MIB Viewer

efmCuPmeOperStatus

OBJECT-TYPE
1.3.6.1.4.1.5504.10.1.7.1.2.3.1.1
Access
read-only
Status
current
Sub-identifiers
0
Current PME link Operational Status. Possible values are: up(1) - link is Up and ready to pass 64/65B encoded frames or fragments. downNotReady(2) - link is Down and the PME does not detect Handshake tones from its peer. This value may indicate a possible problem with the peer PME. downReady(3) - link is Down and the PME detects Handshake tones from its peer. init(4) - link is initializing, as a result of ifAdminStatus being set to 'up' for a particular PME or a PCS the PME is connected to. This object is intended to supplement Down state of ifOperStatus. This object partially maps to the Clause 30 attribute aPMEStatus. If a Clause 45 MDIO Interface to the PME is present, then this object partially maps to PMA/PMD link status bits in 10P/2B PMA/PMD status register.
INTEGER { up(1), downNotReady(2), downReady(3), init(4) }