MIB Viewer

WebGraph-OLD-2xThermometer-US-MIB

221 objects
No module-level DESCRIPTION found.
Imported Objects
RFC-1212OBJECT-TYPE
RFC-1215TRAP-TYPE
RFC1155-SMIenterprises IpAddress NetworkAddress TimeTicks
RFC1213-MIBDisplayString PhysAddress
OIDNameAccessStatusDescription
1.3.6.1.4.1.5040Nodewut
1.3.6.1.4.1.5040.1NodewtComServer
1.3.6.1.4.1.5040.1.2NodewtWebio
1.3.6.1.4.1.5040.1.2.7NodewtWebioAn2Graph
1.3.6.1.4.1.5040.1.2.7.1NodewtWebioAn2GraphTemp
1.3.6.1.4.1.5040.1.2.7.1.1ScalarwtWebioAn2GraphSensorsread-onlymandatoryNumber of temperature sensors
1.3.6.1.4.1.5040.1.2.7.1.2TablewtWebioAn2GraphSensorTablenot-accessiblemandatoryList of sensors.
1.3.6.1.4.1.5040.1.2.7.1.2.1RowwtWebioAn2GraphSensorEntrynot-accessiblemandatoryTemperature sensor numbers.
1.3.6.1.4.1.5040.1.2.7.1.2.1.1ColumnwtWebioAn2GraphSensorNoread-onlymandatoryTemperature sensor number.
1.3.6.1.4.1.5040.1.2.7.1.3TablewtWebioAn2GraphTempValueTablenot-accessiblemandatoryList of temperature values corresponding to the channel numbers.
1.3.6.1.4.1.5040.1.2.7.1.3.1RowwtWebioAn2GraphTempValueEntrynot-accessiblemandatoryTemperatures of the sensors.
1.3.6.1.4.1.5040.1.2.7.1.3.1.1ColumnwtWebioAn2GraphTempValueread-onlymandatoryTemperature value of the sensor, ASCII, 5 characters in length.
1.3.6.1.4.1.5040.1.2.7.1.4TablewtWebioAn2GraphBinaryTempValueTablenot-accessiblemandatoryList of binary temperature values corresponding to the channel numbers.
1.3.6.1.4.1.5040.1.2.7.1.4.1RowwtWebioAn2GraphBinaryTempValueEntrynot-accessiblemandatoryBinary temperature values of the sensors.
1.3.6.1.4.1.5040.1.2.7.1.4.1.1ColumnwtWebioAn2GraphBinaryTempValueread-onlymandatoryBinary temperature value of the sensor in 1/10 degrees Celsius, signed number, 0x4FFF6 indicates an invalid measured value.
1.3.6.1.4.1.5040.1.2.7.1.8TablewtWebioAn2GraphTempValuePktTablenot-accessiblemandatoryList of temperature values corresponding to the channel numbers.
1.3.6.1.4.1.5040.1.2.7.1.8.1RowwtWebioAn2GraphTempValuePktEntrynot-accessiblemandatoryTemperatures of the sensors.
1.3.6.1.4.1.5040.1.2.7.1.8.1.1ColumnwtWebioAn2GraphTempValuePktread-onlymandatoryTemperature value of the sensor, ASCII, 5 characters in length, decimal point.
1.3.6.1.4.1.5040.1.2.7.2NodewtWebioAn2GraphSessCntrl
1.3.6.1.4.1.5040.1.2.7.2.1ScalarwtWebioAn2GraphSessCntrlPasswordread-writemandatoryEntering this password opens a session which is ended by writing a 1 to wtWebioAn2GraphSessCntrlLogout. When read this variable provides a string of length zer…
1.3.6.1.4.1.5040.1.2.7.2.2ScalarwtWebioAn2GraphSessCntrlConfigModeread-onlymandatoryWhen the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is…
1.3.6.1.4.1.5040.1.2.7.2.3ScalarwtWebioAn2GraphSessCntrlLogoutread-writemandatoryIf the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters ar…
1.3.6.1.4.1.5040.1.2.7.2.4ScalarwtWebioAn2GraphSessCntrlAdminPasswordread-writemandatoryThis password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid p…
1.3.6.1.4.1.5040.1.2.7.2.5ScalarwtWebioAn2GraphSessCntrlConfigPasswordread-writemandatoryThis password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was ass…
1.3.6.1.4.1.5040.1.2.7.3NodewtWebioAn2GraphConfig
1.3.6.1.4.1.5040.1.2.7.3.1NodewtWebioAn2GraphDevice
1.3.6.1.4.1.5040.1.2.7.3.1.1NodewtWebioAn2GraphText
1.3.6.1.4.1.5040.1.2.7.3.1.1.1ScalarwtWebioAn2GraphDeviceNameread-writemandatoryName of the Webio, which is user definable.
1.3.6.1.4.1.5040.1.2.7.3.1.1.2ScalarwtWebioAn2GraphDeviceTextread-writemandatoryDescription of the Webio, which is user definable.
1.3.6.1.4.1.5040.1.2.7.3.1.1.3ScalarwtWebioAn2GraphDeviceLocationread-writemandatoryDescription of the location of the Webio, which is user definable.
