WebGraph-OLD-Thermo-Hygrometer-US-MIB
196 objects
No module-level DESCRIPTION found.
Imported Objects
| RFC-1212 | OBJECT-TYPE |
| RFC-1215 | TRAP-TYPE |
| RFC1155-SMI | enterprises IpAddress NetworkAddress TimeTicks |
| RFC1213-MIB | DisplayString PhysAddress |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.5040 | Nodewut | |||
| 1.3.6.1.4.1.5040.1 | NodewtComServer | |||
| 1.3.6.1.4.1.5040.1.2 | NodewtWebio | |||
| 1.3.6.1.4.1.5040.1.2.9 | NodewtWebGraphThermHygro | |||
| 1.3.6.1.4.1.5040.1.2.9.1 | NodewtWebGraphThermHygroTemp | |||
| 1.3.6.1.4.1.5040.1.2.9.1.1 | ScalarwtWebGraphThermHygroSensors | read-only | mandatory | Number of sensors |
| 1.3.6.1.4.1.5040.1.2.9.1.2 | TablewtWebGraphThermHygroSensorTable | not-accessible | mandatory | List of sensors. |
| 1.3.6.1.4.1.5040.1.2.9.1.2.1 | RowwtWebGraphThermHygroSensorEntry | not-accessible | mandatory | List of sensor numbers. |
| 1.3.6.1.4.1.5040.1.2.9.1.2.1.1 | ColumnwtWebGraphThermHygroSensorNo | read-only | mandatory | Sensor number. |
| 1.3.6.1.4.1.5040.1.2.9.1.3 | TablewtWebGraphThermHygroTempValueTable | not-accessible | mandatory | List of measurement values corresponding to the channel numbers. |
| 1.3.6.1.4.1.5040.1.2.9.1.3.1 | RowwtWebGraphThermHygroTempValueEntry | not-accessible | mandatory | Measurement values of the sensors. |
| 1.3.6.1.4.1.5040.1.2.9.1.3.1.1 | ColumnwtWebGraphThermHygroTempValue | read-only | mandatory | Measurement value of the sensor, ASCII, 5 characters in length. |
| 1.3.6.1.4.1.5040.1.2.9.1.4 | TablewtWebGraphThermHygroBinaryTempValueTable | not-accessible | mandatory | List of binary measurement values corresponding to the channel numbers. |
| 1.3.6.1.4.1.5040.1.2.9.1.4.1 | RowwtWebGraphThermHygroBinaryTempValueEntry | not-accessible | mandatory | Binary measurement values of the sensors. |
| 1.3.6.1.4.1.5040.1.2.9.1.4.1.1 | ColumnwtWebGraphThermHygroBinaryTempValue | read-only | mandatory | Binary measurement value of the sensor in 1/10 degrees Celsius or 1/10 per cent, signed number, 0x4FFF6 indicates an invalid measured value. |
| 1.3.6.1.4.1.5040.1.2.9.2 | NodewtWebGraphThermHygroSessCntrl | |||
| 1.3.6.1.4.1.5040.1.2.9.2.1 | ScalarwtWebGraphThermHygroSessCntrlPassword | read-write | mandatory | Entering this password opens a session which is ended by writing a 1 to wtWebGraphThermHygroSessCntrlLogout. When read this variable provides a string of lengt… |
| 1.3.6.1.4.1.5040.1.2.9.2.2 | ScalarwtWebGraphThermHygroSessCntrlConfigMode | read-only | mandatory | When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is… |
| 1.3.6.1.4.1.5040.1.2.9.2.3 | ScalarwtWebGraphThermHygroSessCntrlLogout | read-write | mandatory | If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters ar… |
| 1.3.6.1.4.1.5040.1.2.9.2.4 | ScalarwtWebGraphThermHygroSessCntrlAdminPassword | read-write | mandatory | This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid p… |
| 1.3.6.1.4.1.5040.1.2.9.2.5 | ScalarwtWebGraphThermHygroSessCntrlConfigPassword | read-write | mandatory | This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was ass… |
| 1.3.6.1.4.1.5040.1.2.9.3 | NodewtWebGraphThermHygroConfig | |||
| 1.3.6.1.4.1.5040.1.2.9.3.1 | NodewtWebGraphThermHygroDevice | |||
| 1.3.6.1.4.1.5040.1.2.9.3.1.1 | NodewtWebGraphThermHygroText | |||
| 1.3.6.1.4.1.5040.1.2.9.3.1.1.1 | ScalarwtWebGraphThermHygroDeviceName | read-write | mandatory | Name of the Webio, which is user definable. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.1.2 | ScalarwtWebGraphThermHygroDeviceText | read-write | mandatory | Description of the Webio, which is user definable. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.1.3 | ScalarwtWebGraphThermHygroDeviceLocation | read-write | mandatory | Description of the location of the Webio, which is user definable. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.1.4 | ScalarwtWebGraphThermHygroDeviceContact | read-write | mandatory | Contact address of the system operator of the Webio, which is user definable. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.2 | NodewtWebGraphThermHygroTimeDate | |||
