XUPS-MIB
220 objects
No module-level DESCRIPTION found.
Imported Objects
| RFC-1212 | OBJECT-TYPE |
| RFC-1215 | TRAP-TYPE |
| RFC1155-SMI | Counter enterprises Gauge TimeTicks |
| RFC1213-MIB | DisplayString ifDescr ifIndex |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.534 | Nodepowerware | |||
| 1.3.6.1.4.1.534.1 | Nodexups | |||
| 1.3.6.1.4.1.534.1.1 | NodexupsIdent | |||
| 1.3.6.1.4.1.534.1.1.1 | ScalarxupsIdentManufacturer | read-only | mandatory | The UPS Manufacturer Name (e.g. Powerware Corporation). |
| 1.3.6.1.4.1.534.1.1.2 | ScalarxupsIdentModel | read-only | mandatory | The UPS Model (e.g. Powerware Plus Model 18). |
| 1.3.6.1.4.1.534.1.1.3 | ScalarxupsIdentSoftwareVersion | read-only | mandatory | The firmware revision level(s) of the UPS microcontroller(s). |
| 1.3.6.1.4.1.534.1.1.4 | ScalarxupsIdentOemCode | read-only | mandatory | A binary code indicating who the UPS was manufactured or labeled for. 0 or 255 indicates Powerware itself. |
| 1.3.6.1.4.1.534.1.2 | NodexupsBattery | |||
| 1.3.6.1.4.1.534.1.2.1 | ScalarxupsBatTimeRemaining | read-only | mandatory | Battery run time in seconds before UPS turns off due to low battery. |
| 1.3.6.1.4.1.534.1.2.2 | ScalarxupsBatVoltage | read-only | mandatory | Battery voltage as reported by the UPS meters. |
| 1.3.6.1.4.1.534.1.2.3 | ScalarxupsBatCurrent | read-only | mandatory | Battery Current as reported by the UPS metering. Current is positive when discharging, negative when recharging the battery. |
| 1.3.6.1.4.1.534.1.2.4 | ScalarxupsBatCapacity | read-only | mandatory | Battery percent charge. |
| 1.3.6.1.4.1.534.1.2.5 | ScalarxupsBatteryAbmStatus | read-only | mandatory | Gives the status of the Advanced Battery Management; batteryFloating(3) status means that the charger is temporarily charging the battery to its float voltage;… |
| 1.3.6.1.4.1.534.1.2.6 | ScalarxupsBatteryLastReplacedDate | read-write | mandatory | The date when the Batteries in this UPS were last replaced. Should be the same as xupsConfigInstallDate initially. Free text format, so the preferred local dat… |
| 1.3.6.1.4.1.534.1.3 | NodexupsInput | |||
| 1.3.6.1.4.1.534.1.3.1 | ScalarxupsInputFrequency | read-only | mandatory | The utility line frequency in tenths of Hz. |
| 1.3.6.1.4.1.534.1.3.2 | ScalarxupsInputLineBads | read-only | mandatory | The number of times the Input was out of tolerance in voltage or frequency. |
| 1.3.6.1.4.1.534.1.3.3 | ScalarxupsInputNumPhases | read-only | mandatory | |
| 1.3.6.1.4.1.534.1.3.4 | TablexupsInputTable | not-accessible | mandatory | The Aggregate Object with number of entries equal to NumPhases and including the xupsInput group. |
| 1.3.6.1.4.1.534.1.3.4.1 | RowxupsInputEntry | not-accessible | mandatory | The input table entry containing the current, voltage, etc. |
| 1.3.6.1.4.1.534.1.3.4.1.1 | ColumnxupsInputPhase | read-only | mandatory | The number of the phase. Serves as index for input table. |
| 1.3.6.1.4.1.534.1.3.4.1.2 | ColumnxupsInputVoltage | read-only | mandatory | The measured input voltage from the UPS meters in volts. |
| 1.3.6.1.4.1.534.1.3.4.1.3 | ColumnxupsInputCurrent | read-only | mandatory | The measured input current from the UPS meters in amps. |
| 1.3.6.1.4.1.534.1.3.4.1.4 | ColumnxupsInputWatts | read-only | mandatory | The measured input real power in watts. |
| 1.3.6.1.4.1.534.1.3.5 | ScalarxupsInputSource | read-only | mandatory | The present external source of input power. The enumeration none(2) indicates that there is no external source of power, for example, the UPS is On Battery (an… |
| 1.3.6.1.4.1.534.1.3.6 | ScalarxupsDualInputStatus | read-only | mandatory | The present status of the sources of input power in a dual source UPS. The enumeration primarySourceGood(2) indicates that the primary source of power is prese… |