1.3.6.1.4.1.5040.1.2.7.3.1.1.4ScalarwtWebioAn2GraphDeviceContactread-writemandatoryContact address of the system operator of the Webio, which is user definable.
1.3.6.1.4.1.5040.1.2.7.3.1.2NodewtWebioAn2GraphTimeDate
1.3.6.1.4.1.5040.1.2.7.3.1.2.1NodewtWebioAn2GraphTimeZone
1.3.6.1.4.1.5040.1.2.7.3.1.2.1.1ScalarwtWebioAn2GraphTzOffsetHrsread-writemandatoryOffset hours for the time zone (winter time) with respect to UTC.
1.3.6.1.4.1.5040.1.2.7.3.1.2.1.2ScalarwtWebioAn2GraphTzOffsetMinread-writemandatoryOffset minutes for the time zone (winter time) with respect to UTC.
1.3.6.1.4.1.5040.1.2.7.3.1.2.1.3ScalarwtWebioAn2GraphTzEnableread-writemandatoryBinary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone
1.3.6.1.4.1.5040.1.2.7.3.1.2.1.4ScalarwtWebioAn2GraphStTzOffsetHrsread-writemandatoryOffset hours of the time zone (summer time) with respect to UTC.
1.3.6.1.4.1.5040.1.2.7.3.1.2.1.5ScalarwtWebioAn2GraphStTzOffsetMinread-writemandatoryOffset minutes of the time zone (summer time) with respect to UTC.
1.3.6.1.4.1.5040.1.2.7.3.1.2.1.6ScalarwtWebioAn2GraphStTzEnableread-writemandatoryBinary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime
1.3.6.1.4.1.5040.1.2.7.3.1.2.1.7ScalarwtWebioAn2GraphStTzStartMonthread-writemandatoryMonth in which the change is made from winter time to summer time.
1.3.6.1.4.1.5040.1.2.7.3.1.2.1.8ScalarwtWebioAn2GraphStTzStartModeread-writemandatoryMode of the day of the week for which the change is made from winter time to summer time.
1.3.6.1.4.1.5040.1.2.7.3.1.2.1.9ScalarwtWebioAn2GraphStTzStartWdayread-writemandatoryDay of the week on which the change is made from winter time to summer time
1.3.6.1.4.1.5040.1.2.7.3.1.2.1.10ScalarwtWebioAn2GraphStTzStartHrsread-writemandatoryHour in which the time zone is changed from winter to summer time with respect to UTC.
1.3.6.1.4.1.5040.1.2.7.3.1.2.1.11ScalarwtWebioAn2GraphStTzStartMinread-writemandatoryMinute in which the time zone is changed from winter to summer time with respect to UTC.
1.3.6.1.4.1.5040.1.2.7.3.1.2.1.12ScalarwtWebioAn2GraphStTzStopMonthread-writemandatoryMonth in which the change is made from summer time to winter time.
1.3.6.1.4.1.5040.1.2.7.3.1.2.1.13ScalarwtWebioAn2GraphStTzStopModeread-writemandatoryMode of the week day on which the change is made from summer time to winter time.
1.3.6.1.4.1.5040.1.2.7.3.1.2.1.14ScalarwtWebioAn2GraphStTzStopWdayread-writemandatoryDay of the week on which the change is made from summer time to winter time.
1.3.6.1.4.1.5040.1.2.7.3.1.2.1.15ScalarwtWebioAn2GraphStTzStopHrsread-writemandatoryHour at which the time zone is changed from summer to winter time with respect to UTC.
1.3.6.1.4.1.5040.1.2.7.3.1.2.1.16ScalarwtWebioAn2GraphStTzStopMinread-writemandatoryMinute at which the time zone is changed from summer to winter time with respect to UTC.
1.3.6.1.4.1.5040.1.2.7.3.1.2.2NodewtWebioAn2GraphTimeServer
1.3.6.1.4.1.5040.1.2.7.3.1.2.2.1ScalarwtWebioAn2GraphTimeServer1read-writemandatoryIP address or name of the 1st time server in ASCII
1.3.6.1.4.1.5040.1.2.7.3.1.2.2.2ScalarwtWebioAn2GraphTimeServer2read-writemandatoryIP address or name of the 2nd time server in ASCII
1.3.6.1.4.1.5040.1.2.7.3.1.2.2.3ScalarwtWebioAn2GraphTsEnableread-writemandatoryBinary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server
1.3.6.1.4.1.5040.1.2.7.3.1.2.2.4ScalarwtWebioAn2GraphTsSyncTimeread-writemandatoryDaily synchronisation time with the time server (hour: 0-23).
1.3.6.1.4.1.5040.1.2.7.3.1.2.3NodewtWebioAn2GraphDeviceClock
1.3.6.1.4.1.5040.1.2.7.3.1.2.3.1ScalarwtWebioAn2GraphClockHrsread-writemandatoryClock hours taking into account the time zone settings.
1.3.6.1.4.1.5040.1.2.7.3.1.2.3.2ScalarwtWebioAn2GraphClockMinread-writemandatoryClock minutes taking into account the time zone settings.
1.3.6.1.4.1.5040.1.2.7.3.1.2.3.3ScalarwtWebioAn2GraphClockDayread-writemandatoryDate: Day of the month, taking into account the time zone settings.
