MIB Viewer

docsPnmCmtsUsImpNoiseEndTrigLvl

OBJECT-TYPE
1.3.6.1.4.1.4491.2.1.27.1.3.4.1.4
Access
read-write
Status
current
Sub-identifiers
0
The measurement of an individual burst event ends when the burst noise falls below the EndTriggerLevel. It is worth noting that if the EndTriggerLevel is set to zero, the FreeRunDuration is set to zero and the Enable attribute is set to true, then at most a single Impulse Noise Event will be recorded when triggered by a burst event exceeding the StartTriggerLevel. This object cannot be changed while a capture is in progress. It will return a value of 'inconsistentValue' if set while the value of 'docsPnmCmtsUsImpNoiseMeasStatus' is set to a value of 'busy'.
Unsigned32