ZYXEL-MULTICAST-MIB
13 objects
The subtree for multicast
Imported Objects
| SNMPv2-SMI | -- RFC2578 MODULE-IDENTITY OBJECT-TYPE |
| ZYXEL-ES-SMI | esMgmt |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.890.1.15.3.54 | IdentityzyxelMulticast | The subtree for multicast | ||
| 1.3.6.1.4.1.890.1.15.3.54.1 | NodezyxelMulticastSetup | |||
| 1.3.6.1.4.1.890.1.15.3.54.1.1 | ScalarzyMulticastUnknownMulticastFrameForwarding | read-write | current | Specify the action to perform when the switch receives an unknown multicast frame. Unknown multicast frames are addressed to multicast groups for which the Swi… |
| 1.3.6.1.4.1.890.1.15.3.54.1.2 | ScalarzyMulticastReservedMulticastFrameForwarding | read-write | current | The IP address range of 224.0.0.0 to 224.0.0.255 are reserved for multicasting on the local network only. For example, 224.0.0.1 is for all hosts on a local ne… |
| 1.3.6.1.4.1.890.1.15.3.54.1.3 | ScalarzyMulticastUnknownMulticastFrameDropVlan1k | read-write | current | A string of octets containing one bit per VLAN. The first octet corresponds to VLANs with VlanIndex values 1 through 8; the second octet to VLANs 9 through 16 … |
| 1.3.6.1.4.1.890.1.15.3.54.1.4 | ScalarzyMulticastUnknownMulticastFrameDropVlan2k | read-write | current | A string of octets containing one bit per VLAN for VLANs with VlanIndex values 1025 through 2048. The first octet corresponds to VLANs with VlanIndex values 10… |
| 1.3.6.1.4.1.890.1.15.3.54.1.5 | ScalarzyMulticastUnknownMulticastFrameDropVlan3k | read-write | current | A string of octets containing one bit per VLAN for VLANs with VlanIndex values 2049 through 3072. The first octet corresponds to VLANs with VlanIndex values of… |
| 1.3.6.1.4.1.890.1.15.3.54.1.6 | ScalarzyMulticastUnknownMulticastFrameDropVlan4k | read-write | current | A string of octets containing one bit per VLAN for VLANs with VlanIndex values 3073 through 4094. The first octet corresponds to VLANs with VlanIndex values 30… |
| 1.3.6.1.4.1.890.1.15.3.54.1.7 | ScalarzyMulticastUnknownMulticastFrameToQuerierPort | read-write | current | When zyMulticastUnknownMulticastFrameForwarding is drop or drop-vlan and the switch receives an unknown multicast frame, the action will work on the switch. Un… |
| 1.3.6.1.4.1.890.1.15.3.54.1.8 | ScalarzyMulticastUnknownMulticastFrameToQuerierPortForwardingVlan1k | read-write | current | A string of octets containing one bit per VLAN. The first octet corresponds to VLANs with VlanIndex values 1 through 8; the second octet to VLANs 9 through 16 … |
| 1.3.6.1.4.1.890.1.15.3.54.1.9 | ScalarzyMulticastUnknownMulticastFrameToQuerierPortForwardingVlan2k | read-write | current | A string of octets containing one bit per VLAN for VLANs with VlanIndex values 1025 through 2048. The first octet corresponds to VLANs with VlanIndex values 10… |
| 1.3.6.1.4.1.890.1.15.3.54.1.10 | ScalarzyMulticastUnknownMulticastFrameToQuerierPortForwardingVlan3k | read-write | current | A string of octets containing one bit per VLAN for VLANs with VlanIndex values 2049 through 3072. The first octet corresponds to VLANs with VlanIndex values of… |
| 1.3.6.1.4.1.890.1.15.3.54.1.11 | ScalarzyMulticastUnknownMulticastFrameToQuerierPortForwardingVlan4k | read-write | current | A string of octets containing one bit per VLAN for VLANs with VlanIndex values 3073 through 4094. The first octet corresponds to VLANs with VlanIndex values 30… |