| 1.3.6.1.4.1.534.1.3.7 | ScalarxupsSecondaryInputWatch | read-write | mandatory | This object enables(2) or disables(1) the alarms and traps related to the availability and use of the secondary input of a dual-input UPS (i.e., OnAlternatePow… |
| 1.3.6.1.4.1.534.1.4 | NodexupsOutput | |||
| 1.3.6.1.4.1.534.1.4.1 | ScalarxupsOutputLoad | read-only | mandatory | The UPS output load in percent of rated capacity. |
| 1.3.6.1.4.1.534.1.4.2 | ScalarxupsOutputFrequency | read-only | mandatory | The measured UPS output frequency in tenths of Hz. |
| 1.3.6.1.4.1.534.1.4.3 | ScalarxupsOutputNumPhases | read-only | mandatory | The number of metered output phases, serves as the table index. |
| 1.3.6.1.4.1.534.1.4.4 | TablexupsOutputTable | not-accessible | mandatory | The Aggregate Object with number of entries equal to NumPhases and including the xupsOutput group. |
| 1.3.6.1.4.1.534.1.4.4.1 | RowxupsOutputEntry | not-accessible | mandatory | Output Table Entry containing voltage, current, etc. |
| 1.3.6.1.4.1.534.1.4.4.1.1 | ColumnxupsOutputPhase | read-only | mandatory | The number {1..3} of the output phase. |
| 1.3.6.1.4.1.534.1.4.4.1.2 | ColumnxupsOutputVoltage | read-only | mandatory | The measured output voltage from the UPS metering in volts. |
| 1.3.6.1.4.1.534.1.4.4.1.3 | ColumnxupsOutputCurrent | read-only | mandatory | The measured UPS output current in amps. |
| 1.3.6.1.4.1.534.1.4.4.1.4 | ColumnxupsOutputWatts | read-only | mandatory | The measured real output power in watts. |
| 1.3.6.1.4.1.534.1.4.5 | ScalarxupsOutputSource | read-only | mandatory | The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the… |
| 1.3.6.1.4.1.534.1.5 | NodexupsBypass | |||
| 1.3.6.1.4.1.534.1.5.1 | ScalarxupsBypassFrequency | read-only | mandatory | The bypass frequency in tenths of Hz. |
| 1.3.6.1.4.1.534.1.5.2 | ScalarxupsBypassNumPhases | read-only | mandatory | The number of lines in the UPS bypass table. |
| 1.3.6.1.4.1.534.1.5.3 | TablexupsBypassTable | not-accessible | mandatory | |
| 1.3.6.1.4.1.534.1.5.3.1 | RowxupsBypassEntry | not-accessible | mandatory | Entry in the XUPS bypass table. |
| 1.3.6.1.4.1.534.1.5.3.1.1 | ColumnxupsBypassPhase | read-only | mandatory | The Bypass Phase, index for the table. |
| 1.3.6.1.4.1.534.1.5.3.1.2 | ColumnxupsBypassVoltage | read-only | mandatory | The measured UPS bypass voltage in volts. |
| 1.3.6.1.4.1.534.1.6 | NodexupsEnvironment | |||
| 1.3.6.1.4.1.534.1.6.1 | ScalarxupsEnvAmbientTemp | read-only | mandatory | The reading of the ambient temperature in the vicinity of the UPS or SNMP agent. |
| 1.3.6.1.4.1.534.1.6.2 | ScalarxupsEnvAmbientLowerLimit | read-write | mandatory | The Lower Limit of the ambient temperature; if xupsEnvAmbientTemp falls below this value, the xupsAmbientTempBad alarm will occur. |
| 1.3.6.1.4.1.534.1.6.3 | ScalarxupsEnvAmbientUpperLimit | read-write | mandatory | The Upper Limit of the ambient temperature; if xupsEnvAmbientTemp rises above this value, the xupsAmbientTempBad alarm will occur. This value should be greater… |
| 1.3.6.1.4.1.534.1.6.4 | ScalarxupsEnvAmbientHumidity | read-only | mandatory | The reading of the ambient humidity in the vicinity of the UPS or SNMP agent. |
| 1.3.6.1.4.1.534.1.6.5 | ScalarxupsEnvRemoteTemp | read-only | mandatory | The reading of a remote temperature sensor connected to the UPS or SNMP agent. |
| 1.3.6.1.4.1.534.1.6.6 | ScalarxupsEnvRemoteHumidity | read-only | mandatory | The reading of a remote humidity sensor connected to the UPS or SNMP agent. |
| 1.3.6.1.4.1.534.1.6.7 | ScalarxupsEnvNumContacts | read-only | mandatory | The number of Contacts in the xupsContactSenseTable. This object indicates the number of rows in the xupsContactSenseTable. |
