ZYXELVDSL
263 objects
No module-level DESCRIPTION found.
Imported Objects
| RFC-1215 | TRAP-TYPE |
| RFC1155-SMI | Counter enterprises Gauge TimeTicks |
| RFC1213-MIB | DisplayString |
| SNMPv2-SMI | OBJECT-TYPE |
| SNMPv2-TC | MacAddress RowStatus |
| ZYXEL-MIB | vesSeriesCommon |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.890.1.5.12.1.1 | NodeaccessSwitchVdslLineMib | |||
| 1.3.6.1.4.1.890.1.5.12.1.1.1 | NodeaccessSwitchVdslLineMibObjects | |||
| 1.3.6.1.4.1.890.1.5.12.1.1.1.1 | TableaccessSwitchVdslLineTable | not-accessible | mandatory | This table includes common attributes describing both ends of the line. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.1.1 | RowaccessSwitchVdslLineEntry | not-accessible | mandatory | An entry in the accessSwitchVdslLineTable. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.1.1.1 | ColumnaccessSwitchVdslLineCoding | read-only | mandatory | Specifies the VDSL coding type used on this line. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.1.1.2 | ColumnaccessSwitchVdslLineDiscCount | read-only | mandatory | Count of the number of disconnection failures since agent reset. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.1.1.3 | ColumnaccessSwitchVdslLineConfProfile | read-only | mandatory | The value of this object identifies the row in the VDSL Line Configuration Profile Table, (accessSwitchVdslLineConfProfileTable), which applies for this VDSL l… |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.1.1.4 | ColumnaccessSwitchVdslLineType | read-only | current | Defines the type of VDSL physical line entity that exists, by defining whether and how the line is channelized. If the line is channelized, the value will be o… |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.2 | TableaccessSwitchVdslVtuoPhysTable | not-accessible | mandatory | This table provides one row for each VTU-O. Each row contains the physical layer parameters for that VTU-O. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.2.1 | RowaccessSwitchVdslVtuoPhysEntry | not-accessible | mandatory | An entry in the accessSwitchVdslVtuoPhysTable. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.2.1.1 | ColumnaccessSwitchVdslVtuoCurrSnrMgn | read-only | mandatory | Noise Margin as seen by this VTU with respect to its received signal in 0.01dB. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.2.1.2 | ColumnaccessSwitchVdslVtuoCurrMse | read-only | mandatory | Minimum Square Error as seen by this VTU with respect to its received signal in 0.01dB. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.2.1.3 | ColumnaccessSwitchVdslVtuoCurrPsd | read-only | mandatory | Power Spectral Density as seen by this VTU with respect to its received signal in -0.01dBm/Hz. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.2.1.4 | ColumnaccessSwitchVdslVtuoCurrRsErr | read-only | mandatory | Reed-Solomon error counted by this VTU with respect to its received signal. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.2.1.5 | ColumnaccessSwitchVdslVtuoCurrAtn | read-only | mandatory | Measured difference in the total power transmitted by the peer VTU and the total power received by this VTU. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.2.1.6 | ColumnaccessSwitchVdslVtuoCurrOutputPwr | read-only | mandatory | Measured total output power in 0.01dBm transmitted by this VTU. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.2.1.7 | ColumnaccessSwitchVdslVtuoCurrRate | read-only | mandatory | Actual transmission rate in bits-per-second on this line. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.2.1.8 | ColumnaccessSwitchVdslVtuoChanCurrLineRate | read-only | current | Actual transmit rate of downstream from VTUC. This value is in units of bps. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.2.1.9 | ColumnaccessSwitchVdslVtuoCurrAttainableRate | read-only | mandatory | Indicates the maximum mandatoryly attainable data rate in bits-per-second by the VTU. This value will be equal or greater than the mandatory line rate. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.2.1.10 | ColumnaccessSwitchVdslVtuoCurrStatus | read-only | mandatory | Indicates mandatory state of the VTU-O line. This is a bit-map of possible conditions. The various bit positions are: 0 noDefect There no defects on the line 1… |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.3 | TableaccessSwitchVdslVturPhysTable | not-accessible | mandatory | This table provides one row for each VTU-R. Each row contains the physical layer parameters for that VTU-R. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.3.1 | RowaccessSwitchVdslVturPhysEntry | not-accessible | mandatory | An entry in the accessSwitchVdslVturPhysTable. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.3.1.1 | ColumnaccessSwitchVdslVturCurrSnrMgn | read-only | mandatory | Noise Margin as seen by this VTU with respect to its received signal in 0.01dB. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.3.1.2 | ColumnaccessSwitchVdslVturCurrMse | read-only | mandatory | Minimum Square Error as seen by this VTU with respect to its received signal in 0.01dB. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.3.1.3 | ColumnaccessSwitchVdslVturCurrPsd | read-only | mandatory | Power Spectral Density as seen by this VTU with respect to its received signal in -0.01dBm/Hz. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.3.1.4 | ColumnaccessSwitchVdslVturCurrRsErr | read-only | mandatory | Reed-Solomon error counted by this VTU with respect to its received signal. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.3.1.5 | ColumnaccessSwitchVdslVturCurrAtn | read-only | mandatory | Measured difference in the total power transmitted by the peer VTU and the total power received by this VTU. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.3.1.6 | ColumnaccessSwitchVdslVturCurrOutputPwr | read-only | mandatory | Measured total output power in 0.01dBm transmitted by this VTU. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.3.1.7 | ColumnaccessSwitchVdslVturCurrRate | read-only | mandatory | Actual transmission rate in bits-per-second on this line. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.3.1.8 | ColumnaccessSwitchVdslVturChanCurrLineRate | read-only | current | Actual transmit rate of upstream from VTUR. This value is in units of bps. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.3.1.9 | ColumnaccessSwitchVdslVturCurrAttainableRate | read-only | mandatory | Indicates the maximum mandatoryly attainable data rate in bits-per-second by the VTU. This value will be equal or greater than the mandatory line rate. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.3.1.10 | ColumnaccessSwitchVdslVturCurrStatus | read-only | mandatory | Indicates mandatory state of the VTU-R line. This is a bit-map of possible conditions. The various bit positions are: 0 noDefect There no defects on the line 1… |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.4 | TableaccessSwitchVdslVtuoInventoryTable | not-accessible | mandatory | This table provides one row for each VTU-O. Each row contains the inventory parameters for that VTU-O. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.4.1 | RowaccessSwitchVdslVtuoInventoryEntry | not-accessible | mandatory | An entry in the accessSwitchVdslVtuoInventoryTable. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.4.1.1 | ColumnaccessSwitchVdslVtuoInvSerialNumber | read-only | mandatory | The vendor specific string that identifies the vendor equipment. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.4.1.2 | ColumnaccessSwitchVdslVtuoInvVendorID | read-only | mandatory | The vendor ID code is a copy of the binary vendor identification field defined by the PHY[10] and expressed as readable characters. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.4.1.3 | ColumnaccessSwitchVdslVtuoInvVersionNumber | read-only | mandatory | The vendor specific version number sent by this VTU as part of the initialization messages. It is a copy of the binary version number field defined by the PHY[… |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.5 | TableaccessSwitchVdslVturInventoryTable | not-accessible | mandatory | This table provides one row for each VTU-R. Each row contains the inventory parameters for that VTU-R. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.5.1 | RowaccessSwitchVdslVturInventoryEntry | not-accessible | mandatory | An entry in the accessSwitchVdslVturInventoryTable. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.5.1.1 | ColumnaccessSwitchVdslVturInvSerialNumber | read-only | mandatory | The vendor specific string that identifies the vendor equipment. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.5.1.2 | ColumnaccessSwitchVdslVturInvVendorID | read-only | mandatory | The vendor ID code is a copy of the binary vendor identification field defined by the PHY[10] and expressed as readable characters. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.5.1.3 | ColumnaccessSwitchVdslVturInvVersionNumber | read-only | mandatory | The vendor specific version number sent by this VTU as part of the initialization messages. It is a copy of the binary version number field defined by the PHY[… |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.6 | TableaccessSwitchVdslVtuoPerfDataTable | not-accessible | mandatory | This table provides one row for each VTU-O. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.6.1 | RowaccessSwitchVdslVtuoPerfDataEntry | not-accessible | mandatory | An entry in accessSwitchVdslVtuoPerfDataTable. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.1 | ColumnaccessSwitchVdslVtuoPerfLofs | read-only | mandatory | Count of the number of Loss of Framing failures since agent reset. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.2 | ColumnaccessSwitchVdslVtuoPerfLoss | read-only | mandatory | Count of the number of Loss of Signal failures since agent reset. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.3 | ColumnaccessSwitchVdslVtuoPerfLols | read-only | mandatory | Count of the number of Loss of Link failures since agent reset. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.4 | ColumnaccessSwitchVdslVtuoPerfLprs | read-only | mandatory | Count of the number of Loss of Power failures since agent reset. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.5 | ColumnaccessSwitchVdslVtuoPerfESs | read-only | mandatory | Count of the number of Errored Seconds since agent reset. The errored second parameter is a count of one-second intervals containing one or more crc anomalies,… |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.6 | ColumnaccessSwitchVdslVtuoPerfInits | read-only | mandatory | Count of the line initialization attempts since agent reset. Includes both successful and failed attempts. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.7 | ColumnaccessSwitchVdslVtuoPerfValidIntervals | read-only | mandatory | The number of previous 15-minute intervals in the interval table for which data was collected. Given that <n> is the maximum # of intervals supported. The valu… |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.8 | ColumnaccessSwitchVdslVtuoPerfInvalidIntervals | read-only | mandatory | The number of intervals in the range from 0 to the value of accessSwitchVdslVtuoPerfValidIntervals for which no data is available. This object will typically b… |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.9 | ColumnaccessSwitchVdslVtuoPerfCurr15MinTimeElapsed | read-only | mandatory | Total elapsed seconds in this interval. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.10 | ColumnaccessSwitchVdslVtuoPerfCurr15MinLofs | read-only | mandatory | Count of seconds in the mandatory 15 minute interval when there was Loss of Framing. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.11 | ColumnaccessSwitchVdslVtuoPerfCurr15MinLoss | read-only | mandatory | Count of seconds in the mandatory 15 minute interval when there was Loss of Signal. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.12 | ColumnaccessSwitchVdslVtuoPerfCurr15MinLols | read-only | mandatory | Count of seconds in the mandatory 15 minute interval when there was Loss of Link. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.13 | ColumnaccessSwitchVdslVtuoPerfCurr15MinLprs | read-only | mandatory | Count of seconds in the mandatory 15 minute interval when there was Loss of Power. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.14 | ColumnaccessSwitchVdslVtuoPerfCurr15MinESs | read-only | mandatory | Count of Errored Seconds in the mandatory 15 minute interval. The errored second parameter is a count of one-second intervals containing one or more crc anomal… |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.15 | ColumnaccessSwitchVdslVtuoPerfCurr15MinInits | read-only | mandatory | Count of the line initialization attempts in the mandatory 15 minute interval. Includes both successful and failed attempts. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.16 | ColumnaccessSwitchVdslVtuoPerfCurr1DayTimeElapsed | read-only | mandatory | Number of seconds that have elapsed since the beginning of the mandatory 1-day interval. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.17 | ColumnaccessSwitchVdslVtuoPerfCurr1DayLofs | read-only | mandatory | Count of the number of seconds when there was Loss of Framing during the mandatory day as measured by accessSwitchVdslVtuoPerfCurr1DayTimeElapsed. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.18 | ColumnaccessSwitchVdslVtuoPerfCurr1DayLoss | read-only | mandatory | Count of the number of seconds when there was Loss of Signal during the mandatory day as measured by accessSwitchVdslVtuoPerfCurr1DayTimeElapsed. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.19 | ColumnaccessSwitchVdslVtuoPerfCurr1DayLols | read-only | mandatory | Count of the number of seconds when there was Loss of Link during the mandatory day as measured by accessSwitchVdslVtuoPerfCurr1DayTimeElapsed. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.20 | ColumnaccessSwitchVdslVtuoPerfCurr1DayLprs | read-only | mandatory | Count of the number of seconds when there was Loss of Power during the mandatory day as measured by accessSwitchVdslVtuoPerfCurr1DayTimeElapsed. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.21 | ColumnaccessSwitchVdslVtuoPerfCurr1DayESs | read-only | mandatory | Count of Errored Seconds during the mandatory day as measured by accessSwitchVdslVtuoPerfCurr1DayTimeElapsed. The errored second parameter is a count of one-se… |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.22 | ColumnaccessSwitchVdslVtuoPerfCurr1DayInits | read-only | mandatory | Count of the line initialization attempts in the day as measured by accessSwitchVdslVtuoPerfCurr1DayTimeElapsed. Includes both successful and failed attempts. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.23 | ColumnaccessSwitchVdslVtuoPerfPrev1DayMoniSecs | read-only | mandatory | The amount of time in the previous 1-day interval over which the performance monitoring information is actually counted. This value will be the same as the int… |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.24 | ColumnaccessSwitchVdslVtuoPerfPrev1DayLofs | read-only | mandatory | Count of seconds in the interval when there was Loss of Framing within the most recent previous 1-day period. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.25 | ColumnaccessSwitchVdslVtuoPerfPrev1DayLoss | read-only | mandatory | Count of seconds in the interval when there was Loss of Signal within the most recent previous 1-day period. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.26 | ColumnaccessSwitchVdslVtuoPerfPrev1DayLols | read-only | mandatory | Count of seconds in the interval when there was Loss of Link within the most recent previous 1-day period. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.27 | ColumnaccessSwitchVdslVtuoPerfPrev1DayLprs | read-only | mandatory | Count of seconds in the interval when there was Loss of Power within the most recent previous 1-day period. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.28 | ColumnaccessSwitchVdslVtuoPerfPrev1DayESs | read-only | mandatory | Count of Errored Seconds within the most recent previous 1-day period. The errored second parameter is a count of one-second intervals containing one or more c… |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.29 | ColumnaccessSwitchVdslVtuoPerfPrev1DayInits | read-only | mandatory | Count of the line initialization attempts in the most recent previous 1-day period. Includes both successful and failed attempts. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.30 | ColumnaccessSwitchVdslVtuoPerfBerr | read-only | current | Count of the number of Over limited error sencond since agent reset. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.31 | ColumnaccessSwitchVdslVtuoPerfBmin | read-only | current | Count of the number of Under Min Margin since agent reset. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.7 | TableaccessSwitchVdslVturPerfDataTable | not-accessible | mandatory | This table provides one row for each VTU-R. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.7.1 | RowaccessSwitchVdslVturPerfDataEntry | not-accessible | mandatory | An entry in accessSwitchVdslVturPerfDataTable. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.7.1.1 | ColumnaccessSwitchVdslVturPerfLofs | read-only | mandatory | Count of the number of Loss of Framing failures since agent reset. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.7.1.2 | ColumnaccessSwitchVdslVturPerfLoss | read-only | mandatory | Count of the number of Loss of Signal failures since agent reset. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.7.1.3 | ColumnaccessSwitchVdslVturPerfLprs | read-only | mandatory | Count of the number of Loss of Power failures since agent reset. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.7.1.4 | ColumnaccessSwitchVdslVturPerfESs | read-only | mandatory | Count of the number of Errored Seconds since agent reset. The errored second parameter is a count of one-second intervals containing one or more crc anomalies,… |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.7.1.5 | ColumnaccessSwitchVdslVturPerfValidIntervals | read-only | mandatory | The number of previous 15-minute intervals in the interval table for which data was collected. Given that <n> is the maximum # of intervals supported. The valu… |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.7.1.6 | ColumnaccessSwitchVdslVturPerfInvalidIntervals | read-only | mandatory | The number of intervals in the range from 0 to the value of accessSwitchVdslVturPerfValidIntervals for which no data is available. This object will typically b… |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.7.1.7 | ColumnaccessSwitchVdslVturPerfCurr15MinTimeElapsed | read-only | mandatory | Total elapsed seconds in this interval. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.7.1.8 | ColumnaccessSwitchVdslVturPerfCurr15MinLofs | read-only | mandatory | Count of seconds in the mandatory 15 minute interval when there was Loss of Framing. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.7.1.9 | ColumnaccessSwitchVdslVturPerfCurr15MinLoss | read-only | mandatory | Count of seconds in the mandatory 15 minute interval when there was Loss of Signal. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.7.1.10 | ColumnaccessSwitchVdslVturPerfCurr15MinLprs | read-only | mandatory | Count of seconds in the mandatory 15 minute interval when there was Loss of Power. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.7.1.11 | ColumnaccessSwitchVdslVturPerfCurr15MinESs | read-only | mandatory | Count of Errored Seconds in the mandatory 15 minute interval. The errored second parameter is a count of one-second intervals containing one or more crc anomal… |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.7.1.12 | ColumnaccessSwitchVdslVturPerfCurr1DayTimeElapsed | read-only | mandatory | Number of seconds that have elapsed since the beginning of the mandatory 1-day interval. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.7.1.13 | ColumnaccessSwitchVdslVturPerfCurr1DayLofs | read-only | mandatory | Count of the number of seconds when there was Loss of Framing during the mandatory day as measured by accessSwitchVdslVturPerfCurr1DayTimeElapsed. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.7.1.14 | ColumnaccessSwitchVdslVturPerfCurr1DayLoss | read-only | mandatory | Count of the number of seconds when there was Loss of Signal during the mandatory day as measured by accessSwitchVdslVturPerfCurr1DayTimeElapsed. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.7.1.15 | ColumnaccessSwitchVdslVturPerfCurr1DayLprs | read-only | mandatory | Count of the number of seconds when there was Loss of Power during the mandatory day as measured by accessSwitchVdslVturPerfCurr1DayTimeElapsed. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.7.1.16 | ColumnaccessSwitchVdslVturPerfCurr1DayESs | read-only | mandatory | Count of Errored Seconds during the mandatory day as measured by accessSwitchVdslVturPerfCurr1DayTimeElapsed. The errored second parameter is a count of one-se… |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.7.1.17 | ColumnaccessSwitchVdslVturPerfPrev1DayMoniSecs | read-only | mandatory | The amount of time in the previous 1-day interval over which the performance monitoring information is actually counted. This value will be the same as the int… |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.7.1.18 | ColumnaccessSwitchVdslVturPerfPrev1DayLofs | read-only | mandatory | Count of seconds in the interval when there was Loss of Framing within the most recent previous 1-day period. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.7.1.19 | ColumnaccessSwitchVdslVturPerfPrev1DayLoss | read-only | mandatory | Count of seconds in the interval when there was Loss of Signal within the most recent previous 1-day period. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.7.1.20 | ColumnaccessSwitchVdslVturPerfPrev1DayLprs | read-only | mandatory | Count of seconds in the interval when there was Loss of Power within the most recent previous 1-day period. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.7.1.21 | ColumnaccessSwitchVdslVturPerfPrev1DayESs | read-only | mandatory | Count of Errored Seconds within the most recent previous 1-day period. The errored second parameter is a count of one-second intervals containing one or more c… |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.7.1.22 | ColumnaccessSwitchVdslVturPerfBerr | read-only | current | Count of the number of Over limited error seconds agent reset. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.7.1.23 | ColumnaccessSwitchVdslVturPerfBmin | read-only | current | Count of the number of Under Min Margin since agent reset. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.8 | TableaccessSwitchVdslVtuoIntervalTable | not-accessible | mandatory | This table provides one row for each VTU-O performance data collection interval. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.8.1 | RowaccessSwitchVdslVtuoIntervalEntry | not-accessible | mandatory | An entry in the accessSwitchVdslVtuoIntervalTable. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.8.1.1 | ColumnaccessSwitchVdslVtuoIntervalNumber | not-accessible | mandatory | Performance Data Interval number 1 is the the most recent previous interval; interval 96 is 24 hours ago. Intervals 2..96 are optional. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.8.1.2 | ColumnaccessSwitchVdslVtuoIntervalLofs | read-only | mandatory | Count of seconds in the interval when there was Loss of Framing. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.8.1.3 | ColumnaccessSwitchVdslVtuoIntervalLoss | read-only | mandatory | Count of seconds in the interval when there was Loss of Signal. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.8.1.4 | ColumnaccessSwitchVdslVtuoIntervalLols | read-only | mandatory | Count of seconds in the interval when there was Loss of Link. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.8.1.5 | ColumnaccessSwitchVdslVtuoIntervalLprs | read-only | mandatory | Count of seconds in the interval when there was Loss of Power. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.8.1.6 | ColumnaccessSwitchVdslVtuoIntervalESs | read-only | mandatory | Count of Errored Seconds in the interval. The errored second parameter is a count of one-second intervals containing one or more crc anomalies, or one or more … |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.8.1.7 | ColumnaccessSwitchVdslVtuoIntervalInits | read-only | mandatory | Count of the line initialization attempts during the interval. Includes both successful and failed attempts. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.8.1.8 | ColumnaccessSwitchVdslVtuoIntervalValidData | read-only | mandatory | This variable indicates if the data for this interval is valid. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.8.1.9 | ColumnaccessSwitchVdslVtucIntervalBerr | read-only | current | No of times in the interval when there was Over errored seconds. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.8.1.10 | ColumnaccessSwitchVdslVtucIntervalBmin | read-only | current | No of times in the interval when there was Under Min Margin. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.9 | TableaccessSwitchVdslVturIntervalTable | not-accessible | mandatory | This table provides one row for each VTU-R performance data collection interval. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.9.1 | RowaccessSwitchVdslVturIntervalEntry | not-accessible | mandatory | An entry in the accessSwitchVdslVturIntervalTable. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.9.1.1 | ColumnaccessSwitchVdslVturIntervalNumber | not-accessible | mandatory | Performance Data Interval number 1 is the the most recent previous interval; interval 96 is 24 hours ago. Intervals 2..96 are optional. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.9.1.2 | ColumnaccessSwitchVdslVturIntervalLofs | read-only | mandatory | Count of seconds in the interval when there was Loss of Framing. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.9.1.3 | ColumnaccessSwitchVdslVturIntervalLoss | read-only | mandatory | Count of seconds in the interval when there was Loss of Signal. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.9.1.4 | ColumnaccessSwitchVdslVturIntervalLprs | read-only | mandatory | Count of seconds in the interval when there was Loss of Power. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.9.1.5 | ColumnaccessSwitchVdslVturIntervalESs | read-only | mandatory | Count of Errored Seconds in the interval. The errored second parameter is a count of one-second intervals containing one or more crc anomalies, or one or more … |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.9.1.6 | ColumnaccessSwitchVdslVturIntervalValidData | read-only | mandatory | This variable indicates if the data for this interval is valid. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.9.1.7 | ColumnaccessSwitchVdslVturIntervalBerr | read-only | current | No of times in the interval when there was Over limited error seconds. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.9.1.8 | ColumnaccessSwitchVdslVturIntervalBmin | read-only | current | No of times in the interval when there was Under Min Margin. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.10 | TableaccessSwitchVdslLineConfProfileTable | not-accessible | mandatory | This table contains information on the VDSL line configuration. One entry in this table reflects a profile which can be used to configure the VDSL line. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.10.1 | RowaccessSwitchVdslLineConfProfileEntry | not-accessible | mandatory | Each entry consists of a list of parameters that represents the configuration of an VDSL modem. When `dynamic' profiles are implemented, a default profile will… |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.1 | ColumnaccessSwitchVdslLineConfProfileName | not-accessible | mandatory | This object is used by the line configuration table in order to identify a row of this table. When `dynamic' profiles are implemented, the profile name is user… |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.2 | ColumnaccessSwitchVdslLineConfMode | read-only | mandatory | Specifies the VDSL mode type used on this line. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.3 | ColumnaccessSwitchVdslVtuoConfRate | read-create | mandatory | Transmission rate in bits-per-second specified by this VTU. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.4 | ColumnaccessSwitchVdslVtuoConfTargetSnrMgn | read-only | mandatory | Configured Target Signal/Noise Margin in 0.01dB. This is the Noise Margin the modem must achieve with a BER of 10-7 or better to successfully complete initiali… |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.5 | ColumnaccessSwitchVdslVtuoConfMaxSnrMgn | read-only | mandatory | Configured Maximum acceptable Signal/Noise Margin in 0.01dB. If the Noise Margin is above this the modem should attempt to reduce its power output to optimize … |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.6 | ColumnaccessSwitchVdslVtuoConfMinSnrMgn | read-only | mandatory | Configured Minimum acceptable Signal/Noise Margin in 0.01dB. If the noise margin falls below this level, the modem should attempt to increase its power output.… |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.7 | ColumnaccessSwitchVdslVturConfRate | read-only | mandatory | Transmission rate in bits-per-second specified by this VTU. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.8 | ColumnaccessSwitchVdslVturConfTargetSnrMgn | read-only | mandatory | Configured Target Signal/Noise Margin in 0.01dB. This is the Noise Margin the modem must achieve with a BER of 10-7 or better to successfully complete initiali… |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.9 | ColumnaccessSwitchVdslVturConfMaxSnrMgn | read-only | mandatory | Configured Maximum acceptable Signal/Noise Margin in 0.01dB. If the Noise Margin is above this the modem should attempt to reduce its power output to optimize … |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.10 | ColumnaccessSwitchVdslVturConfMinSnrMgn | read-only | mandatory | Configured Minimum acceptable Signal/Noise Margin in 0.01dB. If the noise margin falls below this level, the modem should attempt to increase its power output.… |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.11 | ColumnaccessSwitchVdslLineConfProfileRowStatus | read-create | mandatory | This object is used to create a new row or modify or delete an existing row in this table. A profile activated by setting this object to `active'. When `active… |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.13 | ColumnaccessSwitchVdslConfRateAdaptiveMode | read-write | current | Set rate adptive mode as decrease mode or decrease & increase mode. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.14 | ColumnaccessSwitchVdslVtuoConfInterleaveMaxLineRate | read-only | current | Configured Maximum Transmit payload rate for `Interleave' channels, in bps. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.15 | ColumnaccessSwitchVdslVtuoConfInterleaveMinLineRate | read-only | current | Configured Minimum Transmit payload rate for `Interleave' channels, in bps. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.16 | ColumnaccessSwitchVdslVtuoConfMaxInterleaveDelay | read-only | current | Configured max. interleave delay of downstream. This value is in units of 0.5 ms. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.17 | ColumnaccessSwitchVdslVturConfInterleaveMaxLineRate | read-only | current | Configured Minimum Transmit payload rate for `Interleave' channels, in bps. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.18 | ColumnaccessSwitchVdslVturConfInterleaveMinLineRate | read-only | current | Configured Minimum Transmit payload rate for `Interleave' channels, in bps. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.19 | ColumnaccessSwitchVdslVturConfMaxInterleaveDelay | read-only | current | Configured max. interleave delay of downstream. This value is in units of 0.5 ms. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.20 | ColumnaccessSwitchVdslConfRFI | read-only | current | Set RFI Band function as disabled, standard or custom. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.21 | ColumnaccessSwitchVdslRFIBand1Low | read-only | current | Configured low of RFIBand1 function when custom RFI Band is used. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.22 | ColumnaccessSwitchVdslRFIBand1High | read-only | current | onfigured high of RFIBand1 function when custom RFI Band is used. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.23 | ColumnaccessSwitchVdslRFIBand2Low | read-only | current | Configured low of RFIBand2 function when custom RFI Band is used. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.24 | ColumnaccessSwitchVdslRFIBand2High | read-only | current | Configured high of RFIBand2 function when custom RFI Band is used. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.25 | ColumnaccessSwitchVdslRFIBand3Low | read-only | current | Configured low of RFIBand3 function when custom RFI Band is used. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.26 | ColumnaccessSwitchVdslRFIBand3High | read-only | current | Configured high of RFIBand3 function when custom RFI Band is used. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.27 | ColumnaccessSwitchVdslRFIBand4Low | read-only | current | Configured low of RFIBand4 function when custom RFI Band is used. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.28 | ColumnaccessSwitchVdslRFIBand4High | read-only | current | Configured high of RFIBand4 function when custom RFI Band is used. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.29 | ColumnaccessSwitchVdslConfCompatibleMode | read-only | current | Set compatible mode to TCM-ISDN(0) or ADSL(1). |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.30 | ColumnaccessSwitchVdslPowerCutback | read-only | current | Configured Power Cut Back. It is not supported in VES. Will be fixed at 0. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.11 | ScalarvesMaxNumOfProfiles | read-only | mandatory | The maximum number of VDSL profiles which the system supports. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.12 | TableaccessSwitchVdslVtucChanPerfDataTable | not-accessible | current | This table provides one row for each VTUC channel. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.12.1 | RowaccessSwitchVdslVtucChanPerfDataEntry | not-accessible | current | An entry in the accessSwitchVdslVturPerfDataTable. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.12.1.1 | ColumnaccessSwitchVdslVtucChanNumber | read-only | current | Channel Number of VDSL. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.12.1.2 | ColumnaccessSwitchVdslVtucChanRScorrectableBlks | read-only | current | Count of all blocks received with errors that were RS correctable since agent reset. These blocks are passed on as good data. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.12.1.3 | ColumnaccessSwitchvdslvtucChanCRCerrorBlks | read-only | current | Count of all blocks received with CRC errors since agent reset. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.13 | TableaccessSwitchVdslVturChanPerfDataTable | not-accessible | current | This table provides one row for each VTUR channel. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.13.1 | RowaccessSwitchVdslVturChanPerfDataEntry | not-accessible | current | An entry in the accessSwitchVdslVturPerfDataTable. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.13.1.1 | ColumnaccessSwitchVdslVturChanNumber | read-only | current | Channel Number of VDSL. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.13.1.2 | ColumnaccessSwitchVdslVturChanRScorrectableBlks | read-only | current | Count of all blocks received with errors that were RS correctable since agent reset. These blocks are passed on as good data. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.13.1.3 | ColumnaccessSwitchVdslVturChanCRCerrorBlks | read-only | current | Count of all blocks received with CRC errors since agent reset. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.14 | TableaccessSwitchVturDevTable | not-accessible | current | Port remote information table |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.14.1 | RowaccessSwitchVturDevEntry | not-accessible | current | Port remote information - node for the information of the remote equipment |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.14.1.1 | ColumnaccessSwitchVturDevName | read-only | current | This object indicates the remote device name. Get by setting accessSwitchVturDevConfGet to (1) |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.14.1.2 | ColumnaccessSwitchVturDevVersion | read-only | current | This object indicates the remote device software version. Get by setting accessSwitchVturDevConfGet to (1) |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.14.1.3 | ColumnaccessSwitchVturDevID | read-only | current | This object indicates the remote device ID. Get by setting accessSwitchVturDevConfGet to (1) |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.14.1.4 | ColumnaccessSwitchVturDevConfGet | read-write | current | Set to '1' to get name and version of remote equipment. Setting the object to '2' has no effect. This object always returns '2' when read. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.14.1.5 | ColumnaccessSwitchVturReset | read-only | current | Set to '1' to reset the remote equipment. Setting the object to '2' has no effect. This object always returns '2' when read. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.14.1.6 | ColumnaccessSwitchVturResetVdsl | read-only | current | Set to '1' to reset the remote VDSL line. Setting the object to '2' has no effect. This object always returns '2' when read. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.15 | TableaccessSwitchVturConfTable | not-accessible | current | port remote equipment information table |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.15.1 | RowaccessSwitchVturConfEntry | not-accessible | current | Port remote equipment entry - node for the equipment information of the remote |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.15.1.1 | ColumnaccessSwitchVturConfRINH | read-only | current | Set getting status of Vtur Power Down or Dying Gasp in VTUC as enabled or disabled. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.15.1.2 | ColumnaccessSwitchVturConfLink | read-only | current | Set getting status of remote LAN link function as enabled or disabled. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.16 | TableaccessSwitchVturStateTable | not-accessible | current | Port remote state table |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.16.1 | RowaccessSwitchVturStateEntry | not-accessible | current | Port remote state entry - node for the status information of the remote equipment |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.16.1.1 | ColumnaccessSwitchVturStateRINH | read-only | current | Status of remote power down or Dying Gasp. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.16.1.2 | ColumnaccessSwitchVturStateLink | read-only | current | Status of remote LAN link. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.17 | TableaccessSwitchVturTrapConfTable | not-accessible | current | Port Trap configration table |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.17.1 | RowaccessSwitchVturTrapConfEntry | not-accessible | current | Port Trap configration entry - node for the configration of the remote Trap |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.17.1.1 | ColumnaccessSwitchVturTrapConfRINH | read-only | current | Enables and disables the Vtur Power Up/Down Trap. This object is defaulted disable(0). |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.17.1.2 | ColumnaccessSwitchVturTrapConfLink | read-only | current | Enables and disables the Vtur Link Trap. This object is defaulted disable(0). |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.18 | TableaccessSwitchVdslAlarmConfProfileTable | not-accessible | current | This table provides one row for each VTUR channel. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.18.1 | RowaccessSwitchVdslAlarmConfProfileEntry | not-accessible | current | An entry in the accessSwitchVdslAlarmConfProfile. |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.18.1.1 | ColumnaccessSwitchVdslLOSFailureTrapEnable | read-only | current | Enables and disables the LOSFailureTrap. This object is defaulted disable(1). |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.18.1.2 | ColumnaccessSwitchVdslOBErrorAlarmTrapEnable | read-only | current | Enables and disables the Over Bit Error alarm Trap. This object is defaulted disable(1). |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.18.1.3 | ColumnaccessSwitchVdslBminAlarmTrapEnable | read-only | current | Enables and disables the Bmin alarm Trap. This object is defaulted disable(1). |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.18.1.4 | ColumnaccessSwitchVdslLofAlarmTrapEnable | read-only | current | Enables and disables the Lof alarm Trap. This object is defaulted disable(1). |
| 1.3.6.1.4.1.890.1.5.12.1.1.1.18.1.5 | ColumnaccessSwitchVdslLprAlarmTrapEnable | read-only | current | Enables and disables the Lpr alarm Trap. This object is defaulted disable(1). |
| 1.3.6.1.4.1.890.1.5.12.1.1.2 | NodeaccessSwitchVdslLCSMib | |||
| 1.3.6.1.4.1.890.1.5.12.1.1.2.1 | NodeaccessSwitchVdslLCSMibObjects | |||
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2 | NodeaccessSwitchVdslLCSQam | |||
