MIB Viewer

adtran/ADTRAN-GEN-Y1731-MIB

253 objects
This MIB defines the objects for the Y.1731 MIB.
OIDNameAccessStatusDescription
1.3.6.1.4.1.664.5.75.2.1NodeadGenY1731MIBObjects
1.3.6.1.4.1.664.5.75.2.1.1NodeadGenY1731Config
1.3.6.1.4.1.664.5.75.2.1.1.1ScalaradGenY1731Enableread-writecurrentThis OID is used to enable/disable Y.1731.
1.3.6.1.4.1.664.5.75.2.1.1.2ScalaradGenY1731BulkDataExportIntervalread-writecurrentThe interval, in seconds, between Y.1731 PM file transfers to the management server. The interval must be between 30 and 300 seconds. The default interval valu…
1.3.6.1.4.1.664.5.75.2.1.1.3ScalaradGenY1731LinktraceCacheHoldTimeread-writecurrentThe Linktrace cache hold time specified in minutes. Linktrace replies in the Linktrace Reply Table (adGenY1731LocalMepLtrTable) will age out after the configur…
1.3.6.1.4.1.664.5.75.2.1.1.4ScalaradGenY1731LinktraceCacheSizeread-writecurrentThe Linktrace cache size is the maximum entries that can be added stored in the Linktrace Reply Table (adGenY1731LocalMepLtrTable). Once the maximum size is re…
1.3.6.1.4.1.664.5.75.2.1.2NodeadGenY1731Meg
1.3.6.1.4.1.664.5.75.2.1.2.1ScalaradGenY1731MegMaxNumberread-onlycurrentMaximum number of allowed Maintenenance Entity Groups.
1.3.6.1.4.1.664.5.75.2.1.2.2ScalaradGenY1731MegCurrentNumberread-onlycurrentCurrent number of MEGs.
1.3.6.1.4.1.664.5.75.2.1.2.3ScalaradGenY1731MegLastCreateErrorread-onlycurrentThe reason for the last error that occured while attempting to create an entry in the Maintenance Entity Group Table (adGenY1731MegTable).
1.3.6.1.4.1.664.5.75.2.1.2.4TableadGenY1731MegTablenot-accessiblecurrentThe Y.1731 MEG table.
1.3.6.1.4.1.664.5.75.2.1.2.4.1RowadGenY1731MegEntrynot-accessiblecurrentAn entry in the Y.1731 MEG table.
1.3.6.1.4.1.664.5.75.2.1.2.4.1.1ColumnadGenY1731MegLevelnot-accessiblecurrentMEG level for the MEG.
1.3.6.1.4.1.664.5.75.2.1.2.4.1.2ColumnadGenY1731MegNameFormatnot-accessiblecurrentchar-string - This is an IETF RFC 2579 DisplayString, with the exception that the character codes 0-31 (decimal) are not used. icc-umc - this consists of two s…
1.3.6.1.4.1.664.5.75.2.1.2.4.1.3ColumnadGenY1731MegNameLengthAndNamenot-accessiblecurrentIf adGenY1731MegNameFormat is char-string or icc-umc - The First octet represents the total length in octets of the MEG Name. Octets 2-46 represent the MEG Nam…
1.3.6.1.4.1.664.5.75.2.1.2.4.1.4ColumnadGenY1731MegRowStatusread-createcurrentThis OID is used to create and delete the MEG. The only supported settings are createAndGo, createAndWait, and destroy.
1.3.6.1.4.1.664.5.75.2.1.2.4.1.5ColumnadGenY1731MegServiceTypeValueListread-createcurrentOctet string which defines the service type and value that maintenance points in the MEG reside and operate on. Expected format: First octet represents the ove…
1.3.6.1.4.1.664.5.75.2.1.2.4.1.6ColumnadGenY1731MegCcmIntervalread-createcurrentInterval between CCM transmissions to be used by all MEPs in the MEG. Default value is 1-second.
1.3.6.1.4.1.664.5.75.2.1.2.4.1.7ColumnadGenY1731MegLocalMepConfigTableLastCreateErrorread-onlycurrentThe reason for the last error that occured while attempting to create an entry in the MEG's local MEP Config Table (adGenY1731LocalMepConfigTable).
1.3.6.1.4.1.664.5.75.2.1.2.4.1.8ColumnadGenY1731MegDisplayNameread-onlycurrentRepresents the MEG Name associated with the MEG.
1.3.6.1.4.1.664.5.75.2.1.2.5NodeadGenY1731MegMepList
1.3.6.1.4.1.664.5.75.2.1.2.5.1NodeadGenY1731MegMepListScalars
1.3.6.1.4.1.664.5.75.2.1.2.5.1.1ScalaradGenY1731MegMepListMaxNumberread-onlycurrentMaximum number of allowed Maintenenance End Points that the device supports. The number is the sum of all entries present in the local MEP table and the local …
1.3.6.1.4.1.664.5.75.2.1.2.5.1.2ScalaradGenY1731MegMepListCurrentNumberread-onlycurrentCurrent number of MEPs in the MEG's list of MEPs.
1.3.6.1.4.1.664.5.75.2.1.2.5.1.3ScalaradGenY1731MegMepListTableLastCreateErrorread-onlycurrentThe reason for the last error that occured while attempting to create an entry in the MEG MEP List (adGenY1731MegMepListTable).
1.3.6.1.4.1.664.5.75.2.1.2.5.2TableadGenY1731MegMepListTablenot-accessiblecurrentThe list of all MEPs in the MEG. For a device to create a local MEP it will need to create an entry in the adGenY1731LocalMepConfigTable. Once a local MEP is c…
1.3.6.1.4.1.664.5.75.2.1.2.5.2.1RowadGenY1731MegMepListEntrynot-accessiblecurrentAn entry in the Y.1731 MEG MEP list table.
1.3.6.1.4.1.664.5.75.2.1.2.5.2.1.1ColumnadGenY1731MegMepListIdentifiernot-accessiblecurrentInteger that is unique among all the MEPs in the same MEG. Other definition is: a small integer, unique over a given Maintenance Entity Group, identifying a sp…
1.3.6.1.4.1.664.5.75.2.1.2.5.2.1.2ColumnadGenY1731MegMepListRowStatusread-createcurrentThis OID is used to create/delete the MEG MEP list entry. The only supported settings are createAndGo, createAndWait, and destroy.
1.3.6.1.4.1.664.5.75.2.1.3NodeadGenY1731LocalMep
1.3.6.1.4.1.664.5.75.2.1.3.1NodeadGenY1731LocalMepConfig
1.3.6.1.4.1.664.5.75.2.1.3.1.1NodeadGenY1731LocalMepConfigScalars
1.3.6.1.4.1.664.5.75.2.1.3.1.1.1ScalaradGenY1731LocalMepMaxNumberread-onlycurrentMaximum number of allowed local Maintenenance End Points.
1.3.6.1.4.1.664.5.75.2.1.3.1.1.2ScalaradGenY1731LocalMepCurrentNumberread-onlycurrentCurrent number of local MEPs.
1.3.6.1.4.1.664.5.75.2.1.3.1.1.3ScalaradGenY1731LocalMepConfigTableLastCreateErrorread-onlycurrentThe reason for the last error that occured while attempting to create an entry in the local MEP Table (adGenY1731LocalMepConfigTable).
1.3.6.1.4.1.664.5.75.2.1.3.1.2TableadGenY1731LocalMepConfigTablenot-accessiblecurrentThe Y.1731 local MEP table. A local MEP is one that resides on an interface of the system.
1.3.6.1.4.1.664.5.75.2.1.3.1.2.1RowadGenY1731LocalMepConfigEntrynot-accessiblecurrentAn entry in the Y.1731 local MEP table.
