MIB Viewer

ZYXELVDSL

263 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.890.1.5.12.1.1NodeaccessSwitchVdslLineMib
1.3.6.1.4.1.890.1.5.12.1.1.1NodeaccessSwitchVdslLineMibObjects
1.3.6.1.4.1.890.1.5.12.1.1.1.1TableaccessSwitchVdslLineTablenot-accessiblemandatoryThis table includes common attributes describing both ends of the line.
1.3.6.1.4.1.890.1.5.12.1.1.1.1.1RowaccessSwitchVdslLineEntrynot-accessiblemandatoryAn entry in the accessSwitchVdslLineTable.
1.3.6.1.4.1.890.1.5.12.1.1.1.1.1.1ColumnaccessSwitchVdslLineCodingread-onlymandatorySpecifies the VDSL coding type used on this line.
1.3.6.1.4.1.890.1.5.12.1.1.1.1.1.2ColumnaccessSwitchVdslLineDiscCountread-onlymandatoryCount of the number of disconnection failures since agent reset.
1.3.6.1.4.1.890.1.5.12.1.1.1.1.1.3ColumnaccessSwitchVdslLineConfProfileread-onlymandatoryThe value of this object identifies the row in the VDSL Line Configuration Profile Table, (accessSwitchVdslLineConfProfileTable), which applies for this VDSL l…
1.3.6.1.4.1.890.1.5.12.1.1.1.1.1.4ColumnaccessSwitchVdslLineTyperead-onlycurrentDefines the type of VDSL physical line entity that exists, by defining whether and how the line is channelized. If the line is channelized, the value will be o…
1.3.6.1.4.1.890.1.5.12.1.1.1.2TableaccessSwitchVdslVtuoPhysTablenot-accessiblemandatoryThis table provides one row for each VTU-O. Each row contains the physical layer parameters for that VTU-O.
1.3.6.1.4.1.890.1.5.12.1.1.1.2.1RowaccessSwitchVdslVtuoPhysEntrynot-accessiblemandatoryAn entry in the accessSwitchVdslVtuoPhysTable.
1.3.6.1.4.1.890.1.5.12.1.1.1.2.1.1ColumnaccessSwitchVdslVtuoCurrSnrMgnread-onlymandatoryNoise Margin as seen by this VTU with respect to its received signal in 0.01dB.
1.3.6.1.4.1.890.1.5.12.1.1.1.2.1.2ColumnaccessSwitchVdslVtuoCurrMseread-onlymandatoryMinimum Square Error as seen by this VTU with respect to its received signal in 0.01dB.
1.3.6.1.4.1.890.1.5.12.1.1.1.2.1.3ColumnaccessSwitchVdslVtuoCurrPsdread-onlymandatoryPower Spectral Density as seen by this VTU with respect to its received signal in -0.01dBm/Hz.
1.3.6.1.4.1.890.1.5.12.1.1.1.2.1.4ColumnaccessSwitchVdslVtuoCurrRsErrread-onlymandatoryReed-Solomon error counted by this VTU with respect to its received signal.
1.3.6.1.4.1.890.1.5.12.1.1.1.2.1.5ColumnaccessSwitchVdslVtuoCurrAtnread-onlymandatoryMeasured difference in the total power transmitted by the peer VTU and the total power received by this VTU.
1.3.6.1.4.1.890.1.5.12.1.1.1.2.1.6ColumnaccessSwitchVdslVtuoCurrOutputPwrread-onlymandatoryMeasured total output power in 0.01dBm transmitted by this VTU.
1.3.6.1.4.1.890.1.5.12.1.1.1.2.1.7ColumnaccessSwitchVdslVtuoCurrRateread-onlymandatoryActual transmission rate in bits-per-second on this line.
1.3.6.1.4.1.890.1.5.12.1.1.1.2.1.8ColumnaccessSwitchVdslVtuoChanCurrLineRateread-onlycurrentActual transmit rate of downstream from VTUC. This value is in units of bps.
1.3.6.1.4.1.890.1.5.12.1.1.1.2.1.9ColumnaccessSwitchVdslVtuoCurrAttainableRateread-onlymandatoryIndicates the maximum mandatoryly attainable data rate in bits-per-second by the VTU. This value will be equal or greater than the mandatory line rate.
1.3.6.1.4.1.890.1.5.12.1.1.1.2.1.10ColumnaccessSwitchVdslVtuoCurrStatusread-onlymandatoryIndicates mandatory state of the VTU-O line. This is a bit-map of possible conditions. The various bit positions are: 0 noDefect There no defects on the line 1…
1.3.6.1.4.1.890.1.5.12.1.1.1.3TableaccessSwitchVdslVturPhysTablenot-accessiblemandatoryThis table provides one row for each VTU-R. Each row contains the physical layer parameters for that VTU-R.
1.3.6.1.4.1.890.1.5.12.1.1.1.3.1RowaccessSwitchVdslVturPhysEntrynot-accessiblemandatoryAn entry in the accessSwitchVdslVturPhysTable.
1.3.6.1.4.1.890.1.5.12.1.1.1.3.1.1ColumnaccessSwitchVdslVturCurrSnrMgnread-onlymandatoryNoise Margin as seen by this VTU with respect to its received signal in 0.01dB.
1.3.6.1.4.1.890.1.5.12.1.1.1.3.1.2ColumnaccessSwitchVdslVturCurrMseread-onlymandatoryMinimum Square Error as seen by this VTU with respect to its received signal in 0.01dB.
1.3.6.1.4.1.890.1.5.12.1.1.1.3.1.3ColumnaccessSwitchVdslVturCurrPsdread-onlymandatoryPower Spectral Density as seen by this VTU with respect to its received signal in -0.01dBm/Hz.
1.3.6.1.4.1.890.1.5.12.1.1.1.3.1.4ColumnaccessSwitchVdslVturCurrRsErrread-onlymandatoryReed-Solomon error counted by this VTU with respect to its received signal.
1.3.6.1.4.1.890.1.5.12.1.1.1.3.1.5ColumnaccessSwitchVdslVturCurrAtnread-onlymandatoryMeasured difference in the total power transmitted by the peer VTU and the total power received by this VTU.
1.3.6.1.4.1.890.1.5.12.1.1.1.3.1.6ColumnaccessSwitchVdslVturCurrOutputPwrread-onlymandatoryMeasured total output power in 0.01dBm transmitted by this VTU.
1.3.6.1.4.1.890.1.5.12.1.1.1.3.1.7ColumnaccessSwitchVdslVturCurrRateread-onlymandatoryActual transmission rate in bits-per-second on this line.
1.3.6.1.4.1.890.1.5.12.1.1.1.3.1.8ColumnaccessSwitchVdslVturChanCurrLineRateread-onlycurrentActual transmit rate of upstream from VTUR. This value is in units of bps.
1.3.6.1.4.1.890.1.5.12.1.1.1.3.1.9ColumnaccessSwitchVdslVturCurrAttainableRateread-onlymandatoryIndicates the maximum mandatoryly attainable data rate in bits-per-second by the VTU. This value will be equal or greater than the mandatory line rate.
