aluVoiceSignalingMode configures the channel's signaling mode for E&M or transmission only. This object is valid for em channels only. transmissionOnly is not allowed when any port in the port trio is twoWires. For example, if port 1 is twoWires, then the channels under ports 1, 2 and 3 cannot be set to transmissionOnly. aluVoiceSignalingMode is not allowed to differ from other channels in the port trio. For example, if the channel under port 1 is transmissionOnly, then the channels under port 2 and port 3 must also be transmissionOnly. aluVoiceSignalingMode cannot be changed if a channel-group already exists for the port. Changing to em results in defaulting of aluVoiceFaultSignaling, aluVoiceSignalingLeadE, aluVoiceSignalingLeadM, aluVoiceIdleCode and aluVoiceSeizedCode.
INTEGER { notApplicable (0), em (1), transmissionOnly (2) }