1.3.6.1.4.1.664.5.75.2.1.3.1.2.1.1ColumnadGenY1731LocalMepIdentifiernot-accessiblecurrentInteger that is unique among all the MEPs in the same MEG. Other definition is: a small integer, unique over a given Maintenance Entity Group, identifying a sp…
1.3.6.1.4.1.664.5.75.2.1.3.1.2.1.2ColumnadGenY1731LocalMepRowStatusread-createcurrentThis OID is used to create/delete the MEP. The only supported settings are createAndGo, createAndWait, and destroy.
1.3.6.1.4.1.664.5.75.2.1.3.1.2.1.3ColumnadGenY1731LocalMepStatusread-onlycurrentOperational status of the MEP. The minimum attributes that need to be set before a MEP can transition to running are: ifIndex, direction, and admin state.
1.3.6.1.4.1.664.5.75.2.1.3.1.2.1.4ColumnadGenY1731LocalMepStatusStringread-onlycurrentOperational status string of the MEP. If the MEP is expected to be active but is not able to be due to a provisioning issue or conflict, this string will expla…
1.3.6.1.4.1.664.5.75.2.1.3.1.2.1.5ColumnadGenY1731LocalMepIfIndexread-createcurrentThis object is the interface index of the interface either a bridge port, or an aggregated IEEE 802.1 link within a bridge port, to which the MEP is attached. …
1.3.6.1.4.1.664.5.75.2.1.3.1.2.1.6ColumnadGenY1731LocalMepDirectionread-createcurrentThe direction in which the MEP faces on the Bridge port.
1.3.6.1.4.1.664.5.75.2.1.3.1.2.1.7ColumnadGenY1731LocalMepAdminStateread-createcurrentThe administrative state of the MEP. Enable indicates that the MEP is to function normally, and disable that it is to cease functioning.
1.3.6.1.4.1.664.5.75.2.1.3.1.2.1.8ColumnadGenY1731LocalMepVlanPriorityread-createcurrentThe priority value for messages transmitted by the MEP. Default value is the highest priority value for the service which is assumed to be 7. The management en…
1.3.6.1.4.1.664.5.75.2.1.3.1.2.1.9ColumnadGenY1731LocalMepCcmEnabledread-createcurrentIf set to true, the MEP will generate CCM messages.
1.3.6.1.4.1.664.5.75.2.1.3.2NodeadGenY1731LocalMepRmepDb
1.3.6.1.4.1.664.5.75.2.1.3.2.1NodeadGenY1731LocalMepRmepDbScalars
1.3.6.1.4.1.664.5.75.2.1.3.2.1.1ScalaradGenY1731LocalMepRmepDbMaxNumberread-onlycurrentA systemwide value representing the maximum number of remote Maintenance End Points that can be created across all Local MEPs on the device.
1.3.6.1.4.1.664.5.75.2.1.3.2.1.2ScalaradGenY1731LocalMepRmepDbCurrentNumberread-onlycurrentCurrent number of remote MEPs.
1.3.6.1.4.1.664.5.75.2.1.3.2.2TableadGenY1731LocalMepRmepDbTablenot-accessiblecurrentThe RMEP database table for a given local MEP. Maintains information and status for each RMEP of a local MEP.
1.3.6.1.4.1.664.5.75.2.1.3.2.2.1RowadGenY1731LocalMepRmepDbEntrynot-accessiblecurrentAn entry in the a local MEP's RMEP database table. An RMEP associated with a specific local MEP
1.3.6.1.4.1.664.5.75.2.1.3.2.2.1.1ColumnadGenY1731RemoteMepIdentifiernot-accessiblecurrentInteger that is unique among all the MEPs in the same MEG. Other definition is: a small integer, unique over a given Maintenance Entity Group, identifying a sp…
1.3.6.1.4.1.664.5.75.2.1.3.2.2.1.2ColumnadGenY1731RemoteMepStatusread-onlycurrentStatus of the RMEP. Status of idle indicates the local MEP associated with this RMEP entry is not in the active state. Status of okay indicates the local MEP i…
1.3.6.1.4.1.664.5.75.2.1.3.2.2.1.3ColumnadGenY1731RemoteMepFailedOkTimeread-onlycurrentThe time (SysUpTime) at which the RMEP state machine last entered either the idle, okay, or failed state. The value is the time since the device started up and…
1.3.6.1.4.1.664.5.75.2.1.3.2.2.1.4ColumnadGenY1731RemoteMepMacAddressread-onlycurrentThe MAC address of the remote MEP.
1.3.6.1.4.1.664.5.75.2.1.3.2.2.1.5ColumnadGenY1731RemoteMepLastCcmSequenceNumberread-onlycurrentSequence number in last CCM received from the remote MEP.
1.3.6.1.4.1.664.5.75.2.1.3.2.2.1.6ColumnadGenY1731RemoteMepRdiread-onlycurrentState of the RDI bit in the last received CCM (true for RDI=1), or false if none has been received.
1.3.6.1.4.1.664.5.75.2.1.3.2.2.1.7ColumnadGenY1731RemoteMepPortStatusread-onlycurrentAn enumerated value of the Port Status TLV received in the last CCM from the remote MEP. The default value psNoPortStatusTlv is returned if no CCM has been rec…
1.3.6.1.4.1.664.5.75.2.1.3.2.2.1.8ColumnadGenY1731RemoteMepInterfaceStatusread-onlycurrentAn enumerated value of the Interface status TLV received in the last CCM from the remote MEP. The the default value isNoInterfaceStatus TLV is returned if eith…
1.3.6.1.4.1.664.5.75.2.1.3.2.2.1.9ColumnadGenY1731RemoteMepChassisIdSubtyperead-onlycurrentSpecifies the format of the Chassis ID received in the last CCM. If the Chassis ID field was not included in the Sender ID TLV received, the value nonePresent(…
1.3.6.1.4.1.664.5.75.2.1.3.2.2.1.10ColumnadGenY1731RemoteMepChassisIdread-onlycurrentChassis ID received in the last CCM format of which is determined by the value of adGenY1731RemoteMepChassisIdSubtype.
1.3.6.1.4.1.664.5.75.2.1.3.2.2.1.11ColumnadGenY1731RemoteMepManAddressDomainread-onlycurrentThe TDomain that identifies the type and format of the related adGenY1731RemoteMepManAddress object, used to access the SNMP agent of the system transmitting t…
1.3.6.1.4.1.664.5.75.2.1.3.2.2.1.12ColumnadGenY1731RemoteMepManAddressread-onlycurrentThe TAddress that can be used to access the SNMP agent of the system transmitting the CCM. This is received in the CCM Sender ID TLV from that system. If the r…
1.3.6.1.4.1.664.5.75.2.1.3.3NodeadGenY1731LocalMepLbm
1.3.6.1.4.1.664.5.75.2.1.3.3.1TableadGenY1731LocalMepLbmTransmitTablenot-accessiblecurrentThe Y.1731 Local MEP Loopback Transmit table. A Local MEP is one that resides on an interface of the system. This table will enable the user to configure a Loc…
1.3.6.1.4.1.664.5.75.2.1.3.3.1.1RowadGenY1731LocalMepLbmTransmitEntrynot-accessiblecurrentAn entry in the Y.1731 Local MEP Loopback Transmit table.
1.3.6.1.4.1.664.5.75.2.1.3.3.1.1.1ColumnadGenY1731LocalMepLbmStatusread-onlycurrentA Boolean flag where true means the MEP is actively sending LBM messages and false means that no LBMs are being transmitted.
