MIB Viewer

adGenTA8xxSpecificTrapEnable

OBJECT-TYPE
1.3.6.1.4.1.664.5.69.2.6.1.6
Access
read-write
Status
current
Sub-identifiers
0
Enables/Disables specific traps in the TA8xx. 1 = Enabled 0 = Disabled Control is defined as follows: Bits: 0 User Login Success 1 User Login Failure 2 User Lockout 3 DC Power A Fail 4 DC Power B Fail 5 AC Power Loss 6 Ethernet Link Down 7 Ethernet Collisions 15 Minute 8 Ethernet Collisions 24 Hour 9 Ethernet Discarded Frames 15 Minute 10 Ethernet Discarded Frames 24 Hour 11 Ethernet Oversized Frames 15 Minute 12 Ethernet Oversized Frames 24 Hour 13 Ethernet Undersized Frames 15 Minute 14 Ethernet Undersized Frames 24 Hour 15 Ethernet Alignment & FCS Errors 15 Minute 16 Ethernet Alignment & FCS Errors 24 Hour 17 Gigabit Ethernet Link Down 18 Gigabit Ethernet Unapproved SFP 19 Gigabit Ethernet FCS Errors 15 Minute 20 Gigabit Ethernet FCS Errors 24 Hour 21 Gigabit Ethernet Dropped Frames 15 Minute 22 Gigabit Ethernet Dropped Frames 24 Hour 23 Gigabit Ethernet Frames Too Big 15 Minute 24 Gigabit Ethernet Frames Too Big 24 Hour 25 Gigabit Ethernet Frames Too Small 15 Minute 26 Gigabit Ethernet Frames Too Small 24 Hour 27 EFM Group Bad Fragments 15 Minute 28 EFM Group Bad Fragments 24 Hour 29 EFM Group Lost Fragments 15 Minute 30 EFM Group Lost Fragments 24 Hour 31 EFM Group Lost Starts 15 Minute 32 EFM Group Lost Stats 24 Hour 33 EFM Group Lost Ends 15 Minute 34 EFM Group Lost Ends 24 Hour 35 EFM Group Down 36 EFM Group Partial Down 37 EFM Link Errored Fragments 15 Minute 38 EFM Link Errored Fragments 24 Hour 39 EFM Link Small Fragments 15 Minute 40 EFM Link Small Fragments 24 Hour 41 EFM Link Large Fragments 15 Minute 42 EFM Link Large Fragments 24 Hour 43 EFM Link Discarded Fragments 15 Minute 44 EFM Link Discarded Fragments 24 Hour 45 EFM Link FCS Errors 15 Minute 46 EFM Link FCS Errors 24 Hour 47 EFM Link Coding Errors 15 Minute 48 EFM Link Coding Errors 24 Hour 49 EFM Link Down 50 SHDSL Loss of Signal 51 SHDSL Loss of Sync 52 SHDSL SNR Margin 53 SHDSL Loop Attenuation 54 SHDSL ES 15 Minute 55 SHDSL ES 24 Hour 56 SHDSL SES 15 Minute 57 SHDSL SES 24 Hour 58 SHDSL UAS 15 Minute 59 SHDSL UAS 24 Hour 60 SHDSL CVC 15 Minute 61 SHDSL CVC 24 Hour 62 SHDSL LOSWS 15 Minute 63 SHDSL LOSWS 24 Hour 64 Ethernet Rx Multicast Frames 15 Minute 65 Ethernet Rx Multicast Frames 24 Hour 66 Ethernet Rx Broadcast Frames 15 Minute 67 Ethernet Rx Broadcast Frames 24 Hour 68 Gigabit Ethernet Rx Multicast Frames 15 Minute 69 Gigabit Ethernet Rx Multicast Frames 24 Hour 70 Gigabit Ethernet Rx Broadcast Frames 15 Minute 71 Gigabit Ethernet Rx Broadcast Frames 24 Hour 72 DS3 Alarms 73 DS3 15 Minute Thresholds 74 DS3 24 Hour Thresholds 75 DS1 Alarms 76 DS1 15 Minute Thresholds 77 DS1 24 Hour Thresholds 78 DSL Alarms 79 Fan Module Removed 80 Single Fan Failure 81 Multiple Fan Failure Bits 0 is the MSB of the first octet in the octet string. If a trap is a component in a standard trap then the standard trap will take presedence. To generate the specific enterprise trap, the standard trap must be disabled (by setting its bit to 0).
OCTET STRING