| 1.3.6.1.4.1.534.1.6.8 | TablexupsContactSenseTable | not-accessible | mandatory | A list of Contact Sensing table entries. The number of entries is given by the value of xupsEnvNumContacts. |
| 1.3.6.1.4.1.534.1.6.8.1 | RowxupsContactsTableEntry | not-accessible | mandatory | An entry containing information applicable to a particular Contact input. |
| 1.3.6.1.4.1.534.1.6.8.1.1 | ColumnxupsContactIndex | read-only | mandatory | The Contact identifier; identical to the Contact Number. This object is not-accessible to MIB browsers, but had to be changed to read-only to satisfy SMIv2 syn… |
| 1.3.6.1.4.1.534.1.6.8.1.2 | ColumnxupsContactType | read-write | mandatory | The normal state for this contact. The 'other' state is the Active state for generating the xupstdContactActiveNotice trap. If anyChange(3) is selected, then t… |
| 1.3.6.1.4.1.534.1.6.8.1.3 | ColumnxupsContactState | read-only | mandatory | The current state of the Contact input; the value is based on the open/closed input state and the setting for xupsContactType. When entering the openWithNotice… |
| 1.3.6.1.4.1.534.1.6.8.1.4 | ColumnxupsContactDescr | read-write | mandatory | A label identifying the Contact. This object should be set by the administrator. |
| 1.3.6.1.4.1.534.1.6.9 | ScalarxupsEnvRemoteTempLowerLimit | read-write | mandatory | The Lower Limit of the remote temperature; if xupsEnvRemoteTemp falls below this value, the xupsRemoteTempBad alarm will occur. |
| 1.3.6.1.4.1.534.1.6.10 | ScalarxupsEnvRemoteTempUpperLimit | read-write | mandatory | The Upper Limit of the remote temperature; if xupsEnvRemoteTemp rises above this value, the xupsRemoteTempBad alarm will occur. This value should be greater th… |
| 1.3.6.1.4.1.534.1.6.11 | ScalarxupsEnvRemoteHumidityLowerLimit | read-write | mandatory | The Lower Limit of the remote humidity reading; if xupsEnvRemoteHumidity falls below this value, the xupsRemoteHumidityBad alarm will occur. |
| 1.3.6.1.4.1.534.1.6.12 | ScalarxupsEnvRemoteHumidityUpperLimit | read-write | mandatory | The Upper Limit of the remote humidity reading; if xupsEnvRemoteHumidity rises above this value, the xupsRemoteHumidityBad alarm will occur. This value should … |
| 1.3.6.1.4.1.534.1.7 | NodexupsAlarm | |||
| 1.3.6.1.4.1.534.1.7.1 | ScalarxupsAlarms | read-only | mandatory | The current number of alarm conditions. |
| 1.3.6.1.4.1.534.1.7.2 | TablexupsAlarmTable | not-accessible | mandatory | |
| 1.3.6.1.4.1.534.1.7.2.1 | RowxupsAlarmEntry | not-accessible | mandatory | |
| 1.3.6.1.4.1.534.1.7.2.1.1 | ColumnxupsAlarmID | read-only | mandatory | A unique identifier for an alarm condition. |
| 1.3.6.1.4.1.534.1.7.2.1.2 | ColumnxupsAlarmDescr | read-only | mandatory | A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm con… |
| 1.3.6.1.4.1.534.1.7.2.1.3 | ColumnxupsAlarmTime | read-only | mandatory | The value of the MIB-II variable sysUpTime when the alarm condition occurred. |
| 1.3.6.1.4.1.534.1.7.3 | NodexupsOnBattery | |||
| 1.3.6.1.4.1.534.1.7.4 | NodexupsLowBattery | |||
| 1.3.6.1.4.1.534.1.7.5 | NodexupsUtilityPowerRestored | |||
| 1.3.6.1.4.1.534.1.7.6 | NodexupsReturnFromLowBattery | |||
| 1.3.6.1.4.1.534.1.7.7 | NodexupsOutputOverload | |||
| 1.3.6.1.4.1.534.1.7.8 | NodexupsInternalFailure | |||
| 1.3.6.1.4.1.534.1.7.9 | NodexupsBatteryDischarged | |||
| 1.3.6.1.4.1.534.1.7.10 | NodexupsInverterFailure | |||
| 1.3.6.1.4.1.534.1.7.11 | NodexupsOnBypass | |||
| 1.3.6.1.4.1.534.1.7.12 | NodexupsBypassNotAvailable | |||
| 1.3.6.1.4.1.534.1.7.13 | NodexupsOutputOff | |||
| 1.3.6.1.4.1.534.1.7.14 | NodexupsInputFailure | |||
| 1.3.6.1.4.1.534.1.7.15 | NodexupsBuildingAlarm | |||
| 1.3.6.1.4.1.534.1.7.16 | NodexupsShutdownImminent | |||
| 1.3.6.1.4.1.534.1.7.17 | NodexupsOnInverter | |||
