MIB Viewer

s412-MIB

247 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.3052Nodeasentria
1.3.6.1.4.1.3052.41Nodes412
1.3.6.1.4.1.3052.41.1Nodedevice
1.3.6.1.4.1.3052.41.1.1ScalarserialNumberread-onlymandatory8-character serial number
1.3.6.1.4.1.3052.41.1.2ScalarfirmwareVersionread-onlymandatoryFirmware version text string
1.3.6.1.4.1.3052.41.1.3ScalarsiteIDread-writemandatorySite Identifier, up to 12 characters.
1.3.6.1.4.1.3052.41.1.4ScalarsnmpManagerread-writedeprecatedThis is snmp manager #1
1.3.6.1.4.1.3052.41.1.6ScalarforceTrapsread-writemandatoryAny write non-zero forces set of traps to be send to the SNMP Manager
1.3.6.1.4.1.3052.41.1.7ScalarthisTrapTextread-writemandatoryA text string included in all traps
1.3.6.1.4.1.3052.41.1.8ScalaralarmStatusread-onlymandatoryA text status of all alarms
1.3.6.1.4.1.3052.41.1.9ScalarsnmpManager1read-writemandatorySNMP manager #1
1.3.6.1.4.1.3052.41.1.10ScalarsnmpManager2read-writemandatorySNMP manager #2
1.3.6.1.4.1.3052.41.1.11ScalarsnmpManager3read-writemandatorySNMP manager #3
1.3.6.1.4.1.3052.41.1.12ScalarsnmpManager4read-writemandatorySNMP manager #4
1.3.6.1.4.1.3052.41.1.13ScalarstatusRepeatHoursread-writemandatory0=none, 1-24 Number of Hours between Status Traps being Sent
1.3.6.1.4.1.3052.41.1.14ScalarserialTimeoutread-writemandatory5-30, Minutes of non-activity timeout on serial setup
1.3.6.1.4.1.3052.41.1.15ScalarpowerupTrapsendread-writemandatory0-no, 1-yes, send traps for all sensors on powerup
1.3.6.1.4.1.3052.41.1.16ScalarnetlossTrapsendread-writemandatory0-no, 1-yes, send traps for detected netloss and back up
1.3.6.1.4.1.3052.41.1.17ScalarbuildIDread-onlymandatory5-chars max text for build identifier
1.3.6.1.4.1.3052.41.2Nodecontacts
1.3.6.1.4.1.3052.41.2.1Nodecontact1
1.3.6.1.4.1.3052.41.2.1.1Scalarcontact1Nameread-writemandatoryName for contact, up to 30 characters
1.3.6.1.4.1.3052.41.2.1.2Scalarcontact1Stateread-onlymandatoryCurrent State of Contact, 0-open 1-closed
1.3.6.1.4.1.3052.41.2.1.3Scalarcontact1AlarmEnableread-writemandatory0-alarms disabled 1-alarms enabled
1.3.6.1.4.1.3052.41.2.1.4Scalarcontact1ActiveDirectionread-writemandatory0-alarm on open 1-alarm on closed
1.3.6.1.4.1.3052.41.2.1.5Scalarcontact1Thresholdread-writemandatoryNumber of seconds that the contact must remain in a state before generating a trap, range 0-255
1.3.6.1.4.1.3052.41.2.1.6Scalarcontact1ReturnNormalTrapread-writemandatory0-return to normal traps not sent, 1-sent
1.3.6.1.4.1.3052.41.2.1.7Scalarcontact1TrapRepeatread-writemandatory0-no repeats. 1-255 number of minutes between repeats of alarm traps.
