MIB Viewer

cldBandSelectCycleCount

OBJECT-TYPE
1.3.6.1.4.1.9.9.612.1.1.9.2
Access
read-write
Status
current
Sub-identifiers
0
This object specifies band select probe mobile station count. Suppressed mobile stations and corresponding suppression count are recorded in a suppression table which is stored in internal database of controllers. AP will suppress probe request of a mobile station till value of cycle count. AP will increment cycle counter when a mobile station scan a channel on 2.4GHz band after any time greater than cldBandSelectCycleThreshold. When a mobile station cycle count is reached and if mobile station still sends a probe request then AP will respond to it by probe response. For example, we assume at minimum, a mobile station will stay in a channel for 5 milliseconds and there are 11 channels. If the mobile station scans channel 1 and then the other 10 channels, there should be at least a gap of 10x5 milliseconds between the last time AP hears the mobile station probe and the latest one. AP only increments the count if the difference of time between the latest and the last probe is more than 50 milliseconds.
Integer32 (1..10)