1.3.6.1.4.1.890.1.5.12.1.1.1.3.1.10ColumnaccessSwitchVdslVturCurrStatusread-onlymandatoryIndicates mandatory state of the VTU-R line. This is a bit-map of possible conditions. The various bit positions are: 0 noDefect There no defects on the line 1…
1.3.6.1.4.1.890.1.5.12.1.1.1.4TableaccessSwitchVdslVtuoInventoryTablenot-accessiblemandatoryThis table provides one row for each VTU-O. Each row contains the inventory parameters for that VTU-O.
1.3.6.1.4.1.890.1.5.12.1.1.1.4.1RowaccessSwitchVdslVtuoInventoryEntrynot-accessiblemandatoryAn entry in the accessSwitchVdslVtuoInventoryTable.
1.3.6.1.4.1.890.1.5.12.1.1.1.4.1.1ColumnaccessSwitchVdslVtuoInvSerialNumberread-onlymandatoryThe vendor specific string that identifies the vendor equipment.
1.3.6.1.4.1.890.1.5.12.1.1.1.4.1.2ColumnaccessSwitchVdslVtuoInvVendorIDread-onlymandatoryThe vendor ID code is a copy of the binary vendor identification field defined by the PHY[10] and expressed as readable characters.
1.3.6.1.4.1.890.1.5.12.1.1.1.4.1.3ColumnaccessSwitchVdslVtuoInvVersionNumberread-onlymandatoryThe vendor specific version number sent by this VTU as part of the initialization messages. It is a copy of the binary version number field defined by the PHY[…
1.3.6.1.4.1.890.1.5.12.1.1.1.5TableaccessSwitchVdslVturInventoryTablenot-accessiblemandatoryThis table provides one row for each VTU-R. Each row contains the inventory parameters for that VTU-R.
1.3.6.1.4.1.890.1.5.12.1.1.1.5.1RowaccessSwitchVdslVturInventoryEntrynot-accessiblemandatoryAn entry in the accessSwitchVdslVturInventoryTable.
1.3.6.1.4.1.890.1.5.12.1.1.1.5.1.1ColumnaccessSwitchVdslVturInvSerialNumberread-onlymandatoryThe vendor specific string that identifies the vendor equipment.
1.3.6.1.4.1.890.1.5.12.1.1.1.5.1.2ColumnaccessSwitchVdslVturInvVendorIDread-onlymandatoryThe vendor ID code is a copy of the binary vendor identification field defined by the PHY[10] and expressed as readable characters.
1.3.6.1.4.1.890.1.5.12.1.1.1.5.1.3ColumnaccessSwitchVdslVturInvVersionNumberread-onlymandatoryThe vendor specific version number sent by this VTU as part of the initialization messages. It is a copy of the binary version number field defined by the PHY[…
1.3.6.1.4.1.890.1.5.12.1.1.1.6TableaccessSwitchVdslVtuoPerfDataTablenot-accessiblemandatoryThis table provides one row for each VTU-O.
1.3.6.1.4.1.890.1.5.12.1.1.1.6.1RowaccessSwitchVdslVtuoPerfDataEntrynot-accessiblemandatoryAn entry in accessSwitchVdslVtuoPerfDataTable.
1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.1ColumnaccessSwitchVdslVtuoPerfLofsread-onlymandatoryCount of the number of Loss of Framing failures since agent reset.
1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.2ColumnaccessSwitchVdslVtuoPerfLossread-onlymandatoryCount of the number of Loss of Signal failures since agent reset.
1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.3ColumnaccessSwitchVdslVtuoPerfLolsread-onlymandatoryCount of the number of Loss of Link failures since agent reset.
1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.4ColumnaccessSwitchVdslVtuoPerfLprsread-onlymandatoryCount of the number of Loss of Power failures since agent reset.
1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.5ColumnaccessSwitchVdslVtuoPerfESsread-onlymandatoryCount of the number of Errored Seconds since agent reset. The errored second parameter is a count of one-second intervals containing one or more crc anomalies,…
1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.6ColumnaccessSwitchVdslVtuoPerfInitsread-onlymandatoryCount of the line initialization attempts since agent reset. Includes both successful and failed attempts.
1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.7ColumnaccessSwitchVdslVtuoPerfValidIntervalsread-onlymandatoryThe number of previous 15-minute intervals in the interval table for which data was collected. Given that <n> is the maximum # of intervals supported. The valu…
1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.8ColumnaccessSwitchVdslVtuoPerfInvalidIntervalsread-onlymandatoryThe number of intervals in the range from 0 to the value of accessSwitchVdslVtuoPerfValidIntervals for which no data is available. This object will typically b…
1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.9ColumnaccessSwitchVdslVtuoPerfCurr15MinTimeElapsedread-onlymandatoryTotal elapsed seconds in this interval.
1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.10ColumnaccessSwitchVdslVtuoPerfCurr15MinLofsread-onlymandatoryCount of seconds in the mandatory 15 minute interval when there was Loss of Framing.
1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.11ColumnaccessSwitchVdslVtuoPerfCurr15MinLossread-onlymandatoryCount of seconds in the mandatory 15 minute interval when there was Loss of Signal.
1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.12ColumnaccessSwitchVdslVtuoPerfCurr15MinLolsread-onlymandatoryCount of seconds in the mandatory 15 minute interval when there was Loss of Link.
1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.13ColumnaccessSwitchVdslVtuoPerfCurr15MinLprsread-onlymandatoryCount of seconds in the mandatory 15 minute interval when there was Loss of Power.
1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.14ColumnaccessSwitchVdslVtuoPerfCurr15MinESsread-onlymandatoryCount of Errored Seconds in the mandatory 15 minute interval. The errored second parameter is a count of one-second intervals containing one or more crc anomal…
1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.15ColumnaccessSwitchVdslVtuoPerfCurr15MinInitsread-onlymandatoryCount of the line initialization attempts in the mandatory 15 minute interval. Includes both successful and failed attempts.
1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.16ColumnaccessSwitchVdslVtuoPerfCurr1DayTimeElapsedread-onlymandatoryNumber of seconds that have elapsed since the beginning of the mandatory 1-day interval.
1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.17ColumnaccessSwitchVdslVtuoPerfCurr1DayLofsread-onlymandatoryCount of the number of seconds when there was Loss of Framing during the mandatory day as measured by accessSwitchVdslVtuoPerfCurr1DayTimeElapsed.
1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.18ColumnaccessSwitchVdslVtuoPerfCurr1DayLossread-onlymandatoryCount of the number of seconds when there was Loss of Signal during the mandatory day as measured by accessSwitchVdslVtuoPerfCurr1DayTimeElapsed.
1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.19ColumnaccessSwitchVdslVtuoPerfCurr1DayLolsread-onlymandatoryCount of the number of seconds when there was Loss of Link during the mandatory day as measured by accessSwitchVdslVtuoPerfCurr1DayTimeElapsed.