1.3.6.1.4.1.5040.1.2.7.3.1.2.3.4ScalarwtWebioAn2GraphClockMonthread-writemandatoryDate: Month, taking into account the time zone settings.
1.3.6.1.4.1.5040.1.2.7.3.1.2.3.5ScalarwtWebioAn2GraphClockYearread-writemandatoryDate: Year, taking into account the time zone settings.
1.3.6.1.4.1.5040.1.2.7.3.1.3NodewtWebioAn2GraphBasic
1.3.6.1.4.1.5040.1.2.7.3.1.3.1NodewtWebioAn2GraphNetwork
1.3.6.1.4.1.5040.1.2.7.3.1.3.1.1ScalarwtWebioAn2GraphIpAddressread-writemandatoryIP address of the Webio
1.3.6.1.4.1.5040.1.2.7.3.1.3.1.2ScalarwtWebioAn2GraphSubnetMaskread-writemandatorySubnet mask of the Webio
1.3.6.1.4.1.5040.1.2.7.3.1.3.1.3ScalarwtWebioAn2GraphGatewayread-writemandatoryGateway of the Webio
1.3.6.1.4.1.5040.1.2.7.3.1.3.1.4ScalarwtWebioAn2GraphDnsServer1read-writemandatoryIP address of the 1st DNS server in ASCII
1.3.6.1.4.1.5040.1.2.7.3.1.3.1.5ScalarwtWebioAn2GraphDnsServer2read-writemandatoryIP address of the 2nd DNS server in ASCII
1.3.6.1.4.1.5040.1.2.7.3.1.3.1.6ScalarwtWebioAn2GraphAddConfigread-writemandatoryAdditional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: BOOTP disable Bit 1: DHCP disable
1.3.6.1.4.1.5040.1.2.7.3.1.3.2NodewtWebioAn2GraphHTTP
1.3.6.1.4.1.5040.1.2.7.3.1.3.2.1ScalarwtWebioAn2GraphStartupread-writemandatoryBinary coded start page: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: Index.htm Bit 2: Home.htm Bit 3: User.htm Only one page may be selecte…
1.3.6.1.4.1.5040.1.2.7.3.1.3.2.2ScalarwtWebioAn2GraphGetHeaderEnableread-writemandatoryIf these bits are set, every answer of a short form GET question will be lead by the IP-address and name of the device and/or a HTTP header: Octet 1: unused Oc…
1.3.6.1.4.1.5040.1.2.7.3.1.3.2.3ScalarwtWebioAn2GraphHttpPortread-writemandatoryDefinition of the standard HTML port (Default: 80).
1.3.6.1.4.1.5040.1.2.7.3.1.3.3NodewtWebioAn2GraphMail
1.3.6.1.4.1.5040.1.2.7.3.1.3.3.1ScalarwtWebioAn2GraphMailAdNameread-writemandatoryDevice name for mail administration.
1.3.6.1.4.1.5040.1.2.7.3.1.3.3.2ScalarwtWebioAn2GraphMailReplyread-writemandatoryReply address for the mail server.
1.3.6.1.4.1.5040.1.2.7.3.1.3.3.3ScalarwtWebioAn2GraphMailServerread-writemandatoryName or IP address of the mail server.
1.3.6.1.4.1.5040.1.2.7.3.1.3.3.4ScalarwtWebioAn1MailEnableread-writemandatorySet this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable
1.3.6.1.4.1.5040.1.2.7.3.1.3.3.5ScalarwtWebioAn2GraphMailAuthenticationread-writemandatorySelection of the authentication modi: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: u…
1.3.6.1.4.1.5040.1.2.7.3.1.3.3.6ScalarwtWebioAn2GraphMailAuthUserread-writemandatoryName of the user to be authenticated.
1.3.6.1.4.1.5040.1.2.7.3.1.3.3.7ScalarwtWebioAn2GraphMailAuthPasswordread-writemandatoryAuthentication password.
1.3.6.1.4.1.5040.1.2.7.3.1.3.3.8ScalarwtWebioAn2GraphMailPop3Serverread-writemandatoryName or Ip-address of the POP3 Servers.
1.3.6.1.4.1.5040.1.2.7.3.1.3.4NodewtWebioAn2GraphSNMP
1.3.6.1.4.1.5040.1.2.7.3.1.3.4.1ScalarwtWebioAn2GraphSnmpCommunityStringReadread-writemandatoryCommunity string read only
1.3.6.1.4.1.5040.1.2.7.3.1.3.4.2ScalarwtWebioAn2GraphSnmpCommunityStringReadWriteread-writemandatoryCommunity string read / write
1.3.6.1.4.1.5040.1.2.7.3.1.3.4.3ScalarwtWebioAn2GraphSystemTrapManagerIPread-writemandatoryName or IP address of the TCP server which accepts the system trap.
1.3.6.1.4.1.5040.1.2.7.3.1.3.4.4ScalarwtWebioAn2GraphSystemTrapEnableread-writemandatoryBinary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2-7: unused
1.3.6.1.4.1.5040.1.2.7.3.1.3.4.5ScalarwtWebioAn2GraphSnmpEnableread-writemandatorySet bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compare…
1.3.6.1.4.1.5040.1.2.7.3.1.3.4.6ScalarwtWebioAn2GraphSnmpCommunityStringTrapread-writemandatoryCommunity string send within traps.