| 1.3.6.1.4.1.5040.1.2.9.3.1.2.1 | NodewtWebGraphThermHygroTimeZone | |||
| 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.1 | ScalarwtWebGraphThermHygroTzOffsetHrs | read-write | mandatory | Offset hours for the time zone (winter time) with respect to UTC. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.2 | ScalarwtWebGraphThermHygroTzOffsetMin | read-write | mandatory | Offset minutes for the time zone (winter time) with respect to UTC. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.3 | ScalarwtWebGraphThermHygroTzEnable | read-write | mandatory | Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone |
| 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.4 | ScalarwtWebGraphThermHygroStTzOffsetHrs | read-write | mandatory | Offset hours of the time zone (summer time) with respect to UTC. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.5 | ScalarwtWebGraphThermHygroStTzOffsetMin | read-write | mandatory | Offset minutes of the time zone (summer time) with respect to UTC. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.6 | ScalarwtWebGraphThermHygroStTzEnable | read-write | mandatory | Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime |
| 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.7 | ScalarwtWebGraphThermHygroStTzStartMonth | read-write | mandatory | Month in which the change is made from winter time to summer time. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.8 | ScalarwtWebGraphThermHygroStTzStartMode | read-write | mandatory | Mode of the day of the week for which the change is made from winter time to summer time. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.9 | ScalarwtWebGraphThermHygroStTzStartWday | read-write | mandatory | Day of the week on which the change is made from winter time to summer time |
| 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.10 | ScalarwtWebGraphThermHygroStTzStartHrs | read-write | mandatory | Hour in which the time zone is changed from winter to summer time with respect to UTC. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.11 | ScalarwtWebGraphThermHygroStTzStartMin | read-write | mandatory | Minute in which the time zone is changed from winter to summer time with respect to UTC. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.12 | ScalarwtWebGraphThermHygroStTzStopMonth | read-write | mandatory | Month in which the change is made from summer time to winter time. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.13 | ScalarwtWebGraphThermHygroStTzStopMode | read-write | mandatory | Mode of the week day on which the change is made from summer time to winter time. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.14 | ScalarwtWebGraphThermHygroStTzStopWday | read-write | mandatory | Day of the week on which the change is made from summer time to winter time. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.15 | ScalarwtWebGraphThermHygroStTzStopHrs | read-write | mandatory | Hour at which the time zone is changed from summer to winter time with respect to UTC. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.2.1.16 | ScalarwtWebGraphThermHygroStTzStopMin | read-write | mandatory | Minute at which the time zone is changed from summer to winter time with respect to UTC. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.2.2 | NodewtWebGraphThermHygroTimeServer | |||
| 1.3.6.1.4.1.5040.1.2.9.3.1.2.2.1 | ScalarwtWebGraphThermHygroTimeServer1 | read-write | mandatory | IP address or name of the 1st time server in ASCII |
| 1.3.6.1.4.1.5040.1.2.9.3.1.2.2.2 | ScalarwtWebGraphThermHygroTimeServer2 | read-write | mandatory | IP address or name of the 2nd time server in ASCII |
| 1.3.6.1.4.1.5040.1.2.9.3.1.2.2.3 | ScalarwtWebGraphThermHygroTsEnable | read-write | mandatory | Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server |