1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.20ColumnaccessSwitchVdslVtuoPerfCurr1DayLprsread-onlymandatoryCount of the number of seconds when there was Loss of Power during the mandatory day as measured by accessSwitchVdslVtuoPerfCurr1DayTimeElapsed.
1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.21ColumnaccessSwitchVdslVtuoPerfCurr1DayESsread-onlymandatoryCount of Errored Seconds during the mandatory day as measured by accessSwitchVdslVtuoPerfCurr1DayTimeElapsed. The errored second parameter is a count of one-se…
1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.22ColumnaccessSwitchVdslVtuoPerfCurr1DayInitsread-onlymandatoryCount of the line initialization attempts in the day as measured by accessSwitchVdslVtuoPerfCurr1DayTimeElapsed. Includes both successful and failed attempts.
1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.23ColumnaccessSwitchVdslVtuoPerfPrev1DayMoniSecsread-onlymandatoryThe amount of time in the previous 1-day interval over which the performance monitoring information is actually counted. This value will be the same as the int…
1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.24ColumnaccessSwitchVdslVtuoPerfPrev1DayLofsread-onlymandatoryCount of seconds in the interval when there was Loss of Framing within the most recent previous 1-day period.
1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.25ColumnaccessSwitchVdslVtuoPerfPrev1DayLossread-onlymandatoryCount of seconds in the interval when there was Loss of Signal within the most recent previous 1-day period.
1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.26ColumnaccessSwitchVdslVtuoPerfPrev1DayLolsread-onlymandatoryCount of seconds in the interval when there was Loss of Link within the most recent previous 1-day period.
1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.27ColumnaccessSwitchVdslVtuoPerfPrev1DayLprsread-onlymandatoryCount of seconds in the interval when there was Loss of Power within the most recent previous 1-day period.
1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.28ColumnaccessSwitchVdslVtuoPerfPrev1DayESsread-onlymandatoryCount of Errored Seconds within the most recent previous 1-day period. The errored second parameter is a count of one-second intervals containing one or more c…
1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.29ColumnaccessSwitchVdslVtuoPerfPrev1DayInitsread-onlymandatoryCount of the line initialization attempts in the most recent previous 1-day period. Includes both successful and failed attempts.
1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.30ColumnaccessSwitchVdslVtuoPerfBerrread-onlycurrentCount of the number of Over limited error sencond since agent reset.
1.3.6.1.4.1.890.1.5.12.1.1.1.6.1.31ColumnaccessSwitchVdslVtuoPerfBminread-onlycurrentCount of the number of Under Min Margin since agent reset.
1.3.6.1.4.1.890.1.5.12.1.1.1.7TableaccessSwitchVdslVturPerfDataTablenot-accessiblemandatoryThis table provides one row for each VTU-R.
1.3.6.1.4.1.890.1.5.12.1.1.1.7.1RowaccessSwitchVdslVturPerfDataEntrynot-accessiblemandatoryAn entry in accessSwitchVdslVturPerfDataTable.
1.3.6.1.4.1.890.1.5.12.1.1.1.7.1.1ColumnaccessSwitchVdslVturPerfLofsread-onlymandatoryCount of the number of Loss of Framing failures since agent reset.
1.3.6.1.4.1.890.1.5.12.1.1.1.7.1.2ColumnaccessSwitchVdslVturPerfLossread-onlymandatoryCount of the number of Loss of Signal failures since agent reset.
1.3.6.1.4.1.890.1.5.12.1.1.1.7.1.3ColumnaccessSwitchVdslVturPerfLprsread-onlymandatoryCount of the number of Loss of Power failures since agent reset.
1.3.6.1.4.1.890.1.5.12.1.1.1.7.1.4ColumnaccessSwitchVdslVturPerfESsread-onlymandatoryCount of the number of Errored Seconds since agent reset. The errored second parameter is a count of one-second intervals containing one or more crc anomalies,…
1.3.6.1.4.1.890.1.5.12.1.1.1.7.1.5ColumnaccessSwitchVdslVturPerfValidIntervalsread-onlymandatoryThe number of previous 15-minute intervals in the interval table for which data was collected. Given that <n> is the maximum # of intervals supported. The valu…
1.3.6.1.4.1.890.1.5.12.1.1.1.7.1.6ColumnaccessSwitchVdslVturPerfInvalidIntervalsread-onlymandatoryThe number of intervals in the range from 0 to the value of accessSwitchVdslVturPerfValidIntervals for which no data is available. This object will typically b…
1.3.6.1.4.1.890.1.5.12.1.1.1.7.1.7ColumnaccessSwitchVdslVturPerfCurr15MinTimeElapsedread-onlymandatoryTotal elapsed seconds in this interval.
1.3.6.1.4.1.890.1.5.12.1.1.1.7.1.8ColumnaccessSwitchVdslVturPerfCurr15MinLofsread-onlymandatoryCount of seconds in the mandatory 15 minute interval when there was Loss of Framing.
1.3.6.1.4.1.890.1.5.12.1.1.1.7.1.9ColumnaccessSwitchVdslVturPerfCurr15MinLossread-onlymandatoryCount of seconds in the mandatory 15 minute interval when there was Loss of Signal.
1.3.6.1.4.1.890.1.5.12.1.1.1.7.1.10ColumnaccessSwitchVdslVturPerfCurr15MinLprsread-onlymandatoryCount of seconds in the mandatory 15 minute interval when there was Loss of Power.
1.3.6.1.4.1.890.1.5.12.1.1.1.7.1.11ColumnaccessSwitchVdslVturPerfCurr15MinESsread-onlymandatoryCount of Errored Seconds in the mandatory 15 minute interval. The errored second parameter is a count of one-second intervals containing one or more crc anomal…
1.3.6.1.4.1.890.1.5.12.1.1.1.7.1.12ColumnaccessSwitchVdslVturPerfCurr1DayTimeElapsedread-onlymandatoryNumber of seconds that have elapsed since the beginning of the mandatory 1-day interval.
1.3.6.1.4.1.890.1.5.12.1.1.1.7.1.13ColumnaccessSwitchVdslVturPerfCurr1DayLofsread-onlymandatoryCount of the number of seconds when there was Loss of Framing during the mandatory day as measured by accessSwitchVdslVturPerfCurr1DayTimeElapsed.
1.3.6.1.4.1.890.1.5.12.1.1.1.7.1.14ColumnaccessSwitchVdslVturPerfCurr1DayLossread-onlymandatoryCount of the number of seconds when there was Loss of Signal during the mandatory day as measured by accessSwitchVdslVturPerfCurr1DayTimeElapsed.
1.3.6.1.4.1.890.1.5.12.1.1.1.7.1.15ColumnaccessSwitchVdslVturPerfCurr1DayLprsread-onlymandatoryCount of the number of seconds when there was Loss of Power during the mandatory day as measured by accessSwitchVdslVturPerfCurr1DayTimeElapsed.
