1.3.6.1.4.1.5504.4.17.1NodezhonePtpObjectID
1.3.6.1.4.1.5504.4.17.1.1TablezhonePtpConfigTablenot-accessiblecurrentTable of configuration values for the Precision Timing Protocol.
1.3.6.1.4.1.5504.4.17.1.1.1RowzhonePtpConfigEntrynot-accessiblecurrentRow in the PtpConfigTable
1.3.6.1.4.1.5504.4.17.1.1.1.1ColumnzhonePtpConfigIfIndexnot-accessiblecurrentIndex for this table.
1.3.6.1.4.1.5504.4.17.1.1.1.2ColumnzhonePtpConfigClockModeread-createcurrentDescribes the mode and function of this clock.
1.3.6.1.4.1.5504.4.17.1.1.1.3ColumnzhonePtpConfigSyncMsgIntervalread-createcurrentLog of mean time interval between successive Sync messages when transmitted as multicast messages.
1.3.6.1.4.1.5504.4.17.1.1.1.4ColumnzhonePtpConfigAnnounceIntervalread-createcurrentLog of time, in seconds, to send announce messages.
1.3.6.1.4.1.5504.4.17.1.1.1.5ColumnzhonePtpConfigDelayReqIntervalread-createcurrentLog of minimum permitted mean time between successive Delay_Req messages sent by a slave to a specific port on the master.
1.3.6.1.4.1.5504.4.17.1.1.1.6ColumnzhonePtpConfigDomain1MSread-createcurrentThe domain for this PTP. If clockMode is boundary, then this is the domain for the slave port.
1.3.6.1.4.1.5504.4.17.1.1.1.7ColumnzhonePtpConfigVarianceread-createcurrentLog of variance used in determination of the best master clock.
1.3.6.1.4.1.5504.4.17.1.1.1.8ColumnzhonePtpConfigPriority1read-createcurrentPrecedence value used in best master algorithm, if master.
1.3.6.1.4.1.5504.4.17.1.1.1.9ColumnzhonePtpConfigPriority2read-createcurrentPrecedence used in best master determination, if master
1.3.6.1.4.1.5504.4.17.1.1.1.10ColumnzhonePtpConfigDomain2Mread-createcurrentIf clockMode is boundary, then this is the domain for the master port. Otherwise, it is unused.
1.3.6.1.4.1.5504.4.17.1.1.1.11ColumnzhonePtpConfigRowStatusread-createcurrentRow status for this table.
1.3.6.1.4.1.5504.4.17.1.1.1.12ColumnzhonePtpConfigIpIfIndexread-createcurrentThe management ip index on this system.
1.3.6.1.4.1.5504.4.17.1.1.1.13ColumnzhonePtpConfigAcceptableMaster1read-createcurrentFirst acceptable PTP master.
1.3.6.1.4.1.5504.4.17.1.1.1.14ColumnzhonePtpConfigAcceptableMaster2read-createcurrentSecond acceptable PTP master.
1.3.6.1.4.1.5504.4.17.1.2TablezhonePtpStatusTablenot-accessiblecurrentThe read-only attributes associated with the 1588 module.
1.3.6.1.4.1.5504.4.17.1.2.1RowzhonePtpStatusEntrynot-accessiblecurrentA row in the zhonePtpStatusTable
1.3.6.1.4.1.5504.4.17.1.2.1.1ColumnzhonePtpStatusMacAddressread-onlycurrentThe ptpMacAddr is used to set the PTP ClockIdentifier defined in the PTP standard. It identifies the clock in the PTP network and as such should be unique with…
1.3.6.1.4.1.5504.4.17.1.2.1.2ColumnzhonePtpConfigTimeSourceread-onlycurrentTime source for the PTP.
1.3.6.1.4.1.5504.4.17.1.2.1.3ColumnzhonePtpConfigClockStratumread-onlycurrentIndicates the stratum level of the local clock.
1.3.6.1.4.1.5504.4.17.1.2.1.4ColumnzhonePtpConfigClockAccuracyread-onlycurrentAccuracy of this clock. Used in determining best master clock.
1.3.6.1.4.1.5504.4.17.1.2.1.5ColumnzhonePtpStatusTxModeread-onlycurrentBy default, Semtech sends multicast messages (e.g. Announce Messages) if they are meant for more than one node. Messages destined to a single node are sent as …
1.3.6.1.4.1.5504.6.119IdentityzhonePtpModuleManaged data objects for Zhone's 1588 Precision Timing Protocol.