1.3.6.1.4.1.5040.1.2.7.3.1.3.5NodewtWebioAn2GraphUDP
1.3.6.1.4.1.5040.1.2.7.3.1.3.5.1ScalarwtWebioAn2GraphUdpPortread-writemandatoryUdp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device.
1.3.6.1.4.1.5040.1.2.7.3.1.3.5.2ScalarwtWebioAn2GraphUdpEnableread-writemandatorySet this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable
1.3.6.1.4.1.5040.1.2.7.3.1.3.6NodewtWebioAn2GraphSyslog
1.3.6.1.4.1.5040.1.2.7.3.1.3.6.1ScalarwtWebioAn2GraphSyslogServerIPread-writemandatoryName or IP address of the Syslog server, which accepts the Syslog messgaes.
1.3.6.1.4.1.5040.1.2.7.3.1.3.6.2ScalarwtWebioAn2GraphSyslogServerPortread-writemandatoryPortnumber of the Syslog servers, default 514.
1.3.6.1.4.1.5040.1.2.7.3.1.3.6.3ScalarwtWebioAn2GraphSyslogSystemMessagesEnableread-writemandatoryBinary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused
1.3.6.1.4.1.5040.1.2.7.3.1.3.6.4ScalarwtWebioAn2GraphSyslogEnableread-writemandatorySet bit 0 to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable
1.3.6.1.4.1.5040.1.2.7.3.1.3.7NodewtWebioAn2GraphFTP
1.3.6.1.4.1.5040.1.2.7.3.1.3.7.1ScalarwtWebioAn2GraphFTPServerIPread-writemandatoryName or IP address of the FTP server, which accepts the FTP messages.
1.3.6.1.4.1.5040.1.2.7.3.1.3.7.2ScalarwtWebioAn2GraphFTPServerControlPortread-writemandatoryPortnumber of the control port of the FTP server, default 21.
1.3.6.1.4.1.5040.1.2.7.3.1.3.7.3ScalarwtWebioAn2GraphFTPUserNameread-writemandatoryFTP Loggin: user name.
1.3.6.1.4.1.5040.1.2.7.3.1.3.7.4ScalarwtWebioAn2GraphFTPPasswordread-writemandatoryFTP Loggin: user password.
1.3.6.1.4.1.5040.1.2.7.3.1.3.7.5ScalarwtWebioAn2GraphFTPAccountread-writemandatoryFTP Loggin: name of account.
1.3.6.1.4.1.5040.1.2.7.3.1.3.7.6ScalarwtWebioAn2GraphFTPOptionread-writemandatoryBit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit …
1.3.6.1.4.1.5040.1.2.7.3.1.3.7.7ScalarwtWebioAn2GraphFTPEnableread-writemandatorySet Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable
1.3.6.1.4.1.5040.1.2.7.3.1.4NodewtWebioAn2GraphDatalogger
1.3.6.1.4.1.5040.1.2.7.3.1.4.1ScalarwtWebioAn2GraphLoggerTimebaseread-writemandatoryTime base of the data logger
1.3.6.1.4.1.5040.1.2.7.3.1.4.2ScalarwtWebioAn2GraphLoggerSensorSelread-writemandatoryBinary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2: Sensor 3 Bit 3: Sensor 4 Bit 4…
1.3.6.1.4.1.5040.1.2.7.3.1.4.3ScalarwtWebioAn2GraphDisplaySensorSelread-writemandatoryBinary coded sensor selection: only selected sensors will be shown in the graphical presentation: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit …
1.3.6.1.4.1.5040.1.2.7.3.1.4.5ScalarwtWebioAn2GraphAutoScaleEnableread-writemandatoryIf bit 0 is set, vertical auto scale is enabled: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Auto Scale enable
1.3.6.1.4.1.5040.1.2.7.3.1.4.6ScalarwtWebioAn2GraphVerticalUpperLimitread-writemandatoryThis value defines the maximum temperature shown in the graphical presentation, if no auto scaling is selected. Temperature in degrees with maximum 2 decimal p…
1.3.6.1.4.1.5040.1.2.7.3.1.4.7ScalarwtWebioAn2GraphVerticalLowerLimitread-writemandatoryThis value defines the minimum temperature shown in the graphical presentation, if no auto scaling is selected. Temperature in degrees with maximum 2 decimal p…
1.3.6.1.4.1.5040.1.2.7.3.1.4.8ScalarwtWebioAn2GraphHorizontalZoomread-writemandatoryDefines the default zoom stage, if no auto scaling is selected.
1.3.6.1.4.1.5040.1.2.7.3.1.5NodewtWebioAn2GraphAlarm
1.3.6.1.4.1.5040.1.2.7.3.1.5.1ScalarwtWebioAn2GraphAlarmCountread-onlymandatoryNumber of independent alarms.
1.3.6.1.4.1.5040.1.2.7.3.1.5.2TablewtWebioAn2GraphAlarmIfTablenot-accessiblemandatoryList of alarm indices.