1.3.6.1.4.1.664.5.75.2.1.3.3.1.1.2ColumnadGenY1731LocalMepLbmConfigStatusread-writecurrentTrue means the MEP is ready for configuring LBM and a false means the MEP is under LBM configuration. This flag is used to prevent simultaneous configuration b…
1.3.6.1.4.1.664.5.75.2.1.3.3.1.1.3ColumnadGenY1731LocalMepLbmDestMacAddressread-writecurrentThe Target MAC Address Field to be transmitted. This is a unicast destination MAC address. This address will be used if the value of the column adGenY1731Local…
1.3.6.1.4.1.664.5.75.2.1.3.3.1.1.4ColumnadGenY1731LocalMepLbmDestMepIdread-writecurrentThe MEG End Point Identifier of another MEP in the same MEG to which the LBM is to be sent. This address will be used if the value of the column adGenY1731Loca…
1.3.6.1.4.1.664.5.75.2.1.3.3.1.1.5ColumnadGenY1731LocalMepLbmDestIsMepIdread-writecurrentTrue indicates that MEPID of the target MEP is used for Loopback transmission. False indicates that unicast destination MAC address of the target MEP is used f…
1.3.6.1.4.1.664.5.75.2.1.3.3.1.1.6ColumnadGenY1731LocalMepLbmMessageCountread-writecurrentThe number of Loopback messages to be transmitted.
1.3.6.1.4.1.664.5.75.2.1.3.3.1.1.7ColumnadGenY1731LocalMepLbmActiveread-writecurrentStart or stop LBM transmission. By writing true, start LBM transmisson. By writing false, stop LBM transmission
1.3.6.1.4.1.664.5.75.2.1.3.3.1.1.8ColumnadGenY1731LocalMepLbmDataTlvread-writecurrentAn arbitrary amount of data to be included in the Data TLV, if the Data TLV is selected to be sent.
1.3.6.1.4.1.664.5.75.2.1.3.3.1.1.9ColumnadGenY1731LocalMepLbmVlanPriorityread-writecurrentThe 3 bit priority value to be used in the VLAN tag, if present, in the transmitted frame. The default value is CCM priority.
1.3.6.1.4.1.664.5.75.2.1.3.3.1.1.10ColumnadGenY1731LocalMepLbmVlanDropEnableread-writecurrentDrop Enable bit value to be used in the VLAN tag, if present in the transmitted frame. For more information about VLAN Drop Enable, please check IEEE 802.1ad.
1.3.6.1.4.1.664.5.75.2.1.3.3.1.1.11ColumnadGenY1731LocalMepLbmErrorStatusread-onlycurrentMEP Loopback error status.
1.3.6.1.4.1.664.5.75.2.1.3.3.1.1.12ColumnadGenY1731LocalMepLbmTimeoutread-writecurrentMEP Loopback Timeout in milliseconds.
1.3.6.1.4.1.664.5.75.2.1.3.3.1.1.13ColumnadGenY1731LocalMepLbmInterframeDelayread-writecurrentMEP Loopback Interframe Delay in milliseconds.
1.3.6.1.4.1.664.5.75.2.1.3.3.1.1.14ColumnadGenY1731LocalMepLbmNextTransIdread-onlycurrentNext transaction identifier to be sent in a Loopback message. This transaction identifier can be zero because it wraps around.
1.3.6.1.4.1.664.5.75.2.1.3.3.1.1.15ColumnadGenY1731LocalMepLbmSizeread-writecurrentSize of the LBM in bytes. The size encompasses the entire Ethernet frame from the header through the FCS. The supported values are: 0 to indicate Data TLV shou…
1.3.6.1.4.1.664.5.75.2.1.3.3.1.1.16ColumnadGenY1731LocalMepValidateDataread-writecurrentA Boolean flag where true means the data sent in LBM message has to be validated with the LBR. False indicates no validation is required.
1.3.6.1.4.1.664.5.75.2.1.3.3.2TableadGenY1731LocalMepLbmResultTablenot-accessiblecurrentThe Y.1731 Local MEP Loopback Result table. A Local MEP is one that resides on an interface of the system. This table can be used to query the results and coun…
1.3.6.1.4.1.664.5.75.2.1.3.3.2.1RowadGenY1731LocalMepLbmResultEntrynot-accessiblecurrentAn entry in the Y.1731 Local MEP Loopback Result table.
1.3.6.1.4.1.664.5.75.2.1.3.3.2.1.1ColumnadGenY1731LocalMepLbrResultOkread-onlycurrentIndicates the result of the operation: - true The Loopback Message(s) will be (or has been) sent. - false The Loopback Message(s) will not be sent.
1.3.6.1.4.1.664.5.75.2.1.3.3.2.1.2ColumnadGenY1731LocalMepLbrResponseTimeMinread-onlycurrentMinimum LBR round-trip time (in milliseconds).
1.3.6.1.4.1.664.5.75.2.1.3.3.2.1.3ColumnadGenY1731LocalMepLbrResponseTimeMaxread-onlycurrentMaximum LBR round-trip time (in milliseconds).
1.3.6.1.4.1.664.5.75.2.1.3.3.2.1.4ColumnadGenY1731LocalMepLbrResponseTimeAvgread-onlycurrentAverage LBR round-trip time (in milliseconds).
1.3.6.1.4.1.664.5.75.2.1.3.3.2.1.5ColumnadGenY1731LocalMepLbrInread-onlycurrentTotal number of valid, Loopback Replies received.
1.3.6.1.4.1.664.5.75.2.1.3.3.2.1.6ColumnadGenY1731LocalMepLbrInOutOfOrderread-onlycurrentThe total number of valid, out-of-order Loopback Replies received.
1.3.6.1.4.1.664.5.75.2.1.3.3.2.1.7ColumnadGenY1731LocalMepLbrBadMsduread-onlycurrentThe total number of LBRs received whose mac_service_data_unit did not match (except for the OpCode) that of the corresponding LBM.
1.3.6.1.4.1.664.5.75.2.1.3.3.2.1.8ColumnadGenY1731LocalMepLbmOutread-onlycurrentThe total number of LBMs transmitted.
1.3.6.1.4.1.664.5.75.2.1.3.3.3TableadGenY1731LocalMepLbmResponderTablenot-accessiblecurrentThe Y.1731 Local MEP Loopback Responder table. A Local MEP is one that resides on an interface of the system. This table can be used to query the counters rela…
1.3.6.1.4.1.664.5.75.2.1.3.3.3.1RowadGenY1731LocalMepLbmResponderEntrynot-accessiblecurrentAn entry in the Y.1731 Local MEP Loopback Responder table.
1.3.6.1.4.1.664.5.75.2.1.3.3.3.1.1ColumnadgenY1731LocalMepLbrOutread-onlycurrentTotal number of Loopback Replies transmitted.
1.3.6.1.4.1.664.5.75.2.1.3.3.3.1.2ColumnadGenY1731LocalMepLbmInread-onlycurrentTotal number of valid, Loopback Messages received.
1.3.6.1.4.1.664.5.75.2.1.3.4NodeadGenY1731LocalMepDmm
1.3.6.1.4.1.664.5.75.2.1.3.4.1NodeadGenY1731DmmScalars
1.3.6.1.4.1.664.5.75.2.1.3.4.1.1ScalaradGenY1731DmmSessionMaxNumberread-onlycurrentA systemwide value representing the maximum number of DMM sessions that can be created across all local MEPs on the device.
1.3.6.1.4.1.664.5.75.2.1.3.4.1.2ScalaradGenY1731DmmSessionCurrentNumberread-onlycurrentCurrent number of DMM sessions created.