1.3.6.1.4.1.890.1.5.12.1.1.1.7.1.16ColumnaccessSwitchVdslVturPerfCurr1DayESsread-onlymandatoryCount of Errored Seconds during the mandatory day as measured by accessSwitchVdslVturPerfCurr1DayTimeElapsed. The errored second parameter is a count of one-se…
1.3.6.1.4.1.890.1.5.12.1.1.1.7.1.17ColumnaccessSwitchVdslVturPerfPrev1DayMoniSecsread-onlymandatoryThe amount of time in the previous 1-day interval over which the performance monitoring information is actually counted. This value will be the same as the int…
1.3.6.1.4.1.890.1.5.12.1.1.1.7.1.18ColumnaccessSwitchVdslVturPerfPrev1DayLofsread-onlymandatoryCount of seconds in the interval when there was Loss of Framing within the most recent previous 1-day period.
1.3.6.1.4.1.890.1.5.12.1.1.1.7.1.19ColumnaccessSwitchVdslVturPerfPrev1DayLossread-onlymandatoryCount of seconds in the interval when there was Loss of Signal within the most recent previous 1-day period.
1.3.6.1.4.1.890.1.5.12.1.1.1.7.1.20ColumnaccessSwitchVdslVturPerfPrev1DayLprsread-onlymandatoryCount of seconds in the interval when there was Loss of Power within the most recent previous 1-day period.
1.3.6.1.4.1.890.1.5.12.1.1.1.7.1.21ColumnaccessSwitchVdslVturPerfPrev1DayESsread-onlymandatoryCount of Errored Seconds within the most recent previous 1-day period. The errored second parameter is a count of one-second intervals containing one or more c…
1.3.6.1.4.1.890.1.5.12.1.1.1.7.1.22ColumnaccessSwitchVdslVturPerfBerrread-onlycurrentCount of the number of Over limited error seconds agent reset.
1.3.6.1.4.1.890.1.5.12.1.1.1.7.1.23ColumnaccessSwitchVdslVturPerfBminread-onlycurrentCount of the number of Under Min Margin since agent reset.
1.3.6.1.4.1.890.1.5.12.1.1.1.8TableaccessSwitchVdslVtuoIntervalTablenot-accessiblemandatoryThis table provides one row for each VTU-O performance data collection interval.
1.3.6.1.4.1.890.1.5.12.1.1.1.8.1RowaccessSwitchVdslVtuoIntervalEntrynot-accessiblemandatoryAn entry in the accessSwitchVdslVtuoIntervalTable.
1.3.6.1.4.1.890.1.5.12.1.1.1.8.1.1ColumnaccessSwitchVdslVtuoIntervalNumbernot-accessiblemandatoryPerformance Data Interval number 1 is the the most recent previous interval; interval 96 is 24 hours ago. Intervals 2..96 are optional.
1.3.6.1.4.1.890.1.5.12.1.1.1.8.1.2ColumnaccessSwitchVdslVtuoIntervalLofsread-onlymandatoryCount of seconds in the interval when there was Loss of Framing.
1.3.6.1.4.1.890.1.5.12.1.1.1.8.1.3ColumnaccessSwitchVdslVtuoIntervalLossread-onlymandatoryCount of seconds in the interval when there was Loss of Signal.
1.3.6.1.4.1.890.1.5.12.1.1.1.8.1.4ColumnaccessSwitchVdslVtuoIntervalLolsread-onlymandatoryCount of seconds in the interval when there was Loss of Link.
1.3.6.1.4.1.890.1.5.12.1.1.1.8.1.5ColumnaccessSwitchVdslVtuoIntervalLprsread-onlymandatoryCount of seconds in the interval when there was Loss of Power.
1.3.6.1.4.1.890.1.5.12.1.1.1.8.1.6ColumnaccessSwitchVdslVtuoIntervalESsread-onlymandatoryCount of Errored Seconds in the interval. The errored second parameter is a count of one-second intervals containing one or more crc anomalies, or one or more …
1.3.6.1.4.1.890.1.5.12.1.1.1.8.1.7ColumnaccessSwitchVdslVtuoIntervalInitsread-onlymandatoryCount of the line initialization attempts during the interval. Includes both successful and failed attempts.
1.3.6.1.4.1.890.1.5.12.1.1.1.8.1.8ColumnaccessSwitchVdslVtuoIntervalValidDataread-onlymandatoryThis variable indicates if the data for this interval is valid.
1.3.6.1.4.1.890.1.5.12.1.1.1.8.1.9ColumnaccessSwitchVdslVtucIntervalBerrread-onlycurrentNo of times in the interval when there was Over errored seconds.
1.3.6.1.4.1.890.1.5.12.1.1.1.8.1.10ColumnaccessSwitchVdslVtucIntervalBminread-onlycurrentNo of times in the interval when there was Under Min Margin.
1.3.6.1.4.1.890.1.5.12.1.1.1.9TableaccessSwitchVdslVturIntervalTablenot-accessiblemandatoryThis table provides one row for each VTU-R performance data collection interval.
1.3.6.1.4.1.890.1.5.12.1.1.1.9.1RowaccessSwitchVdslVturIntervalEntrynot-accessiblemandatoryAn entry in the accessSwitchVdslVturIntervalTable.
1.3.6.1.4.1.890.1.5.12.1.1.1.9.1.1ColumnaccessSwitchVdslVturIntervalNumbernot-accessiblemandatoryPerformance Data Interval number 1 is the the most recent previous interval; interval 96 is 24 hours ago. Intervals 2..96 are optional.
1.3.6.1.4.1.890.1.5.12.1.1.1.9.1.2ColumnaccessSwitchVdslVturIntervalLofsread-onlymandatoryCount of seconds in the interval when there was Loss of Framing.
1.3.6.1.4.1.890.1.5.12.1.1.1.9.1.3ColumnaccessSwitchVdslVturIntervalLossread-onlymandatoryCount of seconds in the interval when there was Loss of Signal.
1.3.6.1.4.1.890.1.5.12.1.1.1.9.1.4ColumnaccessSwitchVdslVturIntervalLprsread-onlymandatoryCount of seconds in the interval when there was Loss of Power.
1.3.6.1.4.1.890.1.5.12.1.1.1.9.1.5ColumnaccessSwitchVdslVturIntervalESsread-onlymandatoryCount of Errored Seconds in the interval. The errored second parameter is a count of one-second intervals containing one or more crc anomalies, or one or more …
1.3.6.1.4.1.890.1.5.12.1.1.1.9.1.6ColumnaccessSwitchVdslVturIntervalValidDataread-onlymandatoryThis variable indicates if the data for this interval is valid.
1.3.6.1.4.1.890.1.5.12.1.1.1.9.1.7ColumnaccessSwitchVdslVturIntervalBerrread-onlycurrentNo of times in the interval when there was Over limited error seconds.
1.3.6.1.4.1.890.1.5.12.1.1.1.9.1.8ColumnaccessSwitchVdslVturIntervalBminread-onlycurrentNo of times in the interval when there was Under Min Margin.
