adGenVdsl2BandStatusUsMargin

OBJECT-TYPE
1.3.6.1.4.1.664.5.65.1.2.6.1.4
Access
read-only
Status
current
Sub-identifiers
0
Upstream Signal-to-Noise Ratio Margin per Band. This parameter is defined by usable band. The upstream signal to noise ratio margin per band is the maximum increase in dB of the noise power received at the VTU-C such that the BER requirements are met for all bearer channels of the band. The upstream SNR margin per band ranges from -64.1 dB to +63.0 dB with 0.1 dB steps. A value of -64.1 indicates out of range.
Integer32 (-641..630)