ZYXEL-POWER-ETHERNET-MIB
49 objects
The subtree for Power over Ethernet (PoE)
Imported Objects
| BRIDGE-MIB | dot1dBasePort |
| IF-MIB | ifIndex |
| INET-ADDRESS-MIB | InetAddress InetAddressType |
| P-BRIDGE-MIB | EnabledStatus |
| SNMPv2-SMI | -- RFC2578 MODULE-IDENTITY -- RFC2863 NOTIFICATION-TYPE OBJECT-TYPE |
| SNMPv2-TC | -- RFC2851 RowStatus DisplayString |
| ZYXEL-ES-SMI | -- RFC2579 esMgmt |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.890.1.15.3.59 | IdentityzyxelPoe | The subtree for Power over Ethernet (PoE) | ||
| 1.3.6.1.4.1.890.1.15.3.59.1 | NodezyxelPoeSetup | |||
| 1.3.6.1.4.1.890.1.15.3.59.1.1 | ScalarzyPoeMode | read-write | current | Set POE Mode Setup Consumption mode (0), Classification mode (1). |
| 1.3.6.1.4.1.890.1.15.3.59.1.2 | TablezyxelPoePsePortTable | not-accessible | current | The table contains power ethernet port information. |
| 1.3.6.1.4.1.890.1.15.3.59.1.2.1 | RowzyxelPoePsePortEntry | not-accessible | current | An entry contains power ethernet port information. |
| 1.3.6.1.4.1.890.1.15.3.59.1.2.1.1 | ColumnzyPoePsePortMaxPower | read-write | current | PoE PSE port user-defined max power expressed in milliwatt, Valid value should be between 1000 and 33000,in steps of 200. Value 0(Default) means to disable use… |
| 1.3.6.1.4.1.890.1.15.3.59.1.2.1.2 | ColumnzyPoePsePowerUp | read-write | current | Set PoE Power Up Mode Setup 802.3af mode (0), Legacy mode (1), Pre-802.3at mode(2), 802.3at mode(3), 802.3bt mode(4), Pre-802.3bt mode(5), Force-802.3at mode(6) |
| 1.3.6.1.4.1.890.1.15.3.59.1.2.1.3 | ColumnzyPoePsePortTimeRange | read-write | current | Time-Based PoE allow to schedule the PoE works time. Type in the time-range name witch is already created. |
| 1.3.6.1.4.1.890.1.15.3.59.1.2.1.4 | ColumnzyPoePseWideRangeDetection | read-write | current | Set PoE Wide range detection Enable/Disable. |
| 1.3.6.1.4.1.890.1.15.3.59.1.3 | ScalarzyPoePreAllocate | read-write | current | Set Poe pre-allocate Enable/Disable. |
| 1.3.6.1.4.1.890.1.15.3.59.1.4 | ScalarzyPoeDualDetection | read-write | current | Set Poe dual detection Enable/Disable. |
| 1.3.6.1.4.1.890.1.15.3.59.1.5 | ScalarzyPoePowerSequenceDelay | read-write | current | Set Poe Power Sequence Mode Delay Setup Enable/Disable. |
| 1.3.6.1.4.1.890.1.15.3.59.1.6 | TablezyxelPoePsePortTimeRangeTable | not-accessible | current | The table contains power ethernet port time-range settings. |
| 1.3.6.1.4.1.890.1.15.3.59.1.6.1 | RowzyxelPoePsePortTimeRangeEntry | not-accessible | current | An entry contains power ethernet port time-range settings. |
| 1.3.6.1.4.1.890.1.15.3.59.1.6.1.1 | ColumnzyPoePsePortTimeRangeName | read-only | current | Time-Based PoE allow to schedule the PoE works time. Specifiy the time-range which is already created. |
| 1.3.6.1.4.1.890.1.15.3.59.1.6.1.2 | ColumnzyPoePsePortTimeRangeRowStatus | read-create | current | This object allow entry to be create and deleted a poe port time-range entry. |
| 1.3.6.1.4.1.890.1.15.3.59.1.7 | ScalarzyPoeContinuousPoE | read-write | current | Set Continuous PoE Enable/Disable. |
| 1.3.6.1.4.1.890.1.15.3.59.2 | NodezyxelPoeStatus | |||
| 1.3.6.1.4.1.890.1.15.3.59.2.1 | TablezyxelPoePsePortInfoTable | not-accessible | current | The table contains power ethernet port information. |
| 1.3.6.1.4.1.890.1.15.3.59.2.1.1 | RowzyxelPoePsePortInfoEntry | not-accessible | current | An entry contains power ethernet port information. |
| 1.3.6.1.4.1.890.1.15.3.59.2.1.1.1 | ColumnzyPoePsePortInfoPowerConsumption | read-only | current | PoE PSE port power consumption expressed in milliwatt. |
| 1.3.6.1.4.1.890.1.15.3.59.2.1.1.2 | ColumnzyPoePsePortTimeRangeState | read-only | current | None(0): not bind with any time range. In(1): system time is in the time range. Out(2): system time is out of the time range. |
| 1.3.6.1.4.1.890.1.15.3.59.2.1.1.3 | ColumnzyPoePsePortTimeRangeInProfile | read-only | current | time-range profile name which is in profile |