1.3.6.1.4.1.5040.1.2.7.3.1.5.2.1RowwtWebioAn2GraphAlarmIfEntrynot-accessiblemandatoryNumbers of the alarms.
1.3.6.1.4.1.5040.1.2.7.3.1.5.2.1.1ColumnwtWebioAn2GraphAlarmNoread-onlymandatoryAlarm number.
1.3.6.1.4.1.5040.1.2.7.3.1.5.3TablewtWebioAn2GraphAlarmTablenot-accessiblemandatoryList of settings depending on the alarm number.
1.3.6.1.4.1.5040.1.2.7.3.1.5.3.1RowwtWebioAn2GraphAlarmEntrynot-accessiblemandatoryAlarm parameters of the individual alarms.
1.3.6.1.4.1.5040.1.2.7.3.1.5.3.1.1ColumnwtWebioAn2GraphAlarmTriggerread-writemandatoryBinary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: Bit 0: Timer Bit 1: ColdStart Bit 2: WarmStart Octet 4: Bit 0: Sensor 1 Bit 1: Sensor…
1.3.6.1.4.1.5040.1.2.7.3.1.5.3.1.2ColumnwtWebioAn2GraphAlarmMinread-writemandatoryMinimum temperature in degrees with maximum 2 decimal places.
1.3.6.1.4.1.5040.1.2.7.3.1.5.3.1.3ColumnwtWebioAn2GraphAlarmMaxread-writemandatoryMaximum temperature in degrees with maximum 2 decimal places.
1.3.6.1.4.1.5040.1.2.7.3.1.5.3.1.4ColumnwtWebioAn2GraphAlarmHysteresisread-writemandatoryTemperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.) , in degrees with maximum 2 decimal places.
1.3.6.1.4.1.5040.1.2.7.3.1.5.3.1.5ColumnwtWebioAn2GraphAlarmDelayread-writemandatoryAlarm will be delayed by setting this time while stable alarm condition occur (time in minutes).
1.3.6.1.4.1.5040.1.2.7.3.1.5.3.1.6ColumnwtWebioAn2GraphAlarmIntervalread-writemandatorySend interval for alarm messages.
1.3.6.1.4.1.5040.1.2.7.3.1.5.3.1.7ColumnwtWebioAn2GraphAlarmEnableread-writemandatoryBinary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: TCP Client enable
1.3.6.1.4.1.5040.1.2.7.3.1.5.3.1.8ColumnwtWebioAn2GraphAlarmEMailAddrread-writemandatoryE-Mail address for sending the alarm mail to.
1.3.6.1.4.1.5040.1.2.7.3.1.5.3.1.9ColumnwtWebioAn2GraphAlarmMailSubjectread-writemandatorySubject line for alarm mail.
1.3.6.1.4.1.5040.1.2.7.3.1.5.3.1.10ColumnwtWebioAn2GraphAlarmMailTextread-writemandatoryAlarm mail text: <Tn> provides the current temperature; n = 1..2. <Z> provides the current time.
1.3.6.1.4.1.5040.1.2.7.3.1.5.3.1.11ColumnwtWebioAn2GraphAlarmManagerIPread-writemandatoryName or IP address of the SNMP Manager which accepts the trap.
1.3.6.1.4.1.5040.1.2.7.3.1.5.3.1.12ColumnwtWebioAn2GraphAlarmTrapTextread-writemandatoryThis text is sent in the trap body.
1.3.6.1.4.1.5040.1.2.7.3.1.5.3.1.13ColumnwtWebioAn2GraphAlarmMailOptionsread-writemandatoryBinary coded options: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Attach Thermo.csv Enable Bit 1 : CSV-Data_since_last_report Bit 2-7: unu…
1.3.6.1.4.1.5040.1.2.7.3.1.5.3.1.14ColumnwtWebioAn2GraphAlarmTcpIpAddrread-writemandatoryName or IP address of the TCP server which accepts the trap.
1.3.6.1.4.1.5040.1.2.7.3.1.5.3.1.15ColumnwtWebioAn2GraphAlarmTcpPortread-writemandatoryPort number of the TCP server which accepts the trap.
1.3.6.1.4.1.5040.1.2.7.3.1.5.3.1.16ColumnwtWebioAn2GraphAlarmTcpTextread-writemandatoryThis text is sent in the TCP trap body.
1.3.6.1.4.1.5040.1.2.7.3.1.5.3.1.17ColumnwtWebioAn2GraphAlarmClearMailSubjectread-writemandatorySubject line for alarm clear mail.
1.3.6.1.4.1.5040.1.2.7.3.1.5.3.1.18ColumnwtWebioAn2GraphAlarmClearMailTextread-writemandatoryAlarm clear mail text: <Tn> provides the current temperature; n = 1..2. <Z> provides the current time.
1.3.6.1.4.1.5040.1.2.7.3.1.5.3.1.19ColumnwtWebioAn2GraphAlarmClearTrapTextread-writemandatoryThis text is sent in the trap body.
1.3.6.1.4.1.5040.1.2.7.3.1.5.3.1.20ColumnwtWebioAn2GraphAlarmClearTcpTextread-writemandatoryThis text is sent in the TCP trap body.
