MIB Viewer

ZHNSYSMON

37 objects
This MIB contains objects that are used by the System Monitoring function. ============================================================== == == == Copyright (C) 2007-2010 Zhone Technologies, Inc. == == == ==============================================================
Imported Objects
SNMPv2-SMIMODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32
SNMPv2-TCDateAndTime DisplayString RowStatus
ZhonezhoneWtn
OIDNameAccessStatusDescription
1.3.6.1.4.1.5504.2.5.1IdentityzhnSysMonofThis MIB contains objects that are used by the System Monitoring function. ============================================================== == == == Copyright (C…
1.3.6.1.4.1.5504.2.5.1.0NodezhnSysMonNotifications
1.3.6.1.4.1.5504.2.5.1.0.1NotificationzhnSysMonAlarmSetEventcurrentA zhnSysMonAlarmSetEvent notification is sent when an alarm condition is detected by a system component. The System Monitor is informed of the alarm and genera…
1.3.6.1.4.1.5504.2.5.1.0.2NotificationzhnSysMonAlarmClearEventcurrentA zhnSysMonAlarmClearEvent notification is sent when an alarm condition is cleared by a system component. The System Monitor is informed of the alarm state and…
1.3.6.1.4.1.5504.2.5.1.0.3NotificationzhnSysMonTestStartEventcurrentA zhnSysMonTestStartEvent notification is sent by any system component that begins a test. The objects in the notification correspond to the values in a row in…
1.3.6.1.4.1.5504.2.5.1.0.4NotificationzhnSysMonTestStopEventcurrentA zhnSysMonTestStopEvent notification is sent by any system component that ends a test. The objects in the notification correspond to the values in a row insta…
1.3.6.1.4.1.5504.2.5.1.0.5NotificationzhnSysMonTempSensorCfgUpdateEventcurrentA zhnSysMonTempCfgUpdateEvent notification is sent by the System Monitor whenever it reconfigures a temperature sensor. The objects in the notification corresp…
1.3.6.1.4.1.5504.2.5.1.0.6NotificationzhnSysMonLinePowerCfgUpdateEventcurrentA zhnSysMonLinePowerCfgUpdateEvent notification is sent by the System Monitor whenever it reconfigures a power source line. The objects in the notification cor…
1.3.6.1.4.1.5504.2.5.1.0.7NotificationzhnSysMonReadyEventcurrentA zhnSysMonReadyEvent notification is sent by the System Monitor whenever it has completed initialization and is ready to accept requests.
1.3.6.1.4.1.5504.2.5.1.0.8NotificationzhnSysMonConfigChangeEventcurrentA zhnSysMonConfigChangeEvent notification is generated whenever the persistent database is saved.
1.3.6.1.4.1.5504.2.5.1.1NodezhnSysMonObjects
1.3.6.1.4.1.5504.2.5.1.1.1TablezhnSysMonAlarmTablenot-accessiblecurrentThis table contains the current system alarms.
1.3.6.1.4.1.5504.2.5.1.1.1.1RowzhnSysMonAlarmEntrynot-accessiblecurrentAn entry in the zhnSysMonAlarmTable.
1.3.6.1.4.1.5504.2.5.1.1.1.1.1ColumnzhnSysMonAlarmTyperead-createcurrentThe type of alarm currently posted.
1.3.6.1.4.1.5504.2.5.1.1.1.1.2ColumnzhnSysMonAlarmSeverityread-createcurrentThe severity of the alarm.
1.3.6.1.4.1.5504.2.5.1.1.1.1.3ColumnzhnSysMonAlarmInterfaceNameread-createcurrentThis object specifies the interface name (e.g., wlan0), or instance (e.g., sensor 1, primary power source 3) associated with the alarm.
1.3.6.1.4.1.5504.2.5.1.1.1.1.4ColumnzhnSysMonAlarmDescriptionread-createcurrentThis object is a textual description of an alarm type.
1.3.6.1.4.1.5504.2.5.1.1.1.1.5ColumnzhnSysMonAlarmRowStatusread-createcurrentThe SNMP RowStatus of the current row.
1.3.6.1.4.1.5504.2.5.1.1.2TablezhnSysMonTestTablenot-accessiblecurrentThis table contains the current system tests.
1.3.6.1.4.1.5504.2.5.1.1.2.1RowzhnSysMonTestEntrynot-accessiblecurrentAn entry in the zhnSysMonTestTable.
1.3.6.1.4.1.5504.2.5.1.1.2.1.1ColumnzhnSysMonTestTyperead-createcurrentThe type of test currently running.
1.3.6.1.4.1.5504.2.5.1.1.2.1.2ColumnzhnSysMonTestInterfaceNameread-createcurrentThis object specifies the interface name (e.g., wlan0) associated with the test.
1.3.6.1.4.1.5504.2.5.1.1.2.1.3ColumnzhnSysMonTestRowStatusread-createcurrentThe SNMP RowStatus of the current row.
1.3.6.1.4.1.5504.2.5.1.1.3TablezhnSysMonTempSensorTablenot-accessiblecurrentThis table contains the system temperature sensors.
1.3.6.1.4.1.5504.2.5.1.1.3.1RowzhnSysMonTempSensorEntrynot-accessiblecurrentAn entry in the zhnSysMonTempSensorTable.
1.3.6.1.4.1.5504.2.5.1.1.3.1.1ColumnzhnSysMonTempSensorIdread-createcurrentThis object specifies the reference index for each detected temperature sensor.
1.3.6.1.4.1.5504.2.5.1.1.3.1.2ColumnzhnSysMonTempSensorRowStatusread-createcurrentThe SNMP RowStatus of the current row.
1.3.6.1.4.1.5504.2.5.1.1.3.1.3ColumnzhnSysMonTempSensorCurrread-onlycurrentThe current temperature reported by the sensor in degrees Celcius.
1.3.6.1.4.1.5504.2.5.1.1.3.1.4ColumnzhnSysMonTempSensorOSread-writecurrentThe configured Overtemperature Shutdown (OS) for the sensor in degrees Celcius. This is the temperature alarm threshold
1.3.6.1.4.1.5504.2.5.1.1.3.1.5ColumnzhnSysMonTempSensorHystread-writecurrentThe configured temperature hysteresis for the sensor in degrees Celcius. This is the temperature at which the alarm condition goes away.
1.3.6.1.4.1.5504.2.5.1.1.3.1.6ColumnzhnSysMonTempSensorNameread-writecurrentA textual string describing the sensor.
1.3.6.1.4.1.5504.2.5.1.1.4TablezhnSysMonLinePowerTablenot-accessiblecurrentThis table contains the line power configuration.
1.3.6.1.4.1.5504.2.5.1.1.4.1RowzhnSysMonLinePowerEntrynot-accessiblecurrentAn entry in the zhnSysMonLinePowerTable.
1.3.6.1.4.1.5504.2.5.1.1.4.1.1ColumnzhnSysMonLinePowerLineNumberread-createcurrentThis object specifies the line number for each primary power source.
1.3.6.1.4.1.5504.2.5.1.1.4.1.2ColumnzhnSysMonLinePowerStatusread-createcurrentThe current power configuration status of the line identified by zhnSysMonLinePowerLineNumber. A status of enabled(1) indicates that the line is being monitore…
1.3.6.1.4.1.5504.2.5.1.1.4.1.3ColumnzhnSysMonLinePowerRowStatusread-createcurrentThe SNMP RowStatus of the current row.
1.3.6.1.4.1.5504.2.5.1.2NodezhnSysMonConformance