MIB Viewer

etRptrMonitorTransmitCollisions

OBJECT-TYPE
1.3.6.1.4.1.164.9.1.1.9
Access
read-only
Status
current
Sub-identifiers
0
This counter is incremented every time the repeater state machine enters the TRANSMIT COLLISION state from any state other than ONE PORT LEFT (Ref: Fig 9-2, IEEE 802.3 Std). The approximate minimum time for rollover of this counter is 16 hours.
Counter32