| 1.3.6.1.4.1.890.1.15.3.59.3 | NodezyxelPoeTrapInfoObject | |||
| 1.3.6.1.4.1.890.1.15.3.59.3.1 | ScalarzyPoeTrapPsePowerSupplyFailedReason | not-accessible | current | Internal-power-supply-for-PoE-failed(0): Internal power supply for PoE has failed. RPS-for-PoE-failed(1): External power supply for PoE (RPS) has failed. RPS-f… |
| 1.3.6.1.4.1.890.1.15.3.59.4 | NodezyxelPoeNotifications | |||
| 1.3.6.1.4.1.890.1.15.3.59.4.1 | NotificationzyPoePowerPortOverload | current | Port is off, due to the overload state according to 802.3af. | |
| 1.3.6.1.4.1.890.1.15.3.59.4.2 | NotificationzyPoePowerPortShortCircuit | current | Port is off, due to short circuit. | |
| 1.3.6.1.4.1.890.1.15.3.59.4.3 | NotificationzyPoePowerPortOverSystemBudget | current | Port is off, due to over system budget. | |
| 1.3.6.1.4.1.890.1.15.3.59.4.4 | NotificationzyPoePsePowerSupplyFailed | current | PSE power supply failed, due to the reason of zyxelPoeTrapPsePowerSupplyFailedReason. | |
| 1.3.6.1.4.1.890.1.15.3.59.4.5 | NotificationzyPoePowerPortOverloadRecovered | current | Port is on, since recovered from overload state. | |
| 1.3.6.1.4.1.890.1.15.3.59.4.6 | NotificationzyPoePowerPortShortCircuitRecovered | current | Port is on, since recovered from short circuit. | |
| 1.3.6.1.4.1.890.1.15.3.59.4.7 | NotificationzyPoePowerPortOverSystemBudgetRecovered | current | Port is on, since recovered from over system budget. | |
| 1.3.6.1.4.1.890.1.15.3.59.4.8 | NotificationzyPoeAutoPdRecoveryAlarm | current | PoE device works fail. | |
| 1.3.6.1.4.1.890.1.15.3.59.4.9 | NotificationzyPoePowerPortOverStandard | current | Port uses more power than standard defined value. | |
| 1.3.6.1.4.1.890.1.15.3.59.5 | NodezyxelPoeAutoPdRecoverySetup | |||
| 1.3.6.1.4.1.890.1.15.3.59.5.1 | ScalarzyPoeAutoPdRecoveryState | read-write | current | Enable or disable Auto PD Recovery on switch. |
| 1.3.6.1.4.1.890.1.15.3.59.5.2 | TablezyxelPoeAutoPdRecoveryPortTable | not-accessible | current | The table contains Auto PD Recovery port configuration. |
| 1.3.6.1.4.1.890.1.15.3.59.5.2.1 | RowzyxelPoeAutoPdRecoveryPortEntry | not-accessible | current | The entry contains Auto PD Recovery port configuration. |
| 1.3.6.1.4.1.890.1.15.3.59.5.2.1.1 | ColumnzyPoeAutoPdRecoveryPortState | read-write | current | Enable or disable Auto PD Recovery on specific port. |
| 1.3.6.1.4.1.890.1.15.3.59.5.2.1.2 | ColumnzyPoeAutoPdRecoveryPortMode | read-write | current | Auto PD Recovery mode. Default value is LLDP(1). |
| 1.3.6.1.4.1.890.1.15.3.59.5.2.1.3 | ColumnzyPoeAutoPdRecoveryPortIpAddressType | read-write | current | The address type of zyPoeAutoPdRecoveryPortIpAddress. |
| 1.3.6.1.4.1.890.1.15.3.59.5.2.1.4 | ColumnzyPoeAutoPdRecoveryPortIpAddress | read-write | current | PD IP address. |
| 1.3.6.1.4.1.890.1.15.3.59.5.2.1.5 | ColumnzyPoeAutoPdRecoveryPollingInterval | read-write | current | Time interval between each ping request to PD. Default value is 20 (seconds). |
| 1.3.6.1.4.1.890.1.15.3.59.5.2.1.6 | ColumnzyPoeAutoPdRecoveryPortPollingCount | read-write | current | Number of retry times when detect fail. Default value is 3 (times). |
| 1.3.6.1.4.1.890.1.15.3.59.5.2.1.7 | ColumnzyPoeAutoPdRecoveryPortAction | read-write | current | Action will be applied if PD without any response. Default value is reboot-alarm(1) |
| 1.3.6.1.4.1.890.1.15.3.59.5.2.1.8 | ColumnzyPoeAutoPdRecoveryPortResumePollingInterval | read-write | current | PD reboot waiting time. Default value is 600 (seconds). |
| 1.3.6.1.4.1.890.1.15.3.59.5.2.1.9 | ColumnzyPoeAutoPdRecoveryPortPdRebootCount | read-write | current | PD reboot count. Default value is 1 (time). |
| 1.3.6.1.4.1.890.1.15.3.59.5.2.1.10 | ColumnzyPoeAutoPdRecoveryPortResumePowerInterval | read-write | current | Set delay time to resume the PoE power supply. Default value is 10 (seconds). |