1.3.6.1.4.1.664.5.75.2.1.3.4.1.3ScalaradGenY1731DmmSessionLastCreateErrorread-onlycurrentThe reason for the last error that occurred while attempting to create an DMM Session Transmit entry (adGenY1731DmmSessionTransmitEntry).
1.3.6.1.4.1.664.5.75.2.1.3.4.2TableadGenY1731DmmSessionTransmitTablenot-accessiblecurrentThe two-way frame-delay (DMM) session table for a given local MEP. A local MEP's DMM sessions can be created, edited, and deleted using this table. A local MEP…
1.3.6.1.4.1.664.5.75.2.1.3.4.2.1RowadGenY1731DmmSessionTransmitEntrynot-accessiblecurrentA two-way frame-delay (DMM) performance monitoring session of a local MEP. A DMM PM session is unique based on target identifier and VLAN priority. The target …
1.3.6.1.4.1.664.5.75.2.1.3.4.2.1.1ColumnadGenY1731DmmSessionTargetRmepIdOrMacAddressnot-accessiblecurrentIndicates whether the target specified is a MEPID or a unicast MAC Address. If the target specified is a MEPID, the local MEP will not be able to initiate the …
1.3.6.1.4.1.664.5.75.2.1.3.4.2.1.2ColumnadGenY1731DmmSessionTargetnot-accessiblecurrentOctet string defining the target for the DMM session. If adGenY1731DmmSessionTargetRmepIdOrMacAddress indicates the target is a MEPID then the octet string sho…
1.3.6.1.4.1.664.5.75.2.1.3.4.2.1.3ColumnadGenY1731DmmSessionVlanPrioritynot-accessiblecurrentVLAN Priority that will be used in all DMM frames sent by this DMM transmit session.
1.3.6.1.4.1.664.5.75.2.1.3.4.2.1.4ColumnadGenY1731DmmSessionTargetRemoteMepIdentifierread-onlycurrentTarget MEPID for this DMM session
1.3.6.1.4.1.664.5.75.2.1.3.4.2.1.5ColumnadGenY1731DmmSessionTargetMacAddressread-onlycurrentTarget MAC address for this DMM session
1.3.6.1.4.1.664.5.75.2.1.3.4.2.1.6ColumnadGenY1731DmmSessionRowStatusread-createcurrentThis OID is used to create/delete a transmit DMM session of a Local MEP. The only supported settings are createAndGo, createAndWait, and destroy.
1.3.6.1.4.1.664.5.75.2.1.3.4.2.1.7ColumnadGenY1731DmmSessionAdminStateread-createcurrentThe administrative state of the DMM transmit session. True indicates that the DMM session is to function normally and actively transmit DMMs towards the specif…
1.3.6.1.4.1.664.5.75.2.1.3.4.2.1.8ColumnadGenY1731DmmSessionStatusread-onlycurrentOperational status of the DMM transmit session. The minimum attributes that need to be set before a MEP can transmit DMMs towards the target are: Target MEPID …
1.3.6.1.4.1.664.5.75.2.1.3.4.2.1.9ColumnadGenY1731DmmSessionStatusStringread-onlycurrentOperational status string of the DMM transmit session. If the session is expected to be active but is not able to be due to a provisioning issue or conflict, t…
1.3.6.1.4.1.664.5.75.2.1.3.4.2.1.10ColumnadGenY1731DmmSessionInterframeDelayread-createcurrentAmount of time in milliseconds between DMM transmissions. The supported range is 100 - 10,000 ms and the default value is 1000 ms.
1.3.6.1.4.1.664.5.75.2.1.3.4.2.1.11ColumnadGenY1731DmmSessionMeasurementIntervalread-createcurrentInterval in seconds over which statistics are generated. The supported range is 60 - 900 seconds and the default value is 60. The statistics calculated for a m…
1.3.6.1.4.1.664.5.75.2.1.3.4.2.1.12ColumnadGenY1731DmmSessionSizeread-createcurrentSize of the DMM in bytes. The size encompasses the entire Ethernet frame from the header through the FCS. The supported values are: 0 to indicate Data TLV shou…
1.3.6.1.4.1.664.5.75.2.1.3.4.2.1.13ColumnadGenY1731DmmSessionDataread-createcurrentData pattern to be used when padding is required to meet the size setting. The default value is 0x00 0x00.
1.3.6.1.4.1.664.5.75.2.1.3.4.2.1.14ColumnadGenY1731DmmSessionBulkDataExportFileTypesread-createcurrentDetermines which, if any, files are generated by this DMM transmit session. The files are used to store two-way frame-delay statistics. The average setting wil…
1.3.6.1.4.1.664.5.75.2.1.3.5NodeadGenY1731LocalMepLmm
1.3.6.1.4.1.664.5.75.2.1.3.5.1NodeadGenY1731LmmScalars
1.3.6.1.4.1.664.5.75.2.1.3.5.1.1ScalaradGenY1731LmmSessionMaxNumberread-onlycurrentA systemwide value representing the maximum number of LMM sessions that can be created across all local MEPs on the device.
1.3.6.1.4.1.664.5.75.2.1.3.5.1.2ScalaradGenY1731LmmSessionCurrentNumberread-onlycurrentCurrent number of LMM sessions created.
1.3.6.1.4.1.664.5.75.2.1.3.5.1.3ScalaradGenY1731LmmSessionLastCreateErrorread-onlycurrentThe reason for the last error that occurred while attempting to create an LMM Session Transmit entry (adGenY1731LmmSessionTransmitEntry).
1.3.6.1.4.1.664.5.75.2.1.3.5.2TableadGenY1731LmmSessionTransmitTablenot-accessiblecurrentThe single-ended frame-loss (LMM) session table for a given local MEP. A local MEP's LMM sessions can be created, edited, and deleted using this table. A local…
1.3.6.1.4.1.664.5.75.2.1.3.5.2.1RowadGenY1731LmmSessionTransmitEntrynot-accessiblecurrentA single-ended frame-loss (LMM) performance monitoring session of a local MEP. A LMM PM session is unique based on target identifier and VLAN priority. The tar…
1.3.6.1.4.1.664.5.75.2.1.3.5.2.1.1ColumnadGenY1731LmmSessionTargetRmepIdOrMacAddressnot-accessiblecurrentIndicates whether the target specified is a MEPID or a unicast MAC Address. If the target specified is a MEPID the local MEP will not be able to initiate the L…
1.3.6.1.4.1.664.5.75.2.1.3.5.2.1.2ColumnadGenY1731LmmSessionTargetnot-accessiblecurrentOctet string defining the target for the LMM session. If adGenY1731LmmSessionTargetRmepIdOrMacAddress indicates the target is a MEPID then the octet string sho…
1.3.6.1.4.1.664.5.75.2.1.3.5.2.1.3ColumnadGenY1731LmmSessionVlanPrioritynot-accessiblecurrentVLAN Priority that will be used in all LMM frames sent by this LMM transmit session.
1.3.6.1.4.1.664.5.75.2.1.3.5.2.1.4ColumnadGenY1731LmmSessionTargetRemoteMepIdentifierread-onlycurrentTarget MEPID for this LMM session
1.3.6.1.4.1.664.5.75.2.1.3.5.2.1.5ColumnadGenY1731LmmSessionTargetMacAddressread-onlycurrentTarget MAC address for this LMM session
1.3.6.1.4.1.664.5.75.2.1.3.5.2.1.6ColumnadGenY1731LmmSessionRowStatusread-createcurrentThis OID is used to create/delete a transmit LMM session of a Local MEP. The only supported settings are createAndGo, createAndWait, and destroy.
