MIB Viewer

alaRipngInvalidTimer

OBJECT-TYPE
1.3.6.1.4.1.6486.801.1.2.1.10.12.1.1.1.3
Access
read-write
Status
current
Sub-identifiers
0
Time in seconds that a route will remain active in RIB before being moved to the invalid state. The value must be at least three times the update interval. The defined range of 1 to 360 allows backwards compatibility with older devices which do not enforce the three-times constraint. For newer devices which enforce the three-times constraint with the update interval, the minimum allowed value of the invalid timer is 3.
Integer32 (1 .. 360)