WebGraph-Thermo-Hygrometer-US-MIB
269 objects
No module-level DESCRIPTION found.
Imported Objects
| RFC-1212 | OBJECT-TYPE |
| RFC-1215 | TRAP-TYPE |
| RFC1155-SMI | enterprises IpAddress NetworkAddress TimeTicks |
| RFC1213-MIB | DisplayString PhysAddress |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.5040 | Nodewut | |||
| 1.3.6.1.4.1.5040.1 | NodewtComServer | |||
| 1.3.6.1.4.1.5040.1.2 | NodewtWebio | |||
| 1.3.6.1.4.1.5040.1.2.42 | NodewtWebGraphThermoHygro | |||
| 1.3.6.1.4.1.5040.1.2.42.1 | NodewtWebGraphThermoHygroTemp | |||
| 1.3.6.1.4.1.5040.1.2.42.1.1 | ScalarwtWebGraphThermoHygroSensors | read-only | mandatory | Number of sensors |
| 1.3.6.1.4.1.5040.1.2.42.1.2 | TablewtWebGraphThermoHygroSensorTable | not-accessible | mandatory | List of sensors. |
| 1.3.6.1.4.1.5040.1.2.42.1.2.1 | RowwtWebGraphThermoHygroSensorEntry | not-accessible | mandatory | List of sensor numbers. |
| 1.3.6.1.4.1.5040.1.2.42.1.2.1.1 | ColumnwtWebGraphThermoHygroSensorNo | read-only | mandatory | Sensor number. |
| 1.3.6.1.4.1.5040.1.2.42.1.3 | TablewtWebGraphThermoHygroTempValueTable | not-accessible | mandatory | List of measurement values corresponding to the channel numbers. |
| 1.3.6.1.4.1.5040.1.2.42.1.3.1 | RowwtWebGraphThermoHygroTempValueEntry | not-accessible | mandatory | Measurement values of the sensors. |
| 1.3.6.1.4.1.5040.1.2.42.1.3.1.1 | ColumnwtWebGraphThermoHygroTempValue | read-only | mandatory | Measurement value of the sensor, ASCII, 5 characters in length. |
| 1.3.6.1.4.1.5040.1.2.42.1.4 | TablewtWebGraphThermoHygroBinaryTempValueTable | not-accessible | mandatory | List of binary measurement values corresponding to the channel numbers. |
| 1.3.6.1.4.1.5040.1.2.42.1.4.1 | RowwtWebGraphThermoHygroBinaryTempValueEntry | not-accessible | mandatory | Binary measurement values of the sensors. |
| 1.3.6.1.4.1.5040.1.2.42.1.4.1.1 | ColumnwtWebGraphThermoHygroBinaryTempValue | read-only | mandatory | Binary measurement value of the sensor in 1/10 degrees Celsius or 1/10 per cent, signed number, 0x4FFF6 indicates an invalid measured value. |
| 1.3.6.1.4.1.5040.1.2.42.1.8 | TablewtWebGraphThermoHygroTempValuePktTable | not-accessible | mandatory | List of measurement values corresponding to the channel numbers. |
| 1.3.6.1.4.1.5040.1.2.42.1.8.1 | RowwtWebGraphThermoHygroTempValuePktEntry | not-accessible | mandatory | Measurement values of the sensors. |
| 1.3.6.1.4.1.5040.1.2.42.1.8.1.1 | ColumnwtWebGraphThermoHygroTempValuePkt | read-only | mandatory | Measurement value of the sensor, ASCII, 5 characters in length, delimeter is decimal point. |
| 1.3.6.1.4.1.5040.1.2.42.2 | NodewtWebGraphThermoHygroSessCntrl | |||
| 1.3.6.1.4.1.5040.1.2.42.2.1 | ScalarwtWebGraphThermoHygroSessCntrlPassword | read-write | mandatory | Entering this password opens a session which is ended by writing a 1 to wtWebGraphThermoHygroSessCntrlLogout. When read this variable provides a string of leng… |
| 1.3.6.1.4.1.5040.1.2.42.2.2 | ScalarwtWebGraphThermoHygroSessCntrlConfigMode | read-only | mandatory | When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is… |
| 1.3.6.1.4.1.5040.1.2.42.2.3 | ScalarwtWebGraphThermoHygroSessCntrlLogout | read-write | mandatory | If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters ar… |
| 1.3.6.1.4.1.5040.1.2.42.2.4 | ScalarwtWebGraphThermoHygroSessCntrlAdminPassword | read-write | mandatory | This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid p… |
| 1.3.6.1.4.1.5040.1.2.42.2.5 | ScalarwtWebGraphThermoHygroSessCntrlConfigPassword | read-write | mandatory | This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was ass… |
| 1.3.6.1.4.1.5040.1.2.42.3 | NodewtWebGraphThermoHygroConfig | |||
| 1.3.6.1.4.1.5040.1.2.42.3.1 | NodewtWebGraphThermoHygroDevice | |||
| 1.3.6.1.4.1.5040.1.2.42.3.1.1 | NodewtWebGraphThermoHygroText | |||
| 1.3.6.1.4.1.5040.1.2.42.3.1.1.1 | ScalarwtWebGraphThermoHygroDeviceName | read-write | mandatory | Name of the Webio, which is user definable. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.1.2 | ScalarwtWebGraphThermoHygroDeviceText | read-write | mandatory | Description of the Webio, which is user definable. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.1.3 | ScalarwtWebGraphThermoHygroDeviceLocation | read-write | mandatory | Description of the location of the Webio, which is user definable. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.1.4 | ScalarwtWebGraphThermoHygroDeviceContact | read-write | mandatory | Contact address of the system operator of the Webio, which is user definable. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.2 | NodewtWebGraphThermoHygroTimeDate | |||
| 1.3.6.1.4.1.5040.1.2.42.3.1.2.1 | NodewtWebGraphThermoHygroTimeZone | |||
| 1.3.6.1.4.1.5040.1.2.42.3.1.2.1.1 | ScalarwtWebGraphThermoHygroTzOffsetHrs | read-write | mandatory | Offset hours for the time zone (winter time) with respect to UTC. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.2.1.2 | ScalarwtWebGraphThermoHygroTzOffsetMin | read-write | mandatory | Offset minutes for the time zone (winter time) with respect to UTC. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.2.1.3 | ScalarwtWebGraphThermoHygroTzEnable | read-write | mandatory | Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone |
| 1.3.6.1.4.1.5040.1.2.42.3.1.2.1.4 | ScalarwtWebGraphThermoHygroStTzOffsetHrs | read-write | mandatory | Offset hours of the time zone (summer time) with respect to UTC. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.2.1.5 | ScalarwtWebGraphThermoHygroStTzOffsetMin | read-write | mandatory | Offset minutes of the time zone (summer time) with respect to UTC. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.2.1.6 | ScalarwtWebGraphThermoHygroStTzEnable | read-write | mandatory | Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime |
| 1.3.6.1.4.1.5040.1.2.42.3.1.2.1.7 | ScalarwtWebGraphThermoHygroStTzStartMonth | read-write | mandatory | Month in which the change is made from winter time to summer time. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.2.1.8 | ScalarwtWebGraphThermoHygroStTzStartMode | read-write | mandatory | Mode of the day of the week for which the change is made from winter time to summer time. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.2.1.9 | ScalarwtWebGraphThermoHygroStTzStartWday | read-write | mandatory | Day of the week on which the change is made from winter time to summer time |
| 1.3.6.1.4.1.5040.1.2.42.3.1.2.1.10 | ScalarwtWebGraphThermoHygroStTzStartHrs | read-write | mandatory | Hour in which the time zone is changed from winter to summer time with respect to UTC. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.2.1.11 | ScalarwtWebGraphThermoHygroStTzStartMin | read-write | mandatory | Minute in which the time zone is changed from winter to summer time with respect to UTC. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.2.1.12 | ScalarwtWebGraphThermoHygroStTzStopMonth | read-write | mandatory | Month in which the change is made from summer time to winter time. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.2.1.13 | ScalarwtWebGraphThermoHygroStTzStopMode | read-write | mandatory | Mode of the week day on which the change is made from summer time to winter time. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.2.1.14 | ScalarwtWebGraphThermoHygroStTzStopWday | read-write | mandatory | Day of the week on which the change is made from summer time to winter time. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.2.1.15 | ScalarwtWebGraphThermoHygroStTzStopHrs | read-write | mandatory | Hour at which the time zone is changed from summer to winter time with respect to UTC. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.2.1.16 | ScalarwtWebGraphThermoHygroStTzStopMin | read-write | mandatory | Minute at which the time zone is changed from summer to winter time with respect to UTC. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.2.2 | NodewtWebGraphThermoHygroTimeServer | |||
| 1.3.6.1.4.1.5040.1.2.42.3.1.2.2.1 | ScalarwtWebGraphThermoHygroTimeServer1 | read-write | mandatory | IP address or name of the 1st time server in ASCII |
| 1.3.6.1.4.1.5040.1.2.42.3.1.2.2.2 | ScalarwtWebGraphThermoHygroTimeServer2 | read-write | mandatory | IP address or name of the 2nd time server in ASCII |
| 1.3.6.1.4.1.5040.1.2.42.3.1.2.2.3 | ScalarwtWebGraphThermoHygroTsEnable | read-write | mandatory | Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server |
| 1.3.6.1.4.1.5040.1.2.42.3.1.2.2.4 | ScalarwtWebGraphThermoHygroTsSyncTime | read-write | mandatory | Daily synchronisation time with the time server (hour: 0-23). |
| 1.3.6.1.4.1.5040.1.2.42.3.1.2.3 | NodewtWebGraphThermoHygroDeviceClock | |||
| 1.3.6.1.4.1.5040.1.2.42.3.1.2.3.1 | ScalarwtWebGraphThermoHygroClockHrs | read-write | mandatory | Clock hours taking into account the time zone settings. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.2.3.2 | ScalarwtWebGraphThermoHygroClockMin | read-write | mandatory | Clock minutes taking into account the time zone settings. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.2.3.3 | ScalarwtWebGraphThermoHygroClockDay | read-write | mandatory | Date: Day of the month, taking into account the time zone settings. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.2.3.4 | ScalarwtWebGraphThermoHygroClockMonth | read-write | mandatory | Date: Month, taking into account the time zone settings. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.2.3.5 | ScalarwtWebGraphThermoHygroClockYear | read-write | mandatory | Date: Year, taking into account the time zone settings. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3 | NodewtWebGraphThermoHygroBasic | |||
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.1 | NodewtWebGraphThermoHygroNetwork | |||
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.1.1 | ScalarwtWebGraphThermoHygroIpAddress | read-write | mandatory | IP address of the Webio |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.1.2 | ScalarwtWebGraphThermoHygroSubnetMask | read-write | mandatory | Subnet mask of the Webio |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.1.3 | ScalarwtWebGraphThermoHygroGateway | read-write | mandatory | Gateway of the Webio |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.1.4 | ScalarwtWebGraphThermoHygroDnsServer1 | read-write | mandatory | IP address of the 1st DNS server in ASCII |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.1.5 | ScalarwtWebGraphThermoHygroDnsServer2 | read-write | mandatory | IP address of the 2nd DNS server in ASCII |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.1.6 | ScalarwtWebGraphThermoHygroAddConfig | read-write | mandatory | Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: DHCP disable Bit 0: BOOTP disable |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.2 | NodewtWebGraphThermoHygroHTTP | |||