| 1.3.6.1.4.1.5040.1.2.9.3.1.2.2.4 | ScalarwtWebGraphThermHygroTsSyncTime | read-write | mandatory | Daily synchronisation time with the time server (hour: 0-23). |
| 1.3.6.1.4.1.5040.1.2.9.3.1.2.3 | NodewtWebGraphThermHygroDeviceClock | |||
| 1.3.6.1.4.1.5040.1.2.9.3.1.2.3.1 | ScalarwtWebGraphThermHygroClockHrs | read-write | mandatory | Clock hours taking into account the time zone settings. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.2.3.2 | ScalarwtWebGraphThermHygroClockMin | read-write | mandatory | Clock minutes taking into account the time zone settings. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.2.3.3 | ScalarwtWebGraphThermHygroClockDay | read-write | mandatory | Date: Day of the month, taking into account the time zone settings. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.2.3.4 | ScalarwtWebGraphThermHygroClockMonth | read-write | mandatory | Date: Month, taking into account the time zone settings. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.2.3.5 | ScalarwtWebGraphThermHygroClockYear | read-write | mandatory | Date: Year, taking into account the time zone settings. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.3 | NodewtWebGraphThermHygroBasic | |||
| 1.3.6.1.4.1.5040.1.2.9.3.1.3.1 | NodewtWebGraphThermHygroNetwork | |||
| 1.3.6.1.4.1.5040.1.2.9.3.1.3.1.1 | ScalarwtWebGraphThermHygroIpAddress | read-write | mandatory | IP address of the Webio |
| 1.3.6.1.4.1.5040.1.2.9.3.1.3.1.2 | ScalarwtWebGraphThermHygroSubnetMask | read-write | mandatory | Subnet mask of the Webio |
| 1.3.6.1.4.1.5040.1.2.9.3.1.3.1.3 | ScalarwtWebGraphThermHygroGateway | read-write | mandatory | Gateway of the Webio |
| 1.3.6.1.4.1.5040.1.2.9.3.1.3.1.4 | ScalarwtWebGraphThermHygroDnsServer1 | read-write | mandatory | IP address of the 1st DNS server in ASCII |
| 1.3.6.1.4.1.5040.1.2.9.3.1.3.1.5 | ScalarwtWebGraphThermHygroDnsServer2 | read-write | mandatory | IP address of the 2nd DNS server in ASCII |
| 1.3.6.1.4.1.5040.1.2.9.3.1.3.1.6 | ScalarwtWebGraphThermHygroAddConfig | read-write | mandatory | Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: BOOTP disable |
| 1.3.6.1.4.1.5040.1.2.9.3.1.3.2 | NodewtWebGraphThermHygroHTTP | |||
| 1.3.6.1.4.1.5040.1.2.9.3.1.3.2.1 | ScalarwtWebGraphThermHygroStartup | read-write | mandatory | Binary coded start page: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: Index.htm Bit 2: Home.htm Bit 3: User.htm Only one page may be selecte… |
| 1.3.6.1.4.1.5040.1.2.9.3.1.3.2.2 | ScalarwtWebGraphThermHygroGetHeaderEnable | read-write | mandatory | If this bit is set, every answer of a short form GET question will be lead by the IP-address and name of the device: Octet 1: unused Octet 2: unused Octet 3: u… |
| 1.3.6.1.4.1.5040.1.2.9.3.1.3.2.3 | ScalarwtWebGraphThermHygroHttpPort | read-write | mandatory | Definition of the standard HTML port (Default: 80). |
| 1.3.6.1.4.1.5040.1.2.9.3.1.3.3 | NodewtWebGraphThermHygroMail | |||
| 1.3.6.1.4.1.5040.1.2.9.3.1.3.3.1 | ScalarwtWebGraphThermHygroMailAdName | read-write | mandatory | Device name for mail administration. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.3.3.2 | ScalarwtWebGraphThermHygroMailReply | read-write | mandatory | Reply address for the mail server. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.3.3.3 | ScalarwtWebGraphThermHygroMailServer | read-write | mandatory | Name or IP address of the mail server. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.3.3.4 | ScalarwtWebioAn1MailEnable | read-write | mandatory | Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable |
| 1.3.6.1.4.1.5040.1.2.9.3.1.3.3.5 | ScalarwtWebGraphThermHygroMailAuthentication | read-write | mandatory | Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: u… |