1.3.6.1.4.1.890.1.5.12.1.1.1.10TableaccessSwitchVdslLineConfProfileTablenot-accessiblemandatoryThis table contains information on the VDSL line configuration. One entry in this table reflects a profile which can be used to configure the VDSL line.
1.3.6.1.4.1.890.1.5.12.1.1.1.10.1RowaccessSwitchVdslLineConfProfileEntrynot-accessiblemandatoryEach entry consists of a list of parameters that represents the configuration of an VDSL modem. When `dynamic' profiles are implemented, a default profile will…
1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.1ColumnaccessSwitchVdslLineConfProfileNamenot-accessiblemandatoryThis object is used by the line configuration table in order to identify a row of this table. When `dynamic' profiles are implemented, the profile name is user…
1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.2ColumnaccessSwitchVdslLineConfModeread-onlymandatorySpecifies the VDSL mode type used on this line.
1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.3ColumnaccessSwitchVdslVtuoConfRateread-createmandatoryTransmission rate in bits-per-second specified by this VTU.
1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.4ColumnaccessSwitchVdslVtuoConfTargetSnrMgnread-onlymandatoryConfigured Target Signal/Noise Margin in 0.01dB. This is the Noise Margin the modem must achieve with a BER of 10-7 or better to successfully complete initiali…
1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.5ColumnaccessSwitchVdslVtuoConfMaxSnrMgnread-onlymandatoryConfigured Maximum acceptable Signal/Noise Margin in 0.01dB. If the Noise Margin is above this the modem should attempt to reduce its power output to optimize …
1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.6ColumnaccessSwitchVdslVtuoConfMinSnrMgnread-onlymandatoryConfigured Minimum acceptable Signal/Noise Margin in 0.01dB. If the noise margin falls below this level, the modem should attempt to increase its power output.…
1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.7ColumnaccessSwitchVdslVturConfRateread-onlymandatoryTransmission rate in bits-per-second specified by this VTU.
1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.8ColumnaccessSwitchVdslVturConfTargetSnrMgnread-onlymandatoryConfigured Target Signal/Noise Margin in 0.01dB. This is the Noise Margin the modem must achieve with a BER of 10-7 or better to successfully complete initiali…
1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.9ColumnaccessSwitchVdslVturConfMaxSnrMgnread-onlymandatoryConfigured Maximum acceptable Signal/Noise Margin in 0.01dB. If the Noise Margin is above this the modem should attempt to reduce its power output to optimize …
1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.10ColumnaccessSwitchVdslVturConfMinSnrMgnread-onlymandatoryConfigured Minimum acceptable Signal/Noise Margin in 0.01dB. If the noise margin falls below this level, the modem should attempt to increase its power output.…
1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.11ColumnaccessSwitchVdslLineConfProfileRowStatusread-createmandatoryThis object is used to create a new row or modify or delete an existing row in this table. A profile activated by setting this object to `active'. When `active…
1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.13ColumnaccessSwitchVdslConfRateAdaptiveModeread-writecurrentSet rate adptive mode as decrease mode or decrease & increase mode.
1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.14ColumnaccessSwitchVdslVtuoConfInterleaveMaxLineRateread-onlycurrentConfigured Maximum Transmit payload rate for `Interleave' channels, in bps.
1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.15ColumnaccessSwitchVdslVtuoConfInterleaveMinLineRateread-onlycurrentConfigured Minimum Transmit payload rate for `Interleave' channels, in bps.
1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.16ColumnaccessSwitchVdslVtuoConfMaxInterleaveDelayread-onlycurrentConfigured max. interleave delay of downstream. This value is in units of 0.5 ms.
1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.17ColumnaccessSwitchVdslVturConfInterleaveMaxLineRateread-onlycurrentConfigured Minimum Transmit payload rate for `Interleave' channels, in bps.
1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.18ColumnaccessSwitchVdslVturConfInterleaveMinLineRateread-onlycurrentConfigured Minimum Transmit payload rate for `Interleave' channels, in bps.
1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.19ColumnaccessSwitchVdslVturConfMaxInterleaveDelayread-onlycurrentConfigured max. interleave delay of downstream. This value is in units of 0.5 ms.
1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.20ColumnaccessSwitchVdslConfRFIread-onlycurrentSet RFI Band function as disabled, standard or custom.
1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.21ColumnaccessSwitchVdslRFIBand1Lowread-onlycurrentConfigured low of RFIBand1 function when custom RFI Band is used.
1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.22ColumnaccessSwitchVdslRFIBand1Highread-onlycurrentonfigured high of RFIBand1 function when custom RFI Band is used.
1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.23ColumnaccessSwitchVdslRFIBand2Lowread-onlycurrentConfigured low of RFIBand2 function when custom RFI Band is used.
1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.24ColumnaccessSwitchVdslRFIBand2Highread-onlycurrentConfigured high of RFIBand2 function when custom RFI Band is used.
1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.25ColumnaccessSwitchVdslRFIBand3Lowread-onlycurrentConfigured low of RFIBand3 function when custom RFI Band is used.
1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.26ColumnaccessSwitchVdslRFIBand3Highread-onlycurrentConfigured high of RFIBand3 function when custom RFI Band is used.
1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.27ColumnaccessSwitchVdslRFIBand4Lowread-onlycurrentConfigured low of RFIBand4 function when custom RFI Band is used.
1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.28ColumnaccessSwitchVdslRFIBand4Highread-onlycurrentConfigured high of RFIBand4 function when custom RFI Band is used.
1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.29ColumnaccessSwitchVdslConfCompatibleModeread-onlycurrentSet compatible mode to TCM-ISDN(0) or ADSL(1).
1.3.6.1.4.1.890.1.5.12.1.1.1.10.1.30ColumnaccessSwitchVdslPowerCutbackread-onlycurrentConfigured Power Cut Back. It is not supported in VES. Will be fixed at 0.
1.3.6.1.4.1.890.1.5.12.1.1.1.11ScalarvesMaxNumOfProfilesread-onlymandatoryThe maximum number of VDSL profiles which the system supports.
1.3.6.1.4.1.890.1.5.12.1.1.1.12TableaccessSwitchVdslVtucChanPerfDataTablenot-accessiblecurrentThis table provides one row for each VTUC channel.
1.3.6.1.4.1.890.1.5.12.1.1.1.12.1RowaccessSwitchVdslVtucChanPerfDataEntrynot-accessiblecurrentAn entry in the accessSwitchVdslVturPerfDataTable.
1.3.6.1.4.1.890.1.5.12.1.1.1.12.1.1ColumnaccessSwitchVdslVtucChanNumberread-onlycurrentChannel Number of VDSL.
1.3.6.1.4.1.890.1.5.12.1.1.1.12.1.2ColumnaccessSwitchVdslVtucChanRScorrectableBlksread-onlycurrentCount of all blocks received with errors that were RS correctable since agent reset. These blocks are passed on as good data.
1.3.6.1.4.1.890.1.5.12.1.1.1.12.1.3ColumnaccessSwitchvdslvtucChanCRCerrorBlksread-onlycurrentCount of all blocks received with CRC errors since agent reset.
