MIB Viewer

agentPethFaultStatus

OBJECT-TYPE
1.3.6.1.4.1.4526.11.15.1.1.1.9
Access
read-only
Status
current
Sub-identifiers
0
Describes the error description when the pse port is in fault status. A value of none(0) specifies that the pse port is not in any error state. A value of mpsAbsent(1) specifies that the pse port has detected and absence of main power supply. A value of short(2) specifies that the pse port has detected a short circuit condition. A value of overload(3) specifies that the pd connected to the pse port had tried to draw more power than permissible by the hardware. A value of powerDenied(4) specifies that the pse port has been denied power because of shortage of power or due to administrative action.
INTEGER { none(0), mpsAbsent(1), short(2), overload(3), powerDenied(4) }