| 1.3.6.1.4.1.534.1.7.18 | ScalarxupsAlarmNumEvents | read-only | mandatory | The number of entries in the UPS event history queue. |
| 1.3.6.1.4.1.534.1.7.19 | TablexupsAlarmEventTable | not-accessible | mandatory | A table of the UPS internal event history queue. |
| 1.3.6.1.4.1.534.1.7.19.1 | RowxupsAlarmEventEntry | not-accessible | mandatory | One of the entries in the UPS event history queue. |
| 1.3.6.1.4.1.534.1.7.19.1.1 | ColumnxupsAlarmEventID | not-accessible | mandatory | A unique number that reflects the order in which the event occurred. The oldest event in the queue will be number 1. Subsequent events will be numbered 2, 3, 4… |
| 1.3.6.1.4.1.534.1.7.19.1.2 | ColumnxupsAlarmEventDateAndTime | read-only | deprecated | The time and date that an event occurred as recorded in the UPS internal event queue. This string will reflect the time and date as set in the UPS itself and w… |
| 1.3.6.1.4.1.534.1.7.19.1.3 | ColumnxupsAlarmEventKind | read-only | deprecated | Enumerated value that tells whether the event is an occurrence of an alarm condition or a clearing of an alarm condition. |
| 1.3.6.1.4.1.534.1.7.19.1.4 | ColumnxupsAlarmEventDescr | read-only | deprecated | A description of the event stored in the UPS event queue. This description will be a sixteen bit integer value representing one of the defined alarms in the Po… |
| 1.3.6.1.4.1.534.1.7.19.1.5 | ColumnxupsAlarmEventMsg | read-only | mandatory | A text string describing each entry in the Event Log. The format of this text message is free (not fixed) for the operator to read; good contents would be a ti… |
| 1.3.6.1.4.1.534.1.7.20 | NodexupsBreakerOpen | |||
| 1.3.6.1.4.1.534.1.7.21 | NodexupsAlarmEntryAdded | |||
| 1.3.6.1.4.1.534.1.7.22 | NodexupsAlarmEntryRemoved | |||
| 1.3.6.1.4.1.534.1.7.23 | NodexupsAlarmBatteryBad | |||
| 1.3.6.1.4.1.534.1.7.24 | NodexupsOutputOffAsRequested | |||
| 1.3.6.1.4.1.534.1.7.25 | NodexupsDiagnosticTestFailed | |||
| 1.3.6.1.4.1.534.1.7.26 | NodexupsCommunicationsLost | |||
| 1.3.6.1.4.1.534.1.7.27 | NodexupsUpsShutdownPending | |||
| 1.3.6.1.4.1.534.1.7.28 | NodexupsAlarmTestInProgress | |||
| 1.3.6.1.4.1.534.1.7.29 | NodexupsAmbientTempBad | |||
| 1.3.6.1.4.1.534.1.7.30 | NodexupsLossOfRedundancy | |||
| 1.3.6.1.4.1.534.1.7.31 | NodexupsAlarmTempBad | |||
| 1.3.6.1.4.1.534.1.7.32 | NodexupsAlarmChargerFailed | |||
| 1.3.6.1.4.1.534.1.7.33 | NodexupsAlarmFanFailure | |||
| 1.3.6.1.4.1.534.1.7.34 | NodexupsAlarmFuseFailure | |||
| 1.3.6.1.4.1.534.1.7.35 | NodexupsPowerSwitchBad | |||
| 1.3.6.1.4.1.534.1.7.36 | NodexupsModuleFailure | |||
| 1.3.6.1.4.1.534.1.7.37 | NodexupsOnAlternatePowerSource | |||
| 1.3.6.1.4.1.534.1.7.38 | NodexupsAltPowerNotAvailable | |||
| 1.3.6.1.4.1.534.1.7.39 | NodexupsNoticeCondition | |||
| 1.3.6.1.4.1.534.1.7.40 | NodexupsRemoteTempBad | |||
| 1.3.6.1.4.1.534.1.7.41 | NodexupsRemoteHumidityBad | |||
| 1.3.6.1.4.1.534.1.7.42 | NodexupsAlarmOutputBad | |||
| 1.3.6.1.4.1.534.1.7.43 | NodexupsAlarmAwaitingPower | |||
| 1.3.6.1.4.1.534.1.7.44 | NodexupsOnMaintenanceBypass | |||
| 1.3.6.1.4.1.534.1.8 | NodexupsTest | |||
| 1.3.6.1.4.1.534.1.8.1 | ScalarxupsTestStart | read-write | mandatory | Setting this object initiates the requested Test. If a UPS does not support the requested test, the set operation may succeed but the result will end up as not… |
| 1.3.6.1.4.1.534.1.8.2 | ScalarxupsTestBatteryStatus | read-only | mandatory | Reading this enumerated value gives an indication of the (last) UPS Battery test status. |
| 1.3.6.1.4.1.534.1.8.3 | ScalarxupsLastGeneralTest | read-only | mandatory | Indicates the last UPS test requested via xupsTestStart or by other non-SNMP means, other than for the testBattery (1) case. The results of the test indicated … |