1.3.6.1.4.1.3052.41.2.1.8Scalarcontact1Severityread-writemandatory1-minor 2-major 3-critical 4-severe 5-warning
1.3.6.1.4.1.3052.41.2.2Nodecontact2
1.3.6.1.4.1.3052.41.2.2.1Scalarcontact2Nameread-writemandatoryName for contact, up to 30 characters
1.3.6.1.4.1.3052.41.2.2.2Scalarcontact2Stateread-onlymandatoryCurrent State of Contact, 0-open 1-closed
1.3.6.1.4.1.3052.41.2.2.3Scalarcontact2AlarmEnableread-writemandatory0-no alarms 1-alarms enabled
1.3.6.1.4.1.3052.41.2.2.4Scalarcontact2ActiveDirectionread-writemandatory0-alarm on open 1-alarm on closed
1.3.6.1.4.1.3052.41.2.2.5Scalarcontact2Thresholdread-writemandatoryNumber of seconds must be in a state to be 'open' or 'closed'
1.3.6.1.4.1.3052.41.2.2.6Scalarcontact2ReturnNormalTrapread-writemandatory0-not sent, 1-sent
1.3.6.1.4.1.3052.41.2.2.7Scalarcontact2TrapRepeatread-writemandatory0-no repeats. 1-255 number of minutes between repeats of alarm traps
1.3.6.1.4.1.3052.41.2.2.8Scalarcontact2Severityread-writemandatory1-minor 2-major 3-critical 4-severe 5-warning
1.3.6.1.4.1.3052.41.2.3Nodecontact3
1.3.6.1.4.1.3052.41.2.3.1Scalarcontact3Nameread-writemandatoryName for contact, up to 30 characters
1.3.6.1.4.1.3052.41.2.3.2Scalarcontact3Stateread-onlymandatoryCurrent State of Contact, 0-open 1-closed
1.3.6.1.4.1.3052.41.2.3.3Scalarcontact3AlarmEnableread-writemandatory0-no alarms 1-alarms enabled
1.3.6.1.4.1.3052.41.2.3.4Scalarcontact3ActiveDirectionread-writemandatory0-alarm on open 1-alarm on closed
1.3.6.1.4.1.3052.41.2.3.5Scalarcontact3Thresholdread-writemandatoryNumber of seconds must be in a state to be 'open' or 'closed'
1.3.6.1.4.1.3052.41.2.3.6Scalarcontact3ReturnNormalTrapread-writemandatory0-not sent, 1-sent
1.3.6.1.4.1.3052.41.2.3.7Scalarcontact3TrapRepeatread-writemandatory0-no repeats. 1-255 number of minutes between repeats of alarm traps
1.3.6.1.4.1.3052.41.2.3.8Scalarcontact3Severityread-writemandatory1-minor 2-major 3-critical 4-severe 5-warning
1.3.6.1.4.1.3052.41.2.4Nodecontact4
1.3.6.1.4.1.3052.41.2.4.1Scalarcontact4Nameread-writemandatoryName for contact, up to 30 characters
1.3.6.1.4.1.3052.41.2.4.2Scalarcontact4Stateread-onlymandatoryCurrent State of Contact, 0-open 1-closed
1.3.6.1.4.1.3052.41.2.4.3Scalarcontact4AlarmEnableread-writemandatory0-no alarms 1-alarms enabled
1.3.6.1.4.1.3052.41.2.4.4Scalarcontact4ActiveDirectionread-writemandatory0-alarm on open 1-alarm on closed
1.3.6.1.4.1.3052.41.2.4.5Scalarcontact4Thresholdread-writemandatoryNumber of seconds must be in a state to be 'open' or 'closed'
1.3.6.1.4.1.3052.41.2.4.6Scalarcontact4ReturnNormalTrapread-writemandatory0-not sent, 1-sent
1.3.6.1.4.1.3052.41.2.4.7Scalarcontact4TrapRepeatread-writemandatory0-no repeats. 1-255 number of minutes between repeats of alarm traps
1.3.6.1.4.1.3052.41.2.4.8Scalarcontact4Severityread-writemandatory1-minor 2-major 3-critical 4-severe 5-warning
1.3.6.1.4.1.3052.41.2.5Nodecontact5
1.3.6.1.4.1.3052.41.2.5.1Scalarcontact5Nameread-writemandatoryName for contact, up to 30 characters
1.3.6.1.4.1.3052.41.2.5.2Scalarcontact5Stateread-onlymandatoryCurrent State of Contact, 0-open 1-closed
1.3.6.1.4.1.3052.41.2.5.3Scalarcontact5AlarmEnableread-writemandatory0-no alarms 1-alarms enabled
1.3.6.1.4.1.3052.41.2.5.4Scalarcontact5ActiveDirectionread-writemandatory0-alarm on open 1-alarm on closed
1.3.6.1.4.1.3052.41.2.5.5Scalarcontact5Thresholdread-writemandatoryNumber of seconds must be in a state to be 'open' or 'closed'
1.3.6.1.4.1.3052.41.2.5.6Scalarcontact5ReturnNormalTrapread-writemandatory0-not sent, 1-sent
1.3.6.1.4.1.3052.41.2.5.7Scalarcontact5TrapRepeatread-writemandatory0-no repeats. 1-255 number of minutes between repeats of alarm traps
1.3.6.1.4.1.3052.41.2.5.8Scalarcontact5Severityread-writemandatory1-minor 2-major 3-critical 4-severe 5-warning
1.3.6.1.4.1.3052.41.2.6Nodecontact6
1.3.6.1.4.1.3052.41.2.6.1Scalarcontact6Nameread-writemandatoryName for contact, up to 30 characters
1.3.6.1.4.1.3052.41.2.6.2Scalarcontact6Stateread-onlymandatoryCurrent State of Contact, 0-open 1-closed
1.3.6.1.4.1.3052.41.2.6.3Scalarcontact6AlarmEnableread-writemandatory0-no alarms 1-alarms enabled
1.3.6.1.4.1.3052.41.2.6.4Scalarcontact6ActiveDirectionread-writemandatory0-alarm on open 1-alarm on closed
1.3.6.1.4.1.3052.41.2.6.5Scalarcontact6Thresholdread-writemandatoryNumber of seconds must be in a state to be 'open' or 'closed'
1.3.6.1.4.1.3052.41.2.6.6Scalarcontact6ReturnNormalTrapread-writemandatory0-not sent, 1-sent
1.3.6.1.4.1.3052.41.2.6.7Scalarcontact6TrapRepeatread-writemandatory0-no repeats. 1-255 number of minutes between repeats of alarm traps.
