MIB Viewer

aluPtpClockPriority1

OBJECT-TYPE
1.3.6.1.4.1.6527.6.1.2.2.12.1.3.1.9
Access
read-create
Status
current
Sub-identifiers
0
The value of aluPtpClockPriority1 specifies the value of the defaultDS.priority1 data set member defined in IEEE Std 1588-2008. If aluPtpClockProfile is 'g8275dot1-2014 (3)' or, 'g8275dot2-2016 (3)' aluPtpClockPriority1 is set to a value of 128, and cannot be changed. This object can only be modified if aluPtpClockAdminState is set to 'outOfService (3)', otherwise an 'inconsistentValue' error is returned.
AluPtpPriority