1.3.6.1.4.1.5040.1.2.7.3.1.5.3.1.21ColumnwtWebioAn2GraphAlarmSyslogIpAddrread-writemandatoryIP address of the syslog server to which the Webio device should send syslog messages.
1.3.6.1.4.1.5040.1.2.7.3.1.5.3.1.22ColumnwtWebioAn2GraphAlarmSyslogPortread-writemandatoryPort number of the syslog server to which the Webio device should send syslog messages.
1.3.6.1.4.1.5040.1.2.7.3.1.5.3.1.23ColumnwtWebioAn2GraphAlarmSyslogTextread-writemandatoryEvery message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.
1.3.6.1.4.1.5040.1.2.7.3.1.5.3.1.24ColumnwtWebioAn2GraphAlarmSyslogClearTextread-writemandatoryEvery message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.
1.3.6.1.4.1.5040.1.2.7.3.1.5.3.1.25ColumnwtWebioAn2GraphAlarmFtpDataPortread-writemandatoryLocal data port: 1..65535 or AUTO: the next free port will be assigned.
1.3.6.1.4.1.5040.1.2.7.3.1.5.3.1.26ColumnwtWebioAn2GraphAlarmFtpFileNameread-writemandatoryName of the file including path informations.
1.3.6.1.4.1.5040.1.2.7.3.1.5.3.1.27ColumnwtWebioAn2GraphAlarmFtpTextread-writemandatoryMessage text to store on the FTP server.
1.3.6.1.4.1.5040.1.2.7.3.1.5.3.1.28ColumnwtWebioAn2GraphAlarmFtpClearTextread-writemandatoryAlarm clear message to store on the FTP server.
1.3.6.1.4.1.5040.1.2.7.3.1.5.3.1.29ColumnwtWebioAn2GraphAlarmFtpOptionsread-writemandatoryBinary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unu…
1.3.6.1.4.1.5040.1.2.7.3.1.5.3.1.30ColumnwtWebioAn2GraphAlarmTimerCronread-writemandatoryThis entry contains 5 text fields space or tab seperated for time trigger definition. Each field must match with the actual time to trigger a message, weekday …
1.3.6.1.4.1.5040.1.2.7.3.1.6NodewtWebioAn2GraphGraphics
1.3.6.1.4.1.5040.1.2.7.3.1.6.1NodewtWebioAn2GraphGraphicsBase
1.3.6.1.4.1.5040.1.2.7.3.1.6.1.1ScalarwtWebioAn2GraphGraphicsBaseEnableread-writemandatoryDefines the viewing options of the graphic: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Auto scroll enable Bit 1 : Show table Bit 2 : Show…
1.3.6.1.4.1.5040.1.2.7.3.1.6.1.2ScalarwtWebioAn2GraphGraphicsBaseWidthread-writemandatoryDefines the width of the graphic in pixels.
1.3.6.1.4.1.5040.1.2.7.3.1.6.1.3ScalarwtWebioAn2GraphGraphicsBaseHeightread-writemandatoryDefines the height of the graphic in pixels.
1.3.6.1.4.1.5040.1.2.7.3.1.6.1.4ScalarwtWebioAn2GraphGraphicsBaseFrameColorread-writemandatoryFrame color definition in RGB.
1.3.6.1.4.1.5040.1.2.7.3.1.6.1.5ScalarwtWebioAn2GraphGraphicsBaseBackgroundColorread-writemandatoryBackground color definition in RGB.
1.3.6.1.4.1.5040.1.2.7.3.1.6.1.6ScalarwtWebioAn2GraphGraphicsBasePollingrateread-writemandatoryDefines the pollingrate in seconds, which defines the refreshing intervall of the graphic.
1.3.6.1.4.1.5040.1.2.7.3.1.6.2NodewtWebioAn2GraphGraphicsSelect
1.3.6.1.4.1.5040.1.2.7.3.1.6.2.1ScalarwtWebioAn2GraphGraphicsSelectDisplaySensorSelread-writemandatoryBinary coded sensor selection: only selected sensors will be shown in the graphical presentation: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit …
1.3.6.1.4.1.5040.1.2.7.3.1.6.2.2ScalarwtWebioAn2GraphGraphicsSelectDisplayShowExtremread-writemandatoryBinary coded sensor selection: only selected sensors will be shown with minima and maxima: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sens…
1.3.6.1.4.1.5040.1.2.7.3.1.6.2.3TablewtWebioAn2GraphSensorColorTablenot-accessiblemandatoryList of sensor colors for the praphical presentation.
1.3.6.1.4.1.5040.1.2.7.3.1.6.2.3.1RowwtWebioAn2GraphSensorColorEntrynot-accessiblemandatoryNumbers of the sensors.
1.3.6.1.4.1.5040.1.2.7.3.1.6.2.3.1.1ColumnwtWebioAn2GraphGraphicsSensorColorread-writemandatoryColor of the sensors at the praphical presention.
1.3.6.1.4.1.5040.1.2.7.3.1.6.2.3.1.1ColumnwtWebioAn2GraphSensorColorread-writemandatoryColor of the sensors at the praphical presention.