| 1.3.6.1.4.1.5040.1.2.9.3.1.3.3.6 | ScalarwtWebGraphThermHygroMailAuthUser | read-write | mandatory | Name of the user to be authenticated. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.3.3.7 | ScalarwtWebGraphThermHygroMailAuthPassword | read-write | mandatory | Authentication password. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.3.3.8 | ScalarwtWebGraphThermHygroMailPop3Server | read-write | mandatory | Name or Ip-address of the POP3 Servers. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.3.4 | NodewtWebGraphThermHygroSNMP | |||
| 1.3.6.1.4.1.5040.1.2.9.3.1.3.4.1 | ScalarwtWebGraphThermHygroSnmpCommunityStringRead | read-write | mandatory | Community string read only |
| 1.3.6.1.4.1.5040.1.2.9.3.1.3.4.2 | ScalarwtWebGraphThermHygroSnmpCommunityStringReadWrite | read-write | mandatory | Community string read / write |
| 1.3.6.1.4.1.5040.1.2.9.3.1.3.4.3 | ScalarwtWebGraphThermHygroSystemTrapManagerIP | read-write | mandatory | Name or IP address of the TCP server which accepts the system trap. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.3.4.4 | ScalarwtWebGraphThermHygroSystemTrapEnable | read-write | mandatory | Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2-7: unused |
| 1.3.6.1.4.1.5040.1.2.9.3.1.3.4.5 | ScalarwtWebGraphThermHygroSnmpEnable | read-write | mandatory | Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compare… |
| 1.3.6.1.4.1.5040.1.2.9.3.1.3.4.6 | ScalarwtWebGraphThermHygroSnmpCommunityStringTrap | read-write | mandatory | Community string send within traps. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.3.5 | NodewtWebGraphThermHygroUDP | |||
| 1.3.6.1.4.1.5040.1.2.9.3.1.3.5.1 | ScalarwtWebGraphThermHygroUdpPort | read-write | mandatory | Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.3.5.2 | ScalarwtWebGraphThermHygroUdpEnable | read-write | mandatory | Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable |
| 1.3.6.1.4.1.5040.1.2.9.3.1.3.6 | NodewtWebGraphThermHygroSyslog | |||
| 1.3.6.1.4.1.5040.1.2.9.3.1.3.6.1 | ScalarwtWebGraphThermHygroSyslogServerIP | read-write | mandatory | Name or IP address of the Syslog server, which accepts the Syslog messgaes. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.3.6.2 | ScalarwtWebGraphThermHygroSyslogServerPort | read-write | mandatory | Portnumber of the Syslog servers, default 514. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.3.6.3 | ScalarwtWebGraphThermHygroSyslogSystemMessagesEnable | read-write | mandatory | Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused |
| 1.3.6.1.4.1.5040.1.2.9.3.1.3.6.4 | ScalarwtWebGraphThermHygroSyslogEnable | read-write | mandatory | Set bit 0to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable |
| 1.3.6.1.4.1.5040.1.2.9.3.1.3.7 | NodewtWebGraphThermHygroFTP | |||
| 1.3.6.1.4.1.5040.1.2.9.3.1.3.7.1 | ScalarwtWebGraphThermHygroFTPServerIP | read-write | mandatory | Name or IP address of the FTP server, which accepts the FTP messages. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.3.7.2 | ScalarwtWebGraphThermHygroFTPServerControlPort | read-write | mandatory | Portnumber of the control port of the FTP server, default 21. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.3.7.3 | ScalarwtWebGraphThermHygroFTPUserName | read-write | mandatory | FTP Loggin: user name. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.3.7.4 | ScalarwtWebGraphThermHygroFTPPassword | read-write | mandatory | FTP Loggin: user password. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.3.7.5 | ScalarwtWebGraphThermHygroFTPAccount | read-write | mandatory | FTP Loggin: name of account. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.3.7.6 | ScalarwtWebGraphThermHygroFTPOption | read-write | mandatory | Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit … |
| 1.3.6.1.4.1.5040.1.2.9.3.1.3.7.7 | ScalarwtWebGraphThermHygroFTPEnable | read-write | mandatory | Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable |
| 1.3.6.1.4.1.5040.1.2.9.3.1.4 | NodewtWebGraphThermHygroDatalogger | |||
| 1.3.6.1.4.1.5040.1.2.9.3.1.4.1 | ScalarwtWebGraphThermHygroLoggerTimebase | read-write | mandatory | Time base of the data logger |
