MIB Viewer

cwdxHeSuMaxCpeNumber

OBJECT-TYPE
1.3.6.1.4.1.9.9.169.1.3.7.1.1
Access
read-write
Status
current
Sub-identifiers
0
The maximum number of permitted CPEs connecting to the SU. The value -1 means to use the default value of maximum hosts per SU in the HE wireless interface which the SU connects to and the value is defined in cwdxHeSuDefaultMaxCpes in the cwdxHeMacExtTable. The value 0 means no maximum limit. The default value is -1. Setting the value will not affect the already connected CPEs to the SU.
Integer32 (-1..255)