1.3.6.1.4.1.890.1.5.12.1.1.1.13TableaccessSwitchVdslVturChanPerfDataTablenot-accessiblecurrentThis table provides one row for each VTUR channel.
1.3.6.1.4.1.890.1.5.12.1.1.1.13.1RowaccessSwitchVdslVturChanPerfDataEntrynot-accessiblecurrentAn entry in the accessSwitchVdslVturPerfDataTable.
1.3.6.1.4.1.890.1.5.12.1.1.1.13.1.1ColumnaccessSwitchVdslVturChanNumberread-onlycurrentChannel Number of VDSL.
1.3.6.1.4.1.890.1.5.12.1.1.1.13.1.2ColumnaccessSwitchVdslVturChanRScorrectableBlksread-onlycurrentCount of all blocks received with errors that were RS correctable since agent reset. These blocks are passed on as good data.
1.3.6.1.4.1.890.1.5.12.1.1.1.13.1.3ColumnaccessSwitchVdslVturChanCRCerrorBlksread-onlycurrentCount of all blocks received with CRC errors since agent reset.
1.3.6.1.4.1.890.1.5.12.1.1.1.14TableaccessSwitchVturDevTablenot-accessiblecurrentPort remote information table
1.3.6.1.4.1.890.1.5.12.1.1.1.14.1RowaccessSwitchVturDevEntrynot-accessiblecurrentPort remote information - node for the information of the remote equipment
1.3.6.1.4.1.890.1.5.12.1.1.1.14.1.1ColumnaccessSwitchVturDevNameread-onlycurrentThis object indicates the remote device name. Get by setting accessSwitchVturDevConfGet to (1)
1.3.6.1.4.1.890.1.5.12.1.1.1.14.1.2ColumnaccessSwitchVturDevVersionread-onlycurrentThis object indicates the remote device software version. Get by setting accessSwitchVturDevConfGet to (1)
1.3.6.1.4.1.890.1.5.12.1.1.1.14.1.3ColumnaccessSwitchVturDevIDread-onlycurrentThis object indicates the remote device ID. Get by setting accessSwitchVturDevConfGet to (1)
1.3.6.1.4.1.890.1.5.12.1.1.1.14.1.4ColumnaccessSwitchVturDevConfGetread-writecurrentSet to '1' to get name and version of remote equipment. Setting the object to '2' has no effect. This object always returns '2' when read.
1.3.6.1.4.1.890.1.5.12.1.1.1.14.1.5ColumnaccessSwitchVturResetread-onlycurrentSet to '1' to reset the remote equipment. Setting the object to '2' has no effect. This object always returns '2' when read.
1.3.6.1.4.1.890.1.5.12.1.1.1.14.1.6ColumnaccessSwitchVturResetVdslread-onlycurrentSet to '1' to reset the remote VDSL line. Setting the object to '2' has no effect. This object always returns '2' when read.
1.3.6.1.4.1.890.1.5.12.1.1.1.15TableaccessSwitchVturConfTablenot-accessiblecurrentport remote equipment information table
1.3.6.1.4.1.890.1.5.12.1.1.1.15.1RowaccessSwitchVturConfEntrynot-accessiblecurrentPort remote equipment entry - node for the equipment information of the remote
1.3.6.1.4.1.890.1.5.12.1.1.1.15.1.1ColumnaccessSwitchVturConfRINHread-onlycurrentSet getting status of Vtur Power Down or Dying Gasp in VTUC as enabled or disabled.
1.3.6.1.4.1.890.1.5.12.1.1.1.15.1.2ColumnaccessSwitchVturConfLinkread-onlycurrentSet getting status of remote LAN link function as enabled or disabled.
1.3.6.1.4.1.890.1.5.12.1.1.1.16TableaccessSwitchVturStateTablenot-accessiblecurrentPort remote state table
1.3.6.1.4.1.890.1.5.12.1.1.1.16.1RowaccessSwitchVturStateEntrynot-accessiblecurrentPort remote state entry - node for the status information of the remote equipment
1.3.6.1.4.1.890.1.5.12.1.1.1.16.1.1ColumnaccessSwitchVturStateRINHread-onlycurrentStatus of remote power down or Dying Gasp.
1.3.6.1.4.1.890.1.5.12.1.1.1.16.1.2ColumnaccessSwitchVturStateLinkread-onlycurrentStatus of remote LAN link.
1.3.6.1.4.1.890.1.5.12.1.1.1.17TableaccessSwitchVturTrapConfTablenot-accessiblecurrentPort Trap configration table
1.3.6.1.4.1.890.1.5.12.1.1.1.17.1RowaccessSwitchVturTrapConfEntrynot-accessiblecurrentPort Trap configration entry - node for the configration of the remote Trap
1.3.6.1.4.1.890.1.5.12.1.1.1.17.1.1ColumnaccessSwitchVturTrapConfRINHread-onlycurrentEnables and disables the Vtur Power Up/Down Trap. This object is defaulted disable(0).
1.3.6.1.4.1.890.1.5.12.1.1.1.17.1.2ColumnaccessSwitchVturTrapConfLinkread-onlycurrentEnables and disables the Vtur Link Trap. This object is defaulted disable(0).
1.3.6.1.4.1.890.1.5.12.1.1.1.18TableaccessSwitchVdslAlarmConfProfileTablenot-accessiblecurrentThis table provides one row for each VTUR channel.
1.3.6.1.4.1.890.1.5.12.1.1.1.18.1RowaccessSwitchVdslAlarmConfProfileEntrynot-accessiblecurrentAn entry in the accessSwitchVdslAlarmConfProfile.
1.3.6.1.4.1.890.1.5.12.1.1.1.18.1.1ColumnaccessSwitchVdslLOSFailureTrapEnableread-onlycurrentEnables and disables the LOSFailureTrap. This object is defaulted disable(1).
1.3.6.1.4.1.890.1.5.12.1.1.1.18.1.2ColumnaccessSwitchVdslOBErrorAlarmTrapEnableread-onlycurrentEnables and disables the Over Bit Error alarm Trap. This object is defaulted disable(1).
1.3.6.1.4.1.890.1.5.12.1.1.1.18.1.3ColumnaccessSwitchVdslBminAlarmTrapEnableread-onlycurrentEnables and disables the Bmin alarm Trap. This object is defaulted disable(1).
1.3.6.1.4.1.890.1.5.12.1.1.1.18.1.4ColumnaccessSwitchVdslLofAlarmTrapEnableread-onlycurrentEnables and disables the Lof alarm Trap. This object is defaulted disable(1).
1.3.6.1.4.1.890.1.5.12.1.1.1.18.1.5ColumnaccessSwitchVdslLprAlarmTrapEnableread-onlycurrentEnables and disables the Lpr alarm Trap. This object is defaulted disable(1).
