Sub-identifiers
0
This object is used to configure the packetization period in millisecs for a given codec. The default value of this object depends upon the profile for itu 1 = 5 (Applicable value is only 5) itu 2 = 5 (Applicable value is only 5) itu 3 = 5 (Applicable value is only 5) itu 7 = 10 (Applicable values are 5 & 10) itu 8 = 10 (Applicable values are 5 & 10) itu 12 = 30 (Applicable value is only 30) custom 100 = 10 (Applicable values are 5 & 10) custom 101 = 10 (Applicable values are 5 & 10) custom 110 = 30 (Applicable values are 5,10 & 30) custom 200 = 5 (Applicable value is only 5) custom 201 = 5 (Applicable value is only 5) custom 210 = 20 (Applicable value are only 5, 10 & 20)
INTEGER { five (5), ten (10), twenty (20), thirty(30), fourty (40) }