DiagErrorMessage | read-only | mandatory | Using wtWebGraphAnalog57761DiagErrorIndex as an index, the appropriate message is available. |
| 1.3.6.1.4.1.5040.1.2.28.4.5 | ScalarwtWebGraphAnalog57761DiagErrorClear | write-only | mandatory | Writing 1 into this variable clears all diagnosis messages. |
| 1.3.6.1.4.1.5040.1.2.28.31 | NodewtWebGraphAnalog57761Alert1 | This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled. | ||
| 1.3.6.1.4.1.5040.1.2.28.32 | NodewtWebGraphAnalog57761Alert2 | This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled. | ||
| 1.3.6.1.4.1.5040.1.2.28.33 | NodewtWebGraphAnalog57761Alert3 | This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled. | ||
| 1.3.6.1.4.1.5040.1.2.28.34 | NodewtWebGraphAnalog57761Alert4 | This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled. | ||
| 1.3.6.1.4.1.5040.1.2.28.35 | NodewtWebGraphAnalog57761Alert5 | This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled. | ||
| 1.3.6.1.4.1.5040.1.2.28.36 | NodewtWebGraphAnalog57761Alert6 | This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled. | ||
| 1.3.6.1.4.1.5040.1.2.28.37 | NodewtWebGraphAnalog57761Alert7 | This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled. | ||
| 1.3.6.1.4.1.5040.1.2.28.38 | NodewtWebGraphAnalog57761Alert8 | This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled. | ||
| 1.3.6.1.4.1.5040.1.2.28.39 | NodewtWebGraphAnalog57761AlertReport | This SNMP trap is generated when the report was triggered, SNMP trap enable is set and SNMP is enabled. | ||
| 1.3.6.1.4.1.5040.1.2.28.91 | NodewtWebGraphAnalog57761Alert9 | This SNMP trap is generated when Alarm 1 was cleared, SNMP trap enable is set and SNMP is enabled. | ||
| 1.3.6.1.4.1.5040.1.2.28.92 | NodewtWebGraphAnalog57761Alert10 | This SNMP trap is generated when Alarm 2 was cleared, SNMP trap enable is set and SNMP is enabled. | ||
| 1.3.6.1.4.1.5040.1.2.28.93 | NodewtWebGraphAnalog57761Alert11 | This SNMP trap is generated when Alarm 3 was cleared, SNMP trap enable is set and SNMP is enabled. | ||
| 1.3.6.1.4.1.5040.1.2.28.94 | NodewtWebGraphAnalog57761Alert12 | This SNMP trap is generated when Alarm 4 was cleared, SNMP trap enable is set and SNMP is enabled. | ||
| 1.3.6.1.4.1.5040.1.2.28.95 | NodewtWebGraphAnalog57761Alert13 | This SNMP trap is generated when Alarm 5 was cleared, SNMP trap enable is set and SNMP is enabled. | ||
| 1.3.6.1.4.1.5040.1.2.28.96 | NodewtWebGraphAnalog57761Alert14 | This SNMP trap is generated when Alarm 6 was cleared, SNMP trap enable is set and SNMP is enabled. | ||
| 1.3.6.1.4.1.5040.1.2.28.97 | NodewtWebGraphAnalog57761Alert15 | This SNMP trap is generated when Alarm 7 was cleared, SNMP trap enable is set and SNMP is enabled. | ||
| 1.3.6.1.4.1.5040.1.2.28.98 | NodewtWebGraphAnalog57761Alert16 | This SNMP trap is generated when Alarm 8 was cleared, SNMP trap enable is set and SNMP is enabled. | ||
| 1.3.6.1.4.1.5040.1.2.28.110 | NodewtWebGraphAnalog57761AlertDiag | This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled. |