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.2.1 | ScalarwtWebGraphThermoHygroStartup | read-write | mandatory | Binary coded start page: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: Index.htm Bit 2: Home.htm Bit 3: User.htm Only one page may be selecte… |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.2.2 | ScalarwtWebGraphThermoHygroGetHeaderEnable | read-write | mandatory | If these bits are set, every answer of a short form GET question will be lead by the IP-address and name of the device and/or a HTTP header: Octet 1: unused Oc… |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.2.3 | ScalarwtWebGraphThermoHygroHttpPort | read-write | mandatory | Definition of the standard HTML port (Default: 80). |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.3 | NodewtWebGraphThermoHygroMail | |||
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.3.1 | ScalarwtWebGraphThermoHygroMailAdName | read-write | mandatory | Device name for mail administration. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.3.2 | ScalarwtWebGraphThermoHygroMailReply | read-write | mandatory | Reply address for the mail server. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.3.3 | ScalarwtWebGraphThermoHygroMailServer | read-write | mandatory | Name or IP address of the mail server. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.3.4 | ScalarwtWebioAn1MailEnable | read-write | mandatory | Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.3.5 | ScalarwtWebGraphThermoHygroMailAuthentication | read-write | mandatory | Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: u… |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.3.6 | ScalarwtWebGraphThermoHygroMailAuthUser | read-write | mandatory | Name of the user to be authenticated. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.3.7 | ScalarwtWebGraphThermoHygroMailAuthPassword | read-write | mandatory | Authentication password. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.3.8 | ScalarwtWebGraphThermoHygroMailPop3Server | read-write | mandatory | Name or Ip-address of the POP3 Servers. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.4 | NodewtWebGraphThermoHygroSNMP | |||
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.4.1 | ScalarwtWebGraphThermoHygroSnmpCommunityStringRead | read-write | mandatory | Community string read only |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.4.2 | ScalarwtWebGraphThermoHygroSnmpCommunityStringReadWrite | read-write | mandatory | Community string read / write |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.4.3 | ScalarwtWebGraphThermoHygroSystemTrapManagerIP | read-write | mandatory | Name or IP address of the TCP server which accepts the system trap. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.4.4 | ScalarwtWebGraphThermoHygroSystemTrapEnable | read-write | mandatory | Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2-7: unused |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.4.5 | ScalarwtWebGraphThermoHygroSnmpEnable | read-write | mandatory | Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compare… |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.4.6 | ScalarwtWebGraphThermoHygroSnmpCommunityStringTrap | read-write | mandatory | Community string send within traps. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.4.7 | ScalarwtWebGraphThermoHygroSnmpSystemTrapManagerPort | read-write | mandatory | Port number of the TCP server which accepts the system trap. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.5 | NodewtWebGraphThermoHygroUDP | |||
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.5.1 | ScalarwtWebGraphThermoHygroUdpPort | read-write | mandatory | Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.5.2 | ScalarwtWebGraphThermoHygroUdpEnable | read-write | mandatory | Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.6 | NodewtWebGraphThermoHygroSyslog | |||
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.6.1 | ScalarwtWebGraphThermoHygroSyslogServerIP | read-write | mandatory | Name or IP address of the Syslog server, which accepts the Syslog messgaes. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.6.2 | ScalarwtWebGraphThermoHygroSyslogServerPort | read-write | mandatory | Portnumber of the Syslog servers, default 514. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.6.3 | ScalarwtWebGraphThermoHygroSyslogSystemMessagesEnable | read-write | mandatory | Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.6.4 | ScalarwtWebGraphThermoHygroSyslogEnable | read-write | mandatory | Set bit 0to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.7 | NodewtWebGraphThermoHygroFTP | |||
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.7.1 | ScalarwtWebGraphThermoHygroFTPServerIP | read-write | mandatory | Name or IP address of the FTP server, which accepts the FTP messages. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.7.2 | ScalarwtWebGraphThermoHygroFTPServerControlPort | read-write | mandatory | Portnumber of the control port of the FTP server, default 21. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.7.3 | ScalarwtWebGraphThermoHygroFTPUserName | read-write | mandatory | FTP Loggin: user name. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.7.4 | ScalarwtWebGraphThermoHygroFTPPassword | read-write | mandatory | FTP Loggin: user password. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.7.5 | ScalarwtWebGraphThermoHygroFTPAccount | read-write | mandatory | FTP Loggin: name of account. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.7.6 | ScalarwtWebGraphThermoHygroFTPOption | read-write | mandatory | Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit … |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.7.7 | ScalarwtWebGraphThermoHygroFTPEnable | read-write | mandatory | Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.8 | NodewtWebGraphThermoHygroRSS | |||