1.3.6.1.4.1.5040.1.2.7.3.1.6.2.3.1.2ColumnwtWebioAn2GraphGraphicsSelectScaleread-writemandatoryAssignes one of 4 scales to a sensor: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Use Scale 1 Bit 1 : Use Scale 2 Bit 2 : Use Scale 3 Bit …
1.3.6.1.4.1.5040.1.2.7.3.1.6.3NodewtWebioAn2GraphGraphicsScale
1.3.6.1.4.1.5040.1.2.7.3.1.6.3.1ScalarwtWebioAn2GraphGraphicsScaleAutoScaleEnableread-writemandatorySelect the Auto Scale Mode: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Scale 1 Auto scale enable Bit 1 : Scale 2 Auto scale enable Bit 2 …
1.3.6.1.4.1.5040.1.2.7.3.1.6.3.2ScalarwtWebioAn2GraphGraphicsScaleAutoFitEnableread-writemandatorySelect the Auto Fit Mode:: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Scale 1 Auto fit enable Bit 1 : Scale 2 Auto fit enable Bit 2 : Sca…
1.3.6.1.4.1.5040.1.2.7.3.1.6.3.3ScalarwtWebioAn2GraphGraphicsScale1Minread-onlymandatoryScale 1: Minimum.
1.3.6.1.4.1.5040.1.2.7.3.1.6.3.4ScalarwtWebioAn2GraphGraphicsScale2Minread-onlymandatoryScale 2: Minimum.
1.3.6.1.4.1.5040.1.2.7.3.1.6.3.5ScalarwtWebioAn2GraphGraphicsScale3Minread-onlymandatoryScale 3: Minimum.
1.3.6.1.4.1.5040.1.2.7.3.1.6.3.6ScalarwtWebioAn2GraphGraphicsScale4Minread-onlymandatoryScale 4: Minimum.
1.3.6.1.4.1.5040.1.2.7.3.1.6.3.7ScalarwtWebioAn2GraphGraphicsScale1Maxread-onlymandatoryScale 1: Maximum.
1.3.6.1.4.1.5040.1.2.7.3.1.6.3.8ScalarwtWebioAn2GraphGraphicsScale2Maxread-onlymandatoryScale 2: Maximum.
1.3.6.1.4.1.5040.1.2.7.3.1.6.3.9ScalarwtWebioAn2GraphGraphicsScale3Maxread-onlymandatoryScale 3: Maximum.
1.3.6.1.4.1.5040.1.2.7.3.1.6.3.10ScalarwtWebioAn2GraphGraphicsScale4Maxread-onlymandatoryScale 4: Maximum.
1.3.6.1.4.1.5040.1.2.7.3.1.6.3.11ScalarwtWebioAn2GraphGraphicsScale1Unitread-onlymandatoryScale 1: Unit.
1.3.6.1.4.1.5040.1.2.7.3.1.6.3.12ScalarwtWebioAn2GraphGraphicsScale2Unitread-onlymandatoryScale 2: Unit.
1.3.6.1.4.1.5040.1.2.7.3.1.6.3.13ScalarwtWebioAn2GraphGraphicsScale3Unitread-onlymandatoryScale 3: Unit.
1.3.6.1.4.1.5040.1.2.7.3.1.6.3.14ScalarwtWebioAn2GraphGraphicsScale4Unitread-onlymandatoryScale 4: Unit.
1.3.6.1.4.1.5040.1.2.7.3.2NodewtWebioAn2GraphPorts
1.3.6.1.4.1.5040.1.2.7.3.2.1TablewtWebioAn2GraphPortTablenot-accessiblemandatoryList of settings depending on the sensor number.
1.3.6.1.4.1.5040.1.2.7.3.2.1.1RowwtWebioAn2GraphPortEntrynot-accessiblemandatorySensor parameters for the individual sensors.
1.3.6.1.4.1.5040.1.2.7.3.2.1.1.1ColumnwtWebioAn2GraphPortNameread-writemandatoryName of the sensor.
1.3.6.1.4.1.5040.1.2.7.3.2.1.1.2ColumnwtWebioAn2GraphPortTextread-writemandatoryDescription of the sensor.
1.3.6.1.4.1.5040.1.2.7.3.2.1.1.3ColumnwtWebioAn2GraphPortOffset1read-writemandatoryOffset calibration: Offset in degrees with maximum 2 decimal places at temperature 1.
1.3.6.1.4.1.5040.1.2.7.3.2.1.1.4ColumnwtWebioAn2GraphPortTemperature1read-writemandatoryOffset calibration: Reference temperature 1 in degrees with maximum 2 decimal places.
1.3.6.1.4.1.5040.1.2.7.3.2.1.1.5ColumnwtWebioAn2GraphPortOffset2read-writemandatoryOffset calibration: Offset in degrees with maximum 2 decimal places at temperature 2.
1.3.6.1.4.1.5040.1.2.7.3.2.1.1.6ColumnwtWebioAn2GraphPortTemperature2read-writemandatoryOffset calibration: Reference temperature 1 in degrees with maximum 2 decimal places.
1.3.6.1.4.1.5040.1.2.7.3.2.1.1.7ColumnwtWebioAn2GraphPortCommentread-writemandatoryOffset calibration: informations of date, name of operator, reference devices.
