Remote Insight/ Integrated Lights-Out Action Flags. This is a collection of flags used to indicate the various options available. ResetSupportBit: If bit-0 is set to 1, the option is available. If bit-0 is set to 0, the option is NOT available. iLOAlerts If bit-1 is set to 1, iLO alerts are enabled. If bit-2 is set to 1, iLO alerts are disabled. These two bits should never have the same value. HostAlerts If bit-3 is set to 1, Host alerts are enabled. If bit-4 is set to 1, Host alerts are disabled. These two bits should never have the same value. Bit-31 is used to execute the set operation. NOTE: bit 31 is the most significant bit, bit 0 is the least significant. Status This is a collection of flags. Each bit has the following meaning when it is on (1): Bit 0: Reset Supported Bit 1: iLO Alerts Enabled Bit 2: iLO Alerts Disabled Bit 3: Host Alerts Enabled Bit 4: Host Alerts Disabled Bit 5-30: RESERVED Bit 31: Execute Set