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.8.1 | ScalarwtWebGraphThermoHygroRSSChannelTitle | read-write | mandatory | Name of the RSS Feed. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.8.2 | ScalarwtWebGraphThermoHygroRSSChannelLink | read-write | mandatory | Link of the RSS Feed. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.8.3 | ScalarwtWebGraphThermoHygroRSSChannelDescription | read-write | mandatory | Description of the RSS Feed. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.8.4 | ScalarwtWebGraphThermoHygroRSSChannelImage | read-write | mandatory | Link of a picture, which will be shown at the headline of the output window. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.8.5 | ScalarwtWebGraphThermoHygroRSSChannelImageTitle | read-write | mandatory | Alias Name of the picture. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.8.6 | ScalarwtWebGraphThermoHygroRSSChannelImageLink | read-write | mandatory | Link, which can be selected by clicking on the picture. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.8.7 | ScalarwtWebGraphThermoHygroRSSChannelItemTitle | read-write | mandatory | Title of the RSS Feed. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.8.8 | ScalarwtWebGraphThermoHygroRSSChannelItemLink | read-write | mandatory | Link of the RSS Feed. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.8.9 | ScalarwtWebGraphThermoHygroRSSChannelItemDescription | read-write | mandatory | Text of the RSS Feed. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.8.10 | ScalarwtWebGraphThermoHygroRSSChannelItemQuantity | read-write | mandatory | Number of lines. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.9 | NodewtWebGraphThermoHygroLanguage | |||
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.9.1 | ScalarwtWebGraphThermoHygroLanguageSelect | read-write | mandatory | Sprachauswahl: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 2-7: ungenutzt Bit 1 : Englisch Bit 0 : Deutsch |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.12 | NodewtWebGraphThermoHygroMQTT | |||
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.12.1 | ScalarwtWebGraphThermoHygroMQTTEnable | read-write | mandatory | Bit 7 schaltet MQTT frei: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0-6: ungenutzt Bit 7 : MQTT enable |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.12.2 | ScalarwtWebGraphThermoHygroMQTTBrockerIP | read-write | mandatory | Name or IP-address of the MQTT-Server. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.12.3 | ScalarwtWebGraphThermoHygroMQTTUserName | read-write | mandatory | MQTT login user name. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.12.4 | ScalarwtWebGraphThermoHygroMQTTPassword | read-write | mandatory | MQTT login password. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.12.5 | ScalarwtWebGraphThermoHygroMQTTLocalPort | read-write | mandatory | Local port number. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.12.6 | ScalarwtWebGraphThermoHygroMQTTBrokerServerPort | read-write | mandatory | MQTT Server port number. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.12.7 | ScalarwtWebGraphThermoHygroMQTTInterval | read-write | mandatory | Ping intervall, if no data has to be send: time in seconds. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.12.8 | ScalarwtWebGraphThermoHygroMQTTLastWillEnable | read-write | mandatory | Bit 0 activate MQTT LastWill message: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : MQTT Last will enable |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.12.9 | ScalarwtWebGraphThermoHygroMQTTLastWillTopic | read-write | mandatory | MQTT Last Will Topic. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.12.10 | ScalarwtWebGraphThermoHygroMQTTLastWillMsg | read-write | mandatory | MQTT Last Will message. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.12.11 | ScalarwtWebGraphThermoHygroMQTTLastWillQoS | read-write | mandatory | Binary coded MQTT Publish QoS: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: QoS 0 Bit 1: QoS 1 Bit 2: QoS 2 Bit 3-7:unused |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.12.12 | ScalarwtWebGraphThermoHygroMQTTLastWillRetain | read-write | mandatory | Binary coded MQTT Publish Retain properties: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : retain enable Bit 1-7 : unused |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.12.13 | ScalarwtWebGraphThermoHygroMQTTLastWillConnectEnable | read-write | mandatory | Bit 0 activate MQTT LastWill Connect message: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : MQTT Last will connect message e… |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.12.14 | ScalarwtWebGraphThermoHygroMQTTLastWillConnectMsg | read-write | mandatory | MQTT Last Will Connect message will be send with the QoS and Retain settings of the LastWill message. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.13 | NodewtWebGraphThermoHygroREST | |||
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.13.1 | ScalarwtWebGraphThermoHygroRESTEnable | read-write | mandatory | Bit 0 activates REST : Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : REST enable |
| 1.3.6.1.4.1.5040.1.2.42.3.1.3.13.2 | ScalarwtWebGraphThermoHygroRESTDigestAuthEnable | read-write | mandatory | Bit 0 activates Digest-Authentification: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Digest Auth enable |
| 1.3.6.1.4.1.5040.1.2.42.3.1.4 | NodewtWebGraphThermoHygroDatalogger | |||
| 1.3.6.1.4.1.5040.1.2.42.3.1.4.1 | ScalarwtWebGraphThermoHygroLoggerTimebase | read-write | mandatory | Time base of the data logger |
