MIB Viewer

cadNtpSourceMaxPollDefault

OBJECT-TYPE
1.3.6.1.4.1.4998.1.1.5.2.3.10.2
Access
read-write
Status
current
Sub-identifiers
0
Default maximum polling interval for NTP clients and peers. This object is expressed is powers of 2 seconds in the range of 4 through 11, for an effective minimum polling interval of between 16 and 2048 seconds. This object may not be set to a value less than cadNtpSourceMinPollDefault. The value in this object is ignored if cadNtpSourceMaxPoll is non-zero.
Integer32 (4..11)