cds1AlarmDownCount

OBJECT-TYPE
1.3.6.1.4.1.9.9.229.1.2.2.1.4
Access
read-write
Status
current
Sub-identifiers
0
This parameter specifies the decrement to the Near End alarm integration counters. The alarms are LOS and LOF. The integration counter is decremented by this value every 100 ms while no alarm persists. The counter does not decrement below zero. When the integration counter reaches zero any Alarm previously declared is removed.
Integer32 (0..2147483647)