1.3.6.1.4.1.3052.41.2.6.8Scalarcontact6Severityread-writemandatory1-minor 2-major 3-critical 4-severe 5-warning
1.3.6.1.4.1.3052.41.3Noderelays
1.3.6.1.4.1.3052.41.3.1Noderelay1
1.3.6.1.4.1.3052.41.3.1.1Scalarrelay1Nameread-writemandatoryName for relay, up to 30 characters
1.3.6.1.4.1.3052.41.3.1.2Scalarrelay1CurrentStateread-writemandatory0-opened, 1-closed
1.3.6.1.4.1.3052.41.3.1.3Scalarrelay1PowerupStateread-writemandatory0-opened, 1-closed
1.3.6.1.4.1.3052.41.3.2Noderelay2
1.3.6.1.4.1.3052.41.3.2.1Scalarrelay2Nameread-writemandatoryName for relay, up to 30 characters
1.3.6.1.4.1.3052.41.3.2.2Scalarrelay2CurrentStateread-writemandatory0-opened, 1-closed
1.3.6.1.4.1.3052.41.3.2.3Scalarrelay2PowerupStateread-writemandatory0-opened, 1-closed
1.3.6.1.4.1.3052.41.4Nodetempsensor
1.3.6.1.4.1.3052.41.4.1ScalartempValueread-onlymandatoryCurrent Temperature Value, in C or F based on 1.3.6.1.4.1.3052.41.4.10
1.3.6.1.4.1.3052.41.4.2ScalartempAlarmEnableread-writemandatory0=alarms disabled, 1=alarms enabled
1.3.6.1.4.1.3052.41.4.3ScalartempHighLevelread-writemandatoryLevel at which the High alarm goes active
1.3.6.1.4.1.3052.41.4.4ScalartempVeryHighLevelread-writemandatoryLevel at which the Very High alarm goes active
1.3.6.1.4.1.3052.41.4.5ScalartempLowLevelread-writemandatoryLevel at which the Low alarm goes active
1.3.6.1.4.1.3052.41.4.6ScalartempVeryLowLevelread-writemandatoryLevel at which the Very Low alarm goes active
1.3.6.1.4.1.3052.41.4.7ScalartempAlarmThresholdread-writemandatorySeconds must be in a range to be an alarm
1.3.6.1.4.1.3052.41.4.8ScalartempReturnNormalTrapread-writemandatory0-not sent, 1-send trap on return to normal range
1.3.6.1.4.1.3052.41.4.9ScalartempTrapRepeatread-writemandatory0-no repeats. 1-255 number of minutes between repeats of alarm traps.
1.3.6.1.4.1.3052.41.4.10ScalartempModeread-writemandatory0=all temp readings and levels in degrees F, 1=in degrees C
1.3.6.1.4.1.3052.41.4.11ScalartempHighSeverityread-writemandatoryHigh Level Severity 1-minor 2-major 3-critical 4-severe 5-warning
1.3.6.1.4.1.3052.41.4.12ScalartempVeryHighSeverityread-writemandatoryVery High Level Severity 1-minor 2-major 3-critical 4-severe 5-warning
1.3.6.1.4.1.3052.41.4.13ScalartempLowSeverityread-writemandatoryLow Level Severity 1-minor 2-major 3-critical 4-severe 5-warning
1.3.6.1.4.1.3052.41.4.14ScalartempVeryLowSeverityread-writemandatoryVery Low Level Severity 1-minor 2-major 3-critical 4-severe 5-warning
1.3.6.1.4.1.3052.41.4.15ScalartempNameread-writemandatoryName for temperature sensor, up to 30 characters
1.3.6.1.4.1.3052.41.5Nodehumiditysensor
1.3.6.1.4.1.3052.41.5.1ScalarhumidityValueread-onlymandatoryCurrent Relative Humidity Value (0-100%)
1.3.6.1.4.1.3052.41.5.2ScalarhumidityAlarmEnableread-writemandatory0=alarms disabled, 1=alarms enabled
1.3.6.1.4.1.3052.41.5.3ScalarhumidityHighLevelread-writemandatoryLevel at which the High alarm goes active
1.3.6.1.4.1.3052.41.5.4ScalarhumidityVeryHighLevelread-writemandatoryLevel at which the Very High alarm goes active
1.3.6.1.4.1.3052.41.5.5ScalarhumidityLowLevelread-writemandatoryLevel at which the Low alarm goes active
1.3.6.1.4.1.3052.41.5.6ScalarhumidityVeryLowLevelread-writemandatoryLevel at which the Very Low alarm goes active
1.3.6.1.4.1.3052.41.5.7ScalarhumidityAlarmThresholdread-writemandatorySeconds must be in a range to be an alarm
1.3.6.1.4.1.3052.41.5.8ScalarhumidityReturnNormalTrapread-writemandatory0-not sent, 1-send trap on return to normal range
1.3.6.1.4.1.3052.41.5.9ScalarhumidityTrapRepeatread-writemandatory0-no repeats. 1-255 number of minutes between repeats of alarm traps.
1.3.6.1.4.1.3052.41.5.10ScalarhumidityHighSeverityread-writemandatoryHigh Level Severity 1-minor 2-major 3-critical 4-severe 5-warning
1.3.6.1.4.1.3052.41.5.11ScalarhumidityVeryHighSeverityread-writemandatoryVery High Level Severity 1-minor 2-major 3-critical 4-severe 5-warning
1.3.6.1.4.1.3052.41.5.12ScalarhumidityLowSeverityread-writemandatoryLow Level Severity 1-minor 2-major 3-critical 4-severe 5-warning
1.3.6.1.4.1.3052.41.5.13ScalarhumidityVeryLowSeverityread-writemandatoryVery Low Level Severity 1-minor 2-major 3-critical 4-severe 5-warning
1.3.6.1.4.1.3052.41.5.14ScalarhumidityNameread-writemandatoryName for humidity sensor, up to 30 characters
1.3.6.1.4.1.3052.41.6Nodepassthrough
1.3.6.1.4.1.3052.41.6.1ScalarptNeedPasswordread-writemandatory0-no 1-yes, is password required for passthrough connection.
1.3.6.1.4.1.3052.41.6.2ScalarptSayLoginTextread-writemandatory0-no 1-yes, is passthrough login text displayed on connection.
1.3.6.1.4.1.3052.41.6.3ScalarptLoginTextread-writemandatory0-24 char string which may be displayed on socket connection. Requires that ptSayLoginText be enabled to display this string.
1.3.6.1.4.1.3052.41.6.4ScalarptSaySiteIDread-writemandatory0-no 1-yes, is SiteID displayed on pass through connection.
1.3.6.1.4.1.3052.41.6.5ScalarptUsernameread-writemandatory0-16 char string for Username used in serial passthrough connections
1.3.6.1.4.1.3052.41.6.6ScalarptPasswordread-writemandatory0-16 char string for Password used in serial passthrough connections
1.3.6.1.4.1.3052.41.6.7ScalarptTimeoutread-writemandatorynumber of minutes (1-255) of idle activity (both directions) which causes disconnect. 0-never
1.3.6.1.4.1.3052.41.6.8ScalarptEscCharread-writemandatoryASCII character code (e.g, Escape=27) which if entered on the tcp port three times in a row causes disconnect. 0-none
1.3.6.1.4.1.3052.41.6.9ScalarptLfstripToPortread-writemandatory0-no 1-yes linefeed characters received on TCP connection are removed from stream to serial port
1.3.6.1.4.1.3052.41.6.10ScalarptLfstripFromPortread-writemandatory0-no 1-yes linefeed characters received on serial port are removed from stream to TCP connection
1.3.6.1.4.1.3052.41.6.11ScalarptSerialBaudrateread-writemandatory300 600 1200 2400 4800 9600 19200 baud are allowed values
1.3.6.1.4.1.3052.41.6.12ScalarptSerialWordlengthread-writemandatory7 or 8 bit word selection
1.3.6.1.4.1.3052.41.6.13ScalarptSerialParityread-writemandatoryN E O are allowed values for parity (none, even, odd) [a single-character string]
1.3.6.1.4.1.3052.41.6.14ScalarptTCPPortnumberread-writemandatoryIP port number for passthrough connection (range 1024-65534)
1.3.6.1.4.1.3052.41.7Nodeftp
1.3.6.1.4.1.3052.41.7.1ScalarftpUsernameread-writemandatory0-16 char string for Username used in ftp server for updates
1.3.6.1.4.1.3052.41.7.2ScalarftpPasswordread-writemandatory0-16 char string for Password used in ftp server for updates
1.3.6.1.4.1.3052.41.8Nodeanalog
1.3.6.1.4.1.3052.41.8.1Nodeanalog1
1.3.6.1.4.1.3052.41.8.1.1Scalaranalog1Valueread-onlymandatoryValue of current analog reading, in 1/100 volt, +- 9999 range
1.3.6.1.4.1.3052.41.8.1.2Scalaranalog1AlarmEnableread-writemandatory0=no alarms, 1=send alarms
1.3.6.1.4.1.3052.41.8.1.3Scalaranalog1HighLevelread-writemandatoryLevel at which the High alarm goes active
1.3.6.1.4.1.3052.41.8.1.4Scalaranalog1VeryHighLevelread-writemandatoryLevel at which the Very High alarm goes active
1.3.6.1.4.1.3052.41.8.1.5Scalaranalog1LowLevelread-writemandatoryLevel at which the Low alarm goes active
1.3.6.1.4.1.3052.41.8.1.6Scalaranalog1VeryLowLevelread-writemandatoryLevel at which the Very Low alarm goes active
1.3.6.1.4.1.3052.41.8.1.7Scalaranalog1AlarmThresholdread-writemandatorySeconds must be in a range to be an alarm
1.3.6.1.4.1.3052.41.8.1.8Scalaranalog1ReturnNormalTrapread-writemandatory0-not sent, 1-send trap on return to normal range
1.3.6.1.4.1.3052.41.8.1.9Scalaranalog1TrapRepeatread-writemandatory0-no repeats else number of minutes between repeats of trap
1.3.6.1.4.1.3052.41.8.1.10Scalaranalog1HighSeverityread-writemandatoryHigh Level Severity 1-minor 2-major 3-critical 4-severe 5-warning
1.3.6.1.4.1.3052.41.8.1.11Scalaranalog1VeryHighSeverityread-writemandatoryVery High Level Severity 1-minor 2-major 3-critical 4-severe 5-warning
1.3.6.1.4.1.3052.41.8.1.12Scalaranalog1LowSeverityread-writemandatoryLow Level Severity 1-minor 2-major 3-critical 4-severe 5-warning
1.3.6.1.4.1.3052.41.8.1.13Scalaranalog1VeryLowSeverityread-writemandatoryVery Low Level Severity 1-minor 2-major 3-critical 4-severe 5-warning
1.3.6.1.4.1.3052.41.8.1.14Scalaranalog1Nameread-writemandatoryName for analog sensor 1, up to 30 characters
1.3.6.1.4.1.3052.41.8.2Nodeanalog2
1.3.6.1.4.1.3052.41.8.2.1Scalaranalog2Valueread-onlymandatoryValue of current analog reading, in 1/100 volt, +- 9999 range
1.3.6.1.4.1.3052.41.8.2.2Scalaranalog2AlarmEnableread-writemandatory0=no alarms, 1=send alarms
1.3.6.1.4.1.3052.41.8.2.3Scalaranalog2HighLevelread-writemandatoryLevel at which the High alarm goes active
1.3.6.1.4.1.3052.41.8.2.4Scalaranalog2VeryHighLevelread-writemandatoryLevel at which the Very High alarm goes active
1.3.6.1.4.1.3052.41.8.2.5Scalaranalog2LowLevelread-writemandatoryLevel at which the Low alarm goes active
1.3.6.1.4.1.3052.41.8.2.6Scalaranalog2VeryLowLevelread-writemandatoryLevel at which the Very Low alarm goes active
1.3.6.1.4.1.3052.41.8.2.7Scalaranalog2AlarmThresholdread-writemandatorySeconds must be in a range to be an alarm
1.3.6.1.4.1.3052.41.8.2.8Scalaranalog2ReturnNormalTrapread-writemandatory0-not sent, 1-send trap on return to normal range
1.3.6.1.4.1.3052.41.8.2.9Scalaranalog2TrapRepeatread-writemandatory0-no repeats else number of minutes between repeats of trap
1.3.6.1.4.1.3052.41.8.2.10Scalaranalog2HighSeverityread-writemandatoryHigh Level Severity 1-minor 2-major 3-critical 4-severe 5-warning
1.3.6.1.4.1.3052.41.8.2.11Scalaranalog2VeryHighSeverityread-writemandatoryVery High Level Severity 1-minor 2-major 3-critical 4-severe 5-warning
1.3.6.1.4.1.3052.41.8.2.12Scalaranalog2LowSeverityread-writemandatoryLow Level Severity 1-minor 2-major 3-critical 4-severe 5-warning
1.3.6.1.4.1.3052.41.8.2.13Scalaranalog2VeryLowSeverityread-writemandatoryVery Low Level Severity 1-minor 2-major 3-critical 4-severe 5-warning
1.3.6.1.4.1.3052.41.8.2.14Scalaranalog2Nameread-writemandatoryName for analog sensor 2, up to 30 characters
1.3.6.1.4.1.3052.41.10NodeeventSensorStatus
1.3.6.1.4.1.3052.41.10.1TableesPointTablenot-accessiblemandatoryThis table organizes 4 basic attributes of points. A point is a particular sensor on an EventSensor (e.g., temperature, humidity, contact closure 2, relay 5, e…
1.3.6.1.4.1.3052.41.10.1.1RowesPointEntrynot-accessiblemandatoryEntry for EventSensor point table
1.3.6.1.4.1.3052.41.10.1.1.1ColumnesIndexESread-onlymandatoryThe part of the point index that refers to an EventSensor. The point index is a string of 3 numbers separated by periods. It contains all the information neces…
1.3.6.1.4.1.3052.41.10.1.1.2ColumnesIndexPCread-onlymandatoryThe part of the point index that refers to point class. The point index is a string of 3 numbers separated by periods. It contains all the information necessar…
1.3.6.1.4.1.3052.41.10.1.1.3ColumnesIndexPointread-onlymandatoryThe part of the point index that delineates which sensor on the EventSensor. So this combined with esIndexPC (Point Class or type) and esIndexES (which EventSe…
1.3.6.1.4.1.3052.41.10.1.1.4ColumnesPointNameread-writemandatoryThe name of the point on an EventSensor. For example, 'AC temp' (in the case of the temperature sensor on an EventSensor). There can be multiple points of the …
1.3.6.1.4.1.3052.41.10.1.1.5ColumnesPointInEventStateread-writemandatoryA number referring to the event state of a point on an EventSensor. This number can have different meanings depending on the point class. If the point class is…
1.3.6.1.4.1.3052.41.10.1.1.6ColumnesPointValueIntread-writemandatoryA number referring to the value of a point on an EventSensor. If the point class is temperature, then this object is the temperature in its configured scale (d…
1.3.6.1.4.1.3052.41.10.1.1.7ColumnesPointValueStrread-onlymandatoryA string referring to the value of a point on an EventSensor. For contact closures and relays this object is either 'Open' or 'Closed'. For temperature and hum…
1.3.6.1.4.1.3052.41.11NodeeventSensorConfig
1.3.6.1.4.1.3052.41.11.1ScalaresNumberEventSensorsread-onlymandatoryThe number of EventSensors recognized by the s412 Range: 0-4
1.3.6.1.4.1.3052.41.11.2TableesTablenot-accessiblemandatoryThe table of what EventSensors are attached to the unit
1.3.6.1.4.1.3052.41.11.2.1RowesEntrynot-accessiblemandatoryTable entry for EventSensor table
1.3.6.1.4.1.3052.41.11.2.1.1ColumnesIndexread-onlymandatoryThis number refers to an EventSensor; it has the same meaning as the esIndexES object (see above), except that this object is used only within the esTable bran…
1.3.6.1.4.1.3052.41.11.2.1.2ColumnesIDread-onlymandatoryThe factory-assigned ID of the EventSensor
1.3.6.1.4.1.3052.41.11.2.1.3ColumnesNumberTempSensorsread-onlymandatoryThe number of temperature sensors on the EventSensor
1.3.6.1.4.1.3052.41.11.2.1.4ColumnesTempReportingModeread-onlymandatoryDescription of how temperature values should be interpreted.
1.3.6.1.4.1.3052.41.11.2.1.5ColumnesNumberCCsread-onlymandatoryThe number of contact closures on the EventSensor.
1.3.6.1.4.1.3052.41.11.2.1.6ColumnesCCReportingModeread-onlymandatoryDescription of how CC values should be interpreted.
1.3.6.1.4.1.3052.41.11.2.1.7ColumnesNumberHumidSensorsread-onlymandatoryThe number of humidity sensors on the EventSensor.
1.3.6.1.4.1.3052.41.11.2.1.8ColumnesHumidReportingModeread-onlymandatoryDescription of how humidity sensor values should be interpreted.
1.3.6.1.4.1.3052.41.11.2.1.13ColumnesNumberAnalogread-onlymandatoryThe number of analog inputs on the EventSensor.
1.3.6.1.4.1.3052.41.11.2.1.14ColumnesAnalogReportingModeread-onlymandatoryDescription of how analog input values should be interpreted.
1.3.6.1.4.1.3052.41.11.2.1.15ColumnesNumberRelayOutputsread-onlymandatoryThe number of relay outputs on the EventSensor
1.3.6.1.4.1.3052.41.11.2.1.16ColumnesRelayReportingModeread-onlymandatoryDescription of how relay output values should be interpreted.
1.3.6.1.4.1.3052.41.99Nodetechsupport
1.3.6.1.4.1.3052.41.99.1ScalartechsupportIPAddressread-writemandatoryMay read or Set IP Address, takes effect on restart
1.3.6.1.4.1.3052.41.99.2ScalartechsupportNetMaskread-writemandatoryMay read or Set NetMask, takes effect on restart
1.3.6.1.4.1.3052.41.99.3ScalartechsupportRouterread-writemandatoryMay read or Set Router IP Address, takes effect on restart
1.3.6.1.4.1.3052.41.99.4ScalartechsupportRestartread-writemandatoryReads as 0, any Write resets unit so new IP, Netmask, Router may be used
1.3.6.1.4.1.3052.41.99.5ScalartechsupportVersionNumberread-writemandatoryVersion Number of Firmware
1.3.6.1.4.1.3052.41.100Nodemibend
1.3.6.1.4.1.3052.41.100.1ScalarmibendObjectread-onlymandatoryAn object after all active mib items, to help some managers compile
1.3.6.1.4.1.3052.41.20001Nodecontact1ActiveTrapSent to show Contact 1 is in the alarm state
1.3.6.1.4.1.3052.41.20002Nodecontact2ActiveTrapSent to show Contact 2 is in the alarm state
1.3.6.1.4.1.3052.41.20003Nodecontact3ActiveTrapSent to show Contact 3 is in the alarm state
1.3.6.1.4.1.3052.41.20004Nodecontact4ActiveTrapSent to show Contact 4 is in the alarm state
1.3.6.1.4.1.3052.41.20005Nodecontact5ActiveTrapSent to show Contact 5 is in the alarm state
1.3.6.1.4.1.3052.41.20006Nodecontact6ActiveTrapSent to show Contact 6 is in the alarm state
1.3.6.1.4.1.3052.41.20010NodetempHighTrapSent to show Temp exceeded High Temp Threshold
1.3.6.1.4.1.3052.41.20011NodetempVeryHighTrapSent to show Temp exceeded Very High Temp Threshold
1.3.6.1.4.1.3052.41.20012NodetempLowTrapSent to show Temp went below Low Temp Threshold
1.3.6.1.4.1.3052.41.20013NodetempVeryLowTrapSent to show Temp went below Very Low Temp Threshold
1.3.6.1.4.1.3052.41.20020NodehumidityHighTrapSent to show humidity exceeded High humidity Threshold
1.3.6.1.4.1.3052.41.20021NodehumidityVeryHighTrapSent to show humidity exceeded Very High humidity Threshold
1.3.6.1.4.1.3052.41.20022NodehumidityLowTrapSent to show humidity went below Low humidity Threshold
1.3.6.1.4.1.3052.41.20023NodehumidityVeryLowTrapSent to show humidity went below Very Low humidity Threshold
1.3.6.1.4.1.3052.41.20030Nodeanalog1HighTrapSent to show analog1 exceeded High analog1 Threshold
1.3.6.1.4.1.3052.41.20031Nodeanalog1VeryHighTrapSent to show analog1 exceeded Very High analog1 Threshold
1.3.6.1.4.1.3052.41.20032Nodeanalog1LowTrapSent to show analog1 went below Low analog1 Threshold