1.3.6.1.4.1.664.5.75.2.1.3.5.2.1.7ColumnadGenY1731LmmSessionAdminStateread-createcurrentThe administrative state of the LMM transmit session. True indicates that the LMM session is to function normally and actively transmit LMMs towards the specif…
1.3.6.1.4.1.664.5.75.2.1.3.5.2.1.8ColumnadGenY1731LmmSessionStatusread-onlycurrentOperational status of the LMM transmit session. The minimum attributes that need to be set before a MEP can transmit LMMs towards the target are: Target MEPID …
1.3.6.1.4.1.664.5.75.2.1.3.5.2.1.9ColumnadGenY1731LmmSessionStatusStringread-onlycurrentOperational status string of the LMM transmit session. If the session is expected to be active but is not able to be due to a provisioning issue or conflict, t…
1.3.6.1.4.1.664.5.75.2.1.3.5.2.1.10ColumnadGenY1731LmmSessionInterframeDelayread-createcurrentAmount of time in milliseconds between LMM transmissions. The supported range is 100 - 10,000 ms and the default value is 1000 ms.
1.3.6.1.4.1.664.5.75.2.1.3.5.2.1.11ColumnadGenY1731LmmSessionMeasurementIntervalread-createcurrentInterval in seconds over which statistics are generated. The supported range is 60 - 900 seconds and the default value is 60. The statistics calculated for a m…
1.3.6.1.4.1.664.5.75.2.1.3.5.2.1.12ColumnadGenY1731LmmSessionSizeread-createcurrentSize of the LMM in bytes. The size encompasses the entire Ethernet frame from the header through the FCS. The supported values are: 0 to indicate Data TLV shou…
1.3.6.1.4.1.664.5.75.2.1.3.5.2.1.13ColumnadGenY1731LmmSessionDataread-createcurrentData pattern to be used when padding is required to meet the size setting. The default value is 0x00 0x00.
1.3.6.1.4.1.664.5.75.2.1.3.5.2.1.14ColumnadGenY1731LmmSessionBulkDataExportFileTypesread-createcurrentDetermines which, if any, files are generated by this LMM transmit session. The files are used to store single-ended frame-loss statistics. The average setting…
1.3.6.1.4.1.664.5.75.2.1.3.6NodeadGenY1731LocalMepLtm
1.3.6.1.4.1.664.5.75.2.1.3.6.1TableadGenY1731LocalMepLtmTablenot-accessiblecurrentThe Y.1731 Local MEP Linktrace table. A Local MEP is one that resides on an interface of the system. This table will enable the user to configure in preparatio…
1.3.6.1.4.1.664.5.75.2.1.3.6.1.1RowadGenY1731LocalMepLtmEntrynot-accessiblecurrentAn entry in the Y.1731 Local MEP Linktrace table.
1.3.6.1.4.1.664.5.75.2.1.3.6.1.1.1ColumnadGenY1731LocalMepLtmNextTransactionIdread-onlycurrentNext transaction identifier to be sent in a Linktrace message. This transaction identifier value can be zero because it wraps around.
1.3.6.1.4.1.664.5.75.2.1.3.6.1.1.2ColumnadGenY1731LocalMepUnexpLtrInread-onlycurrentThe total number of unexpected LTRs received.
1.3.6.1.4.1.664.5.75.2.1.3.6.1.1.3ColumnadGenY1731LocalMepTransmitLtmStatusread-onlycurrentA Boolean flag set to true by the bridge port to indicate that another LTM may be transmitted. Reset to false by the MEP Linktrace Initiator State Machine.
1.3.6.1.4.1.664.5.75.2.1.3.6.1.1.4ColumnadGenY1731LocalMepTransmitLtmFlagsread-writecurrentThe flags field for LTMs transmitted by the MEP.
1.3.6.1.4.1.664.5.75.2.1.3.6.1.1.5ColumnadGenY1731LocalMepTransmitLtmTargetMacAddressread-writecurrentThe Target MAC Address Field to be transmitted: A unicast destination MAC address. This address will be used if the value of the column adGenY1731LocalMepTrans…
1.3.6.1.4.1.664.5.75.2.1.3.6.1.1.6ColumnadGenY1731LocalMepTransmitLtmTargetMepIdread-writecurrentAn indication of the Target MAC Address Field to be transmitted. The MAC address to be used will be retrieved from the Local MEP's Remote MEP database by using…
1.3.6.1.4.1.664.5.75.2.1.3.6.1.1.7ColumnadGenY1731LocalMepTransmitLtmTargetIsMepIdread-writecurrentTrue indicates that MEPID of the target MEP is used for Linktrace transmission. False indicates that unicast destination MAC address of the target MEP is used …
1.3.6.1.4.1.664.5.75.2.1.3.6.1.1.8ColumnadGenY1731LocalMepTransmitLtmTtlread-writecurrentThe LTM TTL field. Default value, if not specified, is 64. The TTL field indicates the number of hops remaining to the LTM. Decremented by 1 by each Linktrace …
1.3.6.1.4.1.664.5.75.2.1.3.6.1.1.9ColumnadGenY1731LocalMepTransmitLtmResultread-onlycurrentIndicates the result of the operation: true The Linktrace Message will be (or has been) sent. false The Linktrace Message will not be sent.
1.3.6.1.4.1.664.5.75.2.1.3.6.1.1.10ColumnadGenY1731LocalMepTransmitLtmTransactionIdread-onlycurrentThe LTM Transaction Identifier (adGenY1731LocalMepLtmNextTransactionId) of the LTM sent. The value returned is undefined if adGenY1731LocalMepTransmitLtmResult…
1.3.6.1.4.1.664.5.75.2.1.3.6.1.1.11ColumnadGenY1731LocalMepTransmitLtmEgressIdentifierread-onlycurrentIdentifies the MEP Linktrace Initiator that is originating, or the Linktrace Responder that is forwarding, this LTM. The low-order six octets contain a 48-bit …
1.3.6.1.4.1.664.5.75.2.1.3.6.1.1.12ColumnadGenY1731LocalMepTransmitLtmStatusStringread-onlycurrentLinktrace error status contains a string indicating the reason they the Lintkrace transmission attempt failed.
1.3.6.1.4.1.664.5.75.2.1.3.6.1.1.13ColumnadGenY1731LocalMepTransmitLtmConfigStatusread-writecurrentTrue means the MEP is ready for configuring LTM and a false means the MEP is under LTM configuration. This flag is used to prevent simultaneous configuration b…
1.3.6.1.4.1.664.5.75.2.1.3.6.1.1.14ColumnadGenY1731LocalMepLtmActiveread-writecurrentStart or stop LTM transmission. By writing true, start LTM transmisson. By writing false, stop LTM transmission
1.3.6.1.4.1.664.5.75.2.1.3.6.1.1.15ColumnadGenY1731LocalMepLtmTotalOutread-onlycurrentThe total number of LTMs transmitted by the Local MEP.
1.3.6.1.4.1.664.5.75.2.1.3.6.1.1.16ColumnadGenY1731LocalMepLtrTotalInread-onlycurrentThe total number of LTRs received by the Local MEP.
1.3.6.1.4.1.664.5.75.2.1.3.6.1.1.17ColumnadGenY1731LocalMepLtrTotalInvalidInread-onlycurrentThe total number of invalid LTRs received by the Local MEP.
1.3.6.1.4.1.664.5.75.2.1.3.6.1.1.18ColumnadGenY1731LocalMepLtrTotalValidInread-onlycurrentThe total number of valid LTRs received by the Local MEP.
1.3.6.1.4.1.664.5.75.2.1.3.6.2TableadGenY1731LocalMepLtSessionTablenot-accessiblecurrentThe Y.1731 Local MEP Linktrace session table. This table contains a list of Linktrace sessions and the counters associated with each session.
1.3.6.1.4.1.664.5.75.2.1.3.6.2.1RowadGenY1731LocalMepLtSessionEntrynot-accessiblecurrentAn entry in the Y.1731 Local MEP Linktrace session table.
1.3.6.1.4.1.664.5.75.2.1.3.6.2.1.1ColumnadGenY1731LocalMepLtmTransactionIdnot-accessiblecurrentTransaction identifier value in LTM transmitted for this Linktrace session.
1.3.6.1.4.1.664.5.75.2.1.3.6.2.1.2ColumnadGenY1731LocalMepLtmOutread-onlycurrentThe number of LTM transmitted for this Linktrace session.
1.3.6.1.4.1.664.5.75.2.1.3.6.2.1.3ColumnadGenY1731LocalMepLtrInread-onlycurrentThe number of LTRs received for this Linktrace session.
1.3.6.1.4.1.664.5.75.2.1.3.6.2.1.4ColumnadGenY1731LocalMepLtrInvalidInread-onlycurrentThe number of LTRs received and discarded for this Linktrace session due to invalid formatting.
1.3.6.1.4.1.664.5.75.2.1.3.6.2.1.5ColumnadGenY1731LocalMepLtrValidInread-onlycurrentThe number of LTRs received and processed as valid for this Linktrace session.
1.3.6.1.4.1.664.5.75.2.1.3.6.2.1.6ColumnadGenY1731LocalMepLtTimeRemainingread-onlycurrentEach Linktrace sequence will run for a fixed period of time. This counter indicates how much time is remaining. When the counter is 0, there are results in the…
1.3.6.1.4.1.664.5.75.2.1.3.6.3TableadGenY1731LocalMepLtrTablenot-accessiblecurrentThe Y.1731 Local MEP Linktrace reply table. This table contains a list of Linktrace replies received by a specific MEP in response to a Linktrace message.
1.3.6.1.4.1.664.5.75.2.1.3.6.3.1RowadGenY1731LocalMepLtrEntrynot-accessiblecurrentAn entry in the Y.1731 Local MEP Linktrace reply table.
1.3.6.1.4.1.664.5.75.2.1.3.6.3.1.1ColumnadGenY1731LocalMepLtrTransactionIdnot-accessiblecurrentTransaction identifier returned by a previous transmit Linktrace message command, indicating which LTM's response is going to be returned.
1.3.6.1.4.1.664.5.75.2.1.3.6.3.1.2ColumnadGenY1731LocalMepLtrReceiveOrdernot-accessiblecurrentAn index to distinguish among multiple LTRs with the same LTR Transaction Identifier field value. adGenY1731LocalMepLtrReceiveOrder are assigned sequentially f…
1.3.6.1.4.1.664.5.75.2.1.3.6.3.1.3ColumnadGenY1731LocalMepLtrTtlread-onlycurrentTTL field value for a returned LTR.
1.3.6.1.4.1.664.5.75.2.1.3.6.3.1.4ColumnadGenY1731LocalMepLtrForwardedread-onlycurrentIndicates if a LTM was forwarded by the responding MP, as returned in the 'FwdYes' flag of the flags field.
1.3.6.1.4.1.664.5.75.2.1.3.6.3.1.5ColumnadGenY1731LocalMepLtrTerminalMepread-onlycurrentA boolean value stating whether the forwarded LTM reached a MEP within the MEG, as returned in the Terminal MEP flag of the Flags field.
1.3.6.1.4.1.664.5.75.2.1.3.6.3.1.6ColumnadGenY1731LocalMepLtrLastEgressIdentifierread-onlycurrentAn octet field holding the Last Egress Identifier returned in the LTR Egress Identifier TLV of the LTR. The Last Egress Identifier identifies the MEP Linktrace…
1.3.6.1.4.1.664.5.75.2.1.3.6.3.1.7ColumnadGenY1731LocalMepLtrNextEgressIdentifierread-onlycurrentAn octet field holding the Next Egress Identifier returned in the LTR Egress Identifier TLV of the LTR. The Next Egress Identifier Identifies the Linktrace Res…
1.3.6.1.4.1.664.5.75.2.1.3.6.3.1.8ColumnadGenY1731LocalMepLtrRelayread-onlycurrentValue returned in the Relay Action field.
1.3.6.1.4.1.664.5.75.2.1.3.6.3.1.9ColumnadGenY1731LocalMepLtrChassisIdSubtyperead-onlycurrentThis object specifies the format of the Chassis ID returned in the Sender ID TLV of the LTR, if any.
1.3.6.1.4.1.664.5.75.2.1.3.6.3.1.10ColumnadGenY1731LocalMepLtrChassisIdread-onlycurrentThe Chassis ID returned in the Sender ID TLV of the LTR, if any. The format of this object is determined by the value of the adGenY1731LocalMepLtrChassisIdSubt…
1.3.6.1.4.1.664.5.75.2.1.3.6.3.1.11ColumnadGenY1731LocalMepLtrManAddressDomainread-onlycurrentThe TDomain that identifies the type and format of the related adGenY1731LocalMepLtrManAddress object, used to access the SNMP agent of the system transmitting…
1.3.6.1.4.1.664.5.75.2.1.3.6.3.1.12ColumnadGenY1731LocalMepLtrManAddressread-onlycurrentThe TAddress that can be used to access the SNMP agent of the system transmitting the CCM, received in the CCM Sender ID TLV from that system. If the related o…
1.3.6.1.4.1.664.5.75.2.1.3.6.3.1.13ColumnadGenY1731LocalMepLtrIngressread-onlycurrentThe value returned in the Ingress Action Field of the LTM. The value ingNoTlv(0) indicates that no Reply Ingress TLV was returned in the LTM.
1.3.6.1.4.1.664.5.75.2.1.3.6.3.1.14ColumnadGenY1731LocalMepLtrIngressMacread-onlycurrentMAC address returned in the ingress MAC address field. If the adGenY1731LocalMepLtrIngress object contains the value ingNoTlv(0), then the contents of this obj…
1.3.6.1.4.1.664.5.75.2.1.3.6.3.1.15ColumnadGenY1731LocalMepLtrIngressPortIdSubtyperead-onlycurrentFormat of the Ingress Port ID. If the adGenY1731LocalMepLtrIngress object contains the value ingNoTlv(0), then the contents of this object are meaningless.
1.3.6.1.4.1.664.5.75.2.1.3.6.3.1.16ColumnadGenY1731LocalMepLtrIngressPortIdread-onlycurrentIngress Port ID. The format of this object is determined by the value of the adGenY1731LocalMepLtrIngressPortIdSubtype object. If the adGenY1731LocalMepLtrIngr…
1.3.6.1.4.1.664.5.75.2.1.3.6.3.1.17ColumnadGenY1731LocalMepLtrEgressread-onlycurrentThe value returned in the Egress Action Field of the LTR. The value egrNoTlv(0) indicates that no Reply Egress TLV was returned in the LTR.
1.3.6.1.4.1.664.5.75.2.1.3.6.3.1.18ColumnadGenY1731LocalMepLtrEgressMacread-onlycurrentMAC address returned in the egress MAC address field. If the adGenY1731LocalMepLtrIngress object contains the value egrNoTlv(0), then the contents of this obje…
1.3.6.1.4.1.664.5.75.2.1.3.6.3.1.19ColumnadGenY1731LocalMepLtrEgressPortIdSubtyperead-onlycurrentFormat of the egress Port ID. If the adGenY1731LocalMepLtrEgress object contains the value egrNoTlv(0), then the contents of this object are meaningless.