| 1.3.6.1.4.1.5040.1.2.9.3.1.4.2 | ScalarwtWebGraphThermHygroLoggerSensorSel | read-write | mandatory | Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2-7: unused |
| 1.3.6.1.4.1.5040.1.2.9.3.1.4.3 | ScalarwtWebGraphThermHygroDisplaySensorSel | read-write | mandatory | Binary coded sensor selection: only selected sensors will be shown in the graphical presentation: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit … |
| 1.3.6.1.4.1.5040.1.2.9.3.1.4.4 | TablewtWebGraphThermHygroSensorColorTable | not-accessible | mandatory | List of sensor colors for the praphical presentation. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.4.4.1 | RowwtWebGraphThermHygroSensorColorEntry | not-accessible | mandatory | Index numbers of the sensors. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.4.4.1.1 | ColumnwtWebGraphThermHygroSensorColor | read-write | mandatory | Color of the sensors at the praphical presention. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.4.5 | ScalarwtWebGraphThermHygroAutoScaleEnable | read-write | mandatory | If bit 0 is set, vertical auto scale is enabled: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Auto Scale enable |
| 1.3.6.1.4.1.5040.1.2.9.3.1.4.6 | ScalarwtWebGraphThermHygroVerticalUpperLimit | read-write | mandatory | This value defines the maximum temperature shown in the graphical presentation, if no auto scaling is selected. Temperature in degrees with maximum 2 decimal p… |
| 1.3.6.1.4.1.5040.1.2.9.3.1.4.7 | ScalarwtWebGraphThermHygroVerticalLowerLimit | read-write | mandatory | This value defines the minimum temperature shown in the graphical presentation, if no auto scaling is selected. Temperature in degrees with maximum 2 decimal p… |
| 1.3.6.1.4.1.5040.1.2.9.3.1.4.8 | ScalarwtWebGraphThermHygroHorizontalZoom | read-write | mandatory | Defines the default zoom stage, if no auto scaling is selected. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.5 | NodewtWebGraphThermHygroAlarm | |||
| 1.3.6.1.4.1.5040.1.2.9.3.1.5.1 | ScalarwtWebGraphThermHygroAlarmCount | read-only | mandatory | Number of independent alarms. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.5.2 | TablewtWebGraphThermHygroAlarmIfTable | not-accessible | mandatory | List of alarm indices. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.5.2.1 | RowwtWebGraphThermHygroAlarmIfEntry | not-accessible | mandatory | Numbers of the alarms. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.5.2.1.1 | ColumnwtWebGraphThermHygroAlarmNo | read-only | mandatory | Alarm number. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.5.3 | TablewtWebGraphThermHygroAlarmTable | not-accessible | mandatory | List of settings depending on the alarm number. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1 | RowwtWebGraphThermHygroAlarmEntry | not-accessible | mandatory | Alarm parameters of the individual alarms. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.1 | ColumnwtWebGraphThermHygroAlarmTrigger | read-write | mandatory | Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: Bit 0: Timer Bit 1: ColdStart Bit 2: WarmStart Octet 4: Bit 0: Sensor 1 Bit 1: Sensor… |
| 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.2 | ColumnwtWebGraphThermHygroAlarmMin | read-write | mandatory | Minimum temperature in degrees with maximum 2 decimal places. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.3 | ColumnwtWebGraphThermHygroAlarmMax | read-write | mandatory | Maximum temperature in degrees with maximum 2 decimal places. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.4 | ColumnwtWebGraphThermHygroAlarmHysteresis | read-write | mandatory | Temperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.) , in degrees with maximum 2 decimal places. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.5 | ColumnwtWebGraphThermHygroAlarmDelay | read-write | mandatory | Alarm will be delayed by setting this time while stable alarm condition occur (time in minutes). |