| 1.3.6.1.4.1.5040.1.2.42.3.1.4.2 | ScalarwtWebGraphThermoHygroLoggerSensorSel | read-write | mandatory | Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2-7: unused |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5 | NodewtWebGraphThermoHygroAlarm | |||
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.1 | ScalarwtWebGraphThermoHygroAlarmCount | read-only | mandatory | Number of independent alarms. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.2 | TablewtWebGraphThermoHygroAlarmIfTable | not-accessible | mandatory | List of alarm indices. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.2.1 | RowwtWebGraphThermoHygroAlarmIfEntry | not-accessible | mandatory | Numbers of the alarms. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.2.1.1 | ColumnwtWebGraphThermoHygroAlarmNo | read-only | mandatory | Alarm number. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3 | TablewtWebGraphThermoHygroAlarmTable | not-accessible | mandatory | List of settings depending on the alarm number. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1 | RowwtWebGraphThermoHygroAlarmEntry | not-accessible | mandatory | Alarm parameters of the individual alarms. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.1 | ColumnwtWebGraphThermoHygroAlarmTrigger | read-write | mandatory | Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: Bit 0: Timer Bit 1: ColdStart Bit 2: WarmStart Octet 4: Bit 0: Sensor 1 Bit 1: Sensor… |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.2 | ColumnwtWebGraphThermoHygroAlarmMin | read-write | mandatory | Minimum temperature in degrees with maximum 2 decimal places. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.3 | ColumnwtWebGraphThermoHygroAlarmMax | read-write | mandatory | Maximum temperature in degrees with maximum 2 decimal places. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.4 | ColumnwtWebGraphThermoHygroAlarmHysteresis | read-write | mandatory | Temperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.) , in degrees with maximum 2 decimal places. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.5 | ColumnwtWebGraphThermoHygroAlarmDelay | read-write | mandatory | Alarm will be delayed by setting this time while stable alarm condition occur (time in minutes). |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.6 | ColumnwtWebGraphThermoHygroAlarmInterval | read-write | mandatory | Send interval for alarm messages. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.7 | ColumnwtWebGraphThermoHygroAlarmEnable | read-write | mandatory | Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: TCP Client enable |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.8 | ColumnwtWebGraphThermoHygroAlarmEMailAddr | read-write | mandatory | E-Mail address for sending the alarm mail to. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.9 | ColumnwtWebGraphThermoHygroAlarmMailSubject | read-write | mandatory | Subject line for alarm mail. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.10 | ColumnwtWebGraphThermoHygroAlarmMailText | read-write | mandatory | Alarm mail text: <Tn> provides the current temperature; n = 1..8. <Z> provides the current time. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.11 | ColumnwtWebGraphThermoHygroAlarmManagerIP | read-write | mandatory | Name or IP address of the SNMP Manager which accepts the trap. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.12 | ColumnwtWebGraphThermoHygroAlarmTrapText | read-write | mandatory | This text is sent in the trap body. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.13 | ColumnwtWebGraphThermoHygroAlarmMailOptions | read-write | mandatory | Binary coded options: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Attach Thermo.csv Enable Bit 1 : CSV-Data_since_last_report Bit 2-7: unu… |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.14 | ColumnwtWebGraphThermoHygroAlarmTcpIpAddr | read-write | mandatory | Name or IP address of the TCP server which accepts the trap. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.15 | ColumnwtWebGraphThermoHygroAlarmTcpPort | read-write | mandatory | Port number of the TCP server which accepts the trap. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.16 | ColumnwtWebGraphThermoHygroAlarmTcpText | read-write | mandatory | This text is sent in the TCP trap body. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.17 | ColumnwtWebGraphThermoHygroAlarmClearMailSubject | read-write | mandatory | Subject line for alarm clear mail. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.18 | ColumnwtWebGraphThermoHygroAlarmClearMailText | read-write | mandatory | Alarm clear mail text: <Tn> provides the current temperature; n = 1..8. <Z> provides the current time. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.19 | ColumnwtWebGraphThermoHygroAlarmClearTrapText | read-write | mandatory | This text is sent in the trap body. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.20 | ColumnwtWebGraphThermoHygroAlarmClearTcpText | read-write | mandatory | This text is sent in the TCP trap body. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.21 | ColumnwtWebGraphThermoHygroAlarmDeltaTemp | read-write | mandatory | Maximum rate of change degrees/min with maximum 2 decimal places. Compared with the average of a period of 5 minutes. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.22 | ColumnwtWebGraphThermoHygroAlarmRHMin | read-write | mandatory | Minimum rel. Humidity in percent with maximum 2 decimal places. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.23 | ColumnwtWebGraphThermoHygroAlarmRHMax | read-write | mandatory | Maximum rel.Humidity in percent with maximum 2 decimal places. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.24 | ColumnwtWebGraphThermoHygroAlarmRHHysteresis | read-write | mandatory | Hysterese rel. Humidity in percent with maximum 2 decimal places. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.25 | ColumnwtWebGraphThermoHygroAlarmAHMin | read-write | mandatory | Minimum abs. Humidity in g/(m*m*m) with maximum 2 decimal places. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.26 | ColumnwtWebGraphThermoHygroAlarmAHMax | read-write | mandatory | Maximum abs. Humidity in g/(m*m*m) with maximum 2 decimal places. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.27 | ColumnwtWebGraphThermoHygroAlarmSyslogIpAddr | read-write | mandatory | IP address of the syslog server to which the Webio device should send syslog messages. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.28 | ColumnwtWebGraphThermoHygroAlarmSyslogPort | read-write | mandatory | Port number of the syslog server to which the Webio device should send syslog messages. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.29 | ColumnwtWebGraphThermoHygroAlarmSyslogText | read-write | mandatory | Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.30 | ColumnwtWebGraphThermoHygroAlarmSyslogClearText | read-write | mandatory | Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.31 | ColumnwtWebGraphThermoHygroAlarmFtpDataPort | read-write | mandatory | Local data port: 1..65535 or AUTO: the next free port will be assigned. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.32 | ColumnwtWebGraphThermoHygroAlarmFtpFileName | read-write | mandatory | Name of the file including path informations. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.33 | ColumnwtWebGraphThermoHygroAlarmFtpText | read-write | mandatory | Message text to store on the FTP server. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.34 | ColumnwtWebGraphThermoHygroAlarmFtpClearText | read-write | mandatory | Alarm clear message to store on the FTP server. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.35 | ColumnwtWebGraphThermoHygroAlarmFtpOption | read-write | mandatory | Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unu… |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.36 | ColumnwtWebGraphThermoHygroAlarmTimerCron | read-write | mandatory | This entry contains 5 space or tab seperated text fields for time trigger definition. Each field must match with the actual time to trigger a message, weekday … |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.39 | ColumnwtWebGraphThermoHygroAlarmName | read-write | mandatory | Alert name |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.40 | ColumnwtWebGraphThermoHygroAlarmActive | read-write | mandatory | Alert active 1 = ON 0 = OFF |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.61 | ColumnwtWebGraphThermoHygroAlarmHttpReqAuthEnable | read-write | mandatory | Binary coded options, select only one option at the same time: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 1-7: unused Bit 0 : HHTP Request Au… |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.62 | ColumnwtWebGraphThermoHygroAlarmHttpReqAuthUser | read-write | mandatory | HTTP Request: User |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.63 | ColumnwtWebGraphThermoHygroAlarmHttpReqAuthPassword | read-write | mandatory | HTTP Request: Password |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.64 | ColumnwtWebGraphThermoHygroAlarmHttpReqSetUrl | read-write | mandatory | HTTP Request: Set URL |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.65 | ColumnwtWebGraphThermoHygroAlarmHttpReqClearUrl | read-write | mandatory | HTTP Request: Clear URL |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.66 | ColumnwtWebGraphThermoHygroAlarmHttpReqServerPort | read-write | mandatory | HTTP Request: Server Port |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.67 | ColumnwtWebGraphThermoHygroAlarmMqttTopicPath | read-write | mandatory | MQTT Publish: Topic path |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.68 | ColumnwtWebGraphThermoHygroAlarmMqttTopicSetTopic | read-write | mandatory | MQTT Publish: Topic SET message |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.69 | ColumnwtWebGraphThermoHygroAlarmMqttTopicClear | read-write | mandatory | MQTT Publish: Topic CLEAR message |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.70 | ColumnwtWebGraphThermoHygroAlarmSensorLostSelection | read-write | mandatory | Binary coded options: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 2-7: unused Bit 1 : Sensor 1 Bit 0 : Sensor 0 |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.71 | ColumnwtWebGraphThermoHygroAlarmLimitWindow | read-write | mandatory | If window type is INSIDE the alarm is genereted when the temperature is greater minumum value and lower than maximum value. If window type is OUTSIDE the alarm… |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.76 | ColumnwtWebGraphThermoHygroAlarmSnmpManagerPort | read-write | mandatory | Port number of the SNMP Manager to which the Webio device should send SNMP traps. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.77 | ColumnwtWebGraphThermoHygroAlarmMqttQoS | read-write | mandatory | Binary coded value: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: QoS 0 Bit 1: QoS 1 Bit 2: QoS 2 Bit 3-7:unused |
| 1.3.6.1.4.1.5040.1.2.42.3.1.5.3.1.78 | ColumnwtWebGraphThermoHygroAlarmMqttRetain | read-write | mandatory | Binary coded value: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : retain enable Bit 1-7 : unused |