1.3.6.1.4.1.664.5.75.2.1.3.6.3.1.20ColumnadGenY1731LocalMepLtrEgressPortIdread-onlycurrentEgress Port ID. The format of this object is determined by the value of the adGenY1731LocalMepLtrEgressPortIdSubtype object. If the adGenY1731LocalMepLtrEgress…
1.3.6.1.4.1.664.5.75.2.1.3.6.3.1.21ColumnadGenY1731LocalMepLtrOrganizationSpecificTlvread-onlycurrentAll Organization specific TLVs returned in the LTR, if any. Includes all octets including and following the TLV Length field of each TLV, concatenated together.
1.3.6.1.4.1.664.5.75.2.1.3.6.4TableadGenY1731LocalMepLtmResponderTablenot-accessiblecurrentThe Y.1731 Local MEP Linktrace Responder table. This table contains the counters associated with each Local MEP's Linktrace Responder.
1.3.6.1.4.1.664.5.75.2.1.3.6.4.1RowadGenY1731LocalMepLtmResponderEntrynot-accessiblecurrentAn entry in the Y.1731 Local MEP Linktrace Responder table.
1.3.6.1.4.1.664.5.75.2.1.3.6.4.1.1ColumnadGenY1731LocalMepLtmInread-onlycurrentThe total number of valid LTMs received.
1.3.6.1.4.1.664.5.75.2.1.3.6.4.1.2ColumnadGenY1731LocalMepLtmDiscardedInvalidFormatread-onlycurrentThe total number LTMs discarded due to invalid format.
1.3.6.1.4.1.664.5.75.2.1.3.6.4.1.3ColumnadGenY1731LocalMepLtmDiscardedTtlread-onlycurrentThe total number of LTMs discarded due to invalid Ttl.
1.3.6.1.4.1.664.5.75.2.1.3.6.4.1.4ColumnadGenY1731LocalMepLtmDiscardedTargetMacread-onlycurrentThe total number of LTMs discarded due to invalid target MAC address.
1.3.6.1.4.1.664.5.75.2.1.3.6.4.1.5ColumnadGenY1731LocalMepLtrOutread-onlycurrentThe total number of LTRs transmitted.
1.3.6.1.4.1.664.5.75.2.1.3.7NodeadGenY1731LocalMepOneDm
1.3.6.1.4.1.664.5.75.2.1.3.7.1NodeadGenY1731OneDmScalars
1.3.6.1.4.1.664.5.75.2.1.3.7.1.1ScalaradGenY1731OneDmSessionMaxNumberread-onlycurrentA systemwide value representing the maximum number of one-way frame delay (ETH-1DM) sessions that can be created across all local MEPs on the device.
1.3.6.1.4.1.664.5.75.2.1.3.7.1.2ScalaradGenY1731OneDmSessionCurrentNumberread-onlycurrentCurrent number of 1DM sessions created.
1.3.6.1.4.1.664.5.75.2.1.3.7.1.3ScalaradGenY1731OneDmSessionLastCreateErrorread-onlycurrentThe reason for the last error that occurred while attempting to create an 1DM Session Transmit entry (adGenY1731OneDmSessionTransmitEntry).
1.3.6.1.4.1.664.5.75.2.1.3.7.2TableadGenY1731OneDmSessionTransmitTablenot-accessiblecurrentThe one-way frame-delay (ETH-1DM) session table for a given local MEP. A local MEP's 1DM sessions can be created, edited, and deleted using this table. A local…
1.3.6.1.4.1.664.5.75.2.1.3.7.2.1RowadGenY1731OneDmSessionTransmitEntrynot-accessiblecurrentA one-way frame-delay (1DM) performance monitoring session of a local MEP. A 1DM PM session is unique based on target identifier and VLAN priority. The target …
1.3.6.1.4.1.664.5.75.2.1.3.7.2.1.1ColumnadGenY1731OneDmSessionTargetRmepIdOrMacAddressnot-accessiblecurrentIndicates whether the target specified is a MEPID or a unicast MAC Address. If the target specified is a MEPID, the local MEP will not be able to initiate the …
1.3.6.1.4.1.664.5.75.2.1.3.7.2.1.2ColumnadGenY1731OneDmSessionTargetnot-accessiblecurrentOctet string defining the target for the 1DM session. If adGenY1731OneDmSessionTargetRmepIdOrMacAddress indicates the target is a MEPID then the octet string s…
1.3.6.1.4.1.664.5.75.2.1.3.7.2.1.3ColumnadGenY1731OneDmSessionVlanPrioritynot-accessiblecurrentVLAN Priority that will be used in all 1DM frames sent by this 1DM transmit session.
1.3.6.1.4.1.664.5.75.2.1.3.7.2.1.4ColumnadGenY1731OneDmSessionTargetRemoteMepIdentifierread-onlycurrentTarget MEPID for this 1DM session
1.3.6.1.4.1.664.5.75.2.1.3.7.2.1.5ColumnadGenY1731OneDmSessionTargetMacAddressread-onlycurrentTarget MAC address for this 1DM session
1.3.6.1.4.1.664.5.75.2.1.3.7.2.1.6ColumnadGenY1731OneDmSessionRowStatusread-createcurrentThis OID is used to create/delete a transmit 1DM session of a Local MEP. The only supported settings are createAndGo, createAndWait, and destroy.
1.3.6.1.4.1.664.5.75.2.1.3.7.2.1.7ColumnadGenY1731OneDmSessionAdminStateread-createcurrentThe administrative state of the 1DM transmit session. True indicates that the 1DM session is to function normally and actively transmit 1DMs towards the specif…
1.3.6.1.4.1.664.5.75.2.1.3.7.2.1.8ColumnadGenY1731OneDmSessionStatusread-onlycurrentOperational status of the 1DM transmit session. The minimum attributes that need to be set before a MEP can transmit 1DMs towards the target are: Target MEPID …
1.3.6.1.4.1.664.5.75.2.1.3.7.2.1.9ColumnadGenY1731OneDmSessionStatusStringread-onlycurrentOperational status string of the 1DM transmit session. If the session is expected to be active but is not able to be due to a provisioning issue or conflict, t…
1.3.6.1.4.1.664.5.75.2.1.3.7.2.1.10ColumnadGenY1731OneDmSessionInterframeDelayread-createcurrentAmount of time in milliseconds between 1DM transmissions. The supported range is 100 - 10,000 ms and the default value is 1000 ms.
1.3.6.1.4.1.664.5.75.2.1.3.7.2.1.11ColumnadGenY1731OneDmSessionSizeread-createcurrentSize of the 1DM in bytes. The size encompasses the entire Ethernet frame from the header through the FCS. The supported values are: 0 to indicate Data TLV shou…
1.3.6.1.4.1.664.5.75.2.1.3.7.2.1.12ColumnadGenY1731OneDmSessionDataread-createcurrentData pattern to be used when padding is required to meet the size setting. The default value is 0x00 0x00.
1.3.6.1.4.1.664.5.75.2.1.3.7.3TableadGenY1731OneDmSessionReceiveTablenot-accessiblecurrentThe one-way frame-delay (ETH-1DM) receive table for a given local MEP. The local MEP's 1DM receive attributes can be edited using this table. These settings ar…
1.3.6.1.4.1.664.5.75.2.1.3.7.3.1RowadGenY1731OneDmSessionReceiveEntrynot-accessiblecurrentThe one-way frame-delay (1DM) performance monitoring session receive attributes of a local MEP.
