MIB Viewer

aluRS232ControlLeadCtsAlb

OBJECT-TYPE
1.3.6.1.4.1.6527.6.1.2.2.2.4.5.1.21
Access
read-create
Status
current
Sub-identifiers
0
aluRS232ControlLeadCtsAlb is used to configure the CTS/ALB output lead to a FORCED value. For RS-232 and V.35: if local gender is DCE, lead indicates Clear To Send if local gender is DTE, lead indicates Analog loopback For X.21: lead is undefined For RS-530, CtsAlb represents CtsRl: if local gender is DCE, lead indicates Clear To Send if local gender is DTE, lead indicates Remote Loopback Valid values are 'high', 'low' and 'end-to-end'. 'end-to-end' is valid only for subrate (HCM) speeds and for interface configurations compatible with 'satopSerial'.
AluRS232ControlLead