| 1.3.6.1.4.1.5040.1.2.42.3.1.6 | NodewtWebGraphThermoHygroGraphics | |||
| 1.3.6.1.4.1.5040.1.2.42.3.1.6.1 | NodewtWebGraphThermoHygroGraphicsBase | |||
| 1.3.6.1.4.1.5040.1.2.42.3.1.6.1.1 | ScalarwtWebGraphThermoHygroGraphicsBaseEnable | read-write | mandatory | Defines the viewing options of the graphic: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Auto scroll enable Bit 1 : Show table Bit 2 : Show… |
| 1.3.6.1.4.1.5040.1.2.42.3.1.6.1.2 | ScalarwtWebGraphThermoHygroGraphicsBaseWidth | read-write | mandatory | Defines the width of the graphic in pixels. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.6.1.3 | ScalarwtWebGraphThermoHygroGraphicsBaseHeight | read-write | mandatory | Defines the height of the graphic in pixels. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.6.1.4 | ScalarwtWebGraphThermoHygroGraphicsBaseFrameColor | read-write | mandatory | Frame color definition in RGB. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.6.1.5 | ScalarwtWebGraphThermoHygroGraphicsBaseBackgroundColor | read-write | mandatory | Background color definition in RGB. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.6.1.6 | ScalarwtWebGraphThermoHygroGraphicsBasePollingrate | read-write | mandatory | Defines the pollingrate in seconds, which defines the refreshing intervall of the graphic. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.6.2 | NodewtWebGraphThermoHygroGraphicsSelect | |||
| 1.3.6.1.4.1.5040.1.2.42.3.1.6.2.1 | ScalarwtWebGraphThermoHygroGraphicsSelectDisplaySensorSel | read-write | mandatory | Binary coded sensor selection: only selected sensors will be shown in the graphical presentation: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit … |
| 1.3.6.1.4.1.5040.1.2.42.3.1.6.2.2 | ScalarwtWebGraphThermoHygroGraphicsSelectDisplayShowExtrem | read-write | mandatory | Binary coded sensor selection: only selected sensors will be shown with minima and maxima: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sens… |
| 1.3.6.1.4.1.5040.1.2.42.3.1.6.2.3 | TablewtWebGraphThermoHygroSensorColorTable | not-accessible | mandatory | List of sensor colors for the praphical presentation. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.6.2.3.1 | RowwtWebGraphThermoHygroSensorColorEntry | not-accessible | mandatory | Numbers of the sensors. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.6.2.3.1.1 | ColumnwtWebGraphThermoHygroGraphicsSensorColor | read-write | mandatory | Color of the sensors at the praphical presention. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.6.2.3.1.2 | ColumnwtWebGraphThermoHygroGraphicsSelectScale | read-write | mandatory | Assignes one of 4 scales to a sensor: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Use Scale 1 Bit 1 : Use Scale 2 Bit 2-7: unused |
| 1.3.6.1.4.1.5040.1.2.42.3.1.6.3 | NodewtWebGraphThermoHygroGraphicsScale | |||
| 1.3.6.1.4.1.5040.1.2.42.3.1.6.3.1 | ScalarwtWebGraphThermoHygroGraphicsScaleAutoScaleEnable | read-write | mandatory | Select the Auto Scale Mode: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Scale 1 Auto scale enable Bit 1 : Scale 2 Auto scale enable Bit 2-… |
| 1.3.6.1.4.1.5040.1.2.42.3.1.6.3.2 | ScalarwtWebGraphThermoHygroGraphicsScaleAutoFitEnable | read-write | mandatory | Select the Auto Fit Mode:: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Scale 1 Auto fit enable Bit 1 : Scale 2 Auto fit enable Bit 2-7: un… |
| 1.3.6.1.4.1.5040.1.2.42.3.1.6.3.3 | ScalarwtWebGraphThermoHygroGraphicsScale1Min | read-only | mandatory | Scale 1: Minimum. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.6.3.4 | ScalarwtWebGraphThermoHygroGraphicsScale2Min | read-only | mandatory | Scale 2: Minimum. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.6.3.5 | ScalarwtWebGraphThermoHygroGraphicsScale3Min | read-only | mandatory | Scale 3: Minimum. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.6.3.6 | ScalarwtWebGraphThermoHygroGraphicsScale4Min | read-only | mandatory | Scale 4: Minimum. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.6.3.7 | ScalarwtWebGraphThermoHygroGraphicsScale1Max | read-only | mandatory | Scale 1: Maximum. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.6.3.8 | ScalarwtWebGraphThermoHygroGraphicsScale2Max | read-only | mandatory | Scale 2: Maximum. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.6.3.9 | ScalarwtWebGraphThermoHygroGraphicsScale3Max | read-only | mandatory | Scale 3: Maximum. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.6.3.10 | ScalarwtWebGraphThermoHygroGraphicsScale4Max | read-only | mandatory | Scale 4: Maximum. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.6.3.11 | ScalarwtWebGraphThermoHygroGraphicsScale1Unit | read-only | mandatory | Scale 1: Unit. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.6.3.12 | ScalarwtWebGraphThermoHygroGraphicsScale2Unit | read-only | mandatory | Scale 2: Unit. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.6.3.13 | ScalarwtWebGraphThermoHygroGraphicsScale3Unit | read-only | mandatory | Scale 3: Unit. |
| 1.3.6.1.4.1.5040.1.2.42.3.1.6.3.14 | ScalarwtWebGraphThermoHygroGraphicsScale4Unit | read-only | mandatory | Scale 4: Unit. |
| 1.3.6.1.4.1.5040.1.2.42.3.2 | NodewtWebGraphThermoHygroPorts | |||
| 1.3.6.1.4.1.5040.1.2.42.3.2.1 | TablewtWebGraphThermoHygroPortTable | not-accessible | mandatory | List of settings depending on the sensor number. |
| 1.3.6.1.4.1.5040.1.2.42.3.2.1.1 | RowwtWebGraphThermoHygroPortEntry | not-accessible | mandatory | Sensor parameters for the individual sensors. |