| 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.6 | ColumnwtWebGraphThermHygroAlarmInterval | read-write | mandatory | Send interval for alarm messages. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.7 | ColumnwtWebGraphThermHygroAlarmEnable | read-write | mandatory | Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: TCP Client enable |
| 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.8 | ColumnwtWebGraphThermHygroAlarmEMailAddr | read-write | mandatory | E-Mail address for sending the alarm mail to. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.9 | ColumnwtWebGraphThermHygroAlarmMailSubject | read-write | mandatory | Subject line for alarm mail. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.10 | ColumnwtWebGraphThermHygroAlarmMailText | read-write | mandatory | Alarm mail text: <Tn> provides the current temperature; n = 1..8. <Z> provides the current time. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.11 | ColumnwtWebGraphThermHygroAlarmManagerIP | read-write | mandatory | Name or IP address of the SNMP Manager which accepts the trap. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.12 | ColumnwtWebGraphThermHygroAlarmTrapText | read-write | mandatory | This text is sent in the trap body. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.13 | ColumnwtWebGraphThermHygroAlarmMailOptions | read-write | mandatory | Binary coded options: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Attach Thermo.csv Enable Bit 1 : CSV-Data_since_last_report Bit 2-7: unu… |
| 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.14 | ColumnwtWebGraphThermHygroAlarmTcpIpAddr | read-write | mandatory | Name or IP address of the TCP server which accepts the trap. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.15 | ColumnwtWebGraphThermHygroAlarmTcpPort | read-write | mandatory | Port number of the TCP server which accepts the trap. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.16 | ColumnwtWebGraphThermHygroAlarmTcpText | read-write | mandatory | This text is sent in the TCP trap body. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.17 | ColumnwtWebGraphThermHygroAlarmClearMailSubject | read-write | mandatory | Subject line for alarm clear mail. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.18 | ColumnwtWebGraphThermHygroAlarmClearMailText | read-write | mandatory | Alarm clear mail text: <Tn> provides the current temperature; n = 1..8. <Z> provides the current time. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.19 | ColumnwtWebGraphThermHygroAlarmClearTrapText | read-write | mandatory | This text is sent in the trap body. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.20 | ColumnwtWebGraphThermHygroAlarmClearTcpText | read-write | mandatory | This text is sent in the TCP trap body. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.21 | ColumnwtWebGraphThermHygroAlarmDeltaTemp | read-write | mandatory | Maximum rate of change degrees/min with maximum 2 decimal places. Compared with the average of a period of 5 minutes. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.22 | ColumnwtWebGraphThermHygroAlarmRHMin | read-write | mandatory | Minimum rel. Humidity in percent with maximum 2 decimal places. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.23 | ColumnwtWebGraphThermHygroAlarmRHMax | read-write | mandatory | Maximum rel.Humidity in percent with maximum 2 decimal places. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.24 | ColumnwtWebGraphThermHygroAlarmRHHysteresis | read-write | mandatory | Hysterese rel. Humidity in percent with maximum 2 decimal places. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.25 | ColumnwtWebGraphThermHygroAlarmAHMin | read-write | mandatory | Minimum abs. Humidity in g/(m*m*m) with maximum 2 decimal places. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.26 | ColumnwtWebGraphThermHygroAlarmAHMax | read-write | mandatory | Maximum abs. Humidity in g/(m*m*m) with maximum 2 decimal places. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.27 | ColumnwtWebGraphThermHygroAlarmSyslogIpAddr | read-write | mandatory | IP address of the syslog server to which the Webio device should send syslog messages. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.28 | ColumnwtWebGraphThermHygroAlarmSyslogPort | read-write | mandatory | Port number of the syslog server to which the Webio device should send syslog messages. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.29 | ColumnwtWebGraphThermHygroAlarmSyslogText | read-write | mandatory | Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.30 | ColumnwtWebGraphThermHygroAlarmSyslogClearText | read-write | mandatory | Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.31 | ColumnwtWebGraphThermHygroAlarmFtpDataPort | read-write | mandatory | Local data port: 1..65535 or AUTO: the next free port will be assigned. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.32 | ColumnwtWebGraphThermHygroAlarmFtpFileName | read-write | mandatory | Name of the file including path informations. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.33 | ColumnwtWebGraphThermHygroAlarmFtpText | read-write | mandatory | Message text to store on the FTP server. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.34 | ColumnwtWebGraphThermHygroAlarmFtpClearText | read-write | mandatory | Alarm clear message to store on the FTP server. |
| 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.35 | ColumnwtWebGraphThermHygroAlarmFtpOptions | read-write | mandatory | Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unu… |
| 1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.36 | ColumnwtWebGraphThermHygroAlarmTimerCron | read-write | mandatory | This entry contains 5 space or tab seperated text fields for time trigger definition. Each field must match with the actual time to trigger a message, weekday … |
| 1.3.6.1.4.1.5040.1.2.9.3.2 | NodewtWebGraphThermHygroPorts | |||
| 1.3.6.1.4.1.5040.1.2.9.3.2.1 | TablewtWebGraphThermHygroPortTable | not-accessible | mandatory | List of settings depending on the sensor number. |
| 1.3.6.1.4.1.5040.1.2.9.3.2.1.1 | RowwtWebGraphThermHygroPortEntry | not-accessible | mandatory | Sensor parameters for the individual sensors. |
| 1.3.6.1.4.1.5040.1.2.9.3.2.1.1.1 | ColumnwtWebGraphThermHygroPortName | read-write | mandatory | Name of the sensor. |
| 1.3.6.1.4.1.5040.1.2.9.3.2.1.1.2 | ColumnwtWebGraphThermHygroPortText | read-write | mandatory | Description of the sensor. |
| 1.3.6.1.4.1.5040.1.2.9.3.2.1.1.3 | ColumnwtWebGraphThermHygroPortOffset1 | read-write | mandatory | Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 1. |
| 1.3.6.1.4.1.5040.1.2.9.3.2.1.1.4 | ColumnwtWebGraphThermHygroPortTemperature1 | read-write | mandatory | Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places. |
| 1.3.6.1.4.1.5040.1.2.9.3.2.1.1.5 | ColumnwtWebGraphThermHygroPortOffset2 | read-write | mandatory | Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 2. |
| 1.3.6.1.4.1.5040.1.2.9.3.2.1.1.6 | ColumnwtWebGraphThermHygroPortTemperature2 | read-write | mandatory | Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places. |
| 1.3.6.1.4.1.5040.1.2.9.3.2.1.1.7 | ColumnwtWebGraphThermHygroPortComment | read-write | mandatory | Offset calibration: informations of date, name of operator, reference devices. |
| 1.3.6.1.4.1.5040.1.2.9.3.2.1.1.8 | ColumnwtWebGraphThermHygroPortSensorSelect | read-write | mandatory | Binary coded options for sensor 1: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : PT100 Bit 1 : PT1000 (default) Bit 2-7: unused Binary coded… |
| 1.3.6.1.4.1.5040.1.2.9.3.3 | NodewtWebGraphThermHygroManufact | |||
| 1.3.6.1.4.1.5040.1.2.9.3.3.1 | ScalarwtWebGraphThermHygroMfName | read-write | mandatory | Manufacturer company name |
| 1.3.6.1.4.1.5040.1.2.9.3.3.2 | ScalarwtWebGraphThermHygroMfAddr | read-write | mandatory | Manufacturer address. |