| 1.3.6.1.4.1.534.1.8.4 | ScalarxupsLastGeneralTestResult | read-only | mandatory | Reading this enumerated value gives the result of the test indicated in xupsLastGeneralTest. |
| 1.3.6.1.4.1.534.1.9 | NodexupsControl | |||
| 1.3.6.1.4.1.534.1.9.1 | ScalarxupsControlOutputOffDelay | read-write | mandatory | Setting this value to other than zero will cause the UPS output to turn off after the number of seconds. Setting it to 0 will cause an attempt to abort a pendi… |
| 1.3.6.1.4.1.534.1.9.2 | ScalarxupsControlOutputOnDelay | read-write | mandatory | Setting this value to other than zero will cause the UPS output to turn on after the number of seconds. Setting it to 0 will cause an attempt to abort a pendin… |
| 1.3.6.1.4.1.534.1.9.3 | ScalarxupsControlOutputOffTrapDelay | read-write | mandatory | When xupsControlOutputOffDelay reaches this value, a trap will be sent. |
| 1.3.6.1.4.1.534.1.9.4 | ScalarxupsControlOutputOnTrapDelay | read-write | deprecated | When xupsControlOutputOnDelay reaches this value, a xupsOutputOff trap will be sent. |
| 1.3.6.1.4.1.534.1.9.5 | ScalarxupsControlToBypassDelay | read-write | mandatory | Setting this value to other than zero will cause the UPS output to go to Bypass after the number of seconds. If the Bypass is unavailable, this may cause the U… |
| 1.3.6.1.4.1.534.1.9.6 | ScalarxupsLoadShedSecsWithRestart | read-write | mandatory | Setting this value will cause the UPS output to turn off after the set number of seconds, then restart (after a UPS-defined 'down time') when the utility is ag… |
| 1.3.6.1.4.1.534.1.10 | NodexupsConfig | |||
| 1.3.6.1.4.1.534.1.10.1 | ScalarxupsConfigOutputVoltage | read-only | mandatory | The nominal UPS Output voltage per phase in volts. |
| 1.3.6.1.4.1.534.1.10.2 | ScalarxupsConfigInputVoltage | read-only | mandatory | The nominal UPS Input voltage per phase in volts. |
| 1.3.6.1.4.1.534.1.10.3 | ScalarxupsConfigOutputWatts | read-only | mandatory | The nominal UPS available real power output in watts. |
| 1.3.6.1.4.1.534.1.10.4 | ScalarxupsConfigOutputFreq | read-only | mandatory | The nominal output frequency in tenths of Hz. |
| 1.3.6.1.4.1.534.1.10.5 | ScalarxupsConfigDateAndTime | read-write | mandatory | Date and time information for the UPS. Setting this variable will initiate a set UPS date and time to this value. Reading this variable will return the UPS tim… |
| 1.3.6.1.4.1.534.1.10.6 | ScalarxupsConfigLowOutputVoltageLimit | read-only | mandatory | The Lower limit for acceptable Output Voltage, per the UPS specifications. |
| 1.3.6.1.4.1.534.1.10.7 | ScalarxupsConfigHighOutputVoltageLimit | read-only | mandatory | The Upper limit for acceptable Output Voltage, per the UPS specifications. |
| 1.3.6.1.4.1.534.1.10.8 | ScalarxupsConfigInstallDate | read-write | mandatory | The date when this UPS was installed. Free text format, so the preferred local date format may be used (MM/DD/YYYY, DD-Mon-YYYY, etc). |
| 1.3.6.1.4.1.534.1.11 | NodexupsTrapControl | |||
| 1.3.6.1.4.1.534.1.11.1 | ScalarxupsMaxTrapLevel | read-write | mandatory | The level of severity of traps which will be sent to the requesting host; individual trap receivers will have individual values for this variable. Values are: … |
| 1.3.6.1.4.1.534.1.11.2 | ScalarxupsSendTrapType | read-write | mandatory | The type of traps which will be sent to the requesting host; individual trap receivers will have individual values for this variable. The additional variables … |
| 1.3.6.1.4.1.534.1.11.3 | ScalarxupsTrapMessage | read-only | mandatory | A descriptive text message which may be sent with traps to further explain the reason for the trap. This object is not-accessible to MIB browsers, but had to b… |
| 1.3.6.1.4.1.534.1.11.4 | NodexupsTrapSource | |||
| 1.3.6.1.4.1.534.1.11.4.1 | NodexupsTrapDefined | |||