| 1.3.6.1.4.1.5040.1.2.42.3.2.1.1.1 | ColumnwtWebGraphThermoHygroPortName | read-write | mandatory | Name of the sensor. |
| 1.3.6.1.4.1.5040.1.2.42.3.2.1.1.2 | ColumnwtWebGraphThermoHygroPortText | read-write | mandatory | Description of the sensor. |
| 1.3.6.1.4.1.5040.1.2.42.3.2.1.1.3 | ColumnwtWebGraphThermoHygroPortOffset1 | read-write | mandatory | Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 1. |
| 1.3.6.1.4.1.5040.1.2.42.3.2.1.1.4 | ColumnwtWebGraphThermoHygroPortTemperature1 | read-write | mandatory | Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places. |
| 1.3.6.1.4.1.5040.1.2.42.3.2.1.1.5 | ColumnwtWebGraphThermoHygroPortOffset2 | read-write | mandatory | Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 2. |
| 1.3.6.1.4.1.5040.1.2.42.3.2.1.1.6 | ColumnwtWebGraphThermoHygroPortTemperature2 | read-write | mandatory | Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places. |
| 1.3.6.1.4.1.5040.1.2.42.3.2.1.1.7 | ColumnwtWebGraphThermoHygroPortComment | read-write | mandatory | Offset calibration: informations of date, name of operator, reference devices. |
| 1.3.6.1.4.1.5040.1.2.42.3.2.2 | ScalarwtWebGraphThermoHygroPortAltidude | read-write | mandatory | Altidude oh the Sensor over mean sea level (MSL). |
| 1.3.6.1.4.1.5040.1.2.42.3.3 | NodewtWebGraphThermoHygroManufact | |||
| 1.3.6.1.4.1.5040.1.2.42.3.3.1 | ScalarwtWebGraphThermoHygroMfName | read-write | mandatory | Manufacturer company name |
| 1.3.6.1.4.1.5040.1.2.42.3.3.2 | ScalarwtWebGraphThermoHygroMfAddr | read-write | mandatory | Manufacturer address. |
| 1.3.6.1.4.1.5040.1.2.42.3.3.3 | ScalarwtWebGraphThermoHygroMfHotline | read-write | mandatory | Manufacturer hotline. |
| 1.3.6.1.4.1.5040.1.2.42.3.3.4 | ScalarwtWebGraphThermoHygroMfInternet | read-write | mandatory | Manufacturer Internet address. |
| 1.3.6.1.4.1.5040.1.2.42.3.3.5 | ScalarwtWebGraphThermoHygroMfDeviceTyp | read-write | mandatory | Manufacturer device name (model number). |
| 1.3.6.1.4.1.5040.1.2.42.3.3.6 | ScalarwtWebGraphThermoHygroMfOrderNo | read-write | mandatory | Manufacturer part number. |
| 1.3.6.1.4.1.5040.1.2.42.4 | NodewtWebGraphThermoHygroDiag | |||
| 1.3.6.1.4.1.5040.1.2.42.4.1 | ScalarwtWebGraphThermoHygroDiagErrorCount | read-only | mandatory | Number of entries in the error memory. |
| 1.3.6.1.4.1.5040.1.2.42.4.2 | ScalarwtWebGraphThermoHygroDiagBinaryError | read-only | mandatory | Error causes coded bit-by-bit. |
| 1.3.6.1.4.1.5040.1.2.42.4.3 | ScalarwtWebGraphThermoHygroDiagErrorIndex | read-write | mandatory | The value of this variable is used as an index to read an error massege from wtWebGraphThermoHygroDiagErrorMessage. Errors are numbered from 1 to wtWebGraphThe… |
| 1.3.6.1.4.1.5040.1.2.42.4.4 | ScalarwtWebGraphThermoHygroDiagErrorMessage | read-only | mandatory | Using wtWebGraphThermoHygroDiagErrorIndex as an index, the appropriate message is available. |
| 1.3.6.1.4.1.5040.1.2.42.4.5 | ScalarwtWebGraphThermoHygroDiagErrorClear | write-only | mandatory | Writing 1 into this variable clears all diagnosis messages. |
| 1.3.6.1.4.1.5040.1.2.42.31 | NodewtWebGraphThermoHygroAlert1 | This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled. | ||
| 1.3.6.1.4.1.5040.1.2.42.32 | NodewtWebGraphThermoHygroAlert2 | This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled. | ||
| 1.3.6.1.4.1.5040.1.2.42.33 | NodewtWebGraphThermoHygroAlert3 | This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled. | ||
| 1.3.6.1.4.1.5040.1.2.42.34 | NodewtWebGraphThermoHygroAlert4 | This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled. | ||
| 1.3.6.1.4.1.5040.1.2.42.35 | NodewtWebGraphThermoHygroAlert5 | This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled. | ||
| 1.3.6.1.4.1.5040.1.2.42.36 | NodewtWebGraphThermoHygroAlert6 | This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled. | ||
| 1.3.6.1.4.1.5040.1.2.42.37 | NodewtWebGraphThermoHygroAlert7 | This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled. | ||
| 1.3.6.1.4.1.5040.1.2.42.38 | NodewtWebGraphThermoHygroAlert8 | This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled. | ||
| 1.3.6.1.4.1.5040.1.2.42.91 | NodewtWebGraphThermoHygroAlert9 | This SNMP trap is generated when Alarm 1 was cleared, SNMP trap enable is set and SNMP is enabled. | ||
| 1.3.6.1.4.1.5040.1.2.42.92 | NodewtWebGraphThermoHygroAlert10 | This SNMP trap is generated when Alarm 2 was cleared, SNMP trap enable is set and SNMP is enabled. | ||
| 1.3.6.1.4.1.5040.1.2.42.93 | NodewtWebGraphThermoHygroAlert11 | This SNMP trap is generated when Alarm 3 was cleared, SNMP trap enable is set and SNMP is enabled. | ||
| 1.3.6.1.4.1.5040.1.2.42.94 | NodewtWebGraphThermoHygroAlert12 | This SNMP trap is generated when Alarm 4 was cleared, SNMP trap enable is set and SNMP is enabled. | ||
| 1.3.6.1.4.1.5040.1.2.42.95 | NodewtWebGraphThermoHygroAlert13 | This SNMP trap is generated when Alarm 5 was cleared, SNMP trap enable is set and SNMP is enabled. | ||
| 1.3.6.1.4.1.5040.1.2.42.96 | NodewtWebGraphThermoHygroAlert14 | This SNMP trap is generated when Alarm 6 was cleared, SNMP trap enable is set and SNMP is enabled. | ||
| 1.3.6.1.4.1.5040.1.2.42.97 | NodewtWebGraphThermoHygroAlert15 | This SNMP trap is generated when Alarm 7 was cleared, SNMP trap enable is set and SNMP is enabled. | ||
| 1.3.6.1.4.1.5040.1.2.42.98 | NodewtWebGraphThermoHygroAlert16 | This SNMP trap is generated when Alarm 8 was cleared, SNMP trap enable is set and SNMP is enabled. | ||
| 1.3.6.1.4.1.5040.1.2.42.110 | NodewtWebGraphThermoHygroAlertDiag | This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled. |