| 1.3.6.1.4.1.5040.1.2.9.3.3.3 | ScalarwtWebGraphThermHygroMfHotline | read-write | mandatory | Manufacturer hotline. |
| 1.3.6.1.4.1.5040.1.2.9.3.3.4 | ScalarwtWebGraphThermHygroMfInternet | read-write | mandatory | Manufacturer Internet address. |
| 1.3.6.1.4.1.5040.1.2.9.3.3.5 | ScalarwtWebGraphThermHygroMfDeviceTyp | read-write | mandatory | Manufacturer device name (model number). |
| 1.3.6.1.4.1.5040.1.2.9.3.3.6 | ScalarwtWebGraphThermHygroMfOrderNo | read-write | mandatory | Manufacturer part number. |
| 1.3.6.1.4.1.5040.1.2.9.4 | NodewtWebGraphThermHygroDiag | |||
| 1.3.6.1.4.1.5040.1.2.9.4.1 | ScalarwtWebGraphThermHygroDiagErrorCount | read-only | mandatory | Number of entries in the error memory. |
| 1.3.6.1.4.1.5040.1.2.9.4.2 | ScalarwtWebGraphThermHygroDiagBinaryError | read-only | mandatory | Error causes coded bit-by-bit. |
| 1.3.6.1.4.1.5040.1.2.9.4.3 | ScalarwtWebGraphThermHygroDiagErrorIndex | read-write | mandatory | The value of this variable is used as an index to read an error massege from wtWebGraphThermHygroDiagErrorMessage. Errors are numbered from 1 to wtWebGraphTher… |
| 1.3.6.1.4.1.5040.1.2.9.4.4 | ScalarwtWebGraphThermHygroDiagErrorMessage | read-only | mandatory | Using wtWebGraphThermHygroDiagErrorIndex as an index, the appropriate message is available. |
| 1.3.6.1.4.1.5040.1.2.9.4.5 | ScalarwtWebGraphThermHygroDiagErrorClear | write-only | mandatory | Writing 1 into this variable clears all diagnosis messages. |
| 1.3.6.1.4.1.5040.1.2.9.31 | NodewtWebGraphThermHygroAlert1 | This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled. | ||
| 1.3.6.1.4.1.5040.1.2.9.32 | NodewtWebGraphThermHygroAlert2 | This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled. | ||
| 1.3.6.1.4.1.5040.1.2.9.33 | NodewtWebGraphThermHygroAlert3 | This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled. | ||
| 1.3.6.1.4.1.5040.1.2.9.34 | NodewtWebGraphThermHygroAlert4 | This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled. | ||
| 1.3.6.1.4.1.5040.1.2.9.35 | NodewtWebGraphThermHygroAlert5 | This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled. | ||
| 1.3.6.1.4.1.5040.1.2.9.36 | NodewtWebGraphThermHygroAlert6 | This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled. | ||
| 1.3.6.1.4.1.5040.1.2.9.37 | NodewtWebGraphThermHygroAlert7 | This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled. | ||
| 1.3.6.1.4.1.5040.1.2.9.38 | NodewtWebGraphThermHygroAlert8 | This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled. | ||
| 1.3.6.1.4.1.5040.1.2.9.91 | NodewtWebGraphThermHygroAlert9 | This SNMP trap is generated when Alarm 1 was cleared, SNMP trap enable is set and SNMP is enabled. | ||
| 1.3.6.1.4.1.5040.1.2.9.92 | NodewtWebGraphThermHygroAlert10 | This SNMP trap is generated when Alarm 2 was cleared, SNMP trap enable is set and SNMP is enabled. | ||
| 1.3.6.1.4.1.5040.1.2.9.93 | NodewtWebGraphThermHygroAlert11 | This SNMP trap is generated when Alarm 3 was cleared, SNMP trap enable is set and SNMP is enabled. | ||
| 1.3.6.1.4.1.5040.1.2.9.94 | NodewtWebGraphThermHygroAlert12 | This SNMP trap is generated when Alarm 4 was cleared, SNMP trap enable is set and SNMP is enabled. | ||
| 1.3.6.1.4.1.5040.1.2.9.95 | NodewtWebGraphThermHygroAlert13 | This SNMP trap is generated when Alarm 5 was cleared, SNMP trap enable is set and SNMP is enabled. | ||
| 1.3.6.1.4.1.5040.1.2.9.96 | NodewtWebGraphThermHygroAlert14 | This SNMP trap is generated when Alarm 6 was cleared, SNMP trap enable is set and SNMP is enabled. | ||
| 1.3.6.1.4.1.5040.1.2.9.97 | NodewtWebGraphThermHygroAlert15 | This SNMP trap is generated when Alarm 7 was cleared, SNMP trap enable is set and SNMP is enabled. | ||
| 1.3.6.1.4.1.5040.1.2.9.98 | NodewtWebGraphThermHygroAlert16 | This SNMP trap is generated when Alarm 8 was cleared, SNMP trap enable is set and SNMP is enabled. | ||
| 1.3.6.1.4.1.5040.1.2.9.110 | NodewtWebGraphThermHygroAlertDiag | This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled. |