aluRS232ControlLeadAlbCts is used to configure the ALB/CTS input lead to an ASSUMED value. For RS-232 and V.35: if local gender is DCE, lead indicates Analog loopback if local gender is DTE, lead indicates Clear To Send For X.21: lead is undefined For RS-530, AlbCts represents RlCts: if local gender is DCE, lead indicates Remote Loopback if local gender is DTE, lead indicates Clear To Send Valid values are 'high', 'low' and 'end-to-end'. This object is not supported on the SAR-H and SAR-Hc systems. 'end-to-end' is valid only for subrate (HCM) speeds and for interface configurations compatible with 'satopSerial'.