MIB Viewer

ZHONE-SECHTOR100-MIB

31 objects
MIB module for elements specific to Sechtor 100 products.
Imported Objects
SNMPv2-SMIInteger32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-IDENTITY OBJECT-TYPE
SNMPv2-TCMacAddress TruthValue
Zhonesechtor100 zhoneModules zhoneShelfIndex zhoneSlotIndex
Zhone-TCZhoneRowStatus
OIDNameAccessStatusDescription
1.3.6.1.4.1.5504.2.4.1.1Identitysechtor100EnvironmentdeprecatedAll the scalar objects under sechor100Environment are deprecated and replaced by their respective objects indexed by zhoneShelfIndex and zhoneSlotIndex.
1.3.6.1.4.1.5504.2.4.1.1.1Scalars100FanOperationalStatusread-onlydeprecatedThis variable describes the working status of the four fans for the Sechtor 100. If any one of the four fans is not running correctly, this variable shows 'fan…
1.3.6.1.4.1.5504.2.4.1.1.2Scalars100ThermoAUpperThresholdread-writedeprecatedThis variable specifies the upper threshold for thermometer A in degrees Celsius. When s100ThermoATemperature is above this value, s100ThermoAOperationalStatus…
1.3.6.1.4.1.5504.2.4.1.1.3Scalars100ThermoBUpperThresholdread-writedeprecatedThis variable specifies the upper threshold for thermometer B in degrees Celsius. When s100ThermoBTemperature is above this value, s100ThermoBOperationalStatus…
1.3.6.1.4.1.5504.2.4.1.1.4Scalars10ThermoALowerThresholdread-writedeprecatedThis variable specifies the lower threshold for thermometer A in degrees Celsius. When s100ThermoATemperature is below this value, s100ThermoAOperationalStatus…
1.3.6.1.4.1.5504.2.4.1.1.5Scalars100ThermoBLowerThresholdread-writedeprecatedThis variable specifies the lower threshold for thermometer B in degrees Celsius. When s100ThermoATemperature is below this value, s100ThermoBOperationalStatus…
1.3.6.1.4.1.5504.2.4.1.1.6Scalars100ThermoATemperatureread-onlydeprecatedThe temperature in degrees Celsius read by the IC thermometer sensor A on the PCB board. It is effectively the internal ambient temperature inside the enclosur…
1.3.6.1.4.1.5504.2.4.1.1.7Scalars100ThermoBTemperatureread-onlydeprecatedThe temperature in degrees Celsius read by the IC thermometer sensor B on the PCB board. It is effectively the internal ambient temperature inside the enclosur…
1.3.6.1.4.1.5504.2.4.1.1.8Scalars100ThermoAOperationalStatusread-onlydeprecatedThe operational status indicator for thermometer A. Valid values are: * withinOperationalRange - s100ThermoATemperature is within its lower and upper threshold…
1.3.6.1.4.1.5504.2.4.1.1.9Scalars100ThermoBOperationalStatusread-onlydeprecatedThe operational status indicator for thermometer B. Valid values are: * withinOperationalRange - s100ThermoBTemperature is within its lower and upper threshold…
1.3.6.1.4.1.5504.2.4.1.2Identitysechtor100TrapscurrentAll Sechtor 100 MIB traps are defined under sechtor100Traps.
1.3.6.1.4.1.5504.2.4.1.2.0Identitysechtor100TrapsPrefixcurrentPrefix 0 for Sechtor 100 MIB traps as required by SNMPv2.
1.3.6.1.4.1.5504.2.4.1.2.0.1Notifications100FanStatusChangedeprecatedThis trap is generated whenever the value of s100FanOperationalStatus changes. This trap is deprecated and is replaced by sechtor100FanStatusChange.