1.3.6.1.4.1.890.1.5.12.1.1.2NodeaccessSwitchVdslLCSMib
1.3.6.1.4.1.890.1.5.12.1.1.2.1NodeaccessSwitchVdslLCSMibObjects
1.3.6.1.4.1.890.1.5.12.1.1.2.2NodeaccessSwitchVdslLCSQam
1.3.6.1.4.1.890.1.5.12.1.1.2.2.1TableaccessSwitchVdslVtuoQamTablenot-accessiblemandatoryThis table provides one row for each VTU-O if QAM is used. Each row contains the modulation parameters for that VTU-O.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.1.1RowaccessSwitchVdslVtuoQamEntrynot-accessiblemandatoryAn entry in the accessSwitchVdslVtuoQamTable.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.1.1.1ColumnaccessSwitchVdslVtuoQamConstellationread-onlymandatoryModulation method used by this VTU.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.1.1.2ColumnaccessSwitchVdslVtuoQamInterpolationread-onlymandatoryModulation speed used by this VTU.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.1.1.3ColumnaccessSwitchVdslVtuoQamFcread-onlymandatoryCarrier frequency in Hz used by this ATU.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.2TableaccessSwitchVdslVturQamTablenot-accessiblemandatoryThis table provides one row for each VTU-R if QAM is used. Each row contains the modulation parameters for that VTU-R.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.2.1RowaccessSwitchVdslVturQamEntrynot-accessiblemandatoryAn entry in the accessSwitchVdslVturQamTable.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.2.1.1ColumnaccessSwitchVdslVturQamConstellationread-onlymandatoryModulation method used by this VTU.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.2.1.2ColumnaccessSwitchVdslVturQamInterpolationread-onlymandatoryModulation speed used by this VTU.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.2.1.3ColumnaccessSwitchVdslVturQamFcread-onlymandatoryCarrier frequency in Hz used by this ATU.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.3TableaccessSwitchVdslVtuoPhySCMTablenot-accessiblecurrentThis table provides one row for each VTUC. Each row contains the Physical Layer Parameters table for that VTUC.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.3.1RowaccessSwitchVdslVtuoPhySCMEntrynot-accessiblecurrentAn entry in the accessSwitchVdslVtuoPhySCMTable.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.3.1.1ColumnaccessSwitchVdslVtuoSCMCurrLinkStateread-onlycurrentShow current state of the VTUC line. idle(0) - this VDSL line is not used. standby(1) - this VDSL line links down. show_time(2) - this VDSL line links up.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.3.1.2ColumnaccessSwitchVdslVtuoSCMCurrCenterFreq1read-onlycurrentShow current center frequency of downstream 1. This value is in units of Hz.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.3.1.3ColumnaccessSwitchVdslVtuoSCMCurrCenterFreq2read-onlycurrentShow current center frequency of downstream 2. This value is in units of Hz.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.3.1.4ColumnaccessSwitchVdslVtuoSCMCurrSymbolRate1read-onlycurrentShow current symbol rate of downstream 1. This value is in units of baud per second.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.3.1.5ColumnaccessSwitchVdslVtuoSCMCurrSymbolRate2read-onlycurrentShow current symbol rate of downstream 2. This value is in units of baud per second.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.3.1.6ColumnaccessSwitchVdslVtuoSCMCurrConstellation1read-onlycurrentShow current constellation of downstream 1. This value should be the power of 2.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.3.1.7ColumnaccessSwitchVdslVtuoSCMCurrConstellation2read-onlycurrentShow current constellation of downstream 2. This value should be the power of 2.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.3.1.8ColumnaccessSwitchVdslVtuoSCMCurrPSDLevel1read-onlycurrentShow the current transmit PSD level of downstream 1. This value is in units of 0.5 dBm/Hz.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.3.1.9ColumnaccessSwitchVdslVtuoSCMCurrPSDLevel2read-onlycurrentShow the current transmit PSD level of downstream 2. This value is in units of 0.5 dBm/Hz.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.3.1.10ColumnaccessSwitchVdslVtuoSCMCurrSnr1read-onlycurrentShow the current SNR value of upstream 1. This value is in units of 0.5 dB.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.3.1.11ColumnaccessSwitchVdslVtuoSCMCurrSnr2read-onlycurrentShow the current SNR value of upstream 2. This value is in units of 0.5 dB.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.3.1.12ColumnaccessSwitchVdslVtuoSCMCurrSnrMgn1read-onlycurrentShow the current SNR margin of upstream 1. This value is in units of 0.5 dB.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.3.1.13ColumnaccessSwitchVdslVtuoSCMCurrSnrMgn2read-onlycurrentShow the current SNR margin of upstream 2. This value is in units of 0.5 dB.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.3.1.14ColumnaccessSwitchVdslVtuoSCMCurrTxPower1read-onlycurrentShow the current transmit power of downstream 1. This value is in units of 0.5 dBm.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.3.1.15ColumnaccessSwitchVdslVtuoSCMCurrTxPower2read-onlycurrentShow the current transmit power of downstream 2. This value is in units of 0.5 dBm.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.3.1.16ColumnaccessSwitchVdslVtuoSCMCurrAttenuation1read-onlycurrentShow the current transmit power of upstream 1. This value is in units of 0.5 dB.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.3.1.17ColumnaccessSwitchVdslVtuoSCMCurrAttenuation2read-onlycurrentShow the current transmit power of upstream 2. This value is in units of 0.5 dB.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.3.1.18ColumnaccessSwitchVdslVtuoSCMCurrInterleaveDelayread-onlycurrentShow the current interleave delay of downstream. This value is in units of 0.5 ms.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.3.1.19ColumnaccessSwitchVdslVtuoSCMCurrStatusread-onlycurrentIndicates current status of the upstream. This is a bit-map of possible conditions. The various bit positions are: 0 noDefect There is no defect on the line. 1…