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.1 | TableaccessSwitchVdslVtuoQamTable | not-accessible | mandatory | This table provides one row for each VTU-O if QAM is used. Each row contains the modulation parameters for that VTU-O. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.1.1 | RowaccessSwitchVdslVtuoQamEntry | not-accessible | mandatory | An entry in the accessSwitchVdslVtuoQamTable. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.1.1.1 | ColumnaccessSwitchVdslVtuoQamConstellation | read-only | mandatory | Modulation method used by this VTU. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.1.1.2 | ColumnaccessSwitchVdslVtuoQamInterpolation | read-only | mandatory | Modulation speed used by this VTU. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.1.1.3 | ColumnaccessSwitchVdslVtuoQamFc | read-only | mandatory | Carrier frequency in Hz used by this ATU. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.2 | TableaccessSwitchVdslVturQamTable | not-accessible | mandatory | This table provides one row for each VTU-R if QAM is used. Each row contains the modulation parameters for that VTU-R. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.2.1 | RowaccessSwitchVdslVturQamEntry | not-accessible | mandatory | An entry in the accessSwitchVdslVturQamTable. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.2.1.1 | ColumnaccessSwitchVdslVturQamConstellation | read-only | mandatory | Modulation method used by this VTU. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.2.1.2 | ColumnaccessSwitchVdslVturQamInterpolation | read-only | mandatory | Modulation speed used by this VTU. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.2.1.3 | ColumnaccessSwitchVdslVturQamFc | read-only | mandatory | Carrier frequency in Hz used by this ATU. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.3 | TableaccessSwitchVdslVtuoPhySCMTable | not-accessible | current | This table provides one row for each VTUC. Each row contains the Physical Layer Parameters table for that VTUC. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.3.1 | RowaccessSwitchVdslVtuoPhySCMEntry | not-accessible | current | An entry in the accessSwitchVdslVtuoPhySCMTable. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.3.1.1 | ColumnaccessSwitchVdslVtuoSCMCurrLinkState | read-only | current | Show current state of the VTUC line. idle(0) - this VDSL line is not used. standby(1) - this VDSL line links down. show_time(2) - this VDSL line links up. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.3.1.2 | ColumnaccessSwitchVdslVtuoSCMCurrCenterFreq1 | read-only | current | Show current center frequency of downstream 1. This value is in units of Hz. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.3.1.3 | ColumnaccessSwitchVdslVtuoSCMCurrCenterFreq2 | read-only | current | Show current center frequency of downstream 2. This value is in units of Hz. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.3.1.4 | ColumnaccessSwitchVdslVtuoSCMCurrSymbolRate1 | read-only | current | Show current symbol rate of downstream 1. This value is in units of baud per second. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.3.1.5 | ColumnaccessSwitchVdslVtuoSCMCurrSymbolRate2 | read-only | current | Show current symbol rate of downstream 2. This value is in units of baud per second. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.3.1.6 | ColumnaccessSwitchVdslVtuoSCMCurrConstellation1 | read-only | current | Show current constellation of downstream 1. This value should be the power of 2. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.3.1.7 | ColumnaccessSwitchVdslVtuoSCMCurrConstellation2 | read-only | current | Show current constellation of downstream 2. This value should be the power of 2. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.3.1.8 | ColumnaccessSwitchVdslVtuoSCMCurrPSDLevel1 | read-only | current | Show the current transmit PSD level of downstream 1. This value is in units of 0.5 dBm/Hz. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.3.1.9 | ColumnaccessSwitchVdslVtuoSCMCurrPSDLevel2 | read-only | current | Show the current transmit PSD level of downstream 2. This value is in units of 0.5 dBm/Hz. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.3.1.10 | ColumnaccessSwitchVdslVtuoSCMCurrSnr1 | read-only | current | Show the current SNR value of upstream 1. This value is in units of 0.5 dB. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.3.1.11 | ColumnaccessSwitchVdslVtuoSCMCurrSnr2 | read-only | current | Show the current SNR value of upstream 2. This value is in units of 0.5 dB. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.3.1.12 | ColumnaccessSwitchVdslVtuoSCMCurrSnrMgn1 | read-only | current | Show the current SNR margin of upstream 1. This value is in units of 0.5 dB. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.3.1.13 | ColumnaccessSwitchVdslVtuoSCMCurrSnrMgn2 | read-only | current | Show the current SNR margin of upstream 2. This value is in units of 0.5 dB. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.3.1.14 | ColumnaccessSwitchVdslVtuoSCMCurrTxPower1 | read-only | current | Show the current transmit power of downstream 1. This value is in units of 0.5 dBm. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.3.1.15 | ColumnaccessSwitchVdslVtuoSCMCurrTxPower2 | read-only | current | Show the current transmit power of downstream 2. This value is in units of 0.5 dBm. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.3.1.16 | ColumnaccessSwitchVdslVtuoSCMCurrAttenuation1 | read-only | current | Show the current transmit power of upstream 1. This value is in units of 0.5 dB. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.3.1.17 | ColumnaccessSwitchVdslVtuoSCMCurrAttenuation2 | read-only | current | Show the current transmit power of upstream 2. This value is in units of 0.5 dB. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.3.1.18 | ColumnaccessSwitchVdslVtuoSCMCurrInterleaveDelay | read-only | current | Show the current interleave delay of downstream. This value is in units of 0.5 ms. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.3.1.19 | ColumnaccessSwitchVdslVtuoSCMCurrStatus | read-only | current | Indicates current status of the upstream. This is a bit-map of possible conditions. The various bit positions are: 0 noDefect There is no defect on the line. 1… |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.4 | TableaccessSwitchVdslVturPhySCMTable | not-accessible | current | This table provides one row for each VTUR. Each row contains the Physical Layer Parameters table for that VTUR. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.4.1 | RowaccessSwitchVdslVturPhySCMEntry | not-accessible | current | An entry in the accessSwitchVdslVturPhySCMTable. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.4.1.1 | ColumnaccessSwitchVdslVturSCMCurrLinkState | read-only | current | Show current state of the VTUR line. idle(0) - this VDSL line is not used. standby(1) - this VDSL line links down. show_time(2) - this VDSL line links up. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.4.1.2 | ColumnaccessSwitchVdslVturSCMCurrCenterFreq1 | read-only | current | Show current center frequency of upstream 1. This value is in units of Hz. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.4.1.3 | ColumnaccessSwitchVdslVturSCMCurrCenterFreq2 | read-only | current | Show current center frequency of upstream 2. This value is in units of Hz. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.4.1.4 | ColumnaccessSwitchVdslVturSCMCurrSymbolRate1 | read-only | current | Show current symbol rate of upstream 1. This value is in units of baud per second. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.4.1.5 | ColumnaccessSwitchVdslVturSCMCurrSymbolRate2 | read-only | current | Show current symbol rate of upstream 2. This value is in units of baud per second. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.4.1.6 | ColumnaccessSwitchVdslVturSCMCurrConstellation1 | read-only | current | Show current constellation of upstream 1. This value should be the power of 2. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.4.1.7 | ColumnaccessSwitchVdslVturSCMCurrConstellation2 | read-only | current | Show current constellation of upstream 2. This value should be the power of 2. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.4.1.8 | ColumnaccessSwitchVdslVturSCMCurrPSDLevel1 | read-only | current | Show the current transmit PSD level of upstream 1. This value is in units of 0.5 dBm/Hz. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.4.1.9 | ColumnaccessSwitchVdslVturSCMCurrPSDLevel2 | read-only | current | Show the current transmit PSD level of upstream 2. This value is in units of 0.5 dBm/Hz. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.4.1.10 | ColumnaccessSwitchVdslVturSCMCurrSnr1 | read-only | current | Show the current SNR value of downstream 1. This value is in units of 0.5 dB. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.4.1.11 | ColumnaccessSwitchVdslVturSCMCurrSnr2 | read-only | current | Show the current SNR value of downstream 2. This value is in units of 0.5 dB. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.4.1.12 | ColumnaccessSwitchVdslVturSCMCurrSnrMgn1 | read-only | current | Show the current SNR margin of downstream 1. This value is in units of 0.5 dB. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.4.1.13 | ColumnaccessSwitchVdslVturSCMCurrSnrMgn2 | read-only | current | Show the current SNR margin of downstream 2. This value is in units of 0.5 dB. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.4.1.14 | ColumnaccessSwitchVdslVturSCMCurrTxPower1 | read-only | current | Show the current transmit power of upstream 1. This value is in units of 0.5 dBm. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.4.1.15 | ColumnaccessSwitchVdslVturSCMCurrTxPower2 | read-only | current | Show the current transmit power of upstream 2. This value is in units of 0.5 dBm. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.4.1.16 | ColumnaccessSwitchVdslVturSCMCurrAttenuation1 | read-only | current | Show the current transmit power of downstream 1. This value is in units of 0.5 dB. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.4.1.17 | ColumnaccessSwitchVdslVturSCMCurrAttenuation2 | read-only | current | Show the current transmit power of downstream 2. This value is in units of 0.5 dB. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.4.1.18 | ColumnaccessSwitchVdslVturSCMCurrInterleaveDelay | read-only | current | Show the current interleave delay of upstream. This value is in units of 0.5 ms. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.2.4.1.19 | ColumnaccessSwitchVdslVturSCMCurrStatus | read-only | current | Indicates current status of the downstream. This is a bit-map of possible conditions. The various bit positions are: 0 noDefect There is no defect on the line.… |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.3 | NodeaccessSwitchVdslLCSDMT | |||
| 1.3.6.1.4.1.890.1.5.12.1.1.2.3.1 | TableaccessSwitchVdslVtuoPhyMCMTable | not-accessible | current | This table provides one row for each VTUC. Each row contains the Physical Layer Parameters table for that VTUC. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.3.1.1 | RowaccessSwitchVdslVtuoPhyMCMEntry | not-accessible | current | An entry in the accessSwitchVdslVtuoPhyMCMTable. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.3.1.1.1 | ColumnaccessSwitchVdslVtuoMCMCurrLinkState | read-only | current | Show current state of the VTUC line. idle(0) - this VDSL line is not used. standby(1) - this VDSL line links down. show_time(2) - this VDSL line links up. trai… |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.3.1.1.2 | ColumnaccessSwitchVdslVtuoMCMCurrSnrMgn | read-only | current | Show the current SNR margin of upstream 1. This value is in units of 0.1 dB. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.3.1.1.3 | ColumnaccessSwitchVdslVtuoMCMCurrTxPower | read-only | current | Show the current transmit power of downstream 1. This value is in units of 0.1 dBm. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.3.1.1.4 | ColumnaccessSwitchVdslVtuoMCMCurrAttenuation | read-only | current | Show the current transmit power of upstream 1. This value is in units of 0.1 dB. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.3.1.1.5 | ColumnaccessSwitchVdslVtuoMCMCurrInterleaveDelay | read-only | current | Show the current interleave delay of downstream. This value is in units of 0.5 ms. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.3.1.1.6 | ColumnaccessSwitchVdslVtuoMCMCurrStatus | read-only | current | Indicates current status of the upstream. This is a bit-map of possible conditions. The various bit positions are: 0 noDefect There is no defect on the line. 1… |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.3.2 | TableaccessSwitchVdslVturPhyMCMTable | not-accessible | current | This table provides one row for each VTUR. Each row contains the Physical Layer Parameters table for that VTUR. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.3.2.1 | RowaccessSwitchVdslVturPhyMCMEntry | not-accessible | current | An entry in the accessSwitchVdslVturPhyMCMTable. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.3.2.1.1 | ColumnaccessSwitchVdslVturMCMCurrLinkState | read-only | current | Show current state of the VTUR line. idle(0) - this VDSL line is not used. standby(1) - this VDSL line links down. show_time(2) - this VDSL line links up. trai… |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.3.2.1.2 | ColumnaccessSwitchVdslVturMCMCurrSnrMgn | read-only | current | Show the current SNR margin of downstream 1. This value is in units of 0.5 dB. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.3.2.1.3 | ColumnaccessSwitchVdslVturMCMCurrTxPower | read-only | current | Show the current transmit power of upstream 1. This value is in units of 0.5 dBm. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.3.2.1.4 | ColumnaccessSwitchVdslVturMCMCurrAttenuation | read-only | current | Show the current transmit power of downstream 1. This value is in units of 0.1 dB. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.3.2.1.5 | ColumnaccessSwitchVdslVturMCMCurrInterleaveDelay | read-only | current | Show the current interleave delay of upstream. This value is in units of 0.5 ms. |
| 1.3.6.1.4.1.890.1.5.12.1.1.2.3.2.1.6 | ColumnaccessSwitchVdslVturMCMCurrStatus | read-only | current | Indicates current status of the downstream. This is a bit-map of possible conditions. The various bit positions are: 0 noDefect There is no defect on the line.… |