| 1.3.6.1.4.1.534.1.11.4.1.1 | NodexupstdControlOff | The UPS output power will turn off in a number of seconds equal to upsControlOutputOffTrapDelay. | ||
| 1.3.6.1.4.1.534.1.11.4.1.2 | NodexupstdControlOn | The UPS output power will turn on in a number of seconds equal to upsControlOutputOnTrapDelay. | ||
| 1.3.6.1.4.1.534.1.11.4.1.3 | NodexupstdOnBattery | The UPS has no AC input power and is running on battery. | ||
| 1.3.6.1.4.1.534.1.11.4.1.4 | NodexupstdLowBattery | The UPS batteries are low. Tied to low battery alarm condition. | ||
| 1.3.6.1.4.1.534.1.11.4.1.5 | NodexupstdUtilityPowerRestored | Input power has been restored after running on battery. | ||
| 1.3.6.1.4.1.534.1.11.4.1.6 | NodexupstdReturnFromLowBattery | The battery has recovered from a low battery condition. | ||
| 1.3.6.1.4.1.534.1.11.4.1.7 | NodexupstdOutputOverload | The ups has sensed an overload of greater than 106 percent. Tied to the 106% overload alarm. | ||
| 1.3.6.1.4.1.534.1.11.4.1.8 | NodexupstdInternalFailure | Some component of the ups - rectifier, inverter, control panel has failed. Tied to alarms indi- cating failure. | ||
| 1.3.6.1.4.1.534.1.11.4.1.9 | NodexupstdBatteryDischarged | The Battery Totally Discharged Alarm has occurred. | ||
| 1.3.6.1.4.1.534.1.11.4.1.10 | NodexupstdInverterFailure | The ups inverter is unavailable due to an internal failure. | ||
| 1.3.6.1.4.1.534.1.11.4.1.11 | NodexupstdOnBypass | The ups has gone on bypass for some reason. | ||
| 1.3.6.1.4.1.534.1.11.4.1.12 | NodexupstdBypassNotAvailable | The ups bypass is unavailable | ||
| 1.3.6.1.4.1.534.1.11.4.1.13 | NodexupstdOutputOff | The ups output is switched off. | ||
| 1.3.6.1.4.1.534.1.11.4.1.14 | NodexupstdInputFailure | The ups input power is incorrect in voltage, frequency, or phase rotation. | ||
| 1.3.6.1.4.1.534.1.11.4.1.15 | NodexupstdBuildingAlarm | One of the defined building alarms has occurred. | ||
| 1.3.6.1.4.1.534.1.11.4.1.16 | NodexupstdShutdownImminent | The ups shutdown imminent alarm has occurred. | ||
| 1.3.6.1.4.1.534.1.11.4.1.17 | NodexupstdOnInverter | The ups is returned to utility power running the inverter after either a transfer to bypass or a run on battery. | ||
| 1.3.6.1.4.1.534.1.11.4.1.20 | NodexupstdBreakerOpen | One of the UPS breakers or contactors has been opened. | ||
| 1.3.6.1.4.1.534.1.11.4.1.21 | NodexupstdAlarmEntryAdded | An alarm not defined in the xups Well Known Alarms (eg, an alarm defined in RFC1628) has been added to the Alarm Table. | ||
| 1.3.6.1.4.1.534.1.11.4.1.22 | NodexupstdAlarmEntryRemoved | An alarm not defined in the xups Well Known Alarms has been removed from the Alarm Table. | ||
| 1.3.6.1.4.1.534.1.11.4.1.23 | NodexupstdAlarmBatteryBad | One or more batteries have been determined to require replacement. | ||
| 1.3.6.1.4.1.534.1.11.4.1.24 | NodexupstdOutputOffAsRequested | The UPS has shutdown as requested, i.e., the output is off. | ||
| 1.3.6.1.4.1.534.1.11.4.1.25 | NodexupstdDiagnosticTestFailed | The result of the last diagnostic test indicates a failure. | ||
| 1.3.6.1.4.1.534.1.11.4.1.26 | NodexupstdCommunicationsLost | A problem has been encountered in the communications between the agent and the UPS. | ||
| 1.3.6.1.4.1.534.1.11.4.1.27 | NodexupstdUpsShutdownPending | An xupsControlOutputOffDelay countdown is underway. | ||
| 1.3.6.1.4.1.534.1.11.4.1.28 | NodexupstdAlarmTestInProgress | A test is in progress, as initiated and indicated by the xupsTest Group. When the test is complete, one of the following traps will be sent: - xupstdDiagnostic… | ||
| 1.3.6.1.4.1.534.1.11.4.1.29 | NodexupstdAmbientTempBad | The ambient temperature, xupsEnvAmbientTemp, has fallen below the set lower limit, xupsEnvAmbientLowerLimit, or has risen above the set upper limit, xupsEnvAmb… | ||
