MIB Viewer

ccrForceCounterSync

OBJECT-TYPE
1.3.6.1.4.1.9.9.105.1.1.5
Access
read-write
Status
current
Sub-identifiers
0
This object is used to force the synchronization of counters from primary CPU to secondary CPU. It should generally be set just before a controlled Route Processor Switchover. When this object is retrieved, the value 'noop' is returned. When this object is set to 'noop' no operation is performed.
INTEGER { forcesync (1), noop (2) }