1.3.6.1.4.1.5504.2.4.1.2.0.2Notifications100ThermoStatusChangedeprecatedThis trap is generated whenever sechtor100ThermoAOperationalStatus or sechtor100ThermoBOperationalStatus changes its value. This trap is deprecated and is repl…
1.3.6.1.4.1.5504.2.4.1.2.0.3Notificationsechtor100FanStatusChangecurrentThis trap is generated whenever the value of sechtor100FanOperationalStatus changes. The Sechtor 100 is identified by the shelf and slot number from instance O…
1.3.6.1.4.1.5504.2.4.1.2.0.4Notificationsechtor100ThermoStatusChangecurrentThis trap is generated whenever sechtor100ThermoAOperationalStatus or sechtor100ThermoBOperationalStatus changes its value. The Sechtor 100 is identified by th…
1.3.6.1.4.1.5504.2.4.1.3Tablesechtor100ConfigTablenot-accessiblecurrentThis table contains redundancy variables and environmental variables for monitoring fans and thermometers. For redundancy, the peer MAC address is maintained i…
1.3.6.1.4.1.5504.2.4.1.3.1Rowsechtor100ConfigEntrynot-accessiblecurrentAn entry in the sechtor100ConfigTable.
1.3.6.1.4.1.5504.2.4.1.3.1.1Columnsechtor100PeerMacAddressread-writecurrentThis is the Mac address of the peer s100 unit.
1.3.6.1.4.1.5504.2.4.1.3.1.2Columnsechtor100RedundancyEnableread-writecurrentWhether or not the redundancy functionality has been enabled. If this value is false, redundancy is not enable.
1.3.6.1.4.1.5504.2.4.1.3.1.3Columnsechtor100FanOperationalStatusread-onlycurrentThis variable describes the working status of the four fans for the Sechtor 100. If any one of the four fans is not running correctly, this variable shows 'fan…
1.3.6.1.4.1.5504.2.4.1.3.1.4Columnsechtor100ThermoAUpperThresholdread-writecurrentThis variable specifies the upper threshold for thermometer A in degrees Celsius. When s100ThermoATemperature is above this value, s100ThermoAOperationalStatus…
1.3.6.1.4.1.5504.2.4.1.3.1.5Columnsechtor100ThermoBUpperThresholdread-writecurrentThis variable specifies the upper threshold for thermometer B in degrees Celsius. When s100ThermoBTemperature is above this value, s100ThermoBOperationalStatus…
1.3.6.1.4.1.5504.2.4.1.3.1.6Columnsechtor100ThermoALowerThresholdread-writecurrentThis variable specifies the lower threshold for thermometer A in degrees Celsius. When s100ThermoATemperature is below this value, s100ThermoAOperationalStatus…
1.3.6.1.4.1.5504.2.4.1.3.1.7Columnsechtor100ThermoBLowerThresholdread-writecurrentThis variable specifies the lower threshold for thermometer B in degrees Celsius. When s100ThermoATemperature is below this value, s100ThermoBOperationalStatus…
1.3.6.1.4.1.5504.2.4.1.3.1.8Columnsechtor100ThermoATemperatureread-onlycurrentThe temperature in degrees Celsius read by the IC thermometer sensor A on the PCB board. It is effectively the internal ambient temperature inside the enclosur…
1.3.6.1.4.1.5504.2.4.1.3.1.9Columnsechtor100ThermoBTemperatureread-onlycurrentThe temperature in degrees Celsius read by the IC thermometer sensor B on the PCB board. It is effectively the internal ambient temperature inside the enclosur…
1.3.6.1.4.1.5504.2.4.1.3.1.10Columnsechtor100ThermoAOperationalStatusread-onlycurrentThe operational status indicator for thermometer A. Valid values are: * withinOperationalRange - s100ThermoATemperature is within its lower and upper threshold…
1.3.6.1.4.1.5504.2.4.1.3.1.11Columnsechtor100ThermoBOperationalStatusread-onlycurrentThe operational status indicator for thermometer B. Valid values are: * withinOperationalRange - s100ThermoBTemperature is within its lower and upper threshold…
1.3.6.1.4.1.5504.2.4.1.3.1.12Columnsechtor100RowStatusread-createcurrentUsed to control row creation and deletion. A row in this table is created using a single SNMP SET request with varbinds for: a) sechtor100RowStatus set to'Crea…
1.3.6.1.4.1.5504.6.19IdentityzhoneSechtor100MIB module for elements specific to Sechtor 100 products.