MIB Viewer

eqliscsiSnapCollectionPolicyEndTime

OBJECT-TYPE
1.3.6.1.4.1.12740.5.1.7.25.1.10
Access
read-create
Status
current
Sub-identifiers
0
The value of this object represents the time to stop creating snapshot(s) within a day expressed as number of minutes from 12:00AM. The maximum value for this column is 24*60-1 which represents 11:59PM. If eqliscsiSnapCollectionPolicyType is once or hourly, the value of this column doesn't have any significance. If the value of this column is greater than start time, it represents end-time on the same day as start time. If the value is less than or equal to start time, it represents end-time on the next day of start time. This value doesnt have significance when frequency is set to zero. Endtime is exclusive when calculating no of snapshots. Example: StartTime EndTime Frequency NoofSnapshots 1320(10pm) 1380(11pm) 30mins 2 1320(10pm) 240(4am) 60mins 6 1320(10pm) 1320(10pm) 60mins 24 1320(10pm) 1319(9:59pm) 60mins 24 1320(10pm) - 0mins 1
Integer32 (0..1439)