| 1.3.6.1.4.1.534.1.11.4.1.30 | NodexupstdContactActiveNotice | The Contact indicated by xupsContactIndex is in its Active state. The following are the situations that generate this trap: For xupsContactType: and xupsContac… | ||
| 1.3.6.1.4.1.534.1.11.4.1.31 | NodexupstdContactInactiveNotice | The Contact indicated by xupsContactIndex has changed to its Inactive state. | ||
| 1.3.6.1.4.1.534.1.11.4.1.32 | NodexupstdLossOfRedundancy | A parallel UPS system is no longer operating in N+1 redundant mode; this may be due to module failure or removal, or due to overloading. | ||
| 1.3.6.1.4.1.534.1.11.4.1.33 | NodexupstdAlarmTempBad | An internal temperature is out of tolerance. | ||
| 1.3.6.1.4.1.534.1.11.4.1.34 | NodexupstdAlarmChargerFailed | An uncorrected problem has been detected within the UPS charger subsystem. | ||
| 1.3.6.1.4.1.534.1.11.4.1.35 | NodexupstdAlarmFanFailure | The failure of one or more fans in the UPS has been detected. | ||
| 1.3.6.1.4.1.534.1.11.4.1.36 | NodexupstdAlarmFuseFailure | The failure of one or more fuses has been detected. | ||
| 1.3.6.1.4.1.534.1.11.4.1.37 | NodexupstdPowerSwitchBad | A Relay, Contactor, or Breaker has failed. | ||
| 1.3.6.1.4.1.534.1.11.4.1.38 | NodexupstdModuleFailure | One module in a parallel or composite system has failed. | ||
| 1.3.6.1.4.1.534.1.11.4.1.39 | NodexupstdOnAlternatePowerSource | The system is being powered by its Alternate Power Source, such as a Secondary utility feed (on a dual AC input UPS), generator, flywheel, or fuel cell. | ||
| 1.3.6.1.4.1.534.1.11.4.1.40 | NodexupstdAltPowerNotAvailable | On systems with a separate alternate power source (eg, dual AC inputs), that alternate power source is currently not available. This could be a problem if the … | ||
| 1.3.6.1.4.1.534.1.11.4.1.41 | NodexupstdNoticeCondition | Some Notice condition exists which is not covered by the other traps. This is like an xupstdInternalFailure, but at a lower severity level. | ||
| 1.3.6.1.4.1.534.1.11.4.1.42 | NodexupstdRemoteTempBad | The remote temperature, xupsEnvRemoteTemp, has fallen below the set lower limit, xupsEnvRemoteTempLowerLimit, or has risen above the set upper limit, xupsEnvRe… | ||
| 1.3.6.1.4.1.534.1.11.4.1.43 | NodexupstdRemoteHumidityBad | The remote temperature, xupsEnvRemoteHumidity, has fallen below the set lower limit, xupsEnvRemoteHumidityLowerLimit, or has risen above the set upper limit, x… | ||
| 1.3.6.1.4.1.534.1.11.4.1.44 | NodexupstdHeartbeat | A periodic status trap message. It is sent at an interval set by object xupsHeartbeatMinsInterval. The included variables provide a brief statement of the UPS … | ||
| 1.3.6.1.4.1.534.1.11.4.1.45 | NodexupstdDiagnosticTestPassed | A diagnostic test just completed, and its result is Passed. The included variables provide additional information on the test. | ||
| 1.3.6.1.4.1.534.1.11.4.1.46 | NodexupstdOutputBad | The output condition (other than OutputOverload) is out of tolerance. | ||
| 1.3.6.1.4.1.534.1.11.4.1.47 | NodexupstdAwaitingPower | The UPS output is off and the UPS is awaiting the return of input power. | ||
| 1.3.6.1.4.1.534.1.11.4.1.48 | NodexupstdOnMaintenanceBypass | The UPS has been placed on Maintenance / Manual Bypass by an operator. | ||
| 1.3.6.1.4.1.534.1.11.4.1.49 | NodexupstdCommEstablished | This trap is sent when the SNMP agent first establishes a communication link with the UPS. The included variables provide identification and UPS status informa… | ||
| 1.3.6.1.4.1.534.1.11.4.1.50 | NodexupstdAgentDown | This trap is sent when the SNMP agent is exiting or closing down gracefully. This may be triggered by a signal from the OS to stop this process. In many implem… | ||
| 1.3.6.1.4.1.534.1.11.5 | ScalarxupsHeartbeatMinsInterval | read-write | mandatory | How often to send the xupstdHeartbeat trap, in units of minutes. A setting of 0 disables the Heartbeat function. |
| 1.3.6.1.4.1.534.1.12 | NodexupsRecep | |||
| 1.3.6.1.4.1.534.1.12.1 | ScalarxupsNumReceptacles | read-only | mandatory | The number of independently controllable Receptacles, as described in the xupsRecepTable. |
| 1.3.6.1.4.1.534.1.12.2 | TablexupsRecepTable | not-accessible | mandatory | The Aggregate Object with number of entries equal to NumReceptacles and including the xupsRecep group. |
| 1.3.6.1.4.1.534.1.12.2.1 | RowxupsRecepEntry | not-accessible | mandatory | The Recep table entry, etc. |
| 1.3.6.1.4.1.534.1.12.2.1.1 | ColumnxupsRecepIndex | read-only | mandatory | The number of the Receptacle. Serves as index for Receptacle table. |
| 1.3.6.1.4.1.534.1.12.2.1.2 | ColumnxupsRecepStatus | read-only | mandatory | The Recep Status 1=On/Close, 2=Off/Open, 3=On w/Pending Off, 4=Off w/Pending ON, 5=Unknown, 6=Reserved for future, 7=Failed in Closed position, 8=Failed in Ope… |
| 1.3.6.1.4.1.534.1.12.2.1.3 | ColumnxupsRecepOffDelaySecs | read-write | mandatory | The Delay until the Receptacle is turned Off. Setting this value to other than -1 will cause the UPS output to turn off after the number of seconds (0 is immed… |
| 1.3.6.1.4.1.534.1.12.2.1.4 | ColumnxupsRecepOnDelaySecs | read-write | mandatory | The Delay until the Receptacle is turned On. Setting this value to other than -1 will cause the UPS output to turn on after the number of seconds (0 is immedia… |
| 1.3.6.1.4.1.534.1.12.2.1.5 | ColumnxupsRecepAutoOffDelay | read-write | mandatory | The delay after going On Battery until the Receptacle is automatically turned Off. A value of -1 means that this Output should never be turned Off automaticall… |
| 1.3.6.1.4.1.534.1.12.2.1.6 | ColumnxupsRecepAutoOnDelay | read-write | mandatory | Seconds delay after the Outlet is signaled to turn On before the Output is Automatically turned ON. A value of -1 means that this Output should never be turned… |
| 1.3.6.1.4.1.534.1.12.2.1.7 | ColumnxupsRecepShedSecsWithRestart | read-write | mandatory | Setting this value will cause the UPS output to turn off after the set number of seconds, then restart (after a UPS-defined 'down time') when the utility is ag… |
| 1.3.6.1.4.1.534.1.13 | NodexupsTopology | |||
| 1.3.6.1.4.1.534.1.13.1 | ScalarxupsTopologyType | read-only | mandatory | Value which denotes the type of UPS by its power topology. Values are the same as those described in the XCP Topology block's Overall Topology field. |
| 1.3.6.1.4.1.534.1.13.2 | ScalarxupsTopoMachineCode | read-only | mandatory | ID Value which denotes the Powerware model of the UPS for software. Values are the same as those described in the XCP Configuration block's Machine Code field. |
| 1.3.6.1.4.1.534.1.13.3 | ScalarxupsTopoUnitNumber | read-only | mandatory | Identifies which unit and what type of data is being reported. A value of 0 means that this MIB information comes from the top-level system view (eg, manifold … |
| 1.3.6.1.4.1.534.1.13.4 | ScalarxupsTopoPowerStrategy | read-write | mandatory | Value which denotes which Power Strategy is currently set for the UPS. The values are: highAlert(1) - The UPS shall optimize its operating state to maximize it… |
| 1.3.6.1.4.1.534.2 | NodexupsObjectId | |||
| 1.3.6.1.4.1.534.2.1 | NodepowerwareEthernetSnmpAdapter | |||
| 1.3.6.1.4.1.534.2.2 | NodepowerwareNetworkSnmpAdapterEther | |||
| 1.3.6.1.4.1.534.2.3 | NodepowerwareNetworkSnmpAdapterToken | |||
| 1.3.6.1.4.1.534.2.4 | NodeonlinetDaemon | |||
| 1.3.6.1.4.1.534.2.5 | NodeconnectUPSAdapterEthernet | |||
| 1.3.6.1.4.1.534.2.6 | NodepowerwareNetworkDigitalIOEther | |||
| 1.3.6.1.4.1.534.2.7 | NodeconnectUPSAdapterTokenRing | |||
| 1.3.6.1.4.1.534.2.8 | NodesimpleSnmpAdapter | |||
| 1.3.6.1.4.1.534.2.9 | NodepowerwareEliSnmpAdapter |