1.3.6.1.4.1.5040.1.2.7.3.2.1.1.8ColumnwtWebioAn2GraphPortSensorSelectread-writemandatoryBin�r kodierte Optionen f?r Sensor: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0 : PT100 Bit 1 : PT1000 (default) Bit 2-7: ungenut…
1.3.6.1.4.1.5040.1.2.7.3.3NodewtWebioAn2GraphManufact
1.3.6.1.4.1.5040.1.2.7.3.3.1ScalarwtWebioAn2GraphMfNameread-writemandatoryManufacturer company name
1.3.6.1.4.1.5040.1.2.7.3.3.2ScalarwtWebioAn2GraphMfAddrread-writemandatoryManufacturer address.
1.3.6.1.4.1.5040.1.2.7.3.3.3ScalarwtWebioAn2GraphMfHotlineread-writemandatoryManufacturer hotline.
1.3.6.1.4.1.5040.1.2.7.3.3.4ScalarwtWebioAn2GraphMfInternetread-writemandatoryManufacturer Internet address.
1.3.6.1.4.1.5040.1.2.7.3.3.5ScalarwtWebioAn2GraphMfDeviceTypread-writemandatoryManufacturer device name (model number).
1.3.6.1.4.1.5040.1.2.7.3.3.6ScalarwtWebioAn2GraphMfOrderNoread-writemandatoryManufacturer part number.
1.3.6.1.4.1.5040.1.2.7.4NodewtWebioAn2GraphDiag
1.3.6.1.4.1.5040.1.2.7.4.1ScalarwtWebioAn2GraphDiagErrorCountread-onlymandatoryNumber of entries in the error memory.
1.3.6.1.4.1.5040.1.2.7.4.2ScalarwtWebioAn2GraphDiagBinaryErrorread-onlymandatoryError causes coded bit-by-bit.
1.3.6.1.4.1.5040.1.2.7.4.3ScalarwtWebioAn2GraphDiagErrorIndexread-writemandatoryThe value of this variable is used as an index to read an error massege from wtWebioAn2GraphDiagErrorMessage. Errors are numbered from 1 to wtWebioAn2GraphDiag…
1.3.6.1.4.1.5040.1.2.7.4.4ScalarwtWebioAn2GraphDiagErrorMessageread-onlymandatoryUsing wtWebioAn2GraphDiagErrorIndex as an index, the appropriate message is available.
1.3.6.1.4.1.5040.1.2.7.4.5ScalarwtWebioAn2GraphDiagErrorClearwrite-onlymandatoryWriting 1 into this variable clears all diagnosis messages.
1.3.6.1.4.1.5040.1.2.7.21NodewtWebioAn2GraphAlert1This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled.
1.3.6.1.4.1.5040.1.2.7.22NodewtWebioAn2GraphAlert2This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled.
1.3.6.1.4.1.5040.1.2.7.23NodewtWebioAn2GraphAlert3This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled.
1.3.6.1.4.1.5040.1.2.7.24NodewtWebioAn2GraphAlert4This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled.
1.3.6.1.4.1.5040.1.2.7.25NodewtWebioAn2GraphAlert5This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled.
1.3.6.1.4.1.5040.1.2.7.26NodewtWebioAn2GraphAlert6This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled.
1.3.6.1.4.1.5040.1.2.7.27NodewtWebioAn2GraphAlert7This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled.
1.3.6.1.4.1.5040.1.2.7.28NodewtWebioAn2GraphAlert8This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled.
1.3.6.1.4.1.5040.1.2.7.81NodewtWebioAn2GraphAlert9This SNMP trap is generated when Alarm 1 was cleared, SNMP trap enable is set and SNMP is enabled.
1.3.6.1.4.1.5040.1.2.7.82NodewtWebioAn2GraphAlert10This SNMP trap is generated when Alarm 2 was cleared, SNMP trap enable is set and SNMP is enabled.
1.3.6.1.4.1.5040.1.2.7.83NodewtWebioAn2GraphAlert11This SNMP trap is generated when Alarm 3 was cleared, SNMP trap enable is set and SNMP is enabled.
1.3.6.1.4.1.5040.1.2.7.84NodewtWebioAn2GraphAlert12This SNMP trap is generated when Alarm 4 was cleared, SNMP trap enable is set and SNMP is enabled.
1.3.6.1.4.1.5040.1.2.7.85NodewtWebioAn2GraphAlert13This SNMP trap is generated when Alarm 5 was cleared, SNMP trap enable is set and SNMP is enabled.
1.3.6.1.4.1.5040.1.2.7.86NodewtWebioAn2GraphAlert14This SNMP trap is generated when Alarm 6 was cleared, SNMP trap enable is set and SNMP is enabled.
1.3.6.1.4.1.5040.1.2.7.87NodewtWebioAn2GraphAlert15This SNMP trap is generated when Alarm 7 was cleared, SNMP trap enable is set and SNMP is enabled.
1.3.6.1.4.1.5040.1.2.7.88NodewtWebioAn2GraphAlert16This SNMP trap is generated when Alarm 8 was cleared, SNMP trap enable is set and SNMP is enabled.
1.3.6.1.4.1.5040.1.2.7.110NodewtWebioAn2GraphAlertDiagThis SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled.