MIB Viewer

a3IPsecureMaxLevel

OBJECT-TYPE
1.3.6.1.4.1.43.2.12.3.1.8
Access
read-write
Status
mandatory
Sub-identifiers
0
This define the maximum classification level which is acceptable by this port. This applies to any packet which is entering or leaving this port. If the classification level is outside the range defined by the value of this object and the value of a3IPsecureMinLevel, the packet is discarded. If a3IPsecureMinLevel is set to a level greater than the level identified by this object, the value of this object will be shifted so it is equal to a3IPsecureMinLevel.
INTEGER { topSecret (1), secret (2), confidential (3), unclassified (4) }