1.3.6.1.4.1.890.1.5.12.1.1.2.2.4TableaccessSwitchVdslVturPhySCMTablenot-accessiblecurrentThis table provides one row for each VTUR. Each row contains the Physical Layer Parameters table for that VTUR.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.4.1RowaccessSwitchVdslVturPhySCMEntrynot-accessiblecurrentAn entry in the accessSwitchVdslVturPhySCMTable.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.4.1.1ColumnaccessSwitchVdslVturSCMCurrLinkStateread-onlycurrentShow current state of the VTUR line. idle(0) - this VDSL line is not used. standby(1) - this VDSL line links down. show_time(2) - this VDSL line links up.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.4.1.2ColumnaccessSwitchVdslVturSCMCurrCenterFreq1read-onlycurrentShow current center frequency of upstream 1. This value is in units of Hz.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.4.1.3ColumnaccessSwitchVdslVturSCMCurrCenterFreq2read-onlycurrentShow current center frequency of upstream 2. This value is in units of Hz.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.4.1.4ColumnaccessSwitchVdslVturSCMCurrSymbolRate1read-onlycurrentShow current symbol rate of upstream 1. This value is in units of baud per second.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.4.1.5ColumnaccessSwitchVdslVturSCMCurrSymbolRate2read-onlycurrentShow current symbol rate of upstream 2. This value is in units of baud per second.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.4.1.6ColumnaccessSwitchVdslVturSCMCurrConstellation1read-onlycurrentShow current constellation of upstream 1. This value should be the power of 2.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.4.1.7ColumnaccessSwitchVdslVturSCMCurrConstellation2read-onlycurrentShow current constellation of upstream 2. This value should be the power of 2.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.4.1.8ColumnaccessSwitchVdslVturSCMCurrPSDLevel1read-onlycurrentShow the current transmit PSD level of upstream 1. This value is in units of 0.5 dBm/Hz.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.4.1.9ColumnaccessSwitchVdslVturSCMCurrPSDLevel2read-onlycurrentShow the current transmit PSD level of upstream 2. This value is in units of 0.5 dBm/Hz.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.4.1.10ColumnaccessSwitchVdslVturSCMCurrSnr1read-onlycurrentShow the current SNR value of downstream 1. This value is in units of 0.5 dB.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.4.1.11ColumnaccessSwitchVdslVturSCMCurrSnr2read-onlycurrentShow the current SNR value of downstream 2. This value is in units of 0.5 dB.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.4.1.12ColumnaccessSwitchVdslVturSCMCurrSnrMgn1read-onlycurrentShow the current SNR margin of downstream 1. This value is in units of 0.5 dB.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.4.1.13ColumnaccessSwitchVdslVturSCMCurrSnrMgn2read-onlycurrentShow the current SNR margin of downstream 2. This value is in units of 0.5 dB.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.4.1.14ColumnaccessSwitchVdslVturSCMCurrTxPower1read-onlycurrentShow the current transmit power of upstream 1. This value is in units of 0.5 dBm.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.4.1.15ColumnaccessSwitchVdslVturSCMCurrTxPower2read-onlycurrentShow the current transmit power of upstream 2. This value is in units of 0.5 dBm.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.4.1.16ColumnaccessSwitchVdslVturSCMCurrAttenuation1read-onlycurrentShow the current transmit power of downstream 1. This value is in units of 0.5 dB.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.4.1.17ColumnaccessSwitchVdslVturSCMCurrAttenuation2read-onlycurrentShow the current transmit power of downstream 2. This value is in units of 0.5 dB.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.4.1.18ColumnaccessSwitchVdslVturSCMCurrInterleaveDelayread-onlycurrentShow the current interleave delay of upstream. This value is in units of 0.5 ms.
1.3.6.1.4.1.890.1.5.12.1.1.2.2.4.1.19ColumnaccessSwitchVdslVturSCMCurrStatusread-onlycurrentIndicates current status of the downstream. This is a bit-map of possible conditions. The various bit positions are: 0 noDefect There is no defect on the line.…
1.3.6.1.4.1.890.1.5.12.1.1.2.3NodeaccessSwitchVdslLCSDMT
1.3.6.1.4.1.890.1.5.12.1.1.2.3.1TableaccessSwitchVdslVtuoPhyMCMTablenot-accessiblecurrentThis table provides one row for each VTUC. Each row contains the Physical Layer Parameters table for that VTUC.
1.3.6.1.4.1.890.1.5.12.1.1.2.3.1.1RowaccessSwitchVdslVtuoPhyMCMEntrynot-accessiblecurrentAn entry in the accessSwitchVdslVtuoPhyMCMTable.
1.3.6.1.4.1.890.1.5.12.1.1.2.3.1.1.1ColumnaccessSwitchVdslVtuoMCMCurrLinkStateread-onlycurrentShow current state of the VTUC line. idle(0) - this VDSL line is not used. standby(1) - this VDSL line links down. show_time(2) - this VDSL line links up. trai…
1.3.6.1.4.1.890.1.5.12.1.1.2.3.1.1.2ColumnaccessSwitchVdslVtuoMCMCurrSnrMgnread-onlycurrentShow the current SNR margin of upstream 1. This value is in units of 0.1 dB.
1.3.6.1.4.1.890.1.5.12.1.1.2.3.1.1.3ColumnaccessSwitchVdslVtuoMCMCurrTxPowerread-onlycurrentShow the current transmit power of downstream 1. This value is in units of 0.1 dBm.
1.3.6.1.4.1.890.1.5.12.1.1.2.3.1.1.4ColumnaccessSwitchVdslVtuoMCMCurrAttenuationread-onlycurrentShow the current transmit power of upstream 1. This value is in units of 0.1 dB.
1.3.6.1.4.1.890.1.5.12.1.1.2.3.1.1.5ColumnaccessSwitchVdslVtuoMCMCurrInterleaveDelayread-onlycurrentShow the current interleave delay of downstream. This value is in units of 0.5 ms.
1.3.6.1.4.1.890.1.5.12.1.1.2.3.1.1.6ColumnaccessSwitchVdslVtuoMCMCurrStatusread-onlycurrentIndicates current status of the upstream. This is a bit-map of possible conditions. The various bit positions are: 0 noDefect There is no defect on the line. 1…
1.3.6.1.4.1.890.1.5.12.1.1.2.3.2TableaccessSwitchVdslVturPhyMCMTablenot-accessiblecurrentThis table provides one row for each VTUR. Each row contains the Physical Layer Parameters table for that VTUR.
1.3.6.1.4.1.890.1.5.12.1.1.2.3.2.1RowaccessSwitchVdslVturPhyMCMEntrynot-accessiblecurrentAn entry in the accessSwitchVdslVturPhyMCMTable.
1.3.6.1.4.1.890.1.5.12.1.1.2.3.2.1.1ColumnaccessSwitchVdslVturMCMCurrLinkStateread-onlycurrentShow current state of the VTUR line. idle(0) - this VDSL line is not used. standby(1) - this VDSL line links down. show_time(2) - this VDSL line links up. trai…
1.3.6.1.4.1.890.1.5.12.1.1.2.3.2.1.2ColumnaccessSwitchVdslVturMCMCurrSnrMgnread-onlycurrentShow the current SNR margin of downstream 1. This value is in units of 0.5 dB.
1.3.6.1.4.1.890.1.5.12.1.1.2.3.2.1.3ColumnaccessSwitchVdslVturMCMCurrTxPowerread-onlycurrentShow the current transmit power of upstream 1. This value is in units of 0.5 dBm.
1.3.6.1.4.1.890.1.5.12.1.1.2.3.2.1.4ColumnaccessSwitchVdslVturMCMCurrAttenuationread-onlycurrentShow the current transmit power of downstream 1. This value is in units of 0.1 dB.
1.3.6.1.4.1.890.1.5.12.1.1.2.3.2.1.5ColumnaccessSwitchVdslVturMCMCurrInterleaveDelayread-onlycurrentShow the current interleave delay of upstream. This value is in units of 0.5 ms.
1.3.6.1.4.1.890.1.5.12.1.1.2.3.2.1.6ColumnaccessSwitchVdslVturMCMCurrStatusread-onlycurrentIndicates current status of the downstream. This is a bit-map of possible conditions. The various bit positions are: 0 noDefect There is no defect on the line.…