1.3.6.1.4.1.3052.41.20033Nodeanalog1VeryLowTrapSent to show analog1 went below Very Low analog1 Threshold
1.3.6.1.4.1.3052.41.20040Nodeanalog2HighTrapSent to show analog2 exceeded High analog2 Threshold
1.3.6.1.4.1.3052.41.20041Nodeanalog2VeryHighTrapSent to show analog2 exceeded Very High analog2 Threshold
1.3.6.1.4.1.3052.41.20042Nodeanalog2LowTrapSent to show analog2 went below Low analog2 Threshold
1.3.6.1.4.1.3052.41.20043Nodeanalog2VeryLowTrapSent to show analog2 went below Very Low analog2 Threshold
1.3.6.1.4.1.3052.41.20101NodecontactESActiveTrapSent to show EventSensor contact is in the alarm state
1.3.6.1.4.1.3052.41.20110NodetempESHighTrapSent to show Temp exceeded High Threshold on an EventSensor
1.3.6.1.4.1.3052.41.20111NodetempESVeryHighTrapSent to show Temp exceeded Very High Threshold on an EventSensor
1.3.6.1.4.1.3052.41.20112NodetempESLowTrapSent to show Temp went below Low Threshold on an EventSensor
1.3.6.1.4.1.3052.41.20113NodetempESVeryLowTrapSent to show Temp went below Very Low Threshold on an EventSensor
1.3.6.1.4.1.3052.41.20120NodehumidityESHighTrapSent to show humidity exceeded High Threshold on an EventSensor
1.3.6.1.4.1.3052.41.20121NodehumidityESVeryHighTrapSent to show humidity exceeded Very High Threshold on an EventSensor
1.3.6.1.4.1.3052.41.20122NodehumidityESLowTrapSent to show humidity went below Low Threshold on an EventSensor
1.3.6.1.4.1.3052.41.20123NodehumidityESVeryLowTrapSent to show humidity went below Very Low Threshold on an EventSensor
1.3.6.1.4.1.3052.41.20130NodevoltageESHighTrapSent to show voltage exceeded High Threshold on an EventSensor
1.3.6.1.4.1.3052.41.20131NodevoltageESVeryHighTrapSent to show voltage exceeded Very High Threshold on an EventSensor
1.3.6.1.4.1.3052.41.20132NodevoltageESLowTrapSent to show voltage went below Low Threshold on an EventSensor
1.3.6.1.4.1.3052.41.20133NodevoltageESVeryLowTrapSent to show voltage went below Very Low Threshold on an EventSensor
1.3.6.1.4.1.3052.41.21001Nodecontact1NormalTrapSent to show Contact 1 is in the normal state
1.3.6.1.4.1.3052.41.21002Nodecontact2NormalTrapSent to show Contact 2 is in the normal state
1.3.6.1.4.1.3052.41.21003Nodecontact3NormalTrapSent to show Contact 3 is in the normal state
1.3.6.1.4.1.3052.41.21004Nodecontact4NormalTrapSent to show Contact 4 is in the normal state
1.3.6.1.4.1.3052.41.21005Nodecontact5NormalTrapSent to show Contact 5 is in the normal state
1.3.6.1.4.1.3052.41.21006Nodecontact6NormalTrapSent to show Contact 6 is in the normal state
1.3.6.1.4.1.3052.41.21010NodetempNormalTrapSent to show Temp went back to Normal range
1.3.6.1.4.1.3052.41.21020NodehumidityNormalTrapSent to show Humidity went back to Normal range
1.3.6.1.4.1.3052.41.21030Nodeanalog1NormalTrapSent to show analog1 went back to Normal range
1.3.6.1.4.1.3052.41.21040Nodeanalog2NormalTrapSent to show analog2 went back to Normal range
1.3.6.1.4.1.3052.41.21101NodecontactESNormalTrapSend to show EventSensor contact has returned to normal state
1.3.6.1.4.1.3052.41.21110NodetempESNormalTrapSent to show EventSensor Temp went back to Normal range
1.3.6.1.4.1.3052.41.21120NodehumidityESNormalTrapSent to show EventSensor Humidity went back to Normal range
1.3.6.1.4.1.3052.41.21130NodevoltageESNormalTrapSent to show EventSensor voltage went back to Normal range
1.3.6.1.4.1.3052.41.22000NodetestTrapSent for testing the SNMP interface