bspePethPsePortExtDetailedStatus

OBJECT-TYPE
1.3.6.1.4.1.45.5.8.1.1.1.4
Access
read-only
Status
current
Sub-identifiers
0
Port Status. Valid values for Harrier: 4,8,9,16. Valid values for CondorPoE: 1-16. The object bspePsePortExtDetailedStatus details the status of the port when pethPsePortDetectionStatus is either deliveringPower(3), fault(4), or otherFault(6). - When the value of pethPsePortDetectionStatus is deliveringPower(3), the value of bspePethPsePortExtDetailedStatus should be a value in the range 1-3 (detailes the discovery scheme that was used to detect the PD that is currently powered). - When the value of pethPsePortDetectionStatus is fault(4) or otherFault(6), the value of bspePethPsePortExtDetailedStatus should be some fault value in the range: 4-15. - When the value of pethPsePortDetectionStatus is *not* deliveringPower(3), fault(4), nor otherFault(6), then the value of bspePethPsePortExtDetailedStatus should be detectionStatus(16). A value of poweredResistiveDiscovery(1) indicates that a PD device was detected on this port using the IEEE 802.3af standard compliant Resistor signature discovery scheme. A value of poweredCapacitiveDiscovery(2) indicates that a PD device was detected on this port using the Capacitive detection scheme. A value of poweredCiscoLegacyDiscovery(3) indicates that a PD device was detected on this port using the CiscoIP detection scheme. A value of invalidPd(4) indicates that a non-PoE device has been detected; no power will be supplied. A value of overloadFault(5) indicates that the port has exceeded its port power limit. A value of underloadFault(6) indicates that the connected PD device needs less power than the port lower power limit. A value of uvovFault(7) indicates that an under-voltage / over-voltage fault has occured. A value of powerManaged(8) indicates that the port is discovered and ready to power up, except that the power manager has not decided to power it up yet. This could be because of a power up delay, or it could be because there is no power available. Port does not supply power in order to keep active higher priority ports. A value of limitOverloadFault(9) indicates that the connected PD device needs more power than the port power limit; no power will be supplied. A value of discoveryDisabled(10) indicates that the port is enabled, but no discovery method has been enabled. A value of unableToResetTps(11) indicates that the TPS2384 (PoE Subsystem) could not be reset. A value of unableToInitializeTps(12) indicates that the TPS2384 (PoE Subsystem) could not be initialized. A value of unitialized(13) indicates that port PoE settings have not beed initialized. A value of nonexistent(14) indicates the port doesn't exist. This is used for the last 24 ports on 24 port systems. A value of otherFault(15) indicates that other fault has occured. A value of detectionStatus(16) indicates that the value of pethPsePortDetectionStatus should be disabled(1), searching(2), or test(5).
INTEGER { poweredResistiveDiscovery(1), poweredCapacitiveDiscovery(2), poweredCiscoLegacyDiscovery(3), invalidPD(4), overloadFault(5), underloadFault(6), uvovFault(7), powerManaged(8), limitOverloadFault(9), discoveryDisabled(10), unableToResetTps(11), unableToInitializeTps(12), uninitialized(13), nonexistent(14), otherFault(15), detectionStatus(16) }