MIB Viewer

docsPnmCmtsUsSpecAnMiniSlotNum

OBJECT-TYPE
1.3.6.1.4.1.4491.2.1.27.1.3.8.1.5
Access
read-write
Status
current
Sub-identifiers
0
This attribute provides a mechanism by which the CMTS can begin the Spectrum Analysis at a subcarrier frequency corresponding to the MiniSlotNumber. This attribute is used when the TriggerMode is MiniSlotNumber. This object cannot be changed while a capture is in progress. It will return a value of 'inconsistentValue' if set while the value of 'docsPnmCmtsUsSpecAnMeasStatus' is set to a value of 'busy'.
Unsigned32 (0..65535)