When the clock source is set to Network, this parameter selects the Trunk ID to be used as the clock synchronization source of the board. When using H.110/H.100 bus, this parameter also selects the trunk used as the clock source for the NetRef clock generation (in this case, the clock source must not be set to Network. Range = 0 to (MAX_TRUNK _NUM-1). Access: Online. AC INI-Param: TDMBusLocalReference
Unsigned32 (0..256)