1.3.6.1.4.1.664.5.75.2.1.3.7.3.1.1ColumnadGenY1731OneDmSessionMeasurementIntervalread-createcurrentInterval in seconds over which statistics are generated for received one-way frame delay sessions. The supported range is 60 - 900 seconds and the default valu…
1.3.6.1.4.1.664.5.75.2.1.3.7.3.1.2ColumnadGenY1731OneDmSessionBulkDataExportFileTypesread-createcurrentDetermines which, if any, files are generated by one-way frame delays calculated from received 1DM frames. The files are used to store one-way frame-delay stat…
1.3.6.1.4.1.664.5.75.2.1.3.8NodeadGenY1731LocalMepSlm
1.3.6.1.4.1.664.5.75.2.1.3.8.1NodeadGenY1731SlmScalars
1.3.6.1.4.1.664.5.75.2.1.3.8.1.1ScalaradGenY1731SlmSessionMaxNumberread-onlycurrentA systemwide value representing the maximum number of SLM sessions that can be created across all local MEPs on the device.
1.3.6.1.4.1.664.5.75.2.1.3.8.1.2ScalaradGenY1731SlmSessionCurrentNumberread-onlycurrentCurrent number of SLM sessions created.
1.3.6.1.4.1.664.5.75.2.1.3.8.1.3ScalaradGenY1731SlmSessionLastCreateErrorread-onlycurrentThe reason for the last error that occurred while attempting to create an SLM Session Transmit entry (adGenY1731SlmSessionTransmitEntry).
1.3.6.1.4.1.664.5.75.2.1.3.8.2TableadGenY1731SlmSessionTransmitTablenot-accessiblecurrentThe synthetic single-ended frame-loss (SLM) session table for a given local MEP. The main difference between synthetic frame-loss (ETH-SLM) and normal frame-lo…
1.3.6.1.4.1.664.5.75.2.1.3.8.2.1RowadGenY1731SlmSessionTransmitEntrynot-accessiblecurrentA synthetic single-ended frame-loss (SLM) performance monitoring session of a local MEP. A SLM PM session is unique based on target identifier and VLAN priorit…
1.3.6.1.4.1.664.5.75.2.1.3.8.2.1.1ColumnadGenY1731SlmSessionTargetRmepIdOrMacAddressnot-accessiblecurrentIndicates whether the target specified is a MEPID or a unicast MAC Address. If the target specified is a MEPID the local MEP will not be able to initiate the S…
1.3.6.1.4.1.664.5.75.2.1.3.8.2.1.2ColumnadGenY1731SlmSessionTargetnot-accessiblecurrentOctet string defining the target for the SLM session. If adGenY1731SlmSessionTargetRmepIdOrMacAddress indicates the target is a MEPID then the octet string sho…
1.3.6.1.4.1.664.5.75.2.1.3.8.2.1.3ColumnadGenY1731SlmSessionVlanPrioritynot-accessiblecurrentVLAN Priority that will be used in all SLM frames sent by this SLM transmit session.
1.3.6.1.4.1.664.5.75.2.1.3.8.2.1.4ColumnadGenY1731SlmSessionTargetRemoteMepIdentifierread-onlycurrentTarget MEPID for this SLM session
1.3.6.1.4.1.664.5.75.2.1.3.8.2.1.5ColumnadGenY1731SlmSessionTargetMacAddressread-onlycurrentTarget MAC address for this SLM session
1.3.6.1.4.1.664.5.75.2.1.3.8.2.1.6ColumnadGenY1731SlmSessionRowStatusread-createcurrentThis OID is used to create/delete a transmit SLM session of a Local MEP. The only supported settings are createAndGo, createAndWait, and destroy.
1.3.6.1.4.1.664.5.75.2.1.3.8.2.1.7ColumnadGenY1731SlmSessionAdminStateread-createcurrentThe administrative state of the SLM transmit session. True indicates that the SLM session is to function normally and actively transmit SLMs towards the specif…
1.3.6.1.4.1.664.5.75.2.1.3.8.2.1.8ColumnadGenY1731SlmSessionStatusread-onlycurrentOperational status of the SLM transmit session. The minimum attributes that need to be set before a MEP can transmit SLMs towards the target are: Target MEPID …
1.3.6.1.4.1.664.5.75.2.1.3.8.2.1.9ColumnadGenY1731SlmSessionStatusStringread-onlycurrentOperational status string of the SLM transmit session. If the session is expected to be active but is not able to be due to a provisioning issue or conflict, t…
1.3.6.1.4.1.664.5.75.2.1.3.8.2.1.10ColumnadGenY1731SlmSessionInterframeDelayread-createcurrentAmount of time in milliseconds between SLM transmissions. The supported range is 100 - 10,000 ms and the default value is 1000 ms.
1.3.6.1.4.1.664.5.75.2.1.3.8.2.1.11ColumnadGenY1731SlmSessionMeasurementIntervalread-createcurrentInterval in seconds over which statistics are generated. The supported range is 60 - 900 seconds and the default value is 60. The statistics calculated for a m…
1.3.6.1.4.1.664.5.75.2.1.3.8.2.1.12ColumnadGenY1731SlmSessionSizeread-createcurrentSize of the SLM in bytes. The size encompasses the entire Ethernet frame from the header through the FCS. The supported values are: 0 to indicate Data TLV shou…
1.3.6.1.4.1.664.5.75.2.1.3.8.2.1.13ColumnadGenY1731SlmSessionDataread-createcurrentData pattern to be used when padding is required to meet the size setting. The default value is 0x00 0x00.
1.3.6.1.4.1.664.5.75.2.1.3.8.2.1.14ColumnadGenY1731SlmSessionBulkDataExportFileTypesread-createcurrentDetermines which, if any, files are generated by this SLM transmit session. The files are used to store synthetic single-ended frame-loss statistics. The avera…
1.3.6.1.4.1.664.5.75.2.1.3.9NodeadGenY1731LocalMepClm
1.3.6.1.4.1.664.5.75.2.1.3.9.1TableadGenY1731ClmReceiverTablenot-accessiblecurrentA local MEP can be provisioned to calculate near-end frame-loss between it and a known RMEP by monitoring sequence numbers in received CCMs. This method is ref…
1.3.6.1.4.1.664.5.75.2.1.3.9.1.1RowadGenY1731ClmReceiverEntrynot-accessiblecurrentThe receive properties for a local MEP's CLM function. The properties are unique to a local MEP.
1.3.6.1.4.1.664.5.75.2.1.3.9.1.1.1ColumnadGenY1731ClmReceiverEnabledread-writecurrentConfigures the administrative state of the local MEP's ETH-CLM function. If the ETH-CLM function is enabled, the MEP will monitor the sequence-numbers in CCMs …
1.3.6.1.4.1.664.5.75.2.1.3.9.1.1.2ColumnadGenY1731ClmReceiverMeasurementIntervalread-writecurrentInterval in seconds over which statistics are generated. The supported range is 60 - 900 seconds and the default value is 60. The statistics calculated for a m…
1.3.6.1.4.1.664.5.75.2.1.3.9.1.1.3ColumnadGenY1731ClmReceiverBulkDataExportFileTypesread-writecurrentDetermines which, if any, files are generated by this local MEP's CLM function. The files are used to store near-end frame-loss statistics calculated by the lo…
1.3.6.1.4.1.664.5.75.2.1.4NodeadGenY1731Events
1.3.6.1.4.1.664.5.75.2.1.4.0NodeadGenY1731Traps
1.3.6.1.4.1.664.5.75.2.1.4.0.1NotificationadGenY1731PMFlashFilesClearcurrentThis trap indicates all current and stored bulk PM files have been successfully exported to the server.
1.3.6.1.4.1.664.5.75.2.1.4.0.2NotificationadGenY1731PMFlashFilesSetcurrentThis trap indicates that the Y1731 PM File transferred to flash because bulk data export transfer failed.
1.3.6.1.4.1.664.6.10000.75.2.1IdentityadGenY1731MIBThis MIB defines the objects for the Y.1731 MIB.